Maximum Permissible Exposure (MPE)
Determine the maximum power density for the general / uncontrolled population minimum
separation distance of 20 cm.
FCC Limit: f > 1500 MHz = 1mW/cm2; IC Limit: f=1500 to 15000 MHz = 10W/m2
The power density is calculated as:

                                                    Pt G
                                            Pd !
                                                   4 " r2

           Pd = power density in milliwatts/cm2
           Pt = transmit power in milliwatts
           G = numeric antenna gain
           r = distance between body and transmitter in centimeters.

Other Technical Information:
  Antenna Type: Omni
  Antenna Gain: 1 (0dBi)
  Transmitter Power (Conducted): 30mW
  Frequency: 2440 MHz




results:      PD = (30x 1) / ( 4 x pi x 20cm2) =0.00597mW/cm2= 0.0597W/m2 @ 20 cm