Manual

FCC ID: E9USDC1000

Users Manual

Download: PDF
FCCID_136101

                                         MOTOROLA
SDC1000                SINGLE DOOR ACCESS CONTROLLER




          OPERATING MANUAL

          MOTOROLA SDC1000




                 -1-


                                                        MOTOROLA
SDC1000                               SINGLE DOOR ACCESS CONTROLLER




                       CONTENTS

           1. Important Safety Instructions
           2. General
           3. Features
           4. Specifications
           5. Name of the Parts
           6. Identifying supplied parts
           7. Installation of the Product
           8. Wire Color Table of the Main Unit
           9. Wire Connection in of basic application
          10. Initial Setup
          11. Operation
          12. Setting Changes
          13. FCC REGISTRATION INFORMATION
          14. Warranty and Service




                               -2-


                                                                                                         MOTOROLA
SDC1000                                                                   SINGLE DOOR ACCESS CONTROLLER

1. Important Safety Instructions
When using your door access controller, basing safety precautions should always be followed to reduce the risk of fire,
electrical shock, and injury to persons including following:
1. Read and understand all instructions.
2. Follow all warnings and instructions marked on the product
3. Do not use liquid cleaners, or aerosol cleaners. Use a damp cloth for cleaning. if necessary, use a mild soap.
4. Do not use this product near water, for example near a bath tub, wash bowl, kitchen sink, or laundry tub, in a wet
basement, or near a swimming pool.
5. This product should be operated only from the type of power source indicated on the marking label. if you are not sure of
the type of power supply to your home, consult your dealer or local power company.
6. Never push objects of any kind into this product though the cabinet slots as they may touch voltage points or short out
parts that could result in a risk of fire or electric shock. Never spill liquid of any kind on the product.
7. To reduce the risk of electric shock, do not disassemble this product, but take it to a qualified serviceman when some
service or repair work is required. Opening or removing covers may expose you to dangerous voltages or other risks.
incorrect reassembly can cause electric shock when the appliance is subsequently used.
8. Unplug this product from the wall outlet and refer to qualified service personnel under the following conditions:
   a. When the power supply cord or plug is damaged or frayed.
   b. If liquid has been spilled into the product
   c. If the product has exposed to rain or water.
   d. If the product doses not operate normally by following the operating instructions.
      Adjust only those controls, that are covered by the operating instructions. Improper
      adjustment of other controls in damage and will often require extensive work by a qualified
      technician to restore the to normal operation.
   e. If the product exhibit a distinct change in performance.

2. General
SDC1000 is an intelligent one door Access Controller based on powerful 8 bit Microprocessor to meet a simple and
cost-effective access control market requirement. User friendly device allows you to register max. 128 USER IDs and easy
to add or delete USER RFIDs.
There are 5 inputs to connect EXIT Button, door contact, PIR sensor , Fire sensor and extra and you can program related
output sources and activate timing from the front keypads. System will make alarm in case of number of times wrong entry
and Temper switch opens and one TTL output can be connected to Auto-dialer (option) will make a call to the pre-defined
phone numbers (max 4ch) and report the alarm to Police, Fire station and/or to your cellular phone by voice message. All
event transaction report to the computer by RS232C communication.
The modern design and easy installation will provide you an accurate access control for single door and 3 LED indicators
informs you all system operating at real time. SDC1000 will give you field proven reliability and cost-effective solution
anywhere the access controls and high security is required.

3. Features
- One door Access Controller
- Powerful dual 8 bit Microprocessors
- Built-in 4” Proximity Reader
- 128 USER Access RFIDs including one Master RFID
- Independant 5 inputs and 4 outputs including 2 output Relays
- All I/Os and activating Times user front programmable
- Door Lock and Unlock function
- Setting for Safe/Secure mode
- Numbers of Try-out error Alarm
- RS232 communication port for remote control and events report
- 3 LEDs for system operation status
- Modern design and easy operation




                                                           -3-


                                                                                 MOTOROLA
SDC1000                                                        SINGLE DOOR ACCESS CONTROLLER

4. Specification
       .CPU                     : Dual 8 bit Microprocessors
       .Memory                  : 8 KB Program memory
                                  512 bytes Flash memory
       .User PIN numbers        : 128 User RFIDs including one Master RFID
       .Proximity Reader        : Built-in 4” Proximity reader
       .Input/Output            : 5 Inputs max. rating at DC 12V/20mA
                                : 2 Relay outputs : DC12V/2A
                                : 1 chime bell output : 5V/150mA ,
                                : 1 TTL output : 5V/20mA
       .Communication           : One RS232C port, 9600 Baud Rate,N,8,1
       .Keypads                 : 12 Numeric Keypads
       .LED                     : 3 LEDs(RED, GREEN, YELLOW)
       .Power                   : DC 12V/ 200mA
       .Operating Environment   : 0°C to +60°C, 10% to 90% Humidity
       .Reset                   : Power ON Reset



5. Name of each part
            SDC1000
            Main Unit




6. Identifying supplied parts
Please unpack and check the contents of the box.




  Main Unit      Wall Mount      O-Ring       Instructions
   (1 EA)         (1 EA)        (5 EA)         (1 EA)




                                                  -4-


                                                                                          MOTOROLA
SDC1000                                                         SINGLE DOOR ACCESS CONTROLLER

7. Installation of the Product
 7-1. Drill two 6-32 holes and one 1/2" hole on the proper location of the wall.
      (If the gang box is already installed on the wall then skip this step.)
 7-2. Using 2 screws, install wall mount to the wall.
 7-3. Insert 5 O-rings to the wall mount as indicated, then route the cable of the main
      unit through the center hole and push the main unit to wall mount to lock the main
      unit and make sure that the main unit is locked with wall mount.




* CAUTIONS *
When the main unit is once fixed to wall mount, the locking pins will tighten the main unit
therefore the operation test of the main unit should be required prior to fix the main unit to
wall mount. If the main unit has to be disassembled from the wall mount, then you need another
wall mount to be replaced as the locking pins of wall mount will be broken when the main unit
detached from the wall mount.




                                                    -5-


                                                                        MOTOROLA
SDC1000                                    SINGLE DOOR ACCESS CONTROLLER

8. Wire Color Table of the Main Unit

POWER
Power(DC 12V)         +12V              Red wire, Red with White stripe
Power(DC 12V)         0V(GND)           Black wire, Black with White stripe

OUTPUT
Door RELAY(2A)        COM               Gray wire with Red stripe
Door RELAY(2A)        NC                Blue wire with White stripe
Door RELAY(2A)        NO                White wire with Red stripe

Alarm RELAY(2A)       COM               White wire
Alarm RELAY(2A)       NC                Purple wire with White stripe
Alarm RELAY(2A)       NO                Purple wire

TTL Output            TTL               Orange wire with White stripe
CHIME BELL Output     BELL              Brown wire with White stripe

INPUT
Exit Button           EXIT              Yellow wire with Red stripe
Door Sensor           CONTACT           Green wire
External Input #1     IN#1              Orange wire
External Input #2     IN#2              Green wire with White stripe
External Input #3     IN#3              Brown wire
Extra Reader Input    DATA0             Pink wire
Extra Reader Input    DATA1             Cyan wire

RS232C INTERFACE
RS232-TX              TXD               Grey wire
RS232-RX              RXD               Blue wire
RS232-GND             GND               Yellow wire




                                  -6-


                                                                          MOTOROLA
SDC1000                                                 SINGLE DOOR ACCESS CONTROLLER

9. Wire connection for basic application
  This connection can be changed for different applications.




                                             -7-


                                                                                     MOTOROLA
SDC1000                                                    SINGLE DOOR ACCESS CONTROLLER
9-1. Power Connection
    Connect (+)wire of DC 12V power to Red wire and Red/White stripe wire and
    connect Power GND(-)wire of DC 12V to Black wire and Black/White stripe wire.

9-2. Door Lock connection
 9-2-1 Connection of POWER FAIL SAFE: Door Lock
       - Connect Door RELAY(COM),Grey/Red stripe wire to DC +12V.
       - Connect (+)wire of Door Lock to Door RELAY(NC),Blue/White stripe wire.
       - Connect (-)wire of Door Lock to Power GND(-) wire.
 9-2-2 Connection of POWER FAIL SECURE Door Lock
       - Connect Door RELAY(COM),Grey/Red stripe wire to DC +12V.
       - Connect (+)wire of Door Lock to Door RELAY(NO),White/Red stripe wire.
       - Connect (-)wire of Door Lock to Power GND(-) wire.

9-3. Alarm Device connection
  - Connect Alarm RELAY(COM),white wire to DC +12V.
  - Connect (+)wire of Alarm Device to Alarm RELAY(NO),Purple wire.
  - Connect (-)wire of Alarm Device to Power GND(-) wire.

9-4. Exit Button connection
  - Connect one of the wire of Exit Button to Exit Button Input, Yellow/Red stripe wire.
  - Connect the other wire of Exit Button to Power GND(-) wire.
     (In case of using Normal Closing Contact for Exit Button then please make setting
      change of ACTIVE level of Exit Button in section 8-20)

9-5. Door Contact sensor connection
  - Connect Door Contact sensor(COM) wire to Door Contact Input, Green wire.
  - Connect Door Contact sensor(NO) wire to Power GND(-) wire.
     (In case of using Normal Closing(NC) Contact for Door Contact sensor then
      please make setting change of ACTIVE level of Door Contact in section 8-21)

9-6. Auxiliary Input Device connection(Applied to AUX Input#1,#2,#3)
  - Connect one wire of Auxiliary Input Device to AUX Input wire
     (Input#1 Orange, Input#2 Green/White stripe, Input#3 Brown wire).
  - Connect the other wire of Auxiliary Input Device to Power GND(-) wire.
     (In case of using Normal Closing(NC) Contact for Auxiliary Input Device then
      please make setting change of ACTIVE level of AUX Input in section 8-17 ~ 8-19)



                                               -8-


                                                                                      MOTOROLA
SDC1000                                                      SINGLE DOOR ACCESS CONTROLLER
 9-7. Auto-dialer connection(Extra Purchase, If Necessary)
   - Connect the input wire of Auto-dialer to TTL output, Orange/White stripe wire.
   - Connect (+)wire of Auto-dialer to DC +12V.
   - Connect (-)wire of Auto-dialer to Power GND(-) wire.
   - Connect Telephone Line plug(RJ-14) to Auto-dialer.
      (In case of using Low ACTIVE for Auto-dialer then
       please make setting change of ACTIVE level of TTL Output in section 8-22)

 9-8. RS232C Communication port Connection
   9-pin connector(COM Port, female) is required to connect Serial communication
   (RS232C) between Main Unit to Personal Computer.
   Purchase 9-pin Female Connector, then connect wires as follow.
   - Connect RS232-TX, Grey wire of Main Unit to pin number 2 of 9-pin connector.
   - Connect RS232-RX, Blue wire of Main Unit to pin number 3 of 9-pin connector.
   - Connect RS232-GND, Yellow wire of Main Unit to pin number 5 of 9-pin connector.
   - Plug in 9-pin connector to COM1 or COM2 Port of Personal Computer.
   - Install and run SDC1000 Time & Attendance Software.

 9-9. Chime Bell Unit connection(Extra Purchase, If Necessary)
   - Connect Red(+) wire of Chime Bell Unit to Bell Output, Brown/White wire of Main Unit.
   - Connect Black(-) wire of Chime Bell Unit to Power GND(-) wire.

9-10. Extra Proximity Reader connection(Extra Purchase, If Necessary)
    - Connect (+)wire of Reader to DC +12V.
   - Connect (-)wire of Reader to Power GND(-) wire.
   - Connect Wiegand output DATA0 of Reader to Pink wire
   - Connect Wiegand output DATA1 of Reader to Cyan wire.




                                                -9-


                                                                                             MOTOROLA
SDC1000                                                          SINGLE DOOR ACCESS CONTROLLER

10. Initial Setup
Main Unit has Flash Memory to retain all setting values and when it delivered to customer there is no
data in the memory therefore Initial Setup is required for the first use.
 10-1. Registration of RF Cards for RF CARD ONLY MODE
  * This mode is only applicable when the extra proximity reader is connected.
    ¨ çTurn switch on DC12V Power Supply.
       All 3 LEDs will be flashing with starting sound.
   ¨ èPress 0 1 ENT from the keypad.(RF CARD ONLY MODE )

   ¨ éPresent RF Cards as follow to register Master Card and User Access Cards.



                                                     ........
       Master Card         User Access Cards                     Master Card(Finish setup)

   ¨ êFirst read card is registered as Master Card and the RF Cards followed to Master
      Card are registered as User Access Cards then present Master Card again to finish
      setup. (Please keep Master Card at the secure location for further setting changes.)
   ¨ ëNow, the Main Unit is entered to normal operation mode with default setting.

 10-2. Registration of RF Cards with PIN for RF CARD + PIN MODE
  * This mode is only applicable when the extra proximity reader is connected.
  ¨ çTurn switch on DC12V Power Supply.
      All 3 LEDs will be flashing with starting sound.
   ¨ èPress 0 2 ENT from the keypad.(RF CARD + PIN MODE )
   ¨ éPresent RF Cards as follow to register Master Card and User Access Cards and type
       4~6 digits Personal Identification Number(PIN) followed by each User Access Card.



                                                   ........
       Master Card      User Access Cards+PINENT                Master Card(Finish setup)

   ¨ êFirst read card is registered as Master Card and the RF Cards+PINENT followed
       to Master Card are registered as User Access Cards with PIN numbers then present
       Master Card again to finish setup.
       (Please keep Master Card at the secure location for further setting changes.)


                                                 - 10 -


                                                                                         MOTOROLA
SDC1000                                                        SINGLE DOOR ACCESS CONTROLLER
  ¨ ëNow, the Main Unit is entered to normal operation mode with default setting.

10-3. Registration of PIN ONLY MODE
  ¨ çTurn switch on DC12V Power Supply.
     All 3 LEDs will be flashing with starting sound.
  ¨ èPress 0 3 ENT from the keypad.(PIN ONLY MODE )
  ¨ éEnter a 8 digits PIN number + ENT to register Master PIN number then type 4~6
     digits PIN number + ENT to register User Access PIN numbers then type 8 digits
     Master PIN number to finish setup.

      8digits PINENT         4~6digits PINENT ...             8digits Master PINENT
        Master PIN           User Access PIN ...              Master PIN(Finish setup)

  ¨ êFirst 8 digits PIN number is registered as Master PIN and 4~6 digits PIN followed
      to Master PIN are registered as User Access PIN numbers then type Master PIN
      again to finish setup.
      (Please write and remember Master PIN number for further setting changes.)
  ¨ ëNow, the Main Unit is entered to normal operation mode with default setting.


10-4. Default Setting Values
After the Initial Setup, the Main Unit stores its default setting values as follows and run
normal operation mode. If you want to change the setting values, add or delete USER
Access Cards(or PIN) then please refer to "Setting Changes" in section 8.
  ¨ çWhen User Access Card(or PIN) is granted
   - Door RELAY activates for 3sec.
   - Green LED lights on for 3sec.


  ¨ èWhen User Access Card(or PIN) is denied
   - Alarm RELAY activates for 2sec.
   - Red LED lights on for 2sec.




                                                  - 11 -


                                                                                      MOTOROLA
SDC1000                                                             SINGLE DOOR ACCESS CONTROLLER

11. Operation
11-1. Normal Operation Mode(Safe Mode)
                   When the Main Unit is running in normal operation mode,
                   Yellow LED is flashing every second.


11-2. Open the Door
                          User Access Card(or PIN) is granted, Door opens for 3 seconds
                                                           with "do-mi-sol-do" melody.

     Registered card(or PIN)


11-3. Exit(Open the Door)
                      To exit, press Exit Button and Door opens for 3 seconds.




11-4. Alarm by Unregistered Card(or PIN)
    User Access Card(or PIN) is not registered and access is denied,
    then Alarm RELAY activates for 2 sec. with "sol-do-sol-do" melody.




   Unregistered card(or PIN)
    (If you do not want to activate Alarm, then please change settings in section 8-22.)
11-5. Secure Mode
   Last exit person can change the mode from Safe Mode to Secure Mode by pressing.
    Secure Code from the keypad so that the Alarm will generate by AUX Inputs.
                          -> Change to Secure Mode.

    It will canceled automatically when the registered card(or PIN) is present.
11-6. DURESS Alarm
    In case of opening the door by Duress condition, press Duress PassWordENT and
    open the door as usual then Duress Alarm(TTL Output) will activate.




                                                      - 12 -


                                                                                    MOTOROLA
SDC1000                                                    SINGLE DOOR ACCESS CONTROLLER
11-7. Chime Bell operation
     When the guest presses ESC(Bell) Button from the keypad, Chime Bell melody is
     activating for 5 seconds.


12. Setting Changes
To change previous setting values, you need Master Card(or PIN) to get in to Setting Change mode.
First present Master Card(or press Master PIN) and enter 2-digit command code.
                    Present Master Card(or PIN) and press 2digit command code.


                    + Command code +

   Command Change setting values
      11    Add User Access Cards(RF CARD ONLY MODE)
      12    Add User Access Cards and PIN(RF CARD + PIN MODE)
      13    Add User Access PIN numbers(PIN ONLY MODE)
      14    Delete User Access Cards(or PIN)
      21    Change Door open time when User Access Card(or PIN) is granted
      22    Change Alarm time when User Access Card(or PIN) is denied
      23    Change Alarm time when Try Our error detected
      24    Change Alarm time when Door Contact error detected
      25    Change Alarm time when AUX#1 Input detected
      26    Change Alarm time when AUX#2 Input detected
      27    Change Alarm time when AUX#3 Input detected
      28    Change Alarm time when magnet detected
      29    Register 2 digits Duress Alarm Code
      30    Change Alarm time when Duress Alarm detected
      31    Test Door open time set by command "21"
      32    Test Alarm time set by command "22"
      33    Test Alarm time set by command "23"
      34    Test Alarm time set by command "24"
      35    Test Alarm time set by command "25"
      36    Test Alarm time set by command "26"
      37    Test Alarm time set by command "27"
      39    Change Chime Bell activating time




                                               - 13 -


                                                                   MOTOROLA
SDC1000                                          SINGLE DOOR ACCESS CONTROLLER
  Command Change setting values
     41    Unconditional Door Open
     42    Unconditional Door Close
     43    Enable QUICK ACCESS MODE(Operate only PIN MODE)
     44    Disable QUICK ACCESS MODE(Operate only PIN MODE)
     51    Disable Melody sound
     52    Enable Melody sound
     60    Change keypad lock time when Try Out error detected
     61    Detect AUX#1 Input from 'L' to ‘H'
     62    Detect AUX#1 Input from 'H' to ‘L'
     63    Detect AUX#2 Input from 'L' to ‘H'
     64    Detect AUX#2 Input from 'H' to ‘L'
     65    Detect AUX#3 Input from 'L' to ‘H'
     66    Detect AUX#3 Input from 'H' to ‘L'
     67    Detect Exit Button Input from 'L' to 'H'
     68    Detect Exit Button Input from 'H' to 'L'
     69    Detect Door Contact sensor Input from 'L' to 'H'
     70    Detect Door Contact sensor Input from 'H' to 'L'
     71    Activate TTL output to ‘H'
     72    Activate TTL output to ‘L'
     77    Enable Chime Bell Output
     78    Disable Chime Bell Output
     80    Set delay time to activate SECURE MODE
     81    Set watch-dog time for Door Contact sensor
     82    Set number of times of Try-Out
     83    Set input limit time from the keypad
     84    Set Temper Alarm port
     88    Enable Temper Alarm
     89    Disable temper Alarm
     99    Initialize and erase all setup data




                                       - 14 -


                                                                                     MOTOROLA
SDC1000                                                            SINGLE DOOR ACCESS CONTROLLER
12-11. Add User Access Cards(RF CARD ONLY MODE)




                  11ENT                                 .....

   Master card   Command     Cards to be registered ....             Master card


12-12. Add User Access Cards(RF CARD + PIN MODE)



                  12ENT                   PINENT          .....

   Master card   Command     Cards to be registered ....             Master card


12-13. Add User Access PIN(PIN ONLY MODE)

  MasterPINENT    13ENT         PINENT .....                         MasterPINENT
    Master PIN   Command   PIN to be registered ....               Master PIN


12-14.1. Delete User Access Cards(RF CARD ONLY MODE, RF CARD+PIN MODE)



                  14ENT      CardNumberENT                .....

   Master Card   Command     Cards to be deleted ....                 Master Card


12-14.2. Delete User Access PIN(PIN ONLY MODE)

  MasterPINENT    14ENT        PINENT .....                         MasterPINENT
    Master PIN   Command    PIN to be deleted ....                Master PIN




                                              - 15 -


                                                                                   MOTOROLA
SDC1000                                                      SINGLE DOOR ACCESS CONTROLLER


<Table 1> Settings for command 21~28


  Symbol   Setting Values                                       Examples/Remarks


           (You must add value ¨ ç and ¨ è)
                                                               EX1)Act ivate Door Relay
           Setting value for activating time
                                                                   all the time
           ¨ çActivate Time                          Value
                                                                   Door RELAY          01
              Activate only Secure Mode              : 00
                                                                   All the time        50
              Activate all the time                  : 50
                                                                                OM =   51
 Output    ____________________________________________
 Mode      Setting Value for activate Output Port
                                                               EX2)Activate Alarm Relay
   OM      ¨ èActivate Output Port                   Value
                                                                   and TTL during the
              Activate only Door Relay               : 01
                                                                   Secure mode
              Activate only Alarm Relay              : 02
                                                                   Alarm+TTL           06
              Activate only TTL Output               : 04
                                                                   Secure Mode         00
              Activate Door Relay & TTL                 : 05
                                                                                OM =   06
              Activate Alarm Relay & TTL             : 06


            tt is the activating time value(seconds)            tt value 00sec. means
    tt
            from 01sec. to 99sec.                               no operation.


           PW is the 2 digits PassWord for                      Do not use ‘77’ as it Is
    PW
           Duress Alarm.                                        used for Secure Mode


           mm is activating time value(minutes)                 mm value 00min. means
    mm
            from 01min. to 99min.                               no operation.




                                            - 16 -


                                                                                        MOTOROLA
SDC1000                                                       SINGLE DOOR ACCESS CONTROLLER

12-21. Change Door open time when User Access Card(or PIN) is granted
                    (Please refer to Table 1 for tt)


                     21ENT         ttENT              ttENT
  Master card or   Command      Door time     TTL time
  MasterPINENT
12-22. Change Alarm time when User Access Card(or PIN) is denied
                    (Please refer to Table 1 for OM, tt)


                     22ENT        OMENT           ttENT           ttENT         ttENT
  Master card or   Command     Output Mode    Door time       Alarm Time   TTL time
  MasterPINENT


12-23. Change Alarm time when Try Our error detected
                    (Please refer to Table 1 for OM, tt)


                     23ENT        OMENT           ttENT           ttENT         ttENT
  Master card or   Command    Output Mode    Door Time        Alarm Time   TTL Time
  MasterPINENT

12-24. Change Alarm time when Door Contact error detected
                    (Please refer to Table 1 for OM, tt)

                     24ENT        OMENT           ttENT           ttENT         ttENT
  Master card or   Command    Output Mode    Door Time        Alarm Time   TTL Time
  MasterPINENT

12-25. Change Alarm time when AUX#1 Input detected
12-26. Change Alarm time when AUX#2 Input detected
12-27. Change Alarm time when AUX#3 Input detected
                    (Please refer to Table 1 for OM, tt)
                     25ENT
                     26ENT         OMENT        ttENT             ttENT         ttENT
                     27ENT
  Master card or   Command    Output Mode    Door Time        Alarm Time   TTL Time
  MasterPINENT




                                             - 17 -


                                                                                      MOTOROLA
SDC1000                                                      SINGLE DOOR ACCESS CONTROLLER

12-28. Change Alarm time when magnet detected
                       (Please refer to Table 1 for OM, tt)

                        28ENT         OMENT          ttENT       ttENT        ttENT
  Master card or     Command      Output Mode   Door Time    Alarm Time   TTL Time
  MasterPINENT

12-29. Register 2 digits Duress Alarm PassWord
                       (Please refer to Table 1 for PW)


                        29ENT         PW
  Master card or     Command      PassWord
  MasterPINENT

  * ‘00’ is registered as default PassWord.


12-30. Change Alarm time when Duress Alarm detected
                       (Please refer to Table 1 for OM, tt)

                        30ENT         OMENT          ttENT       ttENT        ttENT
  Master card or     Command      Output Mode   Door Time    Alarm Time   TTL Time
  MasterPINENT

12-31. Test Door open time set by command "21"
12-32. Test Alarm time set by command "22"
12-33. Test Alarm time set by command "23"
12-34. Test Alarm time set by command "24"
12-35. Test Alarm time set by command "25"
12-36. Test Alarm time set by command "26"
12-37. Test Alarm time set by command "27"
                   Outputs set by command will be tested.


                        31~37ENT
  Master card or       Command
  MasterPINENT




                                                - 18 -


                                                                          MOTOROLA
SDC1000                                                 SINGLE DOOR ACCESS CONTROLLER

12-39. Change Chime Bell activating time
                     (Please refer to Table 1 for tt)


                      39ENT         ttENT
  Master card or   Command     Chime Bell Time
  MasterPINENT


12-41. Unconditional Door Open
  Master card or   41ENT
  MasterPINENT

12-42. Unconditional Door Close
  Master card or   42ENT
  MasterPINENT

12-43. Enable QUICK ACCESS MODE
  When QUICK ACCESS MODE is enabled in PIN ONLY MODE,
  Door will open just press ENT key.
  Master card or   43ENT
  MasterPINENT

12-44. Disable QUICK ACCESS MODE
  Master card or   44ENT
  MasterPINENT

12-51. Disable Melody sound
  Master card or   51ENT
  MasterPINENT

12-52. Enable Melody sound
  Master card or   52ENT
  MasterPINENT

12-60. Change keypad lock time when Try Out error detected
                     (Please refer to Table 1 for tt)


                      60ENT         ttENT
  Master card or   Command     Keypad Lock Time
  MasterPINENT




                                             - 19 -


                                                                                      MOTOROLA
SDC1000                                                             SINGLE DOOR ACCESS CONTROLLER
12-61. Detect AUX#1 Input from 'L' to ‘H'
  AUX#1 input is detected on the raising edge of AUX#1 input
  Master card or       61ENT
  MasterPINENT

12-62. Detect AUX#1 Input from 'H' to ‘L'
  AUX#1 input is detected on the falling edge of AUX#1 input
  Master card or       62ENT
  MasterPINENT

12-63. Detect AUX#2 Input from 'L' to ‘H'
  AUX#2 input is detected on the raising edge of AUX#2 input
  Master card or       63ENT
  MasterPINENT

12-64. Detect AUX#2 Input from 'H' to ‘L'
  AUX#2 input is detected on the falling edge of AUX#2 input
  Master card or       64ENT
  MasterPINENT

12-65. Detect AUX#3 Input from 'L' to ‘H'
  AUX#3 input is detected on the raising edge of AUX#3 input
  Master card or       65ENT
  MasterPINENT

12-66. Detect AUX#3 Input from 'H' to ‘L'
  AUX#3 input is detected on the falling edge of AUX#3 input
  Master card or       66ENT
  MasterPINENT

12-67. Detect Exit Button Input from 'L' to 'H'
  Exit Button input is detected on the raising edge of Exit Button input
  Master card or       67ENT
  MasterPINENT

12-68. Detect Exit Button Input from 'H' to 'L'
  Exit Button input is detected on the falling edge of Exit Button input
  Master card or       68ENT
  MasterPINENT

12-69. Detect Door Contact sensor Input from 'L' to 'H'
  Door Contact input is detected on the raising edge of Door Contact input
  Master card or       69ENT
  MasterPINENT




                                                      - 20 -


                                                                                        MOTOROLA
SDC1000                                                               SINGLE DOOR ACCESS CONTROLLER
12-70. Detect Door Contact sensor Input from 'H' to 'L'
  Door Contact input is detected on the falling edge of Door Contact input
  Master card or        70ENT
  MasterPINENT

12-71. Activate TTL output to ‘H'
  TTL output changes the state from logic '0' to logic '1' when it activates.
  Master card or        71ENT
  MasterPINENT

12-72. Activate TTL output to ‘L'
  TTL output changes the state from logic '1' to logic '0' when it activates.
  Master card or        72ENT
  MasterPINENT

12-77. Enable Chime Bell Output
  Master card or   77ENT
  MasterPINENT

12-78. Disable Chime Bell Output
  Master card or   78ENT
  MasterPINENT

12-80. Set delay time to activate SECURE MODE
                          (Please refer to Table 1 for mm)


                            80ENT          mmENT
  Master card or        Command         Delay Time
  MasterPINENT

12-81. Set watch-dog time for Door Contact sensor
                          (Please refer to Table 1 for tt)


                           81ENT             ttENT
  Master card or        Command        Watch-dog Time
  MasterPINENT




                                                       - 21 -


                                                                             MOTOROLA
SDC1000                                                  SINGLE DOOR ACCESS CONTROLLER

12-82. Set number of times of Try-Out
                NN is the Try-out numbers from 00 to 99 times.


                       82ENT         NNENT
  Master card or    Command     Try-out Numbers
  MasterPINENT

12-83. Set input limit time from the keypad
                      (Please refer to Table 1 for tt from 10 ~ 99)


                       83ENT         ttENT
  Master card or    Command     Input Limit Time
  MasterPINENT

12-84. Set Temper Alarm port
                     (Please refer to Table 1 for OM)

                       84ENT         OMENT
  Master card or    Command      Alarm Port
  MasterPINENT

12-88. Enable Temper Alarm
  Master card or  88ENT
  MasterPINENT

12-89. Disable temper Alarm
  Master card or    89ENT
  MasterPINENT

12-99. Initialize and erase all setup data
  Please use this command when you really want to erase all data and start
  the unit from the begining.

  Master card or    99ENT
  MasterPINENT




                                               - 22 -


                                                                                                        MOTOROLA
SDC1000                                                                    SINGLE DOOR ACCESS CONTROLLER

13. FCC REGISTRATION INFORMATION

FCC REQUIREMENTS PART 15

Caution: Any changes or modifications in construction of this device which are not expressly approved by the responsible
for compliance cold void the user's authority to operate the equipment.

NOTE: This device complies with Part 15 of the FCC Rules.

Operation is subject to the following two conditions;
1. This device may not cause harmful interface, and
2. This device must accept any interference received, including interference that may cause undesired
   operation.

This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15
of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when
the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio
frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful
interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful
interference in which case the user will be required to correct the interference at his own expense.




                                                            - 23 -


                                                                                                              MOTOROLA
SDC1000                                                                      SINGLE DOOR ACCESS CONTROLLER

14. Warranty and Service
The following warranty and service information applies only to the United States of America and Republic of Korea. For
the information in other countries, please contact your local distributor.
To obtain in or out of warranty service, please prepay shipment and return the unit to the appropriate facility listed below.

IN THE UNITED STATES

RF LOGICS Inc. Service Center
3026 Scott Blvd.,
SANTA CLARA, CA95054 USA
Tel.:    (408) 980-0001
Fax.:    (408) 980-8060
E-mail: rflogics@rflogics.com
Web-site: www.rflogics.com

OUTSIDE OF THE UNITED STATES

ID TECK CO., LTD. Service Center
5F Ace Techno Tower Bldg.,
684-1 Deungchon-dong, Gangsuh-gu,
SEOUL 157-030, KOREA
Tel.:    +82 (2) 659-0055
Fax.:    +82 (2) 659-0086
E-mail: webmaster@idteck.com
Web-site: www.idteck.com

Please use the original container, or pack the unit(s) in a sturdy carton with sufficient packing to prevent damage, include
the following information:
1. A proof-of-purchase indicating model number and date of purchase.
2. Bill-to address
3. Ship-to address
4. Number and description of units shipped.
5. Name and telephone number of person to contact.
6. Reason for return and description of the problem.

NOTE: Damage occuring during shipment is deemed the responsibility of the carrier, and claims should be made directly to
    the carrier.




                                                              - 24 -



Document Created: 2019-09-01 00:55:31
Document Modified: 2019-09-01 00:55:31

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC