User Manual

FCC ID: EO9100G

Users Manual

Download: PDF
FCCID_728189

Natural Gas Solutions
 100G Installation Guide
        Revision A


Identification
100G Installation Guide -- DRAFT
Part number: PUB-0200-001 Revision A 10/06
ERT Part Numbers: ERG-aaaa-bbb, CCCC-ddd, etc.

Copyright
© 2006 Itron, Inc. All rights reserved.
Your company has the right to reproduce this contract document, provided that such reproduction shall be subject to the same use and disclosure restrictions contained in the
Confidentiality and Non-Disclosure paragraphs in the Sales Contract.

Applicable Patents
U.S. Patent Numbers: XXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXX????
Canadian Patent Numbers: XXXXXXXXXXX XXXXXXXXXX XXXXXXXXX?????????

Transportation Classification
Itron classifies and ships model 100G ERT modules as a non-hazardous material. The proper shipping name is Lithium Batteries contain in Equipment, Class 9, UN3091, Packing
Group II.
The Federal Aviation Administration prohibits operating transmitters and receivers on all commercial aircraft. When powered, the 100G ERT module is considered an operating
transmitter and receiver and cannot be shipped by air.

Compliance Statement
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance
with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation.
If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct
the interference by one or more of the following measures:
       • Reorient or relocate the receiving antenna.
       • Increase the separation between the equipment and receiver.
       • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
       • Consult the dealer or an experienced radio or TV technician for help.
This device complies with Subpart C of Part 15 of FCC Rules. Operation of this device is subject to the following two conditions:
       • This device may not cause harmful interference.
       • This device must accept any interference that may cause undesirable operation.
This device must be permanently mounted such that it retains a distance of 20 centimeters (7.9 inches) from all persons in order to comply with FCC RF exposure levels.

Modification and Repairs
To ensure FCC compliance and system performance, this device and antenna shall not be changed or modified without the expressed approval of Itron. Any unauthorized modification
will void the user’s authority to operate the equipment.

Meter Installation/Removal
In the event of malfunction, all repairs should be performed by Itron. It is the responsibility of users requiring service to report the need for service to Itron.

Related Documents
EndPoint-Link ERT Programming Guide (TDC-tbd-tbd)

Trademark Notice
ERT and Itron are both registered trademarks of Itron, Inc. All other product names and logos in this documentation are used for identification purposes only and may be trademarks or
registered trademarks of their respective companies.

Suggestions
If you have comments or suggestions on how we may improve this documentation, send them to TechnicalCommunicationsManager@itron.com.
If you have questions or comments about this application, contact Itron Technical Support:
      Itron, Inc.
      • Mail: Itron, Inc. 2401 North State Street, Waseca, MN 56093
      • E-mail: support@itron.com
      • Phone: 1 800 392 3185; Fax: 507 837 4451


Table of Contents


Chapter 1 Getting Started ...........................................................................................1
      Transmission Modes ...........................................................................................................................1
      Specifications ......................................................................................................................................1
      Meter Compatibility List .......................................................................................................................2


Chapter 2 American Meter Installation .......................................................................5
      Installation Prerequisites .....................................................................................................................5
              Materials Supplied By Itron .......................................................................................................5
              Materials Supplied By You........................................................................................................5
                    Replacement Screws......................................................................................................6
              Preinstallation Preparations ......................................................................................................6
      Installing the 100G on an American Meter..........................................................................................6
              Remove the Existing Index .......................................................................................................6
              Assemble the ERT Module .......................................................................................................9
              Program the ERT Module .......................................................................................................13
              Attach the ERT Module to the Meter ......................................................................................15


Chapter 3 Sensus Meter Installation.........................................................................19
      Introduction........................................................................................................................................19
      Installation Prerequisites ...................................................................................................................19
              Materials Supplied By Itron .....................................................................................................19
              Materials Supplied by You ......................................................................................................19
                    Replacement Screws....................................................................................................19
      Preinstallation Preparations ..............................................................................................................20
      Installing the 100G on a Sensus Meter .............................................................................................20
              Remove the Existing Index .....................................................................................................20
              Assemble the ERT Module .....................................................................................................22
              Program the ERT ....................................................................................................................24
              Attach the ERT to the Meter ...................................................................................................25




100G Installation Guide                                                                                                                                    iii


Table of Contents




iv                  100G Installation Guide


CHAPTER 1

Getting Started

              The 100G is Itron's latest high-powered gas encoder-receiver-transmitter (ERT) module.

              ERTs are meter-installed devices that transmit meter data using radio communications. That
              information may be received by a reading device that is within transmission distance,
              meaning that multiple devices may receive data from a single endpoint. Itron's 100G ERT is
              a high-powered device with a wide transmission distance.

              This installation guide shows you how to install the 100G ERT module on meters from a
              variety of manufacturers. To ensure you have a meter that is compatible with the 100G ERT
              module, please see the Meter Compatibility List on page 2.


Transmission Modes
              Once installed, the 100G ERT module has two standard available transmission modes:
                •   Fixed Network Mode In this mode, a 100G ERT module transmits a high-powered
                    RF message every 60 seconds.
                •   Mobile and HandHeld Mode In this mode, a 100G ERT module transmits a
                    medium-powered RF message every 15 seconds.
              An FCC license is not required to read 100G ERT modules.


Specifications
              The functional and operational specifications for the 100G are listed below.
              Functional Specifications               Description
              Power Source                            "A" cell lithium battery
              Tamper Detection                        Tilt tamper and magnetic tamper
              FCC Compliance                          Part 15 certified
              Industry Canada Compliance              RSS-210 certified
              Measurement Canada Approval             Yes
              Intrinsically Safe per                  Factory Mutual and UL Class I, Division 1, Groups C
                                                      and D
              Product Identification                  Numeric and barcoded ERT module type and serial
                                                      number
              Contstruction Materials                 Gray polycarbonate back plate with Santoprene®
                                                      gasket; clear polycarbonate front cover; encapsulated
                                                      electronics




100G Installation Guide                                                                                       1


Chapter 1 Getting Started


                 Operational Specifications                  Description
                 Operating Temperatures                      -40° to 158° F (-40° to +70° C)
                 Operating Humidity                          5 to 95percent relative humidity
                 Program Frequency                           908 MHz
                 Transmit Frequency                          Spread spectrum 908 to 924 MHz ISM band
                 Data Integrity                              Verified in every data message




Meter Compatibility List
                 The following meters are compatible with the 100G. Due to continuous research, product
                 improvements, and enhancements, Itron reserves the right to change this list at any time.

                 To ensure you have the latest Meter Compatibility list available, contact your Itron
                 representative.

    Mfgr.                 Model       Desc.    Class           Comments          ERT Type       ERT Part No.

    American/ Canadian    W75AL                Residential     Aluminum case
                                                               Meters Only       100G           ERG-5000-001

    American/ Canadian    AL-175               Residential     Aluminum case
                                                               meters only       100G           ERG-5000-001

    American/ Canadian    AC-175               Residential     Aluminum case
                                                               meters only       100G           ERG-5000-001

    American/ Canadian    AT-175               Residential     Aluminum case
                                                               meters only       100G           ERG-5000-001

    American/ Canadian    ALC-175              Residential     Aluminum case
                                                               meters only       100G           ERG-5000-001

    American/ Canadian    AT-210               Residential     Aluminum case
                                                               meters only       100G           ERG-5000-001

    American/ Canadian    AL-225      Canada   Residential     Aluminum case
                                      only                     meters only       100G           ERG-5000-001

    American/ Canadian    AL-250               Residential     Aluminum case
                                                               meters only       100G           ERG-5000-001

    American/ Canadian    AR-250               Residential     Aluminum case
                                                               meters only       100G           ERG-5000-001

    American/ Canadian    AC-250               Residential     Aluminum case
                                                               meters only       100G           ERG-5000-001

    American/ Canadian    AT-250               Residential     Aluminum case
                                                               meters only       100G           ERG-5000-001

    American/ Canadian    AM-250               Residential     Aluminum case
                                                               meters only       100G           ERG-5000-001

    American/ Canadian    AL-310               Residential     Aluminum case
                                                               meters only       100G           ERG-5000-001




2                                                                                               100G Installation Guide


                                                                                         Meter Compatibility List


  American/ Canadian      AL-350              Residential   Aluminum case
                                                            meters only           100G   ERG-5000-001

  American/ Canadian      AT-350              Residential   Aluminum case
                                                            meters only           100G   ERG-5000-001

  American/ Canadian      AL-425              Residential   Aluminum case
                                                            meters only           100G   ERG-5000-001

  American/ Canadian      AC-630              Residential   Aluminum case
                                                            meters only           100G   ERG-5000-001

  American/ Canadian      5B 225              Residential   Aluminum case
                                                                                  100G   ERG-5000-001

  Sensus/Invensys/        R-175    11 Tooth   Residential   Compatible with 2     100G   ERG-5000-002
  Equimeter/ Rockwell                                       foot drive index; 1
                                                            foot drive has 24
                                                            teeth
  Sensus/Invensys/        R-200    11 Tooth   Residential                         100G   ERG-5000-002
  Equimeter/ Rockwell


  Sensus/Invensys/        RT-200   11 Tooth   Residential                         100G   ERG-5000-002
  Equimeter/ Rockwell


  Sensus/Invensys/        RT-230   11 Tooth   Residential                         100G   ERG-5000-002
  Equimeter/ Rockwell


  Sensus/Invensys/        R-275    11 Tooth   Residential                         100G   ERG-5000-002
  Equimeter/ Rockwell


  Sensus/Invensys/        RT-275   11 Tooth   Residential                         100G   ERG-5000-002
  Equimeter/ Rockwell


  Sensus/Invensys/        R-315    11 Tooth   Residential                         100G   ERG-5000-002
  Equimeter/ Rockwell


  Sensus/Invensys/        250      11 Tooth   Residential                         100G   ERG-5000-002
  Equimeter/ Rockwell


  Sensus/Invensys/        310      11 Tooth   Residential
                                                                                  100G   ERG-5000-002
  Equimeter/ Rockwell

  Sensus/Invensys/        S-110    11 Tooth   Residential
                                                                                  100G   ERG-5000-002
  Equimeter/ Rockwell

  Sensus/Invensys/        S-200    11 Tooth   Residential
                                                                                  100G   ERG-5000-002
  Equimeter/ Rockwell

  Sensus/Invensys/        175-S    11 Tooth   Residential
                                                                                  100G   ERG-5000-002
  Equimeter/ Rockwell

                          RT-100   18 Tooth   Residential
  Sensus/Invensys/
                                                                                  100G   ERG-5000-004
  Equimeter/ Rockwell

  Sensus/Invensys/        S-190    11 Tooth   Residential
                                                                                  100G   ERG-5000-002
  Equimeter/ Rockwell




100G Installation Guide                                                                                        3


Chapter 1 Getting Started


    Sensus/                S-120     11 Tooth   Residential
    Invensys/ Equimeter/                                      100G   ERG-5000-002
    Rockwell

    Sensus/Invensys/       T-120     11 Tooth   Residential
                                                              100G   ERG-5000-002
    Equimeter/ Rockwell

    Sensus/Invensys/       T-110     11 Tooth   Residential
                                                              100G   ERG-5000-002
    Equimeter/ Rockwell

    Sensus/Invensys/       R-415     18 Tooth   Residential
                                                              100G   ERG-5000-004
    Equimeter/ Rockwell

    Sensus/Invensys/       RT-360    18 Tooth   Residential
                                                              100G   ERG-5000-004
    Equimeter/ Rockwell

                           MR8       16 Tooth   Residential
    Sensus/Invensys/
                           (R-275                             100G   ERG-5000-003
    Equimeter/ Rockwell
                           Metric)
                           MR12      16 Tooth   Residential
    Sensus/Invensys/
                           (R-415                             100G   ERG-5000-003
    Equimeter/ Rockwell
                           Metric)




4                                                                    100G Installation Guide


CHAPTER 2

American Meter Installation

              This chapter shows you how to install a 100G gas ERT module on an American meter.

              Before installing the 100G ERT module, verify that you have:
                •   A compatible meter. See the the Meter Compatibility List on page 2 for more
                    information.
                •   A compatible index. Itron 100G gas ERT modules can be used with standard dial and
                    direct read (odometer) indexes on American Meters.
                •   The list of materials defined under Installation Prerequisites on page 5.




Installation Prerequisites
              The following items are required to install Itron's 100G gas ERT.


              Materials Supplied By Itron
              The following items are supplied by Itron.
                •   100G gas ERT modules
                •   Tamper plugs


              Materials Supplied By You
              You must supply the following items to successfully install the 100G gas ERT on the
              American Meters listed in the Meter Compatibility above.
                •   Small and medium flat-blade screwdrivers Used to remove and tighten index and
                    index-cover screws.
                •   Side-cutting plier/wire snips Used for cutting wire seals, if necessary.
                •   Small putty knife Used to remove all traces of old gaskets from the meter.
                •   Meter seals, wire seals, and seal press Used to secure the meter from tampering, if
                    necessary.
                •   11/32-inch nut driver or other blunt tool Used to securely seat new tamper plugs
                    over screw holes.
                •   FC200SR unit with EndPoint-Link or EndPoint-Link Pro software Used to
                    program and check ERT assembly.
                •   Replacement screws Used to mount ERT assembly to meter and index to ERT
                    assembly backlates; see Replacement Screws on page 6 for more information).


100G Installation Guide                                                                                   5


Chapter 2 American Meter Installation




              Replacement Screws
              Replacement screws used in this procedure must be slotted, zinc-plated, steel machine
              screws. Sizing options are shown below.
                •   Use 1/4 - 20 x 5/8-inch slotted, Fillister head screws for mounting 100G ERT module
                    assemblies on meters.
                •   Use 8 - 32 x 3/16-inch slotted, round head screws for mounting indexes on 100G ERT
                    module backplates.


              Preinstallation Preparations
              Before installing the 100G gas ERT module on a meter, verify that:
                •   All ERTs are type 100G modules for American Meter Company gas meters.
                •   The model numbers of all meters on which the 100G modules will be installed are
                    included in the Meter Compatibility see "Meter Compatibility List" on page 2 list.


Installing the 100G on an American Meter
              There are four major steps to installing the 100G gas ERT on an American Meter:
                •   Remove the Existing Index
                •   Assemble the ERT Module
                •   Program the ERT Module
                •   Attach the ERT Module to the Meter
              These procedures are described in the following sections.

                         NOTE Be sure to properly dispose of all unused screws, old index covers,
                         gaskets, and other left-over materials. Do not leave any materials on customer
                         premises.



              Remove the Existing Index
              The first major step when installing a 100G gas ERT on an American meter is to remove the
              existing index from the meter.

              To Remove the Existing Index
                1. Remove any tamper seals from the meter.




6                                                                                     100G Installation Guide


                                                                         Installing the 100G on an American Meter



                2. Detach the index cover from the meter by removing the four screws holding it in
                   place.




                3. Examine the index cover screws you just removed. Verify that they are 5/8-inch long
                   and are not corroded.
                          •   If the screws are 5/8-inch long, and are not corroded, keep them for later use.
                          •   If the screws are an incorrect length or are corroded, dispose of them properly.
                              Use 1/4 - 20 x 5/8-inch screws as described in Replacement Screws on page 6
                              instead.
                                         TIP You can use the index cover you just removed as a temporary storage
                                         location for screws.
                4. Unscrew one index mounting screw completely.
                    Hold one hand beneath the index to catch the screw when it falls out of the index
                    assembly. If it does not fall out by itself, be sure to remove it.




                5. Unscrew the other index mounting screw.




100G Installation Guide                                                                                          7


Chapter 2 American Meter Installation



                    While removing this screw, pull the index away from the meter to keep its backplate
                    (1) against the back of the screwhead (2). This prevents the screw from falling out
                    prematurely.

                                                                      1

                                                                      2




                6. Remove the screw from the index once it is completely free of its hole.
                7. Set the index aside for the moment. Place it where it will not be damaged; get filled
                   with dirt, rain, or snow; or fall to the ground or floor. The index will be used later in
                   this procedure.
                8. Examine the index screws you just removed. Verify that they are 3/16-inch long and
                   are not corroded.
                       •   If the screws are 3/16-inch long and are not corroded, keep them for later use.
                       •   If the screws are an incorrect length or are corroded, dispose of them properly.
                           Use 8 - 32 x 3/16-inch screws as described in Replacement Screws on page 6
                           instead.
                9. Use a putty knife or similar object to completely remove the old index gasket from the
                   meter (if applicable). All traces of the gasket must be removed before athe ERT can be
                   installed.




8                                                                                       100G Installation Guide


                                                                        Installing the 100G on an American Meter




              Assemble the ERT Module
              When installing a 100G gas ERT, the next major step is to create the ERT module assembly
              by combining the ERT backplate and cover with the meter index. Follow the procedure
              below to do so.

              To Assemble the ERT Module
                1. Obtain a new 100G ERT and index cover.
                2. Separate the ERT module backplate from the cover.




                3. Set the new ERT index cover aside for the moment. Place it where it will not be
                   damaged; get filled with dirt, rain, or snow; or fall to the ground or floor. The ERT
                   index cover will be used later in this procedure.
                                  IMPORTANT Before continuing with the installation, note the following
                                  information about American Meter idexes:

                          •   Index wrigglers on one-foot meters have drive slots.




100G Installation Guide                                                                                       9


Chapter 2 American Meter Installation



                       •   Index wrigglers on two-foot meters have drive posts.




                       •   An index may have mounting screw holes.




                       •   An index may have mounting screw slots.




                    If the index has mounting screw slots, skip steps 4 and 5 below. Continue with step 6.
                    If the index has mounting screw holes, perform steps 4 and 5 below, and then skip
                    steps 6 and 7.




10                                                                                   100G Installation Guide


                                                                    Installing the 100G on an American Meter



                4. If the index has mounting screw holes, place an index mounting screw (1) in the right-
                   hand mounting screw hole (2). Use one 8 - 32 3/16-inch screw for this step (you can
                   use an original mounting screw if it was the correct size and not corroded; otherwise,
                   use the correct size replacement screw).
                                                           1




                                                           2

                5. Attach the screw to the ERT backplate's right-hand index mounting post just far
                   enough to hold the screw and end of the index in place.




                6. If the index has mounting screw slots, screw an index mounting screw (1) one to two
                   turns into the ERT backplate's right-hand index mounting post (2). Use one 8 - 32
                   3/16-inch screw for this step (you can use an original mounting screw if it was the
                   correct size and not corroded; otherwise, use the correct size replacement screw).

                                  1




                                  2




100G Installation Guide                                                                                  11


Chapter 2 American Meter Installation



                7. Place the index mounting screw slot under the screw head. Do not tighten the screw
                   yet.




                8. Attach the wriggler to the index and backplate.
                       •   If the index wriggler has a drive slot (1), place the backplate wriggler's drive
                           post (2) in the index wriggler's drive slot.


                                                                                  1




                                                                                  2

                       •   If the index wriggler has a drive post (1), place the index wriggler's drive post
                           in the backplate wriggler's drive slot (2).


                                                                                      1




                                                                                      2




12                                                                                        100G Installation Guide


                                                                     Installing the 100G on an American Meter



                9. Install and tighten the left-hand index mounting screw (for indexes with either
                   mounting screw slots or holes). Use one 8 - 32 3/16-inch screw for this step (you can
                   use an original mounting screw if it was the correct size and not corroded; otherwise,
                   use the correct size replacement screw).




                10. Tighten the right-hand index mounting screw.
                11. Slide the ERT cover (1) over the index and backplate, making sure the ERT label (2)
                    is visible through the window.
                             1                            2




                    Next, program the ERT module.




              Program the ERT Module
              Once the ERT module has been assembled, the ERT must be programmed using the
              FC200/SR with EndPoint-Link software. See the EndPoint-Link ERT Programming Guide
              (TDC-tbd-xxx) for more information.

                          IMPORTANT You must perform the following programming procedure for
                          the ERT module to function properly.




100G Installation Guide                                                                                   13


Chapter 2 American Meter Installation



              When programming the ERT module, you must take note of the drive rate shown on the
              index of American meters. Examples of 1-foot (1) and 2-foot (2) drive rates are shown
              below. Be sure to program the ERT based on the indicated drive rate.




                                              1




                                             2




              To Program the ERT Module
                1. Using the FC200/SR, program the reading of the index that was on the meter into the
                   ERT module assembly. Be sure to hold the FC200/SR unit by the battery pack and
                   within a few inches of the ERT during programming and reading; this will ensure
                   proper communication between unit and the ERT.
                    During programming, the 100G ERT module is programmed to the nearest 100 cubic
                    feet; the last two digits (the tens and units) are programmed as zeros (0). Once
                    programming is complete, however, the ERT module assembly can be read to the
                    nearest cubic foot.
                2. Slowly turn the ERT module drive wriggler two turns in the direction indicated on the
                   index drive rate. This lets you verify the ERT module is counting properly after
                   assembly.



14                                                                                  100G Installation Guide


                                                                           Installing the 100G on an American Meter



                                      IMPORTANT Do not turn the drive wriggler faster than one turn per second.


                              1                             2




                3. Read the ERT module assembly using the FC200SR. Consult the EndPoint-Link ERT
                   Programming Guide (TDC-tbd-tbd) or other applicable instructions for details on how
                   to read an ERT.
                          •       If this reading is higher than the one you programmed in step 1 above, the ERT
                                  module assembly is counting correctly.
                          •       If the ERT module assembly reading is not higher than what was programmed
                                  in step 1, replace the ERT module with a new one.




              Attach the ERT Module to the Meter
              After the ERT has been programmed and is reading correctly, it must be attached to the
              meter. Follow the steps below to do this.

              To Attach the ERT to the Meter
                1. 5B 225 Meters Only If you are installing the ERT on a 5B 225 aluminum meter, cut
                   1/16-inch off each post of the ERT wriggler to prevent it from rubbing on the face of
                   the nut that holds the wriggler in place. If you are not installing on a 5B 225 meter,
                   continue to step 2 below.

                              1                             2




100G Installation Guide                                                                                         15


Chapter 2 American Meter Installation



                2. Set the wriggler to the desired position for mounting the ERT module assembly to the
                   meter.
                       •   For One-Foot Meters: Align the ERT module assembly wriggler with the meter
                           drive post (as shown below). Make sure the ERT wriggler is perpendicular to
                           the meter drive post.




                       •   For Two-Foot Meters: Align the ERT module assembly wriggler with the
                           meter slot (as shown below). Make sure the ERT wriggler is perpendicular to
                           the meter slot.




                3. Gently place the ERT module assembly on the meter. Align the four screw holes on
                   the ERT module assembly with the holes on the meter.


                           1                          2




16                                                                                  100G Installation Guide


                                                                    Installing the 100G on an American Meter



                4. Install and tighten all ERT module assembly mounting screws, working in a diagonal
                   pattern as shown below. Tighten the mounting screws to 15 to 20 inch-pounds of
                   torque. Use the 1/4 - 20 x 5/8-inch screws for this step (you can use the original
                   mounting screws if they were the correct size and not corroded; otherwise, use the
                   correct size Replacement Screws on page 6).




                                   3                  2

                                   1                  4




                5. Place a new tamper seal over two of the mounting screws as shown below.




                              2

                                                  1




                6. Press the new tamper seals into place using the 11/32-inch nut driver (or another
                   similar blunt tool).




                          2

                                              1




100G Installation Guide                                                                                  17


Chapter 2 American Meter Installation



                7. Complete any necessary paperwork. Make sure no excess material is left on the
                   customer premises; dispose of it properly.
                    The ERT is now installed on the meter.




18                                                                                100G Installation Guide


CHAPTER 3

Sensus Meter Installation


Introduction
              This chapter shows you how to install a 100G gas ERT on a compatible Sensus meter.

                                Sensus meters are also known by the following names: Invensys,
                                Equimeter, and Rockwell. For consistency, all of these meter types will
                                be referred to as Sensus meters for this installation procedure.



Installation Prerequisites

              Materials Supplied By Itron
              The following items are supplied by Itron.
                •   100G gas ERT modules
                •   Tamper plugs


              Materials Supplied by You
              You must supply the following items to successfully install the 100G gas ERT on the
              Sensus meters listed in the Meter Compatibility List on page 2.
                •   Small and medium flat-blade screwdrivers (used for index and index-cover screws)
                •   Side-cutting plier (used for cutting wire seals, if necessary)
                •   Small putty knife (to remove old gaskets)
                •   Meter seals, wire seals, and seal press (if necessary)
                •   11/32-inch nut driver or other blunt tool (to securely seat new tamper plugs)
                •   ReadOne Pro unit (used to program and check ERT assembly)
              Replacement screws (used to mount ERT assembly to meter and index to ERT assembly
              backlates; see Replacement Screws on page 19 for more information).


              Replacement Screws
              Replacement screws used in this procedure must be slotted, zinc-plated, steel machine
              screws. Sizing options are shown below.

              For mounting 100G ERT module assemblies on meters:
                •   10 - 24 x5/8-inch slotted, Fillister head


100G Installation Guide                                                                                   19


Chapter 3 Sensus Meter Installation



              For mounting indexes on 100G ERT module backplates:
                •   6 - 32 x 5/8-inch slotted, round head


Preinstallation Preparations
               Before installing the 100G gas ERT module on a meter, verify that:
                •   All ERTs are type 100G modules for Sensus gas meters.
                •   The model numbers of all meters on which the 100G modules will be installed are
                    included in the Meter Compatibility List on page 2.


Installing the 100G on a Sensus Meter
              There are three major steps to installing the 100G gas ERT on a Sensus meter:
                •   Remove the Existing Index
                •   Assemble the ERT Module
                •   Program the ERT
                •   Attach the ERT to the Meter
              These procedures are described in the following sections.

                          Be sure to properly dispose of all unused screws, old index covers, gaskets, and
                         other left-over materials. Do not leave any materials on customer premises.




              Remove the Existing Index
              The first major step when installing a 100G gas ERT on a Sensus meter is to remove the
              existing index from the meter.

              To Remove the Existing Index
                1. Remove any tamper seals from the meter.




20                                                                                    100G Installation Guide


                                                                            Installing the 100G on a Sensus Meter



                2. Detach the index cover from the meter by removing the four screws holding it in
                   place.



                                        4                        2




                                         1                       3




                3. Examine the index cover screws you just removed. Verify that they are 5/8-inch long
                   and are not corroded.
                          •   If the screws are 5/8-inch long and are not corroded, keep them for later use.
                          •   If they are an incorrect length or are corroded, dispose of them properly. Use 10
                              - 24 x 5/8-inch screws as described in Replacement Screws on page 19 instead.
                                         TIP You can use the index cover you just removed as a temporary storage
                                         location for screws.
                4. Unscrew one index mounting screw completely.




                5. Remove the other index mounting screw.
                6. Set the index aside for the moment. Place it where it will not be damaged; get filled
                   with dirt, rain or snow; or fall to the ground or floor. The index will be used later in
                   this procedure.
                7. Examine the index screws you just removed. Verify that they are 5/8-inch long and
                   are not corroded.




100G Installation Guide                                                                                        21


Chapter 3 Sensus Meter Installation



                       •   If the screws are 5/8-inch long and are not corroded, keep them for later use.
                       •   If the screws are an incorrect length or are corroded, dispose of them properly.
                           Use 6 -32 x 5/8-inch screws as described in Replacement Screws on page 19
                           instead.
                8. Use a putty knife or similar object to completely remove the old index gasket from the
                   meter (if applicable). All traces of the gasket must be removed before the ERT can be
                   installed.




              Assemble the ERT Module
              When installing a 100G gas ERT, the next major step is to create the ERT module assembly
              by combining the ERT backplate and cover with the meter index. Follow the procedure
              below to do so.

              To Assemble the ERT
                1. Obtain a new 100G ERT and index cover.
                2. Separate the ERT module backplate from the cover.
                3. Place the index drive gear (1) in the backplate wriggler gear cup (2) of the ERT
                   (please note that the following example uses an 11-tooth drive gear; your index may
                   be slightly different).

                       1                                           2




22                                                                                     100G Installation Guide


                                                                        Installing the 100G on a Sensus Meter



                    Once properly installed, the index drive gear and backplate wriggler cup should look
                    similar to the following example.




                4. Attach the right-hand mounting screw to the index and meter, just far enough to hold
                   the index in place. Use one 6 - 32 x 5/8-inch screw for this step (you can use an
                   original mounting screw if it was the correct size and not corroded; otherwise, use the
                   correct size Replacement Screw see "Replacement Screws" on page 19).




                5. Install and tighten the left-hand index mounting screw.




                6. Tighten the right-hand index mounting screw completely.


100G Installation Guide                                                                                   23


Chapter 3 Sensus Meter Installation



                7. Slide the ERT cover over the index and backplate.
                8. Verify that the cover is installed correctly; the cover's clear window should be over
                   the backplate label.




                    Once combined, the ERT backplate, meter index, and ERT cover create an "ERT
                    Module Assembly."
                    Next, program the ERT module.


              Program the ERT
              Once the ERT module has been assembled, the ERT must be programmed using the
              FC200/SR with EndPoint-Link software. See the EndPoint-Link ERT Programming Guide
              (TDC-tbd-xxx) for more information.

                          IMPORTANT You must perform the following programming procedure for
                          the ERT module to function properly.

              When programming the ERT module, you must take note of the drive rate shown on the
              index of Sensus meters. Sensus meters have a 2-foot drive rate, as indicated in the example
              below (1).




                                                        1


              To Program the ERT Module
                1. Using the FC200/SR, program the reading of the index that was on the meter into the
                   ERT module assembly. Be sure to hold the FC200/SR unit by the battery pack and
                   within a few inches of the ERT during programming and reading; this will ensure
                   proper communication between unit and the ERT.


24                                                                                    100G Installation Guide


                                                                          Installing the 100G on a Sensus Meter



                    During programming, the 100G ERT module is programmed to the nearest 100 cubic
                    feet; the last two digits (the tens and units) are programmed as zeros (0). Once
                    programming is complete, however, the ERT module assembly can be read to the
                    nearest cubic foot.
                2. Slowly turn the ERT module drive wriggler two turns in the direction indicated on the
                   index drive rate. This lets you verify the ERT module is counting properly after
                   assembly.

                                  IMPORTANT Do not turn the drive wriggler faster than one turn per second.




                3. Read the ERT module assembly using the FC200SR. Consult the EndPoint-Link ERT
                   Programming Guide (TDC-tbd-tbd) or other applicable instructions for details on how
                   to read an ERT.
                          •   If this reading is higher than the one you programmed in step 1 above, the ERT
                              module assembly is counting correctly.
                          •   If the ERT module assembly reading is not higher than what was programmed
                              in step 1, replace the ERT module with a new one.


              Attach the ERT to the Meter
              After the ERT has been programmed and is reading correctly, it must be attached to the
              meter. Follow the steps below to do this.




100G Installation Guide                                                                                     25


Chapter 3 Sensus Meter Installation




              To Attach the ERT to the Meter
                1. Gently place the ERT module assembly against the front of the meter as shown. Make
                   sure all four mounting screw holes in the ERT module assembly line up with the
                   corresponding holes on the meter.




                2. Insert the top-right cover mounting screw. Tighten the screw just enough to hold the
                   ERT module assembly in place. Use the 10 - 24 5/8-inch screws for this and the
                   following step (you can use the original mounting screws if they were the correct size
                   and not corroded; otherwise, use the correct size as described in Replacement Screws
                   on page 19).




26                                                                                   100G Installation Guide


                                                                      Installing the 100G on a Sensus Meter



                3. Install and tighten the remaining three mounting screws. Tighten the mounting screws
                   to 15 to 20 inch-pounds of torque.




                                 2


                                 3            1




                4. Tighten the top-right mounting screw.
                5. Place a new tamper seal over two of the mounting screws as shown below.




                                     1


                                               2




100G Installation Guide                                                                                 27


Chapter 3 Sensus Meter Installation



                6. Press the new tamper seals into place using the 11/32-inch nut driver (or another
                   similar blunt tool).




                7. Complete any necessary paperwork. Make sure no excess material is left on the
                   customer premises.
                    The ERT is now installed on the meter.




28                                                                                   100G Installation Guide



Document Created: 2006-10-30 10:28:31
Document Modified: 2006-10-30 10:28:31