users manual

FCC ID: DNY0B2L2C1900

Users Manual

Download: PDF
FCCID_386171

        Type Acceptance Test Report

             Multimode PCS Repeater
            FCC Rule Parts: 2, 15 & 24

  ACS Report Number: 03-0089-24TA
                  Manufacturer: EMS Wireless
                       Model: Link2Cell


                   Installation Guide




5015 B.U. Bowman Drive Buford, GA 30518 USA Voice: 770-831-8048 Fax: 770-831-8598


         Link2Cell™-19
      SOHO Signal Enhancer
Small Office – Home Office SIGNAL ENHANCER

      OPERATOR’S MANUAL




                               2850 Colonnades Court NW
                               Norcross, GA 30071
                               Phone: 770-582-0555
                               Fax: 770-729-0075
                               Email: www.emswireless.com


Preliminary Document                      Confidential                             EMS Wireless




Disclaimer

Every attempt has been made to make this material complete, accurate, and up-to-date. Users
are cautioned, however, that EMS Wireless reserves the right to make changes without notice
and shall not be responsible for any damages, including consequential, caused by reliance on
the material presented, including, but not limited to, typographical, arithmetical, or listing errors.



Copyright Information

© EMS Wireless

EMS Wireless
Norcross, Georgia




Link2CellTM-19                                                                                      2
Manual


Preliminary Document                     Confidential                            EMS Wireless




WARNINGS, CAUTIONS, AND GENERAL NOTES
        This product conforms to FCC Part 15. Changes or modifications not expressly approved
        by the party responsible for compliance could void the user's authority to operate the
        equipment.

         NOTE: This equipment has been tested and found to comply with the limits for a
         Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are
         designed to provide reasonable protection against harmful interference in a
         residential installation. This equipment generates, uses and can radiate radio
         frequency energy and, if not installed and used in accordance with the instructions,
         may cause harmful interference to radio communications. However, there is no
         guarantee that interference will not occur in a particular installation. If this equipment
         does cause harmful interference to radio or television reception, which can be
         determined by turning the equipment off and on, the user is encouraged to try to
         correct the interference by one or more of the following measures:

                  •    Reorient or relocate the receiving antenna.
                  •    Increase the separation between the equipment and receiver.
                  •    Connect the equipment into an outlet on a circuit different from that to
                       which the receiver is connected.
                  •    Consult the dealer or an experienced radio/TV technician for help.”


         In accordance with FCC regulations regarding human exposure to radiofrequency
         energy, this device shall be installed such that a minimum separation distance of
         20cm is maintained between it and general population.
         The antenna(s) used for this transmitter must not be co-located or operating in
          conjunction with any other transmitter.


         This Class B digital apparatus meets all requirements of the Canadian
         Interference Causing Equipment Regulations. Operation is subject to the
         following two conditions: (1) this device may not cause harmful interference, and (2)
         this device must accept any interference received, including interference that may
         cause undesired operation.

         Cet appareillage numérique de la classe B répond à toutes les exigences de
         l'interférence canadienne causant des règlements d'équipement. L'opération est
         sujette aux deux conditions suivantes: (1) ce dispositif peut ne pas causer
         l'interférence nocive, et (2) ce dispositif doit accepter n'importe quelle interférence
         reçue, y compris l'interférence qui peut causer l'opération peu désirée.




Link2CellTM-19                                                                                   3
Manual


Preliminary Document                     Confidential                           EMS Wireless


Safety Considerations

        When installing or using this product, observe all safety precautions during handling and
        operation. Failure to comply with the following general safety precautions and with
        specific precautions described elsewhere in this manual violates the safety standards of
        the design, manufacture, and intended use of this product. EMS Wireless assumes no
        liability for the customer's failure to comply with these precautions.




                                         WARNING
        WARNING        Calls attention to a procedure or practice, which if ignored, may result in
        damage to the system or system component. Do not perform any procedure preceded by a
        WARNING until described conditions are fully understood and met.


If You Need Help

        If you need additional copies of this manual, or have questions about system options, or
        need help with installation and using of the system, please contact EMS Wireless’ Sales
        Department.

                                   EMS Wireless Sales Dept.
                        2850 Colonnades Court NW, Norcross, GA 30071
                               Tel: 770 582 0555 Extension 5310




Link2CellTM-19                                                                                  4
Manual


Preliminary Document                        Confidential                          EMS Wireless


Service

          Do not attempt to modify or service any part of this product other than in accordance with
          procedures outlined in this Operator's Manual. If the product does not meet its warranted
          specifications, or if a problem is encountered that requires service, notify EMS Wireless’
          sales department. Service will be rendered according the EMS Wireless’ warranty and
          repair policy. The product shall not be returned without contacting EMS Wireless and
          obtaining a return authorization number from the Sales department

          When returning a product for service, include the following information: Owner, Model
          Number, Serial Number, Return Authorization Number (obtained in advance from EMS
          Wireless Customer Service Department), service required and/or a description of the
          problem encountered.


          The EMS Wireless Quality Plan includes product test and inspection operations to verify
          the quality and reliability of our products.


          EMS Wireless uses every reasonable precaution to ensure that every device meets
          published electrical, optical, and mechanical specifications prior to shipment. Customers
          are asked to advise their incoming inspection, assembly, and test personnel as to the
          precautions required in handling and testing ESD sensitive components. Physical
          damage to the external surfaces voids warranty.

          These products are covered by the following warranties:

          1.     General Warranty

                 EMS Wireless warrants to the original purchaser all standard products sold by
                 EMS Wireless to be free of defects in material and workmanship for the duration
                 of the warranty period of one (1) year from date of shipment from EMS Wireless.
                 During the warranty period, EMS Wireless’ obligation, at our option, is limited to
                 repair or replacement of any product that EMS Wireless proves to be defective.
                 This warranty does not apply to any product, which has been subject to
                 alteration, abuse, improper installation or application, accident, electrical or
                 environmental over-stress, negligence in use, storage, transportation or handling.

          2.     Specific Product Warranty Instructions

                 All EMS Wireless products are manufactured to high quality standards and are
                 warranted against defects in workmanship, materials and construction, and to no
                 further extent. Any claim for repair or replacement of a device found to be
                 defective on incoming inspection by a customer must be made within 30 days of
                 receipt of the shipment, or within 30 days of discovery of a defect within the
                 warranty period.

                 This warranty is the only warranty made by EMS Wireless and is in lieu of all
                 other warranties, expressed or implied, except as to title, and can be amended
                 only by a written instrument signed by an officer of EMS Wireless. EMS Wireless
                 sales agents or representatives are not authorized to make commitments on
                 warranty returns.

                 In the event that it is necessary to return any product against the above warranty,
                 the following procedure shall be followed:



Link2CellTM-19                                                                                    5
Manual


Preliminary Document                          Confidential                           EMS Wireless


                 a.       Return authorization shall be received from the EMS Wireless Customer
                          Service prior to returning any device. Advise the EMS Wireless Customer
                          Service of the model, serial number, and the discrepancy. The device
                          shall then be forwarded to EMS Wireless, transportation prepaid. Devices
                          returned freight collect or without authorization may not be accepted.

                 b.       Prior to repair, EMS Wireless Customer Service will advise the customer
                          of EMS Wireless test results and will advise the customer of any charges
                          for repair (usually for customer caused problems or out-of-warranty
                          conditions).

                          If returned devices meet full specifications and do not require repair, or if
                          non-warranty repairs are not authorized by the customer, the device may
                          be subject to a standard evaluation charge. Customer approval for the
                          repair and any associated costs will be the authority to begin the repair at
                          EMS Wireless. Customer approval is also necessary for any removal of
                          certain parts, such as connectors, which may be necessary for EMS
                          Wireless testing or repair.

                 c.       Repaired products are warranted for the balance of the original warranty
                          period, or at least 90 days from date of shipment.

        3.       Limitations of Liabilities

                 EMS Wireless’ liability on any claim of any kind, including negligence, for any
                 loss or damage arising from, connected with, or resulting from the purchase
                 order, contract, or quotation, or from the performance or breach thereof, or from
                 the design, manufacture, sale, delivery, installation, inspection, operation or use
                 of any equipment covered by or furnished under this contract, shall in no case
                 exceed the purchase price of the device which gives rise to the claim.

                 EXCEPT AS EXPRESSLY PROVIDED HEREIN, EMS WIRELESSMAKES NO
                 WARRANTY OF ANY KIND, EXPRESSED OR IMPLIED, WITH RESPECT TO ANY
                 GOODS, PARTS AND SERVICES PROVIDED IN CONNECTION WITH THIS
                 AGREEMENT INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF
                 MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.          EMS
                 WIRELESSSHALL NOT BE LIABLE FOR ANY OTHER DAMAGE INCLUDING, BUT
                 NOT LIMITED TO, INDIRECT, SPECIAL OR CONSEQUENTIAL DAMAGES ARISING
                 OUT OF OR IN CONNECTION WITH FURNISHING OF GOODS, PARTS AND
                 SERVICE HEREUNDER, OR THE PERFORMANCE, USE OF, OR INABILITY TO USE
                 THE GOODS, PARTS AND SERVICE.


                 EMS Wireless test reports or data indicating mean-time-to-failure, mean-time-
                 between-failure, or other reliability data are design guides and are not intended to
                 imply that individual products or samples of products will achieve the same
                 results. These numbers are to be used as management and engineering tools,
                 and are not necessarily indicative of expected field operation. These numbers
                 assume a mature design, good parts, and no degradation of reliability due to
                 manufacturing procedures and processes.




Link2CellTM-19                                                                                       6
Manual


Preliminary Document                  Confidential                         EMS Wireless


Handling the Link2Cell™ -19

1. Use ESD precautions when dealing with the modules within the Link2Cell™ -19 so that units
are not damaged.
2. Opening the unit voids warranty.
3. Disconnecting any component within the Link2Cell™-19 when powered can damage or destroy
the equipment and will void the warranty.




Link2CellTM-19                                                                            7
Manual


Preliminary Document                     Confidential                            EMS Wireless




                               Link2Cell™-19 Manual
Description

The Link2Cell™-19 SOHO, (Small Office-Home Office) Signal Enhancer, is a PCS band, bi-
directional amplifier unit and was designed to provide enhanced RF coverage for wireless
systems in small facilities. Usage includes providing coverage in retail stores, offices,
warehouses, restaurants, homes, etc.

The Link2Cell™-19 is housed in an indoor mountable enclosure, and is powered with a
regulated wall mountable power supply.

The Link2Cell™-19 supports all system protocols including CDMA, GSM/PCS1900 and
TDMA and a single model will cover all licensed 1.9 GHz PCS bands A through F. The
Link2Cell™-19 features Auto set-up, lightweight compact enclosure with internal antennas,
local alarming, and excellent electrical specifications, high reliability with cost effective
pricing.


Functionality

The Link2Cell™-19 is capable of automatically adjusting its own signal gain levels up to the
maximum output power levels. The Link2Cell™-19 detects the downlink output power and
adjusts the level for 2 dBm composite output power and continues to monitor and reset the
gain as required for proper system performance. For example, when CDMA protocol system
is being amplified, there could be an error in set up initially resulting from only pilot sync, and
paging Walsh codes being present on the RF carrier. The Link2Cell™-19 will reduce the
system gain until no signal is received that will exceed the output power setting. This
prevents the Link2Cell™-19 from setting up to a higher in power level than actually desired if
all of the Walsh codes were present. The gain does not continually change to maintain an
output power of 2 dBm AGC (Automatic Gain Control) since this would defeat the benefits
of power control in the service providers system.

The Link2Cell™ has 40 dB of gain control in the uplink and downlink signal paths. This
gain is controlled by a microprocessor that monitors the system operation on a real time basis.
The uplink and downlink attenuators are controlled by the internal microprocessor to adjust
for maximum gain in both paths. The uplink and dowlink signal paths are adjusted to the same
setting by the microprocessor unless the system determines this is not optimum for the units
operation.

Alarming

Alarming monitoring is accomplished in the Link2Cell™ by the microprocessor, which will
detect a failure in gain or a system oscillation. This is indicated to the user by a solid constant


Link2CellTM-19                                                                                    8
Manual


Preliminary Document                       Confidential                          EMS Wireless


Red indicator. User can try recycling the power which will allow the unit to go thru its
automatic set up operation but if the problem persists contact your service provider.

Indicators

The Link2Cell™-19 is equipped with three LED indicators on the end of the unit which
provide the following information:

During normal operation:
Indicator                      State                          Description

Green                          Off                            No DC Input Power Applied
                               Solid Indication               DC Power on, normal function
                               Flashing Indication            System Initialization, Auto Set Up

Red                            Flashing Indication            Warning, fault condition
                                                              (Unit will reset gain to stable
                                                              operation)
                               Solid Indication               Alarm
                                                              (Contact your Service Provider)


Amber                          Flashing Indication            No RF Signal Detected
                                                              (<-90 dBm)
                               Solid Indication               Weak RF Signal
                                                              (>-85 dBm)

Initial System Automatic Set Up:
(First 2-3 minutes of DC power being applied)

Indicator                      State                          Description

Green                          Flashing Indicator             System Initialization, Auto Set Up

Amber/Red                      Solid On, Both                 >76 dB Gain

Amber                          Solid On Indication            >73 dB Gain

Red                            Solid On Indication            >70 dB Gain

Amber/Red                      Flashing Both                  >67 dB Gain

Amber/Red                      Off, both                      <64 dB Gain

*Green Indicator will go to a solid indication once the initial set up is complete.



Link2CellTM-19                                                                                  9
Manual


Preliminary Document                    Confidential                           EMS Wireless




Primary Power

The Link2Cell™ Unit operates on 9 VDC input power @ 1 Amp. This is supplied with a
regulated wall mount supply, which is UL, and CSA listed. These are available to operate on
AC input voltage of 115 VAC.

Donor/Server Antenna

Internal donor and server antenna are each 13 dB nominal gain. The donor antenna must be
orientated to point in the direction of the Service Providers cell site location. Beam width of
the antennas is approximately 60 degrees wide so it is necessary for the antenna to point
toward the cell site. The indicators will provide a reference of the strongest RF power strength
when the antenna is located in the optimum location.




Link2CellTM-19                                                                                10
Manual


 Preliminary Document                           Confidential                                  EMS Wireless


Installation:
Note 1: The user is cautioned that modification or changes to this device not expressly approved by the party
responsible for compliance could void the user’s authority to operate this equipment.

Note 2: Manufacturer’s rated composite output power, individual channel power will vary depending on the
number of channels and distance from each cell site being received

Note 3: This device complies with Part 15 of the FCC Rules. Operation is subject to the condition that this
device does not cause harmful interference.

Introduction

Link2Cell™-19 is quick and easy to install, using a set of common tools. This section will
provide the basic steps to performing the installation of Link2Cell™ . Please read
complete instructions before beginning assembly.

Placement of the Unit
Unit must be positioned with the donor antenna facing the direction of the cell site and the
opposite side of the unit with LED indicators facing the intended coverage area. Signal
strength at this location should be adequate to make a call with the subscriber unit for the
SOHO, (Small Office-Home Office) signal enhancer to provide additional coverage and
service in the facility. (See optional mounting configurations in figure 2.)

 The signal enhancer provides improved signal performance by amplifying radio frequency
 signals being received from the base station and the subscriber unit (mobile phone). The
 model Link2Cell™ provides signal enhancement for the entire PCS band only, see the
 Link2Cell specifications for details on equipment.

 Link2Cell™ is designed to automatically set up its own gain and will improve performance
 in most applications as long as a signal is received at the window location. Actual area of
 coverage that will be improved will vary depending on the signal level received, and blockage
 to the signals in the desired area of coverage. Blockages to RF signals include walls, people,
 equipment and furniture, etc. Amount of signal attenuation by each of these blockages will
 vary depending upon their size and composition.

 If additional area of coverage is required, additional Link2Cell™ units can be cascaded inside
 of the facility to provide this. There is a practical limit to the number of signal enhancers that
 can be cascaded and provide enhanced system performance. If greater than three total
 Link2Cell units are required you should call your system provider for additional solutions
 that are available.




 Link2CellTM-19                                                                                                 11
 Manual


Preliminary Document                          Confidential                              EMS Wireless




Getting Started:

Unpack all of the boxes and insure all of the material is included for your installation
requirements and undamaged in shipment.

                       Quantity                  Part Description
                          1          Link2Cell™ SOHO Signal Enhancer
                          1          Loctite Thread locker
                          1          Power Converter
                          1          Mounting Base
                          2          Mounting Posts
                          4          Wall Anchors
                          4          Mounting Screws




                                                     Link2Cell Repeater



                                                             LOCTITE Threadlocker




                                                                          Power Converter



                                                                             Mounting Base



                       Mounting Posts (2)

                                  Wall Anchors (4)

                                       Mounting Screws (4)



                                                 Figure 1
                                            Package Contents




Link2CellTM-19                                                                                         12
Manual


    Preliminary Document                   Confidential                         EMS Wireless




                      Link2Cell™-19 Unit Orientation & Installation

Link2Cell™ is designed for optimum use as an in-door signal enhancer. The housing is
not weather resistant and the automatic set up procedure assumes sufficient isolation
between antennas. Since the Link2Cell™ has a total of 53 dB active gain and an
isolation of 73 dB must be obtained between the internal donor and the server antenna.
Should adequate isolation not be obtained the unit will automatically reduce its gain until
adequate isolation is obtained for the unit to operate properly. Isolation between the
antennas is reduced by several conditions near or around the antennas, metal or
conductive material, and movement of people near the antennas.


                                    Mounting the Link2Cell™-19

Link2Cell™-19 must be mounted so the Donor antenna is orientated to receive and transmit to
the cell site. The Donor antenna is located on the opposite side of the unit of the LED
indicators of the Link2Cell™-19 with the LED’s either at the bottom or the top to keep the
orientation of the Donor antenna correct with respect to the direction of the cell site and which
wall you desire to mount the unit on. 9 VDC input is located on the side of the Link2Cell™-
19 housing shown above.

The Link2Cell™-19 may also sit on top of a book case, cabinet or on the floor as long as
adequate signal is received by the unit to provide the desired coverage enhancement. As was
previously discussed, these cabinets and bookcases should not be metal since this will effect
the performance of the unit.




                           OR                                             OR
                                                                                                           Plug Power Converter
                                                                                                           into Unit

.
                                                                                    Plug Power Converter
                                                                                    into 110V Outlet



          Vertical Mounting Surfaces                          Horizontal Mounting Surfaces


                                              Figure 2

                                Optional Mounting Configurations




    Link2CellTM-19                                                                                         13
    Manual


Preliminary Document                           Confidential                 EMS Wireless


-Select the window that provides the strongest signal strength from the cell site to your
portable phone by viewing the number of bars displayed on the face of the phone.

- Select the location in the window that provides the strongest signal strength from the
cell site to your portable phone which will indicate how to position the Link2Cell™
(donor antenna) signal enhancer unit

-Remove the 2 protective caps of the mounting holes from the selected side of the
Link2Cell™, taking into consideration the 3 LED’s must be facing you or the desired
area of coverage.




                 Remove Protective Caps from
                 Mounting Holes




-Apply Loctite to the threads of the mounting posts and install (hand tighten only) into
the open mounting holes of Link2Cell™ unit.




         Apply LOCTITE to Threads of Mounting Posts
         in Accordance with Manufacturers Instructions
         and Install into Link2Cell Unit.
         Hand-Tighten Only




Link2CellTM-19                                                                              14
Manual


Preliminary Document                    Confidential                               EMS Wireless


-Attach Mounting Base (with the open U potion in an upward ? position) to the selected
position mounting surface area using the appropriate mounting hardware, (4 Wall
anchors and 4 mounting screws).




                                                       Slide Link2Cell Unit
                                                       into Mounting Base




                       Attach Mounting Base to Mounting Surface
                       Using Appropriate Mounting Hardware


-In a downward ? sliding motion, hook the Link2Cell™ Unit onto the secured mounting
base.


-Connect the Power Converter into the Link2Cell™ unit and the plug power converter
into an 110V outlet.




                                                            Plug Power Converter
                                                            into Unit




                                 Plug Power Converter
                                 into 110V Outlet




Link2CellTM-19                                                                                    15
Manual


Preliminary Document                             Confidential                           EMS Wireless


IMPORTANT: Before performing any maintenance or changing the position or location of
the unit, make sure power plug is removed from the 110 AC wall socket. Once the unit is
repositioned, the power should be plugged into the 110 wall socket, this will insure the unit is
set to maximum gain and performance.


System Set Up Instructions:

-After installing unit, apply power and Link2Cell™ unit will automatically set up. The
system initialization will require 1 – 2 minutes for setup completion.

-Note: Since the Link2Cell™ is a broadband unit, it will improve the service for all
system providers with cell sites in the direction the donor antenna is positioned.

Specifications for Model: Link2Cell™-19
Downlink Operating Frequency,                  MHz      1930 to 1990
Uplink Operating Frequency,                    MHz      1850 to 1910
Downlink EIRP Transmit Power                   dBm      15
Uplink EIRP Transmit Power                     dBm      28
System Gain                                    dB       40 to 79
Gain Flatness                                  dB       +/− 2
Noise Figure                                   dB       ≤6
Spurious Output @ Rated Power
          FCC Regulations                     dB        ≤ -13
          @Fc +/− 885 KHz (CDMA only)         dBc       ≤ 45
          @Fc +/− 1.25 MHz                    dBc       ≤ 26
          2 tone @ -1 dBm each, DL            dBc       ≤ 60
1 dB Compression                              dBm       UL 22, DL 22
IP3                                           dBm       UL 41, DL 41
Operating Temperature, degrees                C         0° to +50°
Power Source:                                            (115 VAC) 9 VDC@ 1 amp, External AC to DC
Mechanical Dimensions, H x W x D,             inches    14.25 x 14.25 x 6.0
MTBF                                           hours    80,000
Indicators, Green LED                                   Solid, Normal Operation
             Red LED                                    Flashing, Signal Overdrive
                                                        Solid, Auto Off, Contact Service Provider
             Yellow LED                                 Flashing, No Signal Detected, ≤ 90 dB
                                                        Solid, Weak Signal, ≤ 85 dB
Automatic System Set Up                                 Upon Power Up
   System Gain Indications upon Power Up                Green, Flashing during set up
   For first 3 minutes                                  Amber/Red ≥ 76 dB Solid
                                                        Amber         ≥ 73 dB Solid
                                                        Red           ≥ 70 dB Solid
                                                        Amber/Red ≥ 67 dB Flashing
                                                        Both OFF      = 64 dB
Certifications,                                         FCC, UL, CSA
*Meets or exceeds the EIA/TIA system requirements for
CDMA, TDMA or GSM system protocols.




Link2CellTM-19                                                                                         16
Manual


 Preliminary Document                      Confidential                             EMS Wireless




Trouble Shooting:

The Link2Cell™-19 has no field replaceable parts; repair is limited to improper mounting
location with respect to the cell site, insufficient RF signal levels, and installation or defective
units.

            Problem                          Check                         Corrective Action
 No Power                          Power Source                      Reconnect or repair
                                   Power Source OK                   Replace Unit
 Alarm Indication                                                    Recycle AC Power
                                   No change                         Replace Unit
 Amber Flashing                    No RF signal Detected             Recycle AC Power
                                   No Change                         Check Antenna alignment
                                                                     with cell site
                                   No Change                         Replace Unit
 Amber Solid Indicator             Weak RF Signal                    New Installation, Check
                                                                     Antenna alignment with cell
                                                                     site and recycle power
                                   Weak RF Signal                    Previously working, recycle
                                                                     power.
                                   No Change                         Replace Unit
 Green Flashing Indication                                           Unit is in initial system
                                                                     initialization, if still flashing
                                                                     after 5 minutes replace unit
 No signal improvement to          Recycle power to unit             Watch indicators for gain
 subscriber unit                                                     settings.
                                   Gain Settings, Amber or           OK, check antenna alignment
                                   Amber/red                         with cell site.
                                   Red, amber/red solid or           Insufficient isolation between
                                   flashing, or off                  antennas in the unit possibly.
                                                                     Move unit and try again.
                                                                     Unit operation can be
                                                                     effected if placed to close to
                                                                     metal objects or equipment.
                                   No Change                         Consult your Service
                                                                     Provider

For Customer Service Call, Tel: 770 583-0555 Extension 5310




 Link2CellTM-19                                                                                     17
 Manual



Document Created: 2003-07-23 10:19:13
Document Modified: 2003-07-23 10:19:13

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC