RF Exposure Information (MPE).pdf

FCC ID: EMJ-2D712S9

RF Exposure Info

Download: PDF
FCCID_2495772

                                 RF EXPOSURE REPORT

                                       REPORT NO.:                    SA141224D03
                                         MODEL NO.:                   2D-712S9
                                                 FCC ID:              EMJ-2D712S9
                                           RECEIVED:                  Dec. 8, 2014
                                                TESTED:               Dec. 8 ~ 25, 2014
                                                 ISSUED:              Jan. 7, 2015




                    APPLICANT: PRIMAX ELECTRONICS LTD.

                       ADDRESS: No. 669, Ruey Kuang Road, Neihu, Taipei, Taiwan,
                                R.O.C.




                     ISSUED BY: Bureau Veritas Consumer Products Services (H.K.)
                                Ltd., Taoyuan Branch

            LAB LOCATION: No. 47-2, 14th Ling, Chia Pau Vil., Lin Kou Dist., New
                          Taipei City, Taiwan ( R.O.C. )




This report is for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is
permitted only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results
set forth in this report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar
or identical product unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon
the information that you provided to us. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by
our negligence, provided, however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such
issue within the prescribed time shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the
correctness of the report contents. Unless specific mention, the uncertainty of measurement has been explicitly taken into account to declare the
compliance or non-compliance to the specification.

 Report No.: SA141224D03                                                    1 of 6                                      Report Format Version 5.0.1


                                     Table of Contents
RELEASE CONTROL RECORD................................................................................. 3
1.   CERTIFICATION .............................................................................................. 4
2.   EVALUATION RESULT .................................................................................... 5
3.   SAR TEST EXCLUSION THRESHOLDS ......................................................... 6
4.   CONCLUSION ................................................................................................. 6




Report No.: SA141224D03                                 2 of 6                           Report Format Version 5.0.1


                               RELEASE CONTROL RECORD

 ISSUE NO.                REASON FOR CHANGE                  DATE ISSUED
 SA141224D03              Original release                   Jan. 7, 2015




Report No.: SA141224D03                       3 of 6    Report Format Version 5.0.1


1. CERTIFICATION

                 PRODUCT: SHARP Bluetooth 3.0 remote control
           BRAND NAME: SHARP
               MODEL NO.: 2D-712S9
               APPLICANT: PRIMAX ELECTRONICS LTD.
                    TESTED: Dec. 8 ~ 25, 2014
           TEST SAMPLE: ENGINEERING SAMPLE
             STANDARDS: FCC Part 2 (Section 2.1093)
                                   KDB 447498 D03
                                   IEEE C95.1



The above equipment has been tested by Bureau Veritas Consumer Products
Services (H.K.) Ltd., Taoyuan Branch, and found compliance with the
requirement of the above standards. The test record, data evaluation & Equipment
Under Test (EUT) configurations represented herein are true and accurate
accounts of the measurements of the sample’s EMC characteristics under the
conditions specified in this report.




  PREPARED BY             :                                           ,   DATE:    Jan. 7, 2015
                              ( Jessica Cheng / Senior Specialist )




  APPROVED BY :                                                       ,   DATE:    Jan. 7, 2015
                                ( Rex Lai / Assistant Manager )




Report No.: SA141224D03                              4 of 6                       Report Format Version 5.0.1


2. EVALUATION RESULT

Following FCC KDB 447498 D01 “General SAR test exclusion guidance”

The corresponding SAR Exclusion Threshold condition, listed below:

1) The 1-g and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test
   separation distances ≤ 50 mm are determined by:
   [(max. power of channel, including tune-up tolerance, mW)/(min. test separation
   distance, mm)] ·[√f(GHz)] ≤ 3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity SAR,16
   where
   Ø f(GHz) is the RF channel transmit frequency in GHz.
   Ø Power and distance are rounded to the nearest mW and mm before
       calculation.
   Ø The result is rounded to one decimal place for comparison The test exclusions
       are applicable only when the minimum test separation distance is ≤ 50 mm
       and for transmission frequencies between 100 MHz and 6 GHz. When the
       minimum test separation distance is < 5 mm, a distance of 5 mm is applied to
       determine SAR test exclusion.

2) At 100 MHz to 6 GHz and for test separation distances > 50 mm, the SAR test
   exclusion threshold is determined according to the following:
   a) [Threshold at 50 mm in step 1) + (test separation distance - 50mm)·( f(MHz)/150)]
      mW, at 100MHz to 1500 MHz
   b) [Threshold at 50 mm in step 1) + (test separation distance - 50 mm)·10] mW at
      > 1500 MHz and ≤ 6 GHz

3) At frequencies below 100 MHz, the following may be considered for SAR test
   exclusion.
   a) The threshold at the corresponding test separation distance at 100 MHz in step
      2) is multiplied by [1 + log(100/f(MHz))] for test separation distances > 50 mm
      and < 200 mm.
   b) The threshold determined by the equation in a) for 50 mm and 100 MHz is
      multiplied by ½ for test separation distances ≤ 50 mm.
   c) SAR measurement procedures are not established below 100 MHz. When SAR
      test exclusion cannot be applied, a KDB inquiry is required to determine SAR
      evaluation requirements for any test results to be acceptable.




Report No.: SA141224D03                   5 of 6                  Report Format Version 5.0.1


3. SAR TEST EXCLUSION THRESHOLDS

Maximum measured transmitter power:
                                       Min. test           SAR test       10-g extremity
   Frequency          Max. Power      separation           exclusion         SAR test
                                                                                              Result
     (GHz)              (mW)           distance           calculation       exclusion
                                         (mm)             value(NOTE 2)    thresholds
  2.402 ~ 2.480           1.2               5                0.372              7.5             Pass

NOTE: 1. The antenna type is Monopole printing antenna with 3.24dBi gain.
      2. Calculate SAR test exclusion thresholds from condition “1” formulas.




4. CONCLUSION

Since Source-base time average power is below SAR test exclusion power
thresholds, the SAR evaluation is not required.




Report No.: SA141224D03                          6 of 6                         Report Format Version 5.0.1



Document Created: 2019-09-27 13:24:30
Document Modified: 2019-09-27 13:24:30

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC