MPE

FCC ID: DO4NEO-C

RF Exposure Info

Download: PDF
FCCID_3881051

Electromagnetic Compatibility Criteria for Intentional Radiators


        § 15.247(i)    Maximum Permissible Exposure



RF Exposure Requirements:      §1.1307(b)(1) and §1.1307(b)(2):         Systems operating under the
                               provisions of this section shall be operated in a manner that ensures
                               that the public is not exposed to radio frequency energy levels in excess
                               of the Commission’s guidelines.



RF Radiation Exposure Limit:   §1.1310: As specified in this section, the Maximum Permissible
                               Exposure (MPE) Limit shall be used to evaluate the environmental
                               impact of human exposure to radiofrequency (RF) radiation as specified
                               in Sec. 1.1307(b), except in the case of portable devices which shall be
                               evaluated according to the provisions of Sec. 2.1093 of this chapter.

Note:                          Co-located transmitters are:

                               8.2MHz RFID, 2.4GHz BT and 2.4GHz WiFi

                               OR

                               8..2MHz RFID, 2.4GHz BT and 1800MHz Cellular


                Equation from page 18 of OET 65, Edition 97-01



                         S = PG / 4R2    or     R = √(PG / 4S)



                where, S = Power Density (mW/cm2)

                         P = Power Input to antenna (mW)

                         G = Antenna Gain (numeric value)

                         R = Distance (cm)



                         G(dBi) = 10 log G (linear)



Test Results:

Results are based on KDB 447498 [Section 7.2]. Transmitters used in mobile device exposure conditions
for simultaneous transmission operations.

MPE Result for Intentional Radiators of Frequency Range: 300 MHZ – 1500 MHz

                                                                                Limit at
                Conduc                                                           20 cm
                          Conducte        Ant
Frequency         ted                                 Ant Gain   Power Density (mW/cm      Percentage of
                           d Power       Gain
  (MHz)         Power                                  (dBi)      (mW/cm^2)       ^2)        Limit (%)
                            (mW)         (dBi)
                 (dBm)
                                                                                 f/1500

   836
 (Cellular)     31.58      1438.79        1.8          1.513        0.393        0.557        70.55

Note: Tune Up Tolerance is [+/-] 1dB for 836 MHz radios.

The safe distance where Power Density is less than the MPE Limit listed above was found to be 21 cm.

Note: Cellular radio is pre-certified with FCC-ID: QISMS2372H-517


MPE Result for Intentional Radiators of Frequency Range: 1500 MHZ – 100,000 MHz

               Conduc                                                       Limit at
                          Conducte          Ant
Frequency        ted                               Ant Gain   Power Density  20 cm          Percentage of
                           d Power         Gain
  (MHz)        Power                                (dBi)      (mW/cm^2) (mW/cm               Limit (%)
                            (mW)           (dBi)
                (dBm)                                                         ^2)

2402 (BLE)      0.05        1.011          -4.1     0.389         0.00007            1          0.007

2437 (WiFi)     10.86       12.18            2      1.584         0.00384            1          0.384

Note: Tune Up Tolerance is [+/-] 1dB for 2402 MHz and 2437 MHz radios.

The safe distance where Power Density is less than the MPE Limit listed above was found to be 21 cm.

Note: BLE radio is pre-certified with FCC-ID: PANBT400 and WiFi radio is pre-certified with FCC-ID:
W6RRNWD-N1502UBE



MPE Result for Intentional Radiators of Frequency Range: 1.34 MHZ – 30 MHz

                         S = E / 4R2

                where, S = Power Density (mW/cm2)

                         E = EIRP (mW)

                         R = Distance (cm)


                                                                    Limit at 20 cm
Frequency       EIRP        EIRP                  Power Density      (mW/cm^2)           Percentage of
                                        EIRP (mW)
  (MHz)       (dBuV/m)     (dBm)                   (mW/cm^2)                               Limit (%)
                                                                        180/f2


    8.2         54.7       -40.5         0.0001    0.000000019           2.67             0.00000007

Note: Tune Up Tolerance is [+/-] 1dB for 8.2 MHz radio.

The safe distance where Power Density is less than the MPE Limit listed above was found to be 21 cm.



Document Created: 2018-06-06 09:36:53