Test Report (DTS-BT LE) rev3.pdf

FCC ID: E2K-E25W001

Test Report

Download: PDF
FCCID_4215482

                                                               FCC Test Report

                       Report No.: RF190103C22

                             FCC ID: E2K-E25W001

                       Test Model: E25W (Refer to item 3.1 for more details)

                 Received Date: Dec. 22, 2018

                         Test Date: Jan. 23 ~ Feb. 01, 2019

                     Issued Date: Feb. 01, 2019


                         Applicant: Dell Inc.

                          Address: One Dell Way Round Rock, TX 78682, USA


                        Issued By: Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch

                    Lab Address: No. 47-2, 14th Ling, Chia Pau Vil., Lin Kou Dist., New Taipei City, Taiwan
                                 (R.O.C.)
                  Test Location: No. 19, Hwa Ya 2nd Rd., Wen Hwa Vil., Kwei Shan Dist., Taoyuan City
                                 33383, TAIWAN (R.O.C.)
         FCC Registration / 788550 / TW0003
       Designation Number:




This report is for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted
only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this
report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product
unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you
provided to us. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence, provided,
however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time
shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Unless specific
mention, the uncertainty of measurement has been explicitly taken into account to declare the compliance or non-compliance to the specification.
This report should not be used by the client to claim product certification, approval, or endorsement by TAF or any government agencies.

Report No.: RF190103C22                                              Page No. 1 / 34                                            Report Format Version: 6.1.1


                                                                   Table of Contents
Release Control Record .................................................................................................................................. 4
1         Certificate of Conformity...................................................................................................................... 5
2         Summary of Test Results ..................................................................................................................... 6
    2.1      Measurement Uncertainty ................................................................................................................... 6
    2.2      Modification Record ............................................................................................................................ 6
3         General Information .............................................................................................................................. 7
    3.1      General Description of EUT ................................................................................................................ 7
    3.2      Description of Test Modes ................................................................................................................... 8
    3.2.1    Test Mode Applicability and Tested Channel Detail............................................................................. 9
    3.3      Duty Cycle of Test Signal .................................................................................................................. 10
    3.4      Description of Support Units .............................................................................................................. 11
    3.4.1    Configuration of System under Test ................................................................................................... 11
    3.5      General Description of Applied Standards ......................................................................................... 11
4         Test Types and Results ...................................................................................................................... 12
    4.1      Radiated Emission and Bandedge Measurement............................................................................. 12
    4.1.1    Limits of Radiated Emission and Bandedge Measurement .............................................................. 12
    4.1.2    Test Instruments ................................................................................................................................ 13
    4.1.3    Test Procedures................................................................................................................................. 14
    4.1.4    Deviation from Test Standard ............................................................................................................ 14
    4.1.5    Test Setup .......................................................................................................................................... 15
    4.1.6    EUT Operating Conditions................................................................................................................. 16
    4.1.7    Test Results ....................................................................................................................................... 17
    4.2      Conducted Emission Measurement .................................................................................................. 22
    4.2.1    Limits of Conducted Emission Measurement .................................................................................... 22
    4.2.2    Test Instruments ................................................................................................................................ 22
    4.2.3    Test Procedures................................................................................................................................. 23
    4.2.4    Deviation from Test Standard ............................................................................................................ 23
    4.2.5    Test Setup .......................................................................................................................................... 23
    4.2.6    EUT Operating Conditions................................................................................................................. 23
    4.2.7    Test Results ....................................................................................................................................... 24
    4.3      6dB Bandwidth Measurement ........................................................................................................... 26
    4.3.1    Limits of 6dB Bandwidth Measurement ............................................................................................. 26
    4.3.2    Test Setup .......................................................................................................................................... 26
    4.3.3    Test Instruments ................................................................................................................................ 26
    4.3.4    Test Procedure .................................................................................................................................. 26
    4.3.5    Deviation fromTest Standard ............................................................................................................. 26
    4.3.6    EUT Operating Conditions................................................................................................................. 26
    4.3.7    Test Result ......................................................................................................................................... 27
    4.4      Conducted Output Power Measurement........................................................................................... 28
    4.4.1    Limits of Conducted Output Power Measurement ............................................................................ 28
    4.4.2    Test Setup .......................................................................................................................................... 28
    4.4.3    Test Instruments ................................................................................................................................ 28
    4.4.4    Test Procedures................................................................................................................................. 28
    4.4.5    Deviation from Test Standard ............................................................................................................ 28
    4.4.6    EUT Operating Conditions................................................................................................................. 28
    4.4.7    Test Results ....................................................................................................................................... 28
    4.5      Power Spectral Density Measurement .............................................................................................. 29
    4.5.1    Limits of Power Spectral Density Measurement ............................................................................... 29
    4.5.2    Test Setup .......................................................................................................................................... 29
    4.5.3    Test Instruments ................................................................................................................................ 29
    4.5.4    Test Procedure .................................................................................................................................. 29
    4.5.5    Deviation from Test Standard ............................................................................................................ 29
    4.5.6    EUT Operating Condition .................................................................................................................. 29

Report No.: RF190103C22                                              Page No. 2 / 34                                             Report Format Version: 6.1.1


    4.5.7   Test Results ....................................................................................................................................... 30
    4.6     Conducted Out of Band Emission Measurement .............................................................................. 31
    4.6.1   Limits of Conducted Out of Band Emission Measurement ............................................................... 31
    4.6.2   Test Setup .......................................................................................................................................... 31
    4.6.3   Test Instruments ................................................................................................................................ 31
    4.6.4   Test Procedure .................................................................................................................................. 31
    4.6.5   Deviation from Test Standard ............................................................................................................ 31
    4.6.6   EUT Operating Condition .................................................................................................................. 31
    4.6.7   Test Results ....................................................................................................................................... 31
5       Pictures of Test Arrangements .......................................................................................................... 33
Appendix – Information of the Testing Laboratories ................................................................................. 34




Report No.: RF190103C22                                             Page No. 3 / 34                                             Report Format Version: 6.1.1


                                         Release Control Record


Issue No.             Description                                        Date Issued
RF190103C22           Original release                                   Feb. 01, 2019




Report No.: RF190103C22                     Page No. 4 / 34       Report Format Version: 6.1.1


1    Certificate of Conformity


            Product: MC Carrier Card

              Brand: DELL or Dell EMC

        Test Model: E25W (Refer to item 3.1 for more details)

    Sample Status: Engineering sample

          Applicant: Dell Inc.

          Test Date: Jan. 23 ~ Feb. 01, 2019

         Standards: 47 CFR FCC Part 15, Subpart C (Section 15.247)
                          ANSI C63.10:2013



The above equipment has been tested by Bureau Veritas Consumer Products Services (H.K.) Ltd.,
Taoyuan Branch, and found compliance with the requirement of the above standards. The test record, data
evaluation & Equipment Under Test (EUT) configurations represented herein are true and accurate accounts
of the measurements of the sample’s RF characteristics under the conditions specified in this report.




      Prepared by :                                               , Date:        Feb. 01, 2019
                             Celine Chou / Senior Specialist




     Approved by :                                                , Date:        Feb. 01, 2019
                             Bruce Chen / Project Engineer




Report No.: RF190103C22                         Page No. 5 / 34                       Report Format Version: 6.1.1


2      Summary of Test Results

                               47 CFR FCC Part 15, Subpart C (Section 15.247)
        FCC
                               Test Item                   Result                  Remarks
       Clause
                                                                    Meet the requirement of limit.
       15.207      AC Power Conducted Emission              Pass    Minimum passing margin is -8.34dB at
                                                                    0.28281MHz.
       15.205 /                                                     Meet the requirement of limit.
                   Radiated Emissions and Band Edge
       15.209 /                                             Pass    Minimum passing margin is -0.2dB at
                   Measurement
      15.247(d)                                                     7440.00MHz.
      15.247(d)    Antenna Port Emission                    Pass    Meet the requirement of limit.

    15.247(a)(2)   6dB bandwidth                            Pass    Meet the requirement of limit.

      15.247(b)    Conducted power                          Pass    Meet the requirement of limit.

      15.247(e)    Power Spectral Density                   Pass    Meet the requirement of limit.
                                                                  Antenna connector are SMA Male
       15.203      Antenna Requirement                      Pass  Reverse and IPEX not a standard
                                                                  connector.
Note: Determining compliance based on the results of the compliance measurement, not taking into account
      measurement instrumentation uncertainty.

2.1      Measurement Uncertainty
Where relevant, the following measurement uncertainty levels have been estimated for tests performed on
the EUT as specified in CISPR 16-4-2:
                                                                                 Expanded Uncertainty
                  Measurement                               Frequency
                                                                                         (k=2) (±)
      Conducted Emissions at mains ports                150kHz ~ 30MHz                    2.94 dB
                                                        30MHz ~ 200MHz                    3.63 dB
        Radiated Emissions up to 1 GHz
                                                       200MHz ~ 1000MHz                   3.64 dB
                                                         1GHz ~ 18GHz                     2.29 dB
        Radiated Emissions above 1 GHz
                                                         18GHz ~ 40GHz                    2.29 dB


2.2      Modification Record
There were no modifications required for compliance.




Report No.: RF190103C22                       Page No. 6 / 34                        Report Format Version: 6.1.1


3     General Information
3.1    General Description of EUT

 Product                    MC Carrier Card
 Brand                      DELL or Dell EMC
 Test Model                 E25W (Refer to note for more details)
 Sample Status              Engineering sample
 Power Supply Rating        12Vdc from Adapter
 Modulation Type            GFSK
 Transfer Rate              1Mbps
 Operating Frequency        2402 ~ 2480MHz
 Number of Channel          40
 Channel Spacing            2MHz
 Output Power               3.436mW
 Antenna Type               Dipole antenna with 2.0dBi gain
                            SMA Male Reverse for BT antenna
 Antenna Connector
                            IPEX for PCB Board
 Accessory Device           NA
 Cable Supplied             NA
Note:
1. All models are listed as below.
             Regulatory       Regulatory
   Brand                                                       Marketing Model                  DELL P/N
           Model Number Type Number
                                                            VEP 4600 Wi-Fi
                 E25W        E25W001       Contains FCC ID: TK4WLE600VX (for Wi-Fi module)       R6TM0
DELL or                                           FCC ID: E2K-E25W001 (for Bluetooth)
Dell EMC                                                     VEP 4600 LTE
                 E25W        E25W001         Contains FCC ID: N7NEM7455 (for LTE module)         WMTKC
                                                  FCC ID: E2K-E25W001 (for Bluetooth)
2. The EUT consumes power from the following adapter. (Support unit only)
 Brand                NETGEAR
 Model                MT12-Y120100-A1
 Input Power          100-120Vac, 60Hz, 0.3A
 Output Power         12Vdc, 1.0A
 Power Line           1.82m cable without core attached on adapter




Report No.: RF190103C22                      Page No. 7 / 34                     Report Format Version: 6.1.1


3.2   Description of Test Modes
40 channels are provided to this EUT:
  Channel      Freq. (MHz)   Channel    Freq. (MHz)     Channel   Freq. (MHz)   Channel      Freq. (MHz)
     0            2402         10          2422           20         2442         30            2462
     1            2404         11          2424           21         2444         31            2464
     2            2406         12          2426           22         2446         32            2466
     3            2408         13          2428           23         2448         33            2468
     4            2410         14          2430           24         2450         34            2470
     5            2412         15          2432           25         2452         35            2472
     6            2414         16          2434           26         2454         36            2474
     7            2416         17          2436           27         2456         37            2476
     8            2418         18          2438           28         2458         38            2478
     9            2420         19          2440           29         2460         39            2480




Report No.: RF190103C22                     Page No. 8 / 34                      Report Format Version: 6.1.1


3.2.1        Test Mode Applicability and Tested Channel Detail

 EUT Configure                      Applicable to
                                                                                                      Description
     Mode            RE1G       RE<1G           PLC         APCM
         -              √           √              √            √          -
Where         RE1G: Radiated Emission above 1GHz & Bandedge               RE<1G: Radiated Emission below 1GHz
              Measurement
              PLC: Power Line Conducted Emission                           APCM: Antenna Port Conducted Measurement


Note: The EUT had been pre-tested on the positioned of each 3 axis. The worst case was found when positioned on X-plane.


Radiated Emission Test (Above 1GHz):
     Pre-Scan has been conducted to determine the worst-case mode from all possible combinations
     between available modulations, data rates and antenna ports (if EUT with antenna diversity architecture).
     Following channel(s) was (were) selected for the final test as listed below.
  EUT Configure Mode          Available Channel             Tested Channel                Modulation Type            Data Rate (Mbps)
               -                    0 to 39                    0, 19, 39                         GFSK                       1


Radiated Emission Test (Below 1GHz):
     Pre-Scan has been conducted to determine the worst-case mode from all possible combinations
     between available modulations, data rates and antenna ports (if EUT with antenna diversity architecture).
     Following channel(s) was (were) selected for the final test as listed below.
  EUT Configure Mode          Available Channel             Tested Channel                Modulation Type            Data Rate (Mbps)
               -                    0 to 39                         0                            GFSK                       1


Power Line Conducted Emission Test:
     Pre-Scan has been conducted to determine the worst-case mode from all possible combinations
     between available modulations, data rates and antenna ports (if EUT with antenna diversity architecture).
     Following channel(s) was (were) selected for the final test as listed below.
  EUT Configure Mode          Available Channel             Tested Channel                Modulation Type            Data Rate (Mbps)
               -                    0 to 39                         0                            GFSK                       1


Antenna Port Conducted Measurement:
     This item includes all test value of each mode, but only includes spectrum plot of worst value of each
     mode.
     Pre-Scan has been conducted to determine the worst-case mode from all possible combinations
     between available modulations, data rates and antenna ports (if EUT with antenna diversity architecture).
     Following channel(s) was (were) selected for the final test as listed below.
  EUT Configure Mode          Available Channel             Tested Channel                Modulation Type            Data Rate (Mbps)
               -                    0 to 39                    0, 19, 39                         GFSK                       1


Test Condition:
        Applicable to            Environmental Conditions                      Input Power (System)                 Tested by
             RE1G                      21 deg. C, 71% RH                         120Vac, 60Hz                      Noah Chang
             RE<1G                      25 deg. C, 70% RH                         120Vac, 60Hz                       Luis Lee
              PLC                       25 deg. C, 70% RH                         120Vac, 60Hz                       Luis Lee
             APCM                       25 deg. C, 60% RH                         120Vac, 60Hz                       Alan Wu




Report No.: RF190103C22                                 Page No. 9 / 34                                       Report Format Version: 6.1.1


3.3   Duty Cycle of Test Signal
Duty cycle of test signal is < 98%.

Duty cycle = 0.417/0.626 = 0.666, Duty factor = 10 * log (1/0.666) = 1.76




Report No.: RF190103C22                       Page No. 10 / 34              Report Format Version: 6.1.1


3.4      Description of Support Units
The EUT has been tested as an independent unit together with other necessary accessories or support units.
The following support units or accessories were used to form a representative test configuration during the
tests.
 ID         Product           Brand                 Model No.           Serial No.            FCC ID                   Remarks
 A.        Notebook           Lenovo                  81A4             YD02TWF5        PPD-QCNFA435        -
 B.         Adapter          NETGEAR          MT12-Y120100-A1               NA                 NA          Provided by manufacturer
 C.         Test Jig           NA                      NA                   NA                 NA          Provided by manufacturer
Note: All power cords of the above support units are non-shielded (1.8m).


                                                                        Shielding
 ID           Descriptions               Qty.          Length (m)                    Cores (Qty.)                  Remarks
                                                                        (Yes/No)
 1.     Console cable                     1                  0.3           N              0         -
                                                                                                    Attached on adapter
 2.     DC cable                          1                 1.82            -             0
                                                                                                    Provided by manufacturer


3.4.1      Configuration of System under Test

                                      Test Jig (C)
                                                1
                       Notebook (A)
                                                                          EUT

                                                2
                        Adapter (B)




3.5      General Description of Applied Standards
The EUT is a RF Product. According to the specifications of the manufacturer, it must comply with the
requirements of the following standards:

FCC Part 15, Subpart C (15.247)
KDB 558074 D01 15.247 Meas Guidance v05r01
ANSI C63.10:2013

All test items have been performed and recorded as per the above standards.




Report No.: RF190103C22                                       Page No. 11 / 34                                 Report Format Version: 6.1.1


4       Test Types and Results
4.1     Radiated Emission and Bandedge Measurement
4.1.1    Limits of Radiated Emission and Bandedge Measurement
Radiated emissions which fall in the restricted bands must comply with the radiated emission limits specified
as below table. Other emissions shall be at least 20dB below the highest level of the desired power:


            Frequencies                        Field Strength                  Measurement Distance
               (MHz)                         (microvolts/meter)                      (meters)

            0.009 ~ 0.490                       2400/F(kHz)                              300
            0.490 ~ 1.705                       24000/F(kHz)                              30
            1.705 ~ 30.0                              30                                  30
               30 ~ 88                               100                                   3
              88 ~ 216                               150                                   3
              216 ~ 960                              200                                   3
             Above 960                               500                                   3
Note:
1.    The lower limit shall apply at the transition frequencies.
2.    Emission level (dBuV/m) = 20 log Emission level (uV/m).
3.    For frequencies above 1000MHz, the field strength limits are based on average detector, however, the
      peak field strength of any emission shall not exceed the maximum permitted average limits, specified
      above by more than 20dB under any condition of modulation.




Report No.: RF190103C22                       Page No. 12 / 34                        Report Format Version: 6.1.1


4.1.2   Test Instruments
  Description & Manufacturer   Model No.                     Serial No.          Cal. Date          Cal. Due
Test Receiver
                                  ESCI                        100424           Jan. 03, 2019     Jan. 02, 2020
ROHDE & SCHWARZ
Spectrum Analyzer
                                 FSP40                        100040           Sep. 25, 2018 Sep. 24, 2019
ROHDE & SCHWARZ
BILOG Antenna
                               VULB9168                      9168-155          Nov. 21, 2018     Nov. 20, 2019
SCHWARZBECK
HORN Antenna
                              BBHA 9120D                   9120D-1170          Nov. 25, 2018     Nov. 24, 2019
SCHWARZBECK
HORN Antenna
                               BBHA 9170                  BBHA9170241          Nov. 25, 2018     Nov. 24, 2019
SCHWARZBECK
Loop Antenna
                                HLA 6121                          45745        Jun. 14, 2018     Jun. 13, 2019
TESEQ
Preamplifier
Agilent                          8447D                     2944A10631          Aug. 08, 2018 Aug. 07, 2019
(Below 1GHz)
Preamplifier
KEYSIGHT                         83017A                    MY53270295          Jul. 02, 2018     Jul. 01, 2019
(Above 1GHz)
RF signal cable
                             SUCOFLEX 104            MY 13380+295012/04        Aug. 08, 2018 Aug. 07, 2019
HUBER+SUHNER
RF signal cable
                             SUCOFLEX 104           Cable-CH4-03 (250724)      Aug. 08, 2018 Aug. 07, 2019
HUBER+SUHNER
Software                     ADT_Radiated_
                                                                   NA               NA                 NA
BV ADT                         V7.6.15.9.5
Antenna Tower
                                MA 4000                       010303                NA                 NA
inn-co GmbH
Antenna Tower Controller
                                  AT100                    AT93021703               NA                 NA
BV ADT
Turn Table
                                 TT100                     TT93021703               NA                 NA
BV ADT
Turn Table Controller
                                 SC100                     SC93021703               NA                 NA
BV ADT
Boresight Antenna Fixture        FBA-01                     FBA-SIP01               NA                 NA
Pre-amplifier (18GHz-40GHz)
                              EMC184045B                      980175           Nov. 14, 2018     Nov. 13, 2019
EMC
                                                   MY55050005/MY5519000
USB Wideband Power Sensor
                                   U2021XA         4/MY55190007/MY55210 Jul. 17, 2018            Jul. 16, 2019
KEYSIGHT
                                                           005

Note: 1. The calibration interval of the above test instruments is 12 months and the calibrations are traceable
         to NML/ROC and NIST/USA.
      2. The test was performed in HwaYa Chamber 4.
      3. The FCC Designation Number is TW0003. The number will be varied with the Lab location and
         scope as attached.
      4. The IC Site Registration No. is 7450F-4.




Report No.: RF190103C22                        Page No. 13 / 34                        Report Format Version: 6.1.1


4.1.3   Test Procedures
For Radiated emission below 30MHz
a. The EUT was placed on the top of a rotating table 0.8 meters above the ground at a 3 meter chamber
    room. The table was rotated 360 degrees to determine the position of the highest radiation.
b.   The EUT was set 3 meters away from the interference-receiving antenna, which was mounted on the top
     of a variable-height antenna tower.
c.   Parallel, perpendicular, and ground-parallel orientations of the antenna are set to make the
     measurement.
d.   For each suspected emission, the EUT was arranged to its worst case and the rotatable table was turned
     from 0 degrees to 360 degrees to find the maximum reading.
e.   The test-receiver system was set to Quasi-Peak Detect Function and Specified Bandwidth with
     Maximum Hold Mode.
Note:
1. The resolution bandwidth and video bandwidth of test receiver/spectrum analyzer is 9kHz at frequency
    below 30MHz.


For Radiated emission above 30MHz
a. The EUT was placed on the top of a rotating table 0.8 meters (for 30MHz ~ 1GHz) / 1.5 meters (for above
    1GHz) above the ground at 3 meter chamber room for test. The table was rotated 360 degrees to
    determine the position of the highest radiation.
b.   The EUT was set 3 meters away from the interference-receiving antenna, which was mounted on the top
     of a variable-height antenna tower.
c.   The height of antenna is varied from one meter to four meters above the ground to determine the
     maximum value of the field strength. Both horizontal and vertical polarizations of the antenna are set to
     make the measurement.
d.   For each suspected emission, the EUT was arranged to its worst case and then the antenna was tuned
     to heights from 1 meter to 4 meters and the rotatable table was turned from 0 degrees to 360 degrees to
     find the maximum reading.
e.   The test-receiver system was set to quasi-peak detect function and specified bandwidth with maximum
     hold mode when the test frequency is below 1 GHz.
f.   The test-receiver system was set to peak and average detect function and specified bandwidth with
     maximum hold mode when the test frequency is above 1 GHz. If the peak reading value also meets
     average limit, measurement with the average detector is unnecessary.
Note:
1. The resolution bandwidth and video bandwidth of test receiver/spectrum analyzer is 120kHz for
    Quasi-peak detection (QP) at frequency below 1GHz.
2.   The resolution bandwidth of test receiver/spectrum analyzer is 1 MHz and the video bandwidth is 3 MHz
     for Peak detection (PK) at frequency above 1GHz.
3.   The resolution bandwidth of test receiver/spectrum analyzer is 1MHz and the video bandwidth is ≥ 1/T
     (Duty cycle < 98%) or 10Hz (Duty cycle ≥ 98%) for Average detection (AV) at frequency above 1GHz.
4.   All modes of operation were investigated and the worst-case emissions are reported.


4.1.4   Deviation from Test Standard
No deviation.




Report No.: RF190103C22                        Page No. 14 / 34                        Report Format Version: 6.1.1


4.1.5   Test Setup
For Radiated emission below 30MHz
                                                                     1m
              EUT&                        3m
              Support Units

                               Turn Table

                 80cm


                                       Ground Plane
                                       Test Receiver




For Radiated emission 30MHz to 1GHz
                                                        Ant. Tower
                                                                     1-4m
                                                                     Variable
                                           3m
                                          10m
              EUT&
              Support Units

                                    Turn Table

                  80cm


                                       Ground Plane

                                       Test Receiver




Report No.: RF190103C22                  Page No. 15 / 34              Report Format Version: 6.1.1


For Radiated emission above 1GHz
                                                               Ant. Tower            1-4m
                                                                                     Variable
              EUT&                               3m
              Support Units

                                      Turn Table
                                                      Absorber

                 150cm


                                              Ground Plane
                                              Test Receiver




For the actual test configuration, please refer to the attached file (Test Setup Photo).


4.1.6   EUT Operating Conditions

a. Set the EUT under transmission condition continuously at specific channel frequency.




Report No.: RF190103C22                         Page No. 16 / 34                           Report Format Version: 6.1.1


4.1.7   Test Results
Above 1 GHz Data:
CHANNEL                     TX Channel 0            DETECTOR                   Peak (PK)
FREQUENCY RANGE             1GHz ~ 25GHz            FUNCTION                   Average (AV)


                      ANTENNA POLARITY & TEST DISTANCE: HORIZONTAL AT 3 M
                    EMISSION                                               TABLE                   CORRECTION
                                    LIMIT                   ANTENNA                  RAW VALUE
NO. FREQ. (MHz)       LEVEL                  MARGIN (dB)                   ANGLE                     FACTOR
                                  (dBuV/m)                 HEIGHT (m)                  (dBuV)
                     (dBuV/m)                                             (Degree)                    (dB/m)
 1      2390.00       57.2 PK       74.0        -16.8            1.05 H      63         23.4           33.8
 2      2390.00       45.9 AV       54.0         -8.1            1.05 H     63          12.1           33.8
 3      *2402.00      86.3 PK                                    1.00 H      50         52.6           33.7
 4      *2402.00      85.2 AV                                    1.00 H      50         51.5           33.7
 5      4804.00       53.8 PK       74.0        -20.2            2.11 H     314         40.5           13.3
 6      4804.00       45.8 AV       54.0         -8.2            2.11 H     314         32.5           13.3
                          ANTENNA POLARITY & TEST DISTANCE: VERTICAL AT 3 M
                    EMISSION                                               TABLE                   CORRECTION
                                    LIMIT                   ANTENNA                  RAW VALUE
NO. FREQ. (MHz)       LEVEL                  MARGIN (dB)                   ANGLE                     FACTOR
                                  (dBuV/m)                 HEIGHT (m)                  (dBuV)
                     (dBuV/m)                                             (Degree)                    (dB/m)
 1      2390.00       57.9 PK       74.0        -16.1            1.77 V     12          24.1           33.8
 2      2390.00       46.3 AV       54.0         -7.7            1.77 V      12         12.5           33.8
 3      *2402.00      96.9 PK                                    1.72 V       9         63.2           33.7
 4      *2402.00      95.3 AV                                    1.72 V       9         61.6           33.7
 5      4804.00       57.5 PK       74.0        -16.5            1.70 V     142         44.2           13.3
 6      4804.00       50.7 AV       54.0         -3.3            1.70 V     142         37.4           13.3


Remarks:
           1. Emission Level(dBuV/m) = Raw Value(dBuV) + Correction Factor(dB/m)
           2. Correction Factor(dB/m) = Antenna Factor(dB/m) + Cable Factor(dB) – Pre-Amplifier Factor(dB)
           3. The other emission levels were very low against the limit
           4. Margin value = Emission Level – Limit value
           5. " * ": Fundamental frequency




Report No.: RF190103C22                       Page No. 17 / 34                        Report Format Version: 6.1.1


CHANNEL                     TX Channel 19           DETECTOR                   Peak (PK)
FREQUENCY RANGE             1GHz ~ 25GHz            FUNCTION                   Average (AV)


                      ANTENNA POLARITY & TEST DISTANCE: HORIZONTAL AT 3 M
                    EMISSION                                               TABLE                   CORRECTION
                                    LIMIT                   ANTENNA                  RAW VALUE
NO. FREQ. (MHz)       LEVEL                  MARGIN (dB)                   ANGLE                     FACTOR
                                  (dBuV/m)                 HEIGHT (m)                  (dBuV)
                     (dBuV/m)                                             (Degree)                    (dB/m)
 1     *2440.00       87.2 PK                                    1.00 H     343         53.4           33.8
 2     *2440.00       85.8 AV                                    1.00 H     343         52.0           33.8
 3     4880.00        53.7 PK       74.0        -20.3            1.71 H     161         40.5           13.2
 4     4880.00        43.2 AV       54.0        -10.8            1.71 H     161         30.0           13.2
                          ANTENNA POLARITY & TEST DISTANCE: VERTICAL AT 3 M
                    EMISSION                                               TABLE                   CORRECTION
                                    LIMIT                   ANTENNA                  RAW VALUE
NO. FREQ. (MHz)       LEVEL                  MARGIN (dB)                   ANGLE                     FACTOR
                                  (dBuV/m)                 HEIGHT (m)                  (dBuV)
                     (dBuV/m)                                             (Degree)                    (dB/m)
 1     *2440.00       96.0 PK                                    1.62 V      7          62.2           33.8
 2     *2440.00       94.6 AV                                    1.62 V      7          60.8           33.8
 3     4880.00        57.7 PK       74.0        -16.3            1.44 V     142         44.5           13.2
 4     4880.00        50.3 AV       54.0         -3.7            1.44 V     142         37.1           13.2


Remarks:
           1. Emission Level(dBuV/m) = Raw Value(dBuV) + Correction Factor(dB/m)
           2. Correction Factor(dB/m) = Antenna Factor(dB/m) + Cable Factor(dB) – Pre-Amplifier Factor(dB)
           3. The other emission levels were very low against the limit
           4. Margin value = Emission Level – Limit value
           5. " * ": Fundamental frequency




Report No.: RF190103C22                       Page No. 18 / 34                        Report Format Version: 6.1.1


CHANNEL                     TX Channel 39           DETECTOR                   Peak (PK)
FREQUENCY RANGE             1GHz ~ 25GHz            FUNCTION                   Average (AV)


                      ANTENNA POLARITY & TEST DISTANCE: HORIZONTAL AT 3 M
                    EMISSION                                               TABLE                   CORRECTION
                                    LIMIT                   ANTENNA                  RAW VALUE
NO. FREQ. (MHz)       LEVEL                  MARGIN (dB)                   ANGLE                     FACTOR
                                  (dBuV/m)                 HEIGHT (m)                  (dBuV)
                     (dBuV/m)                                             (Degree)                    (dB/m)
 1     *2480.00       88.1 PK                                    1.33 H     117         54.2           33.9
 2     *2480.00       86.7 AV                                    1.33 H     117         52.8           33.9
 3     2483.50        57.3 PK       74.0        -16.7            1.39 H     121         23.4           33.9
 4     2483.50        45.7 AV       54.0         -8.3            1.39 H     121         11.8           33.9
 5     4960.00        55.0 PK       74.0        -19.0            1.34 H     162         41.5           13.5
 6     4960.00        46.0 AV       54.0         -8.0            1.34 H     162         32.5           13.5
 7     7440.00        58.9 PK       74.0        -15.1            2.49 H     304         40.2           18.7
 8     7440.00        46.6 AV       54.0         -7.4            2.49 H     304         27.9           18.7
                          ANTENNA POLARITY & TEST DISTANCE: VERTICAL AT 3 M
                    EMISSION                                               TABLE                   CORRECTION
                                    LIMIT                   ANTENNA                  RAW VALUE
NO. FREQ. (MHz)       LEVEL                  MARGIN (dB)                   ANGLE                     FACTOR
                                  (dBuV/m)                 HEIGHT (m)                  (dBuV)
                     (dBuV/m)                                             (Degree)                    (dB/m)
 1     *2480.00       94.9 PK                                    2.31 V     34          61.0           33.9
 2     *2480.00       93.7 AV                                    2.31 V     34          59.8           33.9
 3     2483.50        57.5 PK       74.0        -16.5            2.33 V     56          23.6           33.9
 4     2483.50        46.9 AV       54.0         -7.1            2.33 V      56         13.0           33.9
 5     4960.00        55.5 PK       74.0        -18.5            1.04 V     81          42.0           13.5
 6     4960.00        47.5 AV       54.0         -6.5            1.04 V      81         34.0           13.5
 7     7440.00        63.3 PK       74.0        -10.7            3.57 V     207         44.6           18.7
 8     7440.00        53.8 AV       54.0         -0.2            3.57 V     207         35.1           18.7


Remarks:
           1. Emission Level(dBuV/m) = Raw Value(dBuV) + Correction Factor(dB/m)
           2. Correction Factor(dB/m) = Antenna Factor(dB/m) + Cable Factor(dB) – Pre-Amplifier Factor(dB)
           3. The other emission levels were very low against the limit
           4. Margin value = Emission Level – Limit value
           5. " * ": Fundamental frequency




Report No.: RF190103C22                       Page No. 19 / 34                        Report Format Version: 6.1.1


Below 1GHz worst-case data:
CHANNEL                    TX Channel 0            DETECTOR
                                                                              Quasi-Peak (QP)
FREQUENCY RANGE            9kHz ~ 1GHz             FUNCTION


                      ANTENNA POLARITY & TEST DISTANCE: HORIZONTAL AT 3 M
                    EMISSION                                              TABLE                   CORRECTION
                                   LIMIT                   ANTENNA                  RAW VALUE
NO. FREQ. (MHz)       LEVEL                 MARGIN (dB)                   ANGLE                     FACTOR
                                 (dBuV/m)                 HEIGHT (m)                  (dBuV)
                     (dBuV/m)                                            (Degree)                    (dB/m)
 1      51.24         28.5 QP      40.0        -11.5            2.00 H     113         37.5            -9.0
 2      144.38        30.4 QP      43.5        -13.1            2.00 H     274         39.4            -9.0
 3      223.94        28.7 QP      46.0        -17.3            1.50 H     76          39.7           -11.0
 4      342.30        27.7 QP      46.0        -18.3            1.00 H     329         35.1            -7.4
 5      730.38        34.9 QP      46.0        -11.1            1.50 H     30          34.5             0.4
 6      794.42        32.1 QP      46.0        -13.9            1.00 H     234         30.5             1.6


Remarks:
           1. Emission Level(dBuV/m) = Raw Value(dBuV) + Correction Factor(dB/m)
           2. Correction Factor(dB/m) = Antenna Factor(dB/m) + Cable Factor(dB) – Pre-Amplifier Factor(dB)
           3. The other emission levels were very low against the limit of frequency range 30MHz ~ 1000MHz
           4. Margin value = Emission Level – Limit value
           5. The emission levels were very low against the limit of frequency range 9kHz ~ 30MHz: the
              amplitude of spurious emissions attenuated more than 20 dB below the permissible value to be
              report




Report No.: RF190103C22                      Page No. 20 / 34                        Report Format Version: 6.1.1


CHANNEL                     TX Channel 0            DETECTOR
                                                                               Quasi-Peak (QP)
FREQUENCY RANGE             9kHz ~ 1GHz             FUNCTION


                          ANTENNA POLARITY & TEST DISTANCE: VERTICAL AT 3 M
                    EMISSION                                               TABLE                   CORRECTION
                                    LIMIT                   ANTENNA                  RAW VALUE
NO. FREQ. (MHz)       LEVEL                  MARGIN (dB)                   ANGLE                     FACTOR
                                  (dBuV/m)                 HEIGHT (m)                  (dBuV)
                     (dBuV/m)                                             (Degree)                    (dB/m)
 1      49.30         34.0 QP       40.0         -6.0            1.51 V     32          42.9            -8.9
 2      144.38        29.5 QP       43.5        -14.0            1.01 V     13          38.5            -9.0
 3      171.55        30.3 QP       43.5        -13.2            1.01 V     38          39.7            -9.4
 4      402.46        33.2 QP       46.0        -12.8            1.01 V     188         39.8            -6.6
 5      718.74        31.5 QP       46.0        -14.5            1.51 V     173         31.6            -0.1
 6      796.36        31.0 QP       46.0        -15.0            1.51 V      6          29.3             1.7


Remarks:
           1. Emission Level(dBuV/m) = Raw Value(dBuV) + Correction Factor(dB/m)
           2. Correction Factor(dB/m) = Antenna Factor(dB/m) + Cable Factor(dB) – Pre-Amplifier Factor(dB)
           3. The other emission levels were very low against the limit of frequency range 30MHz ~ 1000MHz
           4. Margin value = Emission Level – Limit value
           5. The emission levels were very low against the limit of frequency range 9kHz ~ 30MHz: the
              amplitude of spurious emissions attenuated more than 20 dB below the permissible value to be
              report




Report No.: RF190103C22                       Page No. 21 / 34                        Report Format Version: 6.1.1


4.2     Conducted Emission Measurement
4.2.1    Limits of Conducted Emission Measurement
                                                             Conducted Limit (dBuV)
        Frequency (MHz)
                                               Quasi-peak                               Average
          0.15 - 0.5                             66 - 56                                 56 - 46
          0.50 - 5.0                                 56                                     46
          5.0 - 30.0                                 60                                     50
Note: 1. The lower limit shall apply at the transition frequencies.
      2. The limit decreases in line with the logarithm of the frequency in the range of 0.15 to 0.50MHz.


4.2.2    Test Instruments

   Description & Manufacturer           Model No.                 Serial No.     Cal. Date          Cal. Due
Test Receiver
                                           ESCI                    100613      Dec. 10, 2018 Dec. 09, 2019
ROHDE & SCHWARZ
RF signal cable
                                          5D-FB              Cable-cond1-01    Sep. 05, 2018 Sep. 04, 2019
Woken
LISN
ROHDE & SCHWARZ                          ENV216                    101826      Feb. 26, 2018 Feb. 25, 2019
(EUT)
LISN
ROHDE & SCHWARZ                         ESH3-Z5                    100311      Aug. 19, 2018 Aug. 18, 2019
(Peripheral)
Software                             BV ADT_Cond_
                                                                     NA             NA                 NA
ADT                                     V7.3.7.4

Note: 1. The calibration interval of the above test instruments is 12 months and the calibrations are traceable
         to NML/ROC and NIST/USA.
      2. The test was performed in HwaYa Shielded Room 1.
      3. The VCCI Site Registration No. is C-2040.




Report No.: RF190103C22                        Page No. 22 / 34                        Report Format Version: 6.1.1


4.2.3   Test Procedures
a.   The EUT was placed 0.4 meters from the conducting wall of the shielded room with EUT being
     connected to the power mains through a line impedance stabilization network (LISN). Other support units
     were connected to the power mains through another LISN. The two LISNs provide 50 ohm/ 50uH of
     coupling impedance for the measuring instrument.
b.   Both lines of the power mains connected to the EUT were checked for maximum conducted interference.
c.   The frequency range from 150kHz to 30MHz was searched. Emission levels under (Limit - 20dB) was not
     recorded.
Note: The resolution bandwidth and video bandwidth of test receiver is 9kHz for quasi-peak detection (QP)
      and average detection (AV) at frequency 0.15MHz-30MHz.

4.2.4   Deviation from Test Standard
No deviation.


4.2.5   Test Setup
                                   Vertical Ground
                                   Reference Plane                               Test Receiver


                                   EUT
                      40cm




                                                        80cm
                      LISN



                                                                   Horizontal Ground
                                                                    Reference Plane

                          Note: 1.Support units were connected to second LISN.




For the actual test configuration, please refer to the attached file (Test Setup Photo).


4.2.6   EUT Operating Conditions
Same as 4.1.6.




Report No.: RF190103C22                         Page No. 23 / 34                           Report Format Version: 6.1.1


4.2.7   Test Results
                                                                                    Quasi-Peak (QP) /
Phase                            Line (L)                     Detector Function
                                                                                    Average (AV)

                           Corr.      Reading Value     Emission Level           Limit             Margin
           Freq.
 No                       Factor         [dB (uV)]         [dB (uV)]          [dB (uV)]             (dB)
           [MHz]          (dB)         Q.P.     AV.      Q.P.     AV.       Q.P.       AV.     Q.P.      AV.
  1       0.21250         9.72        40.56    32.13    50.28    41.85     63.11      53.11   -12.83 -11.26
  2       0.27891         9.73        40.06    26.07    49.79    35.80     60.85     50.85    -11.06 -15.05
  3       0.31797         9.74        36.97    25.84    46.71    35.58     59.76     49.76    -13.05 -14.18
  4       0.36875         9.75        33.28    20.71    43.03    30.46     58.53     48.53    -15.50 -18.07
  5       0.44297         9.74        31.35    20.31    41.09    30.05     57.01     47.01    -15.92 -16.96
  6       0.60313         9.73        32.50    21.10    42.23    30.83     56.00     46.00    -13.77 -15.17

Remarks:
               1. Q.P. and AV. are abbreviations of quasi-peak and average individually.
               2. The emission levels of other frequencies were very low against the limit.
               3. Margin value = Emission level - Limit value
               4. Correction factor = Insertion loss + Cable loss
               5. Emission Level = Correction Factor + Reading Value.




Report No.: RF190103C22                          Page No. 24 / 34                       Report Format Version: 6.1.1


                                                                                    Quasi-Peak (QP) /
Phase                            Neutral (N)                 Detector Function
                                                                                    Average (AV)

                           Corr.     Reading Value     Emission Level           Limit              Margin
           Freq.
 No                       Factor        [dB (uV)]         [dB (uV)]          [dB (uV)]               (dB)
           [MHz]          (dB)        Q.P.     AV.      Q.P.     AV.       Q.P.       AV.       Q.P.      AV.
  1       0.21250         9.73       42.37    32.54    52.10    42.27     63.11      53.11    -11.01 -10.84
  2       0.28281         9.74       42.65    28.34    52.39    38.08     60.73     50.73      -8.34    -12.65
  3       0.43906         9.75       32.30    19.43    42.05    29.18     57.08     47.08     -15.03 -17.90
  4       0.52891         9.74       31.75    21.22    41.49    30.96     56.00     46.00     -14.51 -15.04
  5       0.73594         9.73       29.54    17.51    39.27    27.24     56.00     46.00     -16.73 -18.76
  6       1.02344         9.72       26.06    14.96    35.78    24.68     56.00     46.00     -20.22 -21.32

Remarks:
               1. Q.P. and AV. are abbreviations of quasi-peak and average individually.
               2. The emission levels of other frequencies were very low against the limit.
               3. Margin value = Emission level - Limit value
               4. Correction factor = Insertion loss + Cable loss
               5. Emission Level = Correction Factor + Reading Value.




Report No.: RF190103C22                         Page No. 25 / 34                        Report Format Version: 6.1.1


4.3     6dB Bandwidth Measurement
4.3.1    Limits of 6dB Bandwidth Measurement
The minimum of 6dB Bandwidth Measurement is 0.5 MHz.


4.3.2    Test Setup


                                                      Spectrum
        EUT
                                 Attenuator           Analyzer


4.3.3    Test Instruments
Refer to section 4.1.2 to get information of above instrument.

4.3.4    Test Procedure
a.    Set resolution bandwidth (RBW) = 100kHz.
b.    Set the video bandwidth (VBW) ≥ 3 x RBW, Detector = peak.
c.    Trace mode = max hold.
d.    Sweep = auto couple.
e.    Measure the maximum width of the emission that is constrained by the frequencies associated with the
      two amplitude points (upper and lower) that are attenuated by 6 dB relative to the maximum level
      measured in the fundamental emission.


4.3.5    Deviation fromTest Standard
No deviation.


4.3.6    EUT Operating Conditions
The software provided by client to enable the EUT under transmission condition continuously at lowest,
middle and highest channel frequencies individually.




Report No.: RF190103C22                        Page No. 26 / 34                      Report Format Version: 6.1.1


4.3.7    Test Result
                                             6dB Bandwidth        Minimum Limit
        Channel           Frequency (MHz)                                                 Pass / Fail
                                                 (MHz)                (MHz)
          0                    2402                0.680               0.5                   Pass

          19                   2440                0.700               0.5                   Pass

          39                   2480                0.700               0.5                   Pass

                                       Spectrum Plot of Worst Value




Report No.: RF190103C22                      Page No. 27 / 34                     Report Format Version: 6.1.1


4.4        Conducted Output Power Measurement
4.4.1       Limits of Conducted Output Power Measurement
For systems using digital modulation in the 2400–2483.5 MHz bands: 1 Watt (30dBm)


4.4.2       Test Setup

                                                    Power Meter
           EUT                                       (Including
                                  Attenuator
                                                   Power Sensor)


4.4.3       Test Instruments
Refer to section 4.1.2 to get information of above instrument.

4.4.4       Test Procedures
A peak power sensor was used on the output port of the EUT. A power meter was used to read the response
of the peak power sensor. Record the power level.


4.4.5       Deviation from Test Standard
No deviation.


4.4.6       EUT Operating Conditions
Same as item 4.3.6.


4.4.7       Test Results

Channel Frequency (MHz) Peak Power (mW) Peak Power (dBm)             Limit (dBm)              Pass/Fail

      0             2402               3.436               5.36         30.00                   Pass

      19            2440               3.304               5.19         30.00                   Pass

      39            2480               3.184               5.03         30.00                   Pass




Report No.: RF190103C22                        Page No. 28 / 34                     Report Format Version: 6.1.1


4.5     Power Spectral Density Measurement
4.5.1    Limits of Power Spectral Density Measurement
The Maximum of Power Spectral Density Measurement is 8dBm.


4.5.2    Test Setup

                                                            Spectrum
         EUT
                                        Attenuator          Analyzer



4.5.3    Test Instruments
Refer to section 4.1.2 to get information of above instrument.

4.5.4    Test Procedure
a.    Set analyzer center frequency to DTS channel center frequency.
b.    Set the span to 1.5 times the DTS bandwidth.
c.    Set the RBW to: 3 kHz ≤ RBW ≤ 100 kHz.
d.    Set the VBW ≥ 3 × RBW.
e.    Detector = peak.
f.    Sweep time = auto couple.
g.    Trace mode = max hold.
h.    Allow trace to fully stabilize.
i.    Use the peak marker function to determine the maximum amplitude level within the RBW.


4.5.5    Deviation from Test Standard
No deviation.

4.5.6    EUT Operating Condition
Same as item 4.3.6




Report No.: RF190103C22                              Page No. 29 / 34              Report Format Version: 6.1.1


4.5.7     Test Results

        Channel           Freq. (MHz)       PSD (dBm/3kHz)       Limit (dBm/3kHz)         Pass / Fail

          0                  2402                 -2.71                8.00                  Pass

          19                 2440                 -2.97                8.00                  Pass

          39                 2480                 -3.18                8.00                  Pass

                                        Spectrum Plot of Worst Value




Report No.: RF190103C22                       Page No. 30 / 34                      Report Format Version: 6.1.1


4.6     Conducted Out of Band Emission Measurement
4.6.1    Limits of Conducted Out of Band Emission Measurement
Below -20dB of the highest emission level of operating band (in 100kHz Resolution Bandwidth).


4.6.2    Test Setup

                                                      Spectrum
        EUT
                                  Attenuator          Analyzer



4.6.3    Test Instruments
Refer to section 4.1.2 to get information of above instrument.

4.6.4    Test Procedure

MEASUREMENT PROCEDURE REF
a. Set the RBW = 100 kHz.
b. Set the VBW ≥ 300 kHz.
c. Detector = peak.
d. Sweep time = auto couple.
e. Trace mode = max hold.
f. Allow trace to fully stabilize.
g. Use the peak marker function to determine the maximum power level in any 100 kHz band segment
   within the fundamental EBW.

MEASUREMENT PROCEDURE OOBE
a. Set RBW = 100 kHz.
b. Set VBW ≥ 300 kHz.
c. Detector = peak.
d. Sweep = auto couple.
e. Trace Mode = max hold.
f. Allow trace to fully stabilize.
g. Use the peak marker function to determine the maximum amplitude level.


4.6.5    Deviation from Test Standard
No deviation.

4.6.6    EUT Operating Condition
Same as item 4.3.6


4.6.7    Test Results
The conducted emission test is performed on each TX port of operating mode without summing or adding
10log (N) since the limit is relative emission limit.
The spectrum plots are attached on the following pages. D1 line indicates the highest level, and D2 line
indicates the 20dB offset below D1. It shows compliance with the requirement.


Report No.: RF190103C22                        Page No. 31 / 34                     Report Format Version: 6.1.1


                                           CH 0




                                          CH 19




                                          CH 39




                    CH 0 Band edge                      CH 39 Band edge




Report No.: RF190103C22              Page No. 32 / 34             Report Format Version: 6.1.1


5     Pictures of Test Arrangements
Please refer to the attached file (Test Setup Photo).




Report No.: RF190103C22                        Page No. 33 / 34   Report Format Version: 6.1.1


Appendix – Information of the Testing Laboratories
We, Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch, were founded in 1988 to
provide our best service in EMC, Radio, Telecom and Safety consultation. Our laboratories are FCC
recognized accredited test firms and accredited and approved according to ISO/IEC 17025.

If you have any comments, please feel free to contact us at the following:

Lin Kou EMC/RF Lab                                    Hsin Chu EMC/RF/Telecom Lab
Tel: 886-2-26052180                                   Tel: 886-3-6668565
Fax: 886-2-26051924                                   Fax: 886-3-6668323

Hwa Ya EMC/RF/Safety Lab
Tel: 886-3-3183232
Fax: 886-3-3270892

Email: service.adt@tw.bureauveritas.com
Web Site: www.bureauveritas-adt.com

The address and road map of all our labs can be found in our web site also.



--- END ---




Report No.: RF190103C22                       Page No. 34 / 34                  Report Format Version: 6.1.1



Document Created: 2019-04-02 03:12:33
Document Modified: 2019-04-02 03:12:33

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC