RF Exposure

FCC ID: ELVATRPH

RF Exposure Info

Download: PDF
FCCID_2979460

                RF Exposure / SAR / Health Hazard Statement
Requirement:
According to USA CFR 15 §1.1307 (b)(1), systems operating under the provisions of this section shall be
operated in a manner that ensures the public is not exposed to radio frequency energy level in excess of
the Commission’s guideline. For Canada, RSS-102 Tests out the requirements and measurement
techniques used to evaluate radio frequency (RF) exposure compliance of radiocommunication apparatus
designed to be used within the vicinity of the human body.

SAR Testing Exclusion:
Per FCC 447498 General RF Exposure Guidance v05, Section 4.3.1, the 1-g (body) and 10-g (extremity)
SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation distances ≤ 50 mm are determined
by the following formula
                                                  PC
                                           SAR=
                                                  d
                                                     √ f GHz
where d = minimum test distance and Pc is the source-based time-averaged maximum conducted output
power, or EIRP for a device without a removable antenna.

For IC RSS-102, the SAR threshold is based on the higher of conducted output power and EIRP and is
based on a power rating set for 1-g and 10-g SAR.

Exposure Duty Cycle:
The maximum power duty cycle was measured to be 2.058% as detailed in the EUT test report.

Thus, power (exposure) duty cycle is computed to be:

                         Power Duty Cycle = 10*Log10(0.02058) = -16.9 dB

This duty cycle is the worst case SOURCE-BASED TIME-AVERAGED duty cycle for this product.

Power Rating:
The chipset manufacturer's most recent datasheet states a maximum power rating for the chipset of 20
dBm, however the transmit power avaliable at the antenna report is 16.7 dBm after filter network and RF
switch insertion losses. The worst case measured antenna gain for the EUT is 3.1 dBi, implying that the
measured EIRP (19.9 dBm) is equivalent to the chipset power rating (20 dBm). EIRP is used in
computing health hazard below. Average power rating is computed from the peak value and the power
duty cycle detailed above.


  SAR Threshold:
  The SAR threshold at a minimum test distance of <5 mm are thus computed to be:


                                                                                                                   Test Date:    17-Feb-16
              USA REF: 2.1091/1093, 447498 D01 General RF Exposure Guidance v06                                Test Engineer: Joseph Brunett
                IC REF: RSS-102 Issue 5                                                                                 EUT: Nutek IVU – Large
      Min. Sep. Distance: <5mm                                                                                   EUT Mode:        Hopping
                                                                                                              Meas. Distance:     3 meters


                                                                Canada                                       USA
                                                          1-g SAR Body     10-g SAR                 1-g SAR Body     10-g SAR
                                               Calculated     Power      Extremity Power Calculated     Power      Extremity Power
                                                  SAR       Threshold       Threshold       SAR       Threshold       Threshold
         Pout* EIRP*** Exposure    Worst Case  Threshold Exclusion Limit Exclusion Limit Threshold Exclusion Limit Exclusion Limit
 Freq.    Pk      Pk     Duty   Po/EIRP(Avg)**   (Avg)        (Avg)           (Avg)        (Avg)        (Avg)           (Avg)
 MHz     dBm     dBm      dB     dBm      mW      mW           mW              mW
 904.0   16.7    19.9    16.9     3.0     2.0      2.0         16.4            40.9          .4          3.0             7.5
 914.0   16.5    19.4    16.9     2.5     1.8      1.8         16.3            40.6          .3          3.0             7.5
 923.6   16.2    19.3    16.9     2.4     1.8      1.8         16.2            40.4          .3          3.0             7.5

*As Measured / Computed from highest fundamental emission, see fundamental emission section of this report.
**Only RMS level is required, RMS/6min << Pk, Peak emission employed to demonstrate compliance.




  Thus the EUT meets the test exclusion thresholds for 1-g and 10-g SAR evaluation.