RF Exposure Report

FCC ID: COFWMSGSM42

RF Exposure Info

Download: PDF
FCCID_3311920

                                                           RF Exposure Report

                       Report No.: SA161019E02

                            FCC ID: COFWMSGSM42

                       Test Model: WM-SG-SM-42

                 Received Date: Oct. 19, 2016

                         Test Date: Jan. 11, 2017

                     Issued Date: Feb. 10, 2017


                         Applicant: UNIVERSAL GLOBAL SCIENTIFIC INDUSTRIAL CO., LTD.

                          Address: 141, Lane 351, Sec. 1, Taiping Road., Tsaotuen, Nantou 54261, Taiwan



                        Issued By: Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch
                                   Hsin Chu Laboratory
                    Lab Address: E-2, No.1, Li Hsin 1st Road, Hsinchu Science Park, Hsinchu City 300,
                                 Taiwan R.O.C.




This report is for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted
only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this
report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product
unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you
provided to us. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence, provided,
however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time
shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Unless specific
mention, the uncertainty of measurement has been explicitly taken into account to declare the compliance or non-compliance to the specification. The report
must not be used by the client to claim product certification, approval, or endorsement by any government agencies.

Report No.: SA161019E02                                              Page No. 1 / 6                                             Report Format Version: 6.1.1


                                                                   Table of Contents
Release Control Record .................................................................................................................................. 3
1         Certificate of Conformity ...................................................................................................................... 4
2         RF Exposure .......................................................................................................................................... 5
    2.1      Limits For Maximum Permissible Exposure (MPE) ............................................................................. 5
    2.2      MPE Calculation Formula ................................................................................................................... 5
    2.3      Classification ....................................................................................................................................... 5
    2.4      Calculation Result of Maximum Conducted Power ............................................................................. 6




Report No.: SA161019E02                                              Page No. 2 / 6                                              Report Format Version: 6.1.1


                                          Release Control Record


Issue No.             Description                                         Date Issued
SA161019E02           Original release.                                   Feb. 10, 2017




Report No.: SA161019E02                      Page No. 3 / 6        Report Format Version: 6.1.1


1    Certificate of Conformity


            Product: LPWAN module

              Brand: USI

        Test Model: WM-SG-SM-42

    Sample Status: ENGINEERING SAMPLE

          Applicant: UNIVERSAL GLOBAL SCIENTIFIC INDUSTRIAL CO., LTD.

          Test Date: Jan. 11, 2017

         Standards: FCC Part 2 (Section 2.1091)

                          KDB 447498 D01 General RF Exposure Guidance v06
                          IEEE C95.1-1992



The above equipment has been tested by Bureau Veritas Consumer Products Services (H.K.) Ltd.,
Taoyuan Branch, and found compliance with the requirement of the above standards. The test record, data
evaluation & Equipment Under Test (EUT) configurations represented herein are true and accurate accounts
of the measurements of the sample’s EMC characteristics under the conditions specified in this report.




      Prepared by :                                             ,   Date:       Feb. 10, 2017
                                Claire Kuan / Specialist




     Approved by :                                              ,   Date:       Feb. 10, 2017
                                 May Chen / Manager




Report No.: SA161019E02                        Page No. 4 / 6                        Report Format Version: 6.1.1


2      RF Exposure

2.1      Limits For Maximum Permissible Exposure (MPE)

    Frequency Range            Electric Field     Magnetic Field       Power Density      Average Time
                                                                                2
         (MHz)                Strength (V/m)      Strength (A/m)         (mW/cm )           (minutes)
                               Limits For General Population / Uncontrolled Exposure
        300-1500                    …                    …                F/1500                 30
      1500-100,000                  …                    …                  1.0                  30

F = Frequency in MHz



2.2      MPE Calculation Formula

                          2
Pd = (Pout*G) / (4*pi*r )
where
                                   2
Pd = power density in mW/cm
Pout = output power to antenna in mW
G = gain of antenna in linear scale
Pi = 3.1416
R = distance between observation point and center of the radiator in cm



2.3      Classification

      The antenna of this product, under normal use condition, is at least 20cm away from the body of the user.
      So, this device is classified as Mobile Device.




Report No.: SA161019E02                            Page No. 5 / 6                       Report Format Version: 6.1.1


2.4     Calculation Result of Maximum Conducted Power

For Hybrid Mode (125kHz Bandwidth, 64 channels):

  Frequency      Max Power    Max Power
                                           Antenna Gain     Distance   Power Density      Limit
     Band           Avg.         Avg.                                           2             2
                                               (dBi)          (cm)       (mW/cm )        (W/m )
    (MHz)          (dBm)        (mW)
902.3~914.9          19.50      89.125          2.3           20         0.03011         0.60153

NOTE:    1. Power Density Limit = F/1500
         2. This power include tune-up tolerance range that specified in WM-SG-SM-42 Tune Up power
            table.


For Hybrid Mode (500kHz Bandwidth, 8 channels):
  Frequency      Max Power    Max Power
                                           Antenna Gain     Distance   Power Density      Limit
     Band           Avg.         Avg.                                           2             2
                                               (dBi)          (cm)       (mW/cm )        (W/m )
    (MHz)          (dBm)        (mW)
  903~914.2          19.50      89.125          2.3           20         0.03011          0.602

NOTE:    1. Power Density Limit = F/1500
         2. This power include tune-up tolerance range that specified in WM-SG-SM-42 Tune Up power
            table.


For DTS Mode (500kHz Bandwidth, 8 channels):
  Frequency      Max Power    Max Power
                                           Antenna Gain     Distance   Power Density      Limit
     Band           Avg.         Avg.                                           2             2
                                               (dBi)          (cm)       (mW/cm )        (W/m )
    (MHz)          (dBm)        (mW)
  903~914.2          19.50      89.125          2.3           20         0.03011          0.602

NOTE:    1. Power Density Limit = F/1500
         2. This power include tune-up tolerance range that specified in WM-SG-SM-42 Tune Up power
            table.


--- END ---




Report No.: SA161019E02                    Page No. 6 / 6                      Report Format Version: 6.1.1



Document Created: 2017-12-25 12:56:21
Document Modified: 2017-12-25 12:56:21

© 2025 FCC.report