                                                                                                 869-894 MHz




                                                           Installation & Service
                                                                   Manual




                                                Model SCA 9321-30C
                                           Single-Channel Cellular Amplifier




                   Copyright Powerwave Technologies, Inc., February 2003. All rights reserved
044-xxxxx Rev.A                                                                                      February 2003


                                                  SCA 9321-30C Installation & Service Manual




 © 2003 Powerwave Technologies Incorporated. All rights reserved.

 Powerwave Technologies, and the Powerwave logo are registered trademarks

 Powerwave Technologies, Inc. reserves the right to make changes to the documentation and
 equipment, including but not limited to component substitution and circuitry changes. Changes
 that impact this manual may subsequently be incorporated in a later revision of this manual.




                                              February 2003


Powerwave Technologies, Inc.                                                         Tel: (714) 466-1000
1801 East St. Andrew Place                                                                (888) 797-9283
Santa Ana, CA 92705                                                                  Fax: (714) 466-5800
                                                                          Web Site: www.powerwave.com

                    Copyright Powerwave Technologies, Inc., February 2003. All rights reserved
044-xxxxx Rev. A                                       ii                                         February 2003


                                                                       SCA 9321-30C Installation & Service Manual

                                                      Table Of Contents

Par.                                                        Section 1                                                                          Page
No.                                                     General Description                                                                     No.

1-1      Introduction............................................................................................................................. 1-1
1-2      General Description................................................................................................................. 1-1
1-3      Functional and Physical Specifications .................................................................................... 1-1
1-4      Equipment Changes................................................................................................................. 1-1

                                                                Section 2
                                                               Installation
2-1      Introduction............................................................................................................................. 2-1
2-2      Electrical Service Recommendations ....................................................................................... 2-1
2-3      Unpacking and Inspection ....................................................................................................... 2-1
2-4      Installation Instructions ........................................................................................................... 2-2
2-5      Amplifier Module Connectors.................................................................................................. 2-2
2-5.1    Data I/O Connector ................................................................................................................. 2-3
2-5.2    Amplifier RF Connectors......................................................................................................... 2-4
2-5.3    DC Power Connector ............................................................................................................... 2-4


                                                           Section 3
                                                      Operating Instructions
3-1      Introduction............................................................................................................................. 3-1
3-2      Location and Function of Amplifier Indicators......................................................................... 3-1
3-3      Initial Start-Up and Operating Procedures ............................................................................... 3-1

                                                            Section 4
                                                     Principles of Operation
4-1      Introduction............................................................................................................................. 4-1
4-2      RF Input Signal ....................................................................................................................... 4-1
4-3      RF Output Load....................................................................................................................... 4-1
4-4      SCA 9321-30C Amplifier ........................................................................................................ 4-1
4-4.1    Driver Amplifier...................................................................................................................... 4-2
4-4.2    Main Amplifier ....................................................................................................................... 4-2
4-4.3    Power Distribution................................................................................................................... 4-2
4-4.4    Multifunction Board ................................................................................................................ 4-2

                                                               Section 5
                                                              Maintenance
5-1      Periodic Maintenance .............................................................................................................. 5-1




                          Copyright Powerwave Technologies, Inc., February 2003. All rights reserved
044-xxxxx Rev. A                                                        iii                                                         February 2003


                                                                       SCA 9321-30C Installation & Service Manual


                                                              Section 6
                                                           Troubleshooting

6-1      Introduction............................................................................................................................. 6-1
6-2      Trouble shooting...................................................................................................................... 6-1
6-3      Return for Service Procedures.................................................................................................. 6-1
6-3.1    Obtaining an RMA .................................................................................................................. 6-1
6-3.2    Repackaging for Shipment....................................................................................................... 6-1



                                                        List Of Illustrations
Figure                                                                                                                                         Page
No.                                                                                                                                             No.

1-1      SCA 9321-30C Amplifier ........................................................................................................ 1-3
2-1      SCA 9321-30C Front Panel View ............................................................................................ 2-2
2-2      Data I/O Connector ................................................................................................................. 2-3
2-3      DC Power Connector ............................................................................................................... 2-4
3-1      Front Panel Indicators ............................................................................................................. 3-1
4-1      SCA 9321-30C Amplifier Block Diagram................................................................................ 4-1

                                                            List Of Tables
Table                                                                                                                                          Page
No.                                                                                                                                             No.

1-1      SCA 9321-30C Single-Channel Cellular Amplifier Functional Specifications.......................... 1-2
2-1      Data I/O Connector Pin Definition........................................................................................... 2-3
2-2      Amplifier RF Connector Definition ......................................................................................... 2-4
2-3      DC Power Connector Definition ............................................................................................. 2-4
6-1      Troubleshooting....................................................................................................................... 6-1




                          Copyright Powerwave Technologies, Inc., February 2003. All rights reserved
044-xxxxx Rev. A                                                        iv                                                          February 2003


                                                             SCA 9321-30C Installation & Service Manual


Section 1 General Description
1-1 Introduction
This manual contains information and procedures for installation, operation, and maintenance of
Powerwave’s SCA 9321-30C (Nortel Model No. NTQA37AA) single-channel cellular amplifier.
The manual is organized into six sections as follows:
  Section 1. General Description
  Section 2. Installation
  Section 3. Operating Instructions
  Section 4. Principles of Operation
  Section 5. Maintenance
  Section 6. Troubleshooting


1-2 General Description
The SCA 9321-30C (see figure 1-1) is a single-channel power amplifier that operates in the 25
MHz frequency band from 869 MHz to 894 MHz. It is designed for use in an amplifier system
that is modular in design, and is ideally suited for use in GSM/EDGE base stations. The amplifier
is capable of transmitting at 30 watts of power in either GMSK or EDGE modulation. All
solid-state, the amplifier is designed to provide trouble-free operation with minimum mainte-
nance. The system's modular construction and unique and highly effective operational status and
fault monitoring circuitry help minimize downtime. The turn-on and turn-off sequences of volt-
ages are fully automatic, as is overload protection.
Each amplifier module has an I/O connector that allows the host system to monitor the amplifier
module performance. Primary power for the amplifier is –48 Vdc. The amplifier has an integrated
heat sink for cooling.

1-3 Functional And Physical Specifications
Functional and physical specifications for the amplifier are listed in table 1-1.


1-4 Equipment Changes
Powerwave Technologies, Inc. reserves the right to make minor changes to the equipment, in-
cluding but not necessarily limited to component substitution and circuitry changes. Changes that
impact this manual may subsequently be incorporated in a later revision of this manual.




                          Copyright Powerwave Technologies, Inc., February 2003. All rights reserved
          All specifications are subject to change without notice. Contact the factory for complete performance data.
044-xxxxx Rev. A                                              1-1                                                February 2003


                                                             SCA 9321-30C Installation & Service Manual



   Table 1-1 SCA 9321-30C Single-Channel Cellular Amplifier Functional Specifications
 Frequency Range                                  869-894 MHz
 Nominal Input Power                              -0.2 dBm
 Total Output Power                               30 W (44.8 dBm) maximum
 RF Gain at 882 MHz                               45 +/- 0.5 dB
 Gain Variation Over All Condi-                   ±2.0 dB
 tions:
 Output Protection:                               Mismatch Protected
 Input Port Return Loss:                          -14 dB (Min)
 Out of Band Spurious:                            -50 dBc (max)
 Spectral Mask                                    Frequency Removed From Carrier GSM                           EDGE

                                                  200 kHz                              -31 dBc -31 dBc
                                                  250 kHz                              -34 dBc -34 dBc
                                                  400 kHz                              -61 dBc -57 dBc
                                                  600 kHz                              -71 dBc -71 dBc
                                                  1200 kHz                             -74 dBc -74 dBc
                                                  1800 kHz                             -76 dBc -76 dBc
                                                  6000 kHz                             -81 dBc -81 dBc
 Duty Cycle:                                      Continuous
 DC Input Power:                                  -48 VDC; 2.9 amps typical; 4.2 amps max.
                                                  -36 to –60 VDC, 140 watts typical; 200 watts max.
 Heat Dissipation                                 375 BTUs typical
 Operating Temperature:                           0 ºC. to +60 ºC.
 Storage Temperature:                             -40 ºC. to +75 ºC.
 Operating Humidity:                              5 % - 95 % Relative Humidity (Noncondensing)
 Storage Humidity:                                5 % - 95 % Relative Humidity (Noncondensing)
 RF Input / Output Connector                      SMA Female (Input) / Type N Female (Output)
 DC Power Connector                               3-Pin D-Subminiature (20 A Contacts)
 Data I/O Connector                               20-Pin SCSI
 Dimensions:                                      2.55” High, 9.48” Wide, 11.85” Deep




                          Copyright Powerwave Technologies, Inc., February 2003. All rights reserved
          All specifications are subject to change without notice. Contact the factory for complete performance data.
044-xxxxx Rev. A                                              1-2                                                February 2003


                                                             SCA 9321-30C Installation & Service Manual




                                                                          All dimensions are in inches
                                                                          And are for reference only




                                       Figure 1-1. SCA 9321-30C Amplifier


                          Copyright Powerwave Technologies, Inc., February 2003. All rights reserved
          All specifications are subject to change without notice. Contact the factory for complete performance data.
044-xxxxx Rev. A                                              1-3                                                February 2003


                                                         SCA 9321-30C Installation & Service Manual


Section 2 Installation
2-1 Introduction
This section contains installation recommendations, unpacking, inspection, and installation in-
structions for the SCA 9321-30C single channel cellular amplifier. Carefully read all material in
this section prior to equipment unpacking or installation. Also read and review the operating pro-
cedures in Section 3 prior to installing the equipment. It is important that the licensee perform
these tasks correctly and in good faith. If applicable, carefully read the Federal Communications
Commission (FCC) rules to determine how they apply to your installation. DON'T TAKE
CHANCES WITH YOUR LICENSE.

2-2 Electrical Service Recommendations
Powerwave Technologies recommends that proper AC line conditioning and surge suppression
be provided on the primary AC input to the -48 Vdc power source. All electrical service should be
installed in accordance with the National Electrical Code, any applicable state or local codes, and
good engineering practice. Special consideration should be given to lightning protection of all
systems in view of the vulnerability of most transmitter sites to lightning. Lightning arrestors are
recommended in the service entrance. Straight, short ground runs are recommended. The elec-
trical service must be well grounded.
The amplifier has an internal fuse, so a failure in one does not shut off the whole installation.

2-3 Unpacking And Inspection
This equipment has been operated, tested and calibrated at the factory. Only in the event of se-
vere shocks or other mistreatment should any substantial readjustment be required. Carefully
open the container(s) and remove the amplifier module(s). Retain all packing material that can
be reassembled in the event that the unit must be returned to the factory.

                                                   CAUTION
           Exercise care in handling equipment during inspection to prevent damage caused by
           rough or careless handling.

Visually inspect the amplifier module for damage that may have occurred during shipment.
Check for evidence of water damage, bent or warped chassis, or loose screws or nuts. Inspect
the front panel for bent connector pins. If the equipment is damaged, a claim should be filed with
the carrier once the extent of any damage is assessed. We cannot stress too strongly the im-
portance of IMMEDIATE careful inspection of the equipment and the subsequent IMMEDIATE
filing of the necessary claims against the carrier if necessary. If possible, inspect the equipment
in the presence of the delivery person. If the equipment is damaged, the carrier is your first area
of recourse. If the equipment is damaged and must be returned to the factory, write or phone for
a return authorization. Powerwave may not accept returns without a return authorization. Claims
for loss or damage may not be withheld from any payment to Powerwave, nor may any payment
due be withheld pending the outcome thereof. WE CANNOT GUARANTEE THE FREIGHT
CARRIER'S PERFORMANCE.




                     Copyright Powerwave Technologies, Inc., February 2003. All rights reserved
044-xxxxx Rev. A                                       2-1                                         February 2003


                                                         SCA 9321-30C Installation & Service Manual

2-4 Installation Instructions (Refer to figures 1-1 and 2-1)
The SCA 9321-30C is intended for installation in a Restricted Access Location.
The SCA 9321-30C amplifier module is designed for installation in a subrack that permits access
to the amplifier’s front panel for connection of DC power, RF, and monitor cables.
To install the amplifier proceed as follows:
1.   Install amplifier in the BTS rack and secure in place.
2.   Connect the amplifier front panel RF Out (Type-N) connector to the antenna cable.
3.   Connect the amplifier front panel RF In (Type-SMA) connector to the transceiver output(s).
4.   Connect the BTS 20-pin Data I/O cable to the amplifier. Refer to section 2-5.1.

                                                   WARNING
           Turn off external DC power before connecting DC power cables. Verify that the
           amplifier is terminated into a proper 50 Ohm load.

5.   Connect the DC power cable to the rack and amplifier. Refer to section 2-5.3.
6.   Check your work before applying DC voltage to the system. Make certain all connections
     are tight and correct.
7.   Measure DC input voltage. DC input voltage should be -36 to –60 VDC. If the DC input volt-
     age is above or below the limits, call and consult Powerwave before you turn on your ampli-
     fier system.
8.   Refer to section 3 for initial turn-on and checkout procedures.

2-5 Amplifier Module Connectors
The amplifier has four connectors on the front of the module. These include a SCSI connector
which provides the data I/O connections, SMA female RF input, Type N female RF output, and
3-pin high current contact DC input connectors. Refer to figure 2-1. Each is fully described in the
paragraphs that follow.




                             Figure 2-1 SCA 9321-30C Front Panel View




                     Copyright Powerwave Technologies, Inc., February 2003. All rights reserved
044-xxxxx Rev. A                                       2-2                                         February 2003


                                                         SCA 9321-30C Installation & Service Manual


2-5.1 Data I/O Connector

The amplifier has a separate remote alarm and control connector that may be used by the host
system to monitor and control the individual amplifier modules. The status, alarm, and control
connections on the amplifier connector are made through a 20-pin SCSI connector (figure 2-2)
and are listed and described in table 2-1.




                           Figure 2-2 Data I/O Connector (on Front Panel)

                           Table 2-1 Data I/O Connector Pin Definition
                   Pin     Function                     Description
                    1      Ground                       Ground
                    2      Ground                       Ground
                    3      Synchro Signal +             Synchro Signal from TRX
                    4      UART TX +                    Information Exchange (TRX to PA)
                    5      Manual Control               To Set PA in Test Mode
                    6      Not Connected
                    7      UART RX +                    Information Exchange (PA to TRX)
                    8      Not Connected
                    9      Not Connected
                   10      Not Connected
                   11      Ground                       Ground
                   12      Ground                       Ground
                   13      Synchro Signal -             Synchro Signal from TRX
                   14      UART TX -                    Information Exchange (TRX to PA)
                   15      Not Connected
                   16      Not Connected
                   17      UART RX -                    Information Exchange (PA to TRX)
                   18      Not Connected
                   19      Not Connected
                   20      Not Connected




                     Copyright Powerwave Technologies, Inc., February 2003. All rights reserved
044-xxxxx Rev. A                                       2-3                                         February 2003


                                                        SCA 9321-30C Installation & Service Manual

2-5.2 Amplifier RF Connectors

The amplifier has two RF connectors. The RF Input connector is a SMA female. The input power
on this port should not exceed the level specified in table 1-1. The RF Output connector is Type
N female. They are listed and described in table 2-2.

                          Table 2-2 Amplifier RF Connector Definition
                                  Function            Description
                                  RF Input            SMA Female
                                  RF Output           Type N Female

2-5.3 DC Power Connector

The DC power connector is a three-pin high current contact D-subminiature connector. The pin
configuration is listed in table 2-3 and shown in figure 2-3.

                            Table 2-3 DC Power Connector Definition
                                    Pin          Description
                                     1           -48 V
                                     2           Chassis Ground
                                     3           Battery Return




                                   Figure 2-3 DC Power Connector




                    Copyright Powerwave Technologies, Inc., February 2003. All rights reserved
044-xxxxx Rev. A                                      2-4                                         February 2003


                                                         SCA 9321-30C Installation & Service Manual


Section 3 Operating Instructions
3-1 Introduction
This section contains operating instructions for the single channel cellular amplifier system.

3-2 Location And Function Of Amplifier Indicators
The front panel LED is located to the right of the 20-pin Data connector and indicates the ampli-
fier status.
     • Green means the amplifier is operating properly.
     • Red indicates an alarm or off condition.
The nature of the alarm can only be determined through the software interface of the Base-
Transceiver System (BTS). Please consult the BTS manual for details on monitoring amplifier
status.
                                                Front Panel Status Indicator




                                    Figure 3-1 Front Panel Indicators


3-3 Initial Start-Up And Operating Procedures
To perform the initial start-up, proceed as follows:
1.   Verify that all input and output cables are properly connected.

                                                   CAUTION
           Before applying power, make sure that the input and output of the amplifier are
           properly terminated at 50 ohms. Do not operate the amplifier without a load
           attached. Refer to table 1-1 for input power requirements. Excessive input power
           may damage the amplifier


                                                      NOTE
           The output coaxial cable between the amplifier and the antenna must be 50 ohm
           coaxial cable. Use of any other cable will distort the output.

2.   Turn on supply that provides -48 Vdc to the amplifier system. Do not apply an RF signal to
     the amplifier system
3.   Verify that the LED is lit and the color Green.
4.   Turn on external exciter/transceiver and apply RF input signals. Adjust the input power to
     achieve the desired output power. Refer to the BTS manual for instructions on performing
     this step.

                     Copyright Powerwave Technologies, Inc., February 2003. All rights reserved
044-xxxxx Rev. A                                       3-1                                         February 2003


                                                        SCA 9321-30C Installation & Service Manual


Section 4 Principles of Operation
4-1 Introduction
This section contains a functional description of the single-carrier SCA 9321-30C amplifier.

4-2 RF Input Signal
The maximum input power should not exceed the levels to produce the maximum rated RF out-
put power in table 1-1. This level is approximately 0 dBm, but should be set through the base-
transceiver station’s software interface. See the BTS manual for detailed instructions.

4-3 RF Output Load
The load impedance should be as good as possible (1.5:1 or better) in the working band for good
power transfer to the load.

4-4 SCA 9321-30C Amplifier
The amplifier, figure 4-1, has an average output power of 30 watts, and is designed to support
transmission in GMSK and EDGE modulation. With an input signal of approximately 0 dBm, the
amplifier will operate at its rated output power. The amplifier is comprised of:
        Driver Amplifier
        Main Amplifier
        Multifunction Board
        DC/DC Converter Module
                                                                               Main Amp


                                         Driver



                                                                                                  Det


                          Temp Sense



            DAC                                   Multifunction                           +26
                                                                       5 V Reg.

                           MCU                                          Current Sense
                                                                                                  DC/DC
                                                                          Input Filter/           -48/+26
         RS-485 Intfc            Red/                                      Protection
                            3
                                 Grn                                            Power Supply
            20-pin SCSI                      PWR Conn



                          Figure 4-1 SCA 9321-30C Amplifier Block Diagram


                    Copyright Powerwave Technologies, Inc., February 2003. All rights reserved
044-05113 Rev.A                                        4-1                                              February 2003


                                                        SCA 9321-30C Installation & Service Manual

4-4.1 Driver Amplifier

The driver amplifier is a two-stage amplifier which provides approximately 28 dB of gain in the
25 MHz frequency band from 869 to 894 MHz. The amplifier is mounted directly on a heat sink,
which is temperature monitored by a thermal sensor.

4-4.2 Main Amplifier

The main amplifier is a single-stage Class AB amplifier with approximately 13 dB gain and a
P1dB of +50 dBm. The amplifier’s output is protected from output mismatches. The amplifier is
designed to meet spectral mask requirements for GSM and EDGE signals when operated up to
+45.2 dBm. The amplifier is mounted directly on a heat sink.

4-4.3 Power Distribution

The amplifier module operates on a –48 VDC nominal power supply consuming 2.9 amps (typi-
cally) current at full power. A DC/DC converter to supply internal circuitry with +26 VDC and +5
VDC.

4-4.4 Multifunction Board

The multifunction board enables communication between the amplifier and the base-transceiver
station in which it is installed, and stores information about the amplifier. It includes gain control
and two gain stages providing 7 dB gain. The multifunction board also monitors several ampli-
fier performance parameters and reports output power so that the BTS can maintain the output
power within specified limits. When these parameters are beyond acceptable levels, the ampli-
fier will alarm. The multifunction board is mounted directly on a heat sink, which is temperature
monitored by a thermal sensor.
The alarms are:
     Temperature Alarm - If the internal temperature reaches 90°C, the PA shuts down and
          communicates an alarm through the digital interface.
     DC/DC Alarm - If the output voltage of the converter falls below 23.5V, the PA shuts down
          and communicates an alarm through the digital interface.
     Over-current Alarm - If the output current of the DC/DC converter goes above a nominal
           threshold (7.5 A), the PA shuts down and communicates an alarm through the digital
           interface.
     Communication Alarm - If the serial interface detects an error in transmission (parity, over-
          run, framing), an alarm is sent for one burst only during the very next burst. The PA
          operation is not affected.




                    Copyright Powerwave Technologies, Inc., February 2003. All rights reserved
044-05113 Rev.A                                       4-2                                         February 2003


                                                       SCA 9321-30C Installation & Service Manual


Section 5 Maintenance
5-1 Introduction
The amplifier is designed to be operated without any required periodic maintenance other than
maintenance which may be recommended by the manufacturer of the BTS. Please consult your
BTS manual for guidance.




                    Copyright Powerwave Technologies, Inc., February 2003. All rights reserved
044-xxxxx Rev. A                                      5-1                                         February 2003


                                                            SCA 9321-30C Installation & Service Manual


Section 6 Troubleshooting
6-1 Introduction
This section contains a list of problems and a few suggested actions that may correct the prob-
lem. If the suggested corrective action does not eliminate the problem, please contact your
Powerwave field representative or the factory for further instructions.

                                                         NOTE
           Check your sales order and equipment warranty before attempting to service or
           repair the unit. Do not break the seals on equipment under warranty or the warranty
           will be null and void. Do not return equipment for warranty or repair service until
           proper shipping instructions are received from the factory.


6-2 Troubleshooting
Refer to table 6-1 for troubleshooting suggestions.

                                          Table 6-1 Troubleshooting
 Symptom                                                 Suggested Action
                   1. Check that rack power connection is secure.
 LED not lit       2. Check for proper power supply voltage.
                   3. Check that power switch is ON position.
                   1. Verify amplifier is enabled.
                   2. A large RF input overdrive has caused an alarm. Reduce input power and
 LED is red
                      re-enable the amplifier.
                   3. Follow recommendations of BTS operating manual.
                   1. Check input and output connections and cables for integrity and tightness.
 No RF             2. Check RF input power to verify that it is present and within specification
 Output               range.
                   3. Contact Powerwave field representative or factory.

6-3 Return For Service Procedures
When returning products to Powerwave, the following procedures will ensure optimum response.

6-3.1 Obtaining An RMA

A Return Material Authorization (RMA) number must be obtained prior to returning equipment to
the factory for service. Please contact our Repair Department at (888) 797-9283 or (714) 466-
1000 to obtain this number, or FAX your request to (714) 466-5816. Failure to obtain this RMA
number may result in delays in receiving repair service.

6-3.2 Repackaging For Shipment




                        Copyright Powerwave Technologies, Inc., February 2003. All rights reserved
044-xxxxx Rev. A                                          6-1                                         February 2003