Test report

FCC ID: CWTWB1G744

Test Report

Download: PDF
FCCID_1679299

                                                                                          Test report No.   : 32EE0264—HO—02—A
                                                                                          Page              : 1 of 17
                                                                                          Issued date       : April 4, 2012
                                                                                          FCC ID            : CWTWB1G744




                                   RADIO TEST REPORT
                                   Test Report No. : 32EE0264—HO—02—A
        Applicant                               :        Alps Electric Co., Ltd.

        Type of Equipment                       :        Passive Entry System (Hand Unit)

        Model No.                               :        TWB1G744

        Test regulation                                  FCC Part 15 Subpart C: 2012

        FCC ID                                           CWTWB1G744

        Test Result                                      Complied


                     This test report shall not be reproduced in full or partial, without the written approval of UL Japan, Inc.
          in j o p




                     The results in this report apply only to the sample tested.
                     This sample tested is in compliance with above regulation.
                     The test results in this report are traceable to the national or international standards.
                     This test report must not be used by the customer to claim product certification, approval, or endorsement
                     by NVLAP, NIST, or any agency of the Federal Government.


                             Date of test:                       March 4 and 9, 2012

                             Representative test
                             engineer:
                                                                 Toy/aka Sasagavx;a
                                                               Engin‘éer of WiSE Japan,
                                                               UL Verification Service



                             Approved by:                  %%\ _>
                                                     w           Masanori Nishi
                                                               Leader of WiSEJapan,
                                                               UL Verification Service



                                                                 This laboratory is accredited by the NVLAP LAB CODE
                                                    ®©           200572—0, U.S.A. The tests reported herein have been
                                                                 performed in accordance with its terms of accreditation.
                                                                 *As for the range of Accreditation in NVLAP, you may
                                                                 refer to the WEB address,
                                                                 http://www.ul.com/japan/jpn/pages/services/eme/about/ma
                                                                 rk1/index.jsp#nvlap
          NVLAP LAB CODE: 200572—0




UL Japan, Inc.
Head Office EMC Lab.
4383—326 Asama—cho, Ise—shi, Mie—ken 516—0021 JAPAN
Telephone        : +81 596 24 8116                                                                      13—EM—FO429
Facsimile        : +81 596 24 8124


                                                                                                       Test report No.        : 32EE0264-HO-02-A
                                                                                                       Page                   : 2 of 17
                                                                                                       Issued date            : April 4, 2012
                                                                                                       FCC ID                 : CWTWB1G744



CONTENTS                                                                                                                                  PAGE

SECTION 1: Customer information ·············································································· 3
SECTION 2: Equipment under test (E.U.T.) ···································································· 3
SECTION 3: Test specification, procedures & results························································· 4
SECTION 4: Operation of E.U.T. during testing ······························································· 7
SECTION 5: Radiated emission (Electric Field Strength of Fundamental and Spurious Emission) 8
SECTION 6: Automatically deactivate ········································································· 10
SECTION 7: -20dB and 99% Occupied Bandwidth ························································· 10
APPENDIX 1: Data of EMI test ·················································································· 11
    Automatically deactivate................................................................................................................... 11
    Radiated Emission (Electric Field Strength of Fundamental and Spurious Emission) ..................... 12
    -20dB and 99% Occupied Bandwidth ............................................................................................... 13
APPENDIX 2: Test Instruments ·················································································· 14
APPENDIX 3: Photographs of test setup ······································································· 15
    Radiated emission ............................................................................................................................. 15
    Worst Case Position .......................................................................................................................... 16




UL Japan, Inc.
Head Office EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone       : +81 596 24 8116
Facsimile       : +81 596 24 8124


                                                                               Test report No.   : 32EE0264-HO-02-A
                                                                               Page              : 3 of 17
                                                                               Issued date       : April 4, 2012
                                                                               FCC ID            : CWTWB1G744



SECTION 1: Customer information
Company Name                           :    Alps Electric Co., Ltd.
Address                                :    6-3-36, Nakazato, Furukawa, Osaki-city, Miyagi-pref, 989-6181, Japan
Telephone Number                       :    +81-229-23-5111
Facsimile Number                       :    +81-229-22-3755
Contact Person                         :    Toru Kinoshita



SECTION 2: Equipment under test (E.U.T.)
2.1     Identification of E.U.T.

Type of Equipment                      :    Passive Entry System (Hand Unit)
Model No.                              :    TWB1G744
Serial No.                             :    Refer to Section 4, Clause 4.2
Receipt Date of Sample                 :    January 28, 2012
Country of Mass-production             :    Japan
Condition of EUT                       :    Production prototype
                                            (Not for Sale: This sample is equivalent to mass-produced items.)
Modification of EUT                    :    No Modification by the test lab


2.2     Product Description

Model No: TWB1G744 (referred to as the EUT in this report) is the Passive Entry System (Hand Unit).

General Specification
Feature of EUT                     :        The Hand Unit receives LF signal from I-KEY unit installed in vehicle,
                                            transmits RF signal and performs locking and unlocking of a door and an
                                            engine start.
                                            Or, it transmits RF signal by being pushed button, and performs locking
                                           and unlocking of a door and an engine start.
Clock frequency in the system      :        2MHz (CPU)

Radio Specification
(Transmitter part)
Equipment Type                     :       Transceiver
Frequency of operation             :       433.92MHz
Type of modulation                 :       FSK
Antenna Type                       :       PCB Pattern antenna
Method of Frequency Generation     :       SAW Resonator
Operating voltage (inner)          :       DC 3.0V
Operating Temperature              :       -10 to +60 deg. C

(Receiver part)
Frequency of operation             :       125kHz
Antenna Type                       :       Loop Coil and Bar Antenna
Operating voltage (inner)          :       DC 3.0V
Operating Temperature              :       -10 to +60 deg. C




UL Japan, Inc.
Head Office EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone       : +81 596 24 8116
Facsimile       : +81 596 24 8124


                                                                                          Test report No.      : 32EE0264-HO-02-A
                                                                                          Page                 : 4 of 17
                                                                                          Issued date          : April 4, 2012
                                                                                          FCC ID               : CWTWB1G744



 SECTION 3: Test specification, procedures & results

 3.1      Test Specification


 Test Specification                    :    FCC Part 15 Subpart C: 2012, final revised on February 1, 2012

 Title                                 :    FCC 47CFR Part15 Radio Frequency Device Subpart C Intentional Radiators
                                            Section 15.231 Periodic operation in the band 40.66 - 40.70MHz
                                            and above 70MHz


 3.2      Procedures and results

Item                       Test Procedure              Specification               Worst margin     Results        Remarks
                           FCC: ANSI C63.4:2003        FCC: Section 15.207
                           7. AC powerline conducted
                           emission measurements
Conducted emission                                                                 N/A              N/A*1)         -
                           IC: RSS-Gen 7.2.4           IC: RSS-Gen 7.2.4


                           FCC: ANSI C63.4:2003        FCC: Section 15.231(a)(1)
                           13. Measurement of
Automatically Deactivate   intentional radiators                                   N/A              Complied       Radiated
                           IC: -                       IC: RSS-210 A1.1.1

                           FCC: ANSI C63.4:2003        FCC: Section 15.231(b)      1.5dB
                           13. Measurement of                                      433.92MHz
Electric Field Strength
                           intentional radiators                                   Horizontal       Complied       Radiated
of Fundamental Emission
                           IC: RSS-Gen 4.8             IC: RSS-210 A1.1.2          (PK, AV limit)
                                                                                   *2)
                           FCC: ANSI C63.4:2003        FCC: Section 15.205         8.2dB
                           13. Measurement of                Section 15.209        3905.28MHz
Electric Field Strength    intentional radiators             Section 15.231(b)     Horizontal       Complied       Radiated
of Spurious Emission
                           IC: RSS-Gen 4.9             IC: RSS-210 A1.1.2, 2.5.1   (PK, AV limit)
                                                           RSS-Gen 7.2.5           *2)
                           FCC: ANSI C63.4:2003        FCC: Section 15.231(c)
                           13. Measurement of
-20dB Bandwidth            intentional radiators                                   N/A              Complied       Radiated
                           IC: -                       IC: Reference data

Note: UL Japan, Inc.’s EMI Work Procedures No. 13-EM-W0420 and 13-EM-W0422.
*1) The test is not applicable since the EUT does not have AC Mains.
*2) The test was performed with severer PK detection for average limit.

 FCC 15.31 (e)
 This test was performed with the New Battery (DC 3.0V) and the constant voltage was supplied to the EUT during the
 tests. Therefore, the EUT complies with the requirement.

 FCC Part 15.203 Antenna requirement
 It is impossible for end users to replace the antenna, because the antenna is mounted inside of the EUT. Therefore, the
 equipment complies with the antenna requirement of Section 15.203.




 UL Japan, Inc.
 Head Office EMC Lab.
 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
 Telephone       : +81 596 24 8116
 Facsimile       : +81 596 24 8124


                                                                                              Test report No.       : 32EE0264-HO-02-A
                                                                                              Page                  : 5 of 17
                                                                                              Issued date           : April 4, 2012
                                                                                              FCC ID                : CWTWB1G744



3.3       Addition to standard

Item                         Test Procedure       Specification             Worst margin         Results        Remarks
99% Occupied
                             IC: RSS-Gen 4.6.1    IC: RSS-Gen 4.6.1         N/A                  Complied       Radiated
Bandwidth
Other than above, no addition, exclusion nor deviation has been made from the standard.

3.4       Uncertainty

EMI
The following uncertainties have been calculated to provide a confidence level of 95% using a coverage factor k=2.
   Test room                  Radiated emission
   (semi-                        (10m*)(+dB)
   anechoic
   chamber)
                     9kHz             30MHz         300MHz
                   -30MHz            -300MHz         -1GHz
   No.1             4.1dB              5.0dB         4.8dB
   No.2                -                  -             -
   No.3                -                  -             -
   No.4                -                  -             -
*10m = Measurement distance

      Test room                                               Radiated emission
      (semi-                       (3m*)(+dB)                                      (1m*)(+dB)               (0.5m*)(+dB)
      anechoic      9kHz       30MHz      300MHz                   1GHz        10GHz       18GHz               26.5GHz
      chamber)    -30MHz      -300MHz -1GHz                       -10GHz      -18GHz      -26.5GHz             -40GHz
   No.1            4.2dB        5.0dB      5.1dB                   4.7dB       5.7dB        4.4dB               4.3dB
   No.2            4.1dB        5.2dB      5.1dB                   4.8dB       5.6dB        4.3dB               4.2dB
   No.3            4.5dB        5.0dB      5.2dB                   4.8dB       5.6dB        4.5dB               4.2dB
   No.4            4.7dB        5.2dB      5.2dB                   4.8dB       5.6dB        5.1dB               4.2dB
*3m/1m/0.5m = Measurement distance

Radiated emission test(3m)
[Electric Field Strength of Fundamental Emission]
The data listed in this report meets the limits unless the uncertainty is taken into consideration.

[Electric Field Strength of Spurious Emission]
The data listed in this test report has enough margin, more than the site margin.




UL Japan, Inc.
Head Office EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone       : +81 596 24 8116
Facsimile       : +81 596 24 8124


                                                                                    Test report No.    : 32EE0264-HO-02-A
                                                                                    Page               : 6 of 17
                                                                                    Issued date        : April 4, 2012
                                                                                    FCC ID             : CWTWB1G744



3.5      Test Location

UL Japan, Inc. Head Office EMC Lab. *NVLAP Lab. code: 200572-0
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8116          Facsimile : +81 596 24 8124
                        FCC           IC Registration    Width x Depth x      Size of                        Other
                        Registration Number              Height (m)           reference ground plane (m) /   rooms
                        Number                                                horizontal conducting plane
 No.1 semi-anechoic     313583        2973C-1            19.2 x 11.2 x 7.7m   7.0 x 6.0m                     No.1 Power
 chamber                                                                                                     source room
 No.2 semi-anechoic     655103        2973C-2            7.5 x 5.8 x 5.2m     4.0 x 4.0m                     -
 chamber
 No.3 semi-anechoic     148738        2973C-3            12.0 x 8.5 x 5.9m    6.8 x 5.75m                    No.3
 chamber                                                                                                     Preparation
                                                                                                             room
 No.3 shielded room    -              -                  4.0 x 6.0 x 2.7m     N/A                            -
 No.4 semi-anechoic    134570         2973C-4            12.0 x 8.5 x 5.9m    6.8 x 5.75m                    No.4
 chamber                                                                                                     Preparation
                                                                                                             room
 No.4 shielded room    -              -                  4.0 x 6.0 x 2.7m     N/A                            -
 No.5 semi-anechoic    -              -                                                                      -
                                                         6.0 x 6.0 x 3.9m     6.0 x 6.0m
 chamber
 No.6 shielded         -              -                  4.0 x 4.5 x 2.7m     4.75 x 5.4 m                   -
 room
 No.6 measurement      -              -                  4.75 x 5.4 x 3.0m    4.75 x 4.15 m                  -
 room
 No.7 shielded room    -              -                  4.7 x 7.5 x 2.7m     4.7 x 7.5m                     -
 No.8 measurement       -              -               3.1 x 5.0 x 2.7m      N/A                             -
 room
 No.9 measurement       -              -               8.0 x 4.5 x 2.8m      2.0 x 2.0m                      -
 room
 No.10 measurement      -              -               2.6 x 2.8 x 2.5m      2.4 x 2.4m                      -
 room
 No.11 measurement      -              -               3.1 x 3.4 x 3.0m      2.4 x 3.4m                      -
 room
* Size of vertical conducting plane (for Conducted Emission test) : 2.0 x 2.0m for No.1, No.2, No.3, and     No.4 semi-anechoic
chambers and No.3 and No.4 shielded rooms.



3.6    Data of EMI, Test instruments, and Test set up.

Refer to APPENDIX.




UL Japan, Inc.
Head Office EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone       : +81 596 24 8116
Facsimile       : +81 596 24 8124


                                                                                Test report No.     : 32EE0264-HO-02-A
                                                                                Page                : 7 of 17
                                                                                Issued date         : April 4, 2012
                                                                                FCC ID              : CWTWB1G744



SECTION 4: Operation of E.U.T. during testing

4.1      Operating Modes
Test Item*                                             Mode
Automatically Deactivate                               Normal use mode
Duty Cycle
Electric Field Strength of Fundamental Emission        Transmitting mode (Tx)
Electric Field Strength of Spurious Emission
-20dB & 99% Occupied Bandwidth
* The system was configured in typical fashion (as a customer would normally use it) for testing.


4.2 Configuration and peripherals



                                                            A:EUT




                                   * Test data was taken under worse case conditions.

Description of EUT
 No. Item                         Model number        Serial number            Manufacturer               Remarks
 A    Passive Entry System        TWB1G744            12012702 *1)             Alps Electric Co., Ltd.    EUT
      (Hand Unit)                                     12012701 *2)
*1) Used for Normal use mode
*2) Used for Transmitting mode




UL Japan, Inc.
Head Office EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone       : +81 596 24 8116
Facsimile       : +81 596 24 8124


                                                                                Test report No.   : 32EE0264-HO-02-A
                                                                                Page              : 8 of 17
                                                                                Issued date       : April 4, 2012
                                                                                FCC ID            : CWTWB1G744



SECTION 5:          Radiated emission (Electric Field Strength of Fundamental and Spurious
Emission)
Test Procedure and conditions

EUT was placed on a urethane platform of nominal size, 0.5m by 1.0m, raised 0.8m above the conducting ground plane.
The EUT was set on the center of the tabletop.
Test was made with the antenna positioned in both the horizontal and vertical planes of polarization. The measurement
antenna was varied in height above the conducting ground plane to obtain the maximum signal strength.
Photographs of the set up are shown in Appendix 3.

[Transmitting mode]

The Radiated Electric Field Strength has been measured on Semi anechoic chamber with a ground plane and at a distance
of 3m.
The measuring antenna height was varied between 1 and 4m (frequency 9kHz – 30MHz: loop antenna was fixed height
at 1.0m) and EUT was rotated a full revolution in order to obtain the maximum value of the electric field strength.
The measurements were performed for both vertical and horizontal antenna polarization.
The radiated emission measurements were made with the following detector function of the test receiver/spectrum
analyzer.
*Refer to Figure 1 about Direction of the Loop Antenna.

Test Antennas are used as below;
   Frequency          Below 30MHz             30MHz to 300MHz        300MHz to 1GHz           Above 1GHz
   Antenna Type       Loop                    Biconical              Logperiodic              Horn

                      From 9kHz to           From           From          From           From 30MHz     Above 1GHz
                       90kHz and           90kHz to       150kHz        490kHz to          to 1GHz      *1)
                     From 110kHz to         110kHz       to 490kHz       30MHz
                         150kHz
   Detector               Peak               Peak          Peak            Peak            Peak *2)         Peak *2)
   Type
   IF                    200Hz              200Hz          9kHz            9kHz             120kHz      PK: S/A:RBW
   Bandwidth                                                                                            1MHz,
                                                                                                        VBW:3MHz
 *For the test below 30MHz, the noise was not detected when it was confirmed with PK detect.
*1) The Spectrum Analyzer was used in 3dB resolution bandwidth.
*2) Average emission measurements were not calculated with PK detect and Duty cycle factor since the PK
measurement value did not exceed the AV limit.

- The carrier level was measured at each position of all three axes X, Y and Z, and the position that has the maximum
noise was determined.
Noise levels of all the frequencies were measured at the position.
This EUT has two modes which mechanical key is folded in or out. The worst case was confirmed that mechanical key is
folded in and out, as a result, the test which mechanical key was folded out was the worst case. Therefore the test was
performed under the worst condition.

*The result is rounded off to the second decimal place, so some differences might be observed.

Measurement range                  : 9kHz-3.2GHz
Test data                          : APPENDIX
Test result                        : Pass




UL Japan, Inc.
Head Office EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone       : +81 596 24 8116
Facsimile       : +81 596 24 8124


                                                                       Test report No.   : 32EE0264-HO-02-A
                                                                       Page              : 9 of 17
                                                                       Issued date       : April 4, 2012
                                                                       FCC ID            : CWTWB1G744



Figure 1: Direction of the Loop Antenna


  Side View (Vertical)


        EUT




  Top View (Horizontal)




        EUT




                                          Antenna was not rotated.


 Top View (Vertical)


                                           135deg

       EUT                                90deg

                                            45deg
                                                    0deg


                                        Front side: 0 deg.
                                        Forward direction: clockwise




UL Japan, Inc.
Head Office EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone       : +81 596 24 8116
Facsimile       : +81 596 24 8124


                                                                                              Test report No.    : 32EE0264-HO-02-A
                                                                                              Page               : 10 of 17
                                                                                              Issued date        : April 4, 2012
                                                                                              FCC ID             : CWTWB1G744


SECTION 6: Automatically deactivate

Test Procedure

The measurement was performed with Electric field strength using a spectrum analyzer.

Test data                                 : APPENDIX
Test result                               : Pass



SECTION 7: -20dB and 99% Occupied Bandwidth
Test Procedure

The measurement was performed in the antenna height to gain the maximum of Electric field strength.

Test              Span                      RBW           VBW            Sweep                Detector Trace          Instrument used
20dB Bandwidth 500kHz                     15kHz           47kHz          Auto                  Peak       Max Hold    Spectrum Analyzer
99% Occupied     Enough width to display 1 % of Span Three times Auto                          Peak *1)   Max Hold    Spectrum Analyzer
Bandwidth        20dB Bandwidth                           of RBW                                          *1)
*1) The measurement was performed with Peak detector, Max Hold since the duty cycle was not 100%.

Test data                                 : APPENDIX
Test result                               : Pass




UL Japan, Inc.
Head Office EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone       : +81 596 24 8116
Facsimile       : +81 596 24 8124


                                                                              Test report No.     : 32EE0264-HO-02-A
                                                                              Page                : 11 of 17
                                                                              Issued date         : April 4, 2012
                                                                              FCC ID              : CWTWB1G744



APPENDIX 1: Data of EMI test

                                             Automatically deactivate
                     Test place                 Head Office EMC Lab. No.3 Semi Anechoic Chamber
                     Report No.                 32EE0264-HO-02
                     Date                       03/09/2012
                     Temperature/ Humidity      23 deg. C / 36% RH
                     Engineer                   Tomotaka Sasagawa
                     Mode                       Transmitting mode


                             Time of                       Limit                   Result
                           Transmitting
                              [sec]                        [sec]
                               0.35                        5.00                     Pass




UL Japan, Inc.
Head Office EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone       : +81 596 24 8116
Facsimile       : +81 596 24 8124


                                                                                                                   Test report No.            : 32EE0264-HO-02-A
                                                                                                                   Page                       : 12 of 17
                                                                                                                   Issued date                : April 4, 2012
                                                                                                                   FCC ID                     : CWTWB1G744



        Radiated Emission (Electric Field Strength of Fundamental and Spurious Emission)
                             Test place                              Head Office EMC Lab. No.3 Semi Anechoic Chamber
                             Report No.                              32EE0264-HO-02
                             Date                                    03/04/2012
                             Temperature/ Humidity                   22 deg. C / 48% RH
                             Engineer                                Tomotaka Sasagawa
                             Mode                                    Transmitting mode
            PK Limit
             Frequency       Detector        Reading         Ant      Loss       Gain          Result       Limit          Margin                 Remark
                                             [dBuV]         Factor                           [dBuV/m]                       [dB]             Inside or Outside
               [MHz]                      Hor      Ver     [dB/m]     [dB]       [dB]     Hor         Ver [dBuV/m]      Hor      Ver       of Restricted Bands
                 433.920 PK                82.5      79.5     17.9      10.9       32.0      79.3      76.3  100.8       21.5     24.5   Carrier
                 867.840 PK                31.7      30.6     22.3      13.3       31.2     36.1       35.0   80.8       44.7     45.8   Outside
                1301.760 PK                47.3      47.5     24.8       1.9       33.9     40.1       40.3   73.9       33.8     33.6   Inside
                1735.680 PK                48.1      53.1     25.8       2.1       32.9     43.1       48.1   80.8       37.7     32.7   Outside
                2169.600 PK                45.9      45.5     27.1       2.4       32.3     43.1       42.7   80.8       37.7     38.1   Outside
                2603.520 PK                43.9      44.0     28.6       2.6       32.1     43.0       43.1   80.8       37.8     37.7   Outside
                3037.440 PK                43.3      43.6     28.7       2.8       31.9     42.9       43.2   80.8       37.9     37.6   Outside
                3471.360 PK                43.5      42.9     28.9       3.1       31.8     43.7       43.1   80.8       37.1     37.7   Outside
                3905.280 PK                44.2      42.6     29.8       3.3       31.6     45.7       44.1   73.9       28.2     29.8   Inside
                4339.200 PK                42.8      42.4     30.2       3.5       31.5     45.0       44.6   73.9       28.9     29.3   Inside
            Result = Reading + Ant Factor + Loss (Cable+Attenuator+Filter) - Gain(Amprifier)



            AV Limit
             Frequency       Detector        Reading         Ant      Loss       Gain          Result         Limit          Margin                Remark
                                             [dBuV]         Factor                           [dBuV/m]                         [dB]
               [MHz]                      Hor      Ver     [dB/m]     [dB]       [dB]     Hor         Ver [dBuV/m] Hor              Ver
                 433.920 PK                82.5      79.5     17.9      10.9       32.0     79.3       76.3     80.8        1.5        4.5 Carrier
                 867.840 PK                31.7      30.6     22.3      13.3       31.2     36.1       35.0     60.8       24.7      25.8 Outside
                1301.760 PK                47.3      47.5     24.8       1.9       33.9     40.1       40.3     53.9       13.8      13.6 Inside
                1735.680 PK                48.1      53.1     25.8       2.1       32.9     43.1       48.1     60.8       17.7      12.7 Outside
                2169.600 PK                45.9      45.5     27.1       2.4       32.3     43.1       42.7     60.8       17.7      18.1 Outside
                2603.520 PK                43.9      44.0     28.6       2.6       32.1     43.0       43.1     60.8       17.8      17.7 Outside
                3037.440 PK                43.3      43.6     28.7       2.8       31.9     42.9       43.2     60.8       17.9      17.6 Outside
                3471.360 PK                43.5      42.9     28.9       3.1       31.8     43.7       43.1     60.8       17.1      17.7 Outside
                3905.280 PK                44.2      42.6     29.8       3.3       31.6     45.7       44.1     53.9        8.2        9.8 Inside
                4339.200 PK                42.8      42.4     30.2       3.5       31.5     45.0       44.6     53.9        8.9        9.3 Inside
            Result = Reading + Ant Factor + Loss (Cable+Attenuator+Filter) - Gain(Amprifier) + Duty factor (Refer to Duty factor data sheet)

            *Other frequency noises omitted in this report were not seen or had enough margin (more than 20dB).

*Average emission measurements were not calculated with PK detect and Duty cycle factor since the PK measurement value did not exceed the AV
limit.




UL Japan, Inc.
Head Office EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone       : +81 596 24 8116
Facsimile       : +81 596 24 8124


                                                                                Test report No.   : 32EE0264-HO-02-A
                                                                                Page              : 13 of 17
                                                                                Issued date       : April 4, 2012
                                                                                FCC ID            : CWTWB1G744




                                    -20dB and 99% Occupied Bandwidth
                     Test place                 Head Office EMC Lab. No.3 Semi Anechoic Chamber
                     Report No.                 32EE0264-HO-02
                     Date                       03/09/2012
                     Temperature/ Humidity      23 deg. C / 36% RH
                     Engineer                   Tomotaka Sasagawa
                     Mode                       Transmitting mode


                   Bandwidth Limit : Fundamental Frequency   433.92 MHz x 0.25% = 1084.80 kHz

                         -20dB Bandwidth         Bandwidth Limit       Result
                              [kHz]                  [kHz]
                             145.97                 1084.80             Pass

                     99% Occupied Bandwidth      Bandwidth Limit       Result
                             [kHz]                   [kHz]
                            131.49                  1084.80             Pass



                      -20dB BW                                                        99% BW




UL Japan, Inc.
Head Office EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone       : +81 596 24 8116
Facsimile       : +81 596 24 8124


                                                                                  Test report No.   : 32EE0264-HO-02-A
                                                                                  Page              : 14 of 17
                                                                                  Issued date       : April 4, 2012
                                                                                  FCC ID            : CWTWB1G744




APPENDIX 2: Test Instruments

EMI test equipment
 Control No.       Instrument          Manufacturer        Model No         Serial No      Test Item Calibration Date *
                                                                                                      Interval(month)
  MAEC-03      Semi Anechoic         TDK               Semi Anechoic    DA-10005           RE        2012/02/24 * 12
               Chamber(NSA)                            Chamber 3m
   MOS-13      Thermo-Hygrometer     Custom            CTH-180          -                  RE        2012/02/06 * 12
   MJM-06      Measure               PROMART            SEN1955         -                  RE        -
 COTS-MEMI EMI measurement           TSJ               TEPTO-DV         -                  RE        -
           program
   MSA-05  Spectrum Analyzer         Advantest         R3273            160400285          RE        2011/11/23 * 12
   MTR-08      Test Receiver         Rohde & Schwarz   ESCI             100767             RE        2011/08/11 * 12
   MBA-03      Biconical Antenna     Schwarzbeck       BBA9106          1915               RE        2011/10/15 * 12
   MLA-03      Logperiodic Antenna   Schwarzbeck       USLP9143         174                RE        2011/10/15 * 12
   MCC-51      Coaxial cable         UL Japan          -                -                  RE        2011/07/15 * 12
   MAT-09      Attenuator(6dB)       Weinschel Corp    2                BK7973             RE        2011/11/02 * 12
   MPA-13      Pre Amplifier         SONOMA            310              260834             RE        2012/03/16 * 12
                                     INSTRUMENT
  MAEC-04      Semi Anechoic         TDK               Semi Anechoic    DA-10005           RE        2012/02/29 * 12
               Chamber(NSA)                            Chamber 3m
   MOS-15      Thermo-Hygrometer     Custom            CTH-180          -                  RE        2012/02/06 * 12
   MJM-07      Measure               PROMART            SEN1955         -                  RE        -
   MHA-21      Horn Antenna 1-       Schwarzbeck       BBHA9120D        9120D-557          RE        2011/08/11 * 12
               18GHz
   MCC-56      Microwave Cable       Suhner            SUCOFLEX104 270875/4(1m) / RE                 2011/03/02 * 12
                                                                        284655(5m)
   MPA-12      MicroWave System      Agilent           83017A           MY39500780         RE        2011/03/10 * 12
               Amplifier
  MLPA-01      Loop Antenna          Rohde & Schwarz   HFH2-Z2          100017             RE        2011/10/19 * 12
   MCC-30      Coaxial cable         UL Japan          -                -                  RE        2011/07/28 * 12


The expiration date of the calibration is the end of the expired month.
All equipment is calibrated with valid calibrations. Each measurement data is traceable to the national or
international standards.

As for some calibrations performed after the tested dates, those test equipment have been controlled by means of
an unbroken chains of calibrations.

Test Item:
RE: Radiated emission, 99% Occupied Bandwidth, -20dB bandwidth , Automatically deactivate and Duty cycle tests




UL Japan, Inc.
Head Office EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone       : +81 596 24 8116
Facsimile       : +81 596 24 8124



Document Created: 2012-04-04 09:46:56
Document Modified: 2012-04-04 09:46:56

© 2024 FCC.report