                                                                    Installing the 2.4GZ OpenWay Gas Module



                     •   If the index wriggler has a drive post (1), place the index wriggler's drive post
                         in the backplate wriggler's drive slot (2).


                                                                       1




                                                                       2




                                  WARNING! Failure to place the drive post into the drive slot can cause binding
                                  and lead to poor registration or meter failure



              9. Install and tighten the left-hand index mounting screw (for indexes with either
                 mounting screw slots or holes). Use one 8 - 32 x 3/16-inch screw for this step (you
                 can use an original mounting screw if it was the correct size and not corroded;
                 otherwise, use the correct size replacement screw).




              10. Tighten the right-hand index mounting screw.
              11. Slide the OpenWay Gas Module cover (1) over the index and backplate (2).




2.4GZ OpenWay Gas Module Installation Guide                                                                  15


Chapter 2 American Meter Installation




                    Next, program the OpenWay Gas Module.


              Program the OpenWay Gas Module
              Once the OpenWay Gas Module has been assembled, the module must be programmed
              using FieldPro on a laptop with a ZigBee dongle. Refer to FieldPro documentation for
              programming information.

                          IMPORTANT You must perform the following programming procedure for
                          the OpenWay Gas Module to function properly.

              When programming the OpenWay Gas Module, you must take note of the drive rate shown
              on the index of American meters.




16                                                           2.4GZ OpenWay Gas Module Installation Guide


                                                                  Installing the 2.4GZ OpenWay Gas Module



             Examples of 1-foot (1) and 2-foot (2) drive rates are shown below (a 0.05 cubic metre drive
             rate is not shown). Be sure to program the OpenWay Gas Module based on the drive rate
             indicated on the index.




                                              1




                                              2




             To Program the OpenWay Gas Module
              1. Make sure the 2.4GZ OpenWay Gas Module is within 10 feet of the programming
                 device.
              2. Verify that the programming software is running.
              3. Verify that red LED on ZigBee dongle is on.
              4. Hold the magnet under the 2.4GZ OpenWay Gas Module for 5 seconds and then
                 remove it. You will see three red blinks from the LED. This signifies that the 2.4GZ
                 OpenWay Gas Module is searching for a programming device. Within a few seconds
                 the red LED will blink five more times. The programming device will indicate
                 programming success or failure.
                   a) If five red LED blinks are not seen on the 2.4GZ OpenWay Gas Module, hold the
                      magnet under 2.4GZ OpenWay Gas Module for 5 seconds.


2.4GZ OpenWay Gas Module Installation Guide                                                           17


Chapter 2 American Meter Installation



                     b) If 5 red LED blinks are seen on the 2.4GZ OpenWay Gas Module, but the
                        programming device indicates that programming failed, verify the following (1)
                        2.4GZ is within 10 foot range of programming device and (2) programming
                        software is using correct security key. Repeat holding magnet under 2.4GZ for 5
                        seconds.
              When the 2.4GZ OpenWay Gas Module has been programmed to normal mode, it is ready
              to commission to an OpenWay CENTRON meter. If an OpenWay CENTRON meter is
              within range of the 2.4GZ OpenWay Gas Module, the red LED on the 2.4GZ OpenWay Gas
              Module will blink three times, indicating that it is looking for all available OpenWay
              CENTRON meters.

              After choosing the OpenWay CENTRON meter with the best signal, the 2.4GZ OpenWay
              Gas Module will blink five times to indicate successful commissioning to the meter. The
              timing for this could be as quick as one second after being programmed. If within two
              minutes of successful programming, the five blinks are not seen, make note of the
              installation for further investigation.

                       NOTE Itron will be moving to this programming solution in 2008



                1. Using the FC200 and Belt Clip radio, program the reading of the index that was on the
                   meter into the OpenWay Gas Module assembly.
                    During programming, the OpenWay Gas Module is programmed to the nearest 100
                    cubic feet; the last two digits (the tens and units) are programmed as zeros (0). Once
                    programming is complete, however, the OpenWay Gas Module assembly can be read
                    to the nearest cubic foot.
                2. Slowly turn the OpenWay Gas Module drive wriggler two turns in the direction
                   indicated on the index drive rate. This lets you verify the module is counting properly
                   after assembly.


                                IMPORTANT Do not turn the drive wriggler faster than one turn per second.




18                                                             2.4GZ OpenWay Gas Module Installation Guide


                                                                  Installing the 2.4GZ OpenWay Gas Module



              3. Read the OpenWay Gas Module assembly using the FC200 and Belt Clip radio.
                 Consult the EndPoint-Link Programming Guide or other applicable instructions for
                 details on how to read an OpenWay Gas Module.
                     •   If this reading is higher than the one you programmed in step 1 above, the
                         module assembly is counting correctly.
             If the OpenWay Gas Module assembly reading is not higher than what was programmed in
             step 1, replace the module with a new one.




2.4GZ OpenWay Gas Module Installation Guide                                                           19


Chapter 2 American Meter Installation




              Attach the OpenWay Gas Module to the Meter
              After the 2.4GZ OpenWay Gas Module has been programmed and is reading correctly,
              follow the steps below to attach it to the meter.

              To attach the 2.4GZ OpenWay Gas Module to the meter
                1. For 5B 225 Meters Only: If you are installing the OpenWay Gas Module on a 5B
                   225 aluminum meter, cut 1/16-inch off each post of the module wriggler to prevent it
                   from rubbing on the face of the nut that holds the wriggler in place. If you are not
                   installing on a 5B 225 meter, continue to step 2 below.




                2. Set the wriggler to the desired position for mounting the OpenWay Gas Module
                   assembly to the meter.
                       •   For One-Foot Meters: Align the OpenWay Gas Module assembly wriggler
                           with the meter drive post (as shown below). Make sure the wriggler is
                           perpendicular to the meter drive post.




20                                                            2.4GZ OpenWay Gas Module Installation Guide


                                                                  Installing the 2.4GZ OpenWay Gas Module



                     •   For Two-Foot Meters: Align the OpenWay Gas Module assembly wriggler
                         with the meter drive slot (as shown below). It is acceptable for the pin on the
                         module wriggler to be installed inside or outside of the meter drive slot. For
                         ease of assembly, Itron recommends that the pin on the OpenWay Gas Module
                         wriggler be installed outside of the meter drive slot.




              3. Gently place the OpenWay Gas Module assembly on the meter. Align the four screw
                 holes on the module assembly with the holes on the meter.




              4. Turn each screw 1/4 to 1/2 turn after it contacts the cover. Use the 1/4 - 20 x 5/8-inch
                 screws for this step. You can use the original mounting screws if they were the correct
                 size and not corroded, otherwise, use the correct size Replacement Screws on page 7.


                           IMPORTANT Meter manufacturers should torque the mounting screws 15 to 20
                           inch-pounds.




2.4GZ OpenWay Gas Module Installation Guide                                                            21


Chapter 2 American Meter Installation




                                    3                 2

                                    1                 4




                5. Place a new tamper seal over two of the mounting screws as shown below.




                            2

                                                1




                6. Press the new tamper seals into place using the 11/32-inch nut driver (or another
                   similar blunt tool).




                7. Complete any necessary paperwork. Make sure no excess material is left on the
                   customer premises; dispose of it properly.




22                                                             2.4GZ OpenWay Gas Module Installation Guide


                                                               Installing the 2.4GZ OpenWay Gas Module



                  The OpenWay Gas Module is now installed on the meter.




             Waking Up the 2.4GZ OpenWay Gas Module
             You can use an Itron magnet (part number MSE-0159-003) to wake up the 2.4GZ
             OpenWay Gas Module.

             To wake up the 2.4GZ OpenWay Gas Module
              1. Place the magnet under the index cover with the arrow on the magnet pointing up
                 toward the cover.




2.4GZ OpenWay Gas Module Installation Guide                                                        23


Chapter 2 American Meter Installation



                2. Slide the magnet back toward the 2.4GZ OpenWay Gas Module backplate until it is
                   within a 1/4-inch of the backplate.




                3. Hold the magnet there for five seconds to wake up the 2.4GZ OpenWay Gas Module.




24                                                          2.4GZ OpenWay Gas Module Installation Guide


CHAPTER 3

Sensus Meter Installation

             This chapter shows you how to install a 2.4GZ OpenWay Gas Module on a Sensus meter.
             The instructions in this chapter apply to 11-tooth, 16-tooth, and 18-tooth Sensus endpoints.


Installation Prerequisites
             The following items are required to install the Itron 2.4GZ OpenWay Gas Module.


             Materials Supplied By Itron
             The following items are supplied by Itron:
              •   2.4GZ OpenWay Gas Modules
              •   New tamper seals


             Materials Supplied By You
             You must supply the following items to install, initialize, and check the 2.4GZ OpenWay
             Gas Module on the meter.
              •   Small and medium flat-blade or Phillips screwdrivers Used to remove and tighten
                  index and index-cover screws.
              •   Side-cutting plier/wire snips Used for cutting wire seals, if necessary.
              •   Small putty knife Used to remove all traces of old gaskets from the meter.
              •   Meter seals, wire seals, and seal press Used to secure the meter from tampering, if
                  necessary.
              •   11/32-inch nut driver or other blunt tool Used to securely seat new tamper plugs
                  over screw holes.
              •   Replacement screws Used to mount 2.4GZ OpenWay Gas Module assembly to
                  meter and index to module assembly backplates.


             Replacement Screws
             Replacement screws used in this procedure are shown below.

             For mounting 2.4GZ OpenWay Gas Module assemblies on meters:
              •   Use 10 - 24 x5/8-inch slotted, Fillister head screws.
             For mounting indexes on 2.4GZ OpenWay Gas Module backplates:
              •   Use 6 - 32 x 5/8-inch slotted, round head screws.



2.4GZ OpenWay Gas Module Installation Guide                                                             25


Chapter 3 Sensus Meter Installation




              Preinstallation Preparations
              Before installing the 2.4GZ OpenWay Gas Module on a meter, verify that:
                •   All Itron gas modules are 2.4GZ OpenWay Gas Modules for your brand of gas
                    meters.
                •   The model numbers of all meters on which the 2.4GZ OpenWay Gas Modules will be
                    installed are included in the Meter Compatibility List.


Installing the 2.4GZ OpenWay Gas Module
              There are four major steps to installing the 2.4GZ OpenWay Gas Module on a meter:
                •   Remove the index
                •   Assemble the 2.4GZ OpenWay Gas Module
                •   Program the 2.4GZ OpenWay Gas Module
                •   Attach the 2.4GZ OpenWay Gas Module to the meter.
                              NOTE Properly dispose of all unused screws, old index covers, gaskets, tamper
                              seals, and other left-over materials. Do not leave any materials on customer
                              premises.




              Remove the Index
              The first major step when installing a 2.4GZ OpenWay Gas Module on a Sensus meter is to
              remove the existing index from the meter.

              To Remove the Index
                1. Remove any tamper seals from the meter.
                2. Detach the index cover from the meter by removing the four screws holding it in
                   place.



                                      4                     2




                                      1                     3




26                                                              2.4GZ OpenWay Gas Module Installation Guide


                                                                   Installing the 2.4GZ OpenWay Gas Module



              3. Examine the index cover screws you just removed. Verify that they are 5/8-inch long
                 and are not corroded.
                     •   If the screws are 5/8-inch long and are not corroded, keep them for later use.
                     •   If they are an incorrect length or are corroded, dispose of them properly. Use 10
                         - 24 x 5/8-inch screws as described in Replacement Screws on page 25 instead.
                                    TIP You can use the index cover you just removed as a temporary storage
                                    location for screws.
              4. Unscrew one index mounting screw completely.




              5. Remove the other index mounting screw.
              6. Set the index aside for the moment. Place it where it will not be damaged; get filled
                 with dirt, rain or snow; or fall to the ground or floor. The index will be used later in
                 this procedure.
              7. Examine the index screws you just removed. Verify that they are 5/8-inch long and
                 are not corroded.
                     •   If the screws are 5/8-inch long and are not corroded, keep them for later use.
                     •   If the screws are an incorrect length or are corroded, dispose of them properly.
                         Use 6 -32 x 5/8-inch screws as described in Replacement Screws on page 25
                         instead.




2.4GZ OpenWay Gas Module Installation Guide                                                                 27


Chapter 3 Sensus Meter Installation



                8. Use a putty knife or similar object to completely remove the old index gasket from the
                   meter (if applicable). All traces of the gasket must be removed before the OpenWay
                   Gas Module can be installed.




              Assemble the OpenWay Gas Module
              When installing a 2.4GZ OpenWay Gas Module, the next major step is to create the
              OpenWay Gas Module assembly by combining the module backplate and cover with the
              meter index. Follow the procedure below to do so.

              To Assemble the OpenWay Gas Module
                1. Obtain a new 2.4GZ OpenWay Gas Module.
                2. Separate the OpenWay Gas Module backplate from the cover.
                3. Place the index drive gear (1) in the backplate wriggler gear cup (2) of the OpenWay
                   Gas Module (please note that the following example uses an 11-tooth drive gear; your
                   index may have a 16- or 18-tooth drive gear, and you must use the appropriate 2.4GZ
                   OpenWay Gas Module for your specific meter. See the Meter Compatibility list on
                   page 2 for more information).




28                                                             2.4GZ OpenWay Gas Module Installation Guide


                                                                  Installing the 2.4GZ OpenWay Gas Module



                  Once properly in place, the index drive gear and backplate wriggler cup should look
                  similar to the following example.




              4. Attach the right-hand mounting screw to the index and meter, just far enough to hold
                 the index in place. Use one 6 - 32 x 5/8-inch screw for this step (you can use an
                 original mounting screw if it was the correct size and not corroded; otherwise, use the
                 correct size Replacement Screw see "Replacement Screws" on page 25).


                              1                 2




              5. Install and tighten the left-hand index mounting screw.




              6. Tighten the right-hand index mounting screw completely.



2.4GZ OpenWay Gas Module Installation Guide                                                             29


Chapter 3 Sensus Meter Installation



                7. Slide the OpenWay Gas Module cover over the index and backplate.
                8. Verify that the cover is installed correctly.




                    Once combined, the OpenWay Gas Module backplate, meter index, and OpenWay
                    Gas Module cover create an OpenWay Gas Module Assembly.
              Next, program the OpenWay Gas Module.


              Program the OpenWay Gas Module
              Once the OpenWay Gas Module has been assembled, the module must be programmed
              using FieldPro on a laptop with a ZigBee dongle. Refer to FieldPro documentation for
              programming information.

                          IMPORTANT You must perform the following programming procedure for
                          the OpenWay Gas Module to function properly.

              When programming the OpenWay Gas Module, you must take note of the drive rate shown
              on the index of Sensus meters. Sensus meters have a 2-foot drive rate, as indicated in the
              example below (1), or a 0.05 cubic metre drive (not shown).




                                                         1




30                                                                 2.4GZ OpenWay Gas Module Installation Guide


                                                                  Installing the 2.4GZ OpenWay Gas Module




             To Program the OpenWay Gas Module

                     NOTE Itron will be moving to this programming solution in early 2008



              1. Using the FC200 and Belt Clip radio, program the reading of the index that was on the
                 meter into the OpenWay Gas Module assembly.
                  During programming, the OpenWay Gas Module is programmed to the nearest 100
                  cubic feet; the last two digits (the tens and units) are programmed as zeros (0). Once
                  programming is complete, however, the module assembly can be read to the nearest
                  cubic foot.
              2. Slowly turn the OpenWay Gas Module drive wriggler two turns in the direction
                 indicated on the index drive rate. This lets you verify the module is counting properly
                 after assembly.

                             IMPORTANT Do not turn the drive wriggler faster than one turn per second.




              3. Read the OpenWay Gas Module assembly using the FC200 and Belt Clip radio.
                 Consult the EndPoint-Link Programming Guide or other applicable instructions for
                 details on how to read an OpenWay Gas Module.
                     •   If this reading is higher than the one you programmed in step 1 above, the ERT
                         module assembly is counting correctly.
              •   If the OpenWay Gas Module assembly reading is not higher than what was
                  programmed in step 1, replace the module with a new one.


             Attach the OpenWay Gas Module to the Meter
             After the OpenWay Gas Module has been programmed and is reading correctly, follow the
             steps below to attach the module to the meter.




2.4GZ OpenWay Gas Module Installation Guide                                                                31


Chapter 3 Sensus Meter Installation




              To Attach the OpenWay Gas Module to the Meter
                1. Gently place the OpenWay Gas Module assembly against the front of the meter as
                   shown. Make sure all four mounting screw holes in the 2.4GZ line up with the
                   corresponding holes on the meter.




                2. Insert the top-right cover mounting screw and tighten the screw just enough to hold
                   the 2.4GZ OpenWay Gas Module in place. Use the 10 - 24 x 5/8-inch screws for this
                   and the following step (you can use the original mounting screws if they were the
                   correct size and not corroded; otherwise, use the correct size as described in
                   Replacement Screws on page 25).




                3. Install the remaining three mounting screws and tighten them in the order shown
                   below.


                              IMPORTANT Meter manufacturers should torque the mounting screws 15 to 20
                              inch-pounds.




32                                                            2.4GZ OpenWay Gas Module Installation Guide