DCD

FCC ID: EMJC50-6AT05

Test Report

Download: PDF
FCCID_2117110

                                                              Report No: C130527Z02-RP1


             FCC 47 CFR PART 15 SUBPART C
                                   TEST REPORT

                                          for

                                 TX wireless charger
                                   Model: 50-6AT05
                             Trade Name: Philips/Primax
                                 Test Report Number:
                                   C130527Z02-RP1

                                       Issued for:

                               Primax Electronics Ltd.
              No.669, Ruey Kuang Road, Neihu, Taipei, Taiwan, R.O.C

                                       Issued by

           COMPLIANCE CERTIFICATION SERVICES (SHENZHEN) INC.

          No.10-1, Mingkeda Logistics Park, No.18, Huanguan South Rd.,
                Guan Lan Town, Baoan District, Shenzhen, China
                                TEL: 86-755-28055000
                                FAX: 86-755-28055221
                              Issued Date: July 8, 2013




Note: This report shall not be reproduced except in full, without the written approval of
Compliance Certification Services Inc. This document may be altered or revised by
Compliance Certification Services Inc. personnel only, and shall be noted in the revision
section of the document. The client should not use it to claim product endorsement by
TAF, A2LA, NVLAP, NIST or any government agencies. The test result of this report
relate only to the tested sample identified in this report.




FCC ID: EMJC50-6AT05                                                          Page 1 / 18


                                                                                     Report No: C130527Z02-RP1

                                                Revision History

                      Issue                                                           Effect
  Rev.                 No.                              Revisions                     Page           Revised By
   00      C130527Z02-RP1                              Initial Issue                    ALL           Nancy Fu




FCC ID: EMJC50-6AT05                                                                                      Page 2 / 18
This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


                                                                                                 Report No: C130527Z02-RP1
                                           TABLE OF CONTENTS
1    TEST RESULT CERTIFICATION .....................................................................................4

2    EUT DESCRIPTION..........................................................................................................5

3    TEST METHODOLOGY....................................................................................................6
    3.1.    EUT CONFIGURATION............................................................................................6
    3.2.    EUT EXERCISE........................................................................................................6
    3.3.    GENERAL TEST PROCEDURES.............................................................................6
    3.4.    FCC PART 15.205 RESTRICTED BANDS OF OPERATIONS .................................7
    3.5.    DESCRIPTION OF TEST MODES............................................................................7

4    INSTRUMENT CALIBRATION .........................................................................................8
    4.1.    MEASURING INSTRUMENT CALIBRATION ...........................................................8
    4.2.    MEASUREMENT EQUIPMENT USED .....................................................................8

5    FACILITIES AND ACCREDITATIONS .............................................................................9
    5.1.    FACILITIES...............................................................................................................9
    5.2.    EQUIPMENT.............................................................................................................9
    5.3.    TABLE OF ACCREDITATIONS AND LISTINGS.......................................................9
    5.4.    MEASUREMENT UNCERTAINTY..........................................................................10

6    SETUP OF EQUIPMENT UNDER TEST ........................................................................11
    6.1.    SETUP CONFIGURATION OF EUT .......................................................................11
    6.2.    SUPPORT EQUIPMENT ........................................................................................11

7    FCC PART 15.209 REQUIREMENTS ............................................................................12
    7.1.    RADIATED EMISSIONS .........................................................................................12
    7.2.    POWERLINE CONDUCTED EMISSIONS..............................................................17




FCC ID: EMJC50-6AT05                                                                                                     Page 3 / 18
This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


                                                                                     Report No: C130527Z02-RP1

1 TEST RESULT CERTIFICATION
Product               TX wireless charger
Model                 50-6AT05
Brand                 Philips/Primax
Tested                May 27~July 5, 2013
Applicant             Primax Electronics Ltd.
                      No.669, Ruey Kuang Road, Neihu, Taipei, Taiwan, R.O.C
Manufacturer          Dongguan Primax Electronic & Telecommunication Products Ltd.
                      (1). Liu Wu District, Shek Kit Town, Dongguan City, Guang Dong Province, P.R.China
                      (2).YuHong Industrial Zone, ChenDong, ShekKit Town, DongGuan City, GuangDong,
                          P.R.China


                                        APPLICABLE STANDARDS
                     STANDARD                                                    TEST RESULT
        FCC 47 CFR Part 15 Subpart C                                      No non-compliance noted


We hereby certify that:
The above equipment was tested by Compliance Certification Services Inc. The test data,
data evaluation, test procedures, and equipment configurations shown in this report
were made in accordance with the procedures given in ANSI C63.4: 2009 and the
energy emitted by the sample tested as described in this report is in compliance with the
requirements of FCC Rules Part 15.207, 15.209..
The test results of this report relate only to the tested sample identified in this report.



Approved by:                                                   Reviewed by:




Tom Gan                                                        Ruby Zhang
Supervisor of EMC Dept.                                        Supervisor of Report Dept.
Compliance Certification Service Inc.                          Compliance Certification Service Inc.




FCC ID: EMJC50-6AT05                                                                                      Page 4 / 18
This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


                                                                                     Report No: C130527Z02-RP1

2 EUT DESCRIPTION
  Product                                    TX wireless charger
  Model Number                               50-6AT05
  Brand                                      Philips/Primax
  Model Discrepancy                          N/A
  Identify Number                            C130527Z02-RP1
  Power Supply                               DC5V Supplied by the adapter
                            Dongguan City Yingju Electronics Co., Ltd./
 Adapter Manufacturer/Model YJC010C-0502000U
 Name                       I/P: 100-240Vac, 50/60Hz, 350mA
                            O/P: 5Vdc, 2000mA
  Received Date                              May 27, 2013
  Operating Frequency Range 112kHz-205kHz
  Antenna Specification                     Coil antenna
  Temperature Range                          0°C ~ +45°C

Remark:
      1.    The sample selected for test was engineering sample that approximated to
            production product and was provided by manufacturer.
      2.    This submittal(s) (test report) is intended for FCC ID: EMJC50-6AT05 filing to
            comply with Section 15.209 of the FCC Part 15, Subpart C Rules.




FCC ID: EMJC50-6AT05                                                                                      Page 5 / 18
This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


                                                                                     Report No: C130527Z02-RP1
3 TEST METHODOLOGY
The tests documented in this report were performed in accordance with ANSI C63.4
(2003) and FCC CFR 47 Part 2, 15.207, 15.209.

3.1. EUT CONFIGURATION
The EUT configuration for testing is installed on RF field strength measurement to meet
the Commissions requirement and operating in a manner that intends to maximize its
emission characteristics in a continuous normal application.

3.2. EUT EXERCISE
The EUT was operated in the engineering mode to fix the TX frequency that was for the
purpose of the measurements.

3.3. GENERAL TEST PROCEDURES
Conducted Emissions
The EUT is placed on the turntable, which is 0.8 m above ground plane. According to the
requirements in Section 13.1.4.1 of ANSI C63.4 (2003). Conducted emissions from the
EUT measured in the frequency range between 0.15 MHz and 30MHz using CISPR
Quasi-peak and average detector modes.

Radiated Emissions
The EUT is placed on a turn table, which is 0.8 m above ground plane. The turntable
shall rotate 360 degrees to determine the position of maximum emission level. EUT is
set 3m away from the receiving antenna, which varied from 1m to 4m to find out the
highest emission. And also, each emission was to be maximized by changing the
polarization of receiving antenna both horizontal and vertical. In order to find out the
maximum emissions, exploratory radiated emission measurements were made
according to the requirements in Section 13.1.4.1 of ANSI C63.4 (2003).




FCC ID: EMJC50-6AT05                                                                                      Page 6 / 18
This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


                                                                                     Report No: C130527Z02-RP1

3.4. FCC PART 15.205 RESTRICTED BANDS OF OPERATIONS
(a) Except as shown in paragraph (d) of this section, only spurious emissions are
    permitted in any of the frequency bands listed below:

                 MHz                           MHz                         MHz                     GHz
            0.090 - 0.110      16.42 - 16.423     399.9 - 410                                  4.5 - 5.15
           1
            0.495 - 0.505   16.69475 - 16.69525    608 - 614                                  5.35 - 5.46
          2.1735 - 2.1905   16.80425 - 16.80475   960 - 1240                                  7.25 - 7.75
           4.125 - 4.128         25.5 - 25.67     1300 - 1427                                 8.025 - 8.5
         4.17725 - 4.17775       37.5 - 38.25    1435 - 1626.5                                  9.0 - 9.2
         4.20725 - 4.20775         73 - 74.6    1645.5 - 1646.5                                 9.3 - 9.5
           6.215 - 6.218         74.8 - 75.2      1660 - 1710                                 10.6 - 12.7
         6.26775 - 6.26825      108 - 121.94    1718.8 - 1722.2                               13.25 - 13.4
         6.31175 - 6.31225        123 - 138       2200 - 2300                                 14.47 - 14.5
           8.291 - 8.294       149.9 - 150.05     2310 - 2390                                 15.35 - 16.2
           8.362 - 8.366        156.52475 -      2483.5 - 2500                                17.7 - 21.4
         8.37625 - 8.38675        156.52525       2655 - 2900                                22.01 - 23.12
         8.41425 - 8.41475      156.7 - 156.9     3260 - 3267                                 23.6 - 24.0
           12.29 - 12.293    162.0125 - 167.17    3332 - 3339                                 31.2 - 31.8
        12.51975 - 12.52025    167.72 - 173.2    3345.8 - 3358                                36.43 - 36.5
        12.57675 - 12.57725       240 - 285       3600 - 4400                                       ( 2)
           13.36 - 13.41         322 - 335.4
    1
        Until February 1, 1999, this restricted band shall be 0.490-0.510 MHz.
    2
        Above 38.6

(b) Except as provided in paragraphs (d) and (e), the field strength of emissions
    appearing within these frequency bands shall not exceed the limits shown in Section
    15.209. At frequencies equal to or less than 1000 MHz, compliance with the limits in
    Section 15.209 shall be demonstrated using measurement instrumentation
    employing a CISPR quasi-peak detector. Above 1000 MHz, compliance with the
    emission limits in Section 15.209 shall be demonstrated based on the average value
    of the measured emissions. The provisions in Section 15.35 apply to these
    measurements.

3.5. DESCRIPTION OF TEST MODES
The EUT (model: 50-6AT05) had been tested under operating condition.
Test program used to control the EUT for staying in continuous transmitting mode was
programmed.
After verification,all tests were carried out with the worst case test modes as shown below 1GHz.
RF ID: Channel 175kHz was chosen for full testing.




FCC ID: EMJC50-6AT05                                                                                      Page 7 / 18
This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


                                                                                      Report No: C130527Z02-RP1

4 INSTRUMENT CALIBRATION
4.1. MEASURING INSTRUMENT CALIBRATION
The measuring equipment, which was utilized in performing the tests documented herein,
has been calibrated in accordance with the manufacturer's recommendations for utilizing
calibration equipment, which is traceable to recognized national standards.

4.2. MEASUREMENT EQUIPMENT USED
Equipment Used for Emissions Measurement
                      Radiated Emission Test Site 966(2)
                                                                           Serial             Last             Due
Name of Equipment             Manufacturer        Model Number
                                                                          Number           Calibration      Calibration
 PSA Series Spectrum
                                   Agilent              E4446A          US44300399          03/09/2013       03/08/2014
     Analyzer
 EMI TEST RECEIVER          ROHDE&SCHWARZ                ESCI              100783           03/09/2013       03/08/2014
         Amplifier                 MITEQ            AM-1604-3000           1123808          03/18/2013       03/18/2014
   High Noise Amplifier            Agilent              8449B            3008A01838         03/18/2013       03/18/2014
    Board-Band Horn
                                Schwarzbeck           BBHA 9170           9170-497          06/21/2013       06/21/2014
        Antenna
      Bilog Antenna            SCHAFFNER               CBL6143               5082           03/02/2013       03/01/2014
      Horn Antenna           SCHWARZBECK              BBHA9120               D286           03/02/2013       03/01/2014
      Loop Antenna                A、R、A               PLA-1030/B             1029           03/23/2013       03/23/2014
       Turn Table                    N/A                  N/A                N/A               N.C.R            N.C.R
        Controller            Sunol Sciences            SC104V            022310-1             N.C.R            N.C.R
        Controller                   CT                   N/A                N/A               N.C.R            N.C.R
 Temp. / Humidity Meter           Anymetre               JR913               N/A            03/04/2013       03/03/2014
        Test S/W                   FARAD                                    LZ-RF / CCS-SZ-3A2
NOTE: 1. The calibration interval of the above test instruments is 12 months and the calibrations are
         traceable to NML/ROC and NIST/USA.
      2. The FCC Site Registration number is 101879.
      3. N.C.R = No Calibration Required.

                                       Conducted Emission Test Site
      Name of                                                                                  Last        Due
                            Manufacturer           Model Number          Serial Number
     Equipment                                                                              Calibration Calibration
EMI TEST RECEIVER ROHDE&SCHWARZ                          ESCI                 100783          03/09/2013      03/08/2014
      LISN(EUT)           ROHDE&SCHWARZ                 ENV216              101543-WX         04/20/2013      04/19/2014
         LISN                    EMCO                   3825/2              8901-1459         03/09/2013      03/08/2014
Temp. / Humidity Meter          VICTOR                   HTC-1                  N/A           03/04/2013      03/03/2014
       Test S/W                 FARAD                                     EZ-EMC/ CCS-3A1-CE
NOTE: 1. The calibration interval of the above test instruments is 12 months and the calibrations are
         traceable to NML/ROC and NIST/USA.
      2. N.C.R = No Calibration Request.




FCC ID: EMJC50-6AT05                                                                                       Page 8 / 18
This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


                                                                                     Report No: C130527Z02-RP1
5 FACILITIES AND ACCREDITATIONS
5.1. FACILITIES
All measurement facilities used to collect the measurement data are located at
No.10-1, Mingkeda Logistics Park, No.18, Huanguan South Rd., Guan Lan Town,
Baoan District, Shenzhen, China

The sites are constructed in conformance with the requirements of ANSI C63.7, ANSI
C63.4 (2003) and CISPR Publication 22.

5.2. EQUIPMENT
Radiated emissions are measured with one or more of the following types of linearly
polarized antennas: tuned dipole, biconical, log periodic, bi-log, and/or ridged waveguide,
horn. Spectrum analyzers with pre-selectors and quasi-peak detectors are used to
perform radiated measurements.
Conducted emissions are measured with Line Impedance Stabilization Networks and
EMI Test Receivers.
Calibrated wideband preamplifiers, coaxial cables, and coaxial attenuators are also used
for making measurements.
All receiving equipment conforms to CISPR Publication 16-1, “Radio Interference
Measuring Apparatus and Measurement Methods.”


5.3. TABLE OF ACCREDITATIONS AND LISTINGS
Our laboratories are accredited and approved by the following accreditation body
according to ISO/IEC 17025.
              USA                A2LA
              China              CNAS
The measuring facility of laboratories has been authorized or registered by the following
approval agencies.
              USA               FCC
              Japan             VCCI(C-3478, R-3135, T-652, G-624)
              Canada            INDUSTRY CANADA
              Taiwan            BSMI
              Norway            Nemko
Copies of granted accreditation certificates are available for downloading from our web
site, http://www.ccsrf.com




FCC ID: EMJC50-6AT05                                                                                      Page 9 / 18
This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


                                                                                     Report No: C130527Z02-RP1

5.4. MEASUREMENT UNCERTAINTY
                             Parameter                                            Uncertainty
               Radiated Emission, 30 to 200 MHz
                                                                                   +/-3.6880dB
                       Test Site : 966(2)
              Radiated Emission, 200 to 1000 MHz
                                                                                   +/-3.6695dB
                       Test Site : 966(2)
                Radiated Emission, 1 to 8 GHz                                      +/-5.1782dB
                   Radiated Emission, 8 to 18 GHz                                  +/-5.2173dB
                       Conducted Emissions                                         +/-3.6836dB
                            Band Width                                                178kHz
                      Peak Output Power MU                                         +/-1.906dB
                           Band Edge MU                                            +/-0.182dB
                      Channel Separation MU                                         416.178Hz
                          Duty Cycle MU                                              0.054ms
                      Frequency Stability MU                                          226Hz
This uncertainty represents an expanded uncertainty expressed at approximately the
95% confidence level using a coverage factor of k=2.
The measured result is above (below) the specification limit by a margin less than the
measurement uncertainty; it is therefore not possible to state compliance based on the
95% level of confidence. However, the result indicates that compliance (non-compliance)
is more probable than non-compliance) with the specification limit.




FCC ID: EMJC50-6AT05                                                                                      Page 10 / 18
This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


                                                                                      Report No: C130527Z02-RP1

6 SETUP OF EQUIPMENT UNDER TEST
6.1. SETUP CONFIGURATION OF EUT
See test photographs attached in Appendix 1 for the actual connections between EUT
and support equipment.

6.2. SUPPORT EQUIPMENT
 No.     Equipment          Model No.           Serial No.      FCC ID        Brand       Data Cable       Power Cord
         Windows
   1                       Lumia 920               N/A            N/A          N/A            N/A              N/A
          Phone
Remark: Grounding was established in accordance with the manufacturer’s requirements and
       conditions for the intended use.




FCC ID: EMJC50-6AT05                                                                                      Page 11 / 18
This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


                                                                                     Report No: C130527Z02-RP1

7 FCC PART 15.209 REQUIREMENTS
7.1. RADIATED EMISSIONS
LIMIT
1. According to §15.209(a), except as provided elsewhere in this Subpart, the emissions
   from an intentional radiator shall not exceed the field strength levels specified in the
   following table:

                                                    Field Strength                  Measurement Distance
            Frequency (MHz)
                                                        (μV/m)                              (m)
                0.009–0.490                           2400/F(kHz)                                  300
                0.490–1.705                          24000/F(kHz)                                   30
                 1.705–30.0                                  30                                     30
                    30–88                                  100**                                    3
                   88–216                                  150**                                    3
                  216–960                                  200**                                    3
                 Above 960                                  500                                     3
    Remark: Except as provided in paragraph (g), fundamental emissions from
    intentional radiators operating under this Section shall not be located in the frequency
    bands 54-72 MHz, 76-88 MHz, 174-216 MHz or 470-806 MHz. However, operation
    within these frequency bands is permitted under other sections of this Part, e.g.,
    Sections 15.231 and 15.241.
2. In the emission table above, the tighter limit applies at the band edges.
                                                    Field Strength                        Field Strength
             Frequency (Hz)
                                                  (μV/m at 3-meter)                    (dBμV/m at 3-meter)
                     30-88                                100                                   40
                    88-216                                  150                                   43.5
                   216-960                                  200                                     46
                 Above 960                                  500                                     54




FCC ID: EMJC50-6AT05                                                                                      Page 12 / 18
This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


                                                                                     Report No: C130527Z02-RP1

TEST CONFIGURATION
9kHz ~ 30MHz

                                                                                       Antenna
                                                                                        tower


                                     3m
                                                                                          Loop antenna
         EUT
                                       4m
                                                                                       Spectrum /
                                                                                        Receiver


                Turntable                   1m
                              0.8m
                                                                                      Pre-amp




    Reference ground plane




30MHz ~ 1 GHz

                                                                                     Antenna
                                                                                      tower


                               3m                                                     Bi-log
                                                                                     antenna
         EUT
                                      4m
                                                                                   Spectrum
                                                                                   analyzer


                Turntable                   1m
                             0.8m




    Reference ground plane




FCC ID: EMJC50-6AT05                                                                                      Page 13 / 18
This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


                                                                                     Report No: C130527Z02-RP1


TEST PROCEDURE
For 9kHz ~ 30MHz
1. The EUT is placed on a turntable, which is 0.8m above ground plane.
2. The turntable shall be rotated for 360 degrees to determine the position of maximum
    emission level.
3. EUT is set 3m away from the receiving antenna, The center of the loop shall be 1 m
    above the ground then to find out the highest emissions.
4. Maximum procedure was performed on the six highest emissions to ensure EUT
    compliance.
5. And also, each emission was to be maximized by rotated of receiving antenna axis
6. Set the spectrum analyzer in the following setting as:
    RBW=10kHz / VBW=30kHz / Sweep=AUTO
7. Repeat above procedures until the measurements for all frequencies are complete.

For 30MHz ~ 1GHz
1. The EUT is placed on a turntable, which is 0.8m above ground plane.
2. The turntable shall be rotated for 360 degrees to determine the position of maximum
    emission level.
3. EUT is set 3m away from the receiving antenna, which is varied from 1m to find out
    the highest emissions.
4. Maximum procedure was performed on the six highest emissions to ensure EUT
     compliance.
5. And also, each emission was to be maximized by changing the polarization of
    receiving
    antenna both horizontal and vertical.
6. Set the spectrum analyzer in the following setting as:
    RBW=100kHz / VBW=300kHz / Sweep=AUTO
7. Repeat above procedures until the measurements for all frequencies are complete.


TEST RESULTS
No non-compliance noted.




FCC ID: EMJC50-6AT05                                                                                      Page 14 / 18
This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


                                                                                     Report No: C130527Z02-RP1

TEST DATA
Operation Mode:               TX mode                       Test Date:                     July 5, 2013
Temperature:                  24°C                          Tested by:                     Mack Li
Humidity:                     52 % RH                       Polarity:                      Ver. / Hor.


                                    Correction
Frequency         Reading                                Result           Limit 3m         Margin      Detector Mode
                                     Factor
  (MHz)           (dBuV)                               (dBuV/m)          (dBuV/m)           (dB)        (PK/QP/AVG)
                                     (dB/m)
   0.0142           35.29             82.46              117.75            122.26           -4.51            Peak
   0.0687           24.95              70.49              95.44            100.69           -5.25            Peak
   0.1023           22.45              66.31              88.76            95.24            -6.48            Peak
   0.1500           23.64              62.70              86.34            90.00            -3.66            Peak
   3.4334           14.59              40.29              54.88            69.50           -14.62            Peak
  7.1150          14.76            34.71            49.47         69.50          -20.03        Peak
Remark: 1. Measuring frequencies from 9kHz to the 30MHz.
         2. Radiated emissions measured in frequency range from 9kHz to 1000MHz were made with an
         instrument using peak/quasi-peak/average detector mode.
         3. Measurements above show only up to 6 maximum emissions noted, or would be lesser, with
         “ N/A ” remark, if no specific emissions from the EUT are recorded (ie: margin>20dB from the
         applicable limit) and considered that's already beyond the background noise floor.
         4. Margin (dB) = Result (dBuV/m) – Limit (dBuV/m).




FCC ID: EMJC50-6AT05                                                                                      Page 15 / 18
This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


                                                                                     Report No: C130527Z02-RP1

Operation Mode:            Normal Link                        Test Date:                   June 5, 2013
Temperature:               24oC                               Tested by:                   Mack Li
Humidity:                  52 % RH                            Polarity:                    Ver. / Hor.

  Frequency         Reading       Correction   Result   Limit                    Margin       Antenna       Remark
    (MHz)           (dBμV)         Factor    (dBμV/m) (dBμV/m)                    (dB)         Pole
                                   (dB/m)                                                      (V/H)
    41.3167           52.65         -14.73     37.92    40.00                     -2.08          V             QP
   199.7500           45.74          -18.72          27.02          43.50        -16.48           V            QP
   409.9166           32.91          -15.24          17.67          46.00        -28.33           V            QP
   539.2500           33.11          -14.14          18.97          46.00        -27.03           V            QP
   717.0833           33.63          -10.92          22.71          46.00        -23.29           V            QP
   776.9000           33.33          -11.31          22.02          46.00        -23.98           V            QP

    60.7167           45.17          -21.49          23.68          40.00        -16.32           H            QP
   202.9832           50.02          -18.43          31.59          43.50         -11.91          H            QP
   361.4166           36.73          -16.78          19.95          46.00        -26.05           H            QP
   506.9167           33.07          -14.46          18.61          46.00        -27.39           H            QP
   605.5333           33.56          -12.58          20.98          46.00        -25.02           H            QP
   684.7500           32.92          -11.04          21.88          46.00        -24.12           H            QP
Remark:1. Measuring frequencies from 30 MHz to the 1GHz.
       2. Radiated emissions measured in frequency range from 30 MHz to 1000MHz were
          made with an instrument using Peak detector mode.
       3. Data of measurement within this frequency range shown “ --- ” in the table above means
          the reading of emissions are attenuated more than 20dB below the permissible limits or
          the field strength is too small to be measured.
       4. The IF bandwidth of receiver between 30MHz to 1GHz was 100kHz.




FCC ID: EMJC50-6AT05                                                                                      Page 16 / 18
This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


                                                                                     Report No: C130527Z02-RP1

7.2. POWERLINE CONDUCTED EMISSIONS
LIMIT
For an intentional radiator which is designed to be connected to the public utility (AC)
power line, the radio frequency voltage that is conducted back onto the AC power line on
any frequency or frequencies within the band 150 kHz to 30 MHz shall not exceed 250
microvolts (The limit decreases linearly with the logarithm of the frequency in the range 0.15 MHz
to 0.50 MHz). The limits at specific frequency range is listed as follows:

                                                                             Limits
        Frequency Range                                                     (dBμV)
             (MHz)
                                                     Quasi-peak                                Average
             0.15 to 0.50                               66 to 56*                              56 to 46*
               0.50 to 5                                    56                                      46
                5 to 30                                     60                                      50
Compliance with this provision shall be based on the measurement of the radio
frequency voltage between each power line (LINE and NEUTRAL) and ground at the
power terminals.

TEST CONFIGURATION
 See test photographs attached in Appendix I for the actual connections between EUT
 and support equipment.

TEST PROCEDURE
 1. The EUT was placed on a table, which is 0.8m above ground plane.
 2. Maximum procedure was performed on the six highest emissions to ensure EUT
    compliance.
 3. Repeat above procedures until all frequency measured were complete.

TEST RESULTS
The initial step in collecting conducted data is a spectrum analyzer peak scan of the
measurement range. Significant peaks are then marked as shown on the following data
page, and these signals are then quasi-peaked.




FCC ID: EMJC50-6AT05                                                                                      Page 17 / 18
This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


                                                                                     Report No: C130527Z02-RP1


TEST DATA
The initial step in collecting conducted data is a spectrum analyzer peak scan of the
measurement range. Significant peaks are then marked as shown on the following data
page, and these signals are then quasi-peaked.


Operation Mode:                   Charge                         Test Date:                June 13, 2013
Temperature:                      22°C                           Tested by:                Sun Guo
Humidity:                         45% RH


            QuasiPeak Average Correction QuasiPeak Average QuasiPeak Average QuasiPeak Average
Frequency                                                                                                           Line
  (MHz)      Reading     Reading     Factor      Result      Result     Limit      Limit      Margin     Margin
                                                                                                                   (L1/L2)
              (dBuV)     (dBuV)          (dB)    (dBuV)     (dBuV)     (dBuV)      (dBuV)      (dB)       (dB)

  0.4660       21.93       9.87          9.68     31.61      19.55      56.58      46.58      -24.97     -27.03      L1

  0.5899       34.14       1.56          9.69     43.83      11.25      56.00      46.00      -12.17     -34.75      L1

  1.1900       28.64      -6.11          9.68     38.32       3.57      56.00      46.00      -17.68     -42.43      L1

  2.1180       19.60       6.33          9.68     29.28      16.01      56.00      46.00      -26.72     -29.99      L1

  4.7020       21.77       6.37          9.75     31.52      16.12      56.00      46.00      -24.48     -29.88      L1

 13.5540       25.61      -6.28          9.86     35.47       3.58      60.00      50.00      -24.53     -46.42      L1


  0.5860       27.51       6.89          9.70     37.21      16.59      56.00      46.00      -18.79     -29.41      L2

  0.6700       22.59      -8.03          9.69     32.28       1.66      56.00      46.00      -23.72     -44.34      L2

  0.9900       21.88      -3.74          9.67     31.55       5.93      56.00      46.00      -24.45     -40.07      L2

  1.2020       26.31      -9.38          9.67     35.98       0.29      56.00      46.00      -20.02     -45.71      L2

  2.3780       19.67      -11.76         9.71     29.38      -2.05      56.00      46.00      -26.62     -48.05      L2

  2.8820       19.63       1.54          9.71     29.34      11.25      56.00      46.00      -26.66     -34.75      L2
Remark:
      1. Measuring frequencies from 0.15 MHz to 30MHz.
      2. The emissions measured in frequency range from 0.15 MHz to 30MHz were made with an
         instrument using Quasi-peak detector and average detector.
      3. The IF bandwidth of SPA between 0.15MHz and 30MHz was 10kHz; the IF bandwidth of Test
         Receiver between 0.15MHz and 30MHz was 9kHz;
      4. L1 = Line One (Live Line) / L2 = Line Two (Neutral Line)




FCC ID: EMJC50-6AT05                                                                                      Page 18 / 18
This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.



Document Created: 2013-08-28 09:45:24
Document Modified: 2013-08-28 09:45:24

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC