Revised MPE

FCC ID: ELVATRPH

RF Exposure Info

Download: PDF
FCCID_3020043

                                  RF EXPOSURE CALCULATIONS

Requirement:
According to USA CFR 15 §1.1307 (b)(1), systems operating under the provisions of this section
shall be operated in a manner that ensures the public is not exposed to radio frequency energy
level in excess of the Commission’s guidelines. For Canada, RSS-102 sets out the requirements
and measurement techniques used to evaluate radio frequency (RF) exposure compliance of
radiocommunication apparatus designed to be used within the vicinity of the human body.

Maximum Permissible Exposure Calculation:
The General Population / Uncontrolled Exposure limit for mobile devices is 1 mW/cm^2 at 20
cm separation distance for the US. For Canada, the Exposure Evaluation EIRP Limit is
computed from the formula EIRP = 1.31*10^(-2))*(f_MHz)^0.6834. Cumulative power density
at the 20 cm separation distance and total EIRP rating are computed below and compared to the
respective limits.

     USA REF: 2.1091/1093, 447498 D01 General RF Exposure Guidance v06                     Test Date:         17-Feb-16
       IC REF: RSS-102 Issue 5                                                         Test Engineer: Joseph Brunett
  Sep. Distance: >20cm                                                                          EUT: Nutek IVU – Small
                                                                                         EUT Mode:       Hopping
                                                                                      Meas. Distance:    3 meters


                                                                                         Canada                 USA
                                                                                        Worst Case
                                                      Worst Case                       Source Based
                                                     Source Based                     Time Averaged
                                                    Time Averaged Power Density         Threshold        Power Density
     Freq.          Pout* (Pk)       EIRP* (Pk)     Po/EIRP(Pk)**   S @ 20cm              (Avg)         Limit S @ 20cm
     MHz              dBm               dBm              mW         mW/cm^2                mW              mW/cm^2
     904.0            16.3              18.6             72.0         0.0143              1372.5              1.0
     914.0            16.2              18.9             77.5         0.0154            1382.9                   1.0
     923.6             16.2            18.8            75.9           0.0151            1392.8                   1.0
*As Measured / Computed from highest fundamental emission, see fundamental emission section of this report.
**Only RMS level is required, RMS/6min << Pk, Peak emission employed to demonstrate compliance.


Summary:
The EUT with both transmitters is compliant with both the FCC power density limit and the IC
Exposure Evaluation EIRP limit.