TCB Correspondence

FCC ID: EO960W

Cover Letter(s)

Download: PDF
FCCID_652029

Non-Conformities FCC ID: EO960W (Ref # E06-000090-1)
The items listed below represent requests for information following review of this application. Further question may arise pending review of responses to these
items.

OK    #      Non-Conformity or Comment                                                          Submitted Response                        Respondent / Date of
                                                                                                                                          Response
x     1      Please explain the output power table on page 10 of the test report. The setup     A revised test report has been uploaded   CKC Labs – 4/19/06
             indicates that the alternative method was used employing a calculated output
             power. The table indicates EIRP, but does not seem to list the calculated
             conducted power output of the equipment. Please provide the peak conducted
             power output from the equipment prior to the antenna.
NC    2      Block diagram lists an oscillator directly controlling the RF circuitry at ~       A revised test report has been uploaded   CKC Labs – 4/19/06
-2           26MHz. Please provide demonstration of compliance to the applicable limits
             in accordance with 15.33. Specifically, a loop antenna is not listed in the test
             report as part of the equipment used. Please ensure all test equipment used is
             listed within the test report.
X     3      Please provide a users manual incorporating the statement required by 15.21.       A revised user’s manual has been          CKC Labs – 4/19/06
                                                                                                uploaded
X     4      Page 13 of test report indicates peak emissions with a limit of 74dBuV/m @ 3       A revised test report has been uploaded   CKC Labs – 4/19/06
             meters. This clearly demonstrates compliance to 15.35(b), however the
             equipment is required to demonstrate compliance with average measurements
             to 15.209 within restricted bands above 1000MHz. Please provide data
             demonstrating compliance to the emissions limitations of 15.209 at the proper
             limit.
X     5      Please provide calibration information for all equipment used for testing.         Calibration certifications have been      CKC Labs – 4/19/06
                                                                                                uploaded
X     6      Was testing performed with a fresh battery in accordance with 15.31(e)?            Testing was performed with a fresh        CKC Labs – 4/19/06
                                                                                                battery in accordance with 15.31(e).
X     7      Please declare the frequency range tested in accordance with 15.33.                A revised test report has been uploaded   CKC Labs – 4/19/06
X     8      Test report does not state measurement equipment detector functions and            Measurement bandwidths and detectors      CKC Labs – 4/19/06
             bandwidth. Please provide information in accordance with 15.35.                    are called out in each test set-up and,
                                                                                                where plots are shown, are clearly
                                                                                                visible
NC    9      Please provide demonstration of compliance to 15.247(a)(1)(i), maximum             A revised test report has been uploaded   CKC Labs – 4/19/06
-2           time of occupancy requirements.


Non-Conformities FCC ID: EO960W (Ref # E06-000090-2)
The items listed below represent requests for information following review of this application. Further question may arise pending review of responses to these
items.

OK    #      Non-Conformity or Comment                                                         Submitted Response                       Respondent / Date of
                                                                                                                                        Response
      2      Item 2 still open, The updated test report provided claims frequency range of     Updated test report provided.            CKC Labs 4/27/06
             investigation is 30MHz to 9.2GHz.

             Original NC: Block diagram lists an oscillator directly controlling the RF
             circuitry at ~ 26MHz. Please provide demonstration of compliance to the
             applicable limits in accordance with 15.33. Specifically, a loop antenna is not
             listed in the test report as part of the equipment used. Please ensure all test
             equipment used is listed within the test report.
      9      Item 9 still open: The updated test report does provide time of occupancy         Updated test report provided.            CKC Labs 4/27/06
             plots, however, does not provide a any data to support compliance. Please
             provide evidence of compliance, via calculation or graphical means.

             Original NC: Please provide demonstration of compliance to 15.247(a)(1)(i),
             maximum time of occupancy requirements.

             Text of 15.247(a)(1)(i) “…the average time of occupancy on any frequency
             shall not be greater than 0.4 seconds within a 20 second period…”



Document Created: 2006-04-27 14:28:43