Test report (DXX)

FCC ID: E8HKC-1907

Test Report

Download: PDF
FCCID_4503854

                                                               FCC Test Report

                       Report No.: RF191016D01

                             FCC ID: E8HKC-1907

                       Test Model: KB7120Wc

                 Received Date: Oct. 16, 2019

                         Test Date: Oct. 22 to 30, 2019

                     Issued Date: Nov. 1, 2019


                         Applicant: Chicony Electronics Co., Ltd.

                           Address: No.69, Sec. 2, Guangfu Rd., Sanchong Dist., New Taipei City 241,
                                    Taiwan(R.O.C.)

                        Issued By: Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch
                                   Lin Kou Laboratories
                    Lab Address: No. 47-2, 14th Ling, Chia Pau Vil., Lin Kou Dist., New Taipei City, Taiwan
       FCC Registration /
      Designation Number: 198487 / TW2021




This report is for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted
only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this
report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product
unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you
provided to us. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence, provided,
however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time
shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Unless specific
mention, the uncertainty of measurement has been explicitly taken into account to declare the compliance or non-compliance to the specification. The report
must not be used by the client to claim product certification, approval, or endorsement by TAF or any government agencies.



Report No.: RF191016D01                                              Page No. 1 / 24                                            Report Format Version: 6.1.1


                                                                   Table of Contents
Release Control Record .................................................................................................................................. 3
1         Certificate of Conformity...................................................................................................................... 4
2         Summary of Test Results ..................................................................................................................... 5
    2.1      Measurement Uncertainty ................................................................................................................... 5
    2.2      Modification Record ............................................................................................................................ 5
3         General Information .............................................................................................................................. 6
    3.1      General Description of EUT ................................................................................................................ 6
    3.2      Description of Test Modes ................................................................................................................... 7
    3.2.1    Test Mode Applicability and Tested Channel Detail............................................................................. 8
    3.3      Description of Support Units ............................................................................................................... 9
    3.3.1    Configuration of System under Test .................................................................................................... 9
    3.4      General Description of Applied Standards .......................................................................................... 9
4         Test Types and Results ...................................................................................................................... 10
    4.1      Radiated Emission and Bandedge Measurement............................................................................. 10
    4.1.1    Limits of Radiated Emission and Bandedge Measurement .............................................................. 10
    4.1.2    Test Instruments ................................................................................................................................. 11
    4.1.3    Test Procedures................................................................................................................................. 12
    4.1.4    Deviation from Test Standard ............................................................................................................ 12
    4.1.5    Test Setup .......................................................................................................................................... 13
    4.1.6    EUT Operating Conditions................................................................................................................. 14
    4.1.7    Test Results ....................................................................................................................................... 15
    4.2      Channel Bandwidth ........................................................................................................................... 21
    4.2.1    Test Setup .......................................................................................................................................... 21
    4.2.2    Test Instruments ................................................................................................................................ 21
    4.2.3    Test Procedure .................................................................................................................................. 21
    4.2.4    Deviation from Test Standard ............................................................................................................ 21
    4.2.5    EUT Operating Condition .................................................................................................................. 21
    4.2.6    Test Results ....................................................................................................................................... 22
5         Pictures of Test Arrangements .......................................................................................................... 23
Appendix – Information of the Testing Laboratories ................................................................................. 24




Report No.: RF191016D01                                              Page No. 2 / 24                                             Report Format Version: 6.1.1


                                              Release Control Record


 Issue No.                Description                                        Date Issued
 RF191016D01              Original release.                                  Nov. 1, 2019




Report No.: RF191016D01                           Page No. 3 / 24      Report Format Version: 6.1.1


1   Certificate of Conformity


            Product: Wireless Keyboard

              Brand: DELL

        Test Model: KB7120Wc

    Sample Status: Engineering sample

          Applicant: Chicony Electronics Co., Ltd.

          Test Date: Oct. 22 to 30, 2019

         Standards: 47 CFR FCC Part 15, Subpart C (Section 15.249)
                          ANSI C63.10: 2013



The above equipment has been tested by Bureau Veritas Consumer Products Services (H.K.) Ltd.,
Taoyuan Branch, and found compliance with the requirement of the above standards. The test record, data
evaluation & Equipment Under Test (EUT) configurations represented herein are true and accurate accounts
of the measurements of the sample’s RF characteristics under the conditions specified in this report.




     Prepared by :                                                      , Date:          Nov. 1, 2019
                                Annie Chang / Senior Specialist




     Approved by :                                                      , Date:          Nov. 1, 2019
                             Rex Lai / Associate Technical Manager




Report No.: RF191016D01                        Page No. 4 / 24                        Report Format Version: 6.1.1


2     Summary of Test Results


                             47 CFR FCC Part 15, Subpart C (SECTION 15.249)

       FCC
                                Test Item                      Result                 Remarks
      Clause
      15.207         AC Power Conducted Emission                N/A     Power supply is 3Vdc from batteries
      15.215       Channel Bandwidth Measurement         -
                 Radiated Emission Test
                 Band Edge Measurement
     15.209                                                        Meet the requirement of limit.
                 Limit: 50dB less than the peak
     15.249                                               PASS     Minimum passing margin is
                 value of fundamental frequency or
   15.249 (d)                                                      -9.54dB at 2400.00MHz.
                 meet radiated emission limit in
                 section 15.209
     15.203      Antenna Requirement                      PASS     No antenna connector is used.
Note: Determining compliance based on the results of the compliance measurement, not taking into account
measurement instrumentation uncertainty.



2.1    Measurement Uncertainty
Where relevant, the following measurement uncertainty levels have been estimated for tests performed on
the EUT as specified in CISPR 16-4-2:

                                                                                     Expanded Uncertainty
                   Measurement                                  Frequency
                                                                                          (k=2) (±)
                                                          9kHz ~ 30MHz                     2.38 dB
         Radiated Emissions up to 1 GHz
                                                        30MHz ~ 1000MHz                    5.43 dB
         Radiated Emissions above 1 GHz                    Above 1GHz                      5.42 dB




2.2    Modification Record
There were no modifications required for compliance.




Report No.: RF191016D01                      Page No. 5 / 24                           Report Format Version: 6.1.1


3     General Information
3.1     General Description of EUT

 Product                     Wireless Keyboard
 Brand                       DELL
 Test Model                  KB7120Wc
 Status of EUT               Engineering sample
 Power Supply Rating         3.0Vdc from batteries
 Modulation Type             GFSK
 Operating Frequency         2402MHz ~2479MHz
 Number of Channel           78
 Antenna Type                PCB antenna with -0.81dBi gain
 Antenna Connector           N/A
 Accessory Device            N/A
 Data Cable Supplied         N/A
Note:
1. Bluetooth & GFSK technologies can not transmit at same time.
2. The above EUT information is declared by manufacturer and for more detailed features description,
   please refer to the manufacturer's specifications or user's manual.




Report No.: RF191016D01                     Page No. 6 / 24                       Report Format Version: 6.1.1


3.2   Description of Test Modes
78 channels are provided to this EUT:

                 FREQ.                  FREQ.                   FREQ.                    FREQ.
 CHANNEL                   CHANNEL                  CHANNEL             CHANNEL
                 (MHz)                  (MHz)                   (MHz)                    (MHz)
      0           2402          20      2422               40   2442       60             2462
      1           2403          21      2423               41   2443       61             2463
      2           2404          22      2424               42   2444       62             2464
      3           2405          23      2425               43   2445       63             2465
      4           2406          24      2426               44   2446       64             2466
      5           2407          25      2427               45   2447       65             2467
      6           2408          26      2428               46   2448       66             2468
      7           2409          27      2429               47   2449       67             2469
      8           2410          28      2430               48   2450       68             2470
      9            2411         29      2431               49   2451       69             2471
      10          2412          30      2432               50   2452       70             2472
      11          2413          31      2433               51   2453       71             2473
      12          2414          32      2434               52   2454       72             2474
      13          2415          33      2435               53   2455       73             2475
      14          2416          34      2436               54   2456       74             2476
      15          2417          35      2437               55   2457       75             2477
      16          2418          36      2438               56   2458       76             2478
      17          2419          37      2439               57   2459       77             2479
      18          2420          38      2440               58   2460
      19          2421          39      2441               59   2461




Report No.: RF191016D01                  Page No. 7 / 24                 Report Format Version: 6.1.1


3.2.1       Test Mode Applicability and Tested Channel Detail

 EUT Configure                         Applicable To
                                                                                              Description
     Mode
                        RE1G       RE<1G          PLC              APCM

        -                 √           √            Note               √     -
              RE1G: Radiated Emission above 1GHz &
Where                                                        RE<1G: Radiated Emission below 1GHz
              Bandedge Measurement
              PLC: Power Line Conducted Emission             APCM: Antenna Port Conducted Measurement
NOTE : No need to concern of Conducted Emission due to the EUT is powered by batteries.

 Radiated Emission Test (Above 1GHz):
    Pre-Scan has been conducted to determine the worst-case mode from all possible combinations
    between available modulations, data rates and antenna ports (if EUT with antenna diversity
    architecture).
    Following channel(s) was (were) selected for the final test as listed below.
        EUT Configure Mode                Available Channel                Tested Channel               Modulation Type

                    -                          0 to 77                          0, 38, 77                     GFSK


 Radiated Emission Test (Below 1GHz):
    Pre-Scan has been conducted to determine the worst-case mode from all possible combinations
    between available modulations, data rates and antenna ports (if EUT with antenna diversity
    architecture).
    Following channel(s) was (were) selected for the final test as listed below.
        EUT Configure Mode                Available Channel                Tested Channel               Modulation Type

                    -                          0 to 77                             0                          GFSK


 Antenna Port Conducted Measurement:
    This item includes all test value of each mode, but only includes spectrum plot of worst value of each
    mode.
    Pre-Scan has been conducted to determine the worst-case mode from all possible combinations
    between available modulations, data rates and antenna ports (if EUT with antenna diversity
    architecture).
    Following channel(s) was (were) selected for the final test as listed below.
        EUT Configure Mode                Available Channel                Tested Channel               Modulation Type

                    -                          0 to 77                          0, 38, 77                     GFSK


 Test Condition:
             Applicable To           Environmental Conditions               Input Power                     Tested By
                RE1G                     23deg. C, 78%RH                       3.0Vdc                      Dalen Dai
                RE<1G                     23deg. C, 78%RH                       3.0Vdc                      Dalen Dai
                APCM                      25deg. C, 76%RH                       3.0Vdc                      Saxon Lee




Report No.: RF191016D01                                  Page No. 8 / 24                           Report Format Version: 6.1.1


3.3     Description of Support Units
The EUT has been tested as an independent unit together without any necessary accessory or support unit.

3.3.1    Configuration of System under Test




                                                        EUT




                                            (Powered from batteries)




3.4     General Description of Applied Standards


 The EUT is a RF Product. According to the specifications of the manufacturer, it must comply with the
 requirements of the following standards:

 FCC Part 15, Subpart C (15.249)
 ANSI C63.10-2013

 All test items have been performed and recorded as per the above standards.




Report No.: RF191016D01                       Page No. 9 / 24                       Report Format Version: 6.1.1


4       Test Types and Results
4.1     Radiated Emission and Bandedge Measurement
4.1.1    Limits of Radiated Emission and Bandedge Measurement

The field strength of emissions from intentional radiators operated within these frequency bands shall comply
with the following

           Fundamental             Field Strength of Fundamental           Field Strength of Harmonics
            Frequency                     (millivolts/meter)                    (microvolts/meter)

          902 ~ 928 MHz                           50                                   500
        2400 ~ 2483.5 MHz                         50                                   500
         5725 ~ 5875 MHz                          50                                   500
          24 ~ 24.25 GHz                         250                                   2500


Emissions radiated outside of the specified frequency bands, except for harmonics, shall be attenuated by
at least 50 dB below the level of the fundamental or to the general radiated emission limits as below table,
whichever is the lesser attenuation

             Frequencies                        Field Strength                   Measurement Distance
                (MHz)                         (microvolts/meter)                       (meters)

            0.009 ~ 0.490                        2400/F(kHz)                               300

            0.490 ~ 1.705                       24000/F(kHz)                                 30
             1.705 ~ 30.0                              30                                    30
               30 ~ 88                                 100                                    3
              88 ~ 216                                 150                                    3
              216 ~ 960                                200                                    3
             Above 960                                 500                                    3
NOTE:
1.  The lower limit shall apply at the transition frequencies.
2.  Emission level (dBuV/m) = 20 log Emission level (uV/m).
3.  For frequencies above 1000MHz, the field strength limits are based on average detector, however, the
    peak field strength of any emission shall not exceed the maximum permitted average limits, specified
    above by more than 20dB under any condition of modulation.




Report No.: RF191016D01                        Page No. 10 / 24                        Report Format Version: 6.1.1


4.1.2   Test Instruments

    DESCRIPTION &                                                          CALIBRATED CALIBRATED
                                MODEL NO.                 SERIAL NO.
    MANUFACTURER                                                                DATE             UNTIL
HP Preamplifier                     8447D                 2432A03504       Feb. 20, 2019     Feb. 19, 2020
HP Preamplifier                      8449B                3008A01201       Feb. 21, 2019     Feb. 20, 2020
MITEQ Preamplifier         AMF-6F-260400-33-8P              892164         Feb. 20, 2019     Feb. 19, 2020
Agilent
                                   N9038A                 MY51210129       Mar. 05, 2019     Mar. 04, 2020
TEST RECEIVER
Schwarzbeck Antenna              VULB 9168                    139          Nov. 26, 2018     Nov. 25, 2019
Schwarzbeck Antenna              VHBA 9123                    480           Jun. 3, 2019      Jun. 2, 2021
Schwarzbeck Horn
                                 BBHA-9170                    212          Nov. 25, 2018     Nov. 24, 2019
Antenna
Schwarzbeck Horn
                               BBHA 9120-D1                   D130         Nov. 25, 2018     Nov. 24, 2019
Antenna
ADT. Turn Table                      TT100                    0306                NA                NA
ADT. Tower                           AT100                    0306                NA                NA
Software                    Radiated_V7.6.15.9.5               NA                 NA                NA
SUHNER RF cable
                                    SF102                Cable-CH6-01       Jul. 10, 2019      Jul. 9, 2020
With 4dB PAD
SUHNER RF cable
                                    SF102              Cable-CH8-3.6m       Jul. 10, 2019      Jul. 9, 2020
With 3/4dB PAD
KEYSIGHT MIMO
Powermeasurement Test              U2021XA               U2021XA-001       Jun. 11, 2019     Jun. 10, 2020
set
KEYSIGHT
                                   N9030A                 MY54490260        Jul. 30, 2019     Jul. 29, 2020
Spectrum Analyzer
Loop Antenna EMCI                   LPA600                    270          Aug. 23, 2019    Aug. 22, 2021
EMCO Horn Antenna                     3115                 00028257        Nov. 25, 2018     Nov. 24, 2019
Highpass filter
                             WHK 3.1/18G-10SS                 SN 8                NA                NA
Wainwright Instruments
ROHDE & SCHWARZ
                                    FSV40                    101042        Sep. 23, 2019    Sep. 22, 2020
Spectrum Analyzer
Anritsu
                                  MA2411B                   0738404        Apr. 16, 2019     Apr. 15, 2020
Power Sensor
Anritsu
                                   ML2495A                  0842014        Apr. 16, 2019     Apr. 15, 2020
Power Meter
 NOTE: 1. The calibration interval of the above test instruments is 12/24 months. And the calibrations are
            traceable to NML/ROC and NIST/USA.
        2. The horn antenna and HP preamplifier (model: 8449B) are used only for the measurement of
            emission frequency above 1GHz if tested.
        3. The test was performed in Chamber No. 6.




Report No.: RF191016D01                      Page No. 11 / 24                       Report Format Version: 6.1.1


4.1.3      Test Procedures

For Radiated emission below 30MHz
 a. The EUT was placed on the top of a rotating table 0.8 meters above the ground at a 3 meter chamber
    room. The table was rotated 360 degrees to determine the position of the highest radiation.
     b. The EUT was set 3 meters away from the interference-receiving antenna, which was mounted on the top
        of a variable-height antenna tower.
     c. Parallel, perpendicular, and ground-parallel orientations of the antenna are set to make the measurement.
     d. For each suspected emission, the EUT was arranged to its worst case and the rotatable table was turned
        from 0 degrees to 360 degrees to find the maximum reading.
     e. The test-receiver system was set to Quasi-Peak Detect Function and Specified Bandwidth with
        Maximum Hold Mode.
NOTE:
 1. The resolution bandwidth and video bandwidth of test receiver/spectrum analyzer is 9kHz at frequency
    below 30MHz.

For Radiated emission above 30MHz
a. The EUT was placed on the top of a rotating table 0.8 meters (for 30MHz ~ 1GHz) / 1.5 meters (for
    above 1GHz) above the ground at 3 meter chamber room for test. The table was rotated 360 degrees to
    determine the position of the highest radiation.
b.      The EUT was set 3 meters away from the interference-receiving antenna, which was mounted on the
        top of a variable-height antenna tower.
c.      The height of antenna is varied from one meter to four meters above the ground to determine the
        maximum value of the field strength. Both horizontal and vertical polarizations of the antenna are set to
        make the measurement.
d.      For each suspected emission, the EUT was arranged to its worst case and then the antenna was tuned
        to heights from 1 meter to 4 meters and the rotatable table was turned from 0 degrees to 360 degrees to
        find the maximum reading.
e.      The test-receiver system was set to quasi-peak detect function and specified bandwidth with maximum
        hold mode when the test frequency is below 1 GHz.
f.      The test-receiver system was set to peak and average detect function and specified bandwidth with
        maximum hold mode when the test frequency is above 1 GHz. If the peak reading value also meets
        average limit, measurement with the average detector is unnecessary.

Note:
1. The resolution bandwidth and video bandwidth of test receiver/spectrum analyzer is 120kHz for Quasi-
    peak detection (QP) at frequency below 1GHz.
2.      The resolution bandwidth of test receiver/spectrum analyzer is 1 MHz and the video bandwidth is 3 MHz
        for Peak detection (PK) at frequency above 1GHz.
3.      The resolution bandwidth of test receiver/spectrum analyzer is 1MHz and the video bandwidth is ≥ 1/T
        (Duty cycle < 98%) or 10Hz (Duty cycle ≥ 98%) for Average detection (AV) at frequency above 1GHz.
4.      All modes of operation were investigated and the worst-case emissions are reported.


4.1.4      Deviation from Test Standard

     No deviation.




Report No.: RF191016D01                           Page No. 12 / 24                        Report Format Version: 6.1.1


4.1.5   Test Setup

 For Radiated emission below 30MHz


                                                                    1m
           EUT&                        3m
           Support Units

                             Turn Table

              80cm


                                     Ground Plane
                                     Test Receiver




 For Radiated emission 30MHz to 1GHz

                                                       Ant. Tower
                                                                     1-4m
                                                                     Variable
             EUT&
                                          3m
                                           10m
             Support Units

                                 Turn Table

                 80cm


                                       Ground Plane

                                       Test Receiver




Report No.: RF191016D01                 Page No. 13 / 24                 Report Format Version: 6.1.1


 For Radiated emission above 1GHz



                                                 Ant. Tower              1-4m
                                                                         Variable
 EUT&                               3m
 Support Units

                          Turn Table
                                         Absorber

    150cm


                                 Ground Plane
                                 Test Receiver




 For the actual test configuration, please refer to the attached file (Test Setup Photo).




4.1.6   EUT Operating Conditions

   Set the EUT under transmission condition continuously at specific channel frequency.




Report No.: RF191016D01                         Page No. 14 / 24                            Report Format Version: 6.1.1


4.1.7   Test Results
ABOVE 1GHz DATA
 CHANNEL                   TX Channel 0            DETECTOR                 Peak (PK)
 FREQUENCY RANGE           1GHz ~ 25GHz            FUNCTION                 Average (AV)


                   ANTENNA POLARITY & TEST DISTANCE: HORIZONTAL AT 3 M
                    EMISSION                          ANTENNA     TABLE        RAW      CORRECTION
        FREQ.                    LIMIT    MARGIN
 NO.                 LEVEL                             HEIGHT     ANGLE       VALUE       FACTOR
        (MHz)                  (dBuV/m)    (dB)
                    (dBuV/m)                             (m)     (Degree)     (dBuV)       (dB/m)
  1      2390.00    48.05 PK     74.00    -25.95        1.42 H     305         47.47        0.58
  2      2390.00    34.09 AV     54.00    -19.91        1.42 H     305         33.51        0.58
  3      2400.00    64.46 PK     74.00     -9.54        1.42 H     305         63.85        0.61
  4      2400.00    36.83 AV     54.00    -17.17        1.42 H     305         36.22        0.61
  5     *2402.00    94.09 PK    114.00    -19.91        1.42 H     305         93.48        0.61
  6     *2402.00    67.79 AV     94.00    -26.21        1.42 H     305         67.18        0.61
  7      4804.00    52.88 PK     74.00    -21.12        1.16 H     88          44.62        8.26
  8      4804.00    26.58 AV     54.00    -27.42        1.16 H     88          18.32        8.26
  9      7206.00    58.99 PK     74.00    -15.01        1.23 H     341         45.85        13.14
  10     7206.00    32.69 AV     54.00    -21.31        1.23 H     341         19.55        13.14
                    ANTENNA POLARITY & TEST DISTANCE: VERTICAL AT 3 M
                    EMISSION                          ANTENNA     TABLE        RAW      CORRECTION
        FREQ.                    LIMIT    MARGIN
 NO.                 LEVEL                             HEIGHT     ANGLE       VALUE       FACTOR
        (MHz)                  (dBuV/m)    (dB)
                    (dBuV/m)                             (m)     (Degree)     (dBuV)       (dB/m)
  1      2390.00    46.02 PK     74.00    -27.98        4.00 V     248         45.44        0.58
  2      2390.00    32.75 AV     54.00    -21.25        4.00 V     248         32.17        0.58
  3      2400.00    60.49 PK     74.00    -13.51        4.00 V     248         59.88        0.61
  4      2400.00    35.92 AV     54.00    -18.08        4.00 V     248         35.31        0.61
  5     *2402.00    91.15 PK    114.00    -22.85        4.00 V     248         90.54        0.61
  6     *2402.00    64.85 AV     94.00    -29.15        4.00 V     248         64.24        0.61
  7      4804.00    55.29 PK     74.00    -18.71        2.09 V     67          47.03        8.26
  8      4804.00    28.99 AV     54.00    -25.01        2.09 V     67          20.73        8.26
  9      7206.00    57.29 PK     74.00    -16.71        1.63 V     33          44.15        13.14
  10     7206.00    30.99 AV     54.00    -23.01        1.63 V     33          17.85        13.14
REMARKS:
   1. Emission Level(dBuV/m) = Raw Value(dBuV) + Correction Factor(dB/m)
   2. Correction Factor(dB/m) = Antenna Factor(dB/m) + Cable Factor(dB) – Pre-Amplifier Factor(dB)
   3. Margin value = Emission Level – Limit value
   4. The other emission levels were very low against the limit.
   5. " * ": Fundamental frequency.
   6. The average value of fundamental and harmonic frequency is: Average = Peak value + 20 log(Duty
      cycle) Where the duty factor is calculated from following formula:
      20 log(Duty cycle) = 20 log(0.046 ms / 0.954 ms) = -26.3 dB
      Please see page 18 for plotted duty.




Report No.: RF191016D01                    Page No. 15 / 24                       Report Format Version: 6.1.1


 CHANNEL                   TX Channel 38            DETECTOR                 Peak (PK)
 FREQUENCY RANGE           1GHz ~ 25GHz             FUNCTION                 Average (AV)


                  ANTENNA POLARITY & TEST DISTANCE: HORIZONTAL AT 3 M
                    EMISSION                           ANTENNA     TABLE        RAW      CORRECTION
        FREQ.                    LIMIT     MARGIN
 NO.                 LEVEL                              HEIGHT     ANGLE       VALUE       FACTOR
        (MHz)                  (dBuV/m)     (dB)
                    (dBuV/m)                              (m)     (Degree)     (dBuV)       (dB/m)
  1    *2440.00     94.00 PK    114.00     -20.00        1.27 H     303         93.27        0.73
  2    *2440.00     67.70 AV     94.00     -26.30        1.27 H     303         66.97        0.73
  3     4880.00     53.82 PK     74.00     -20.18        1.09 H     85          45.16        8.66
  4     4880.00     27.52 AV     54.00     -26.48        1.09 H     85          18.86        8.66
  5     7320.00     59.70 PK     74.00     -14.30        1.10 H     332         46.23        13.47
  6     7320.00     33.40 AV     54.00     -20.60        1.10 H     332         19.93        13.47
                    ANTENNA POLARITY & TEST DISTANCE: VERTICAL AT 3 M
                    EMISSION                           ANTENNA     TABLE        RAW      CORRECTION
        FREQ.                    LIMIT     MARGIN
 NO.                 LEVEL                              HEIGHT     ANGLE       VALUE       FACTOR
        (MHz)                  (dBuV/m)     (dB)
                    (dBuV/m)                              (m)     (Degree)     (dBuV)       (dB/m)
  1    *2440.00     90.95 PK    114.00     -23.05        3.86 V     244         90.22        0.73
  2    *2440.00     64.65 AV     94.00     -29.35        3.86 V     244         63.92        0.73
  3     4880.00     55.94 PK     74.00     -18.06        2.15 V     62          47.28        8.66
  4     4880.00     29.64 AV     54.00     -24.36        2.15 V     62          20.98        8.66
  5     7320.00     58.16 PK     74.00     -15.84        1.67 V     42          44.69        13.47
  6     7320.00     31.86 AV     54.00     -22.14        1.67 V     42          18.39        13.47
REMARKS:
   1. Emission Level(dBuV/m) = Raw Value(dBuV) + Correction Factor(dB/m)
   2. Correction Factor(dB/m) = Antenna Factor(dB/m) + Cable Factor(dB) – Pre-Amplifier Factor(dB)
   3. Margin value = Emission Level – Limit value
   4. The other emission levels were very low against the limit.
   5. " * ": Fundamental frequency.
   6. The average value of fundamental and harmonic frequency is: Average = Peak value + 20 log(Duty
      cycle) Where the duty factor is calculated from following formula:
      20 log(Duty cycle) = 20 log(0.046 ms / 0.954 ms) = -26.3 dB
      Please see page 18 for plotted duty.




Report No.: RF191016D01                     Page No. 16 / 24                       Report Format Version: 6.1.1


 CHANNEL                   TX Channel 77            DETECTOR                 Peak (PK)
 FREQUENCY RANGE           1GHz ~ 25GHz             FUNCTION                 Average (AV)


                  ANTENNA POLARITY & TEST DISTANCE: HORIZONTAL AT 3 M
                    EMISSION                           ANTENNA     TABLE        RAW      CORRECTION
        FREQ.                    LIMIT     MARGIN
 NO.                 LEVEL                              HEIGHT     ANGLE       VALUE       FACTOR
        (MHz)                  (dBuV/m)     (dB)
                    (dBuV/m)                              (m)     (Degree)     (dBuV)       (dB/m)
  1    *2479.00     94.02 PK    114.00     -19.98        1.53 H     299         93.10        0.92
  2    *2479.00     67.72 AV     94.00     -26.28        1.53 H     299         66.80        0.92
  3     2483.50     53.13 PK     74.00     -20.87        1.53 H     299         52.17        0.96
  4     2483.50     36.40 AV     54.00     -17.60        1.53 H     299         35.44        0.96
  5     4958.00     54.36 PK     74.00     -19.64        1.12 H     93          45.66        8.70
  6     4958.00     28.06 AV     54.00     -25.94        1.12 H     93          19.36        8.70
  7     7437.00     60.29 PK     74.00     -13.71        1.28 H     358         46.58        13.71
  8     7437.00     33.99 AV     54.00     -20.01        1.28 H     358         20.28        13.71
                    ANTENNA POLARITY & TEST DISTANCE: VERTICAL AT 3 M
                    EMISSION                           ANTENNA     TABLE        RAW      CORRECTION
        FREQ.                    LIMIT     MARGIN
 NO.                 LEVEL                              HEIGHT     ANGLE       VALUE       FACTOR
        (MHz)                  (dBuV/m)     (dB)
                    (dBuV/m)                              (m)     (Degree)     (dBuV)       (dB/m)
  1    *2479.00     90.96 PK    114.00     -23.04        3.94 V     251         90.04        0.92
  2    *2479.00     64.66 AV     94.00     -29.34        3.94 V     251         63.74        0.92
  3     2483.50     51.98 PK     74.00     -22.02        3.94 V     251         51.02        0.96
  4     2483.50     34.89 AV     54.00     -19.11        3.94 V     251         33.93        0.96
  5     4958.00     56.13 PK     74.00     -17.87        2.27 V     69          47.43        8.70
  6     4958.00     29.83 AV     54.00     -24.17        2.27 V     69          21.13        8.70
  7     7437.00     58.29 PK     74.00     -15.71        1.49 V     18          44.58        13.71
  8     7437.00     31.99 AV     54.00     -22.01        1.49 V     18          18.28        13.71
REMARKS:
   1. Emission Level(dBuV/m) = Raw Value(dBuV) + Correction Factor(dB/m)
   2. Correction Factor(dB/m) = Antenna Factor(dB/m) + Cable Factor(dB) – Pre-Amplifier Factor(dB)
   3. Margin value = Emission Level – Limit value
   4. The other emission levels were very low against the limit.
   5. " * ": Fundamental frequency.
   6. The average value of fundamental and harmonic frequency is: Average = Peak value + 20 log(Duty
      cycle) Where the duty factor is calculated from following formula:
      20 log(Duty cycle) = 20 log(0.046 ms / 0.954 ms) = -26.3 dB
      Please see page 18 for plotted duty.




Report No.: RF191016D01                     Page No. 17 / 24                       Report Format Version: 6.1.1


            Duty Cycle




                          20 log(Duty cycle) = 20 log(0.046 ms / 0.954 ms) = -26.3 dB




Report No.: RF191016D01                       Page No. 18 / 24                      Report Format Version: 6.1.1


BELOW 1GHz WORST-CASE DATA
 CHANNEL                   TX Channel 0             DETECTOR
                                                                             Quasi-Peak (QP)
 FREQUENCY RANGE           9kHz ~ 1GHz              FUNCTION


                  ANTENNA POLARITY & TEST DISTANCE: HORIZONTAL AT 3 M
                    EMISSION                           ANTENNA     TABLE        RAW      CORRECTION
        FREQ.                    LIMIT    MARGIN
 NO.                 LEVEL                              HEIGHT     ANGLE       VALUE       FACTOR
        (MHz)                  (dBuV/m)    (dB)
                    (dBuV/m)                              (m)     (Degree)     (dBuV)       (dB/m)
  1      42.27      22.69 QP    40.00      -17.31        1.33 H     302         30.24        -7.55
  2     145.53      20.08 QP    43.50      -23.42        1.67 H     96          26.97        -6.89
  3     411.55      24.91 QP    46.00      -21.09        2.14 H     169         27.72        -2.81
  4     530.86      27.46 QP    46.00      -18.54        1.89 H     37          27.58        -0.12
  5     657.15      30.11 QP    46.00      -15.89        1.77 H     165         27.43        2.68
  6     808.72      32.78 QP    46.00      -13.22        1.24 H     360         27.25        5.53
REMARKS:
   1. Emission Level(dBuV/m) = Raw Value(dBuV) + Correction Factor(dB/m)
   2. Correction Factor(dB/m) = Antenna Factor(dB/m) + Cable Factor(dB) – Pre-Amplifier Factor(dB)
   3. Margin value = Emission Level – Limit value
   4. The other emission levels were very low against the limit of frequency range 30MHz~1000MHz.
   5. The emission levels were very low against the limit of frequency range 9kHz~30MHz: the amplitude of
      spurious emissions attenuated more than 20 dB below the permissible value to be report.




Report No.: RF191016D01                     Page No. 19 / 24                       Report Format Version: 6.1.1


 CHANNEL                   TX Channel 0             DETECTOR
                                                                             Quasi-Peak (QP)
 FREQUENCY RANGE           9kHz ~ 1GHz              FUNCTION


                    ANTENNA POLARITY & TEST DISTANCE: VERTICAL AT 3 M
                    EMISSION                           ANTENNA     TABLE        RAW      CORRECTION
        FREQ.                    LIMIT    MARGIN
 NO.                 LEVEL                              HEIGHT     ANGLE       VALUE       FACTOR
        (MHz)                  (dBuV/m)    (dB)
                    (dBuV/m)                              (m)     (Degree)     (dBuV)       (dB/m)
  1      48.04      22.20 QP    40.00      -17.80        1.62 V     262         29.34        -7.14
  2     145.53      22.80 QP    43.50      -20.70        1.33 V     16          29.69        -6.89
  3     394.24      24.48 QP    46.00      -21.52        1.78 V     14          27.58        -3.10
  4     483.23      27.04 QP    46.00      -18.96        1.51 V     294         28.01        -0.97
  5     654.78      30.24 QP    46.00      -15.76        2.17 V     111         27.56        2.68
  6     807.75      32.92 QP    46.00      -13.08        1.96 V     109         27.41        5.51
REMARKS:
   1. Emission Level(dBuV/m) = Raw Value(dBuV) + Correction Factor(dB/m)
   2. Correction Factor(dB/m) = Antenna Factor(dB/m) + Cable Factor(dB) – Pre-Amplifier Factor(dB)
   3. Margin value = Emission Level – Limit value
   4. The other emission levels were very low against the limit of frequency range 30MHz~1000MHz.
   5. The emission levels were very low against the limit of frequency range 9kHz~30MHz: the amplitude of
      spurious emissions attenuated more than 20 dB below the permissible value to be report.




Report No.: RF191016D01                     Page No. 20 / 24                       Report Format Version: 6.1.1


4.2     Channel Bandwidth
4.2.1    Test Setup


                                                                Spectrum
            EUT
                                        Attenuator              Analyzer


4.2.2    Test Instruments

 Refer to section 4.1.2 to get information of above instrument.



4.2.3    Test Procedure

a. Check the calibration of the measuring instrument using either an internal calibrator or a known signal
   from an external generator.
b. Turn on the EUT and connect it to measurement instrument. Then set it to any one convenient frequency
   within its operating range. Set a reference level on the measuring instrument equal to the highest peak
   value.
c. Measure the frequency difference of two frequencies that were attenuated 20dB from the reference level.
   Record the frequency difference as the emission bandwidth.
d. Repeat above procedures until all frequencies measured were complete.



4.2.4    Deviation from Test Standard

 No deviation.



4.2.5    EUT Operating Condition
The software provided by client enabled the EUT to transmit and receive data at lowest, middle and highest
channel frequencies individually.




Report No.: RF191016D01                              Page No. 21 / 24               Report Format Version: 6.1.1


4.2.6   Test Results


             CHANNEL            FREQUENCY (MHz)          20dB BANDWIDTH (MHz)

                  0                     2402                      1.43
                  38                    2440                      2.03
                  77                    2479                      1.35

                          SPECTRUM PLOT of WORST VALUE




Report No.: RF191016D01          Page No. 22 / 24             Report Format Version: 6.1.1


5   Pictures of Test Arrangements


Please refer to the attached file (Test Setup Photo).




Report No.: RF191016D01                       Page No. 23 / 24   Report Format Version: 6.1.1


Appendix – Information of the Testing Laboratories

We, Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch, were founded in 1988 to
provide our best service in EMC, Radio, Telecom and Safety consultation. Our laboratories are FCC
recognized accredited test firms and accredited according to ISO/IEC 17025.

If you have any comments, please feel free to contact us at the following:

 Lin Kou EMC/RF Lab                                     Hsin Chu EMC/RF/Telecom Lab
 Tel: 886-2-26052180                                    Tel: 886-3-6668565
 Fax: 886-2-26051924                                    Fax: 886-3-6668323

 Hwa Ya EMC/RF/Safety Lab
 Tel: 886-3-3183232
 Fax: 886-3-3270892

 Email: service.adt@tw.bureauveritas.com
 Web Site: www.bureauveritas-adt.com

The address and road map of all our labs can be found in our web site also.



--- END ---




Report No.: RF191016D01                        Page No. 24 / 24                  Report Format Version: 6.1.1



Document Created: 2019-11-05 11:30:33
Document Modified: 2019-11-05 11:30:33

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC