Test Report

FCC ID: DI2RCMHL

Test Report

Download: PDF
FCCID_257314

                                                                                 Computime Limited


                                                                                  Application
                                                                                     For
                                                                                 Certification
                                                                            (FCC ID: DI2RCMHL)

                                                                                            Transmitter




WO# 0207989
WL/Sandy
July 8, 2002




•   The test results reported in this test report shall refer only to the sample actually tested and shall not refer or be deemed to refer to bulk from which such a sample may be said to have been
    obtained.


•   This report shall not be reproduced except in full without prior authorization from Intertek Testing Services Hong Kong Limited.


•   For Terms And Conditions of the services, it can be provided upon request.




                                                             Intertek Testing Services Hong Kong Ltd.
                                                               2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong.
                                                                         Tel: (852) 2173 8888 Fax: (852) 2785 5487


                         INTERTEK TESTING SERVICES


                                LIST OF EXHIBITS


                   INTRODUCTION

                   EXHIBIT 1:             General Description

                   EXHIBIT 2:             System Test Configuration

                   EXHIBIT 3:             Emission Results

                   EXHIBIT 4:             Equipment Photographs

                   EXHIBIT 5:             Product Labelling

                   EXHIBIT 6:             Technical Specifications

                   EXHIBIT 7:             Instruction Manual

                   EXHIBIT 8:             Miscellaneous Information




FCC ID: DI2RCMHL
                                                                      i


                                 INTERTEK TESTING SERVICES

                                MEASUREMENT/TECHNICAL REPORT

                            Computime Limited - MODEL: Ambient RCMHL
                                       FCC ID: DI2RCMHL

                                                 July 8, 2002




      This report concerns (check one:)          Original Grant X      Class II Change

      Equipment Type: Low Power Transmitter (example: computer, printer, modem, etc.)



      Deferred grant requested per 47 CFR 0.457(d)(1)(ii)?             Yes                   No X

                                                             If yes, defer until:
                                                                                          date
      Company Name agrees to notify the Commission by:
                                                   date

      of the intended date of announcement of the product so that the grant can be issued on that
      date.

      Transition Rules Request per 15.37?                                           Yes             No X

      If no, assumed Part 15, Subpart C for intentional radiator - the new 47 CFR [12-18-01 Edition]
      provision.

      Report prepared by:                                              Wilson Loke
                                                                       Intertek Testing Services
                                                                       2/F., Garment Center,
                                                                       576, Castle Peak Road,
                                                                       HONG KONG
                                                                       Phone: 852-2173-8575
                                                                       Fax:     852-2371-0521




FCC ID: DI2RCMHL
                                                                                                           ii


                                             INTERTEK TESTING SERVICES



                                                          Table of Contents

1.0 General Description .................................................................................................................. 2
  1.1 Product Description .............................................................................................................. 2
  1.2 Related Submittal(s) Grants.................................................................................................... 2
  1.3 Test Methodology ................................................................................................................. 3
  1.4 Test Facility ......................................................................................................................... 3

2.0 System Test Configuration.......................................................................................................... 5
  2.1 Justification.......................................................................................................................... 5
  2.2 EUT Exercising Software....................................................................................................... 5
  2.3 Special Accessories ............................................................................................................... 5
  2.4 Equipment Modification ......................................................................................................... 6
  2.5 Measurement Uncertainty ...................................................................................................... 6
  2.6 Support Equipment List and Description .................................................................................. 6

3.0 Emission Results ....................................................................................................................... 8
  3.1 Field Strength Calculation....................................................................................................... 9
  3.2 Radiated Emission Configuration Photograph.......................................................................... 11
  3.3 Radiated Emission Data........................................................................................................ 12

4.0 Equipment Photographs ............................................................................................................ 15

5.0 Product Labelling .................................................................................................................... 17

6.0 Technical Specifications ........................................................................................................... 19

7.0 Instruction Manual .................................................................................................................. 21

8.0 Miscellaneous Information........................................................................................................ 23
  8.1 Measured Bandwidth ........................................................................................................... 24
  8.2 Discussion of Pulse Desensitization....................................................................................... 25
  8.3 Calculation of Average Factor............................................................................................... 26
  8.4 Emissions Test Procedures .................................................................................................. 27




FCC ID: DI2RCMHL
                                                                                                                                             iii


                          INTERTEK TESTING SERVICES



                                   List of attached file

         Exhibit type                File Description                 filename
Test Report             Test Report                        report.pdf
Operation Description   Technical Description              descri.pdf
Test Setup Photo        Radiated Emission                  radiated photos.doc
Test Report             Bandwidth Plot                     bw.pdf
External Photo          External Photo                     external photos.doc
Internal Photo          Internal Photo                     internal photos.doc
Block Diagram           Block Diagram                      block.pdf
Schematics              Circuit Diagram                    circuit.pdf
ID Label/Location       Label Artwork and Location         label.pdf
User Manual             User Manual                        manual.pdf
Timing Diagram          Timing Diagram                     timing.pdf




FCC ID: DI2RCMHL
                                                                                 iv


                   INTERTEK TESTING SERVICES



                           EXHIBIT 1

                     GENERAL DESCRIPTION




FCC ID: DI2RCMHL
                                               1


                                 INTERTEK TESTING SERVICES

1.0   General Description

1.1   Product Description

      The Equipment Under Test (EUT) is a Transmitter operating at 350MHz. The EUT is powered
      by 4.5V d.c. (3 x 1.5V “AAA” battery). It is designed to control a fireplace which equipped with
      a motorized Hi/Lo flame valve with the Hi/Lo flame type receiver connected. The transmitter has
      two large buttons for controlling the high/low flame of the valve. The transmitter is equipped
      with a manual switch which will cease the transmission within 1 s after releasing the button.
      Also, when it measure room temperature exceeding 99 degree Fahrenheit or when low battery is
      detected, it will transmit “off” signal to receiver and the duration of transmission is about 2.5 s.
      Besides, the transmitter will send out acknowledge signal to the receiver and the transmission
      duration is less than 1 s and the silent period is 15 min.

      Antenna Type : Integral, Internal

      For electronic filing, the brief circuit description is saved with filename: descri.pdf


1.2   Related Submittal(s) Grants

      This is a single application for certification of a transmitter.




FCC ID: DI2RCMHL
                                                                                                        2


                              INTERTEK TESTING SERVICES

1.3   Test Methodology

      Radiated emission measurements were performed according to the procedures in ANSI C63.4
      (1992). All measurements were performed in Open Area Test Sites. Preliminary scans were
      performed in the Open Area Test Sites only to determine worst case modes. For each scan, the
      procedure for maximizing emissions in Appendices D and E were followed. All Radiated tests
      were performed at an antenna to EUT distance of 3 meters, unless stated otherwise in the
      “Justification Section” of this Application.


1.4   Test Facility

      The open area test site and conducted measurement facility used to collect the emission data is
      located at Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong. This test facility and
      site measurement data have been fully placed on file with the FCC.




FCC ID: DI2RCMHL
                                                                                                   3


                   INTERTEK TESTING SERVICES



                           EXHIBIT 2

                   SYSTEM TEST CONFIGURATION




FCC ID: DI2RCMHL
                                               4


                                INTERTEK TESTING SERVICES

2.0   System Test Configuration

2.1   Justification

      The system was configured for testing in a typical fashion (as a customer would normally use it),
      and in the confines as outlined in ANSI C63.4 (1992).

      The EUT was powered from 3 x fully charged 1.5V "AAA" battery.

      For maximizing emissions, the EUT was rotated through 360°, the antenna height was varied
               from 1 meter to 4 meters above the ground plane, and the antenna polarization was
      changed. This step by step procedure for maximizing emissions led to the data reported in
      Exhibit 3.0.

      The unit was operated standalone and placed in the center of the turntable.

      The equipment under test (EUT) was configured for testing in a typical fashion (as a customer
      would normally use it). The EUT was placed on turntable, which enabled the engineer to
      maximize emissions through its placement in the three orthogonal axes.
      The worst case bit sequence was applied during test.

      For simplicity of testing, the unit was wired to transmit continuously.

      The frequency range from 350MHz to 3.5GHz was searched for spurious emissions from the
      device. Only those emissions reported were detected. All other emissions were at least 20 dB
      below the applicable limits.


2.2   EUT Exercising Software

      There was no special software to exercise the device. Once the button is depressed, the unit
      transmits the typical signal. For simplicity of testing, the unit was wired to transmit
      continuously.


2.3   Special Accessories

      There are no special accessories necessary for compliance of this product.




FCC ID: DI2RCMHL
                                                                                                     5


                                 INTERTEK TESTING SERVICES

2.4   Equipment Modification

      Any modifications installed previous to testing by Computime Limited will be incorporated in each
      production model sold/leased in the United States.

      No modifications were installed by Intertek Testing Services.


2.5   Measurement Uncertainty

      When determining of the test conclusion, the Measurement Uncertainty of test has been
      considered.


2.6   Support Equipment List and Description

      This product was tested in a standalone configuration.

      All the items listed under section 2.0 of this report are

      Confirmed by:

                       Wilson Loke
                       Manager
                       Intertek Testing Services Hong Kong Ltd.
                       Agent for Computime Limited




                                                                  Signature

                                     July 8, 2002                 Date




FCC ID: DI2RCMHL
                                                                                                     6


                   INTERTEK TESTING SERVICES



                           EXHIBIT 3

                       EMISSION RESULTS




FCC ID: DI2RCMHL
                                               7


                             INTERTEK TESTING SERVICES

3.0   Emission Results

      Data is included worst case configuration (the configuration which resulted in the highest
      emission levels). A sample calculation, configuration photographs and data tables of the
      emissions are included.




FCC ID: DI2RCMHL
                                                                                              8


                               INTERTEK TESTING SERVICES

3.1   Field Strength Calculation

      The field strength is calculated by adding the reading on the Spectrum Analyzer to the factors
      associated with preamplifiers (if any), antennas, cables, pulse desensitization and average factors
      (when specified limit is in average and measurements are made with peak detectors). A sample
      calculation is included below.

      FS = RA + AF + CF - AG + PD + AV

      where FS = Field Strength in dBµV/m
                    RA = Receiver Amplitude (including preamplifier) in dBµV
                    CF = Cable Attenuation Factor in dB
                    AF = Antenna Factor in dB
                    AG = Amplifier Gain in dB
                    PD = Pulse Desensitization in dB
                    AV = Average Factor in -dB



      In the radiated emission table which follows, the reading shown on the data table may reflect the
      preamplifier gain. An example of the calculations, where the reading does not reflect the
      preamplifier gain, follows:


      FS = RA + AF + CF - AG + PD + AV




FCC ID: DI2RCMHL
                                                                                                       9


                               INTERTEK TESTING SERVICES

3.1   Field Strength Calculation (cont’d)

      Example
      Assume a receiver reading of 62.0 dBµV is obtained. The antenna factor of 7.4 dB and cable
      factor of 1.6 dB is added. The amplifier gain of 29 dB is subtracted. The pulse desensitization
      factor of the spectrum analyzer was 0 dB, and the resultant average factor was -10 dB. The net
      field strength for comparison to the appropriate emission limit is 32 dBµV/m. This value in
      dBµV/m was converted to its corresponding level in µV/m.

      RA = 62.0 dBµV
      AF = 7.4 dB
      CF = 1.6 dB
      AG = 29.0 dB
      PD = 0 dB

      AV = -10 dB

      FS = 62 + 7.4 + 1.6 - 29 + 0 + (-10) = 32 dBµV/m

      Level in mV/m = Common Antilogarithm [(32 dBµV/m)/20] = 39.8 µV/m




FCC ID: DI2RCMHL
                                                                                                  10


                              INTERTEK TESTING SERVICES

3.2   Radiated Emission Configuration Photograph

                                    Worst Case Radiated Emission
                                               at
                                           350.066 MHz


      For electronic filing, the worst case radiated emission configuration photograph is saved with
      filename: radiated photos.doc




FCC ID: DI2RCMHL
                                                                                                 11


                               INTERTEK TESTING SERVICES

3.3   Radiated Emission Data

      The data on the following page lists the significant emission frequencies, the limit and the margin
      of compliance. Numbers with a minus sign are below the limit.


                                     Judgement: Passed by 12.7 dB


      TEST PERSONNEL:




      Signature



      Ben W. K. Ho, Compliance Engineer
      Typed/Printed Name


      July 8, 2002
      Date




FCC ID: DI2RCMHL
                                                                                                      12


                                   INTERTEK TESTING SERVICES

  Company: Computime Limited                                            Date of Test: June 6, 2002
  Model: Ambient RCMHL

                                                      Table 1

                                                Radiated Emissions

Polarity Frequency Reading Antenna                 Pre-      Average    Net          Limit       Margin
           (MHz)   (dB µ V ) Factor                Amp       Factor    at 3m         at 3m        (dB)
                              (dB)                 Gain       (-dB)  (dB µ V / m ) (dB µ V / m )
                                                   (dB)
  V         350.066        65.9         14.9        16          8.0         56.8         69.5        -12.7
  V         700.132        29.3         21.3        16          8.0         26.6         49.5        -22.9
  V        *1050.520       48.3         24.2        34          8.0         30.5         49.5        -19.0
  V        *1400.486       47.9         24.2        34          8.0         30.1         49.5        -19.4



  Notes:    1. Peak Detector Data unless otherwise stated.

            2. All measurements were made at 3 meter. Harmonic emissions not detected at the 3-meter
               distance were measured at 0.3-meter and an inverse proportional extrapolation was
               performed to compare the signal level to the 3-meter limit. No other harmonic emissions
               than those reported were detected at a test distance of 0.3-meter.

            3. Negative value in the margin column shows emission below limit.

            4. Horn antenna is used for the emission over 1000MHz.

            * Emission within the restricted band meets the requirement of Section 15.209.




  Test Engineer: Ben W. K. Ho




  FCC ID: DI2RCMHL
                                                                                                      13


                   INTERTEK TESTING SERVICES



                           EXHIBIT 4

                   EQUIPMENT PHOTOGRAPHS




FCC ID: DI2RCMHL
                                               14


                              INTERTEK TESTING SERVICES

4.0   Equipment Photographs

      For electronic filing, the photographs of the tested EUT are saved with filename: external
      photos.doc & internal photos.doc




FCC ID: DI2RCMHL
                                                                                             15


                   INTERTEK TESTING SERVICES



                           EXHIBIT 5

                      PRODUCT LABELLING




FCC ID: DI2RCMHL
                                               16


                              INTERTEK TESTING SERVICES

5.0   Product Labelling

      For electronic filing, the FCC ID label artwork and the label location are saved with filename:
      label.pdf




FCC ID: DI2RCMHL
                                                                                                  17


                   INTERTEK TESTING SERVICES



                           EXHIBIT 6

                   TECHNICAL SPECIFICATIONS




FCC ID: DI2RCMHL
                                               18


                                 INTERTEK TESTING SERVICES

6.0   Technical Specifications

      For electronic filing, the block diagram and schematics of the tested EUT are saved with
      filename: block.pdf and circuit.pdf respectively.




FCC ID: DI2RCMHL
                                                                                           19


                   INTERTEK TESTING SERVICES



                           EXHIBIT 7

                     INSTRUCTION MANUAL




FCC ID: DI2RCMHL
                                               20


                                INTERTEK TESTING SERVICES

7.0   Instruction Manual

      For electronic filing, a preliminary copy of the Instruction Manual is saved with filename:
      manual.pdf

      This manual will be provided to the end-user with each unit sold/leased in the United States.




FCC ID: DI2RCMHL
                                                                                                      21


                    INTERTEK TESTING SERVICES



                            EXHIBIT 8

                   MISCELLANEOUS INFORMATION




FCC ID: DI2RCMHL
                                                22


                              INTERTEK TESTING SERVICES

8.0   Miscellaneous Information

      This miscellaneous information includes details of the measured bandwidth, the test procedure
      and calculation of factors such as pulse desensitization and averaging factor.




FCC ID: DI2RCMHL
                                                                                                23


                               INTERTEK TESTING SERVICES

8.1   Measured Bandwidth

      For electronic filing, the plot shows the fundamental emission when modulated is saved with
      filename: bw.pdf. From the plot, the bandwidth is observed to be 80 kHz, at 20 dBc where the
      bandwidth limit is 875 kHz.

      Therefore, the unit meets the requirement of section 15.231(c).


                                      Figure 8.1      Bandwidth




FCC ID: DI2RCMHL
                                                                                               24


                                INTERTEK TESTING SERVICES

8.2   Discussion of Pulse Desensitization

      The determination of pulse desensitivity was made in accordance with Hewlett Packard
      Application Note 150-2, Spectrum Analysis ... Pulsed RF.

      Pulse desensitivity was not applicable for this device. The effective period (T eff) was
      approximately 0.34 ms for a digital "1" bit, as shown in the plots of Exhibit 8.3. With a resolution
      bandwidth (3 dB) of 100 kHz, the pulse desensitivity factor was 0 dB.




FCC ID: DI2RCMHL
                                                                                                       25


                                INTERTEK TESTING SERVICES

8.3   Calculation of Average Factor

      Averaging factor in dB = 20 log (duty cycle)

      The specification for output field strengths in accordance with the FCC rules specify
      measurements with an average detector. During testing, a spectrum analyzer incorporating a
      peak detector was used. Therefore, a reduction factor can be applied to the resultant peak signal
      level and compared to the limit for measurement instrumentation incorporating an average
      detector.

      The time period over which the duty cycle is measured is 100 milliseconds, or the repetition
      cycle, whichever is a shorter time frame. The worst case (highest percentage on) duty cycle is
      used for the calculation. The duty cycle is measured by placing the spectrum analyzer in zero
      scan (receiver mode) and linear mode at maximum bandwidth (3 MHz at 3 dB down) and viewing
      the resulting time domain signal output from the analyzer on a Tektronix oscilloscope. The
      oscilloscope is used because of its superior time base and triggering facilities.


      The duty cycle is simply the on-time divided by the period:

      The duration of one cycle         = 35 ms
      Effective period of the cycle     = (16 x 0.34 + 8 x 1.05) ms = 13.84 ms

      DC = 13.84 ms / 35 ms = 0.395

      Therefore, the averaging factor is found by 20 log10 0.395 = -8 dB

      For electronic filing, the plot shows the transmission timing is saved with filename: timing.pdf.




FCC ID: DI2RCMHL
                                                                                                          26


                               INTERTEK TESTING SERVICES

8.4   Emissions Test Procedures

      The following is a description of the test procedure used by Intertek Testing Services in the
      measurements of transmitters operating under Part 15, Subpart C rules.

      The test set-up and procedures described below are designed to meet the requirements of ANSI
      C63.4 - 1992.

      The transmitting equipment under test (EUT) is placed on a wooden turntable which is four feet
      in diameter and approximately one meter in height above the ground plane. During the radiated
      emissions test, the turntable is rotated and any cables leaving the EUT are manipulated to find the
      configuration resulting in maximum emissions. The EUT is adjusted through all three orthogonal
      axes to obtain maximum emission levels. The antenna height and polarization are varied during
      the testing to search for maximum signal levels. The height of the antenna is varied from one to
      four meters.

      Detector function for radiated emissions is in peak mode. Average readings, when required, are
      taken by measuring the duty cycle of the equipment under test and subtracting the corresponding
      amount in dB from the measured peak readings. A detailed description for the calculation of the
      average factor can be found in Exhibit 8.3.

      The frequency range scanned is from the lowest radio frequency signal generated in the device
      which is greater than 9 kHz to the tenth harmonic of the highest fundamental frequency or 40
      GHz, whichever is lower. For line conducted emissions, the range scanned is 450 kHz to 30
      MHz.




FCC ID: DI2RCMHL
                                                                                                      27


                               INTERTEK TESTING SERVICES

8.4   Emissions Test Procedures (cont'd)


      The EUT is warmed up for 15 minutes prior to the test.

      AC power to the unit is varied from 85% to 115% nominal and variation in the fundamental
      emission field strength is recorded. If battery powered, a new, fully charged battery is used.

      Conducted measurements are made as described in ANSI C63.4 - 1992.

      The IF bandwidth used for measurement of radiated signal strength was 100 kHz or greater when
      frequency is below 1000 MHz. Where pulsed transmissions of short enough pulse duration
      warrant, a greater bandwidth is selected according to the recommendations of Hewlett Packard
      Application Note 150-2. A discussion of whether pulse desensitivity is applicable to this unit is
      included in this report (See Exhibit 8.2). Above 1000 MHz, a resolution bandwidth of 1 MHz is
      used.

      Transmitter measurements are normally conducted at a measurement distance of three meters.
      However, to assure low enough noise floor in the forbidden bands and above 1 GHz, signals are
      acquired at a distance of one meter or less. All measurements are extrapolated to three meters
      using inverse scaling, unless otherwise reported. Measurements taken at a closer distance are so
      marked.