Test report

FCC ID: DGFTSSD5400

Test Report

Download: PDF
FCCID_2601735

                                              EMC TEST REPORT




                                                   NVLAP Lab Code 200033-0




                                                       Standard(s):

                                               47 CFR FCC Part 15.225
                                             FCC Parts 15.107 and 15.109
                                                RSS 210, Issue 8, 2010
                                               ICES 003, Issue 5, 2012

                                                 FCC ID: DGFTSSD5400
                                                  IC: 458F-TSSD5400

                                      Product: 3MTM Double-Sided ID1 Reader
                                                 Model: CR5400
                                                3M Division: TSSD




                                            Report Number: RE1501030-3
                                           Report Issue Date: April 8, 2015



                                                   Report Prepared By:


                                              Signature:

                                                      Yuriy Litvinov
                                                    Lead EMC Engineer

                                                     Tested By:
                                                 3M EMC Laboratory
                                      410 E. Fillmore Avenue, Building 76-01-1
                                          St. Paul, Minnesota 55107-1000




This report is the confidential property for the exclusive internal use of 3M Company and applies only to the specific item tested
under the stated test conditions. This test report shall not be reproduced except in full, without written approval of the 3M EMC
laboratory. Any changes impacting the attributes, functionality or operational characteristics documented in this report shall be
                     communicated to the body responsible for approving (certifying) the subject equipment.


 3                     3M EMC Laboratory
                                                 Report Number: RE1501030-3
                                                      Date: April 8, 2015
                                                                              Page 2 of 22



                                      TABLE OF CONTENTS
      Item                                     Description                         Page

1.0                Test Summary                                                      3
             1.1       Measurement Uncertainty                                       3
2.0                Equipment Description                                             4
             2.1      Equipment Under Test                                           4
3.0                EUT Configuration                                                 5
             3.1      Support Equipment                                              5
             3.2       Input/output Ports                                            5
             3.3       Operating Condition of EUT                                    5
             3.4       Exercising of EUT                                             5
4.0                Test Conditions and Results                                       6
             4.1        Conducted Emissions                                          6
             4.2        Radiated Emissions outside of the specified band            10
             4.3        20dB Bandwidth                                              13
             4.4        Field Strength of Fundamental                               15
             4.5        Frequency Stability                                         18


5.0                Test Equipment                                                   21
6.0                Revision History                                                 21
                   Certificate of Conformity                                        22


       3                 3M EMC Laboratory
                                                     Report Number: RE1501030-3
                                                          Date: April 8, 2015
                                                                                               Page 3 of 22


1.0      Test Summary

Based on the results of our investigation, we have concluded the product tested complies with the
requirements of the standard(s) indicated. The results obtained in this test report pertain only to the item(s)
tested.


 No            Standard                         Test Requirements                    Result       Comments


 4.1   15.107/15.207/RSS-Gen                   Conducted Emissions                    pass

           15.225(d)/15.209             Radiated Emissions outside of the
 4.2                                                                                  pass
               RSS210                            specified band

 4.3       2.1049/RSS Gen                         20dB Bandwidth                      pass

 4.4    15.225(a)(b)(c)/RSS210            Field Strength of Fundamental               pass

 4.5       15.225(e)/RSS210                     Frequency Stability                   pass




              Note:




1.1     Measurement Uncertainty

The measured value related to the corresponding limit will be used to decide whether the equipment meets the
requirements. The measurement uncertainty figures were calculated and correspond to a coverage factor of k=2,
providing a confidence level of respectively 95.45 % in the case where the distributions characterizing the actual
measurement uncertainties are normal (Gaussian).

 Radiated emissions                        5.20 dB
 Conducted emissions                       3.60 dB
 Harmonics and Flicker                     3.32 dB


      3               3M EMC Laboratory
                                                     Report Number: RE1501030-3
                                                          Date: April 8, 2015
                                                                                               Page 4 of 22


2.0     Equipment Description

  2.1    Equipment Under Test
                                   The 3M CR5400 Double-sided ID1 Reader inspects and images
                   Description:    government issued identity documents ID1 sized (85 x 54mm) in a
                                   variety of market segments like Retail, Financial and Hospitality.
                      Model(s):    CR5400

                 Serial number:    N/A


                 Client Contact:   Stephen P. Bernard

                        Phone:     613 722 2070 ext 1755

                   3M Division:    TSSD

                 Modifications:    n/a

        Frequency Range (MHz) :    13.56MHz

               Modulation Type:    ASK

                   Channel No.:    1

        Maximum Output Power:      N/A

                       Antenna:    Internal Loop Antenna

           Equipment Category:           General             Portable            Indoor Use
                                   Voltage:           120VAC            230VAC                VDC
                  Rated Power:     Frequency:         50Hz              60Hz
                                   Current:           1.0Amps

                    Test Dates:    02/25-03/12/2015

                Received Date:     01/10/2015
                                         Poor          Good
           Received Conditions:
                                         Prototype     Production


       3                  3M EMC Laboratory
                                                       Report Number: RE1501030-3
                                                            Date: April 8, 2015
                                                                                                Page 5 of 22


3.0     EUT Configuration

3.1     Support Equipment

 No.        Product Type                Manufacturer                     Model                  Comments

  1         Power Supply                    DVE                    DSA-12CA-05

  2        EMC Lab Laptop                   HP                   Elite Book 8540W


3.2     Cables


 No.              Name                     Type                 Length       Shielding          Comments

              USB Cable                                          1m              Yes      Mini-B USB-USB 2.0 with
  1                                                                                      molded ferrites on each end




3.3     Operating Condition of EUT

                                                   Operation Modes

       Stand by

       Continuous Monitored Operation

       Continuous Unmonitored Operation

       Passport Reader was connected to the PC over USB cable to read the plastic card image using AutoCal
       SW00355 2.04 software


3.4     Exercising of EUT

 No.                                         Description of EUT Exercising

  1    Continues transmission of modulated signal at 13.56MHz

  2


      3                     3M EMC Laboratory
                                                       Report Number: RE1501030-3
                                                            Date: April 8, 2015
                                                                                                 Page 6 of 22


4.0       Test Conditions and Results
  4.1       Conducted Emissions Data
        The AMN was placed 0.8 m from the boundary of the unit under test and bonded to a ground reference
Method: plane. This distance was between the closest points of the AMN and the EUT. All other units of the EUT and
        associated equipment were at least 0.8 m from the AMN. All power was connected to the system through
        Artificial Mains Network (AMN). Conducted voltage measurements on mains lines were made at the output
        of the AMN.
                                             Laboratory Ambient Temperature                     21°C
            Test Verification:
                                             Relative Humidity                                  35%
                                                ANSI C63.4:2009
                                                ANSI C63.10:2009
            Reference Standard:                                                     Measurement Point
                                                FCC Part 15.207/RSS Gen
                                                                                      Mains
                                                FCC Part 15.247/RSS 210
                                                                                      Telecommunication ports

                                                150KHz to 30KHz
             Frequency Range:


              Nominal Voltage:                  120VAC      230VAC

                   Tested By:                                           Date: 02/26/2015
                                             Mike Schultz
                                                       Limits
                                                                 Limit dB (µV)
Frequency (MHz)             Quasi-Peak               Average               Result             Comments
      0.15 to 0.50               66 to 56            56 to 46               pass
       0.50 to 5                   56                  46                   pass
        5 to 30                    60                  50                   pass


  Modifications:
         Note:           The RF exclusion 13.56MHz band applied to RFID


  3                     3M EMC Laboratory
                                             Report Number: RE1501030-3
                                                  Date: April 8, 2015
                                                                                      Page 7 of 22



Frequency           QP Line 1   AVG Line 1   QP Limit     AVG Limit      QP Margin       AVG Margin
  (MHz)              dB (µV)     dB (µV)     dB (µV)       dB (µV)          dB              dB

  0.168               37.3        28.39       65.04         55.04            -27.74        -26.65

  3.976               34.66       26.17        56            46              -21.34        -19.83

  5.073               34.94       26.36        60            50              -25.06        -23.64

  5.67                38.45       29.74        60            50              -21.55        -20.26

  5.946               37.87       30.75        60            50              -22.13        -19.25

  6.004               36.8        29.25        60            50              -23.2         -20.75

  6.27                38.2        28.79        60            50              -21.8         -21.21



Frequency           QP Line 2   AVG Line 2   QP Limit     AVG Limit      QP Margin       AVG Margin
  (MHz)              dB (µV)     dB (µV)     dB (µV)       dB (µV)          dB              dB

  0.155               41.93       32.37       65.74         55.74            -23.81        -23.37

  0.206               33.46       25.75       63.36         53.36            -29.91        -27.61

  0.359               41.62        41         58.75         48.75            -17.13         -7.74

  4.38                37.26       29.74        56            46              -18.74        -16.26

  6.055               36.72       28.32        60            50              -23.28        -21.68

  6.693               35.28       27.19        60            50              -24.72        -22.81

  6.796               37.38       31.29        60            50              -22.62        -18.71

  0.155               41.93       32.37       65.74         55.74            -23.81        -23.37

          Voltage                                       120VAC      230VAC

            Notes


3                                                      3M EMC Laboratory
                                                                                                             Report Number: RE1501030-3
                                                                                                                  Date: April 8, 2015
                                                                                                                                                                       Page 8 of 22




                                                                                                                                          RE Proj ect # - RE1402035
                                                                                                            3M Company                    Model # - CR5400
                                                                                                                                          EUT Description - Passport Reader
                                                                                                        Conducted Emissions               Serial # -
                                                                                                                                          EUT Pow er - 120 VAC / 60 Hz
                                                                                                   CISPR22_FCC Part 15, Class B, Line 1


                 80.0

                 75.0

                 70.0

                 65.0

                 60.0

                 55.0
Amplitude dBuV




                 50.0

                 45.0

                 40.0

                 35.0

                 30.0

                 25.0

                 20.0

                 15.0

                 10.0

                  5.0

                   0
                  150.0K                                                                    1.0M                                          10.0M                                     30.0M
                                                                                                                Frequency
                                                                                                                                                                QP Class B Limit
                        Configuration:
                                                                                                                                                                AVG Class B Limit
                        Connected v ia USB to laptop computer, reading a card.                                                                                  Scan
                                                                                                                                                                Top Peaks
                        Tested w ith USB cable w ith molded ferrite on each of the cable.
                        Digital & RF cables taped and isolated from each other.




                                                                                                                                          RE Proj ect # - RE1402035
                                                                                                            3M Company                    Model # - CR5400
                                                                                                                                          EUT Description - Passport Reader
                                                                                                        Conducted Emissions               Serial # -
                                                                                                                                          EUT Pow er - 120 VAC / 60 Hz
                                                                                                   CISPR22_FCC Part 15, Class B, Line 2


                 80.0

                 75.0

                 70.0

                 65.0

                 60.0

                 55.0
Amplitude dBuV




                 50.0

                 45.0

                 40.0

                 35.0

                 30.0

                 25.0

                 20.0

                 15.0

                 10.0

                  5.0

                   0
                  150.0K                                                                    1.0M                                          10.0M                                     30.0M
                                                                                                               Frequency
                                                                                                                                                                QP Class B Limit
                        Configuration:
                                                                                                                                                                AVG Class B Limit
                        Connected v ia USB to laptop computer, reading a card.                                                                                  Scan
                                                                                                                                                                Top Peaks
                        Tested w ith USB cable w ith molded ferrite on each of the cable.
                        Digital & RF cables taped and isolated from each other.


3   3M EMC Laboratory
                        Report Number: RE1501030-3
                             Date: April 8, 2015
                                                     Page 9 of 22




                 Test Set Up Photo


   3                        3M EMC Laboratory
                                                      Report Number: RE1501030-3
                                                           Date: April 8, 2015
                                                                                                     Page 10 of 22




 4.2        Radiated Emissions Data
            Measurements were made in a 3-meter semi-anechoic chamber that complies to CISPR 16. The EUT
Method:     was rotated 360° about its azimuth with the receive antenna located at various heights in horizontal and
            vertical polarities. Final measurements (quasi-peak) were then performed by rotating the EUT 360° and
            adjusting the receive antenna height from 1 to 4 m. All frequencies were investigated in both horizontal
            and vertical antenna polarity, where applicable.
                                     Laboratory Ambient Temperature                               23°C
       Test Verification:
                                     Relative Humidity                                             35%
                                        ANSI C63.4:2009                                    Measurement Distance
                                        ANSI C63.10:2009
       Reference Standard:
                                        FCC Part 15.109/ICES 003
                                                                                             3 Meters
                                        FCC Part 15.247/RSS 210
                                        FCC Part 15.209
                                        30 MHz TO 10GHz
        Frequency Range:


        Nominal Voltage:                120VAC       230VAC

            Tested By:                                                            Date: 02/27/2015
                                     Mike Schultz
                                                       Limits
                                                                         Limit dB (µV/m)
         Frequency (MHz)                Quasi-Peak               Average            Distance             Results
           0.009-0.490                                          2400/F(KHz)           300                  pass
           0.490-1.705                 24000/F(KHz)                                    30                  pass
             1.705-30                       29.5                                       30                  pass
             30 to 88                        40                                        3                   pass

              88-216                        43.5                                       3                   pass

             216-960                         46                                        3                   pass
            Above 960                                               54                 3                   N/A


          Modifications:
              Note:                  For emission in the restricted bands, the limit of 15.209 was used.


 3                  3M EMC Laboratory
                                           Report Number: RE1501030-3
                                                Date: April 8, 2015
                                                                                Page 11 of 22




Frequency             QP Reading     Total CF     Net at 3 m     Limit (dBµV/m)        Margin
             Pol.
  (MHz)                dBµV/m          dB          dBµV/m                               dB
  16.59                  -10.3         37.3          26.7              69.5             -42.8

  27.12                  -10.1         32.6          22.5              69.5             -47.0

 128.005      V          5.11          15.67         20.78            43.52            -22.74

 192.745      H          18.42         13.29         31.71            43.52            -11.81

 222.111      H          21.85         13.29         35.14            46.02            -10.88

 250.022      H          25.48         16.43         41.91            46.02             -4.11

 311.901      H          26.45         17.68         44.13            46.02             -1.89

 391.505      H          19.18         19.77         38.94            46.02             -7.08

 475.529      V          12.33         21.6          33.93            46.02            -12.09

 509.703      H          15.92         22.21         38.13            46.02             -7.89

 959.915      H          13.23         26.06         39.28            46.02             -6.74

     Notes                       Total CF = Antenna Factor + Cable Factor - AMP Gain


3   3M EMC Laboratory
                        Report Number: RE1501030-3
                             Date: April 8, 2015
                                                     Page 12 of 22




                   Test Set Up Photo


3                                                      3M EMC Laboratory
                                                                                                              Report Number: RE1501030-3
                                                                                                                   Date: April 8, 2015
                                                                                                                                                                  Page 13 of 22




                                                                                                            3M Company                   RE Proj ect # - RE1402035
                                                                                                                                         Model # - CR5400
                                                                                                     Radiated Emissions Prescan          EUT Description - Passport Reader
                                                                                                                                         Serial # -
                                                                                                       FCC Part 15, Class B, Vertical    EUT Pow er - 230 VAC / 50 Hz


                 80.0

                 75.0

                 70.0

                 65.0

                 60.0

                 55.0
Amplitude dBuV




                 50.0

                 45.0

                 40.0

                 35.0

                 30.0

                 25.0

                 20.0

                 15.0

                 10.0

                  5.0

                    0
                   30.0M                                                                    100.0M                                                                                   1.0G
                                                                                                              Frequency MHz
                                                                                                                                                                             Limit
                        Configuration:
                                                                                                                                                                             Vert Scan
                        Connected v ia USB to laptop computer, reading a card.
                        Tested w ith USB cable w ith molded ferrite on each of the cable.
                        Digital & RF cables taped and isolated from each other.




                                                                                                                                         RE Proj ect # - RE1402035
                                                                                                            3M Company                   Model # - CR5400
                                                                                                                                         EUT Description - Passport Reader
                                                                                                     Radiated Emissions Prescan          Serial # -
                                                                                                                                         EUT Pow er - 230 VAC / 50 Hz
                                                                                                      FCC Part 15, Class B, Horizontal


                 80.0

                 75.0

                 70.0

                 65.0

                 60.0

                 55.0
Amplitude dBuV




                 50.0

                 45.0

                 40.0

                 35.0

                 30.0

                 25.0

                 20.0

                 15.0

                 10.0

                  5.0

                    0
                   30.0M                                                                    100.0M                                                                                   1.0G
                                                                                                              Frequency MHz
                                                                                                                                                                             Limit
                        Configuration:
                                                                                                                                                                             Horiz Scan
                        Connected v ia USB to laptop computer, reading a card.
                        Tested w ith USB cable w ith molded ferrite on each of the cable.
                        Digital & RF cables taped and isolated from each other.


  3                   3M EMC Laboratory
                                                  Report Number: RE1501030-3
                                                       Date: April 8, 2015
                                                                                          Page 14 of 22



4.3     20dB Bandwidth
                       The 20dB bandwidth was measured with a spectrum analyzer connected via Loop antenna
       Method:
                       placed near the EUT while the EUT is operating in transmissions mode
                       Laboratory Ambient Temperature                              23°C
                       Relative Humidity                                           35%

                          ANSI C63.10:2013                     Measurement Point
Reference Standard:       FCC Part 15.109/ICES 003               Conducted
                          FCC Part 15.247/RSS 210                Radiated
                          FCC Part 15.209
                                                               RBW ≥ 1% of the 20 dB bandwidth
 Frequency Range:         13.553 MHz -13.567MHz
                                                               VBW ≥ RBW

 Nominal Voltage:         120VAC       VDC

      Tested By:                                               Date: 03/12/2015
                       Mike Schultz


        Note:


            Frequency (MHz)                20 dB Bandwidth      99% Bandwidth
                                                                                          Results
               (PR-ASK)                          (KHz)              (KHz)
           13.553 MHZ -13.567                   2.548                 2.170                pass


3   3M EMC Laboratory
                        Report Number: RE1501030-3
                             Date: April 8, 2015
                                                     Page 15 of 22


    3                       3M EMC Laboratory
                                                        Report Number: RE1501030-3
                                                             Date: April 8, 2015
                                                                                                 Page 16 of 22



   4.4       Field Strength of Fundamental

             Measurements was performed with modulated carrier at the highest power level at which the transmitter is
Method: intended to operate. The analyzer offset was adjusted to compensate for the attenuator and other losses.

                              Laboratory Ambient Temperature                                       21°C
                              Relative Humidity                                                     45%
                                  ANSI C63.10:2013
                                  FCC Part 15.255/RSS210
  Reference Standard:                                                                  Measurement Point
                                  FCC Part 15.109/ICES 003
                                  FCC Part 15.209                                        Conducted
                                                                                         Radiated at 3 meters
    Frequency Range:              13.553 MHz -13.567MHz

                                                             Field Strength uV/m at      Field Strength dBuV/m at
                                    Frequency (MHz)
                                                                       30m                          3m

                                      1.705-13.110                     30                           69.5

                                     13.110-13.410                     106                          80.5

                                     13.410-13.553                     334                          90.5

           Limit                     13.553-13.567                    15848                        124.0

                                     13.567-13.710                     334                          90.5

                                     13.710-14.010                     106                          80.5

                                       14.010-30.0                     30                           69.5

    Nominal Voltage:              230VAC       120VAC

         Tested By:           Yuriy Litvinov                                            Date: 03/12/2015


           Note:



  Frequency            Pol         QP Reading           Limit (3m)           Margin            Antenna
    (MHz)             (XYZ)         dBµV/m              (dBµV/m)              dB              Height (m)

     13.56              Y              62.5                124                -61.5              1.0


3   3M EMC Laboratory
                        Report Number: RE1501030-3
                             Date: April 8, 2015
                                                     Page 17 of 22


3                    3M EMC Laboratory
                                                    Report Number: RE1501030-3
                                                         Date: April 8, 2015
                                                                                                 Page 18 of 22



 4.5       Frequency Stability
           Measurements was performed with modulated carrier at the highest power level at which the
Method:    transmitter is intended to operate. The frequency was measured under normal and extreme test
           conditions test conditions. The analyzer offset was adjusted to compensate for the attenuator and other
           losses. During extreme test conditions, both extreme temperature and voltage apply simultaneously.
                            Laboratory Ambient Temperature                                    21°C
                            Relative Humidity                                                 35%
                                                                                Measurement Point
                                Part 15.225
 Reference Standard:                                                              Conducted
                                ANSI C63.10:2013
                                                                                  Radiated
  Frequency Range:              13.553 MHz -13.567MHz                                 Maximum Deviation

          Limit:                + 100ppm                                                     7.5 ppm

   Nominal Voltage:             230VAC        120VAC

                                General                 - 20.0 to +50.0
 Extreme Temperature
                                Portable
      Ranges (C0)
                                Indoor Use

    Extreme Test                Mains Voltage           + 15%
       Voltages:                Battery                 0.85     1.15

       Tested By:                                                                Date:03/13/2015
                            Mike Schultz


3           3M EMC Laboratory
                                   Report Number: RE1501030-3
                                        Date: April 8, 2015
                                                                 Page 19 of 22



Channels                                 Measured    Frequency
            Temperature     Voltage
Frequency                                Frequency   Deviation
                C0        (VAC/50Hz)                               Result
  (MHz)                                    (MHz)       (MHz)
                             102           13.5603       0          pass

                55           120           13.5603       0          pass

                             138           13.5603       0          pass

                             102           13.5603       0          pass

                30           120           13.5603       0          pass

                             138           13.5603       0          pass

                             102           13.5603       0          pass

                20           120           13.5603       0          pass

                             138           13.5603       0          pass

                             102           13.5603       0          pass
13.56MHz        10           120           13.5603       0          pass

                             138           13.5603       0          pass

                             102           13.5603       0          pass

                 0           120           13.5603       0          pass

                             138           13.5603       0          pass

                             102           13.5604     0.0001       pass

                -10          120           13.5604     0.0001       pass

                             138           13.5604     0.0001       pass

                             102           13.5604     0.0001       pass

                -20          120           13.5604     0.0001       pass

                             138           13.5604     0.0001       pass


3   3M EMC Laboratory
                        Report Number: RE1501030-3
                             Date: April 8, 2015
                                                     Page 20 of 22




                   Test Set Up Photo


 3                       3M EMC Laboratory
                                                      Report Number: RE1501030-3
                                                           Date: April 8, 2015
                                                                                            Page 21 of 22




 5.0          Test Equipment

                                                Test Equipment Used

        Description              Manufacturer              Model         Identifier       Cal. Due     Check
   Biconilog Antenna                  Schaffner          CBL6112B         27491           10/2015
       Horn Antenna               AH Systems              SAS 571          1010           10/2015
       Loop Antenna                    EMCO               ALR25M           1011           10/2015
        EMI Receiver           Rohde & Schwarz            ESIB 40         100235          10/2015
        EMI Receiver                   Agilent            E4448A         1530975          10/2015
       Signal Analyzer                 Agilent            N9000A        MY53031040        10/2015
            LISN                      TESEQ               NNB51            1130           10/2015
Harmonic/Flicker Source         Cal. Instruments         C4-5001iX        57162           10/2015
          Amplifier                      AR             250W1000AM        14354           10/2015
          Amplifier                      AR              25S1G4A           4003           10/2015
   Signal Generator                      HP                8656A        2326A05125        10/2015
   Signal Generator                    Agilent            E8257D          160895          10/2015
        Field Probe                      AR               FL7006          25019           10/2015
        Field Monitor                    AR               FM2000          14292           10/2015
          AC CDN                      Schaffner            M316,          21937           10/2015
          AC CDN                       Teseq               M016,          26131           10/2015
 Current Injection Coil          A.H. Systems           ICP-200/521         149           10/2015
RF Conducted System                   TESEQ             NSG 4070-75        1141           10/2015
       ESD Generator                  KeyTek             MZ-15/EC         609325          10/2015
 EFT/Surge Generator             ThermoFisher           EMC Pro Plus       1146           10/2015
         EMF Meter                    NARDA               ELT400           1139           10/2015
 EMF Test Generator                     FCC             F-1000-4-8-G       9940           10/2015
   AC Power System                      Titan             MAC-03         6619921          10/2015
       EMC Software              ETS-Lindgren              TILE 6                         10/2015



 6.0        Report revision history
  Revision Level                      Date              Report Number                    Notes
              0                  04/08/2015              RE1501030-3                  Original Issue


  3                   3M EMC Laboratory
                                                  Report Number: RE1501030-3
                                                       Date: April 8, 2015
                                                                                           Page 22 of 22




            Certificate of Conformity
                     3M EMC Laboratory
                        SEMS Global Regulatory Engineering
                                 Building 76‐01‐01
                           St. Paul, MN 55144‐1000, USA

              MANUFACTURER’S NAME                                  3M COMPANY
              NAME OF EQUIPMENT                                    3MTM Double‐Sided ID1 Reader
              MODEL NUMBER(S)                                      CR5400
              TEST REPORT NUMBER                                   RE1501030‐3
              DATE OF ISSUE                                        April 8, 2015


   Referring to the performance criteria and operating mode during the tests specified in this report the
                   equipment complies with the essential requirements herein specified:



     47 CFR Part 15 – Subpart C – Intentional                 FCC Part 15.225
     Radiator

     License‐exempt Radio Apparatus (All                      RSS 210, Issue 8, 2010
     Frequency Bands): Category I Equipment


                                                              47 CFR:2014, FCC Parts 15.107 and 15.109
                                                              ICES‐003, Issue 5, 2012

Comments:




                                                                               NVLAP Lab Code 200033-0



      ____________
      Yuriy Litvinov
      Lead EMC Engineer



Document Created: 2015-04-08 12:35:49
Document Modified: 2015-04-08 12:35:49

© 2024 FCC.report