Test report

FCC ID: EMJMAW310M

Test Report

Download: PDF
FCCID_4318324

                                                               FCC Test Report

                       Report No.: RF190524D07

                             FCC ID: EMJMAW310M

                       Test Model: AW310M

                 Received Date: May 24, 2019

                         Test Date: May 28, 2019

                     Issued Date: Jun. 4, 2019


                         Applicant: PRIMAX ELECTRONICS LTD.

                          Address: No. 669, Ruey Kuang Road, Neihu, Taipei, Taiwan, R.O.C.


                        Issued By: Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch

             Lab Address: No. 47-2, 14th Ling, Chia Pau Vil., Lin Kou Dist., New Taipei City, Taiwan,
                          R.O.C.
       FCC Registration /
      Designation Number: 198487 / TW2021




This report is for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted
only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this
report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product
unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you
provided to us. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence, provided,
however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time
shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Unless specific
mention, the uncertainty of measurement has been explicitly taken into account to declare the compliance or non-compliance to the specification. The report
must not be used by the client to claim product certification, approval, or endorsement by TAF or any government agencies.




Report No.: RF190524D07                                              Page No. 1 / 24                                            Report Format Version: 6.1.1


                                                                   Table of Contents
Release Control Record .................................................................................................................................. 3
1         Certificate of Conformity...................................................................................................................... 4
2         Summary of Test Results ..................................................................................................................... 5
    2.1      Measurement Uncertainty ................................................................................................................... 5
    2.2      Modification Record ............................................................................................................................ 5
3         General Information .............................................................................................................................. 6
    3.1      General Description of EUT ................................................................................................................ 6
    3.2      Description of Test Modes ................................................................................................................... 7
    3.2.1    Test Mode Applicability and Tested Channel Detail............................................................................. 8
    3.3      Description of Support Units ............................................................................................................... 9
    3.3.1    Configuration of System under Test .................................................................................................... 9
    3.4      General Description of Applied Standards .......................................................................................... 9
4         Test Types and Results ...................................................................................................................... 10
    4.1      Radiated Emission and Bandedge Measurement............................................................................. 10
    4.1.1    Limits of Radiated Emission and Bandedge Measurement .............................................................. 10
    4.1.2    Test Instruments ................................................................................................................................. 11
    4.1.3    Test Procedures................................................................................................................................. 12
    4.1.4    Deviation from Test Standard ............................................................................................................ 12
    4.1.5    Test Setup .......................................................................................................................................... 13
    4.1.6    EUT Operating Conditions................................................................................................................. 14
    4.1.7    Test Results ....................................................................................................................................... 15
    4.2      Channel Bandwidth ........................................................................................................................... 21
    4.2.1    Test Setup .......................................................................................................................................... 21
    4.2.2    Test Instruments ................................................................................................................................ 21
    4.2.3    Test Procedure .................................................................................................................................. 21
    4.2.4    Deviation from Test Standard ............................................................................................................ 21
    4.2.5    EUT Operating Condition .................................................................................................................. 21
    4.2.6    Test Results ....................................................................................................................................... 22
5         Pictures of Test Arrangements .......................................................................................................... 23
Appendix – Information of the Testing Laboratories ................................................................................. 24




Report No.: RF190524D07                                              Page No. 2 / 24                                             Report Format Version: 6.1.1


                                          Release Control Record


Issue No.             Description                                         Date Issued
RF190524D07           Original release.                                   Jun. 4, 2019




Report No.: RF190524D07                      Page No. 3 / 24       Report Format Version: 6.1.1


1    Certificate of Conformity


            Product: Mouse

              Brand: ALIENWARE

        Test Model: AW310M

    Sample Status: Engineering sample

          Applicant: PRIMAX ELECTRONICS LTD.

          Test Date: May 28, 2019

         Standards: 47 CFR FCC Part 15, Subpart C (Section 15.249)
                          ANSI C63.10: 2013



The above equipment has been tested by Bureau Veritas Consumer Products Services (H.K.) Ltd.,
Taoyuan Branch, and found compliance with the requirement of the above standards. The test record, data
evaluation & Equipment Under Test (EUT) configurations represented herein are true and accurate accounts
of the measurements of the sample’s RF characteristics under the conditions specified in this report.




     Prepared by :                                                     , Date:           Jun. 4, 2019
                              Jessica Cheng / Senior Specialist




     Approved by :                                                     , Date:           Jun. 4, 2019
                            Rex Lai / Associate Technical Manager




Report No.: RF190524D07                        Page No. 4 / 24                        Report Format Version: 6.1.1


2     Summary of Test Results


                             47 CFR FCC Part 15, Subpart C (SECTION 15.249)

       FCC
                              Test Item                     Result                  Remarks
      Clause
      15.207        AC Power Conducted Emission                N/A    Power supply is 1.5Vdc from battery
      15.215      Channel Bandwidth Measurement         -
                Radiated Emission Test
                Band Edge Measurement
    15.209                                                        Meet the requirement of limit.
                Limit: 50dB less than the peak value
    15.249                                               PASS     Minimum passing margin is
                of fundamental frequency or meet
  15.249 (d)                                                      -7.34dB at 2441.00MHz.
                radiated emission limit in section
                15.209
    15.203      Antenna Requirement                      PASS     No antenna connector is used.
Note: Determining compliance based on the results of the compliance measurement, not taking into account
measurement instrumentation uncertainty.



2.1    Measurement Uncertainty
Where relevant, the following measurement uncertainty levels have been estimated for tests performed on
the EUT as specified in CISPR 16-4-2:

                                                                                     Expanded Uncertainty
                   Measurement                                  Frequency
                                                                                          (k=2) (±)
                                                           9kHz ~ 30MHz                    2.38 dB
         Radiated Emissions up to 1 GHz
                                                         30MHz ~ 1000MHz                   5.54 dB
         Radiated Emissions above 1 GHz                     Above 1GHz                     5.48 dB




2.2    Modification Record
There were no modifications required for compliance.




Report No.: RF190524D07                      Page No. 5 / 24                          Report Format Version: 6.1.1


3     General Information
3.1     General Description of EUT

Product                      Mouse
Brand                        ALIENWARE
Test Model                   AW310M
Status of EUT                Engineering sample
Power Supply Rating          1.5Vdc from battery
Modulation Type              GFSK
Operating Frequency          2402MHz ~ 2479MHz
Number of Channel            78
Antenna Type                 Printed antenna with 2.13 dBi gain
Antenna Connector            N/A
Accessory Device             N/A
Data Cable Supplied          N/A
Note: The above EUT information is declared by manufacturer and for more detailed features description,
     please refer to the manufacturer's specifications or user's manual.




Report No.: RF190524D07                      Page No. 6 / 24                       Report Format Version: 6.1.1


3.2   Description of Test Modes
78 channels are provided to this EUT:

                 FREQ.                  FREQ.                   FREQ.                   FREQ.
 CHANNEL                  CHANNEL                   CHANNEL             CHANNEL
                 (MHz)                  (MHz)                   (MHz)                   (MHz)
      0           2402          20      2422               40   2442      60             2462
      1           2403          21      2423               41   2443      61             2463
      2           2404          22      2424               42   2444      62             2464
      3           2405          23      2425               43   2445      63             2465
      4           2406          24      2426               44   2446      64             2466
      5           2407          25      2427               45   2447      65             2467
      6           2408          26      2428               46   2448      66             2468
      7           2409          27      2429               47   2449      67             2469
      8           2410          28      2430               48   2450      68             2470
      9           2411          29      2431               49   2451      69             2471
      10          2412          30      2432               50   2452      70             2472
      11          2413          31      2433               51   2453      71             2473
      12          2414          32      2434               52   2454      72             2474
      13          2415          33      2435               53   2455      73             2475
      14          2416          34      2436               54   2456      74             2476
      15          2417          35      2437               55   2457      75             2477
      16          2418          36      2438               56   2458      76             2478
      17          2419          37      2439               57   2459      77             2479
      18          2420          38      2440               58   2460
      19          2421          39      2441               59   2461




Report No.: RF190524D07                  Page No. 7 / 24                 Report Format Version: 6.1.1


3.2.1       Test Mode Applicability and Tested Channel Detail

EUT Configure                         Applicable To
                                                                                              Description
    Mode
                       RE1G       RE<1G           PLC            APCM

        -                √           √            Note 1             √      -
             RE1G: Radiated Emission above 1GHz &
Where                                                        RE<1G: Radiated Emission below 1GHz
             Bandedge Measurement
             PLC: Power Line Conducted Emission              APCM: Antenna Port Conducted Measurement
NOTE 1 : No need to concern of Conducted Emission due to the EUT is powered by battery

 Radiated Emission Test (Above 1GHz):
    Pre-Scan has been conducted to determine the worst-case mode from all possible combinations
    between available modulations, data rates and antenna ports (if EUT with antenna diversity
    architecture).
    Following channel(s) was (were) selected for the final test as listed below.
        EUT Configure Mode               Available Channel                Tested Channel                Modulation Type

                   -                          0 to 77                           0, 39, 77                    GFSK


 Radiated Emission Test (Below 1GHz):
    Pre-Scan has been conducted to determine the worst-case mode from all possible combinations
    between available modulations, data rates and antenna ports (if EUT with antenna diversity
    architecture).
    Following channel(s) was (were) selected for the final test as listed below.
        EUT Configure Mode               Available Channel                Tested Channel                Modulation Type

                   -                          0 to 77                              39                        GFSK


 Antenna Port Conducted Measurement:
    This item includes all test value of each mode, but only includes spectrum plot of worst value of each
    mode.
    Pre-Scan has been conducted to determine the worst-case mode from all possible combinations
    between available modulations, data rates and antenna ports (if EUT with antenna diversity
    architecture).
    Following channel(s) was (were) selected for the final test as listed below.
        EUT Configure Mode               Available Channel                Tested Channel                Modulation Type

                   -                          0 to 77                           0, 39, 77                    GFSK


 Test Condition:
             Applicable To          Environmental Conditions                Input Power                     Tested By
                RE1G                    23deg. C, 70%RH                         1.5Vdc                     Ian Chang
                RE<1G                    23deg. C, 70%RH                         1.5Vdc                     Ian Chang
                APCM                     25deg. C, 76%RH                         1.5Vdc                     Saxon Lee




Report No.: RF190524D07                                 Page No. 8 / 24                            Report Format Version: 6.1.1


3.3     Description of Support Units
The EUT has been tested as an independent unit together without any necessary accessory or support unit.

3.3.1    Configuration of System under Test




                                                       EUT




                                            (Powered from battery)




3.4     General Description of Applied Standards


 The EUT is a RF Product. According to the specifications of the manufacturer, it must comply with the
 requirements of the following standards:

 FCC Part 15, Subpart C (15.249)
 ANSI C63.10-2013

 All test items have been performed and recorded as per the above standards.




Report No.: RF190524D07                      Page No. 9 / 24                         Report Format Version: 6.1.1


4       Test Types and Results
4.1     Radiated Emission and Bandedge Measurement
4.1.1    Limits of Radiated Emission and Bandedge Measurement

The field strength of emissions from intentional radiators operated within these frequency bands shall comply
with the following

           Fundamental             Field Strength of Fundamental          Field Strength of Harmonics
            Frequency                     (millivolts/meter)                   (microvolts/meter)

          902 ~ 928 MHz                          50                                    500
        2400 ~ 2483.5 MHz                        50                                    500
         5725 ~ 5875 MHz                         50                                    500
         24 ~ 24.25 GHz                          250                                  2500


Emissions radiated outside of the specified frequency bands, except for harmonics, shall be attenuated by
at least 50 dB below the level of the fundamental or to the general radiated emission limits as below table,
whichever is the lesser attenuation

            Frequencies                         Field Strength                  Measurement Distance
               (MHz)                          (microvolts/meter)                      (meters)

            0.009 ~ 0.490                        2400/F(kHz)                              300

            0.490 ~ 1.705                       24000/F(kHz)                                 30
            1.705 ~ 30.0                               30                                    30
               30 ~ 88                                 100                                   3
              88 ~ 216                                 150                                   3
              216 ~ 960                                200                                   3
             Above 960                                 500                                   3
NOTE:
1.  The lower limit shall apply at the transition frequencies.
2.  Emission level (dBuV/m) = 20 log Emission level (uV/m).
3.  For frequencies above 1000MHz, the field strength limits are based on average detector, however, the
    peak field strength of any emission shall not exceed the maximum permitted average limits, specified
    above by more than 20dB under any condition of modulation.




Report No.: RF190524D07                        Page No. 10 / 24                        Report Format Version: 6.1.1


4.1.2   Test Instruments

    DESCRIPTION &                                                         CALIBRATED          CALIBRATED
                                 MODEL NO.               SERIAL NO.
    MANUFACTURER                                                             DATE                UNTIL
HP Preamplifier                  8447D                   2432A03504       Feb. 20, 2019       Feb. 19, 2020
HP Preamplifier                  8449B                   3008A01201       Feb. 21, 2019       Feb. 20, 2020
MITEQ Preamplifier         AMF-6F-260400-33-8P             892164         Feb. 20, 2019       Feb. 19, 2020
Agilent
                                   N9038A               MY51210129        Mar. 05, 2019       Mar. 04, 2020
TEST RECEIVER
Schwarzbeck Antenna              VULB 9168                       139      Nov. 26, 2018       Nov. 25, 2019
Schwarzbeck Horn
                                 BBHA-9170                       212      Nov. 25, 2018       Nov. 24, 2019
Antenna
Schwarzbeck Horn
                               BBHA 9120-D1                  D130         Nov. 25, 2018       Nov. 24, 2019
Antenna
ADT. Turn Table                     TT100                    0306               NA                   NA
ADT. Tower                          AT100                    0306               NA                   NA
Software                    Radiated_V7.6.15.9.5                 NA             NA                  NA
SUHNER RF cable
                                    SF102               Cable-CH6-01      Aug. 13, 2018       Aug. 12, 2019
With 4dB PAD
SUHNER RF cable
                                    SF102             Cable-CH8-3.6m      Aug. 13, 2018       Aug. 12, 2019
With 3/4dB PAD
KEYSIGHT MIMO
Powermeasurement Test             U2021XA               U2021XA-001        Jun. 4, 2018        Jun. 3, 2019
set
KEYSIGHT
                                   N9030A               MY54490260         Aug. 3, 2018        Aug. 2, 2019
Spectrum Analyzer
Loop Antenna EMCI                  LPA600                        270      Aug. 11, 2017       Aug. 10, 2019
EMCO Horn Antenna                    3115                 00028257        Nov. 25, 2018       Nov. 24, 2019

Highpass filter
                             WHK 3.1/18G-10SS                SN 8               NA                   NA
Wainwright Instruments

ROHDE & SCHWARZ
                                    FSV40                   101042        Sep. 27, 2018       Sep. 26, 2019
Spectrum Analyzer

NOTE: 1. The calibration interval of the above test instruments is 12/24 months. And the calibrations
         are traceable to NML/ROC and NIST/USA.
      2. The horn antenna and HP preamplifier (model: 8449B) are used only for the measurement
         of emission frequency above 1GHz if tested.
      3. The test was performed in Chamber No. 6.




Report No.: RF190524D07                       Page No. 11 / 24                        Report Format Version: 6.1.1


4.1.3      Test Procedures

For Radiated emission below 30MHz
 a. The EUT was placed on the top of a rotating table 0.8 meters above the ground at a 3 meter chamber
    room. The table was rotated 360 degrees to determine the position of the highest radiation.
     b. The EUT was set 3 meters away from the interference-receiving antenna, which was mounted on the top
        of a variable-height antenna tower.
     c. Parallel, perpendicular, and ground-parallel orientations of the antenna are set to make the
        measurement.
     d. For each suspected emission, the EUT was arranged to its worst case and the rotatable table was turned
        from 0 degrees to 360 degrees to find the maximum reading.
     e. The test-receiver system was set to Quasi-Peak Detect Function and Specified Bandwidth with
        Maximum Hold Mode.
NOTE:
 1. The resolution bandwidth and video bandwidth of test receiver/spectrum analyzer is 9kHz at frequency
    below 30MHz.

For Radiated emission above 30MHz
a. The EUT was placed on the top of a rotating table 0.8 meters (for 30MHz ~ 1GHz) / 1.5 meters (for above
    1GHz) above the ground at 3 meter chamber room for test. The table was rotated 360 degrees to
    determine the position of the highest radiation.
b.      The EUT was set 3 meters away from the interference-receiving antenna, which was mounted on the top
        of a variable-height antenna tower.
c.      The height of antenna is varied from one meter to four meters above the ground to determine the
        maximum value of the field strength. Both horizontal and vertical polarizations of the antenna are set to
        make the measurement.
d.      For each suspected emission, the EUT was arranged to its worst case and then the antenna was tuned
        to heights from 1 meter to 4 meters and the rotatable table was turned from 0 degrees to 360 degrees to
        find the maximum reading.
e.      The test-receiver system was set to quasi-peak detect function and specified bandwidth with maximum
        hold mode when the test frequency is below 1 GHz.
f.      The test-receiver system was set to peak and average detect function and specified bandwidth with
        maximum hold mode when the test frequency is above 1 GHz. If the peak reading value also meets
        average limit, measurement with the average detector is unnecessary.

Note:
1. The resolution bandwidth and video bandwidth of test receiver/spectrum analyzer is 120kHz for
    Quasi-peak detection (QP) at frequency below 1GHz.
2.      The resolution bandwidth of test receiver/spectrum analyzer is 1 MHz and the video bandwidth is 3 MHz
        for Peak detection (PK) at frequency above 1GHz.
3.      The resolution bandwidth of test receiver/spectrum analyzer is 1MHz and the video bandwidth is ≥ 1/T
        (Duty cycle < 98%) or 10Hz (Duty cycle ≥ 98%) for Average detection (AV) at frequency above 1GHz.
4.      All modes of operation were investigated and the worst-case emissions are reported.


4.1.4      Deviation from Test Standard

     No deviation.



Report No.: RF190524D07                           Page No. 12 / 24                        Report Format Version: 6.1.1


4.1.5   Test Setup

 For Radiated emission below 30MHz


                                                                    1m
            EUT&                       3m
            Support Units

                              Turn Table

              80cm


                                     Ground Plane
                                     Test Receiver




 For Radiated emission 30MHz to 1GHz

                                                       Ant. Tower
                                                                     1-4m
                                                                     Variable
              EUT&
                                           3m
                                            10m
              Support Units

                                  Turn Table

                  80cm


                                       Ground Plane

                                       Test Receiver




Report No.: RF190524D07                 Page No. 13 / 24                 Report Format Version: 6.1.1


 For Radiated emission above 1GHz



                                                 Ant. Tower             1-4m
                                                                        Variable
 EUT&                               3m
 Support Units

                          Turn Table
                                         Absorber

    150cm


                                 Ground Plane
                                 Test Receiver




 For the actual test configuration, please refer to the attached file (Test Setup Photo).




4.1.6   EUT Operating Conditions

   Set the EUT under transmission condition continuously at specific channel frequency.




Report No.: RF190524D07                         Page No. 14 / 24                            Report Format Version: 6.1.1


4.1.7    Test Results
ABOVE 1GHz DATA
CHANNEL                    TX Channel 0             DETECTOR                 Peak (PK)
FREQUENCY RANGE            1GHz ~ 25GHz             FUNCTION                 Average (AV)


                   ANTENNA POLARITY & TEST DISTANCE: HORIZONTAL AT 3 M
                   EMISSION                            ANTENNA     TABLE        RAW       CORRECTION
        FREQ.                     LIMIT    MARGIN
NO.                 LEVEL                               HEIGHT     ANGLE       VALUE        FACTOR
        (MHz)                   (dBuV/m)    (dB)
                   (dBuV/m)                               (m)     (Degree)     (dBuV)        (dB/m)
 1       2390.00    55.26 PK      74.00    -18.74        1.44 H     356         55.48         -0.22
 2       2390.00     40.50 AV     54.00    -13.50        1.44 H     356         40.72         -0.22
 3       2400.00    49.59 PK      74.00    -24.41        1.44 H     356         49.81         -0.22
 4       2400.00     34.89 AV     54.00    -19.11        1.44 H     356          35.11        -0.22
 5      *2402.00    100.89 PK    114.00    -13.11        1.44 H     356         101.11        -0.22
 6      *2402.00     86.19 AV     94.00     -7.81        1.44 H     356         86.41         -0.22
 7       4804.00    56.64 PK      74.00    -17.36        2.11 H     72          50.17         6.47
 8       4804.00     41.94 AV     54.00    -12.06        2.11 H     72          35.47         6.47
 9       7206.00    58.19 PK      74.00    -15.81        2.78 H     89          45.28         12.91
 10      7206.00     43.49 AV     54.00    -10.51        2.78 H     89          30.58         12.91
                    ANTENNA POLARITY & TEST DISTANCE: VERTICAL AT 3 M
                   EMISSION                            ANTENNA     TABLE        RAW       CORRECTION
        FREQ.                     LIMIT    MARGIN
NO.                 LEVEL                               HEIGHT     ANGLE       VALUE        FACTOR
        (MHz)                   (dBuV/m)    (dB)
                   (dBuV/m)                               (m)     (Degree)     (dBuV)        (dB/m)
 1       2390.00    54.63 PK      74.00    -19.37        1.00 V     327         54.85         -0.22
 2       2390.00    40.00 AV      54.00    -14.00        1.00 V     327         40.22         -0.22
 3       2400.00    41.41 PK      74.00    -32.59        1.00 V     327         41.63         -0.22
 4       2400.00    26.71 AV      54.00    -27.29        1.00 V     327         26.93         -0.22
 5      *2402.00    92.71 PK     114.00    -21.29        1.00 V     327         92.93         -0.22
 6      *2402.00    78.01 AV      94.00    -15.99        1.00 V     327         78.23         -0.22
 7       4804.00    53.30 PK      74.00    -20.70        1.29 V     276         46.83         6.47
 8       4804.00    38.60 AV      54.00    -15.40        1.29 V     276         32.13         6.47
 9       7206.00    60.21 PK      74.00    -13.79        3.78 V     102         47.30         12.91
 10      7206.00    45.51 AV      54.00     -8.49        3.78 V     102         32.60         12.91
REMARKS:
   1. Emission Level(dBuV/m) = Raw Value(dBuV) + Correction Factor(dB/m)
   2. Correction Factor(dB/m) = Antenna Factor(dB/m) + Cable Factor(dB) – Pre-Amplifier Factor(dB)
   3. Margin value = Emission Level – Limit value
   4. The other emission levels were very low against the limit.
   5. " * ": Fundamental frequency.
   6. The average value of fundamental and harmonic frequency is: Average = Peak value + 20 log(Duty
      cycle) Where the duty factor is calculated from following formula:
      20 log(Duty cycle) = 20 log(0.195 ms / 1.055 ms) = -14.7 dB
      Please see page 18 for plotted duty.




Report No.: RF190524D07                      Page No. 15 / 24                        Report Format Version: 6.1.1


CHANNEL                    TX Channel 39            DETECTOR                 Peak (PK)
FREQUENCY RANGE            1GHz ~ 25GHz             FUNCTION                 Average (AV)


                  ANTENNA POLARITY & TEST DISTANCE: HORIZONTAL AT 3 M
                   EMISSION                            ANTENNA     TABLE        RAW       CORRECTION
        FREQ.                    LIMIT     MARGIN
NO.                 LEVEL                               HEIGHT     ANGLE       VALUE        FACTOR
        (MHz)                  (dBuV/m)     (dB)
                   (dBuV/m)                               (m)     (Degree)     (dBuV)        (dB/m)
 1     *2441.00    101.36 PK    114.00     -12.64        1.43 H     5           101.56        -0.20
 2     *2441.00     86.66 AV     94.00      -7.34        1.43 H     5            86.86        -0.20
 3      4882.00    56.42 PK      74.00     -17.58        2.16 H     89           50.26        6.16
 4      4882.00     41.72 AV     54.00     -12.28        2.16 H     89           35.56        6.16
 5      7323.00    58.64 PK      74.00     -15.36        2.85 H     78           45.67        12.97
 6      7323.00     43.94 AV     54.00     -10.06        2.85 H     78           30.97        12.97
                    ANTENNA POLARITY & TEST DISTANCE: VERTICAL AT 3 M
                   EMISSION                            ANTENNA     TABLE        RAW       CORRECTION
        FREQ.                    LIMIT     MARGIN
NO.                 LEVEL                               HEIGHT     ANGLE       VALUE        FACTOR
        (MHz)                  (dBuV/m)     (dB)
                   (dBuV/m)                               (m)     (Degree)     (dBuV)        (dB/m)
 1     *2441.00     92.93 PK    114.00     -21.07        1.03 V     330         93.13         -0.20
 2     *2441.00     78.23 AV     94.00     -15.77        1.03 V     330         78.43         -0.20
 3      4882.00     53.11 PK     74.00     -20.89        1.33 V     280         46.95         6.16
 4      4882.00     38.41 AV     54.00     -15.59        1.33 V     280         32.25         6.16
 5      7323.00     60.55 PK     74.00     -13.45        3.81 V     111         47.58         12.97
 6      7323.00     45.85 AV     54.00      -8.15        3.81 V     111         32.88         12.97
REMARKS:
   1. Emission Level(dBuV/m) = Raw Value(dBuV) + Correction Factor(dB/m)
   2. Correction Factor(dB/m) = Antenna Factor(dB/m) + Cable Factor(dB) – Pre-Amplifier Factor(dB)
   3. Margin value = Emission Level – Limit value
   4. The other emission levels were very low against the limit.
   5. " * ": Fundamental frequency.
   6. The average value of fundamental and harmonic frequency is: Average = Peak value + 20 log(Duty
      cycle) Where the duty factor is calculated from following formula:
      20 log(Duty cycle) = 20 log(0.195 ms / 1.055 ms) = -14.7 dB
      Please see page 18 for plotted duty.




Report No.: RF190524D07                      Page No. 16 / 24                        Report Format Version: 6.1.1


CHANNEL                    TX Channel 77            DETECTOR                 Peak (PK)
FREQUENCY RANGE            1GHz ~ 25GHz             FUNCTION                 Average (AV)


                  ANTENNA POLARITY & TEST DISTANCE: HORIZONTAL AT 3 M
                   EMISSION                            ANTENNA     TABLE        RAW       CORRECTION
        FREQ.                    LIMIT     MARGIN
NO.                 LEVEL                               HEIGHT     ANGLE       VALUE        FACTOR
        (MHz)                  (dBuV/m)     (dB)
                   (dBuV/m)                               (m)     (Degree)     (dBuV)        (dB/m)
 1     *2479.00    101.16 PK    114.00     -12.84        1.59 H     350         101.33        -0.17
 2     *2479.00     86.46 AV     94.00      -7.54        1.59 H     350          86.63        -0.17
 3      2483.50    41.79 PK      74.00     -32.21        1.59 H     350          41.95        -0.16
 4      2483.50     27.09 AV     54.00     -26.91        1.59 H     350          27.25        -0.16
 5      4958.00    56.54 PK      74.00     -17.46        2.80 H     80           50.36        6.18
 6      4958.00     41.84 AV     54.00     -12.16        2.80 H     80           35.66        6.18
 7      7437.00    58.55 PK      74.00     -15.45        2.69 H     91           45.71        12.84
 8      7437.00     43.85 AV     54.00     -10.15        2.69 H     91           31.01        12.84
                    ANTENNA POLARITY & TEST DISTANCE: VERTICAL AT 3 M
                   EMISSION                            ANTENNA     TABLE        RAW       CORRECTION
        FREQ.                    LIMIT     MARGIN
NO.                 LEVEL                               HEIGHT     ANGLE       VALUE        FACTOR
        (MHz)                  (dBuV/m)     (dB)
                   (dBuV/m)                               (m)     (Degree)     (dBuV)        (dB/m)
 1     *2479.00     92.88 PK    114.00     -21.12        1.00 V     334         93.05         -0.17
 2     *2479.00     78.18 AV     94.00     -15.82        1.00 V     334         78.35         -0.17
 3      2483.50     33.51 PK     74.00     -40.49        1.00 V     334         33.67         -0.16
 4      2483.50     18.81 AV     54.00     -35.19        1.00 V     334         18.97         -0.16
 5      4958.00     53.19 PK     74.00     -20.81        1.35 V     267         47.01         6.18
 6      4958.00     38.49 AV     54.00     -15.51        1.35 V     267         32.31         6.18
 7      7437.00     60.43 PK     74.00     -13.57        3.80 V     116         47.59         12.84
 8      7437.00     45.73 AV     54.00      -8.27        3.80 V     116         32.89         12.84
REMARKS:
   1. Emission Level(dBuV/m) = Raw Value(dBuV) + Correction Factor(dB/m)
   2. Correction Factor(dB/m) = Antenna Factor(dB/m) + Cable Factor(dB) – Pre-Amplifier Factor(dB)
   3. Margin value = Emission Level – Limit value
   4. The other emission levels were very low against the limit.
   5. " * ": Fundamental frequency.
   6. The average value of fundamental and harmonic frequency is: Average = Peak value + 20 log(Duty
      cycle) Where the duty factor is calculated from following formula:
      20 log(Duty cycle) = 20 log(0.195 ms / 1.055 ms) = -14.7 dB
      Please see page 18 for plotted duty.




Report No.: RF190524D07                      Page No. 17 / 24                        Report Format Version: 6.1.1


             Duty Cycle




                          20 log(Duty cycle) = 20 log(0.195 ms / 1.055 ms) = -14.7 dB




Report No.: RF190524D07                       Page No. 18 / 24                          Report Format Version: 6.1.1


BELOW 1GHz WORST-CASE DATA
CHANNEL                     TX Channel 39            DETECTOR
                                                                           Quasi-Peak (QP)
FREQUENCY RANGE             9kHz ~ 1GHz              FUNCTION


                             Antenna Polarity & Test Distance : Horizontal at 3 m
                          Emission                           Antenna      Table       Raw        Correction
       Frequency                        Limit     Margin
 No                         Level                             Height      Angle       Value       Factor
         (MHz)                        (dBuV/m)      (dB)
                          (dBuV/m)                              (m)     (Degree)     (dBuV)       (dB/m)
  1        33.59          26.18 QP      40.00      -13.82     1.24 H       120        34.68        -8.50
  2       117.74          23.82 QP      43.50      -19.68     1.05 H       177        33.15        -9.33
  3       272.65          21.49 QP      46.00      -24.51     1.37 H       104        27.38        -5.89
  4       379.93          23.32 QP      46.00      -22.68     1.52 H        17        26.94        -3.62
  5       544.25          27.95 QP      46.00      -18.05     1.42 H       179        28.53        -0.58
  6       662.39          30.78 QP      46.00      -15.22     1.50 H        37        28.78         2.00
REMARKS:
   1. Emission Level(dBuV/m) = Raw Value(dBuV) + Correction Factor(dB/m)
   2. Correction Factor(dB/m) = Antenna Factor(dB/m) + Cable Factor(dB) – Pre-Amplifier Factor(dB)
   3. Margin value = Emission Level – Limit value
   4. The other emission levels were very low against the limit of frequency range 30MHz~1000MHz.
   5. The emission levels were very low against the limit of frequency range 9kHz~30MHz: the amplitude of
      spurious emissions attenuated more than 20 dB below the permissible value to be report.




Report No.: RF190524D07                        Page No. 19 / 24                     Report Format Version: 6.1.1


CHANNEL                     TX Channel 39            DETECTOR
                                                                           Quasi-Peak (QP)
FREQUENCY RANGE             9kHz ~ 1GHz              FUNCTION


                              Antenna Polarity & Test Distance : Vertical at 3 m
                          Emission                           Antenna       Table      Raw        Correction
       Frequency                       Limit      Margin
 No                         Level                             Height       Angle      Value       Factor
         (MHz)                       (dBuV/m)       (dB)
                          (dBuV/m)                             (m)       (Degree)    (dBuV)       (dB/m)
  1       34.03           29.36 QP     40.00       -10.64     1.34 V        263       37.68        -8.32
  2       51.73           23.68 QP     40.00       -16.32     2.38 V        288       30.86        -7.18
  3       143.20          21.50 QP     43.50       -22.00     2.15 V        146       28.63        -7.13
  4       291.27          21.54 QP     46.00       -24.46     2.03 V        163       26.83        -5.29
  5       473.19          26.82 QP     46.00       -19.18     1.74 V        170       28.46        -1.64
  6       627.42          29.71 QP     46.00       -16.29     1.60 V        320       28.10         1.61
REMARKS:
   1. Emission Level(dBuV/m) = Raw Value(dBuV) + Correction Factor(dB/m)
   2. Correction Factor(dB/m) = Antenna Factor(dB/m) + Cable Factor(dB) – Pre-Amplifier Factor(dB)
   3. Margin value = Emission Level – Limit value
   4. The other emission levels were very low against the limit of frequency range 30MHz~1000MHz.
   5. The emission levels were very low against the limit of frequency range 9kHz~30MHz: the amplitude of
      spurious emissions attenuated more than 20 dB below the permissible value to be report.




Report No.: RF190524D07                        Page No. 20 / 24                     Report Format Version: 6.1.1


4.2     Channel Bandwidth
4.2.1    Test Setup


                                                                Spectrum
            EUT
                                        Attenuator              Analyzer


4.2.2    Test Instruments

 Refer to section 4.1.2 to get information of above instrument.



4.2.3    Test Procedure

a. Check the calibration of the measuring instrument using either an internal calibrator or a known signal
   from an external generator.
b. Turn on the EUT and connect it to measurement instrument. Then set it to any one convenient frequency
   within its operating range. Set a reference level on the measuring instrument equal to the highest peak
   value.
c. Measure the frequency difference of two frequencies that were attenuated 20dB from the reference level.
   Record the frequency difference as the emission bandwidth.
d. Repeat above procedures until all frequencies measured were complete.



4.2.4    Deviation from Test Standard

 No deviation.



4.2.5    EUT Operating Condition
The software provided by client enabled the EUT to transmit and receive data at lowest, middle and highest
channel frequencies individually.




Report No.: RF190524D07                              Page No. 21 / 24               Report Format Version: 6.1.1


4.2.6   Test Results


             CHANNEL            FREQUENCY (MHz)          20dB BANDWIDTH (MHz)

                  0                     2402                      1.05
                  39                    2441                      1.02
                  77                    2479                      1.01

                          SPECTRUM PLOT of WORST VALUE




Report No.: RF190524D07           Page No. 22 / 24             Report Format Version: 6.1.1


5    Pictures of Test Arrangements


 Please refer to the attached file (Test Setup Photo).




Report No.: RF190524D07                        Page No. 23 / 24   Report Format Version: 6.1.1


Appendix – Information of the Testing Laboratories

We, Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch, were founded in 1988 to
provide our best service in EMC, Radio, Telecom and Safety consultation. Our laboratories are FCC
recognized accredited test firms and accredited according to ISO/IEC 17025.

If you have any comments, please feel free to contact us at the following:

Lin Kou EMC/RF Lab                                    Hsin Chu EMC/RF/Telecom Lab
Tel: 886-2-26052180                                   Tel: 886-3-6668565
Fax: 886-2-26051924                                   Fax: 886-3-6668323

Hwa Ya EMC/RF/Safety Lab
Tel: 886-3-3183232
Fax: 886-3-3270892

Email: service.adt@tw.bureauveritas.com
Web Site: www.bureauveritas-adt.com

The address and road map of all our labs can be found in our web site also.



--- END ---




Report No.: RF190524D07                       Page No. 24 / 24                  Report Format Version: 6.1.1



Document Created: 2019-06-14 17:28:14