Test Report

FCC ID: DWN-SITUOVIIRTS

Test Report

Download: PDF
FCCID_4135656

  Report on the Radio Testing

              For

SMK Electronics (Europe) Limited

               on

  Situo 5 Variation RTS Pure II

Report no. TRA-038923-45-02A

        28 March 2018




                                   RF915 4.0


Report Number:       TRA-038923-45-02A
Issue:               A




                               REPORT ON THE RADIO TESTING OF A
                                  SMK Electronics (Europe) Limited
                                   Situo 5 Variation RTS Pure II
                                WITH RESPECT TO SPECIFICATION
                                        FCC 47CFR 15.231



                                TEST DATE: 2018-02-08 to 2018-02-26




                                                                                   A Longley / A Tosif / A Wong
                                                                                   / I Broadwell
       Tested by:                                                                  Radio Test Engineers




                                                                                   A Tosif
      Written by:                                                                  Radio Test Engineer



                                           Digitally signed by John Charters
                                           DN: cn=John Charters, o, ou=Element
                                           Materials Technology Ltd.,
                                           email=john.charters@element.com, c=GB
                                           Reason: I am approving this document
                                                                                   J Charters
    Approved by:                           Date: 2018.09.25 08:45:55 +01'00'       Department Manager - Radio
             Date:                  28 March 2018




   Disclaimers:

   [1] THIS DOCUMENT MAY BE REPRODUCED ONLY IN ITS ENTIRETY AND WITHOUT CHANGE
   [2] THE RESULTS CONTAINED IN THIS DOCUMENT RELATE ONLY TO THE ITEM(S) TESTED


                                                  Report Number: TRA-038923-45-02A




1   Revision Record


Issue Number     Issue Date               Revision History
     A         28 March 2018   Original




                                                                        Page 3 of 23


                                                       Report Number: TRA-038923-45-02A




2   Summary
TEST REPORT NUMBER:           TRA-038923-45-02A


WORKS ORDER NUMBER:           TRA-038923-00


PURPOSE OF TEST:              Testing of radio frequency equipment per the
                              relevant authorization procedure of chapter 47 of
                              CFR (code of federal regulations) Part 2, subpart
                              J.

TEST SPECIFICATION(S):        47CFR15.231


EQUIPMENT UNDER TEST (EUT):   Situo 5 Variation RTS Pure II


FCC IDENTIFIER:               DWN-SITUOVIIRTS


MANUFACTURER/AGENT:           SMK Electronics (Europe) Limited


ADDRESS:                      Unit 6, Parsons Court
                              Welburn Way
                              Aycliffe Business Park
                              Newton Aycliffe
                              Co Durham
                              DL5 6ZE
                              Ireland


CLIENT CONTACT:               Nick Wass
                               07768 030151
                               nwass@smkeurope.com


ORDER NUMBER:                 105770


TEST DATE:                    2018-02-08 to 2018-02-26


TESTED BY:                    A Longley / A Tosif / A Wong / I Broadwell
                              Element




                                                                             Page 4 of 23


                                                                                    Report Number: TRA-038923-45-02A




2.1     Test Summary

                                                                            Applicable
                                                Requirement Clause
          Test Method and Description                                         to this       Result / Note
                                                     47CFR15
                                                                            equipment
      Deactivation and Period
                                                  15.231 (a)1,2 & 3                              Pass
      Transmission/Polling
      Field Strength of Fundamental and
                                                      15.231 (b)                                 Pass
      Spurious Emissions

      Occupied bandwidth                              15.231 (c)                                 Pass


      AC power line conducted emissions                15.207                                   Note 1


Specific Note:
   1. The EUT is a battery powered device.

General Notes:

The results contained in this report relate only to the items tested, in the condition at time of test, and were
obtained in the period between the date of initial receipt of samples and the date of issue of the report.

The apparatus was set up and exercised using the configurations, modes of operation and arrangements
defined in this report only. Any modifications made are identified in Section 8 of this report.

Particular operating modes, apparatus monitoring methods and performance criteria required by the
standards tested to have been performed except where identified in Section 5.2 of this test report
(Deviations from Test Standards).




                                                                                              Page 5 of 23


                                                                                                                      Report Number: TRA-038923-45-02A




3       Contents
1    Revision Record ................................................................................................................................ 3
2    Summary ........................................................................................................................................... 4
   2.1     Test Summary ........................................................................................................................... 5
3    Contents ............................................................................................................................................ 6
4    Introduction ....................................................................................................................................... 7
5    Test Specifications ............................................................................................................................ 8
   5.1     Normative References .............................................................................................................. 8
   5.2     Deviations from Test Standards ................................................................................................ 8
6    Glossary of Terms ............................................................................................................................. 9
7    Equipment under Test ..................................................................................................................... 10
   7.1     EUT Identification .................................................................................................................... 10
   7.2     System Equipment .................................................................................................................. 10
   7.3     EUT Mode of Operation .......................................................................................................... 10
     7.3.1      Transmission ................................................................................................................... 10
     7.3.2      Reception ........................................................................................................................ 10
   7.4     EUT Radio Parameters ........................................................................................................... 10
   7.5     EUT Description ...................................................................................................................... 10
8    Modifications ................................................................................................................................... 11
9    EUT Test Setup............................................................................................................................... 12
   9.1     Block Diagram ......................................................................................................................... 12
   9.2     General Set-up Photograph .................................................................................................... 12
10      General Technical Parameters.................................................................................................... 13
   10.1 Normal Conditions................................................................................................................... 13
   10.2 Varying Test Conditions .......................................................................................................... 13
11      Radiated emissions ..................................................................................................................... 14
   11.1 Definitions ............................................................................................................................... 14
   11.2 Test Parameters...................................................................................................................... 14
   11.3 Test Limit ................................................................................................................................ 14
   11.4 Test Method ............................................................................................................................ 15
   11.5 Test Set-up Photograph .......................................................................................................... 16
   11.6 Test Equipment ....................................................................................................................... 16
   11.7 Test Results ............................................................................................................................ 17
12      Occupied Bandwidth ................................................................................................................... 18
   12.1 Definition ................................................................................................................................. 18
   12.2 Test Parameters...................................................................................................................... 18
   12.3 Test Limit ................................................................................................................................ 18
   12.4 Test Method ............................................................................................................................ 18
   12.5 Test Equipment ....................................................................................................................... 18
   12.6 Test Results ............................................................................................................................ 19
13      Deactivation and Period Transmission/Polling ............................................................................ 20
   13.1 Test Parameters...................................................................................................................... 20
   13.2 Test Limit ................................................................................................................................ 20
   13.3 Test Method ............................................................................................................................ 20
   13.4 Test Equipment ....................................................................................................................... 20
   13.5 Test Results ............................................................................................................................ 21
14      Measurement Uncertainty ........................................................................................................... 22
15      General SAR test reduction & exclusion guidance ...................................................................... 23




                                                                                                                                                 Page 6 of 23


                                                                         Report Number: TRA-038923-45-02A




4    Introduction
This report TRA-038923-45-02A presents the results of the Radio testing on a SMK Electronics
(Europe) Limited, Situo 5 Variation RTS Pure II to specification 47CFR15 Radio Frequency
Devices.

The testing was carried out for SMK Electronics (Europe) Limited by Element, at the address
detailed below.


        Element Hull                                        Element Skelmersdale
        Unit E                                              Unit 1
        South Orbital Trading Park                          Pendle Place
        Hedon Road                                          Skemersdale
        Hull                                                West Lancashire
        HU9 1NJ                                             WN8 9PN
        UK                                                  UK


This report details the configuration of the equipment, the test methods used and any relevant
modifications where appropriate.

All test and measurement equipment under the control of the laboratory and requiring calibration is
subject to an established programme and procedures to control and maintain measurement
standards. The quality management system meets the principles of ISO 9001, and has quality
control procedures for monitoring the validity of tests undertaken. Records and sufficient detail are
retained to establish an audit trail of calibration records relating to its test results for a defined
period. Under control of the established calibration programme, key quantities or values of the test
& measurement instrumentation are within specification and comply with the relevant traceable
internationally recognised and appropriate standard specifications, which are UKAS calibrated as
such where these properties have a significant effect on results. Participation in inter-laboratory
comparisons and proficiency testing ensures satisfactory correlation of results conform to Elements
own procedures, as well as statistical techniques for analysis of test data providing the appropriate
confidence in measurements.

Throughout this report EUT denotes equipment under test.

FCC Site Listing:
Element is accredited for the above sites under the US-EU MRA, Designation number UK0009.

IC Registration Number:
Element Hull                     3483A

The test site requirements of ANSI C63.4-2014 are met up to 1GHz.

The test site SVSWR requirements of CISPR 16-1-4:2010 are met over the frequency range 1 GHz
to 18 GHz.




                                                                                               Page 7 of 23


                                                                      Report Number: TRA-038923-45-02A




5     Test Specifications

5.1       Normative References

          FCC 47 CFR Ch. I – Part 15 – Radio Frequency Devices.
          ANSI C63.10-2013 – American National Standard of Procedures for Compliance Testing of
           Unlicensed Wireless Devices.
          ANSI C63.4-2014 – American National Standard for Methods of Measurement of Radio-
           Noise Emissions from Low-Voltage Electrical and Electronic Equipment in the Range of 9
           kHz to 40 GHz.

5.2       Deviations from Test Standards

There were no deviations from the test standard.




                                                                                            Page 8 of 23


                                                                        Report Number: TRA-038923-45-02A




6   Glossary of Terms
§           denotes a section reference from the standard, not this document
AC          Alternating Current
ANSI        American National Standards Institute
BW          bandwidth
C           Celsius
CFR         Code of Federal Regulations
CW          Continuous Wave
dB          decibel
dBm         dB relative to 1 milliwatt
DC          Direct Current
DSSS        Direct Sequence Spread Spectrum
EIRP        Equivalent Isotropically Radiated Power
ERP         Effective Radiated Power
EUT         Equipment under Test
FCC         Federal Communications Commission
FHSS        Frequency Hopping Spread Spectrum
Hz          hertz
ITU         International Telecommunication Union
LBT         Listen before Talk
m           metre
max         maximum
MIMO        Multiple Input and Multiple Output
min         minimum
MRA         Mutual Recognition Agreement
N/A         Not Applicable
PCB         Printed Circuit Board
PDF         Portable Document Format
Pt-mpt      Point-to-multipoint
Pt-pt       Point-to-point
RF          Radio Frequency
RH          Relative Humidity
RMS         Root Mean Square
Rx          receiver
s           second
SVSWR       Site Voltage Standing Wave Ratio
Tx          transmitter
UKAS        United Kingdom Accreditation Service
V           volt
W           watt
Ω           ohm




                                                                                              Page 9 of 23


                                                                         Report Number: TRA-038923-45-02A




7     Equipment under Test

7.1       EUT Identification

          Name: Situo 5 Variation RTS Pure II
          Model Number/Type: RXT9000-9406E – Situo 5 variation RTS Pure II FCC
          Software Revision: Not Stated
          Build Level / Revision Number: Not Stated


7.2       System Equipment

Equipment listed below forms part of the overall test setup and is required for equipment
functionality and/or monitoring during testing. The compliance levels achieved in this report relate
only to the EUT and not items given in the following list.

Not Applicable – No support/monitoring equipment required.


7.3       EUT Mode of Operation

7.3.1      Transmission

The EUT was transmitting modulated carrier.


7.3.2      Reception

Not applicable. The EUT is a transmitter only device.


7.4       EUT Radio Parameters


Frequency of operation:                          433.42 MHz

Modulation type:                                 OOK

Channel bandwidth:                               224 kHz

Antenna type:                                    PCB trace antenna

Nominal Supply Voltage:                          3.0 Vdc



7.5       EUT Description

The EUT is a 433.42 MHz remote control transmitter used for controlling motorised blinds.




                                                                                              Page 10 of 23


                                                          Report Number: TRA-038923-45-02A




8   Modifications
No modifications were performed during this assessment.




                                                                               Page 11 of 23


                                                                     Report Number: TRA-038923-45-02A




9     EUT Test Setup

9.1    Block Diagram

The devices tested are standalone battery powered devices with no external connections.




                                           EUT




9.2    General Set-up Photograph




                                                                                          Page 12 of 23


                                                                         Report Number: TRA-038923-45-02A




10 General Technical Parameters

10.1 Normal Conditions

The EUT was tested under the normal environmental conditions of the test laboratory, except
where otherwise stated. The normal power source applied was 3 V dc from batteries.


10.2 Varying Test Conditions

There are no specific frequency stability requirements for the type of device. The results contained
in this report demonstrate that the occupied bandwidth is contained within the authorised band.

Variation of supply voltage is required to ensure stability of the declared output power. During
carrier power testing the following variations were made:


                        Category               Nominal                  Variation

                         Mains              110 V ac +/-2 %          85 % and 115 %


                         Battery              New battery                  N/A




                                                                                              Page 13 of 23


                                                                                    Report Number: TRA-038923-45-02A




11 Radiated emissions

11.1 Definitions
Spurious emissions
Emissions on a frequency or frequencies, which are outside the necessary bandwidth and the
level of which may be reduced without affecting the corresponding transmission of information.
Spurious emissions include harmonic emissions, parasitic emissions, intermodulation products
and frequency conversion products, but exclude out-of-band emissions.

Restricted bands
A frequency band in which intentional radiators are permitted to radiate only spurious emissions
but not fundamental signals.


11.2 Test Parameters
Test Location:                                    Element Hull
Test Chamber:                                     Wireless Lab 2
Test Standard and Clause:                         ANSI C63.10-2013, Clause 6.5 and 6.6
EUT Frequency Measured:                           433.42 MHz
Deviations From Standard:                         None
Measurement BW:                                   30 MHz to 1 GHz: 120 kHz; Above 1 GHz: 1 MHz
Measurement Detector:                             RMS average and Peak


Environmental Conditions (Normal Environment)

Temperature: 16 °C                                 +15 ºC to +35 ºC (as declared)
Humidity: 33 %                                     20 % RH to 75 % RH (as declared)
Supply: 3 Vdc                                      As declared

11.3 Test Limit
The limits on the field strength of the spurious emissions in the below table are based on the
fundamental frequency of the intentional radiator. Spurious emissions shall be attenuated to the
average (or, alternatively, CISPR quasi-peak) limits shown in this table or to the general limits
shown in § 15.209, whichever limit permits a higher field strength.

In addition, the field strength of emissions from intentional radiators shall not exceed the
following limits:

                                          Field strength of              Field strength of spurious
             Frequency
                                             fundamental                          emissions
               (MHz)
                                            (μV/m at 3 m)                       (μV/m at 3 m)
             40.66-40.70                        2,250                                225
               70-130                           1,250                                125
                                           1 1,250 to 3,750                      1 125 to 375
               130-174
               174-260                          3,750                                375
                                          1 3,750 to 12,500                     1 375 to 1,250
               260-470
              Above 470                         5,000                                500
1
    Linear interpolations
                                         General Spurious Limits
                            Frequency                              Field Strength
                               (MHz)                               (μV/m at 3 m)
                              30 to 88                                   100
                             88 to 216                                   150
                            216 to 960                                   200
                            Above 960                                    500




                                                                                                     Page 14 of 23


                                                                            Report Number: TRA-038923-45-02A




11.4 Test Method

With the EUT setup as per section 9 of this report and connected as per Figure i, the emissions
from the EUT were measured on a spectrum analyzer / EMI receiver.

Radiated electromagnetic emissions from the EUT are checked first by preview scans. Preview
scans for all spectrum and modulation characteristics are checked, using a peak detector and
where applicable worst-case determined for function, operation, orientation, etc. for both vertical
and horizontal polarisations. Pre-scan plots are shown with a peak detector and 100 kHz RBW.

If the EUT connects to auxiliary equipment and is table or floor standing, the configurations
prescribed in ANSI C63.10 are followed. Alternatively, a layout closest to normal use (as
declared by the provider) is employed, (see EUT setup photographs for more detail).

Emissions between 30 MHz and 1 GHz are measured using calibrated broadband antennas.
Emissions above 1 GHz are characterized using standard gain horn antennas. Pre-amplifiers
and filters are used where required. Care is taken to ensure that test receiver resolution
bandwidth, video bandwidth and detector type(s) meet the regulatory requirements.

For both horizontal and vertical polarizations, the EUT is then rotated through 360 degrees in
azimuth until the highest emission is detected. At the previously determined azimuth the test
antenna is raised and lowered from 1 to 4 m in height until a maximum emission level is
detected, this maximum value is recorded.

Power values measured on the test receiver / analyzer are converted to field strength, FS, in
dBμV/m at the regulatory distance, using:

                               FS = PR + CL + AF – PA + DC – CF

Where,
         PR is the power recorded on the receiver / spectrum analyzer in dBμV;
         CL is the cable loss in dB;
         AF is the test antenna factor in dB/m;
         PA is the pre-amplifier gain in dB (where used);
         DC is the duty correction factor in dB (where used, e.g. harmonics of pulsed
         fundamental);
         CF is the distance factor in dB (where measurement distance different to limit distance);

This field strength value is then compared with the regulatory limit.

Figure i Test Setup




                                                                                             Page 15 of 23


                                                                       Report Number: TRA-038923-45-02A




11.5 Test Set-up Photograph




11.6 Test Equipment

      Equipment                                   Equipment                  Element            Due For
        Type                  Manufacturer        Description                   No             Calibration
          ATS                   Rainford      Ferrite Lined Chamber           REF886           2018-07-24
      ESG E4438C                Agilent      Vector Signal Generator          REF844           2019-01-30
           310                  Sonoma       Pre-Amp (9kHz – 1GHz)            REF927           2018-06-30
         8449B                   Agilent     Pre-Amp (1 – 26.5GHz)            REF913           2020-02-07
          3115                   EMCO             Horn Antenna                RFG129           2020-02-12
        FSU50                     R&S          Spectrum Analyser               U544            2018-04-27
          3115                   EMCO             1-18GHz Horn                 L138            2018-04-13
       CBL6111B                  Chase            Bilog Antenna               REF2218          2019-11-06
        N9030A                  Agilent        Spectrum Analyser              REF2167          2018-08-17




                                                                                        Page 16 of 23


                                                                   Report Number: TRA-038923-45-02A




11.7 Test Results


                                                 Pre-
                     Meas’d    Cable   Antenna            Field           Field
           Freq.                                 amp                                      Limit
Detector            Emission   Loss     Factor          Strength        Strength
           (MHz)                                 Gain                                    (μV/m)
                     (dBμV)     (dB)    (dB/m)          (dBμV/m)         (μV/m)
                                                 (dB)
   Pk      433.4      61.9      1.9     22.6     N/A      86.4           20893.0         109750

   Av      433.4      55.9      1.9     22.6     N/A      80.4           10471.3          10975

   Pk      3900.0     54.3      3.8     32.1     35.3     54.9            555.9           5000

   Av      3900.0     46.2      3.8     32.1     35.3     46.8            218.8            500




                                                                                    Page 17 of 23


                                                                          Report Number: TRA-038923-45-02A




12 Occupied Bandwidth

12.1 Definition

20 dB bandwidth
The emission bandwidth (x dB) is defined as the frequency range between two points, one
above and one below the carrier frequency, at which the spectral density of the emission is
attenuated x dB below the maximum in-band spectral density of the modulated signal.


12.2 Test Parameters

Test Location:                               Element Hull
Test Chamber:                                Wireless Lab 2
EUT Frequency:                               433.42 MHz
Deviations From Standard:                    None
Measurement Detector:                        Peak

Environmental Conditions (Normal Environment)

Temperature: 21 °C                 +15 ºC to +35 ºC (as declared)
Humidity: 25 % RH                  20 % RH to 75 % RH (as declared)
Supply: 3 Vdc                      As declared



12.3 Test Limit

The bandwidth of the emission shall be no wider than 0.25% of the center frequency for devices
operating above 70 MHz and below 900 MHz. For devices operating above 900 MHz, the
emission shall be no wider than 0.5% of the center frequency. Bandwidth is determined at the
points 20 dB down from the modulated carrier.

12.4 Test Method

With the EUT connected as per Figure iii, the bandwidth of the EUT was measured on a
spectrum analyser.

Figure iii Test Setup




12.5 Test Equipment

      Equipment                                     Equipment         Element         Due For
        Type                Manufacturer            Description          No          Calibration
        FSU26                    R&S             Spectrum Analyser     REF909        2018-05-08




                                                                                           Page 18 of 23


                                                                                                     Report Number: TRA-038923-45-02A




12.6 Test Results

                                                            FCC 15.231
   Channel
                                FL                              FH               20 dB Bandwidth
  Frequency                                                                                                      Result
                              (MHz)                           (MHz)                   (kHz)
    (MHz)
    433.42                  433.417867                      433.425847                7.980                      PASS

                                                                  * RBW 300 Hz    Marker 1 [T1 ]
                                                                   VBW 1 kHz                -13.73 dBm
             Ref    0 dBm               * Att       25 dB          SWT 340 ms        433.421887077 MHz

             0                                                                    Delta 2 [T1 ]
                                                                                            -20.06   dB
                                                                                      -4.020000000   kHz   B
             -10                                              1
                                                                                  Delta 3 [T1 ]
      1 PK                                                                                  -20.11   dB
      MAXH
             -20                                                                       3.960000000   kHz



             -30                                2                         3
                      D1 -33.73 dBm

             -40



             -50                                                                                           EXT

                                                                                                           3DB
             -60



             -70



             -80



             -90


             -100

             Center   433.4219231 MHz                       3 kHz/                        Span   30 kHz




      Date: 22.FEB.2018     20:36:28




                                                                                                                      Page 19 of 23


                                                                            Report Number: TRA-038923-45-02A




13 Deactivation and Period Transmission/Polling

13.1 Test Parameters

Test Location:                                Element Hull
Test Chamber:                                 Wireless Lab 2
EUT Frequency:                                433.42 MHz
Deviations From Standard:                     None
Measurement Detector:                         Peak

Environmental Conditions (Normal Environment)

Temperature: 21 °C                  +15 ºC to +35 ºC (as declared)
Humidity: 25 % RH                   20 % RH to 75 % RH (as declared)
Supply: 3 Vdc                       As declared



13.2 Test Limit

A manually operated transmitter shall employ a switch that will automatically deactivate the
transmitter within not more than 5 seconds of being released.

A transmitter activated automatically shall cease transmission within 5 seconds after activation.

Periodic transmissions at regular predetermined intervals are not permitted. However, polling or
supervision transmissions, including data, to determine system integrity of transmitters used in
security or safety applications are allowed if the total duration of transmissions does not exceed
more than two seconds per hour for each transmitter. There is no limit on the number of
individual transmissions, provided the total transmission time does not exceed two seconds per
hour.

13.3 Test Method

With the EUT connected as per Figure iii, the bandwidth of the EUT was measured on a
spectrum analyser.

Figure iii Test Setup




13.4 Test Equipment

      Equipment                                      Equipment          Element         Due For
        Type                 Manufacturer            Description           No          Calibration
        FSU26                     R&S             Spectrum Analyser      REF909        2018-05-08




                                                                                             Page 20 of 23


                                                                                  Report Number: TRA-038923-45-02A




13.5 Test Results

   Activation Type                     Transmit Time               Limit                  Result
       Periodic                                    EUT does not use period transmissions
     Automatic                                   EUT does not use automatic transmissions
       Manual                             321 ms               < 5 Seconds                Pass

The EUT stopped transmitting immediately after the release of button, and didn’t transmit again
within 5 second.




In the above plot, marker 1 shows the button press, while maker 2 shows the button release.

The EUT was monitored for 2 hours in standby mode; no transmissions were observed during
this period.

                                                                  RBW 1 kHz
                                                                 * VBW 3 kHz
                       Ref   70 dBµV          * Att   10 dB       SWT 7200 s

                       70


                                                                                          A
                       60
                                                                                         SGL
              1 AV *
              CLRWR
                       50



                       40


                                                                                         PS
                       30



                       20

                                                                                         6DB
                       10                                                                AC



                       0



                       -10



                       -20


                       -30

                       Center 433.42 MHz                      720 s/




                                                                                                   Page 21 of 23


                                                                         Report Number: TRA-038923-45-02A




14 Measurement Uncertainty

Calculated Measurement Uncertainties

All statements of uncertainty are expanded standard uncertainty using a coverage factor of 1.96
to give a 95 % confidence:

[1] Radiated spurious emissions

Uncertainty in test result (30 MHz to 1 GHz) = 4.6 dB
Uncertainty in test result (1 GHz to 18 GHz) = 4.7 dB

[2] AC power line conducted emissions

Uncertainty in test result = 3.4 dB

[3] Occupied bandwidth

Uncertainty in test result = 15.5 %

[4] Conducted carrier power

Uncertainty in test result (Power Meter) = 1.08 dB

[5] Conducted / radiated RF power out-of-band

Uncertainty in test result – up to 8.1 GHz = 3.31 dB
Uncertainty in test result – 8.1 GHz to 15.3 GHz = 4.43 dB
Uncertainty in test result (30 MHz to 1 GHz) = 4.6 dB
Uncertainty in test result (1 GHz to 18 GHz) = 4.7 dB

[6] Power spectral density

Uncertainty in test result (Spectrum Analyser) = 2.48 dB




                                                                                          Page 22 of 23


                                                                        Report Number: TRA-038923-45-02A




15 General SAR test reduction & exclusion guidance
KDB 447498

Section 4.3 General SAR test reduction and exclusion guidance

For Standalone SAR exclusion consideration, when SAR Exclusion Threshold requirement in
KDB 447498 is satisfied, standalone SAR evaluation for general population exposure conditions
by measurement or numerical simulation is not required.
The SAR Test Exclusion Threshold for 100 MHz to 6 GHz will be determined as follows.
SAR Exclusion Threshold (SARET)             =      Step 1 + Step 2
Step 1
                        NT       =          [(MP/TSDA) * √ fGHz]


    NT = Numeric Threshold (3.0 for 1-g SAR and 7.5 for 10-g SAR)
    MP = Max Power of channel (mW) (including tune-up tolerance)
    TSDA = Min Test separation Distance or 50mm (whichever is lower) = 5mm (in this case)


We can transpose this formula to allow us to find the maximum power of a channel allowed and
compare this to the measured maximum power.
                        =        [(NT x TSDA) / √ fGHz]


For Distances greater than 50 mm Step 2 applies
Step 2
                                 (TSDB – 50mm) * 10
Where:
    TSDB          =     Min Test separation Distance (mm) = 50


Note: Step 2 doesn’t apply here as the TSDA is less than 50 mm


Operating Frequency 433.42 MHz
SARET             =     [(3.0 x 5) / √0.43342]
SARET             =     22.78 mW


 Channel Frequency               EIRP                  SAR Exclusion
                                                                            SAR Evaluation
      (MHz)                      (mW)                  Threshold (mW)

         433.42                      0.13                     22.78            Not Required

Note: EIRP is calculated from peak radiated field strength.




                                                                                         Page 23 of 23



Document Created: 2018-09-25 08:45:55
Document Modified: 2018-09-25 08:45:55

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC