Test report (DTS-BT LE)

FCC ID: E8HKC-1907

Test Report

Download: PDF
FCCID_4503838

                                                               FCC Test Report

                       Report No.: RF191016D01-1

                            FCC ID: E8HKC-1907

                       Test Model: KB7120Wc

                 Received Date: Oct. 16, 2019

                         Test Date: Oct. 22 to 30, 2019

                     Issued Date: Nov. 1, 2019


                         Applicant: Chicony Electronics Co., Ltd.

                          Address: No.69, Sec. 2, Guangfu Rd., Sanchong Dist., New Taipei City 241,
                                   Taiwan(R.O.C.)

                        Issued By: Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch
                                   Lin Kou Laboratories
                    Lab Address: No. 47-2, 14th Ling, Chia Pau Vil., Lin Kou Dist., New Taipei City, Taiwan

       FCC Registration /
      Designation Number: 198487 / TW2021




This report is for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted
only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this
report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product
unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you
provided to us. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence, provided,
however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time
shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Unless specific
mention, the uncertainty of measurement has been explicitly taken into account to declare the compliance or non-compliance to the specification. The report
must not be used by the client to claim product certification, approval, or endorsement by TAF or any government agencies.

Report No.: RF191016D01-1                                            Page No. 1 / 31                                            Report Format Version: 6.1.1


                                                                   Table of Contents
Release Control Record .................................................................................................................................. 4
1         Certificate of Conformity...................................................................................................................... 5
2         Summary of Test Results ..................................................................................................................... 6
    2.1      Measurement Uncertainty ................................................................................................................... 6
    2.2      Modification Record ............................................................................................................................ 6
3         General Information .............................................................................................................................. 7
    3.1      General Description of EUT ................................................................................................................ 7
    3.2      Description of Test Modes ................................................................................................................... 8
    3.2.1    Test Mode Applicability and Tested Channel Detail ............................................................................. 9
    3.3      Duty cycle of test signal .................................................................................................................... 10
    3.4      Description of Support Units ............................................................................................................. 10
    3.4.1    Configuration of System under Test .................................................................................................. 10
    3.5      General Description of Applied Standards ......................................................................................... 11
4         Test Types and Results ...................................................................................................................... 12
    4.1      Radiated Emission and Bandedge Measurement............................................................................. 12
    4.1.1    Limits of Radiated Emission and Bandedge Measurement .............................................................. 12
    4.1.2    Test Instruments ................................................................................................................................ 13
    4.1.3    Test Procedures................................................................................................................................. 14
    4.1.4    Deviation from Test Standard ............................................................................................................ 14
    4.1.5    Test Setup .......................................................................................................................................... 15
    4.1.6    EUT Operating Conditions................................................................................................................. 16
    4.1.7    Test Results ....................................................................................................................................... 17
    4.2      6dB Bandwidth Measurement ........................................................................................................... 22
    4.2.1    Limits of 6dB Bandwidth Measurement ............................................................................................. 22
    4.2.2    Test Setup .......................................................................................................................................... 22
    4.2.3    Test Instruments ................................................................................................................................ 22
    4.2.4    Test Procedure .................................................................................................................................. 22
    4.2.5    Deviation fromTest Standard ............................................................................................................. 22
    4.2.6    EUT Operating Conditions................................................................................................................. 22
    4.2.7    Test Result ......................................................................................................................................... 23
    4.3      Conducted Output Power Measurement........................................................................................... 24
    4.3.1    Limits OF Conducted Output Power Measurement .......................................................................... 24
    4.3.2    Test Setup .......................................................................................................................................... 24
    4.3.3    Test Instruments ................................................................................................................................ 24
    4.3.4    Test Procedures................................................................................................................................. 24
    4.3.5    Deviation from Test Standard ............................................................................................................ 24
    4.3.6    EUT Operating Conditions................................................................................................................. 24
    4.3.7    Test Results ....................................................................................................................................... 25
    4.4      Power Spectral Density Measurement .............................................................................................. 26
    4.4.1    Limits of Power Spectral Density Measurement ................................................................................ 26
    4.4.2    Test Setup .......................................................................................................................................... 26
    4.4.3    Test Instruments ................................................................................................................................ 26
    4.4.4    Test Procedure .................................................................................................................................. 26
    4.4.5    Deviation from Test Standard ............................................................................................................ 26
    4.4.6    EUT Operating Condition .................................................................................................................. 26
    4.4.7    Test Results ....................................................................................................................................... 27
    4.5      Conducted Out of Band Emission Measurement .............................................................................. 28

Report No.: RF191016D01-1                                            Page No. 2 / 31                                             Report Format Version: 6.1.1


    4.5.1   Limits of Conducted Out of Band Emission Measurement................................................................ 28
    4.5.2   Test Setup .......................................................................................................................................... 28
    4.5.3   Test Instruments ................................................................................................................................ 28
    4.5.4   Test Procedure .................................................................................................................................. 28
    4.5.5   Deviation from Test Standard ............................................................................................................ 28
    4.5.6   EUT Operating Condition .................................................................................................................. 28
    4.5.7   Test Results ....................................................................................................................................... 29
5       Pictures of Test Arrangements .......................................................................................................... 30
Appendix – Information of the Testing Laboratories ................................................................................. 31




Report No.: RF191016D01-1                                           Page No. 3 / 31                                             Report Format Version: 6.1.1


                                           Release Control Record


Issue No.              Description                                         Date Issued
RF191016D01-1          Original release.                                   Nov. 1, 2019




Report No.: RF191016D01-1                     Page No. 4 / 31       Report Format Version: 6.1.1


1    Certificate of Conformity


            Product: Wireless Keyboard

              Brand: DELL

        Test Model: KB7120Wc

    Sample Status: Engineering sample

          Applicant: Chicony Electronics Co., Ltd.

          Test Date: Oct. 22 to 30, 2019

         Standards: 47 CFR FCC Part 15, Subpart C (Section 15.247)
                        ANSI C63.10: 2013



The above equipment has been tested by Bureau Veritas Consumer Products Services (H.K.) Ltd.,
Taoyuan Branch, and found compliance with the requirement of the above standards. The test record, data
evaluation & Equipment Under Test (EUT) configurations represented herein are true and accurate accounts
of the measurements of the sample’s RF characteristics under the conditions specified in this report.




     Prepared by :                                                      , Date:          Nov. 1, 2019
                               Annie Chang / Senior Specialist




     Approved by :                                                      , Date:          Nov. 1, 2019
                            Rex Lai / Associate Technical Manager




Report No.: RF191016D01-1                     Page No. 5 / 31                         Report Format Version: 6.1.1


2      Summary of Test Results


                               47 CFR FCC Part 15, Subpart C (SECTION 15.247)

        FCC
                                Test Item                  Result                     Remarks
       Clause
       15.207      AC Power Conducted Emission                  N/A    Power supply is 3Vdc from batteries
                   Radiated Emissions & Band Edge                      Meet the requirement of limit.
    15.205 & 209
                   Measurement                             PASS        Minimum passing margin is -4.57dB at
     & 15.247(d)
                                                                       7320.00 MHz.
      15.247(d)    Antenna Port Emission                   PASS        Meet the requirement of limit.
    15.247(a)(2)   6dB bandwidth                           PASS        Meet the requirement of limit.
      15.247(b)    Conducted power                         PASS        Meet the requirement of limit.
      15.247(e)    Power Spectral Density                  PASS        Meet the requirement of limit.
       15.203      Antenna Requirement                     PASS        No antenna connector is used.
Note: Determining compliance based on the results of the compliance measurement, not taking into account
      measurement instrumentation uncertainty.



2.1      Measurement Uncertainty
Where relevant, the following measurement uncertainty levels have been estimated for tests performed on the
EUT as specified in CISPR 16-4-2:
                                                                                       Expanded Uncertainty
                    Measurement                                  Frequency
                                                                                            (k=2) (±)
                                                            9kHz ~ 30MHz                     2.38 dB
           Radiated Emissions up to 1 GHz
                                                          30MHz ~ 1000MHz                    5.43 dB
          Radiated Emissions above 1 GHz                     Above 1GHz                      5.42 dB




2.2      Modification Record
There were no modifications required for compliance.




Report No.: RF191016D01-1                     Page No. 6 / 31                           Report Format Version: 6.1.1


3     General Information
3.1     General Description of EUT

 Product                    Wireless Keyboard
 Brand                      DELL
 Test Model                 KB7120Wc
 Status of EUT              Engineering sample
 Power Supply Rating        3.0Vdc from batteries
 Modulation Type            GFSK
 Transfer Rate              Up to 1Mbps
 Operating Frequency        2402MHz ~ 2480MHz
 Number of Channel          40
 Output Power               0.968mW
 Antenna Type               PCB antenna with -0.81dBi gain
 Antenna Connector          N/A
 Accessory Device           N/A
 Data Cable Supplied        N/A
Note:
1. Bluetooth & GFSK technologies can not transmit at same time.
2. The above EUT information is declared by manufacturer and for more detailed features description,
   please refer to the manufacturer's specifications or user's manual.




Report No.: RF191016D01-1                       Page No. 7 / 31                    Report Format Version: 6.1.1


3.2   Description of Test Modes

40 channels are provided to this EUT:
                 FREQ.                  FREQ.                   FREQ.                   FREQ.
CHANNEL                     CHANNEL                 CHANNEL             CHANNEL
                 (MHz)                  (MHz)                   (MHz)                   (MHz)
      0           2402         10        2422              20    2442     30             2462
      1           2404         11        2424              21    2444     31             2464
      2           2406         12        2426              22    2446     32             2466
      3           2408         13        2428              23    2448     33             2468
      4           2410         14        2430              24    2450     34             2470
      5           2412         15        2432              25    2452     35             2472
      6           2414         16        2434              26    2454     36             2474
      7           2416         17        2436              27    2456     37             2476
      8           2418         18        2438              28    2458     38             2478
      9           2420         19        2440              29    2460     39             2480




Report No.: RF191016D01-1                Page No. 8 / 31                 Report Format Version: 6.1.1


3.2.1        Test Mode Applicability and Tested Channel Detail

EUT Configure                          Applicable To
                                                                                            Description
    Mode
                     RE1G      RE<1G             PLC       APCM

         -              √          √              Note         √       -
Where         RE1G: Radiated Emission above 1GHz            RE<1G: Radiated Emission below 1GHz
              PLC: Power Line Conducted Emission             APCM: Antenna Port Conducted Measurement
NOTE: No need to concern of Conducted Emission due to the EUT is powered by batteries.




 Radiated Emission Test (Above 1GHz):

        Pre-Scan has been conducted to determine the worst-case mode from all possible combinations
        between available modulations, data rates and antenna ports (if EUT with antenna diversity
        architecture).
        Following channel(s) was (were) selected for the final test as listed below.
   EUT Configuure Mode         Available Channel           Tested Channel         Modulation Type         Data Rate (Mbps)

                -                       0 to 39                0, 19, 39                 GFSK                     1



 Radiated Emission Test (Below 1GHz):

        Pre-Scan has been conducted to determine the worst-case mode from all possible combinations
        between available modulations, data rates and antenna ports (if EUT with antenna diversity
        architecture).
        Following channel(s) was (were) selected for the final test as listed below.
   EUT Configuure Mode         Available Channel           Tested Channel         Modulation Type         Data Rate (Mbps)

                -                       0 to 39                    0                     GFSK                     1



 Antenna Port Conducted Measurement:

        This item includes all test value of each mode, but only includes spectrum plot of worst value of each
        mode.
        Pre-Scan has been conducted to determine the worst-case mode from all possible combinations
        between available modulations, data rates and antenna ports (if EUT with antenna diversity
        architecture).
        Following channel(s) was (were) selected for the final test as listed below.
  EUT Configuure Mode         Available Channel            Tested Channel         Modulation Type         Data Rate (Mbps)

                -                      0 to 39                0, 19, 39                  GFSK                     1



 Test Condition:

        Applicable To        Environmental Conditions               Input Power                      Tested By
             RE1G               23deg. C, 78%RH                       3.0Vdc                        Dalen Dai
             RE<1G               23deg. C, 78%RH                       3.0Vdc                        Dalen Dai
              APCM               25deg. C, 76%RH                       3.0Vdc                        Saxon Lee




Report No.: RF191016D01-1                                Page No. 9 / 31                            Report Format Version: 6.1.1


3.3      Duty cycle of test signal

Duty cycle of test signal is < 98 %, duty factor shall be considered.
Duty cycle = 0.391/0.626 = 0.625, Duty factor = 10 * log( 1/0.625) = 2.04




3.4      Description of Support Units

The EUT has been tested as an independent unit together without other necessary accessories or support
units.



3.4.1     Configuration of System under Test




                                                           EUT




                                               (Powered from batteries)




Report No.: RF191016D01-1                       Page No. 10 / 31                  Report Format Version: 6.1.1


3.5   General Description of Applied Standards


 The EUT is a RF Product. According to the specifications of the manufacturer, it must comply with the
 requirements of the following standards:

 FCC Part 15, Subpart C (15.247)
 KDB 558074 D01 15.247 Meas Guidance v05r02
 ANSI C63.10-2013


 All test items have been performed and recorded as per the above standards.




Report No.: RF191016D01-1                    Page No. 11 / 31                        Report Format Version: 6.1.1


4       Test Types and Results
4.1     Radiated Emission and Bandedge Measurement
4.1.1    Limits of Radiated Emission and Bandedge Measurement

Radiated emissions which fall in the restricted bands must comply with the radiated emission limits
specified as below table. Other emissions shall be at least 20dB below the highest level of the desired
power:

            Frequencies                         Field Strength                  Measurement Distance
               (MHz)                          (microvolts/meter)                      (meters)

            0.009 ~ 0.490                       2400/F(kHz)                               300
            0.490 ~ 1.705                       24000/F(kHz)                              30
            1.705 ~ 30.0                              30                                  30
               30 ~ 88                               100                                   3
              88 ~ 216                               150                                   3
              216 ~ 960                              200                                   3
             Above 960                               500                                   3
NOTE:
1.  The lower limit shall apply at the transition frequencies.
2.  Emission level (dBuV/m) = 20 log Emission level (uV/m).
3.  For frequencies above 1000MHz, the field strength limits are based on average detector, however, the
    peak field strength of any emission shall not exceed the maximum permitted average limits, specified
    above by more than 20dB under any condition of modulation.




Report No.: RF191016D01-1                     Page No. 12 / 31                        Report Format Version: 6.1.1


4.1.2   Test Instruments

    DESCRIPTION &                                                          CALIBRATED CALIBRATED
                                MODEL NO.                 SERIAL NO.
    MANUFACTURER                                                                DATE             UNTIL
HP Preamplifier                     8447D                 2432A03504       Feb. 20, 2019     Feb. 19, 2020
HP Preamplifier                      8449B                3008A01201       Feb. 21, 2019     Feb. 20, 2020
MITEQ Preamplifier         AMF-6F-260400-33-8P              892164         Feb. 20, 2019     Feb. 19, 2020
Agilent
                                   N9038A                 MY51210129       Mar. 05, 2019     Mar. 04, 2020
TEST RECEIVER
Schwarzbeck Antenna              VULB 9168                    139          Nov. 26, 2018     Nov. 25, 2019
Schwarzbeck Antenna              VHBA 9123                    480           Jun. 3, 2019      Jun. 2, 2021
Schwarzbeck Horn
                                 BBHA-9170                    212          Nov. 25, 2018     Nov. 24, 2019
Antenna
Schwarzbeck Horn
                               BBHA 9120-D1                   D130         Nov. 25, 2018     Nov. 24, 2019
Antenna
ADT. Turn Table                      TT100                    0306                NA                NA
ADT. Tower                           AT100                    0306                NA                NA
Software                    Radiated_V7.6.15.9.5               NA                 NA                NA
SUHNER RF cable
                                    SF102                Cable-CH6-01       Jul. 10, 2019      Jul. 9, 2020
With 4dB PAD
SUHNER RF cable
                                    SF102              Cable-CH8-3.6m       Jul. 10, 2019      Jul. 9, 2020
With 3/4dB PAD
KEYSIGHT MIMO
Powermeasurement Test              U2021XA               U2021XA-001       Jun. 11, 2019     Jun. 10, 2020
set
KEYSIGHT
                                   N9030A                 MY54490260        Jul. 30, 2019     Jul. 29, 2020
Spectrum Analyzer
Loop Antenna EMCI                   LPA600                    270          Aug. 23, 2019    Aug. 22, 2021
EMCO Horn Antenna                     3115                 00028257        Nov. 25, 2018     Nov. 24, 2019
Highpass filter
                             WHK 3.1/18G-10SS                 SN 8                NA                NA
Wainwright Instruments
ROHDE & SCHWARZ
                                    FSV40                    101042        Sep. 23, 2019     Sep. 22, 2020
Spectrum Analyzer
Anritsu
                                  MA2411B                   0738404        Apr. 16, 2019     Apr. 15, 2020
Power Sensor
Anritsu
                                   ML2495A                  0842014        Apr. 16, 2019     Apr. 15, 2020
Power Meter
 NOTE: 1. The calibration interval of the above test instruments is 12/24 months. And the calibrations are
            traceable to NML/ROC and NIST/USA.
        2. The horn antenna and HP preamplifier (model: 8449B) are used only for the measurement of
            emission frequency above 1GHz if tested.
        3. The test was performed in Chamber No. 6.




Report No.: RF191016D01-1                     Page No. 13 / 31                       Report Format Version: 6.1.1


4.1.3      Test Procedures

For Radiated emission below 30MHz
 a. The EUT was placed on the top of a rotating table 0.8 meters above the ground at a 3 meter chamber
    room. The table was rotated 360 degrees to determine the position of the highest radiation.
 b. The EUT was set 3 meters away from the interference-receiving antenna, which was mounted on the top
    of a variable-height antenna tower.
 c. Parallel, perpendicular, and ground-parallel orientations of the antenna are set to make the
    measurement.
     d. For each suspected emission, the EUT was arranged to its worst case and the rotatable table was turned
        from 0 degrees to 360 degrees to find the maximum reading.
     e. The test-receiver system was set to Quasi-Peak Detect Function and Specified Bandwidth with Maximum
        Hold Mode.
NOTE: The resolution bandwidth and video bandwidth of test receiver/spectrum analyzer is 9kHz at
      frequency below 30MHz.

For Radiated emission above 30MHz
a. The EUT was placed on the top of a rotating table 0.8 meters (for 30MHz ~ 1GHz) / 1.5 meters (for above
    1GHz) above the ground at 3 meter chamber room for test. The table was rotated 360 degrees to
    determine the position of the highest radiation.
b.      The EUT was set 3 meters away from the interference-receiving antenna, which was mounted on the top
        of a variable-height antenna tower.
c.      The height of antenna is varied from one meter to four meters above the ground to determine the
        maximum value of the field strength. Both horizontal and vertical polarizations of the antenna are set to
        make the measurement.
d.      For each suspected emission, the EUT was arranged to its worst case and then the antenna was tuned
        to heights from 1 meter to 4 meters and the rotatable table was turned from 0 degrees to 360 degrees to
        find the maximum reading.
e.      The test-receiver system was set to quasi-peak detect function and specified bandwidth with maximum
        hold mode when the test frequency is below 1 GHz.
f.      The test-receiver system was set to peak and average detect function and specified bandwidth with
        maximum hold mode when the test frequency is above 1 GHz. If the peak reading value also meets
        average limit, measurement with the average detector is unnecessary.
Note:
1. The resolution bandwidth and video bandwidth of test receiver/spectrum analyzer is 120kHz for
    Quasi-peak detection (QP) at frequency below 1GHz.
2.      The resolution bandwidth of test receiver/spectrum analyzer is 1 MHz and the video bandwidth is 3 MHz
        for Peak detection (PK) at frequency above 1GHz.
3.      The resolution bandwidth of test receiver/spectrum analyzer is 1MHz and the video bandwidth is ≥ 1/T
        (Duty cycle < 98%) or 10Hz (Duty cycle ≥ 98%) for Peak detection at frequency above 1GHz.
4.      All modes of operation were investigated and the worst-case emissions are reported.


4.1.4      Deviation from Test Standard
     No deviation.




Report No.: RF191016D01-1                         Page No. 14 / 31                        Report Format Version: 6.1.1


4.1.5   Test Setup

 For Radiated emission below 30MHz


                                                                    1m
            EUT&                       3m
            Support Units

                              Turn Table

               80cm


                                     Ground Plane
                                     Test Receiver




 For Radiated emission 30MHz to 1GHz

                                                       Ant. Tower
                                                                     1-4m
                                                                     Variable
              EUT&                         3m
              Support Units

                                  Turn Table

                  80cm


                                       Ground Plane

                                       Test Receiver




Report No.: RF191016D01-1               Page No. 15 / 31                 Report Format Version: 6.1.1


 For Radiated emission above 1GHz



                                                  Ant. Tower            1-4m
                                                                        Variable
 EUT&                               3m
 Support Units

                            Turn Table
                                         Absorber

    150cm


                                  Ground Plane
                                  Test Receiver




 For the actual test configuration, please refer to the attached file (Test Setup Photo).




4.1.6   EUT Operating Conditions

Set the EUT under transmission condition continuously at specific channel frequency.




Report No.: RF191016D01-1                       Page No. 16 / 31                            Report Format Version: 6.1.1


4.1.7    Test Results

ABOVE 1GHz DATA
CHANNEL                     TX Channel 0            DETECTOR                 Peak (PK)
FREQUENCY RANGE             1GHz ~ 25GHz            FUNCTION                 Average (AV)


                   ANTENNA POLARITY & TEST DISTANCE: HORIZONTAL AT 3 M
                   EMISSION                            ANTENNA     TABLE        RAW      CORRECTION
         FREQ.                    LIMIT    MARGIN
NO.                 LEVEL                               HEIGHT     ANGLE       VALUE       FACTOR
         (MHz)                  (dBuV/m)    (dB)
                   (dBuV/m)                               (m)     (Degree)     (dBuV)       (dB/m)
  1      2390.00    48.97 PK     74.00     -25.03        1.43 H     304         48.39        0.58
  2      2390.00    42.17 AV     54.00     -11.83        1.43 H     304         41.59        0.58
  3     *2402.00    94.22 PK                             1.43 H     304         93.61        0.61
  4     *2402.00    93.29 AV                             1.43 H     304         92.68         0.61
  5      4804.00    53.39 PK     74.00     -20.61        1.07 H     114         45.13        8.26
  6      4804.00    44.29 AV     54.00      -9.71        1.07 H     114         36.03        8.26
  7     #7206.00    59.27 PK     74.00     -14.73        1.19 H     353         46.13        13.14
  8     #7206.00    48.96 AV     54.00      -5.04        1.19 H     353         35.82        13.14
                    ANTENNA POLARITY & TEST DISTANCE: VERTICAL AT 3 M
                   EMISSION                            ANTENNA     TABLE        RAW      CORRECTION
         FREQ.                    LIMIT    MARGIN
NO.                 LEVEL                               HEIGHT     ANGLE       VALUE       FACTOR
         (MHz)                  (dBuV/m)    (dB)
                   (dBuV/m)                               (m)     (Degree)     (dBuV)       (dB/m)
  1      2390.00    47.33 PK     74.00     -26.67        3.69 V     217         46.75        0.58
  2      2390.00    39.46 AV     54.00     -14.54        3.69 V     217         38.88        0.58
  3     *2402.00    92.44 PK                             3.69 V     217         91.83        0.61
  4     *2402.00    91.52 AV                             3.69 V     217         90.91         0.61
  5      4804.00    55.51 PK     74.00     -18.49        4.00 V     82          47.25        8.26
  6      4804.00    46.29 AV     54.00      -7.71        4.00 V     82          38.03        8.26
  7     #7206.00    57.66 PK     74.00     -16.34        1.62 V     29          44.52        13.14
  8     #7206.00    47.53 AV     54.00      -6.47        1.62 V     29          34.39        13.14
REMARKS:
   1. Emission Level(dBuV/m) = Raw Value(dBuV) + Correction Factor(dB/m)
   2. Correction Factor(dB/m) = Antenna Factor(dB/m) + Cable Factor(dB) – Pre-Amplifier Factor(dB)
   3. Margin value = Emission Level – Limit value
   4. The other emission levels were very low against the limit.
   5. " * ": Fundamental frequency.
   6. " # ": The radiated frequency is out of the restricted band.




Report No.: RF191016D01-1                    Page No. 17 / 31                       Report Format Version: 6.1.1


CHANNEL                     TX Channel 19            DETECTOR                 Peak (PK)
FREQUENCY RANGE             1GHz ~ 25GHz             FUNCTION                 Average (AV)


                  ANTENNA POLARITY & TEST DISTANCE: HORIZONTAL AT 3 M
                   EMISSION                             ANTENNA     TABLE        RAW      CORRECTION
        FREQ.                     LIMIT     MARGIN
NO.                 LEVEL                                HEIGHT     ANGLE       VALUE       FACTOR
        (MHz)                   (dBuV/m)     (dB)
                   (dBuV/m)                                (m)     (Degree)     (dBuV)       (dB/m)
  1    *2440.00     94.28 PK                              1.51 H     301         93.55        0.73
  2    *2440.00     93.35 AV                              1.51 H     301         92.62         0.73
  3     4880.00     53.77 PK     74.00      -20.23        1.14 H     108         45.11        8.66
  4     4880.00     44.65 AV     54.00       -9.35        1.14 H     108         35.99        8.66
  5     7320.00     59.74 PK     74.00      -14.26        1.21 H     340         46.27        13.47
  6     7320.00     49.43 AV     54.00       -4.57        1.21 H     340         35.96        13.47
                    ANTENNA POLARITY & TEST DISTANCE: VERTICAL AT 3 M
                   EMISSION                             ANTENNA     TABLE        RAW      CORRECTION
        FREQ.                     LIMIT     MARGIN
NO.                 LEVEL                                HEIGHT     ANGLE       VALUE       FACTOR
        (MHz)                   (dBuV/m)     (dB)
                   (dBuV/m)                                (m)     (Degree)     (dBuV)       (dB/m)
  1    *2440.00     92.39 PK                              3.70 V     221         91.66        0.73
  2    *2440.00     91.46 AV                              3.70 V     221         90.73         0.73
  3     4880.00     55.69 PK     74.00      -18.31        3.93 V     77          47.03        8.66
  4     4880.00     46.55 AV     54.00       -7.45        3.93 V     77          37.89        8.66
  5     7320.00     57.68 PK     74.00      -16.32        1.58 V     19          44.21        13.47
  6     7320.00     47.41 AV     54.00       -6.59        1.58 V     19          33.94        13.47
REMARKS:
   1. Emission Level(dBuV/m) = Raw Value(dBuV) + Correction Factor(dB/m)
   2. Correction Factor(dB/m) = Antenna Factor(dB/m) + Cable Factor(dB) – Pre-Amplifier Factor(dB)
   3. Margin value = Emission Level – Limit value
   4. The other emission levels were very low against the limit.
   5. " * ": Fundamental frequency.




Report No.: RF191016D01-1                     Page No. 18 / 31                       Report Format Version: 6.1.1


CHANNEL                     TX Channel 39            DETECTOR                 Peak (PK)
FREQUENCY RANGE             1GHz ~ 25GHz             FUNCTION                 Average (AV)


                  ANTENNA POLARITY & TEST DISTANCE: HORIZONTAL AT 3 M
                   EMISSION                             ANTENNA     TABLE        RAW      CORRECTION
        FREQ.                     LIMIT     MARGIN
NO.                 LEVEL                                HEIGHT     ANGLE       VALUE       FACTOR
        (MHz)                   (dBuV/m)     (dB)
                   (dBuV/m)                                (m)     (Degree)     (dBuV)       (dB/m)
  1    *2480.00     94.11 PK                              1.53 H     300         93.19        0.92
  2    *2480.00     93.19 AV                              1.53 H     300         92.27        0.92
  3     2483.50     53.73 PK     74.00      -20.27        1.53 H     300         52.77        0.96
  4     2483.50     45.11 AV     54.00       -8.89        1.53 H     300         44.15        0.96
  5     4960.00     53.78 PK     74.00      -20.22        1.09 H     102         45.09        8.69
  6     4960.00     44.64 AV     54.00       -9.36        1.09 H     102         35.95        8.69
  7     7440.00     59.80 PK     74.00      -14.20        1.14 H     349         46.08        13.72
  8     7440.00     49.37 AV     54.00       -4.63        1.14 H     349         35.65        13.72
                    ANTENNA POLARITY & TEST DISTANCE: VERTICAL AT 3 M
                   EMISSION                             ANTENNA     TABLE        RAW      CORRECTION
        FREQ.                     LIMIT     MARGIN
NO.                 LEVEL                                HEIGHT     ANGLE       VALUE       FACTOR
        (MHz)                   (dBuV/m)     (dB)
                   (dBuV/m)                                (m)     (Degree)     (dBuV)       (dB/m)
  1    *2480.00     92.12 PK                              3.71 V     219         91.20        0.92
  2    *2480.00     91.19 AV                              3.71 V     219         90.27         0.92
  3     2483.50     52.21 PK     74.00      -21.79        3.71 V     219         51.25        0.96
  4     2483.50     48.09 AV     54.00       -5.91        3.71 V     219         47.13        0.96
  5     4960.00     46.63 PK     74.00      -27.37        3.88 V     80          37.94        8.69
  6     4960.00     39.67 AV     54.00      -14.33        3.88 V     80          30.98        8.69
  7     7440.00     58.03 PK     74.00      -15.97        1.54 V     20          44.31        13.72
  8     7440.00     47.80 AV     54.00       -6.20        1.54 V     20          34.08        13.72
REMARKS:
   1. Emission Level(dBuV/m) = Raw Value(dBuV) + Correction Factor(dB/m)
   2. Correction Factor(dB/m) = Antenna Factor(dB/m) + Cable Factor(dB) – Pre-Amplifier Factor(dB)
   3. Margin value = Emission Level – Limit value
   4. The other emission levels were very low against the limit.
   5. " * ": Fundamental frequency.




Report No.: RF191016D01-1                     Page No. 19 / 31                       Report Format Version: 6.1.1


BELOW 1GHz WORST-CASE DATA
CHANNEL                     TX Channel 0            DETECTOR
                                                                             Quasi-Peak (QP)
FREQUENCY RANGE             9kHz ~ 1GHz             FUNCTION


                  ANTENNA POLARITY & TEST DISTANCE: HORIZONTAL AT 3 M
                   EMISSION                            ANTENNA     TABLE        RAW      CORRECTION
        FREQ.                     LIMIT    MARGIN
NO.                 LEVEL                               HEIGHT     ANGLE       VALUE       FACTOR
        (MHz)                   (dBuV/m)    (dB)
                   (dBuV/m)                               (m)     (Degree)     (dBuV)       (dB/m)
  1      42.03      23.17 QP     40.00     -16.83        1.95 H     140         30.74        -7.57
  2     161.39      19.95 QP     43.50     -23.55        1.61 H     223         26.58        -6.63
  3     376.05      24.64 QP     46.00     -21.36        1.80 H     58          28.12        -3.48
  4     462.13      26.44 QP     46.00     -19.56        1.17 H     360         27.78        -1.34
  5     610.40      29.02 QP     46.00     -16.98        1.83 H     274         27.03        1.99
  6     811.48      32.93 QP     46.00     -13.07        1.59 H     233         27.35        5.58
REMARKS:
   1. Emission Level(dBuV/m) = Raw Value(dBuV) + Correction Factor(dB/m)
   2. Correction Factor(dB/m) = Antenna Factor(dB/m) + Cable Factor(dB) – Pre-Amplifier Factor(dB)
   3. Margin value = Emission Level – Limit value
   4. The other emission levels were very low against the limit of frequency range 30MHz~1000MHz.
   5. The emission levels were very low against the limit of frequency range 9kHz~30MHz: the amplitude of
      spurious emissions attenuated more than 20 dB below the permissible value to be report.




Report No.: RF191016D01-1                    Page No. 20 / 31                       Report Format Version: 6.1.1


CHANNEL                     TX Channel 0            DETECTOR
                                                                             Quasi-Peak (QP)
FREQUENCY RANGE             9kHz ~ 1GHz             FUNCTION


                    ANTENNA POLARITY & TEST DISTANCE: VERTICAL AT 3 M
                   EMISSION                            ANTENNA     TABLE        RAW      CORRECTION
        FREQ.                     LIMIT    MARGIN
NO.                 LEVEL                               HEIGHT     ANGLE       VALUE       FACTOR
        (MHz)                   (dBuV/m)    (dB)
                   (dBuV/m)                               (m)     (Degree)     (dBuV)       (dB/m)
  1      47.95      22.05 QP     40.00     -17.95        1.56 V     318         29.20        -7.15
  2     149.79      21.01 QP     43.50     -22.49        1.14 V     76          27.77        -6.76
  3     312.42      22.72 QP     46.00     -23.28        1.73 V     28          27.27        -4.55
  4     456.56      26.64 QP     46.00     -19.36        1.52 V     268         28.07        -1.43
  5     615.30      29.04 QP     46.00     -16.96        2.09 V     199         26.90        2.14
  6     826.52      33.10 QP     46.00     -12.90        1.88 V      0          27.26        5.84
REMARKS:
   1. Emission Level(dBuV/m) = Raw Value(dBuV) + Correction Factor(dB/m)
   2. Correction Factor(dB/m) = Antenna Factor(dB/m) + Cable Factor(dB) – Pre-Amplifier Factor(dB)
   3. Margin value = Emission Level – Limit value
   4. The other emission levels were very low against the limit of frequency range 30MHz~1000MHz.
   5. The emission levels were very low against the limit of frequency range 9kHz~30MHz: the amplitude of
      spurious emissions attenuated more than 20 dB below the permissible value to be report.




Report No.: RF191016D01-1                    Page No. 21 / 31                       Report Format Version: 6.1.1


4.2     6dB Bandwidth Measurement
4.2.1     Limits of 6dB Bandwidth Measurement

 The minimum of 6dB Bandwidth Measurement is 0.5 MHz.



4.2.2     Test Setup



                                                            Spectrum
            EUT
                                     Attenuator             Analyzer



4.2.3     Test Instruments

 Refer to section 4.1.2 to get information of above instrument.



4.2.4     Test Procedure

 a.     Set resolution bandwidth (RBW) = 100kHz
 b.     Set the video bandwidth (VBW) ≥ 3 x RBW, Detector = Peak.
 c.     Trace mode = max hold.
 d.     Sweep = auto couple.
 e.     Measure the maximum width of the emission that is constrained by the frequencies associated with the
        two amplitude points (upper and lower) that are attenuated by 6 dB relative to the maximum level
        measured in the fundamental emission


4.2.5     Deviation fromTest Standard

 No deviation.



4.2.6     EUT Operating Conditions

 The software provided by client to enable the EUT under transmission condition continuously at lowest,
 middle and highest channel frequencies individually.




Report No.: RF191016D01-1                         Page No. 22 / 31                    Report Format Version: 6.1.1


4.2.7    Test Result


                                              6dB Bandwidth      Minimum Limit
        Channel             Frequency (MHz)                                               Pass / Fail
                                                  (MHz)              (MHz)

          0                      2402                0.71             0.5                    Pass

          19                     2440                0.71             0.5                    Pass

          39                     2480                0.71             0.5                    Pass



                                     SPECTRUM PLOT OF WORST VALUE
                                                 CH 0




Report No.: RF191016D01-1                     Page No. 23 / 31                   Report Format Version: 6.1.1


4.3     Conducted Output Power Measurement
4.3.1    Limits OF Conducted Output Power Measurement

 For systems using digital modulation in the 2400–2483.5 MHz bands: 1 Watt (30dBm)


4.3.2    Test Setup




           EUT                               Power Sensor                 Power Meter
                            Attenuator




4.3.3    Test Instruments

 Refer to section 4.1.2 to get information of above instrument.




4.3.4    Test Procedures

 A peak power sensor was used on the output port of the EUT. A power meter was used to read the response
 of the peak power sensor. Record the power level.

 Average power sensor was used to perform output power measurement, trigger and gating function of wide
 band power meter is enabled to measure max output power of TX on burst. Duty factor is not added to
 measured value.




4.3.5    Deviation from Test Standard

 No deviation.




4.3.6    EUT Operating Conditions

 Same as Item 4.2.6.




Report No.: RF191016D01-1                     Page No. 24 / 31                   Report Format Version: 6.1.1


4.3.7       Test Results

FOR PEAK POWER
  Channel           Frequency (MHz) Peak Power (mW) Peak Power (dBm)                Limit (dBm)           Pass/Fail
        0                  2402          0.968                      -0.14               30                   Pass
     19                    2440          0.912                      -0.40               30                   Pass
     39                    2480          0.793                      -1.01               30                   Pass


FOR AVERAGE POWER
                                    Frequency                       Average Power              Average Power
             Channel
                                      (MHz)                             (mW)                       (dBm)
                0                      2402                             0.942                        -0.26
               19                      2440                             0.879                        -0.56
               39                      2480                             0.764                        -1.17




Report No.: RF191016D01-1                        Page No. 25 / 31                            Report Format Version: 6.1.1


4.4     Power Spectral Density Measurement
4.4.1    Limits of Power Spectral Density Measurement

 The Maximum of Power Spectral Density Measurement is 8dBm per 3 kHz.



4.4.2    Test Setup



                 EUT                                              Spectrum
                                               Attenuator         Analyzer



4.4.3    Test Instruments

 Refer to section 4.1.2 to get information of above instrument.



4.4.4    Test Procedure

 a. Set analyzer center frequency to DTS channel center frequency.
 b. Set the span to 1.5 times the DTS bandwidth.
 c. Set the RBW to: 3 kHz ≤ RBW ≤ 100 kHz.
 d. Set the VBW ≥ 3 × RBW.
 e. Detector = peak.
 f. Sweep time = auto couple.
 g. Trace mode = max hold.
 h. Allow trace to fully stabilize.
 i. Use the peak marker function to determine the maximum amplitude level within the RBW.

4.4.5    Deviation from Test Standard

 No deviation.



4.4.6    EUT Operating Condition

 Same as Item 4.2.6.




Report No.: RF191016D01-1                     Page No. 26 / 31                    Report Format Version: 6.1.1


4.4.7     Test Results

                             Freq.              PSD                Limit              PASS
        Channel
                            (MHz)            (dBm/3kHz)         (dBm/3kHz)            /FAIL
          0                 2402                 -16.80             8                 PASS
          19                2440                 -17.16             8                 PASS
          39                2480                 -17.65             8                 PASS



                                     SPECTRUM PLOT OF WORST VALUE
                                                 CH 0




Report No.: RF191016D01-1                    Page No. 27 / 31                Report Format Version: 6.1.1


4.5     Conducted Out of Band Emission Measurement
4.5.1    Limits of Conducted Out of Band Emission Measurement

Below –20dB of the highest emission level of operating band (in 100kHz Resolution Bandwidth).



4.5.2    Test Setup




                EUT                                               Spectrum
                                             Attenuator
                                                                  Analyzer



4.5.3    Test Instruments

Refer to section 4.1.2 to get information of above instrument.

4.5.4    Test Procedure

MEASUREMENT PROCEDURE REF
1. Set the RBW = 100 kHz.
2. Set the VBW ≥ 300 kHz.
3. Detector = peak.
4. Sweep time = auto couple.
5. Trace mode = max hold.
6. Allow trace to fully stabilize.
7. Use the peak marker function to determine the maximum power level in any 100 kHz band segment within
   the fundamental EBW.

MEASUREMENT PROCEDURE OOBE
1. Set RBW = 100 kHz.
2. Set VBW ≥ 300 kHz.
3. Detector = peak.
4. Sweep = auto couple.
5. Trace Mode = max hold.
6. Allow trace to fully stabilize.
7. Use the peak marker function to determine the maximum amplitude level.

4.5.5 Deviation from Test Standard
No deviation.

4.5.6    EUT Operating Condition

 Same as Item 4.2.6.




Report No.: RF191016D01-1                      Page No. 28 / 31                    Report Format Version: 6.1.1


4.5.7   Test Results

                                           CH 0




                                          CH 19




                                          CH 39




                    CH 0 Band edge                      CH 39 Band edge




Report No.: RF191016D01-1            Page No. 29 / 31             Report Format Version: 6.1.1


5    Pictures of Test Arrangements


 Please refer to the attached file (Test Setup Photo).




Report No.: RF191016D01-1                      Page No. 30 / 31   Report Format Version: 6.1.1


Appendix – Information of the Testing Laboratories

We, Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch, were founded in 1988 to
provide our best service in EMC, Radio, Telecom and Safety consultation. Our laboratories are FCC
recognized accredited test firms and accredited according to ISO/IEC 17025.

If you have any comments, please feel free to contact us at the following:

Lin Kou EMC/RF Lab                                     Hsin Chu EMC/RF/Telecom Lab
Tel: 886-2-26052180                                    Tel: 886-3-6668565
Fax: 886-2-26051924                                    Fax: 886-3-6668323

Hwa Ya EMC/RF/Safety Lab
Tel: 886-3-3183232
Fax: 886-3-3270892

Email: service.adt@tw.bureauveritas.com
Web Site: www.bureauveritas-adt.com

The address and road map of all our labs can be found in our web site also.



--- END ---




Report No.: RF191016D01-1                      Page No. 31 / 31                 Report Format Version: 6.1.1



Document Created: 2019-11-05 11:30:25
Document Modified: 2019-11-05 11:30:25

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC