Chapter 2 American Meter Installation




28                                      Natural Gas Solutions 100G Installation Guide


CHAPTER 3

Sensus Meter Installation

               This chapter shows you how to install a 100G ERT Module on a Sensus meter.

                                  Sensus meters are also known by the following names: Invensys,
                                  Equimeter, and Rockwell. For consistency, all of these meter types will
                                  be referred to as Sensus meters for this installation procedure.




Installation Prerequisites
               The following items are required to install the Itron 100G ERT Module.


               Materials Supplied by Itron
               The following items are supplied by Itron:
                 •   100G ERT Modules
                 •   New tamper seals


               Materials Supplied By You
               You must supply the following items to install, initialize, and check the 100G ERT Module
               on the meter.
                 •   Small and medium flat-blade or Phillips screwdrivers Used to remove and tighten
                     index and index-cover screws.
                 •   Side-cutting plier/wire snips Used for cutting wire seals, if necessary.
                 •   Small putty knife Used to remove all traces of old gaskets from the meter.
                 •   Meter seals, wire seals, and seal press Used to secure the meter from tampering, if
                     necessary.
                 •   11/32-inch nut driver or other blunt tool Used to securely seat new tamper plugs
                     over screw holes.
                 •   Replacement screws Used to mount 100G ERT Module assembly to meter and
                     index to module assembly backplates.
                 •   FC200SR with EndPoint-Link or EndPoint-Link Pro software Used to program
                     and check ERT assembly.


               Replacement Screws
               Replacement screws used in this procedure are shown below.


Natural Gas Solutions 100G Installation Guide                                                               29


Chapter 3 Sensus Meter Installation



              For mounting 100G ERT Module assemblies on meters:
                •   Use 10 - 24 x5/8-inch slotted, Fillister head screws.
              For mounting indexes on 100G ERT Module backplates:
                •   Use 6 - 32 x 5/8-inch slotted, round head screws.


              Preinstallation Preparations
              Before installing the 100G ERT Module on a meter, verify that:
                •   All Itron gas modules are 100G ERT Modules for your brand of gas meters.
                •   The model numbers of all meters on which the 100G ERT Modules will be installed
                    are included in the Meter Compatibility List.


Installing the 100G ERT Module
              There are four major steps to installing the 100G ERT Module on a meter:
                •   Remove the index
                •   Assemble the 100G ERT Module
                •   Program the 100G ERT Module
                •   Attach the 100G ERT Module to the meter.
                              NOTE Properly dispose of all unused screws, old index covers, gaskets, tamper
                              seals, and other left-over materials. Do not leave any materials on customer
                              premises.




              Remove the Existing Index
              The first major step when installing a 100G ERT Module on an meter is to remove the
              index from the meter.

              To Remove the Existing Index
                1. Remove any tamper seals from the meter.




30                                                                Natural Gas Solutions 100G Installation Guide


                                                                                 Installing the 100G ERT Module



                 2. Detach the index cover from the meter by removing the four screws holding it in
                    place.



                                       4                       2




                                        1                       3




                 3. Examine the index cover screws you just removed. Verify that they are 5/8-inch long
                    and are not corroded.
                        •   If the screws are 5/8-inch long and are not corroded, keep them for later use.
                        •   If they are an incorrect length or are corroded, dispose of them properly. Use 10
                            - 24 x 5/8-inch screws as described in Replacement Screws on page 29 instead.
                                        TIP You can use the index cover you just removed as a temporary storage
                                        location for screws.

                                      NOTE Dispose of the index cover properly when finished with the installation
                                      procedure. Do not leave it on customer premises.
                 4. Unscrew one index mounting screw completely.




                 5. Remove the other index mounting screw.
                 6. Set the index aside for the moment. Place it where it will not be damaged; get filled
                    with dirt, rain or snow; or fall to the ground or floor. The index will be used later in
                    this procedure.
                 7. Examine the index screws you just removed. Verify that they are 5/8-inch long and
                    are not corroded.



Natural Gas Solutions 100G Installation Guide                                                                  31


Chapter 3 Sensus Meter Installation



                       •   If the screws are 5/8-inch long and are not corroded, keep them for later use.
                       •   If the screws are an incorrect length or are corroded, dispose of them properly.
                           Use 6 -32 x 5/8-inch screws as described in Replacement Screws on page 29
                           instead.
                8. Use a putty knife or similar object to completely remove the old index gasket from the
                   meter (if applicable). All traces of the gasket must be removed before the ERT can be
                   installed.




              Assemble the ERT Module
              When installing a 100G ERT Module, the next major step is to create the endpoint module
              assembly by combining the endpoint backplate and cover with the meter index. Follow the
              procedure below to do so.

              To Assemble the ERT
                1. Obtain a new 100G ERT module.
                2. Separate the ERT module backplate from the cover.




32                                                                Natural Gas Solutions 100G Installation Guide


                                                                              Installing the 100G ERT Module



                 3. Place the index drive gear (1) in the backplate wriggler gear cup (2) of the ERT
                    (please note that the following example uses an 11-tooth drive gear; your index may
                    have a 16- or 18-tooth drive gear, and you must use the appropriate 100G ERT
                    module for your specific meter. See the Meter Compatibility list on page 6 for more
                    information).




                     Once properly in place, the index drive gear and backplate wriggler cup should look
                     similar to the following example.




Natural Gas Solutions 100G Installation Guide                                                              33


Chapter 3 Sensus Meter Installation



                4. Attach the right-hand mounting screw to the index and meter, just far enough to hold
                   the index in place. Use one 6 - 32 x 5/8-inch screw for this step (you can use an
                   original mounting screw if it was the correct size and not corroded; otherwise, use the
                   correct size Replacement Screw see "Replacement Screws" on page 29).

                                 1                2




                5. Install and tighten the left-hand index mounting screw.




                6. Tighten the right-hand index mounting screw completely.
                7. Slide the ERT cover over the index and backplate.




34                                                               Natural Gas Solutions 100G Installation Guide


                                                                               Installing the 100G ERT Module



                 8. Verify that the cover is installed correctly.




                     Once combined, the ERT backplate, meter index, and ERT cover create an "ERT
                     Module Assembly."
                     Next, program the ERT module.


               Program the ERT
               The ERT must be programmed using the FC200SR with EndPoint-Link software. See the
               Endpoint-Link ERT Programming Guide (TDC-0411) for more information.

                           IMPORTANT You must perform the following programming procedure for
                           the ERT module to function properly.

               When programming the ERT module, you must take note of the drive rate shown on the
               index of the meter. Program the meter based on the drive rate shown on the index. Sensus
               meters. Sensus meters have a 2-foot drive rate, as indicated in the example below (1), or a
               0.05 cubic metre drive (not shown).




                                                          1


               To Program the ERT Module
                 1. Using the FC200SR, program the reading of the index that was on the meter into the
                    ERT module assembly.


Natural Gas Solutions 100G Installation Guide                                                                35


Chapter 3 Sensus Meter Installation



                       •   For initial programming, hold the FC200SR approximately 1 foot away from
                           the 100G.
                       •   For reprogramming (30 days or more past initial programming), hold the
                           FC200SR approximately 4 to 5 feet away from the 100G.
                    Be sure to program the 100G to the correct mode for the reading technology what will
                    be used (for example, Fixed Network Mode, Mobile/Handheld Mode, or Hard to Read
                    Mobile/Handheld Mode). In Endpoint-Link Pro v5.0, you will have access to the one
                    mode that was defined by your system administrator.
                    During programming, the 100G ERT module is programmed to the nearest 100 cubic
                    feet; the last two digits (the tens and units) are programmed as zeros (0). Once
                    programming is complete, however, the ERT module assembly can be read to the
                    nearest cubic foot.
                2. Slowly turn the ERT module drive wriggler two turns in the direction indicated on the
                   index drive rate. This lets you verify the ERT module is counting properly after
                   assembly.

                                IMPORTANT Do not turn the drive wriggler faster than one turn per second.




                3. Read the ERT module assembly using the FC200SR. Consult the EndPoint-Link ERT
                   Programming Guide (TDC-0411) or other applicable instructions for details on how to
                   read an ERT.
                       •   If this reading is higher than the one you programmed in step 1 above, the ERT
                           module assembly is counting correctly.
                       •   If the ERT module assembly reading is not higher than what was programmed
                           in step 1, replace the ERT module with a new one.


              Attach the ERT to the Meter
              After the endpoint has been programmed and is reading correctly, it must be attached to the
              meter. Follow the steps below to do this.




36                                                               Natural Gas Solutions 100G Installation Guide


                                                                               Installing the 100G ERT Module




               To Attach the ERT to the Meter
                 1. Gently place the ERT module assembly against the front of the meter as shown. Make
                    sure all four mounting screw holes in the ERT module assembly line up with the
                    corresponding holes on the meter.




                 2. Insert the top-right cover mounting screw. Tighten the screw just enough to hold the
                    ERT module assembly in place. Use the 10 - 24 x 5/8-inch screws for this and the
                    following step (you can use the original mounting screws if they were the correct size
                    and not corroded; otherwise, use the correct size as described in Replacement Screws
                    on page 29).




                 3. Turn each screw 1/4 to 1/2 turn after it contacts the cover.


                               IMPORTANT Meter manufacturers should torque the mounting screws 15 to 20
                               inch-pounds.




Natural Gas Solutions 100G Installation Guide                                                             37


Chapter 3 Sensus Meter Installation




                                 3

                                 1        2




                4. Place a new tamper seal over two of the mounting screws as shown below.




                                      1

                                              2




38                                                            Natural Gas Solutions 100G Installation Guide


                                                                              Installing the 100G ERT Module



                 5. Press the new tamper seals into place using the 11/32-inch nut driver (or another
                    similar blunt tool).




                 6. Complete any necessary paperwork. Make sure no excess material is left on the
                    customer premises.
                     The ERT is now installed on the meter.




Natural Gas Solutions 100G Installation Guide                                                            39


Chapter 3 Sensus Meter Installation




40                                    Natural Gas Solutions 100G Installation Guide


CHAPTER 4

Actaris Meter Installation

               This chapter shows you how to install a 100G ERT Module on an Actaris meter.

                                  Actaris meters are also known by the names: Sprague, and
                                  Schlumberger. For consistency, all of these meter types will be referred
                                  to as Actaris meters for this installation procedure.

               Before installing the 100G ERT Module, verify that you have:
                 •   A compatible meter shown in the Meter Compatibility List.
                 •   A compatible index. Itron 100G ERT Modules can be used with standard dial and
                     direct read (odometer) indexes.
                 •   The list of materials defined under Installation Prerequisites in this chapter.


Installation Prerequisites
               The following items are required to install the Itron 100G ERT Module.


               Materials Supplied by Itron
               The following items are supplied by Itron:
                 •   100G ERT Modules
                 •   New tamper seals


               Materials Supplied By You
               You must supply the following items to install, initialize, and check the 100G ERT Module
               on the meter.
                 •   Small and medium flat-blade or Phillips screwdrivers Used to remove and tighten
                     index and index-cover screws.
                 •   Side-cutting plier/wire snips Used for cutting wire seals, if necessary.
                 •   Small putty knife Used to remove all traces of old gaskets from the meter.
                 •   Meter seals, wire seals, and seal press Used to secure the meter from tampering, if
                     necessary.
                 •   11/32-inch nut driver or other blunt tool Used to securely seat new tamper plugs
                     over screw holes.
                 •   Replacement screws Used to mount 100G ERT Module assembly to meter and
                     index to module assembly backplates.




Natural Gas Solutions 100G Installation Guide                                                                41


Chapter 4 Actaris Meter Installation



                 •   FC200SR with EndPoint-Link or EndPoint-Link Pro software Used to program
                     and check ERT assembly.


               Replacement Screws
               Replacement screws used in this procedure are shown below.

               For mounting 100G ERT Module assemblies on meters:
                 •   Use 10 - 24 x5/8-inch slotted, Fillister head screws.
               For mounting indexes on 100G ERT Module backplates:
                 •   Use 10 - 24 x 1/4-inch slotted, round head screws.


               Preinstallation Preparations
               Before installing the 100G ERT Module on a meter, verify that:
                 •   All Itron gas modules are 100G ERT Modules for your brand of gas meters.
                 •   The model numbers of all meters on which the 100G ERT Modules will be installed
                     are included in the Meter Compatibility List.


Installing the 100G ERT Module
               There are four major steps to installing the 100G ERT Module on a meter:
                 •   Remove the index
                 •   Assemble the 100G ERT Module
                 •   Program the 100G ERT Module
                 •   Attach the 100G ERT Module to the meter.
                               NOTE Properly dispose of all unused screws, old index covers, gaskets, tamper
                               seals, and other left-over materials. Do not leave any materials on customer
                               premises.




               Remove the Index
               The first major step when installing a 100G ERT Module on an meter is to remove the
               index from the meter.

               To Remove the Index
                 1. Remove tamper seals from the meter.




42                                                                 Natural Gas Solutions 100G Installation Guide


                                                                                Installing the 100G ERT Module



                 2. Remove and keep the cover screws.




                 3. Remove the index cover from the meter.
                 4. Check the screws for length and corrosion. If they are 5/8 inches long and not
                    corroded, you can use them to attach the 100G ERT Module to the meter.
                     If the screws are not the correct length, or are corroded, dispose of them properly.
                     Replace them with the screws listed in Replacement Screws on page 42.
                 5. Use the index cover just removed as a temporary storage location for screws.
                               NOTE Dispose of the index cover properly when finished with the installation
                               procedure. Do not leave it on customer premises.


                 6. Loosen the index mounting screws one-half turn.




                 7. Slide the index up off its mounting screws and remove it from the meter. Set the index
                    where it won't get damaged or dirty.




Natural Gas Solutions 100G Installation Guide                                                               43


Chapter 4 Actaris Meter Installation



                 8. Remove the index mounting screws from the meter. Check the screws for length and
                    corrosion. If they are 1/4 inches long and not corroded, you can use them to attach the
                    100G ERT Module to the meter.




                     If the screws are not the correct length, or are corroded, dispose of them properly.
                     Replace them with the screws listed in Replacement Screws on page 42.
                 9. Remove all traces of the old index gasket from the meter. The new 100G ERT Module
                    has its own gasket.




                 10. Dispose of the old gasket properly and do not leave it on the customer premises.


               Assemble the ERT Module
               When installing a 100G ERT Module, the next major step is to create the endpoint module
               assembly by combining the endpoint backplate and cover with the meter index. Follow the
               procedure below to do so.

               To Separate the Cover from the Backplate
                 1. Obtain a new 100G ERT Module.




44                                                                 Natural Gas Solutions 100G Installation Guide


                                                                               Installing the 100G ERT Module



                 2. Place your thumb in the notch on the bottom of the endpoint to hold the backplate and
                    pull the cover away from the backplate.




                      You can also separate the cover from the backplate by gently pulling on the wriggler
                      until the backplate comes free.




                 3.   Set the cover aside where it won't be damaged.
                 4. Put the index mounting screws about two turns into the backplate index mounting
                    posts.




Natural Gas Solutions 100G Installation Guide                                                                45


Chapter 4 Actaris Meter Installation



                 5. Position the backplate and index wrigglers as shown below.




                 6. Slide the index mounting brackets onto the mounting screws.




                 7. Make sure the backplate wriggler post is below the index wriggler when lowering the
                    index mounting brackets onto the index mounting screws.




46                                                              Natural Gas Solutions 100G Installation Guide


                                                                                Installing the 100G ERT Module



                 8. Hold the index in place with your thumb and tighten the index mounting screws.




                 9. Slide the cover over the index and onto the backplate until it is against the gasket.




               Program the ERT
               The ERT must be programmed using the FC200SR with EndPoint-Link software. See the
               Endpoint-Link ERT Programming Guide (TDC-0411) for more information.

                           IMPORTANT You must perform the following programming procedure for
                           the ERT module to function properly.

               When programming the ERT module, you must take note of the drive rate shown on the
               index of the meter. Program the meter based on the drive rate shown on the index.

               To program the ERT module
                 1. Using the FC200SR, program the reading of the index that was on the meter into the
                    ERT module assembly.




Natural Gas Solutions 100G Installation Guide                                                               47


Chapter 4 Actaris Meter Installation



                        •   For initial programming, hold the FC200SR approximately 1 foot away from
                            the 100G.
                        •   For reprogramming (30 days or more past initial programming), hold the
                            FC200SR approximately 4 to 5 feet away from the 100G.
                     Be sure to program the 100G to the correct mode for the reading technology what will
                     be used (for example, Fixed Network Mode, Mobile/Handheld Mode, or Hard to Read
                     Mobile/Handheld Mode). In Endpoint-Link Pro v5.0, you will have access to the one
                     mode that was defined by your system administrator.
                     During programming, the 100G ERT module is programmed to the nearest 100 cubic
                     feet; the last two digits (the tens and units) are programmed as zeros (0). Once
                     programming is complete, however, the ERT module assembly can be read to the
                     nearest cubic foot.
                 2. Slowly turn the ERT module drive wriggler two turns in the direction indicated on the
                    index drive rate. This lets you verify the ERT module is counting properly after
                    assembly.

                                 IMPORTANT Do not turn the drive wriggler faster than one turn per second.

                 3. Read the ERT module assembly using the FC200SR. Consult the EndPoint-Link ERT
                    Programming Guide (TDC-0411) or other applicable instructions for details on how to
                    read an ERT.
                        •   If this reading is higher than the one you programmed in step 1 above, the ERT
                            module assembly is counting correctly.
                        •   If the ERT module assembly reading is not higher than what was programmed
                            in step 1, replace the ERT module with a new one.


               Attach the ERT Module to the Meter
               After the endpoint has been programmed and is reading correctly, it must be attached to the
               meter. Follow the steps below to do this.




48                                                                Natural Gas Solutions 100G Installation Guide


                                                                                Installing the 100G ERT Module




               To Attach the Endpoint to the Meter
                 1. Turn the white wriggler so one of its four drive slots lines up with the drive dog.




                 2. Gently place the 100G ERT Module on the meter.
                     If there is a gap between the gasket and the meter, it is probably because the drive slot
                     of the ERT module assembly's wriggler is not properly aligned with the meter
                     wriggler drive dog. To correct this, remove the assembly and repeat the alignment
                     procedure in step one.
                 3. Turn each screw 1/4 to 1/2 turn after it contacts the cover.


                               IMPORTANT Meter manufacturers should torque the mounting screws 15 to 20
                               inch-pounds.




Natural Gas Solutions 100G Installation Guide                                                               49


Chapter 4 Actaris Meter Installation



                               Only two screws are required to mount the 100G ERT Module. Dispose
                               of the extra screw properly. Do not leave it on the customer premises.


                 4. Press new tamper seals into place with an 11/32 nut driver, or other blunt tool.




                 5.


               Attaching the ERT Module to Flat-faced Model 1A Meters
               If you want to install a 100G ERT Module on a flat-faced model 1A meter you will have to
               use the CFG-0015-001 adapter kit. Obtain the kit from Itron then use the following
               procedure to install the kit and the 100G ERT Module.
                 1. Make sure you have all of the following items in the kit.




                 2. Remove the drive dog from the meter and replace it with the one from the kit.




50                                                                Natural Gas Solutions 100G Installation Guide


                                                                                 Installing the 100G ERT Module



                              IMPORTANT Do not use a tool to install or tighten the new drive
                              dog, hand tighten only.




                 3. Attach Adapter Shim Plate to the meter, as shown, using the two index mounting
                    screws from the kit. Apply 15 to 20 inch-pounds of torque to the screws to provide a
                    tight seal between the shim plate and the meter.




                               If the gasket is not attached to the shim plate, please request Itron PRA-
                               0056-008.




Natural Gas Solutions 100G Installation Guide                                                               51


Chapter 4 Actaris Meter Installation



                 4. Turn the white wriggler so one of its four drive slots lines up with the drive dog.




                 5. Gently place the 100G ERT Module on the meter.
                     If there is a gap between the gasket and the meter, it is probably because the drive slot
                     of the ERT module assembly's wriggler is not properly aligned with the meter
                     wriggler drive dog. To correct this, remove the assembly and repeat the alignment
                     procedure in step one.
                 6. Turn each screw 1/4 to 1/2 turn after it contacts the cover.


                               IMPORTANT Meter manufacturers should torque the mounting screws 15 to 20
                               inch-pounds.




                               Only two screws are required to mount the 100G ERT Module. Dispose
                               of the extra screw properly. Do not leave it on the customer premises.




52                                                                 Natural Gas Solutions 100G Installation Guide


                                                                               Installing the 100G ERT Module



                 7. Press new tamper seals into place with an 11/32 nut driver, or other blunt tool.




Natural Gas Solutions 100G Installation Guide                                                             53


Chapter 4 Actaris Meter Installation




54                                     Natural Gas Solutions 100G Installation Guide


CHAPTER 5

American/Actaris Commercial Meter Installation

               This chapter shows you how to install a 100G ERT Module on an American Commercial
               meter.

               Before installing the 100G ERT Module, verify that you have:
                 •   A compatible meter shown in the Meter Compatibility List.
                 •   A compatible index. Itron 100G ERT Modules can be used with standard dial and
                     direct read (odometer) indexes.
                 •   The list of materials defined under Installation Prerequisites in this chapter.
                               IMPORTANT The 100G ERT Module must be handled carefully so that the
                               metal passive radiator antenna does not get damaged.

                                        Passive radiator
                                           antenna




Installation Prerequisites
               The following items are required to install the Itron 100G ERT Module.


               Materials Supplied by Itron
               The following items are supplied by Itron:
                 •   100G ERT Modules


Natural Gas Solutions 100G Installation Guide                                                          55