Test Report P74 V6

FCC ID: DD4BLX1H11

Test Report

Download: PDF
FCCID_4356731

                                                                    Engineering Test Report No. SEL-038A


                                             SHURE
                    ELECTROMAGNETIC COMPATIBILITY LABORATORY
                                  TEST REPORT


TEST REPORT TITLE: Electromagnetic Compatibility Tests for Shure BLX1 H11 and J11 Bodypack Transmitter


TEST ITEM DESCRIPTION: BLX1 is a digital wireless bodypack transmitter intended for use in mid-tier
presentation, installed, and performance markets. The system operates in the UHF TV bands. Regionally
dependent 2mW, 10mW and 35mW output power modes are available. The BLX1 transmitter is capable of
operating with AA alkaline batteries.

Shure Incorporated
5800 West Touhy Avenue
Niles, IL 60714



PROJECT ID NUMBER: SEL-038A

DATE TESTED: 10/11/2018 TO 01/28/2019

TEST PERSONNEL: Juan Castrejon, Hannah Hart, Alex Mishinger, Jamal Qureshi

TEST SPECIFICATION (STANDARDS APPLIED): FCC Part 74: Experimental Radio, Auxiliary, Special Broadcast And
Other Program Distributional Services
RSS 210 Issue 9, Annex G: Low-Power Radio Apparatus Operating in the Television Bands




 TEST REPORT
 BY:                                               Global Compliance Engineer            1/29/2019
                              SIGNATURE                         POSITION                       DATE

 APPROVED BY:                                      GC Project Engineer                   1/29/2019
                              SIGNATURE                         POSITION                       DATE




       SEL-F-11 Main Body Test Form           Page 0 of 33                        Form Revision: 2
                                                                                         6/9/2017


                                                                                                            Engineering Test Report No. SEL-038A



                                                                    Table of Contents

Table of Contents .............................................................................................................................................. 1
List of Appendices ............................................................................................................................................. 3
Report Revision History ..................................................................................................................................... 4
Report Summary ............................................................................................................................................... 5
   1.     Introduction ............................................................................................................................................. 5
                Scope of Tests ................................................................................................................................. 5
                Purpose ........................................................................................................................................... 5
                Deviations, Additions, and Exclusions .............................................................................................. 5
                EMC Laboratory Identification .......................................................................................................... 5
                Summary of Tests Performed .......................................................................................................... 5
   2.     Applicable Documents ............................................................................................................................ 6
   3.     EUT Set-Up and Operation ..................................................................................................................... 6
                General Description ......................................................................................................................... 6
                Test Samples ................................................................................................................................... 6
                Test Setup ....................................................................................................................................... 6
   4.     Test Instrumentation ............................................................................................................................... 6
   5.     Test Procedures...................................................................................................................................... 6
   6.     Other Test Conditions ............................................................................................................................. 6
                Test Personnel ................................................................................................................................. 6
                Disposition of the EUT ..................................................................................................................... 6
   7.     Results .................................................................................................................................................... 7
   8.     Conclusions ............................................................................................................................................ 7
   9.     Certification ............................................................................................................................................. 7
   10.       Equipment List..................................................................................................................................... 7
Appendix A:            Frequency Stability ................................................................................................................... 9
   A.1.      Purpose ............................................................................................................................................... 9
   A.2.      Requirements ...................................................................................................................................... 9
   A.3.      Measurement Uncertainty ................................................................................................................... 9
   A.4.      Test Setup and Instrumentation ........................................................................................................... 9
   A.5.      EUT Operation .................................................................................................................................... 9
   A.6.      Specific Test Procedures ................................................................................................................... 10
   A.7.      Results .............................................................................................................................................. 10
   A.8.      Conclusion ........................................................................................................................................ 12
Appendix B:            Necessary Bandwidth ............................................................................................................. 14

          SEL-F-11 Main Body Test Form                                    Page 1 of 33                                            Form Revision: 2
                                                                                                                                         6/9/2017


                                                                                                       Engineering Test Report No. SEL-038A

  B.1.    Purpose ............................................................................................................................................. 14
  B.2.    Requirements .................................................................................................................................... 14
  B.3.    Measurement Uncertainty ................................................................................................................. 15
  B.4.    Test Setup and Instrumentation ......................................................................................................... 15
  B.5.    EUT Operation .................................................................................................................................. 16
  B.6.    Specific Test Procedures ................................................................................................................... 16
  B.7.    Results .............................................................................................................................................. 17
  B.8.    Conclusion ........................................................................................................................................ 20
Appendix C:         Field Strength Spurious Emissions ......................................................................................... 21
  C.1.    Purpose ............................................................................................................................................. 21
  C.2.    Requirements .................................................................................................................................... 21
  C.3.    Measurement Uncertainty ................................................................................................................. 21
  C.4.    Test Setup and Instrumentation ......................................................................................................... 22
  C.5.    EUT Operation .................................................................................................................................. 25
  C.6.    Specific Test Procedures ................................................................................................................... 25
  C.7.    Results .............................................................................................................................................. 27
  C.8.    Conclusion ........................................................................................................................................ 29
Appendix D:         RF Output Power .................................................................................................................... 30
  D.1.    Purpose ............................................................................................................................................. 30
  D.2.    Requirements .................................................................................................................................... 30
  D.3.    Measurement Uncertainty ................................................................................................................. 30
  D.4.    Test Setup and Instrumentation ......................................................................................................... 30
  D.5.    EUT Operation .................................................................................................................................. 32
  D.6.    Specific Test Procedures ................................................................................................................... 32
  D.7.    Results .............................................................................................................................................. 32
  D.8.    Conclusion ........................................................................................................................................ 33

Note: This report shall not be reproduced, except in full, without the written approval of the Shure Incorporated
Electromagnetic Laboratory (SEL). Total Page Count, including appendices is 31.




         SEL-F-11 Main Body Test Form                                 Page 2 of 33                                            Form Revision: 2
                                                                                                                                     6/9/2017


                                                     Engineering Test Report No. SEL-038A

                               List of Appendices

 Appendix                              Test Description
    A                                 Frequency Stability
    B                                Necessary Bandwidth
    C                                 Radiated Emissions
    D                                  RF Output Power




SEL-F-11 Main Body Test Form     Page 3 of 33                     Form Revision: 2
                                                                         6/9/2017


                                                           Engineering Test Report No. SEL-038A

                               Report Revision History

Revision           Date                                  Description
    0           1/29/2019                              Released for use
                                  Revised to divide FCC part 74 and 15 data into separate
    1           4/19/2019        reports, to include EIRP values for RF Power Output data,
                                             and to make minor edits throughout.
    2           4/23/2019               Corrected a mathematical error in EIRP data.
                                    Reformatted cover page, added details about EIRP
                                      calculation, replaced radiated emissions graphs
    3           5/10/2019
                                 (uncalibrated) with substitution data, and made minor edits
                                                         throughout.
    4           6/11/2019                         Corrected substitution data
    5            7/8/2019                      Added additional substitution data




SEL-F-11 Main Body Test Form         Page 4 of 33                         Form Revision: 2
                                                                                 6/9/2017


                                                                   Engineering Test Report No. SEL-038A

                                          Report Summary


1.    Introduction
         Scope of Tests
         This document presents the results of a series of electromagnetic compatibility (EMC) tests
         performed on the BLX1 H11 and BLX1 J11. The test items were manufactured and submitted for
         testing by Shure Incorporated located in Niles, IL. The data was taken following the measurement
         methods as described in the test specifications listed on page 1 of this document. Provided is the
         data for the test samples which also includes a summary of the measurements made and a
         description of the measurement setup.
         Purpose
         This series of tests was performed to determine if the test item would meet the selected
         requirements of the following specifications:
         FCC Part 74.861
         RSS 210 Issue 9, Annex G
         Deviations, Additions, and Exclusions
         EMC Laboratory Identification
         The electromagnetic compatibility tests were performed at the Shure Electromagnetic Laboratory,
         Shure Incorporated, 5800 West Touhy Ave, Niles, Illinois 60714-4608. This laboratory is
         registered with ISED Canada as Site # 616A-1. The Shure Electromagnetic Laboratory is
         accredited by the National Institute of Standards and Technology (NIST) under the National
         Voluntary Laboratory Accreditation Program (NVLAP). The NVLAP Lab Code is: 200946-0.
         Summary of Tests Performed
         The following electromagnetic compatibility tests were performed on the test item in accordance
         with the specifications as stated in the following:
         FCC Part 2
         ETSI EN 300 422-1
         RSS 210 Issue 9, Annex G

                               Table 1-1: Summary of tests performed
         Test                                                    Described in
                         Description        Tested Range                             Test Results
     Specifications                                               Appendix
                                            572.150MHz –
      FCC 74.861
                           Frequency         595.850MHz
      RSS 210.9                                                        A                 PASS
                            Stability       596.125MHz –
       Annex G
                                             615.875MHz
                                            572.150MHz –
      FCC 74.861
                           Necessary         595.850MHz
      RSS 210.9                                                        B                 PASS
                           Bandwidth        596.125MHz –
       Annex G
                                             615.875MHz
      FCC 74.861        Field Strength
      RSS 210.9            Spurious        25MHz – 18GHz               C                 PASS
       Annex G            Emissions




     SEL-F-11 Main Body Test Form            Page 5 of 33                          Form Revision: 2
                                                                                          6/9/2017


                                                                    Engineering Test Report No. SEL-038A

                                             572.150MHz –
      FCC 74.861
                                              595.850MHz
      RSS 210.9         RF Output Power                                D                 PASS
                                             596.125MHz –
       Annex G
                                              615.875MHz
2.    Applicable Documents
      The following documents of the exact issue designated form part of this document to the extent
      specified herein:
      FCC Part 15
      RSS 210 Issue 9
3.    EUT Set-Up and Operation
         General Description
         The Shure BLX1 Bodypack Transmitter is a digital wireless bodypack transmitter intended for use
         in mid-tier presentation, installed, and performance markets. The system operates in the UHF TV
         bands and is frequency modulated. Regionally dependent 2mW, 10mW and 35mW output power
         modes are available. Wireless signals are modulated using frequency modulation. The BLX1
         transmitter is capable of operating with AA alkaline batteries.
         Test Samples
         The following BLX1 H11 and BLX1 J11 samples were tested:

                                   Table 3-1: Transmitter Samples
                        RF Power Output
Frequency Band                                         EUT Serial Number               Frequency Range
                             In mW
       H11                     10                          TS1R & TS1C                  572MHz-596MHz
       J11                     10                          TS1R & TS1C                  596MHz-616MHz
         Test Setup
         3.3.1. Power Input
                 The EUT obtained power through internal alkaline batteries.
         3.3.2. Signal Input /Output Leads
         3.3.3. Grounding Considerations
         3.3.4. Operational Mode
4.    Test Instrumentation
      A list of the test equipment used can be found in Table 10-1. All equipment is calibrated on an annual
      basis. All calibrations are traceable to the National Institute of Standards and Technology (NIST).
5.    Test Procedures
      The specific test procedures are presented in the individual appendices.
6.    Other Test Conditions
         Test Personnel
         All EMC tests were performed by qualified personnel from the Shure EMC Laboratory.
         Disposition of the EUT
         The EUTs and all associated equipment were returned to Shure Incorporated upon completion of
         the tests.


     SEL-F-11 Main Body Test Form             Page 6 of 33                         Form Revision: 2
                                                                                          6/9/2017


                                                                        Engineering Test Report No. SEL-038A

   7.    Results
         The results are presented in the individual test appendices. It was found that the EUT met the
         requirements of the following:
         FCC Part 74
         RSS 210, Issue 9
   8.    Conclusions
         It was determined that the BLX1 H11 and BLX1 J11 did fully comply with the requirements of the
         following:
         FCC Part 74
         RSS 210, Issue 9
   9.    Certification
         Shure EMC Laboratory certifies that the information contained in this report was obtained under
         conditions which meet or exceed those specified in the test specifications.
         The data presented in this test report pertains to the EUTs at the test date. Any electrical or
         mechanical modification made to the EUTs subsequent to the specified test date will serve to
         invalidate the data and void this certification.
         This report must not be used by the client to claim product certification, approval, or endorsement by
         NVLAP, NIST, or any agency of the U.S. Government.
   10. Equipment List
                                          Table 10-1: Test Equipment
L# or                                                                    Frequen
           Description        Manufacturer     Model #      Serial #                   Cal Date      Due Date
 ID                                                                      cy Range
L05-
            Modulation                                                    100KHz-
068-                             Boonton         8200     46410-1223                   5/30/2018     5/30/2020
             Analyzer                                                      2GHz
 02
L23-
                                                                          25MHz-
011-    BiConiLog Antenna     ETS Lindgren      3142C        34790                     6/22/2017     6/22/2019
                                                                           3GHz
 15
L23-
                                                                          26MHz-
011-    BiConiLog Antenna     ETS Lindgren      3142C        79899                     8/10/2018     8/10/2020
                                                                           3GHz
 44
L23-
                                                                           1GHz-
011-       Horn Antenna       ETS Lindgren       3117        200363                   10/16/2017     10/16/2019
                                                                           18GHz
 53
L23-
                                                                           1GHz-
011-       Horn Antenna       ETS Lindgren       3117        206583                    4/10/2018     4/10/2020
                                                                           18GHz
 55
L19-
           Temperature
006-                              Espec         SU-240     91004211         N/A        4/5/2018       4/5/2019
            Chamber
 01
L23-
          Audio Signal            Audio          SYS-
021-                                                      48254-1041        N/A        4/26/2018     4/26/2020
        Generator/Analyzer       Precision       2722
 01



        SEL-F-11 Main Body Test Form             Page 7 of 33                          Form Revision: 2
                                                                                              6/9/2017


                                                                  Engineering Test Report No. SEL-038A

L23-
                             Rhode &                                 2Hz-
022-   Spectrum Analyzer                    FSU26      201043                 8/23/2017    8/23/2019
                             Schwarz                               26.5GHz
 01
L23-
                             Rhode &                                 2Hz-
022-   Spectrum Analyzer                    FSW26      103788                 4/24/2018    4/24/2020
                             Schwarz                               26.5GHz
 02
L23-
                             Rhode &         SMF                   100kHz-
023-    Signal Generator                             48254-151                8/23/2017    8/23/2019
                             Schwarz         100A                   22GHz
 01
L23-
                                                     MY5000648     100MHz-
024-   Frequency Counter      Agilent       53220A                            7/24/2018    7/24/2020
                                                         5          6GHz
 01
L23-
          20dB Signal                        BW-
040-                        Mini-Circuits               0952        18GHz     5/31/2018    5/30/2020
           Attenuator                       N20W5+
 03
L23-
040-    ETSI Noise Filter      Shure         N/A            N/A      N/A      5/24/2017    5/24/2019
 22
L23-
041-       Coax Cable       Micro-Coax      W27.16     CP1/X3        N/A      8/29/2018    8/29/2019
 13
                                            UFB311
L23-
                                              A-1-                 25MHz-
041-       Coax Cable          Utiflex               229546-002               5/31/2018    5/31/2019
                                             3188-                 18GHz
 38
                                            50U50U
L23-
           SMA-N-type       Florida RF                             100kHz-
041-                                         N/A     46410-1080               5/30/2018    5/30/2019
          Coaxial Cable        Labs                                 22GHz
 56
L23-
                                             7002-
045-     RF Power Meter      EMPower                  00151071      18GHz     1/31/2018    1/31/2020
                                              006
 36




       SEL-F-11 Main Body Test Form          Page 8 of 33                      Form Revision: 2
                                                                                      6/9/2017


                                                                      Engineering Test Report No. SEL-038A

                                Appendix A: Frequency Stability


A.1. Purpose
    This test was performed to determine if the EUT meets the frequency stability requirements of FCC
    Part 74.861 and RSS 210 Issue 9, Annex G.
A.2. Requirements
    FCC Part 74.861(e)(4) states:
    “The frequency tolerance of the transmitter shall be 0.005 percent.”
    The requirements for RSS 210 Issue 9, Annex G can be found in the table below.




A.3. Measurement Uncertainty
    All measurements are an estimate of their true value. The measurement uncertainty characterizes,
    with a specified confidence level, the spread of values which may be possible for a given
    measurement system.
    Values of Expanded Measurement Uncertainty (95% Confidence):
                                                 Std uncertainty
                                                    ±u(error)
             Expanded Uncertainty
                           (U95):                   5.83E-08
    These values can be found in the document titled ‘Frequency Error_Stability – 2018_09_24.xlsx’
    located at \\shure.com\organization\Quality\Product Conformance-Lab Services\Global
    Compliance\Shure EMC Lab\Controlled Documents\Measurement Uncertainties.
         -   Compliance is deemed to occur if no measured disturbance exceeds the disturbance limit;
         -   Non-compliance is deemed to occur if any measured disturbance exceeds the disturbance limit.
A.4. Test Setup and Instrumentation
    The EUT was heated and cooled in an Espec temperature chamber over a temperature range of
    -30°C to +50°C. The temperature around the EUT was measured and monitored by the built-in
    thermometer. The EUT’s frequency was measured with a spectrum analyzer set to measure signal
    count at 0.1Hz resolution. The center frequency of the spectrum analyzer was set to the selected
    transmit frequency of the EUT (Low, Mid or High). Photographs of the test setup are shown below.
    The test instrumentation can be determined from Table 10-1.
A.5. EUT Operation
    The device was powered on and transmitting. The three frequencies were set using the buttons on
    the device inside the battery door.

  SEL-F-11 Main Body Test Form                Page 9 of 33                         Form Revision: 2
                                                                                          6/9/2017


                                                                 Engineering Test Report No. SEL-038A

A.6. Specific Test Procedures
    The temperature chamber was set to -30°C with the EUT inside and powered on.
    The EUT was allowed to soak for ~20 minutes after the temperature chamber reached the set
    temperature.
    The measured frequency of the transmitter was then recorded in the spreadsheet in section D.7.
    The temperature chamber was incremented +10°C with the EUT inside and powered on.
    Steps c. through e. were repeated until the device reached +50°C.
    Steps a. through e. were repeated for representative low, mid and high frequencies within the EUT’s
    operational bands.
A.7. Results
    The test results can be viewed in the table below.




  SEL-F-11 Main Body Test Form             Page 10 of 33                        Form Revision: 2
                                                                                       6/9/2017


                                                                   Engineering Test Report No. SEL-038A

                       Nominal  Measured            FCC                        RSS
                 Temp Frequency Frequency Deviation Limit Deviation            Limit    Pass/Fail
                  (°C)  (MHz)     (MHz)     (%)     (%)    (ppm)              (ppm)
    572.150MHz
              -30      572.150     572.1499    0.000016   0.005    0.157       ±50       PASS
              -20      572.150     572.1498    0.000028   0.005    0.283       ±50       PASS
              -10      572.150     572.1495    0.000087   0.005    0.874       ±50       PASS
                0      572.150     572.1500    0.000000   0.005    0.002       ±50       PASS
               10      572.150     572.1501    0.000015   0.005    0.150       ±50       PASS
               20      572.150     572.1502    0.000028   0.005    0.280       ±50       PASS
               30      572.150     572.1501    0.000015   0.005    0.150       ±50       PASS
               40      572.150     572.1500    0.000007   0.005    0.073       ±50       PASS
               50      572.150     572.1499    0.000026   0.005    0.255       ±50       PASS
    Room Temp 24.5     572.150     572.1501    0.000021   0.005    0.206       ±50       PASS

    584.125MHz
              -30      584.125     584.12498   0.000003   0.005    0.034       ±50       PASS
              -20      584.125    584.124844   0.000027   0.005    0.267       ±50       PASS
              -10      584.125     584.12488   0.000021   0.005    0.205       ±50       PASS
                0      584.125    584.124989   0.000002   0.005    0.019       ±50       PASS
               10      584.125    584.125093   0.000016   0.005    0.159       ±50       PASS
               20      584.125     584.12516   0.000027   0.005    0.274       ±50       PASS
               30      584.125    584.125093   0.000016   0.005    0.159       ±50       PASS
               40      584.125    584.124955   0.000008   0.005    0.077       ±50       PASS
               50      584.125    584.124853   0.000025   0.005    0.252       ±50       PASS
    Room Temp 24.5     584.125    584.125112   0.000019   0.005    0.192       ±50       PASS

    595.850MHz
              -30      595.850      595.8499   0.000017   0.005    0.168       ±50       PASS
              -20      595.850     595.84983   0.000029   0.005    0.285       ±50       PASS
              -10      595.850     595.84989   0.000018   0.005    0.185       ±50       PASS
                0      595.850    595.849971   0.000005   0.005    0.049       ±50       PASS
               10      595.850    595.850099   0.000017   0.005    0.166       ±50       PASS
               20      595.850    595.850168   0.000028   0.005    0.282       ±50       PASS
               30      595.850    595.850097   0.000016   0.005    0.163       ±50       PASS
               40      595.850    595.849954   0.000008   0.005    0.077       ±50       PASS
               50      595.850     595.84985   0.000025   0.005    0.252       ±50       PASS
    Room Temp 24.5     595.850     595.85012   0.000020   0.005    0.201       ±50       PASS
                        Figure 1: BLX1 H11 Frequency Stability Measurements




SEL-F-11 Main Body Test Form             Page 11 of 33                               Form Revision: 2
                                                                                            6/9/2017


                                                                        Engineering Test Report No. SEL-038A


                  Nominal   Measured                            FCC                 RSS
             Temp Frequency Frequency             Deviation     Limit     Deviation Limit Pass/Fail
             (°C) (MHz)     (MHz)                 (%)           (%)       (ppm)     (ppm)
  F1
             -30     596.125      596.125129      0.000022      0.005     0.216      ±50    PASS
             -20     596.125      596.125201      0.000034      0.005     0.337      ±50    PASS
             -10     596.125      596.125194      0.000033      0.005     0.325      ±50    PASS
             0       596.125      596.125176      0.000030      0.005     0.295      ±50    PASS
             10      596.125      596.125200      0.000034      0.005     0.336      ±50    PASS
             20      596.125      596.125165      0.000028      0.005     0.277      ±50    PASS
             30      596.125      596.125100      0.000017      0.005     0.168      ±50    PASS
             40      596.125      596.125050      0.000008      0.005     0.084      ±50    PASS
             50      596.125      596.125009      0.000002      0.005     0.015      ±50    PASS
  Room
             24.5    596.125      596.125148 0.000025 0.005 0.248                    ±50    PASS
  Temp

  D6
             -30     606.150      606.150198      0.000033      0.005     0.327      ±50    PASS
             -20     606.150      606.150204      0.000034      0.005     0.337      ±50    PASS
             -10     606.150      606.150188      0.000031      0.005     0.310      ±50    PASS
             0       606.150      606.150189      0.000031      0.005     0.312      ±50    PASS
             10      606.150      606.150208      0.000034      0.005     0.343      ±50    PASS
             20      606.150      606.150161      0.000027      0.005     0.266      ±50    PASS
             30      606.150      606.150106      0.000017      0.005     0.175      ±50    PASS
             40      606.150      606.150060      0.000010      0.005     0.099      ±50    PASS
             50      606.150      606.150009      0.000001      0.005     0.015      ±50    PASS
  Room
             24.5    606.150      606.150142 0.000023 0.005 0.234                    ±50    PASS
  Temp

       A8
             -30     615.875      615.875170      0.000028      0.005     0.276      ±50    PASS
             -20     615.875      615.875210      0.000034      0.005     0.341      ±50    PASS
             -10     615.875      615.875194      0.000031      0.005     0.315      ±50    PASS
             0       615.875      615.875188      0.000031      0.005     0.305      ±50    PASS
             10      615.875      615.875212      0.000034      0.005     0.344      ±50    PASS
             20      615.875      615.875165      0.000027      0.005     0.268      ±50    PASS
             30      615.875      615.875103      0.000017      0.005     0.167      ±50    PASS
             40      615.875      615.875052      0.000008      0.005     0.084      ±50    PASS
             50      615.875      615.875008      0.000001      0.005     0.013      ±50    PASS
  Room
             24.5    615.875      615.875149 0.000024 0.005 0.242                    ±50    PASS
  Temp

                          Figure 2: BLX1 J11 Frequency Stability Measurements



A.8. Conclusion
    It was found that the BLX1 H11 and J11 bodypack transmitters passed the requirements of FCC part
    74.861 and RSS 210.9 Annex G.

  SEL-F-11 Main Body Test Form             Page 12 of 33                             Form Revision: 2
                                                                                            6/9/2017


tn n ce


                                                                         Engineering Test Report No. SEL-038A

                              Appendix B: Necessary Bandwidth


B.1. Purpose
    This test was performed to determine if the Shure BLX1 H11 complies with the requirements stated in
    FCC part 74.861 and RSS210 Issue 9, Annex G.
B.2. Requirements
    As stated in paragraph 74.861(7), for low power auxiliary stations operating in the bands allocated for
    TV broadcasting, the following technical requirements apply:
     “Analog emissions within the band from one megahertz below to one megahertz above the carrier
    frequency shall comply with the emission mask in section 8.3.1.2 of the European
    Telecommunications Institute Standard ETSI EN 300 422-1 v1.4.2 (2011-08), Electromagnetic
    compatibility and Radio spectrum Matters (ERM); Wireless microphones in the 25 MHz to 3 GHz
    frequency range; part 1: Technical characteristics and methods of measurement.”




                 Figure 3: Spectrum mask for analogue systems in all bands - ETSI EN 300 422-1

                  The limits for RSS 210 Issue 9, Annex G.3.1 are shown in table G1 below:




  SEL-F-11 Main Body Test Form                 Page 14 of 33                               Form Revision: 2
                                                                                                  6/9/2017


                                                                Engineering Test Report No. SEL-038A

B.3. Measurement Uncertainty
    All measurements are an estimate of their true value. The measurement uncertainty characterizes,
    with a specified confidence level, the spread of values which may be possible for a given
    measurement system.
    Values of Expanded Measurement Uncertainty (95% Confidence):
                              Std uncertainty
                             +u(%)       -u(%)
 Expanded Uncertainty
               (U95):
                            0.130         0.130


    These values can be found in the document titled ‘Occupied Bandwidth Max Input Freq Above
    3kHz.xlsx’ located at \\shure.com\organization\Quality\Product Conformance-Lab Services\Global
    Compliance\Shure EMC Lab\Controlled Documents\Measurement Uncertainties.
B.4. Test Setup and Instrumentation
    Photographs of the test setup are shown below. The test instrumentation can be determined from
    Table 10-1.




  SEL-F-11 Main Body Test Form            Page 15 of 33                        Form Revision: 2
                                                                                      6/9/2017


                                                                 Engineering Test Report No. SEL-038A




B.5. EUT Operation
    The device was powered on and set to three frequencies using the buttons on the front of the device:
    572.125MHz, 584.125MHz, and 595.850MHz.
B.6. Specific Test Procedures
    The device was tested using procedures outlined in EN 300 422-1 part 8.3.2.1 as listed below.
       “The arrangement of test equipment as shown in figure B.1 shall be used. Note that the noise
       meter conforms to (quasi peak) without weighting filter (flat).
       With the Low Frequency (LF) audio signal generator set to 500 Hz, the audio input level to the
       DUT shall be adjusted to 8 dB below the limiting threshold (-8 dB (lim)) as declared by the
       manufacturer.

  SEL-F-11 Main Body Test Form            Page 16 of 33                         Form Revision: 2
                                                                                       6/9/2017


                                                                      Engineering Test Report No. SEL-038A

       The corresponding audio output level from the demodulator shall be measured and recorded.
       The input impedance of the noise meter shall be sufficiently high to avoid more than 0,1 dB
       change in input level when the meter is switched between input and output.
       The audio input level shall be increased by 20 dB, i.e. to +12 dB (lim), and the corresponding
       change in output level shall be measured.
       It shall be checked that the audio output level has increased by ≤ 10 dB.
       If this condition is not met, the initial audio input level shall be increased from -8 dB (lim) in 1 dB
       steps until the above condition is fulfilled, and the input level recorded in the test report. This level
       replaces the value derived from the manufacturer's declaration and is defined as -8 dB (lim).
       Measure the input level at the transmitter required to give +12 dB (lim).
       The LF generator shall be replaced with the weighted noise source to Recommendation ITU-R
       BS.559-2 [i.3], band-limited to 15 kHz as described in IEC 60244-13 [2], and the level shall be
       adjusted such that the measured input to the transmitter corresponds to +12 dB (lim).
       If the transmitter incorporates any ancillary coding or signalling channels (e.g. pilot-tones), these
       shall be enabled prior to any spectral measurements.
       If the transmitter incorporates more than one audio input, e.g. stereo systems, the second and
       subsequent channels shall be simultaneously driven from the same noise source, attenuated to a
       level of -6 dB (lim).
       The transmitter RF output spectrum shall be measured, using a spectrum analyser with the
       following settings:
                ▪   centre frequency: fc: Transmitter (Tx) nominal frequency;
                ▪   dispersion (Span): fc - 1 MHz to fc + 1 MHz;
                ▪   Resolution BandWidth (RBW): 1 kHz;
                ▪   Video BandWidth (VBW): 1 kHz;
                ▪   detector: Peak hold.


       Figure 8 shows the spectrum mask for all analogue systems in the band. The -90 dBc point shall
       be ±1 MHz from fc measured with an average detector. To comply, a measured value shall fall
       below the mask limit.”
    A +12dB level of -28dBV and a -8dB level of -48dBV were chosen using the first set of instructions,
    and the output RF power was measured with inputs of -28dBV for the +12dB level and -46dBV for the
    -6dB level.
B.7. Results
    The necessary bandwidth data are presented on the following pages. Data are shown as the
    maximum relative level of the output level within the emission mask.




  SEL-F-11 Main Body Test Form               Page 17 of 33                            Form Revision: 2
                                                                                             6/9/2017


                                                                 Engineering Test Report No. SEL-038A




                    Figure 4: H11 Necessary Bandwidth results at 572.125MHz




                    Figure 5: H11 Necessary Bandwidth results at 584.125MHz




SEL-F-11 Main Body Test Form           Page 18 of 33                          Form Revision: 2
                                                                                     6/9/2017


                                                                  Engineering Test Report No. SEL-038A




                    Figure 6: H11 Necessary Bandwidth results at 595.850MHz




                     Figure 7: J11 Necessary Bandwidth results at 596.125MHz




SEL-F-11 Main Body Test Form            Page 19 of 33                          Form Revision: 2
                                                                                      6/9/2017


                                                                      Engineering Test Report No. SEL-038A




                         Figure 8: J11 Necessary Bandwidth results at 606.15MHz




                         Figure 9: J11 Necessary Bandwidth results at 615.875MHz



B.8. Conclusion
    It was found that the BLX1 H11 bodypack transmitter passed the requirements of FCC part 74.861,
    FCC part 15.236 and RSS210 Issue 9, Annex G.

  SEL-F-11 Main Body Test Form              Page 20 of 33                          Form Revision: 2
                                                                                          6/9/2017


                                                                           Engineering Test Report No. SEL-038A

                    Appendix C: Field Strength Spurious Emissions


C.1. Purpose
    This test was performed to determine if the BLX1 H11 and J11 meet the spurious emissions
    requirements of FCC Part 74.861 and RSS 210 Issue 9, Annex G.
C.2. Requirements
    FCC Part 74.861 (e)(7) states:
    “Beyond one megahertz below and above the carrier frequency, emissions shall comply with the
    limits specified in section 8.4 of ETSI EN 300 422-1 v1.4.2 (2011-08).”
    RSS 210.9 Annex G.3.4 states:
    “The transmitter unwanted emissions shall meet the requirements in sections 8.3 and 8.4 of ETSI EN
    300 422-1 v1.4.2 (2011-08), Electromagnetic compatibility and radio spectrum matters (ERM);
    Wireless microphones in the 25 MHz to 3 GHz frequency range; Part 1: Technical characteristics and
    methods of measurement.”
    The limits for spurious emissions from a transmitter as stated by EN 300 422-1 v1.4.2 section 8.4 are
    shown below.




                                Figure 10: Table - Limits for Spurious Emissions



C.3. Measurement Uncertainty
    All measurements are an estimate of their true value. The measurement uncertainty characterizes,
    with a specified confidence level, the spread of values which may be possible for a given
    measurement system.
    Values of Expanded Measurement Uncertainty (95% Confidence):


          Measurement Type                                                            ULAB           UFCC
          Radiated disturbance (electric field strength on an open area test
          site or alternative test site) (30 MHz – 1000 MHz)
                                                                                     4.12dB          6dB
          Radiated disturbance (electric field strength on an open area test
          site or alternative test site) (1 GHz – 12.75 GHz)
                                                                                     4.56dB          6dB
         ULAB = Determined for Shure EMC Laboratory
         UFCC = From FCC EN 300 422-1 Table 10: Measurement uncertainty
         Since ULAB is less than or equal to UFCC:
         - Compliance is deemed to occur if no measured disturbance exceeds the disturbance limit;
         - Non-compliance is deemed to occur if any measured disturbance exceeds the disturbance
            limit.




  SEL-F-11 Main Body Test Form                 Page 21 of 33                            Form Revision: 2
                                                                                               6/9/2017


                                                                Engineering Test Report No. SEL-038A

C.4. Test Setup and Instrumentation
    Photographs of the test setup are shown below. The test instrumentation can be determined from
    Table 10-1.




  SEL-F-11 Main Body Test Form           Page 22 of 33                        Form Revision: 2
                                                                                     6/9/2017






                                                                     Engineering Test Report No. SEL-038A




C.5. EUT Operation
    . The device was powered up and the frequency was set using the buttons on the device, with the
    audio gain set to 0. Testing was conducted with the EUT set to the three frequencies chosen within
    the operating frequency range of H11: 572.125MHz, 584.125MHz, and 595.850MHz and J11:
    596.125MHz, 606.150MHz, and 615.875MHz. The device was powered by two AA batteries.
C.6. Specific Test Procedures
    All tests were performed in a 28ft. x 20ft. x 18.5ft. 3m semi-anechoic test chamber. The walls and
    ceiling of the shielded chamber are lined with ferrite tiles. Anechoic absorber material is installed over
    the ferrite tile. The floor of the chamber is used as the ground plane. The chamber complies with
    ANSI C63.4-2003 for site attenuation.


  SEL-F-11 Main Body Test Form               Page 25 of 33                          Form Revision: 2
                                                                                           6/9/2017


                                                                Engineering Test Report No. SEL-038A

 The shielded enclosure prevents emissions from other sources, such as radio and TV stations from
 interfering with the measurements. All power lines and signal lines entering the enclosure pass
 through filters on the enclosure wall. The power line filters prevent extraneous signals from entering
 the enclosure on these leads.




                      BLOCK DIAGRAM OF SHIELDED ENCLOSURE

 Preliminary radiated measurements were performed to determine the frequencies where the
 significant emissions might be found. The broadband measuring antenna was positioned at a 3 meter
 distance from the EUT. The frequency range from 25MHz to 1GHz was investigated using a peak
 detector function with the BiConiLog antenna at horizontal and vertical polarization, and with several
 different orientations of the EUT with respect to the antenna. The maximum levels measured for each
 antenna polarization were then automatically plotted. The resultant field strength (FS) is a summation
 in decibels (dB) of the EMI receiver measurement (ERM), the antenna correction factor (AF), and the
 cable loss factor (CF). If an external pre-amplifier is used, the total is reduced by its gain (-PA).

 Formula 1: FS (dBµV/m) = MTR (dBµV) + AF (dB/m) + CF (dB) + (- PA (dB))

 To convert the Field Strength dBµV/m term to µV/m, the dBµV/m is first divided by 20. The Base 10
 AntiLog is taken of this quotient. The result is the Field Strength value in µV/m terms.

 Formula 2: FS (µV/m) = AntiLog [(FS (dBµV/m))/20]

 Final radiated RF emissions were performed on all significant broadband and narrowband emissions
 found in the preliminary sweeps using the following methods:
       1) Measurements of all significant broadband and narrowband signals from 25MHz to 1GHz
 were made using a quasi-peak detector and a BiConiLog antenna. Measurements above 1GHz were
 made using an average detector and a broadband double ridged waveguide antenna.



SEL-F-11 Main Body Test Form             Page 26 of 33                          Form Revision: 2
                                                                                       6/9/2017


                                                                          Engineering Test Report No. SEL-038A

            2) To ensure that maximum or worst case, emission levels were measured, the following steps
       were taken:
             i.    The EUT was rotated so that all of its sides were exposed to the receiving antenna.
            ii.    Since the measuring antenna is linearly polarized, both horizontal and vertical field
                   components were measured.

       The measuring antenna was raised and lowered from 1 to 4 meters for each antenna polarization to
       maximize the readings.
 C.7. Results
       The substitution data from the radiated emissions tests are presented below.
                                        Substitution Data BLX1 H11
                   Meter                                  Equivalent
Frequency         Reading        Matched Sig. Gen.      Antenna Gain
  (MHz)           (dBµV)           Reading (dBm)             (dB)        Cable Loss (dB)     ERP (dBm)
 572.125          112.41               16.87                 0.00             2.95             13.92
 584.125          112.51               16.40                 0.00             3.06             13.34
 595.850          111.61               14.95                 0.00             2.89             12.06
                        Substitution Data BLX1 H11 (P1) 572.125 Mhz Above 1Ghz
                   Meter                                  Equivalent
Frequency                        Matched Sig. Gen.
                  Reading                               Antenna Gain     Cable Loss (dB)     ERP (dBm)
  (MHz)                            Reading (dBm)
                  (dBµV)                                     (dB)
1444.200           55.47               -43.41                5.20             1.62            -39.83
1716.400           38.70               -69.10                5.60             1.63            -65.13
2288.400           41.11               -62.79                5.70             1.96            -59.05
2860.600           41.84               -64.96                6.90             2.35            -60.41
3432.800           46.66               -69.08                 8.1             2.24            -63.22
4005.000           37.70               -72.00                8.90             2.54            -65.64
                        Substitution Data BLX1 H11 (H5) 584.125 Mhz Above 1Ghz
                   Meter                                  Equivalent
Frequency                        Matched Sig. Gen.
                  Reading                               Antenna Gain     Cable Loss (dB)     ERP (dBm)
  (MHz)                            Reading (dBm)
                  (dBµV)                                     (dB)
1168.200           50.55               -47.98                3.40             1.34            -45.92
1752.000           35.45               -70.00                5.50             1.63            -66.13
2336.600           43.5                -58.39                5.60             1.80            -54.59
2920.600           47.19               -54.30                7.00             2.15            -49.45
3504.800           43.97                 -62                  8.2             2.71            -56.51
4089.000           38.18               -64.00                9.00             2.54            -57.54
                         Substitution Data BLX1 H11 (J9) 595.850 Mhz Above 1Ghz
                   Meter                                  Equivalent
Frequency                        Matched Sig. Gen.
                  Reading                               Antenna Gain     Cable Loss (dB)     ERP (dBm)
  (MHz)                            Reading (dBm)
                  (dBµV)                                     (dB)
1191.800           44.88               -54.93                3.40             1.43            -52.96
1788.000           37.44               -70.00                5.50             1.63            -66.13
2383.400           46.38               -54.90                5.70             2.35            -51.55
2979.600           46.96               -54.60                7.00             2.15            -49.75

     SEL-F-11 Main Body Test Form                 Page 27 of 33                            Form Revision: 2
                                                                                                  6/9/2017


                                                                    Engineering Test Report No. SEL-038A

3575.200      40.95              -66                  8.2                2.71            -60.51
4171.000      38.86            -66.00                 9.20               2.61            -59.41


                                 Substitution Data BLX1 J11
              Meter
Frequency    Reading      Matched Sig. Gen.        Equivalent
  (MHz)      (dBµV)         Reading (dBm)       Antenna Gain (dB) Cable Loss (dB)      ERP (dBm)
 596.125     110.74              13.95                0.00             2.95              11.00
 606.150     108.38              10.69                0.00             3.06              7.63
 615.875     106.18              8.68                 0.00             2.89              5.79
                       Substitution Data BLX1 J11 596 Mhz Above 1Ghz
              Meter
Frequency                 Matched Sig. Gen.        Equivalent
             Reading                                                Cable Loss (dB)    ERP (dBm)
  (MHz)                    Reading (dBm)        Antenna Gain (dB)
             (dBµV)
1192.400      45.57             -50.71               3.40                1.43            -48.74
1788.200      40.28             -57.70               5.50                1.63            -53.83
2384.600      46.92             -49.37               5.70                1.85            -45.52
2980.800      48.93             -48.16               7.00                2.15            -43.31
3576.800      44.84             -52.49               8.20                2.71            -47.00
4173.000      41.04             -57.14               9.20                2.61            -50.55
                       Substitution Data BLX1 J11 606MHz Above 1Ghz
              Meter
Frequency                 Matched Sig. Gen.        Equivalent
             Reading                                                Cable Loss (dB)    ERP (dBm)
  (MHz)                    Reading (dBm)        Antenna Gain (dB)
             (dBµV)
1212.600      38.58             -57.08                3.70               1.41            -54.79
1818.600      38.82             -57.80                4.90               1.91            -54.81
2424.600      42.81             -51.32                5.80               2.11            -47.63
3030.800      45.27             -51.96                7.10               2.21            -47.07
3637.000      45.17             -52.17                8.30               2.41            -46.28
4243.000      39.43             -59.07                9.40               2.81            -52.48
                       Substitution Data BLX1 J11 615 Mhz Above 1Ghz
              Meter
Frequency                 Matched Sig. Gen.        Equivalent
             Reading                                                Cable Loss (dB)    ERP (dBm)
  (MHz)                    Reading (dBm)        Antenna Gain (dB)
             (dBµV)
1231.800      38.81            -57.42                 4.10               1.41            -54.73
1847.800      40.64            -56.85                 4.90               1.91            -53.86
2463.600       47              -49.28                 5.80               2.11            -45.59
3079.400      52.74            -45.35                 7.10               2.21            -40.46
3695.200      42.29             -56.2                 8.30               2.41            -50.31
4311.200      40.84            -57.13                 9.50               2.83            -50.46




     SEL-F-11 Main Body Test Form             Page 28 of 33                           Form Revision: 2
                                                                                             6/9/2017


                                                               Engineering Test Report No. SEL-038A

C.8. Conclusion
    It was found that the BLX1 H11 and J11 bodypack transmitters passed the requirements of FCC part
    74 and RSS 210 Issue 9, Annex G.




  SEL-F-11 Main Body Test Form           Page 29 of 33                       Form Revision: 2
                                                                                    6/9/2017


                                                                    Engineering Test Report No. SEL-038A

                                Appendix D: RF Output Power


D.1. Purpose
    This test was performed to determine if the EUT meets the RF power output requirements of FCC
    Part 74.861 and RSS 210.9.
D.2. Requirements
    As stated in FCC 74.861(e)(1)(ii), For low power auxiliary stations operating in the 600 MHz duplex gap
    and the bands allocated for TV broadcasting, the following technical requirements apply: The power may
    not exceed the following values. (ii) 470-608 and 614-698: 250 mW conducted power
    As stated in RSS 210.9 Annex G, transmitter EIRP shall be limited to the values listed in Table G1
    below, or 250 mW.




D.3. Measurement Uncertainty
    All measurements are an estimate of their true value. The measurement uncertainty characterizes,
    with a specified confidence level, the spread of values which may be possible for a given
    measurement system.
    Values of Expanded Measurement Uncertainty (95% Confidence):
                                                       Std uncertainty
                                                       +u(dB)               -u(dB)
                       Expanded
                    Uncertainty (U95):
                                                       0.461                0.461
    These values can be found in the document titled ‘Carrier Power w ETS Power Meter (L23-045-
    36).xlsx’ located at \\shure.com\organization\Quality\Product Conformance-Lab Services\Global
    Compliance\Shure EMC Lab\Controlled Documents\Measurement Uncertainties.


D.4. Test Setup and Instrumentation
    Photographs of the test setup are shown below. The test instrumentation can be determined from
    Table 10-1.




  SEL-F-11 Main Body Test Form              Page 30 of 33                          Form Revision: 2
                                                                                          6/9/2017


                                               Engineering Test Report No. SEL-038A




SEL-F-11 Main Body Test Form   Page 31 of 33                Form Revision: 2
                                                                   6/9/2017


                                                                Engineering Test Report No. SEL-038A




D.5. EUT Operation
    The EUT was powered up and the transmit frequencies (572.125MHz, 584.125MHz, and
    595.850MHz and J11: 596.125MHz, 606.150MHz, and 615.875MHz) were selected using the front
    panel controls.
D.6. Specific Test Procedures
     a.   The EUT’s RF output was connected to an artificial antenna at ambient temperature.
     b.   The EUT’s frequency was set at the first test frequency.
     c.   The power level was measured and recorded.
     d.   Steps b and c were repeated at the other test frequencies.
     e.   The cable loss and antenna gain were recorded and factored into the measured power data
          using the equation below:




D.7. Results
    The results of the power output test can be seen below.
                                   Nominal    Measured    Measured   Measured
                      Frequency                                                    FCC Limit        RSS Limit
                                    Power      Power       Power       Power
  Unit#                  (MHz)      (mW)       (dBm)       (mW)      (mW EIRP)       (mW)       (mW EIRP)
                        572.150       10       11.14       13.00       13.48          250         250
  RF Out1    H11        584.125       10       10.79       11.99       12.35          250         250
                        595.850       10       10.21       10.50       10.86          250         250




  SEL-F-11 Main Body Test Form            Page 32 of 33                          Form Revision: 2
                                                                                        6/9/2017


                                                               Engineering Test Report No. SEL-038A

                                  Nominal   Measured     Measured   Measured
                     Frequency                                       Power         FCC Limit       RSS Limit
                                   Power     Power        Power
  Unit#                (MHz)       (mW)      (dBm)        (mW)      (mW EIRP)        (mW)      (mW EIRP)
                      596.125        10      10.69        11.72       12.51           250        250
  RF Out1   J11       606.150        10      10.00        10.00       10.79           250        250
                      615.875        10       9.11         8.15       8.94            250        250


D.8. Conclusion
    It was found that the BLX1 H11 and J11 bodypack transmitters passed the requirements of RSS
    210.9 and FCC 74.861(e)(1)(ii).




  SEL-F-11 Main Body Test Form           Page 33 of 33                          Form Revision: 2
                                                                                       6/9/2017



Document Created: 2019-07-12 09:19:10
Document Modified: 2019-07-12 09:19:10

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC