Test Report

FCC ID: E2K-P05G

Test Report

Download: PDF
FCCID_1247431

               Report No: T100127102-RP1     FCC ID: E2K-P05G     Date of Issue: Feb. 3, 2010



                        FCC 47 CFR PART 15 SUBPART C

                                    TEST REPORT

                                              For

                                Notebook Computer

                              Regulatory Model: P05G

                            Regulatory Type: P05G001

                                 Trade Name: DELL


                                            Issued to

                     Dell Computer Corporation
           ONE DELL WAY, ROUND ROCK, TEXAS 78682, U.S.A.

                                           Issued by

                   Compliance Certification Services Inc.
              No. 81-1, Lane 210, Pa-De 2nd Rd., Luchu Hsiang,
                     Taoyuan Shien, (338) Taiwan, R.O.C.
                                  TEL: 886-3-324-0332
                                  FAX: 886-3-324-5235
                                  http://www.ccsrf.com
                                   service@ccsrf.com




Note: This report shall not be reproduced except in full, without the written approval of
Compliance Certification Services Inc. This document may be altered or revised by
Compliance Certification Services Inc. personnel only, and shall be noted in the revision
section of the document. The client should not use it to claim product endorsement by TAF,
A2LA, NIST or any government agencies. The test results in the report only apply to the
tested sample.


                                           Page 1 / 26


                     Report No: T100127102-RP1             FCC ID: E2K-P05G                   Date of Issue: Feb. 3, 2010



                                                   Revision History

                  Issue
Rev.                                                       Revisions                       Effect Page      Revised By
                   Date
00       Dec. 22, 2009                  Initial Issue                                           ALL          Jill Shiau




                                                           Page 2
     This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


                       Report No: T100127102-RP1                  FCC ID: E2K-P05G                       Date of Issue: Feb. 3, 2010


                                             TABLE OF CONTENTS
1    TEST RESULT CERTIFICATION..................................................................................... 4

2    EUT DESCRIPTION ......................................................................................................... 5

3    TEST METHODOLOGY ................................................................................................... 6
    3.1.    EUT CONFIGURATION ........................................................................................... 6
    3.2.    EUT EXERCISE ....................................................................................................... 6
    3.3.    GENERAL TEST PROCEDURES ............................................................................ 6
    3.4.    FCC PART 15.205 RESTRICTED BANDS OF OPERATIONS................................ 7
    3.5.    DESCRIPTION OF TEST MODES........................................................................... 7

4    INSTRUMENT CALIBRATION......................................................................................... 8
    4.1.    MEASURING INSTRUMENT CALIBRATION .......................................................... 8
    4.2.    MEASUREMENT EQUIPMENT USED .................................................................... 8
    4.3.    MEASUREMENT UNCERTAINTY ........................................................................... 9

5    FACILITIES AND ACCREDITATIONS........................................................................... 10
    5.1.    FACILITIES ............................................................................................................ 10
    5.2.    EQUIPMENT .......................................................................................................... 10
    5.3.    TABLE OF ACCREDITATIONS AND LISTINGS.................................................... 11

6    SETUP OF EQUIPMENT UNDER TEST........................................................................ 12
    6.1.    SETUP CONFIGURATION OF EUT ...................................................................... 12
    6.2.    SUPPORT EQUIPMENT........................................................................................ 12

7    FCC PART 15.225 REQUIREMENTS ............................................................................ 13
    7.1.    RADIATED EMISSIONS ........................................................................................ 13
    7.2.    FREQUENCY STABILITY ...................................................................................... 19
    7.3.    POWERLINE CONDUCTED EMISSIONS ............................................................. 21

APPENDIX I PHOTOGRAPHS OF TEST SETUP ............................................................... 24




                                                                  Page 3
     This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


                   Report No: T100127102-RP1             FCC ID: E2K-P05G                   Date of Issue: Feb. 3, 2010


1 TEST RESULT CERTIFICATION
                                    Dell Computer Corporation
Applicant:
                                    ONE DELL WAY, ROUND ROCK, TEXAS 78682, U.S.A.
Equipment Under Test:               Notebook Computer
Trade Name:                         DELL
Regulatory Model:                   P05G
Regulatory Type:                    P05G001
Date of Test:                       February 1, 2010



                                     APPLICABLE STANDARDS
                     STANDARD                                                  TEST RESULT
       FCC 47 CFR Part 15 Subpart C                                     No non-compliance noted


We hereby certify that:
The above equipment was tested by Compliance Certification Services Inc. The test data,
data evaluation, test procedures, and equipment configurations shown in this report were
made in accordance with the procedures given in ANSI C63.4: 2003 and the energy
emitted by the sample tested as described in this report is in compliance with the
requirements of FCC Rules Part 15.207, 15.209, 15.225.
The test results of this report relate only to the tested sample identified in this report.




Approved by:                                                     Reviewed by:




Ethan Huang                                                      Stan Lin
Section Manager                                                  Supervisor



                                                         Page 4
   This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


                   Report No: T100127102-RP1             FCC ID: E2K-P05G                   Date of Issue: Feb. 3, 2010


2 EUT DESCRIPTION
Product                                   Notebook Computer

Trade Name                                DELL

Regulatory Model                          P05G

Regulatory Type                           P05G001

Model Difference                          N/A

EUT Power Rating                          19.5VDC, 4.62A

Power Adapter Manufacturer                DELL                    Model         LA90PE0-01
                                          I/P: 100-240Vac, 50-60Hz, 1.5A
Power Adapter Power Rating
                                          O/P: 19.5V, 4.62A
Operating Frequency Range                 13.56MHz

Modulation Technique                      ASK/BPSK

Number of Channels                        1 Channels

Antenna Specification                     Coil Antenna

Remark:
    1.    The sample selected for test was engineering sample that approximated to production
          product and was provided by manufacturer.
    2.    This submittal(s) (test report) is intended for FCC ID: E2K-P05G filing to comply with
          Section 15.225 of the FCC Part 15, Subpart C Rules.




                                                         Page 5
   This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


                   Report No: T100127102-RP1             FCC ID: E2K-P05G                   Date of Issue: Feb. 3, 2010

3 TEST METHODOLOGY
The tests documented in this report were performed in accordance with ANSI C63.4 (2003)
and FCC CFR 47 Part 2, 15.207, 15.209 and 15.225.
3.1. EUT CONFIGURATION
The EUT configuration for testing is installed on RF field strength measurement to meet the
Commissions requirement and operating in a manner that intends to maximize its emission
characteristics in a continuous normal application.
3.2. EUT EXERCISE
The EUT was operated in the engineering mode to fix the TX frequency that was for the
purpose of the measurements.
3.3. GENERAL TEST PROCEDURES
Conducted Emissions
The EUT is placed on the turntable, which is 0.8 m above ground plane. According to the
requirements in Section 13.1.4.1 of ANSI C63.4 (2003). Conducted emissions from the
EUT measured in the frequency range between 0.15 MHz and 30MHz using CISPR
Quasi-peak and average detector modes.

Radiated Emissions
The EUT is placed on a turn table, which is 0.8 m above ground plane. The turntable shall
rotate 360 degrees to determine the position of maximum emission level. EUT is set 3m
away from the receiving antenna, which varied from 1m to 4m to find out the highest
emission. And also, each emission was to be maximized by changing the polarization of
receiving antenna both horizontal and vertical. In order to find out the maximum emissions,
exploratory radiated emission measurements were made according to the requirements in
Section 13.1.4.1 of ANSI C63.4 (2003).




                                                         Page 6
   This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


                   Report No: T100127102-RP1             FCC ID: E2K-P05G                   Date of Issue: Feb. 3, 2010


3.4. FCC PART 15.205 RESTRICTED BANDS OF OPERATIONS
(a) Except as shown in paragraph (d) of this section, only spurious emissions are permitted
    in any of the frequency bands listed below:

               MHz                            MHz                          MHz                      GHz
           0.090 - 0.110      16.42 - 16.423     399.9 - 410                                    4.5 - 5.15
          1
           0.495 - 0.505   16.69475 - 16.69525    608 - 614                                    5.35 - 5.46
         2.1735 - 2.1905   16.80425 - 16.80475   960 - 1240                                    7.25 - 7.75
          4.125 - 4.128         25.5 - 25.67     1300 - 1427                                   8.025 - 8.5
        4.17725 - 4.17775       37.5 - 38.25    1435 - 1626.5                                    9.0 - 9.2
        4.20725 - 4.20775         73 - 74.6    1645.5 - 1646.5                                   9.3 - 9.5
          6.215 - 6.218         74.8 - 75.2      1660 - 1710                                   10.6 - 12.7
        6.26775 - 6.26825      108 - 121.94    1718.8 - 1722.2                                 13.25 - 13.4
        6.31175 - 6.31225        123 - 138       2200 - 2300                                   14.47 - 14.5
          8.291 - 8.294       149.9 - 150.05     2310 - 2390                                   15.35 - 16.2
          8.362 - 8.366        156.52475 -      2483.5 - 2500                                  17.7 - 21.4
        8.37625 - 8.38675        156.52525       2655 - 2900                                  22.01 - 23.12
        8.41425 - 8.41475      156.7 - 156.9     3260 - 3267                                   23.6 - 24.0
          12.29 - 12.293    162.0125 - 167.17    3332 - 3339                                   31.2 - 31.8
       12.51975 - 12.52025    167.72 - 173.2    3345.8 - 3358                                  36.43 - 36.5
       12.57675 - 12.57725       240 - 285       3600 - 4400                                         ( 2)
          13.36 - 13.41         322 - 335.4
   1
       Until February 1, 1999, this restricted band shall be 0.490-0.510 MHz.
   2
       Above 38.6

(b) Except as provided in paragraphs (d) and (e), the field strength of emissions appearing
    within these frequency bands shall not exceed the limits shown in Section 15.209. At
    frequencies equal to or less than 1000 MHz, compliance with the limits in Section
    15.209 shall be demonstrated using measurement instrumentation employing a CISPR
    quasi-peak detector. Above 1000 MHz, compliance with the emission limits in Section
    15.209 shall be demonstrated based on the average value of the measured emissions.
    The provisions in Section 15.35 apply to these measurements.
3.5. DESCRIPTION OF TEST MODES
The EUT had been tested under operating condition.
Software used to control the EUT for staying in continuous transmitting and receiving mode
was programmed.
After verification, all tests carried out were with the worst-case test modes as shown below
except radiated spurious emission worst case was in normal link mode.
RF ID: Channel 13.56MHz was chosen for full testing.




                                                         Page 7
   This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


                   Report No: T100127102-RP1             FCC ID: E2K-P05G                   Date of Issue: Feb. 3, 2010


4 INSTRUMENT CALIBRATION
4.1. MEASURING INSTRUMENT CALIBRATION
The measuring equipment, which was utilized in performing the tests documented herein,
has been calibrated in accordance with the manufacturer's recommendations for utilizing
calibration equipment, which is traceable to recognized national standards.
4.2. MEASUREMENT EQUIPMENT USED
Equipment Used for Emissions Measurement

Remark: Each piece of equipment is scheduled for calibration once a year.
                              Powerline Conducted Emissions Test Site
 Name of Equipment            Manufacturer               Model             Serial Number          Calibration Due
  Spectrum Analyzer                Agilent              E4446A              MY48250064                11/05/2010
  Spectrum Analyzer                  R&S                  FSEB               825829/011              11/02/2010
 USB Power Sensor               BOONTON                  52012                 2061194               06/08/2010



                                            3M Chamber Test Site
 Name of Equipment            Manufacturer               Model             Serial Number          Calibration Due
  Spectrum Analyzer                Agilent              E4446A              MY48250064                11/05/2010
  Spectrum Analyzer                  R&S                  FSEB               825829/011              11/02/2010
    Pre-Amplifier                     HP                 8447D              2944A06530                01/02/2011
    Pre-Amplifier                     HP                 8449B              3008A01738               04/17/2010
  EMI Test Receiver            SCHAFFNER               SCR 3501                   436                 01/26/2011
    Loop Antenna                   EMCO                   6502                   2356                05/28/2010
    Bilog Antenna            SCHWAZBECK               VULB9160                   3084                 09/11/2010
    Horn Antenna                   EMCO                   3115                00022250               05/08/2010
      Turn Table                    CCS                 CC-T-1F                   N/A                    N.C.R
   Antenna Tower                    CCS                 CC-A-1F                   N/A                    N.C.R
       Controller                   CCS                 CC-C-1F                   N/A                    N.C.R
       Test S/W                            LabVIEW 6.1 (Wugu Chamber EMI Teat V1_4.5.3)




                                                         Page 8
   This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


                    Report No: T100127102-RP1             FCC ID: E2K-P05G                   Date of Issue: Feb. 3, 2010




                               Powerline Conducted Emissions Test Site
 Name of Equipment             Manufacturer               Model             Serial Number          Calibration Due
  EMI Test Receiver                   R&S                  ESCI                  100782               06/01/2010
           LISN                       R&S                ENV216                  100066               05/06/2010
           LISN                       R&S               ENV 4200              830326/016              04/15/2010
        Test S/W                                              CCS-3A1-CE-Luchu


4.3. MEASUREMENT UNCERTAINTY
                  Parameter                                                             Uncertainty
         Powerline Conducted Emission                                                     ± 1.7983
   3M Semi Anechoic Chamber / 30MHz ~ 1GHz                                                 ±4.0235
    3M Semi Anechoic Chamber / Above 1GHz                                                 ±3.87318
Remark: This uncertainty represents an expanded uncertainty expressed at approximately the 95%
        confidence level using a coverage factor of k=2.




                                                          Page 9
    This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


                   Report No: T100127102-RP1             FCC ID: E2K-P05G                   Date of Issue: Feb. 3, 2010


5 FACILITIES AND ACCREDITATIONS
5.1. FACILITIES
All measurement facilities used to collect the measurement data are located at

   No.199, Chunghsen Road, Hsintien City, Taipei Hsien, Taiwan, R.O.C.
   Tel: 886-2-2217-0894 / Fax: 886-2-2217-1029

   No.11, Wugong 6th Rd., Wugu Industrial Park, Taipei Hsien 248, Taiwan
   Tel: 886-2-2299-9720 / Fax: 886-2-2298-4045

   No. 81-1, Lane 210, Pa-De 2nd Rd., Luchu Hsiang, Taoyuan Shien, (338) Taiwan,
   R.O.C.
   Tel: 886-3-324-0332 / Fax: 886-3-324-5235
The sites are constructed in conformance with the requirements of ANSI C63.7, ANSI
C63.4 (2003) and CISPR Publication 22.
5.2. EQUIPMENT
Radiated emissions are measured with one or more of the following types of linearly
polarized antennas: tuned dipole, biconical, log periodic, bi-log, and/or ridged waveguide,
horn. Spectrum analyzers with pre-selectors and quasi-peak detectors are used to perform
radiated measurements.
Conducted emissions are measured with Line Impedance Stabilization Networks and EMI
Test Receivers.
Calibrated wideband preamplifiers, coaxial cables, and coaxial attenuators are also used
for making measurements.
All receiving equipment conforms to CISPR Publication 16-1, “Radio Interference
Measuring Apparatus and Measurement Methods.”




                                                         Page 10
   This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


                    Report No: T100127102-RP1             FCC ID: E2K-P05G                   Date of Issue: Feb. 3, 2010


5.3. TABLE OF ACCREDITATIONS AND LISTINGS
 Country Agency Scope of Accreditation                                                  Logo
                           CFR 47, FCC Part15/18, CISPR 22,
                           EN 55022, ICES-003, AS/NZS CISPR 22,
                           VCCI V-3, EN 55011, CISPR 11,
                           IEC/EN 61000-4-2/3/4/5/6/8/11,
                           EN 61000-6-1/2/3/4,
 USA          A2LA
                           EN 55024, CISPR 24, AS/NZS CISPR 24,
                           AS/NZS 61000.6.2, EN 55014-1/-2,
                           ETSI EN 300 386 v1.3.2/v1.3.3,
                           IEC/EN 61000-3-2, AS/NZS 61000.3.2,
                           IEC/EN 61000-3-3, AS/NZS 61000.3.3

              FCC          3/10 meter Open Area Test Sites to perform
 USA
              MRA          FCC Part 15/18 measurements                                              TW1026


                           3/10 meter Open Area Test Sites and
 Japan        VCCI         conducted test sites to perform                              R-2882/2541/2798/725/1868
                           radiated/conducted measurements                              C-402/747/912
                                                                                        T-321/325
                           EN 55014-1, CISPR 14, CNS 13781-1,
                           EN 55013, CISPR 13, CNS 13439,
                           EN 55011, CISPR 11, CNS 13803,
                           PLMN09, IS2045-0, LP0002
                           FCC Part 27/90, Part 15B/C/D/E,
                           RSS-192/193/210/310
                           ETSI EN 300 328/ 300 220-1/ 300 220-2/ 301
 Taiwan       TAF          893/ 301 489-01/ 301 489-03/ 301 489-07 /
                           301 489-17/ 300 440-1/ 300 440-2
                           AS/NZS 4268, AS/NZS 4771
                           CISPR 22, EN 55022, CNS 13438, AS/NZS
                           CISPR 22, VCCI,
                           IEC/EN 61000-4-2/3/4/5/6/8/11,
                           CNS 14676-2/3/4/5/6/8, CNS 14934-2/3,
                           CNS 13783-1, CNS 13439, CNS 13803
                                                                                        SL2-IS-E-0014 / IN-E-0014
                           CNS 13438, CNS 13783-1, CNS 13439,
 Taiwan       BSMI                                                                      /A1-E-0014 /R1-E-0014
                           CNS 14115
                                                                                        /R2-E-0014 /L1-E-0014

              Industry
 Canada                    RSS212, Issue 1                                              IC 2324C-3
              Canada
                                                                                        IC 2324C-5
Note: No part of this report may be used to claim or imply product endorsement by A2LA, TAF or other
government agency.




                                                          Page 11
    This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


                       Report No: T100127102-RP1            FCC ID: E2K-P05G                   Date of Issue: Feb. 3, 2010


6 SETUP OF EQUIPMENT UNDER TEST
6.1. SETUP CONFIGURATION OF EUT
See test photographs attached in Appendix 1 for the actual connections between EUT and
support equipment.
6.2. SUPPORT EQUIPMENT
For Radiated Emission test
 No. Device Type             Brand            Model         Series No.        FCC ID         Data Cable Power Cord

              N/A


                                   **No any support equipment during the test.
For Powerline Conducted Emission test
 No.     Device Type    Brand       Model              Series No.             FCC ID         Data Cable         Power Cord
                                                                                          D-Sub Cable:
  1      LCD Monitor    DELL      2407WFPb    CN-0FC255-46633-660-045S       FCC DoC      Shielded, 1.8m     Unshielded, 1.8m
                                                                                          with two cores
  2      USB Mouse      DELL      MO56UOA              F0Q01BKU              FCC DoC      Unshielded, 1.8m   N/A
                                                                                                             AC I/P:
                                                                                                             Unshielded, 1.8m
           e-SATA           A02170-F22-0
  3                  ST-M10                             FCC DoC                Onnto      Unshielded, 1.8m   DC O/P:
        External HDD            003
                                                                                                             Unshielded, 1.8m
                                                                                                             with a core
          Multimedia
  4                    Logitech   ClearChat                N/A               FCC DoC      Shielded, 1.8m     N/A
           Headset
                                                                                                             AC I/P:
          Notebook                                                                                           Unshielded, 1.8m
                                                                                      LAN Cable:
  5       Computer      DELL        D400                 0932RY             E2K24GBRL                        DC O/P:
                                                                                      Unshielded, 10m
          (Remote)                                                                                           Unshielded, 1.8m
                                                                                                             with a core

Note: Grounding was established in accordance with the manufacturer’s requirements and conditions for the
     intended use.




                                                            Page 12
      This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


                   Report No: T100127102-RP1             FCC ID: E2K-P05G                   Date of Issue: Feb. 3, 2010


7 FCC PART 15.225 REQUIREMENTS
7.1. RADIATED EMISSIONS
LIMIT
According to §15.225,
   (a) The field strength of any emissions within the band 13.553 – 13.567 MHz shall
       not exceed 15,848 microvolts / meter at 30 meters.
   (b) Within the bands 13.410 – 13.553 MHz and 13.567 -13.710 MHz, the field
       strength of any emissions shall not exceed 334 microvolts / meter at 30 meters.
   (c) Within the bands 13.110 – 13.410 MHz and 13.710 – 14.010 MHz the field
       strength of any emissions shall not exceed 106 microvolts / meter at 30 meters.
   (d) The field strength of any emissions appearing outside of the 13.110 – 14.010
       MHz and shall not exceed the general radiated emission limits in §15.209.
According to §15.225(a), except as provided elsewhere in this Subpart, the emissions from
an intentional radiator shall not exceed the field strength levels specified in the following
table:
             Frequency                  Field Strength           Measurement Distance
                (MHz)                  (µV/m at meter)                     (meter)
               0.009 – 0.490                          2400 / F (kHz)                                300
               0.490 – 1.705                         24000 / F (kHz)                                 30
                1.705 – 30.0                                 30                                      30
                   30 - 88                                 100**                                     3
                   88-216                                  150**                                     3
                  216-960                                  200**                                     3
                 Above 960                                  500                                      3
    ** Except as provided in paragraph (g), fundamental emissions from intentional radiators operating
    under this Section shall not be located in the frequency bands 54-72 MHz, 76-88 MHz, 174-216 MHz or
    470-806 MHz. However, operation within these frequency bands is permitted under other sections of
    this Part, e.g., Sections 15.231 and 15.241.




                                                         Page 13
   This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


                  Report No: T100127102-RP1             FCC ID: E2K-P05G                   Date of Issue: Feb. 3, 2010



TEST CONFIGURATION
9kHz ~ 30MHz




                             3m
                                                                                       Loop antenna
      EUT

                                                                                    Spectrum /
                                                                                     Receiver


             Turntable                    1m
                           0.8m




  Reference ground plane



30MHz ~ 1 GHz

                                                                                     Antenna
                                                                                      tower


                             3m
                                                                                       Bilog antenna
      EUT
                                    4m
                                                                                    Spectrum /
                                                                                     Receiver


             Turntable                    1m
                           0.8m
                                                                                    Pre-amp




  Reference ground plane




                                                        Page 14
  This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


                   Report No: T100127102-RP1             FCC ID: E2K-P05G                   Date of Issue: Feb. 3, 2010




TEST PROCEDURE
1. The EUT is placed on a turntable, which is 0.8m above ground plane.
2. The turntable shall be rotated for 360 degrees to determine the position of maximum emission
   level.
3. EUT is set 3m away from the receiving antenna, which is varied from 1m to 4m to find out the
   highest emissions.
4. Maximum procedure was performed on the six highest emissions to ensure EUT compliance.
5. And also, each emission was to be maximized by changing the polarization of receiving antenna
   both horizontal and vertical.
6. Set the spectrum analyzer in the following setting as:
               RBW=100kHz / VBW=300kHz / Sweep=AUTO
7. Repeat above procedures until the measurements for all frequencies are complete.


TEST RESULTS
No non-compliance noted.




                                                         Page 15
   This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


                   Report No: T100127102-RP1             FCC ID: E2K-P05G                    Date of Issue: Feb. 3, 2010


TEST DATA
Operation Mode:              TX mode                        Test Date:                February 1, 2010
Temperature:                 18°C                           Tested by:                Alonso Lu
Humidity:                    60 % RH                        Polarity:                 Ver. / Hor.

                                                                Correction
Frequency      Ant.Pol.      Detector Mode Reading                                  Result  Limit 3m           Margin
                                                                 Factor
  (MHz)         (H/V)         (PK/QP/AVG) (dBuV)                                  (dBuV/m) (dBuV/m)             (dB)
                                                                 (dB/m)
   13.56            V               QP             34.53            9.59             44.12         123.99       -79.87
  37.2750           V               QP             41.60           -14.00            27.60         40.00        -12.40
  59.1000           V               QP             40.94           -15.48            25.46         40.00        -14.54
  83.3500           V               QP             49.24           -19.15            30.09         40.00         -9.91
 136.7000           V               QP             37.64           -12.95            24.69         43.50        -18.81
 267.6500           V               QP             41.78           -12.12            29.66         46.00        -16.34
 333.1250           V               QP             38.82           -10.16            28.66         46.00        -17.34
 364.6500           V               QP             41.51            -9.61            31.90         46.00        -14.10
 401.0250           V               QP             39.42            -9.45            29.97         46.00        -16.03
 432.5500           V               QP             42.83            -8.70            34.13         46.00        -11.87
 531.9750           V               QP             44.13            -6.51            37.62         46.00         -8.38

Remark:
   1. No emission found between lowest internal used / generated frequency to 30 MHz. (9kHz ~
      30MHz)
   2. Measuring frequencies from 9 kHz to the 1GHz.
   3. Radiated emissions measured in the measured frequency range were made with an
      instrument using peak detector or quasi-peak detector mode.
   4. Data of measurement within this frequency range shown “ --- ” in the table above means
      the reading of emissions are attenuated more than 20dB below the permissible limits or the
      field strength is too small to be measured.
   5. The IF bandwidth of SPA between 30MHz to 1GHz was 100kHz.
   6. Calculation by Converting 30m to 3meter limits.
      30m limit= 15848 (uV/m)
      **3m limit = 20*log(15848)+40log(30m/3m) (dBuV/m)
        = 84 + 40 (dBuV/m)
        = 124 (dBuV/m)




                                                         Page 16
   This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


                   Report No: T100127102-RP1               FCC ID: E2K-P05G                  Date of Issue: Feb. 3, 2010



                                                                Correction
Frequency      Ant.Pol.      Detector Mode Reading                                  Result  Limit 3m           Margin
                                                                 Factor
  (MHz)         (H/V)         (PK/QP/AVG) (dBuV)                                  (dBuV/m) (dBuV/m)             (dB)
                                                                 (dB/m)
   13.56           H                QP             36.01            9.59             45.60         123.99       -78.39
  39.7147          H                QP             35.11           -13.67            21.44         40.00        -18.56
 134.3235          H                QP             36.95           -13.45            23.50         43.50        -20.00
 143.9750          H                QP             36.42           -12.40            24.02         43.50        -19.48
 165.8000          H                QP             37.27           -13.41            23.86         43.50        -19.64
 265.2250          H                QP             45.83           -12.17            33.66         46.00        -12.34
 333.1250          H                QP             40.70           -10.16            30.54         46.00        -15.46
 364.6500          H                QP             40.34            -9.61            30.73         46.00        -15.27
 401.0250          H                QP             44.93            -9.45            35.48         46.00        -10.52
 432.5500          H                QP             43.97            -8.70            35.27         46.00        -10.73
 531.9750          H                QP             42.54            -6.51            36.03         46.00         -9.97
 798.7250          H                QP             36.02            -2.16            33.86         46.00        -12.14

Remark:
   1. No emission found between lowest internal used / generated frequency to 30 MHz. (9kHz ~
      30MHz)
   2. Measuring frequencies from 9 kHz to the 1GHz.
   3. Radiated emissions measured in the measured frequency range were made with an
      instrument using peak detector or quasi-peak detector mode.
   4. Data of measurement within this frequency range shown “ --- ” in the table above means
      the reading of emissions are attenuated more than 20dB below the permissible limits or the
      field strength is too small to be measured.
   5. The IF bandwidth of SPA between 30MHz to 1GHz was 100kHz.
   6. Calculation by Converting 30m to 3meter limits.
      30m limit= 15848 (uV/m)
      **3m limit = 20*log(15848)+40log(30m/3m) (dBuV/m)
        = 84 + 40 (dBuV/m)
        = 124 (dBuV/m)




                                                         Page 17
   This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


                  Report No: T100127102-RP1             FCC ID: E2K-P05G                   Date of Issue: Feb. 3, 2010


TEST PLOT FOR CHANNEL MASK




                                                        Page 18
  This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


                   Report No: T100127102-RP1             FCC ID: E2K-P05G                   Date of Issue: Feb. 3, 2010


7.2. FREQUENCY STABILITY
LIMIT
According to §15.207(e), the frequency tolerance of the carrier signal shall be maintained
within +/- 0.01% of the operating frequency over a temperature variation of –20 degrees to
+50 degrees C at normal supply voltage, and for a variation in the primary supply voltage
from 85% to 115% of the rated supply voltage at a temperature of 20 degrees C. For battery
operated equipment, the equipment tests shall be performed using a new battery.


TEST CONFIGURATION
Temperature and Voltage Measurement (under normal and extreme test conditions)


                                                  Temperature Chamber




 Spectrum Analyzer                                             EUT




                                               AC/DC Power supply



TEST PROCEDURE
  1. Place the EUT on the table and set it in the transmitting mode.
  2. Remove the antenna from the EUT and then connect a low loss RF cable from the
     antenna port to the spectrum analyzer.
  3. Set the environment into appropriate environment.
  4. Set the spectrum analyzer as RBW=1kHz, VBW = RBW, Span = 200kHz, Sweep =
     auto.
  5. Mark the peak frequency and measure the frequency tolerance using frequency
     counter function.
  6. Repeat until all the results are investigated.




                                                         Page 19
   This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


                   Report No: T100127102-RP1             FCC ID: E2K-P05G                   Date of Issue: Feb. 3, 2010


TEST RESULTS
No non-compliance noted


TEST DATA
Temperature Variations
                               Measured     Delta
  Temp.          Voltage                                       Tolerance          Limit         Result
                               Frequency Frequency
   (oC)           (VAC)                                           (%)             (±%)        (Pass/Fail)
                                 (MHz)      (Hz)
   -20                         13.560255           255          0.001881          ±0.01           Pass

   -10                         13.560286           286          0.002106          ±0.01           Pass

     0                         13.560255           255          0.001881          ±0.01           Pass

    10                         13.560225           225          0.001663          ±0.01           Pass
                   110
    20                         13.560225           225          0.001663          ±0.01           Pass

    30                         13.560195           195          0.001441          ±0.01           Pass

    40                         13.560195           195          0.001440          ±0.01           Pass

    50                         13.560195           195          0.001440          ±0.01           Pass


Voltage Variations
                               Measured     Delta
  Temp.          Voltage                                       Tolerance          Limit         Result
                               Frequency Frequency
   (oC)           (VAC)                                           (%)             (±%)        (Pass/Fail)
                                 (MHz)      (Hz)
                   93.5      13.56022545           225          0.001663          ±0.01           Pass

    20             110       13.56022545           225          0.001663          ±0.01           Pass

                  126.5      13.56022545           225          0.001663          ±0.01           Pass




                                                         Page 20
   This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


                   Report No: T100127102-RP1             FCC ID: E2K-P05G                   Date of Issue: Feb. 3, 2010


7.3. POWERLINE CONDUCTED EMISSIONS
LIMIT
For an intentional radiator which is designed to be connected to the public utility (AC) power
line, the radio frequency voltage that is conducted back onto the AC power line on any
frequency or frequencies within the band 150 kHz to 30 MHz shall not exceed 250
microvolts (The limit decreases linearly with the logarithm of the frequency in the range 0.15 MHz to
0.50 MHz). The limits at specific frequency range is listed as follows:

                                                                             Limits
      Frequency Range                                                       (dBµV)
           (MHz)
                                                     Quasi-peak                                 Average
           0.15 to 0.50                                66 to 56*                                56 to 46*
             0.50 to 5                                      56                                      46
               5 to 30                                      60                                      50
Compliance with this provision shall be based on the measurement of the radio frequency
voltage between each power line (LINE and NEUTRAL) and ground at the power terminals.

TEST CONFIGURATION
 See test photographs attached in Appendix I for the actual connections between EUT and
 support equipment.

TEST PROCEDURE
 1. The EUT was placed on a table, which is 0.8m above ground plane.
 2. Maximum procedure was performed on the six highest emissions to ensure EUT
    compliance.
 3. Repeat above procedures until all frequency measured were complete.

TEST RESULTS
The initial step in collecting conducted data is a spectrum analyzer peak scan of the
measurement range. Significant peaks are then marked as shown on the following data
page, and these signals are then quasi-peaked.




                                                         Page 21
   This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


                    Report No: T100127102-RP1            FCC ID: E2K-P05G                   Date of Issue: Feb. 3, 2010

TEST DATA
The initial step in collecting conducted data is a spectrum analyzer peak scan of the
measurement range. Significant peaks are then marked as shown on the following data
page, and these signals are then quasi-peaked.
Operation Mode:                 Normal Link                          Test Date:          February 1, 2010
Temperature:                    20°C                                 Tested by:          Bill Cheng
Humidity:                       58% RH

            QP          AV           Corr.       QP          AV          QP          AV          QP         AV
 Freq.
          Reading     Reading       factor     Result      Result       Limit       Limit      Margin     Margin Note
 (MHz)
          (dBuV)      (dBuV)         (dB)      (dBuV)      (dBuV)      (dBuV)      (dBuV)       (dB)       (dB)

 2.6964     34.69       26.98       9.75       44.44       36.73       56.00       46.00       -11.56      -9.27     L1
 2.8444     35.50       27.84       9.75       45.25       37.59       56.00       46.00       -10.75      -8.41     L1
 3.0550     36.69       28.79       9.75       46.44       38.54       56.00       46.00       -9.56       -7.46     L1
 3.2725     31.22       24.78       9.75       40.97       34.53       56.00       46.00       -15.03     -11.47     L1
 3.4988     33.39       26.30       9.75       43.14       36.05       56.00       46.00       -12.86      -9.95     L1
 3.6814     34.47       27.26       9.76       44.23       37.02       56.00       46.00       -11.77      -8.98     L1
 4.2739     33.11       27.02       9.79       42.90       36.81       56.00       46.00       -13.10      -9.19     L1

 0.8574     25.26       16.64       9.61       34.87       26.25       56.00       46.00       -21.13     -19.75     L2
 2.5805     32.64       24.59       9.74       42.38       34.33       56.00       46.00       -13.62     -11.67     L2
 2.8043     34.98       27.45       9.74       44.72       37.19       56.00       46.00       -11.28      -8.81     L2
 3.0294     35.50       28.07       9.74       45.24       37.81       56.00       46.00       -10.76      -8.19     L2
 3.6903     34.74       27.82       9.75       44.49       37.57       56.00       46.00       -11.51      -8.43     L2
 4.2957     35.08       28.13       9.78       44.86       37.91       56.00       46.00       -11.14      -8.09     L2
Remark:
      1. Measuring frequencies from 0.15 MHz to 30MHz.
      2. The emissions measured in frequency range from 0.15 MHz to 30MHz were made with an
         instrument using Quasi-peak detector and average detector.
      3. The IF bandwidth of SPA between 0.15MHz and 30MHz was 10kHz; the IF bandwidth of Test
         Receiver between 0.15MHz and 30MHz was 9kHz;
      4. L1 = Line One (Live Line) / L2 = Line Two (Neutral Line)




                                                         Page 22
   This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


                   Report No: T100127102-RP1             FCC ID: E2K-P05G                   Date of Issue: Feb. 3, 2010

Test Plots
Conducted emissions (Line 1)




Conducted emissions (Line 2)




                                                         Page 23
   This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.



Document Created: 2010-03-03 19:31:47
Document Modified: 2010-03-03 19:31:47

© 2024 FCC.report