Theory of Operation

FCC ID: EO940GN-1

Operational Description

Download: PDF
FCCID_6964

Automatic Meter Reading Products




     Detailed Descriptions of the
         40GN ERT Module




             ITRON INC.


                                               TABLE OF CONTENTS




INTRODUCTION------------------------------------------------------------------------------------------------------------------- 3
   DATA MESSAGE TRANSMISSION TIMING --------------------------------------------------------------------------------- 3
ERT UNIT RF SECTION DESCRIPTION ------------------------------------------------------------------------------------ 4
   OSCILLATOR (Q1) ------------------------------------------------------------------------------------------------------------------ 4
   RECEIVER ENABLE/DISABLE -------------------------------------------------------------------------------------------------- 4
   TRANSMIT/RECEIVE CONTROL ----------------------------------------------------------------------------------------------- 4
   TRANSMIT FREQUENCY CONTROL ------------------------------------------------------------------------------------------ 5
   TRANSMIT DATA ------------------------------------------------------------------------------------------------------------------- 5
   RECEIVE AUDIO DETECTION -------------------------------------------------------------------------------------------------- 5
LOGIC DESCRIPTION ----------------------------------------------------------------------------------------------------------- 6

SOFTWARE ------------------------------------------------------------------------------------------------------------------------- 7
   COLD-START ------------------------------------------------------------------------------------------------------------------------- 8
   RESET----------------------------------------------------------------------------------------------------------------------------------- 8
   DEBOUNCE (DEBOZ) -------------------------------------------------------------------------------------------------------------- 8
   SLEEP ----------------------------------------------------------------------------------------------------------------------------------- 8
   TRANSMIT ---------------------------------------------------------------------------------------------------------------------------- 8
   RECEIVE MANCHESTER DELAY ---------------------------------------------------------------------------------------------- 9
   PROCESS RECEIVED COMMANDS -------------------------------------------------------------------------------------------- 9
   ACTIVE METER COUNT MODE ------------------------------------------------------------------------------------------------ 9
READONE PRO UNIT PROGRAMMING MODE ------------------------------------------------------------------------ 10

ERT UNIT SOFTWARE TEST MODE ---------------------------------------------------------------------------------------- 12

BLOCK DIAGRAMS -------------------------------------------------------------------------------------------------------------- 13


ITRON INC. 40GN ERT Module Description                           FCCID: EO940GN-1


INTRODUCTION

         Our newest ERT module, the 40GN ERT Unit, represents a significant change from the circuitry
incorporated in our previous gas and electric utility meter reading modules. The electronics have been
upgraded in order to comply with the new FCC emission limits and to address the needs of the water
utility market.
         The 40GN ERT module employs a microcontroller and a custom integrated circuit to allow
communications between a consumptive utility meter and a mobile or handheld meter reader device.
The software-based architecture within an ERT module utilizes on-board firmware, which allows each
unit to be customized for easy installation, field service and interfacing with the billing systems of
virtually all utilities. The customer, via this programming link, cannot alter transmitter power and RF
timing.     Once the wake-up tone, which is unique for each utility, is set and the ERT module is
electronically locked, the customer cannot reprogram any characteristics of the device.               RF
characteristics of the device are not programmable. Only items such as initial meter reading settings,
type and characteristics of the utility meter on which the unit is installed and tamper sensor resets are
programmable by the customer. None of these programmable features affect the RF characteristics of
the ERT module.
         All circuitry resides on a single ceramic substrate (circuit board).     The encoder magnet is
located in an adjacent shaft which essentially performs the same encoding technique as utilized in the
original 40G ERT Unit (FCC ID # EWQ90F2482517-A). Much of the logic circuitry has been integrated
into a custom integrated circuit. This breaks the ERT Unit hardware into two sections, logic and RF,
described in the following sections.


DATA MESSAGE TRANSMISSION TIMING

       When awakened by a coded message from a ReadOne Pro Unit, DataCommand Unit or
DCH-PN Unit, ERT modules transmit a burst of 8 utility usage messages during a 656 msec. period and
repeats the bursts every 11 seconds. Individual messages in the 8-message bursts are just under 6
msec. wide, with a separation of about 88 msec. The quiet time between the 8-message bursts is
about 10.3 seconds.




                                                                                                       3


ITRON INC. 40GN ERT Module Description                            FCCID: EO940GN-1


ERT UNIT RF SECTION DESCRIPTION

        Both the receiver and transmitter sections of a 40GN ERT module share the same basic
oscillator circuit. The receive frequency is tuned to 955 MHz and the transmit frequency range is 910
to 920 MHz. The normal state of an ERT module at rest is "Receive Mode". When in "Receive
Mode", the ERT module continuously monitors for the presence of a coded command to transmit the
current meter reading.       The receiver is always sampling except when commanded to transmit
consumptive utility data.
        The command to transmit data is a coded amplitude modulated (AM) signal in the range of 952
to 960 MHz that is received from a mobile or handheld device. When this signal is detected, the ERT
module switches to the Transmit Mode then transmits a data message eight (8) times. The transmit
frequency of each of the eight (8) messages is randomly selected within the ERT module from among
the 31 frequencies available between 910 and 920 MHz. This method of operation improves the ability
of the mobile or handheld data collection device to successfully read the consumptive utility usage data
because the chance of two or more ERT modules transmitting at the same time and at the same
frequency is significantly reduced.


OSCILLATOR (Q1)

         The design is based on a Colpitts Oscillator (refer to Figure 1) consisting of Q1, C2, C3, C4,
C5, C11, C12, C15, CR2, and a tuning stub and microstrip antenna which is connected to the
collector of Q1. Capacitors C4 and C5 control the positive feedback which is necessary to sustain
oscillation. The microstrip antenna provides tank circuit inductance to resonate with the capacitances
C3 and C11 to provide a coarse frequency adjustment by capacitively loading the microstrip. The
tuning stub offers a means of fine tuning the oscillator receive frequency. CR3 is a PIN diode which
enables C12, CR2, and C15 to shift the ERT Unit frequency into the transmit band. C12 (a laser
trimmable capacitor) provides the fine-tuning of the ERT into the transmit band.
         Q1 is a PNP transistor. By using this bipolar technology, the driving logic that is tuned in the
previous version 40G can be used without modification. Also, this choice enables the antenna to be at
ground potential nearly all of the time. (The implications into migration can be easily recognized.)
         R2, R3, R4, R5, and CR1 provide a temperature compensated bias current into Q1 for both
receive and transmit operation. C2 is a 900 MHz bypass for the base. C1 contours the current
ramping of Q1 for receive operation, while C6 effectively disables this ramp action to occur in transmit
mode. R4 and C6 control the transmit power of the unit.


RECEIVER ENABLE/DISABLE

        In receive mode, the oscillator is switched on and off by the logic of U51. When pin 17 goes
low, a ground return is provided through R2 for a base voltage ramp to begin. R5 turns this changing
base voltage into an increasing current through Q1. When pin 17 goes high, Q1 is disabled. R2, R3,
R5, C1 and CR1control the characteristics of the ramping current.


TRANSMIT/RECEIVE CONTROL

       The tank circuit is changed to allow the frequency to shift from the receive band to the transmit
band at 910 - 920 MHz. This frequency change is controlled by the opposite logic of pin 19 of U51 and
pin 18 of U52. Acting differentially on CR3, these pins negatively bias CR3 with full supply voltage in


                                                                                                       4


ITRON INC. 40GN ERT Module Description                             FCCID: EO940GN-1
receive, or forward bias CR3 through R8 in transmit. The forward biasing of CR3 enables C12, CR2,
C15, and LI, thus lowering the oscillation frequency of Q1 into the transmit band.


TRANSMIT FREQUENCY CONTROL

        The transmit frequency is varied within 910 to 920 MHz by the DC voltage on pin 22 of U51.
This voltage can be changed in 31 steps from approximately 0 to about 1.6 volts. The voltage on pin
22 is applied to one side of varactor diode CR2. Note: The upper voltage value on the anode of CR2 is
determined by voltage division between R11 and the output impedance of pin 22 of U51. This output
impedance has a part to part distribution of values.          The voltage swing on the varactor, and
consequently, the distribution of transmit frequencies will reflect that source of variability. Higher
voltages on the anode of the varactor results in a lower frequency in the transmit band.


TRANSMIT DATA

       Data messages are Manchester-encoded and contain the unit ID number, gas meter reading,
and other information. The data is transmitted using on and off keying of oscillator Q1. The transmit
data output is pin 16 of U51. When this output goes low, oscillator Q1 is enabled by establishing a
base voltage through the base circuit components. When pin 16 goes high, the oscillator is disabled.
Therefore, a logic 0 output on pin 16 represents presence of carrier, and a logic 1 represents the
nonexistence of carrier.


RECEIVE AUDIO DETECTION

        In the receive mode this circuit functions as a super regenerative detector. The principal of
detection is to mark the time that it takes the oscillator to start up. Within-band RF energy present on
the antenna, this energy will promote the starting up of the ERT Unit oscillator. This will cause the
oscillator to turn on at a lower current level. Since throughout the RX enable time frame the current
through Q1 is ever increasing, starting up at a lower current level equates to starting up sooner. The
time to oscillator startup is monitored by the electronics in U51. If this timing varies at a rate equal to
the programmed wakeup tone, the ERT will go into its transmit routine.




                                                                                                         5


ITRON INC. 40GN ERT Module Description                           FCCID: EO940GN-1


LOGIC DESCRIPTION

        The RF section shown in block diagram in Figure 2, is controlled by the custom IC, U51. This
device is designed specifically for the ERT Unit. It includes EEPROM memory for the ID number, RAM
for storing programmed parameters, tone demodulator circuitry, three logic level output ports, latches
for count and theft inputs, the master oscillator running at 32.768 kHz and a Digital to Analog converter
to provide the tuning voltage for the RF transmit frequency.
        U51 is controlled via a "micro-wire" interface by the microprocessor, U52, which is a masked
device containing the 40GN software. In turn, however, U51 controls the clock of U52, which is cycled
at one of two rates depending on the activity to be performed. The interface bus is used by U52 to
communicate control instructions to and status register information from U51. Several other status
lines on U51 are controlled or read by U52.
        Inputs or count, tilt and magnetic theft detectors are fed simultaneously to both U51 and U52.
These normally low inputs are sampled under software control to reduce the current drain in the event
that a switch remain closed to battery voltage for extended time.
        Referring again to Figure 1, the CKI clock input, pin 5, U52, is held low, causing U52 to be
inactive, until U51 detects input or a valid wake-up tone. An active input condition causes U51 to
assert the CKI clock line at 32.768 kHz. Once active, U52 becomes the system master controlled by
the clock provided by U51. Besides detecting input conditions, U51 functions as the RF interface.
Data demodulated from the receiver enters U51 at pin 12, is output from RX_DATA_OUT on pin 11 of
U51, and finally is presented as a digital signal at pin 11 of U52. Information to be transmitted is sent
from U52 to U51 via the micro-wire interface.




                                                                                                       6


ITRON INC. 40GN ERT Module Description                             FCCID: EO940GN-1


SOFTWARE


       The controlling program, written in ''C", is resident in U52 when it is manufactured. Refer to the
flow chart in Figure 3. The program consists of three Modes:
       I)       Test Mode, for initial tune up,
       2)       Program mode, for setting options and,
       3)       Active Meter mode, usual ERT Unit operation.

       The software has seven major routines that perform the ERT Unit functions:
       1)     Cold Start Initialization
       2)     Reset,
       3)     Deboz (debounce),
       4)     Sleep,
       5)     Transmit,
       6)     Receive Delay and
       7)     Process Commands.

        An overall flow sequence between the custom, U51, and the controller, U52, can be described
for the normal operation of the ERT Unit. The terms "SLEEP" and "HALT" are used interchangeably in
the following discussion and indicate the period when the microprocessor is not active. Fast Start
refers to the transmit/receive data mode, TRANSMIT, which requires a faster than normal CKI clock
input. The general sequence for U52/U51 interaction is:


       0.     U52 clock line stopped, U51 inputs inactive.
       1.     U51 detects an active input or wake-up tone.
       2.     U51 turns on U52 clock and asserts Reset.
       3.     U52 starts at PC= #00, determines start mode.
       4.     U52 reads U51 status.
       5.     U52 executes appropriate process.
       6.     U52 tells U51 to shut off the clock.
       7.     U51 stops clock.
       8.     U51 waits for active input.



Governing priorities for the sequences above are:
       1.      Record Consumption Data.
       2.      Detect Wake-up Tone and Transmit Standard Message.
       3.      Record Tamper Detection.
               A.        Magnetic
               B.        Cable*
               C.        Displacement*
               D.        Tilt
       4.      Receive and process ReadOne PRO Unit Commands

              *Not Currently Implemented




                                                                                                       7


ITRON INC. 40GN ERT Module Description                             FCCID: EO940GN-1


COLD-START

        This is the power-up reset routine. The first time battery power is applied, the custom IC control
blocks and controller RAM space is loaded with default values. A copy of the last byte sent to each
control block is also kept in RAM, (except for TXDAT, and EEPRM data). The Controller clock is
placed in Fast Mode to facilitate a quick power-up sequence.


RESET

        The custom IC chip will assert the Controller's reset line any time the µC CLOCK line changes
state. Specifically, three conditions will result in a controller reset: Initial Power-up; Activation of any
custom IC Status Flag during Sleep Mode; Change in µC Clock frequency. A general initialization of
ports and registers must occur after any reset. Three RAM bytes are tested for pre-initialization.
Failure of any of these bytes to match results in a Cold Start. A one-byte checksum is performed over
the consumption data and compared to the last stored value. Failure to match causes a jump to
WCHDG. A fourth RAM byte test determines if a general warm start or a fast start is followed.


DEBOUNCE (DEBOZ)

        DEBOZ is the debounce routine executed during any warm start, or called as a subroutine
during Tx/Rx mode. A RAM flag indicates how DEBOZ has been entered. Two successive custom IC
status reads are required to determine a valid input edge. The first read clears the custom IC status.
If the status remains cleared until the second read, a valid edge is determined. The Tilt Tamper line
must maintain a steady level for the programmed amount of time before its level is determined. This
loop will continue until a wake-up tone causes a branch to TONAK, or until the custom IC status
becomes inactive.


SLEEP

Send HALT command to custom IC. If the tilt debounce counter is active, control jumps back to
DEBOZ. If custom IC status bits are still asserted, jump to Warm Start to process them.


TRANSMIT

        TRANSMIT oversees the RF transmission of data messages. The controller clock speed has
been increased to accommodate timing requirements. The speed change caused U52 to reset U51.
After determining that the clock is fast, the RESET routine has branched control here. A 40 ms delay
is provided to setup the circuits prior to sending data. The meter counts may be updated at this time to
speed up slow clock functions.




                                                                                                          8


ITRON INC. 40GN ERT Module Description                           FCCID: EO940GN-1


RECEIVE MANCHESTER DELAY

       This routine enables a 512 Hz interrupt and then enters a sit-and-spin loop. The loop does
nothing more than repetitively poll DEBOZ to check for input activity. The 512 Hz interrupt routine
attempts to decode manchester data emanating from custom IC pin 11 and store it into RXBUF, a 12
byte buffer. Loop exit occurs when the loop delay expires, or if a valid ERT Unit ID has been received.
RXINT is responsible for setting the appropriate flag.


PROCESS RECEIVED COMMANDS

        This is really a group of subroutines that do internal decoding and control functions based on
information received. It is also where the majority of the arithmetic operations are done to incorporate
the options programmed into the unit.


ACTIVE METER COUNT MODE

        Assuming an Initialized ERT Unit is in Halted mode and the Custom IC Chip is actively sensing
condition changes:

              Custom IC Chip (U51):
                    Active Input is detected.
                    Associated Status register bit is set.
                    Controller Reset line is asserted.
                    U52 Controller clock enabled at 32.768 KHz.

              Controller (U52):
                     Program execution begins at PC = #00
                     General registers, micro-wire initialized.
                     RAM test reveals Warm Start condition.

              Jump to DEBOZ routine to debounce inputs.
                    Input pins sampled
                    If Falling edge of Count input, JSR UPCNT
                    If Tone_Det, JMP TONAK
                    If Tilt enabled and active, start tilt timer
                    If Mag. Tamper enabled and edge detected, JSR UPMAG
                    Otherwise send HALT command to custom IC

              Custom IC chip (U51):
                    Stop controller's clock input.
                    Continue sensing input and wake-up conditions.




                                                                                                      9


ITRON INC. 40GN ERT Module Description                       FCCID: EO940GN-1


READONE PRO UNIT PROGRAMMING MODE

        One task of the ERT Unit is to read and respond to the commands of the ReadOne PRO Unit
programmer. The ERT Unit must receive its program variables from the ReadOne PRO Unit and
output data when requested. Assuming an initialized ERT Unit is in halted mode, actively sensing
conditions, the program steps are:

      ReadOne PRO Unit:
           Transmits Wake-up tone.

      Custom IC Chip (U51):
            Detects tone, asserts TONE_DET status Flag,
            Enables U52 Clock, 32.768 KHz, resets U52.

      Controller (U52):
             Begins code execution at PC=#00
             Custom IC Status is read/Input flags are reset
             FAST-CLK-ENABLE sent to U51 to speed up clock

      Custom IC Chip (U51):
            Increase U52 Clock frequency to 786.4 KHz
            Assert U52 Reset.

      Controller (U52):
             Code execution begins at PC= #00
             Program branches to TRANSMIT routine
             Transmit Buffer loaded with Consumption Data
             LOOP 8 Times:
                     Randomly tune transmit frequency.
                     DEBOZ polls inputs, updates counters.
                     DELAY called to delay 50 ms.
                     DEBOZ polls inputs, updates counters.
                     DELAY called to delay 50 ms.
                     Control to 10 S RCVDLY receive/delay loop.

      ReadOne:
           Receives Standard Consumption Message
           Transmits Command message

      Controller (U52):
             RCVDLY clears RXBUF and 512 Hz timer.

      Delay Loop:
             DEBOZ samples inputs, updates counters.




                                                                                               10


ITRON INC. 40GN ERT Module Description                           FCCID: EO940GN-1


     During Delay Loop:
            RXINT interrupts delay loop 512 times/sec.
            RXDLY counter is decremented
            If RXDLY reaches zero, Time_ Expired flag set
            Custom IC RX_ DATA pin sampled
            Decoded bits shifted into RXBUF
            Test for Valid ERT Unit ID and sets flag
            If Time_ Expired, or Valid_ ID interrupts disabled.
            If no Valid_ID, jump to SLOW

     RSPND code block called when Valid_ID detected.
          Received data copied into RXMSG buffer
          RXBUF data prepared for CRC, (strip ID,CRC)
          CRC calculates checksum of received message.
          Calculated CRC compared to Received CRC
                 If not equal, jump back to RXDLY for remainder of 10 seconds.
          RXBUF.CMD command field tested for range
                 The interrogation commands do not test for Utility ID.

     Response transmitted to all commands except CMD7.
     RCVDLY reentered after transmitting the response.
     Continue receiving and responding to commands.
     IF "End of program" is received
            delay 5 minutes, setting the LOCK and Wake-up Tone,
            Jump to SLOW to return clock to 32.768 KHz.

     Custom IC Chip (U51):
           U52 Clock line is returned to 32.768 KHz
           U52 Reset line is asserted

     Controller (U52):
            Program begins at PC= #00
            RESET reads Custom IC Input Status
            RESET reads Custom IC W.D., and TONE_DET status
            SLEEP called if no activity
            SLEEP finally sends HALT command to Custom IC

     Custom IC Chip (U51):
           U52 Clock line is halted.
           Clock will not stop if a status bit is set.




                                                                                     11


ITRON INC. 40GN ERT Module Description                        FCCID: EO940GN-1


ERT UNIT SOFTWARE TEST MODE

       The software in the ERT Unit provides an input command that allows two test modes for initial
frequency alignment and verification testing of the encoder. Test Mode is entered by sending CMD7,
Test Mode, from the ReadOne PRO Unit.

       Test Mode Command, CMD7, provides two test modes:

              Test 1.       Transmit Low, Mid-band, and High Frequency.
                                  Then return to SLEEP.

              Test 2.       Shift ERT from Rx to Tx Mode while Count Switch is active. The time
                                   looping within test mode 2 = 0.3 S * [DURATION].           Where
                                   DURATION is a 8 bit field supplied within the CMD7 syntax.

       Upon receiving the appropriate command from the ReadOne PRO Unit, the ERT Unit will follow
these steps:

       TEST MODE #1

              - IF RXBuf Mode =#1
                     THEN transmit 12 bytes of all '00'
                           Once at Lowest frequency
                           Once at Mid frequency
                           Once at Highest frequency
              jump SLEEP

       TEST MODE #2

              - IF RxBuf.test =#2 THEN
                     [LoopCNT] <= RxBuf.Duration
                             WHILE [LoopCNT] > 0
                             IF (Meter count Reed switch = Active)
                                    THEN (Program Custom IC for Tx Mode)
                                    ELSE (Program Custom IC for Rx Mode)
                             Decrement Counter
              jmp TRANSMIT




                                                                                                 12


ITRON INC. 40GN ERT Module Description   FCCID: EO940GN-1
Block Diagrams




                                                             13


ITRON INC. 40GN ERT Module Description                         FCCID: EO940GN-1




                                                                                 RF
                 COP842                             HUGHES                     SECTION
               CONTROLLER         ΦC CLOCK         CUSTOM IC
                                                                 DATA IN
                                   RESET
                2048 CODE
                  BYTES           RX'D DATA

                              COMMUNICATION LINK
                                                                  DATA OUT
                # DEFAULTS                          Tx DATA

                                                    TONE DET
               PROGRAMMABLE
                                                    Tx FREQ.      RF CONTROL
                 VARIABLES
                                                   RF CONTROL
               METER COUNTS
                                                    EEPROM

               TAMPER DATA                         CLR START
                                                    STATUS


                   U 52                              U 51




               Meter Count

                Tilt Tamper


               Mag Tamper



                              40GN Block Diagram

                                    FIGURE 2




                                                                                         14


ITRON INC. 40GN ERT Module Description                                                                          FCCID: EO940GN-1



                                  RESET
                             Initialize COPS
  RESET
                            Control Registers
                            & External Parts                           RESET Macro



                     YES                        NO                        NO
                                 COLD                   CHKSM                         JSR
  COLD
                                 START                   OK                          WCHOG


                                                                  YES


           COLD START                                   WARM                NO       FIRST          NO    JMP
          INITIALIZATION                                START                        MODE                COLD



                                                                  YES                     YES

                                DEBOZ


                                                                       DEBOZ MACRO & SUBROUTINE


                                                      DEBOUNCE
              JMP                                                                                               TRANSMIT
                                                        & POLL
             RESET
                                                       INPUTS

                                                                                                                              RCVDLY Macro



                                                                                                                RECEIVE
                                                                            YES        Speed-up
                                                        TONE                                                     DELAY
                                                                                        Clock
                                                       DETECT                                                    LOOP
                                                                                      Set Tx tage


                                                               NO                                                                       PROCESS
                                                                                                                                        COMMAND
                           SLEEP

                                                                  SLEEP MACRO                                                YES
                                                                                                                  Valid
                                                                                         JMP                    Received
                                                                                        RESET                     Msg
                                                          Tilt            YES
                                                       Debounce
                                                        Active
                                                                                                                        NO


                                                             NO                                            NO
                                                                                                                  Delay
                                                                                                                 Elapsed
                                                         Huges           YES            JMP
                                                         Inputs
                                                                                       DEBOZ                                 YES
                                                         Active

                                                                                                                 SLOW
                                                             NO                                                 controller
                                                                                                                  clock

                                                        SLEEP
                                                     Stop controller
                                                         clock



                                                                                                                  JMP
                                                                                                                 RESET

                                                     40GN SOFTWARE FLOW
                                                                        FIGURE 3




                                                                                                                                                  15



Document Created: 2001-07-13 16:49:50