SAR Report 3

FCC ID: EHTDECT1

RF Exposure Info

Download: PDF
FCCID_808601

                                                               DAT-P-152/98-01




                                                                                              Appendix for the Report
                                                                                  Dosimetric Assessment of the
                                                                                       Mitel Cordless Handset
                                                                                          (FCC ID: EHTDECT1)

                                                                       According to the FCC Requirements

                                                                                                 SAR Distribution Plots


                                                                                                                      May 21, 2007
                                                                                                                       IMST GmbH
                                                                                                         Carl-Friedrich-Gauß-Str. 2
                                                                                                              D-47475 Kamp-Lintfort
dasy_report_fcc_DECT_1900_plots_1.0.doc/110.05.2006/ABo




                                                                                                                               Customer
                                                                                                                              Nemko AS
                                                                                                                           Gasevikveien 8
                                                                                                                           N-22027 Kjeller


                                                                                                The test results only relate to the items tested.
                                                                          This report shall not be reproduced except in full without the written
                                                                                                             approval of the testing laboratory.
                                                          SAR Report_Nemko_6620_636_FCC_DECT_SAR Plots_Mitel_Handset               Page 1 of 11


                                                          SAR Report_Nemko_6620_636_FCC_DECT_SAR Plots_Mitel_Handset                                                              Page 2 of 11

                                                          Table of Contents

                                                          1   SAR DISTRIBUTION PLOTS, HEAD MEASUREMENTS, ANTENNA 1................................................ 3

                                                          2   SAR DISTRIBUTION PLOTS, HEAD MEASUREMENTS, ANTENNA 2................................................ 7

                                                          3   SAR Z-AXIS SCANS (VALIDATION) ......................................................................................................... 11

                                                          4   SAR Z-AXIS SCANS (MEASUREMENTS)................................................................................................ 11
dasy_report_fcc_DECT_1900_plots_1.0.doc/110.05.2006/ABo


                                                          SAR Report_Nemko_6620_636_FCC_DECT_SAR Plots_Mitel_Handset                            Page 3 of 11

                                                          1 SAR Distribution Plots, Head Measurements, Antenna 1

                                                          Test Laboratory: Imst GmbH, DASY Yellow (II); File Name: 5330_handset_yplm_1_Ant1.da4

                                                          DUT: MITEL; Type: Corless Handset
                                                          Program Name: Cheek Left

                                                          Communication System: DECT US; Frequency: 1924.99 MHz;Duty Cycle: 1:12
                                                          Medium parameters used (extrapolated): f = 1924.99 MHz; σ = 1.42 mho/m; εr = 40.4; ρ = 1000 kg/m3
                                                          Phantom section: Left Section

                                                          DASY4 Configuration:
                                                          - Probe: EX3DV4 - SN3536; ConvF(8.19, 8.19, 8.19); Calibrated: 27.09.2006
                                                          - Sensor-Surface: 4mm (Mechanical Surface Detection)
                                                          - Electronics: DAE4 Sn631; Calibrated: 11.07.2006
                                                          - Phantom: SAM Glycol 1340; Type: QD 000 P40 CB; Serial: TP-1340
                                                          - Measurement SW: DASY4, V4.7 Build 53; Postprocessing SW: SEMCAD, V1.8 Build 172

                                                          Cheek Left/Area Scan (8x17x1): Measurement grid: dx=15mm, dy=15mm
                                                          Maximum value of SAR (measured) = 0.001 mW/g
                                                          Cheek Left/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm
                                                          Peak SAR (extrapolated) = 0.000 W/kg
                                                          SAR(1 g) = n.a. ; SAR(10 g) = n.a.
dasy_report_fcc_DECT_1900_plots_1.0.doc/110.05.2006/ABo




                                                          Fig. 1: SAR distribution for DECT US, channel 2, cheek position, left side of head
                                                                  (May 15, 2007; Ambient Temperature: 21.9°C; Liquid Temperature: 21.0°C).


                                                          SAR Report_Nemko_6620_636_FCC_DECT_SAR Plots_Mitel_Handset                            Page 4 of 11

                                                          Test Laboratory: Imst GmbH, DASY Yellow (II); File Name: 5330_handset_yplm_2_Ant1.da4

                                                          DUT: MITEL; Type: Corless Handset
                                                          Program Name: Tilted Left

                                                          Communication System: DECT US; Frequency: 1924.99 MHz;Duty Cycle: 1:12
                                                          Medium parameters used (extrapolated): f = 1924.99 MHz; σ = 1.42 mho/m; εr = 40.4; ρ = 1000 kg/m3
                                                          Phantom section: Left Section

                                                          DASY4 Configuration:
                                                          - Probe: EX3DV4 - SN3536; ConvF(8.19, 8.19, 8.19); Calibrated: 27.09.2006
                                                          - Sensor-Surface: 4mm (Mechanical Surface Detection)
                                                          - Electronics: DAE4 Sn631; Calibrated: 11.07.2006
                                                          - Phantom: SAM Glycol 1340; Type: QD 000 P40 CB; Serial: TP-1340
                                                          - Measurement SW: DASY4, V4.7 Build 53; Postprocessing SW: SEMCAD, V1.8 Build 172

                                                          Tilted Left/Area Scan (8x17x1): Measurement grid: dx=15mm, dy=15mm
                                                          Maximum value of SAR (measured) = 0.001 mW/g
                                                          Tilted Left/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm
                                                          Peak SAR (extrapolated) = 0.002 W/kg
                                                          SAR(1 g) = n.a. ; SAR(10 g) = n.a.
dasy_report_fcc_DECT_1900_plots_1.0.doc/110.05.2006/ABo




                                                          Fig. 2: SAR distribution for DECT US, channel 2, tilted position, left side of head
                                                                  (May 15, 2007; Ambient Temperature: 21.9°C; Liquid Temperature: 21.0°C).


                                                          SAR Report_Nemko_6620_636_FCC_DECT_SAR Plots_Mitel_Handset                            Page 5 of 11

                                                          Test Laboratory: Imst GmbH, DASY Yellow (II); File Name: 5330_handset_yprm_1_Ant1.da4

                                                          DUT: MITEL; Type: Corless Handset
                                                          Program Name: Cheek Right

                                                          Communication System: DECT US; Frequency: 1924.99 MHz;Duty Cycle: 1:12
                                                          Medium parameters used (extrapolated): f = 1924.99 MHz; σ = 1.42 mho/m; εr = 40.4; ρ = 1000 kg/m3
                                                          Phantom section: Right Section

                                                          DASY4 Configuration:
                                                          - Probe: EX3DV4 - SN3536; ConvF(8.19, 8.19, 8.19); Calibrated: 27.09.2006
                                                          - Sensor-Surface: 4mm (Mechanical Surface Detection)
                                                          - Electronics: DAE4 Sn631; Calibrated: 11.07.2006
                                                          - Phantom: SAM Glycol 1340; Type: QD 000 P40 CB; Serial: TP-1340
                                                          - Measurement SW: DASY4, V4.7 Build 53; Postprocessing SW: SEMCAD, V1.8 Build 172

                                                          Cheek Right/Area Scan (8x17x1): Measurement grid: dx=15mm, dy=15mm
                                                          Maximum value of SAR (measured) = 0.001 mW/g
                                                          Cheek Right/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm
                                                          Peak SAR (extrapolated) = 0.000 W/kg
                                                          SAR(1 g) = n.a. ; SAR(10 g) = n.a.
dasy_report_fcc_DECT_1900_plots_1.0.doc/110.05.2006/ABo




                                                          Fig. 3:   SAR distribution for DECT US, channel 2, cheek position, right side of head
                                                                    (May 15, 2007; Ambient Temperature: 21.9°C; Liquid Temperature: 21.0°C).


                                                          SAR Report_Nemko_6620_636_FCC_DECT_SAR Plots_Mitel_Handset                            Page 6 of 11

                                                          Test Laboratory: Imst GmbH, DASY Yellow (II); File Name: 5330_handset_yprm_2_Ant1.da4

                                                          DUT: MITEL; Type: Corless Handset
                                                          Program Name: Tilted Right

                                                          Communication System: DECT US; Frequency: 1924.99 MHz;Duty Cycle: 1:12
                                                          Medium parameters used (extrapolated): f = 1924.99 MHz; σ = 1.42 mho/m; εr = 40.4; ρ = 1000 kg/m3
                                                          Phantom section: Right Section

                                                          DASY4 Configuration:
                                                          - Probe: EX3DV4 - SN3536; ConvF(8.19, 8.19, 8.19); Calibrated: 27.09.2006
                                                          - Sensor-Surface: 4mm (Mechanical Surface Detection)
                                                          - Electronics: DAE4 Sn631; Calibrated: 11.07.2006
                                                          - Phantom: SAM Glycol 1340; Type: QD 000 P40 CB; Serial: TP-1340
                                                          - Measurement SW: DASY4, V4.7 Build 53; Postprocessing SW: SEMCAD, V1.8 Build 172

                                                          Tilted Right/Area Scan (8x17x1): Measurement grid: dx=15mm, dy=15mm
                                                          Maximum value of SAR (measured) = 0.001 mW/g
                                                          Tilted Right/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm
                                                          Peak SAR (extrapolated) = 0.002 W/kg
                                                          SAR(1 g) = n.a. ; SAR(10 g) = n.a.
dasy_report_fcc_DECT_1900_plots_1.0.doc/110.05.2006/ABo




                                                          Fig. 4:   SAR distribution for DECT US, channel 2, tilted position, right side of head
                                                                    (May 15, 2007; Ambient Temperature: 21.9°C; Liquid Temperature: 21.0°C)


                                                          SAR Report_Nemko_6620_636_FCC_DECT_SAR Plots_Mitel_Handset                            Page 7 of 11

                                                          2 SAR Distribution Plots, Head Measurements, Antenna 2

                                                          Test Laboratory: Imst GmbH, DASY Yellow (II); File Name: 5330_handset_yplm_1_Ant2.da4

                                                          DUT: MITEL; Type: Corless Handset
                                                          Program Name: Cheek Left

                                                          Communication System: DECT US; Frequency: 1924.99 MHz;Duty Cycle: 1:12
                                                          Medium parameters used (extrapolated): f = 1924.99 MHz; σ = 1.42 mho/m; εr = 40.4; ρ = 1000 kg/m3
                                                          Phantom section: Left Section

                                                          DASY4 Configuration:
                                                          - Probe: EX3DV4 - SN3536; ConvF(8.19, 8.19, 8.19); Calibrated: 27.09.2006
                                                          - Sensor-Surface: 4mm (Mechanical Surface Detection)
                                                          - Electronics: DAE4 Sn631; Calibrated: 11.07.2006
                                                          - Phantom: SAM Glycol 1340; Type: QD 000 P40 CB; Serial: TP-1340
                                                          - Measurement SW: DASY4, V4.7 Build 53; Postprocessing SW: SEMCAD, V1.8 Build 172

                                                          Cheek Left/Area Scan (8x17x1): Measurement grid: dx=15mm, dy=15mm
                                                          Maximum value of SAR (measured) = 0.001 mW/g
                                                          Cheek Left/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm
                                                          Peak SAR (extrapolated) = 0.002 W/kg
                                                          SAR(1 g) = n.a. ; SAR(10 g) = n.a.
dasy_report_fcc_DECT_1900_plots_1.0.doc/110.05.2006/ABo




                                                          Fig. 5: SAR distribution for DECT US, channel 2, cheek position, left side of head
                                                                  (May 15, 2007; Ambient Temperature: 21.9°C; Liquid Temperature: 21.0°C).


                                                          SAR Report_Nemko_6620_636_FCC_DECT_SAR Plots_Mitel_Handset                            Page 8 of 11

                                                          Test Laboratory: Imst GmbH, DASY Yellow (II); File Name: 5330_handset_yplm_2_Ant2.da4

                                                          DUT: MITEL; Type: Corless Handset
                                                          Program Name: Tilted Left

                                                          Communication System: DECT US; Frequency: 1924.99 MHz;Duty Cycle: 1:12
                                                          Medium parameters used (extrapolated): f = 1924.99 MHz; σ = 1.42 mho/m; εr = 40.4; ρ = 1000 kg/m3
                                                          Phantom section: Left Section

                                                          DASY4 Configuration:
                                                          - Probe: EX3DV4 - SN3536; ConvF(8.19, 8.19, 8.19); Calibrated: 27.09.2006
                                                          - Sensor-Surface: 4mm (Mechanical Surface Detection)
                                                          - Electronics: DAE4 Sn631; Calibrated: 11.07.2006
                                                          - Phantom: SAM Glycol 1340; Type: QD 000 P40 CB; Serial: TP-1340
                                                          - Measurement SW: DASY4, V4.7 Build 53; Postprocessing SW: SEMCAD, V1.8 Build 172

                                                          Tilted Left/Area Scan (8x17x1): Measurement grid: dx=15mm, dy=15mm
                                                          Maximum value of SAR (measured) = 0.002 mW/g
                                                          Tilted Left/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm
                                                          Peak SAR (extrapolated) = 0.051 W/kg
                                                          SAR(1 g) = n.a. ; SAR(10 g) = n.a.
                                                          Maximum value of SAR (measured) = 0.001 mW/g
dasy_report_fcc_DECT_1900_plots_1.0.doc/110.05.2006/ABo




                                                          Fig. 6: SAR distribution for DECT US, channel 2, tilted position, left side of head
                                                                  (May 15, 2007; Ambient Temperature: 21.9°C; Liquid Temperature: 21.0°C).


                                                          SAR Report_Nemko_6620_636_FCC_DECT_SAR Plots_Mitel_Handset                            Page 9 of 11

                                                          Test Laboratory: Imst GmbH, DASY Yellow (II); File Name: 5330_handset_yprm_1_Ant2.da4

                                                          DUT: MITEL; Type: Corless Handset
                                                          Program Name: Cheek Right

                                                          Communication System: DECT US; Frequency: 1924.99 MHz;Duty Cycle: 1:12
                                                          Medium parameters used (extrapolated): f = 1924.99 MHz; σ = 1.42 mho/m; εr = 40.4; ρ = 1000 kg/m3
                                                          Phantom section: Right Section

                                                          DASY4 Configuration:
                                                          - Probe: EX3DV4 - SN3536; ConvF(8.19, 8.19, 8.19); Calibrated: 27.09.2006
                                                          - Sensor-Surface: 4mm (Mechanical Surface Detection)
                                                          - Electronics: DAE4 Sn631; Calibrated: 11.07.2006
                                                          - Phantom: SAM Glycol 1340; Type: QD 000 P40 CB; Serial: TP-1340
                                                          - Measurement SW: DASY4, V4.7 Build 53; Postprocessing SW: SEMCAD, V1.8 Build 172

                                                          Cheek Right/Area Scan (8x17x1): Measurement grid: dx=15mm, dy=15mm
                                                          Maximum value of SAR (measured) = 0.001 mW/g
                                                          Cheek Right/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm
                                                          Peak SAR (extrapolated) = 0.001 W/kg
                                                          SAR(1 g) = n.a. ; SAR(10 g) = n.a.
dasy_report_fcc_DECT_1900_plots_1.0.doc/110.05.2006/ABo




                                                          Fig. 7:   SAR distribution for DECT US, channel 2, cheek position, right side of head
                                                                    (May 15, 2007; Ambient Temperature: 21.9°C; Liquid Temperature: 21.0°C).


                                                          SAR Report_Nemko_6620_636_FCC_DECT_SAR Plots_Mitel_Handset Page 10 of 11

                                                          Test Laboratory: Imst GmbH, DASY Yellow (II); File Name: 5330_handset_yprm_2_Ant2.da4

                                                          DUT: MITEL; Type: Corless Handset
                                                          Program Name: Tilted Right

                                                          Communication System: DECT US; Frequency: 1924.99 MHz;Duty Cycle: 1:12
                                                          Medium parameters used (extrapolated): f = 1924.99 MHz; σ = 1.42 mho/m; εr = 40.4; ρ = 1000 kg/m3
                                                          Phantom section: Right Section

                                                          DASY4 Configuration:
                                                          - Probe: EX3DV4 - SN3536; ConvF(8.19, 8.19, 8.19); Calibrated: 27.09.2006
                                                          - Sensor-Surface: 4mm (Mechanical Surface Detection)
                                                          - Electronics: DAE4 Sn631; Calibrated: 11.07.2006
                                                          - Phantom: SAM Glycol 1340; Type: QD 000 P40 CB; Serial: TP-1340
                                                          - Measurement SW: DASY4, V4.7 Build 53; Postprocessing SW: SEMCAD, V1.8 Build 172

                                                          Tilted Right/Area Scan (8x17x1): Measurement grid: dx=15mm, dy=15mm
                                                          Maximum value of SAR (measured) = 0.001 mW/g
                                                          Tilted Right/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm
                                                          Peak SAR (extrapolated) = 0.001 W/kg
                                                          SAR(1 g) = n.a. ; SAR(10 g) = n.a.
dasy_report_fcc_DECT_1900_plots_1.0.doc/110.05.2006/ABo




                                                          Fig. 8:   SAR distribution for DECT US, channel 2, tilted position, right side of head
                                                                    (May 15, 2007; Ambient Temperature: 21.9°C; Liquid Temperature: 21.0°C)


                                                          SAR Report_Nemko_6620_636_FCC_DECT_SAR Plots_Mitel_Handset Page 11 of 11

                                                          3 SAR z-axis scans (Validation)




                                                          Fig. 9:   SAR versus liquid depth, 1900 MHz, head (May 15, 2007; Ambient
                                                                    Temperature: 21.8° C; Liquid Temperature : 21.0° C).




                                                          4 SAR z-axis scans (Measurements)

                                                          Due to the not detectable values, plots were not listed
dasy_report_fcc_DECT_1900_plots_1.0.doc/110.05.2006/ABo



Document Created: 2007-05-22 11:35:38
Document Modified: 2007-05-22 11:35:38

© 2024 FCC.report