03 FCC Test Report_DSC

FCC ID: CWTWB1G0169

Test Report

Download: PDF
FCCID_4079580

                                                                                         Test report No.     : 12584793H-R1
                                                                                         Page                : 1 of 20
                                                                                         Issued date         : November 21, 2018
                                                                                         FCC ID              : CWTWB1G0169



                               RADIO TEST REPORT
                               Test Report No. : 12584793H-R1
        Applicant                            :     Alps Electric Co., Ltd.

        Type of Equipment                    :     Passive Entry System

        Model No.                            :     TWB1G0169

        Test regulation                      :     FCC Part 15 Subpart C: 2018

        FCC ID                               :     CWTWB1G0169

        Test Result                          :     Complied
           1.   This test report shall not be reproduced in full or partial, without the written approval of UL Japan, Inc.
           2.   The results in this report apply only to the sample tested.
           3.   This sample tested is in compliance with the above regulation.
           4.   The test results in this report are traceable to the national or international standards.
           5.   This test report must not be used by the customer to claim product certification, approval, or
                endorsement by NVLAP, NIST, or any agency of the Federal Government.
           6.   This test report covers Radio technical requirements. It does not cover administrative issues
                such as Manual or non-Radio test related Requirements. (if applicable)
           7.   The all test items in this test report are conducted by UL Japan, Inc. Ise EMC Lab.
           8.   This report is a revised version of 12584793H. 12584793H is replaced with this report.

                         Date of test:                          November 13, 2018

                         Representative test
                         engineer:
                                                                Yuta Moriya
                                                                  Engineer
                                                         Consumer Technology Division


                         Approved by:
                                                              Shinichi Miyazono
                                                                   Engineer
                                                         Consumer Technology Division

                                                          This laboratory is accredited by the NVLAP LAB CODE
                                                          200572-0, U.S.A. The tests reported herein have been
                                                          performed in accordance with its terms of accreditation.
                                                          *As for the range of Accreditation in NVLAP, you may
                                                          refer to the WEB address,
                                                          http://japan.ul.com/resources/emc_accredited/

      NVLAP LAB CODE: 200572-0

   The testing in which "Non-accreditation" is displayed is outside the accreditation scopes in UL Japan.
   There is no testing item of "Non-accreditation".

UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone        : +81 596 24 8999
Facsimile        : +81 596 24 8124                                                                          13-EM-F0429


                                                                           Test report No.   : 12584793H-R1
                                                                           Page              : 2 of 20
                                                                           Issued date       : November 21, 2018
                                                                           FCC ID            : CWTWB1G0169




                                   REVISION HISTORY
                                Original Test Report No.: 12584793H

Revision      Test report No.     Date                Page      Contents
                                                      revised
-             12584793H           November 19,        -         -
(Original)                        2018
1             12584793H-R1        November 21,        P. 13     Correction of Radiated Emission data
                                  2018




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone        : +81 596 24 8999
Facsimile        : +81 596 24 8124


                                                                                                       Test report No.        : 12584793H-R1
                                                                                                       Page                   : 3 of 20
                                                                                                       Issued date            : November 21, 2018
                                                                                                       FCC ID                 : CWTWB1G0169



CONTENTS                                                                                                                                  PAGE

SECTION 1: Customer information ꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏ 4
SECTION 2: Equipment under test (E.U.T.) ꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏ 4
SECTION 3: Test specification, procedures & resultsꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏ 5
SECTION 4: Operation of E.U.T. during testing ꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏ 8
SECTION 5: Radiated emission (Electric Field Strength of Fundamental and Spurious Emission) 9
SECTION 6: Automatically deactivate ꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏ 11
SECTION 7: -20 dB and 99 % Occupied Bandwidth ꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏ 11
APPENDIX 1: Test data ꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏ 12
    Automatically deactivate................................................................................................................... 12
    Radiated Emission (Electric Field Strength of Fundamental and Spurious Emission) ..................... 13
    -20dB and 99% Occupied Bandwidth ............................................................................................... 15
APPENDIX 2: Test Instruments ꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏ 16
APPENDIX 3: Photographs of test setup ꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏ 17
    Radiated emission ............................................................................................................................. 18
    Worst case position ........................................................................................................................... 19




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone        : +81 596 24 8999
Facsimile        : +81 596 24 8124


                                                                                  Test report No.   : 12584793H-R1
                                                                                  Page              : 4 of 20
                                                                                  Issued date       : November 21, 2018
                                                                                  FCC ID            : CWTWB1G0169



SECTION 1: Customer information
Company Name                            :     ALPS ELECTRIC CO., LTD.
Address                                 :     6-3-36, Nakazato, Furukawa, Osaki-city, Miyagi-pref., 989-6181, Japan
Telephone Number                        :     +81-229-23-5111
Facsimile Number                        :     +81-229-22-6290
Contact Person                          :     Yasuhiro Yabe



SECTION 2: Equipment under test (E.U.T.)
2.1      Identification of E.U.T.

Type of Equipment                       :     Passive Entry System
Model No.                               :     TWB1G0169
Serial No.                              :     Refer to Section 4, Clause 4.2
Rating                                  :     DC 3.0 V (CR2025 x 1)
Receipt Date of Sample                  :     November 6, 2018
Country of Manufacture                  :     China
Condition of EUT                        :     Engineering prototype
                                              (Not for Sale: This sample is equivalent to mass-produced items.)
Modification of EUT                     :     No Modification by the test lab


2.2    Product description

Model No: TWB1G0169 (referred to as the EUT in this report) is the Passive Entry System.

Radio Specification
[Transmitter]
 Radio Type                             :     Transmitter
 Operating Channel                      :     433.92 MHz
 Modulation                             :     FSK
 Method of Frequency Generation         :     Crystal
 Antenna Type                           :     PCB Pattern Antenna
 Clock frequency (Maximum)              :     433.935 MHz

[Receiver] *1)
 Radio Type                             :     Receiver
 Frequency of Operation                 :     125 kHz
 Antenna Type                           :     Loop Coil and Bar Antenna

*1) The test of receiver part was performed separately from this test report, and the conformability is confirmed.




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone        : +81 596 24 8999
Facsimile        : +81 596 24 8124


                                                                                             Test report No.     : 12584793H-R1
                                                                                             Page                : 5 of 20
                                                                                             Issued date         : November 21, 2018
                                                                                             FCC ID              : CWTWB1G0169



 SECTION 3: Test specification, procedures & results

 3.1     Test Specification

 Test Specification           :      FCC Part 15 Subpart C
                                     FCC Part 15 final revised on March 12, 2018 and effective April 11, 2018

 Title                        :      FCC 47CFR Part15 Radio Frequency Device Subpart C Intentional Radiators
                                     Section 15.231 Periodic operation in the band 40.66-40.70 MHz and above 70 MHz.


 3.2     Procedures and results

Item                         Test Procedure          Specification                   Worst margin              Results      Remarks
                             FCC: ANSI C63.10:2013 FCC: Section 15.207
                             6 Standard test methods
Conducted emission                                                                   N/A *1)                   N/A          -
                             IC: RSS-Gen 8.8             IC: RSS-Gen 8.8


                             FCC: ANSI C63.10:2013 FCC: Section
                             6 Standard test methods 15.231(a)(1)
Automatically Deactivate                                                             N/A                       Complied     Radiated
                             IC: -                       IC: RSS-210 A1.1
                             FCC: ANSI C63.10:2013 FCC: Section 15.231(b)            5.3 dB
Electric Field Strength      6 Standard test methods                                 433.920 MHz
                                                                                                               Complied     Radiated
of Fundamental Emission                                                              Horizontal,
                             IC: RSS-Gen 6.12            IC: RSS-210 A1.2            PK with Duty factor
                             FCC: ANSI C63.10:2013 FCC: Section 15.205
                                                                                     7.5 dB
                             6 Standard test methods   Section 15.209
Electric Field Strength                                                              4339.200 MHz
                                                       Section 15.231(b)                                       Complied     Radiated
of Spurious Emission                                                                 Horizontal / Vertical
                             IC: RSS-Gen 6.13        IC: RSS-210 A1.2, 4.4
                                                                                     PK with Duty factor
                                                         RSS-Gen 8.9
                             FCC: ANSI C63.10:2013 FCC: Section 15.231(c)
                             6 Standard test methods
-20dB Bandwidth                                                                      N/A                       Complied     Radiated
                             IC: -                       IC: Reference data

Note: UL Japan, Inc.’s EMI Work Procedures No. 13-EM-W0420 and 13-EM-W0422.
*1) The test is not applicable since the EUT does not have AC Mains.
Symbols:
 Complied            The data of this test item has enough margin, more than the measurement uncertainty.
 Complied#           The data of this test item meets the limits unless the measurement uncertainty is taken into consideration.

 FCC Part 15.31 (e)
 This test was performed with the New Battery (DC 3.0 V) during the tests. Therefore, the EUT complies with the
 requirement.

 FCC Part 15.203 Antenna requirement
 It is impossible for end users to replace the antenna, because the antenna is mounted inside of the EUT. Therefore, the
 equipment complies with the antenna requirement of Section 15.203.




 UL Japan, Inc.
 Ise EMC Lab.
 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
 Telephone        : +81 596 24 8999
 Facsimile        : +81 596 24 8124


                                                                                   Test report No.    : 12584793H-R1
                                                                                   Page               : 6 of 20
                                                                                   Issued date        : November 21, 2018
                                                                                   FCC ID             : CWTWB1G0169



3.3        Addition to standard

  Item                     Test Procedure      Specification        Worst margin      Results         Remarks
  99 % Occupied
                           IC: RSS-Gen 6.7     IC: RSS-210 A1.3     N/A               Complied        Radiated
  Bandwidth
Other than above, no addition, exclusion nor deviation has been made from the standard.


3.4        Uncertainty

                                               Radiated emission (Below 1 GHz)
        Polarity                   (3 m*)(+/-)                                 (10 m*)(+/-)
                    30 MHz to 200 MHz    200 MHz to 1000 MHz    30 MHz to 200 MHz    200 MHz to 1000 MHz
       Horizontal        4.8 dB                5.2 dB                  4.8 dB               5.0 dB
        Vertical         5.0 dB                6.3 dB                  4.9 dB               5.0 dB

                                             Radiated emission (Above 1 GHz)
                 (3 m*)(+/-)                                     (1 m*)(+/-)                       (10 m*)(+/-)
    1 GHz to 6 GHz      6 GHz to 18 GHz        10 GHz to 26.5 GHz      26.5 GHz to 40 GHz        1 GHz to 18 GHz
         5.2 dB              5.5 dB                   5.9 dB                 5.9 dB                   5.5 dB
* Measurement distance

      Automatically Deactivate
      0.10 %

      Bandwidth
      0.96 %




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone        : +81 596 24 8999
Facsimile        : +81 596 24 8124


                                                                                                Test report No.       : 12584793H-R1
                                                                                                Page                  : 7 of 20
                                                                                                Issued date           : November 21, 2018
                                                                                                FCC ID                : CWTWB1G0169



3.5         Test Location

UL Japan, Inc. Ise EM C Lab.
4383-326 Asama-cho, Ise-shi, M ie-ken 516-0021 JAPAN
Telephone: +81 596 24 8999, Facsimile: +81 596 24 8124
NVLAP Lab. code: 200572-0 / FCC Test Firm Registration Number: 199967
                                                                                                                              M aximum
                       IC Registration   Width x Depth x        Size of reference ground plane (m) /
Test site                                                                                               Other rooms           measurement
                       Number            Height (m)             horizontal conducting plane
                                                                                                                              distance
No.1 semi-anechoic                                                                                        No.1 Power source
                         2973C-1           19.2 x 11.2 x 7.7     7.0 x 6.0                                                    10 m
chamber                                                                                                   room
No.2 semi-anechoic
                         2973C-2           7.5 x 5.8 x 5.2       4.0 x 4.0                                -                   3m
chamber
No.3 semi-anechoic                                                                                        No.3 Preparation
                         2973C-3           12.0 x 8.5 x 5.9      6.8 x 5.75                                                   3m
chamber                                                                                                   room
No.3 shielded room       -                 4.0 x 6.0 x 2.7       N/A                                      -                   -
No.4 semi-anechoic                                                                                        No.4 Preparation
                         2973C-4           12.0 x 8.5 x 5.9      6.8 x 5.75                                                   3m
chamber                                                                                                   room
No.4 shielded room       -                 4.0 x 6.0 x 2.7       N/A                                      -                   -
No.5 semi-anechoic
                         -                 6.0 x 6.0 x 3.9       6.0 x 6.0                                -                   -
chamber
No.6 shielded room       -                 4.0 x 4.5 x 2.7       4.0 x 4.5                                -                   -
No.6 measurement
                         -                 4.75 x 5.4 x 3.0      4.75 x 4.15                              -                   -
room
No.7 shielded room       -                 4.7 x 7.5 x 2.7       4.7 x 7.5                                -                   -
No.8 measurement
                         -                 3.1 x 5.0 x 2.7       N/A                                      -                   -
room
No.9 measurement
                         -                 8.8 x 4.6 x 2.8       2.4 x 2.4                                -                   -
room
No.11 measurement
                         -                 6.2 x 4.7 x 3.0       4.8 x 4.6                                -                   -
room
* Size of vertical conducting plane (for Conducted Emission test) : 2.0 m x 2.0 m for No.1, No.2, No.3, and No.4 semi-
anechoic chambers and No.3 and No.4 shielded rooms.



3.6     Test data, Test instruments, and Test set up.

Refer to APPENDIX.




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone        : +81 596 24 8999
Facsimile        : +81 596 24 8124


                                                                                 Test report No.     : 12584793H-R1
                                                                                 Page                : 8 of 20
                                                                                 Issued date         : November 21, 2018
                                                                                 FCC ID              : CWTWB1G0169



SECTION 4: Operation of E.U.T. during testing
4.1      Operating Modes

Test Item                                               Mode
Automatically Deactivate                                Normal use mode *
Electric Field Strength of Fundamental Emission         Transmitting mode (Tx)
Electric Field Strength of Spurious Emission
-20dB & 99% Occupied Bandwidth
The system was configured in typical fashion (as a customer would normally use it) for testing.
* Normal use mode has the following two operations;
   - Transmission by a button-pressed operation
   - Smart operation to transmit after LF signal is received
  The test was performed by a button-pressed operation as representative, since they are completely identical in
  RF characteristics.


4.2 Configuration and peripherals



                                                           A




                                   * Test data was taken under worse case conditions.

Description of EUT
 No. Item                         Model number          Serial number      Manufacturer                       Remarks
 A    Passive Entry System        TWB1G0169             464-2 *1)          Alps Electric Co., Ltd.            EUT
                                                        464-1 *2)
*1) Used for Transmitting mode
*2) Used for Normal use mode




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone        : +81 596 24 8999
Facsimile        : +81 596 24 8124


                                                                                  Test report No.    : 12584793H-R1
                                                                                  Page               : 9 of 20
                                                                                  Issued date        : November 21, 2018
                                                                                  FCC ID             : CWTWB1G0169



SECTION 5:          Radiated emission (Electric Field Strength of Fundamental and Spurious
Emission)
Test Procedure and conditions

[For below 30 MHz]
The noise level was checked by moving a search-coil (Loop Antenna) close to the EUT.

[For 30 MHz to 1 GHz]
EUT was placed on a urethane platform of nominal size, 0.5 m by 1.0 m, raised 0.8 m above the conducting ground plane.
The Radiated Electric Field Strength has been measured in a Semi Anechoic Chamber with a ground plane.

[For above 1 GHz]
EUT was placed on a urethane platform of nominal size, 0.5 m by 0.5 m, raised 1.5 m above the conducting ground plane.
The Radiated Electric Field Strength has been measured in a Semi Anechoic Chamber with absorbent materials lined on
a ground plane.

The measuring antenna height was varied between 1 and 4 m and EUT was rotated a full revolution in order to obtain the
maximum value of the electric field strength.
The measurements were performed for both vertical and horizontal antenna polarization.
The radiated emission measurements were made with the following detector function of the test receiver / spectrum analyzer.

Test Antennas are used as below;
   Frequency            Below 30 MHz              30 MHz to 200 MHz      200 MHz to 1 GHz           Above 1 GHz
   Antenna Type         Loop                      Biconical              Logperiodic                Horn

                    From 9 kHz          From             From            From            From            Above 1 GHz
                   to 90 kHz and       90 kHz          150 kHz         490 kHz          30 MHz
                   From 110 kHz      to 110 kHz       to 490 kHz      to 30 MHz        to 1 GHz
                     to 150 kHz
  Detector              Peak            Peak             Peak           Peak          Peak and      Peak and
  Type                                                                               Peak with      Peak with Duty factor
                                                                                     Duty factor
  IF Bandwidth        200 Hz           200 Hz          9.1 kHz         9.1 kHz        120 kHz       PK: S/A: RBW 1 MHz,
                                                                                                           VBW: 3 MHz




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone        : +81 596 24 8999
Facsimile        : +81 596 24 8124


                                                                                    Test report No.     : 12584793H-R1
                                                                                    Page                : 10 of 20
                                                                                    Issued date         : November 21, 2018
                                                                                    FCC ID              : CWTWB1G0169



[Test Setup]

Below 1 GHz
                                                               Test Distance: 3 m




1 GHz - 10 GHz
                                                               Distance Factor: 20 x log (4.0 m / 3.0 m) = 2.5 dB
                                                               * Test Distance: (3 + Test Volume /2) - r = 4.0 m

                                                               Test Volume : 2.0 m
                                                               (Test Volume has been calibrated based on CISPR 16-1-4.)
                                                                r = 0.0 m

                                                               * The test was performed with r = 0.0 m since EUT is small
                                                               and it was the rather conservative condition.




- The carrier level (or, noise levels) was (or were) measured at each position of all three axes X, Y and Z, and the
position that has the maximum noise was determined.
Noise levels of all the frequencies were measured at the position.

This EUT has two modes which mechanical key is inserted or not. The worst case was confirmed with and without
mechanical key, as a result, the test without mechanical key was the worst case. Therefore the test without mechanical
key was performed only.

*The result is rounded off to the second decimal place, so some differences might be observed.


Measurement range          : 9 kHz – 4.4 GHz
Test data                  : APPENDIX
Test result                : Pass




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone        : +81 596 24 8999
Facsimile        : +81 596 24 8124


                                                                               Test report No.     : 12584793H-R1
                                                                               Page                : 11 of 20
                                                                               Issued date         : November 21, 2018
                                                                               FCC ID              : CWTWB1G0169



SECTION 6: Automatically deactivate

Test Procedure

The measurement was performed with Electric field strength using a spectrum analyzer.

Test data                                : APPENDIX
Test result                              : Pass



SECTION 7: -20 dB and 99 % Occupied Bandwidth
Test Procedure

The test was measured with a spectrum analyzer using a test fixture.

Test               Span                       RBW        VBW           Sweep   Detector    Trace        Instrument used
20 dB Bandwidth     500 kHz                   1 kHz      3 kHz         Auto    Peak        Max Hold     Spectrum Analyzer
99 % Occupied       Enough width to display   1 to 5 %   Three times   Auto    Peak        Max Hold     Spectrum Analyzer
Bandwidth           emission skirts           of OBW     of RBW
Peak hold was applied as Worst-case measurement.

Test data                     : APPENDIX
Test result                   : Pass




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone        : +81 596 24 8999
Facsimile        : +81 596 24 8124


                                                                               Test report No.   : 12584793H-R1
                                                                               Page              : 12 of 20
                                                                               Issued date       : November 21, 2018
                                                                               FCC ID            : CWTWB1G0169



APPENDIX 1: Test data

                                             Automatically deactivate
                     Report No.                 12584793H
                     Test place                 Ise EMC Lab. No.4 Semi Anechoic Chamber
                     Date                       11/13/2018
                     Temperature/ Humidity      21 deg. C / 47 % RH
                     Engineer                   Yuta Moriya
                     Mode                       Normal use mode

                              Time of                      Limit                    Result
                            Transmitting
                                [sec]                      [sec]
                               0.7375                      5.00                      Pass




* The EUT transmits UHF when LF signal is received from a car or a button on the EUT is pressed. In both cases, the
UHF transmission is stopped within 5 seconds. So the test was performed by a button-pressed operation as the worst case.
Please refer to the “Theory of Operation” for details.




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone        : +81 596 24 8999
Facsimile        : +81 596 24 8124


                                                                                                                          Test report No.             : 12584793H-R1
                                                                                                                          Page                        : 13 of 20
                                                                                                                          Issued date                 : November 21, 2018
                                                                                                                          FCC ID                      : CWTWB1G0169



      Radiated Emission (Electric Field Strength of Fundamental and Spurious Emission)
                Report No.                               12584793H
                Test place                               Ise EMC Lab. No.4 Semi Anechoic Chamber
                Date                                     11/13/2018
                Temperature/ Humidity                    21 deg. C / 47 % RH
                Engineer                                 Yuta Moriya
                Mode                                     Transmitting mode (Tx 433.92 MHz)

       PK
         Frequency      Detector        Reading           Ant      Loss     Gain      Duty              Result           Limit       Margin                     Remark
                                        [dBuV]           Factor                      Factor        [dBuV/m]                              [dB]            Inside or Outside
            [MHz]                    Hor       Ver       [dB/m]    [dB]     [dB]      [dB]        Hor        Ver        [dBuV/m]   Hor          Ver     of Restricted Bands
             433.920 PK                80.3       79.6     16.4     10.8      32.0            -    75.5          74.8     100.8     25.3         26.0 Carrier
             867.840 PK                28.0       28.0     22.0     13.0      31.4            -    31.6          31.6      80.8     49.2         49.2 Outside
            1301.760 PK                49.0       47.7     25.4       4.5     33.1            -    45.8          44.5      73.9     28.1         29.4 Inside
            1735.680 PK                46.1       47.4     25.3       4.8     32.0            -    44.2          45.5      80.8     36.6         35.3 Outside
            2169.600 PK                50.1       50.7     27.5       5.0     31.4            -    51.2          51.8      80.8     29.6         29.0 Outside
            2603.520 PK                42.7       43.7     28.2       5.3     31.2            -    45.0          46.0      80.8     35.8         34.8 Outside
            3037.440 PK                42.3       41.3     28.5       5.5     31.1            -    45.2          44.2      80.8     35.6         36.6 Outside
            3471.360 PK                40.8       40.4     29.0       5.7     30.9            -    44.6          44.2      80.8     36.2         36.6 Outside
            3905.280 PK                41.2       40.2     29.7       5.9     30.7            -    46.1          45.1      73.9     27.8         28.8 Inside
            4339.200 PK                40.6       40.6     30.4       6.1     30.7            -    46.4          46.4      73.9     27.5         27.5 Inside
       Result = Reading + Ant Factor + Loss (Cable+Attenuator+Filter) - Gain(Amprifier)



       PK with Duty factor
         Frequency      Detector        Reading           Ant      Loss     Gain      Duty              Result           Limit       Margin                     Remark
                                        [dBuV]           Factor                      Factor        [dBuV/m]                              [dB]
            [MHz]                    Hor       Ver       [dB/m]    [dB]     [dB]      [dB]        Hor        Ver        [dBuV/m]   Hor          Ver
             433.920 PK                80.3       79.6     16.4     10.8      32.0        0.0      75.5          74.8      80.8      5.3          6.0 Carrier
             867.840 PK                28.0       28.0     22.0     13.0      31.4        0.0      31.6          31.6      60.8     29.2         29.2 Outside
            1301.760 PK                49.0       47.7     25.4       4.5     33.1        0.0      45.8          44.5      53.9      8.1          9.4 Inside
            1735.680 PK                46.1       47.4     25.3       4.8     32.0        0.0      44.2          45.5      60.8     16.6         15.3 Outside
            2169.600 PK                50.1       50.7     27.5       5.0     31.4        0.0      51.2          51.8      60.8      9.6          9.0 Outside
            2603.520 PK                42.7       43.7     28.2       5.3     31.2        0.0      45.0          46.0      60.8     15.8         14.8 Outside
            3037.440 PK                42.3       41.3     28.5       5.5     31.1        0.0      45.2          44.2      60.8     15.6         16.6 Outside
            3471.360 PK                40.8       40.4     29.0       5.7     30.9        0.0      44.6          44.2      60.8     16.2         16.6 Outside
            3905.280 PK                41.2       40.2     29.7       5.9     30.7        0.0      46.1          45.1      53.9      7.8          8.8 Inside
            4339.200 PK                40.6       40.6     30.4       6.1     30.7        0.0      46.4          46.4      53.9      7.5          7.5 Inside
       Result = Reading + Ant Factor + Loss (Cable+Attenuator+Filter) - Gain(Amprifier) + Duty factor




Sample calculation:
Result of PK = Reading + Ant Factor + Loss (Cable + Attenuator +Filter) - Gain (Amplifier)
Result of PK with Duty factor = Reading + Ant Factor + Loss (Cable + Attenuator + Filter) - Gain (Amplifier) + Duty
factor

For above 1GHz : Distance Factor: 20 x log (4.0 m/3.0 m) = 2.5 dB
*Other frequency noises omitted in this report were not seen or had enough margin (more than 20dB).

Since the peak emission result satisfied the average limit, duty factor was omitted.
Although Duty of this product was 100% or less, the result of AV (PK with Duty factor) was calculated by applying
Duty 100% as worst.




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone        : +81 596 24 8999
Facsimile        : +81 596 24 8124


                                                                                                             Test report No.      : 12584793H-R1
                                                                                                             Page                 : 14 of 20
                                                                                                             Issued date          : November 21, 2018
                                                                                                             FCC ID               : CWTWB1G0169



                                                                Radiated Spurious Emission
                                                                  (Plot data, Worst case)

             Report No.                                        12584793H
             Test place                                        Ise EMC Lab. No.4 Semi Anechoic Chamber
             Date                                              11/13/2018
             Temperature/ Humidity                             21 deg. C / 47 % RH
             Engineer                                          Yuta Moriya
             Mode                                              Transmitting mode (Tx 433.92 MHz)



                                                                              Horizontal
                                              90
                                              80
                    Field strength [dBuV/m]




                                              70
                                              60
                                              50
                                              40
                                              30
                                              20
                                              10
                                               0
                                                   10                   100                          1000                       10000
                                                                                  Frequency [MHz]

                                                        Peak     Peak with duty factor       Average Limit      Average Limit



                                                                                 Vertical
                                              90
                                              80
                    Field strength [dBuV/m]




                                              70
                                              60
                                              50
                                              40
                                              30
                                              20
                                              10
                                              0
                                                   10                   100                          1000                       10000
                                                                                  Frequency [MHz]

                                                        Peak     Peak with duty factor       Average Limit      Average Limit



           *These plots data contains sufficient number to show the trend of characteristic features for EUT.




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone        : +81 596 24 8999
Facsimile        : +81 596 24 8124


                                                                                Test report No.   : 12584793H-R1
                                                                                Page              : 15 of 20
                                                                                Issued date       : November 21, 2018
                                                                                FCC ID            : CWTWB1G0169



                                     -20dB and 99% Occupied Bandwidth
             Report No.                 12584793H
             Test place                 Ise EMC Lab. No.4 Semi Anechoic Chamber
             Date                       11/13/2018
             Temperature/ Humidity      21 deg. C / 47 % RH
             Engineer                   Yuta Moriya
             Mode                       Transmitting mode (Tx 433.92 MHz)

                       Bandwidth Limit : Fundamental Frequency          433.92 MHz x 0.25% = 1084.800   kHz
                           * The above limit was calculated from more stringent nominal frequency.

                            -20dB Bandwidth           Bandwidth Limit           Result
                                 [kHz]                     [kHz]
                               113.8100                  1084.800                 Pass

                        99% Occupied Bandwidth        Bandwidth Limit           Result
                                [kHz]                      [kHz]
                              116.9252                   1084.800                 Pass




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone        : +81 596 24 8999
Facsimile        : +81 596 24 8124


                                                                                  Test report No.        : 12584793H-R1
                                                                                  Page                   : 16 of 20
                                                                                  Issued date            : November 21, 2018
                                                                                  FCC ID                 : CWTWB1G0169



APPENDIX 2: Test Instruments
Test Instruments
 Test   LIMS       Description         Manufacturer   Model           Serial               Last                Calibration     Cal
 item   ID                                                                                 Calibration         Due Date        Int
                                                                                           Date
 RE     148898     Attenuator          KEYSIGHT       8491A           MY52462282           10/3/2018           10/31/2019      12
 RE     142227     Measure             KOMELON        KMC-36          -                     -                  -               -
 RE     141397     Coaxial Cable       UL Japan       -               -                    6/13/2018           6/30/2019       12
 RE     141545     DIGITAL             HIOKI          3805            51201148             1/9/2018            1/31/2019       12
                   HiTESTER
 RE     141951     EMI Test Receiver   Rohde &        ESR26           101408               1/30/2018           1/31/2019       12
                                       Schwarz
 RE     141152     EMI measurement     TSJ            TEPTO-DV        -                    -                   -               -
                   program
 RE     141267     Logperiodic         Schwarzbeck    VUSLP9111B      911B-192             6/1/2018            6/30/2019       12
                   Antenna(200-
                   1000MHz)
 RE     141583     Pre Amplifier       SONOMA         11/5/1900       260833               2/27/2018           2/28/2019       12
                                       INSTRUMENT
 RE     142011     AC4_Semi            TDK            Semi Anechoic   DA-10005             6/28/2018           6/30/2020       24
                   Anechoic                           Chamber 3m
                   Chamber(NSA)
 RE     141562     Thermo-             CUSTOM         CTH-180         1501                 1/24/2018           1/31/2019       12
                   Hygrometer
 RE     142017     AC4_Semi            TDK            Semi Anechoic   DA-10005             4/7/2018            4/30/2019       12
                   Anechoic                           Chamber 3m
                   Chamber(SVSWR)
 RE     141508     Horn Antenna 1-     Schwarzbeck    BBHA9120D       9120D-557            6/8/2018            6/30/2019       12
                   18GHz
 RE     141581     MicroWave           AGILENT        83017A          650                  10/4/2018           10/31/2019      12
                   System Amplifier
 RE     141412     Microwave Cable     Junkosha       MWX221          1305S002R(1m) /      6/14/2018           6/30/2019       12
                                                                      1405S146(5m)
 RE     141900     Spectrum Analyzer   AGILENT        E4440A          MY46185823           11/16/2017          11/30/2018      12
 RE     141425     Biconical Antenna   Schwarzbeck    BBA9106         1302                 6/1/2018            6/30/2019       12
 RE     142645     Loop Antenna        UL Japan       -               -                    -                   -               -

*Hyphens for Calibration Due Date and Cal Int (month) are instruments that Calibration is not required (e.g.
software), or instruments checked in advance before use.

The expiration date of the calibration is the end of the expired month.
All equipment is calibrated with valid calibrations. Each measurement data is traceable to the national or
international standards.

As for some calibrations performed after the tested dates, those test equipment have been controlled by means of
an unbroken chains of calibrations.

Test item:
RE: Radiated emission, 99 % Occupied Bandwidth, -20 dB bandwidth, and Automatically deactivate tests




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone        : +81 596 24 8999
Facsimile        : +81 596 24 8124



Document Created: 2019-03-26 21:23:25
Document Modified: 2019-03-26 21:23:25

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC