RF Exposure Info (MPE)

FCC ID: EMJHSAP001MP

RF Exposure Info

Download: PDF
FCCID_4246699

                                                     RF Exposure Test Report

                       Report No.: SA190222D16

                             FCC ID: EMJHSAP001MP

                       Test Model: HSA-P001MP

                 Received Date: Feb. 22, 2019

                         Test Date: Mar. 4, 2019

                     Issued Date: Mar. 14, 2019


                         Applicant: PRIMAX ELECTRONICS LTD.

                          Address: No. 669, Ruey Kuang Road, Neihu, Taipei, Taiwan, R.O.C.


                        Issued By: Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch

                    Lab Address: No. 47-2, 14th Ling, Chia Pau Vil., Lin Kou Dist., New Taipei City, Taiwan,
                                 R.O.C.
         FCC Registration /
       Designation Number: 198487 / TW2021




This report is for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted
only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this
report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product
unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you
provided to us. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence, provided,
however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time
shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Unless specific
mention, the uncertainty of measurement has been explicitly taken into account to declare the compliance or non-compliance to the specification.
The report must not be used by the client to claim product certification, approval, or endorsement by any government agencies.

Report No.: SA190222D16                                              Page No. 1 / 11                                            Report Format Version: 6.1.1


                                                                   Table of Contents
Release Control Record .................................................................................................................................. 3
1         Certificate of Conformity...................................................................................................................... 4
2         General Information .............................................................................................................................. 5
    2.1      General Description of EUT ................................................................................................................ 5
3         RF Exposure .......................................................................................................................................... 6
    3.1      Description of Support Units ............................................................................................................... 6
    3.1.1    Configuration of System Under Test.................................................................................................... 6
    3.2      Test Setup ........................................................................................................................................... 7
    3.3      Test Instruments .................................................................................................................................. 7
    3.4      Limits for Maximum Permissible Exposure (MPE) .............................................................................. 8
    3.5      Test Point Description ......................................................................................................................... 8
4         Calculation Result of Maximum Conducted Power........................................................................... 9
5         Photographs of the Test Configuration ............................................................................................. 11




Report No.: SA190222D16                                              Page No. 2 / 11                                             Report Format Version: 6.1.1


                                         Release Control Record


Issue No.             Description                                        Date Issued
SA190222D16           Original release                                   Mar. 14, 2019




Report No.: SA190222D16                     Page No. 3 / 11       Report Format Version: 6.1.1


1    Certificate of Conformity


            Product: OMEN Outpost Mousepad with Qi Wireless Charging

              Brand: hp

        Test Model: HSA-P001MP

    Sample Status: Engineering sample

          Applicant: PRIMAX ELECTRONICS LTD.

          Test Date: Mar. 4, 2019

         Standards: FCC Part 1 (Section 1.1307(b), 1.1310)



The above equipment has been tested by Bureau Veritas Consumer Products Services (H.K.) Ltd.,
Taoyuan Branch, and found compliance with the requirement of the above standards. The test record, data
evaluation & Equipment Under Test (EUT) configurations represented herein are true and accurate accounts
of the measurements of the sample’s RF characteristics under the conditions specified in this report.




     Prepared by :                                                      , Date:          Mar. 14, 2019
                               Annie Chang / Senior Specialist




     Approved by :                                                      , Date:          Mar. 14, 2019
                           Rex Lai / Associate Technical Manager




Report No.: SA190222D16                       Page No. 4 / 11                         Report Format Version: 6.1.1


2     General Information
2.1    General Description of EUT

 Product                          OMEN Outpost Mousepad with Qi Wireless Charging
 Brand                            hp
 Test Model                       HSA-P001MP
 Sample Status                    Engineering sample
                                  Input: 5Vdc, 3A,
 Rating
                                  Output: 5W
 Modulation Type                  FSK
 Operating Frequency              111-148kHz
 Antenna Type                     Coil antenna
 Field Strength                   79.00dBuV/m
 Dimensions                       14.86cm2 (diameter = 435mm)
 Accessory Device                 USB-C to two USB-A Dongle (with two USB cables (0.15m each))
 Data Cable Supplied              Shielded USB type C cable (1.2m) attached on EUT
 Maximum Power Output from
                                  5W
 the Charging Coil
Note:
1. The EUT is an OMEN Outpost Mousepad with Qi Wireless Charging with Qi charging function.
2. EUT has been pre-tested under following test modes, and test mode 1 was the worst case for final test.
           Mode                                         Test Condition
            1         EUT Link to System (via USB Type C cable)
            2         EUT Link to System (via USB-C to two USB-A Dongle)
3. The above EUT information is declared by manufacturer and for more detailed features description,
   please refer to the manufacturer's specifications or user's manual.




Report No.: SA190222D16                      Page No. 5 / 11                       Report Format Version: 6.1.1


3        RF Exposure
3.1       Description of Support Units
The EUT has been tested as an independent unit together with other necessary accessories or support units.
The following support units or accessories were used to form a representative test configuration during the
tests.
    ID        Product                Brand                Model No.           Serial No.       FCC ID                Remarks
    A.         Load                   N/A                    N/A                 N/A             N/A             Supplied by client
    B.      Notebook PC             Lenovo             20L6-S4GW00            PF1EZSA2           N/A             Provided by Lab
Note: All power cords of the above support units are non-shielded (1.8m).


    ID      Descriptions              Qty.               Length (m)       Shielding (Yes/No)   Cores (Qty.)          Remarks
    1.    USB Type C cable              1                    1.2                   N                0            Supplied by client
Note: The core(s) is(are) originally attached to the cable(s).




3.1.1      Configuration of System Under Test

Charging Mode with Load:



                                                                   Load (A)


                                         1                                          USB
            Notebook PC (B)                      USB Type C         EUT
                  120Vac




Standby Mode:




                                         1                                          USB
            Notebook PC (B)                      USB Type C         EUT
                  120Vac




Report No.: SA190222D16                                     Page No. 6 / 11                              Report Format Version: 6.1.1


3.2     Test Setup




                                                 15 cm / 20cm




                                                                              EUT

                      Field Probe




Note: Measurements should be made from all sides and the top of the primary/client pair, with the 15 cm or
     20 cm measured from the center of the probe(s) to the edge of the device.

3.3     Test Instruments

       Description         Brand     Model No.     Frequency Range Calibrated Date Calibrated Until
  Broadband Field
                          NARDA       NBM-550                  -       Mar. 28, 2018      Mar. 27, 2020
       Meter
   Magnetic Field
                          NARDA       ELT-400          1 – 400kHz       Apr. 12, 2018     Apr. 11, 2020
      Meter
  Magnetic Probe          NARDA       HF-3061       300kHz – 30MHz      Apr. 16, 2018     Apr. 15, 2020
  Magnetic Probe          NARDA       HF-0191        27 – 1000MHz       Apr. 17, 2018     Apr. 16, 2020
  Broadband Field
                          NARDA       NBM-550                  -       Mar. 28, 2018      Mar. 27, 2020
       Meter
Electric Field Meter COMBINOVA        EFM 200         5Hz – 400kHz      Dec. 6, 2017      Dec. 5, 2019
      E-Field Probe       NARDA       EF-0391        100kHz – 3GHz     Mar. 28, 2018      Mar. 27, 2020
      E-Field Probe       NARDA       EF-6091      100MHz – 60GHz        Mar. 29, 2018  Mar. 28, 2020
NOTE: 1. The calibration interval of the above test instruments is 12/24 months and the
          calibrations are traceable to NML/ROC and NIST/USA.
      2. The test was performed in Chia Pau RF Chamber




Report No.: SA190222D16                      Page No. 7 / 11                         Report Format Version: 6.1.1


3.4    Limits for Maximum Permissible Exposure (MPE)
§ 1.1310 The criteria listed in table 1 shall be used to evaluate the environmental impact of
  human exposure to radiofrequency(RF) radiation as specified in § 1.1307(b), except in the case of portable
  devices which shall be evaluated according to the provisions of § 2.1093 of this chapter.




680106 D01 RF Exposure Wireless Charging App v03
The aggregate H-field strengths at 15 cm surrounding the device and 20 cm above the top surface from all
simultaneous transmitting coils are demonstrated to be less than 50% of the MPE limit.

3.5    Test Point Description



                          Z-axis (Above)
                                       Top




      Left                                       Right




                 Bottom




Report No.: SA190222D16                      Page No. 8 / 11                        Report Format Version: 6.1.1


4      Calculation Result of Maximum Conducted Power
Charging Mode with 10% Load (at center)
                                           E-Field Measurement
        Distance                                      15cm                                          20cm
       EUT Side             Left            Right                Top          Bottom               Z-axis
    Max E-field (V/m)      1.1900          0.5300               1.1300        5.1400               2.3300
       Limit (V/m)          614             614                  614           614                   614
      Margin (V/m)        -612.8100       -613.4700            -612.8700    -608.8600            -611.6700
    50 % Limit (V/m)        307             307                  307           307                   307
50 % Margin (V/m)         -305.8100       -306.4700            -305.8700    -301.8600            -304.6700

                                           H-Field Measurement
        Distance                                      15cm                                          20cm
       EUT Side             Left            Right                Top          Bottom               Z-axis
    Max H-field (uT)       0.1110          0.1010               0.1320        0.1290               0.1980
    Max H-field (A/m)      0.0888          0.0808               0.1056        0.1032               0.1584
       Limit (A/m)          1.63            1.63                 1.63          1.63                 1.63
      Margin (A/m)         -1.5412         -1.5492              -1.5244      -1.5268              -1.4716
    50 % Limit (A/m)       0.815            0.815                0.815        0.815                0.815
50 % Margin (A/m)       -0.7262            -0.7342           -0.7094          -0.7118           -0.6566
Measurements were made from all sides and the top of the primary/client pair, with the 15 cm or 20 cm
measured from the center of the probe(s) to the edge of the device. The highest emission level was recorded.

Charging Mode with 50% Load (at center)
                                           E-Field Measurement
        Distance                                      15cm                                          20cm
       EUT Side             Left            Right                Top          Bottom               Z-axis
    Max E-field (V/m)      1.1500          0.5100               1.0400        4.7300               2.1400
       Limit (V/m)          614             614                  614           614                   614
      Margin (V/m)        -612.8500       -613.4900            -612.9600    -609.2700            -611.8600
    50 % Limit (V/m)        307             307                  307           307                   307
50 % Margin (V/m)         -305.8500       -306.4900            -305.9600    -302.2700            -304.8600

                                           H-Field Measurement
        Distance                                      15cm                                          20cm
       EUT Side             Left            Right                Top          Bottom               Z-axis
    Max H-field (uT)       0.1060          0.0990               0.1180        0.1110               0.1650
    Max H-field (A/m)      0.0848          0.0792               0.0944        0.0888               0.1320
       Limit (A/m)          1.63            1.63                 1.63          1.63                 1.63
      Margin (A/m)         -1.5452         -1.5508              -1.5356      -1.5412              -1.4980
    50 % Limit (A/m)       0.815            0.815                0.815        0.815                0.815
50 % Margin (A/m)       -0.7302            -0.7358           -0.7206          -0.7262           -0.6830
Measurements were made from all sides and the top of the primary/client pair, with the 15 cm or 20 cm
measured from the center of the probe(s) to the edge of the device. The highest emission level was recorded.


Report No.: SA190222D16                      Page No. 9 / 11                          Report Format Version: 6.1.1


Charging Mode with Full Load (at center)
                                            E-Field Measurement
      Distance                                         15cm                                          20cm
     EUT Side               Left             Right                 Top        Bottom                Z-axis
 Max E-field (V/m)         0.8100           0.4800                0.8200      4.9500                2.0200
     Limit (V/m)            614              614                   614         614                    614
   Margin (V/m)           -613.1900        -613.5200             -613.1800   -609.0500            -611.9800
  50 % Limit (V/m)          307              307                   307         307                    307
50 % Margin (V/m)         -306.1900        -306.5200             -306.1800   -302.0500            -304.9800

                                            H-Field Measurement
      Distance                                         15cm                                          20cm
     EUT Side               Left             Right                 Top        Bottom                Z-axis
  Max H-field (uT)         0.1030           0.0970                0.1150      0.1090                0.1580
 Max H-field (A/m)         0.0824           0.0776                0.0920      0.0872                0.1264
     Limit (A/m)            1.63             1.63                  1.63        1.63                  1.63
   Margin (A/m)            -1.5476          -1.5524               -1.5380     -1.5428              -1.5036
  50 % Limit (A/m)         0.815             0.815                 0.815       0.815                0.815
50 % Margin (A/m)       -0.7326            -0.7374           -0.7230          -0.7278           -0.6886
Measurements were made from all sides and the top of the primary/client pair, with the 15 cm or 20 cm
measured from the center of the probe(s) to the edge of the device. The highest emission level was recorded.


Standby Mode
                                            E-Field Measurement
      Distance                                         15cm                                          20cm
     EUT Side               Left             Right                 Top        Bottom                Z-axis
 Max E-field (V/m)         0.6500           0.4100                0.9100      5.1700                1.3000
     Limit (V/m)            614              614                   614         614                    614
   Margin (V/m)           -613.3500        -613.5900             -613.0900   -608.8300            -612.7000
  50 % Limit (V/m)          307              307                   307         307                    307
50 % Margin (V/m)         -306.3500        -306.5900             -306.0900   -301.8300            -305.7000

                                            H-Field Measurement
      Distance                                         15cm                                          20cm
     EUT Side               Left             Right                 Top        Bottom                Z-axis
  Max H-field (uT)         0.1040           0.1020                0.1070      0.1090                0.1150
 Max H-field (A/m)         0.0832           0.0816                0.0856      0.0872                0.0920
     Limit (A/m)            1.63             1.63                  1.63        1.63                  1.63
   Margin (A/m)            -1.5468          -1.5484               -1.5444     -1.5428              -1.5380
  50 % Limit (A/m)         0.815             0.815                 0.815       0.815                0.815
50 % Margin (A/m)       -0.7318            -0.7334           -0.7294          -0.7278           -0.7230
Measurements were made from all sides and the top of the primary/client pair, with the 15 cm or 20 cm
measured from the center of the probe(s) to the edge of the device. The highest emission level was recorded.


Report No.: SA190222D16                       Page No. 10 / 11                         Report Format Version: 6.1.1


5    Photographs of the Test Configuration

Please refer to the attached file (Test Setup Photo).



--- END ---




Report No.: SA190222D16                        Page No. 11 / 11   Report Format Version: 6.1.1



Document Created: 2019-04-22 20:48:59
Document Modified: 2019-04-22 20:48:59

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC