User Manual

FCC ID: COF-WPSGTAG01

Users Manual

Download: PDF

LoRa Tag User Manual

Product Name: LoRa Tag
Model No.: WP-SG-TAG-01




Version: 1.0


Universal Global Scientific Industrial Co., Ltd.            Doc No.                              Rev            1.0

Document release by WSS2/WP1/SW                             Date.         2018/12/04             Page           2

Description     Lora Tag User Manual


                                       Amendment Records

    Item:     Date:      Revision:    Page:                     Change Description:               Changed by:

      1     11/28/2018       1.0        All   Initial release                                            Andy




    The content of this document is to be treaded as strictly confidential and is not to be disclosed,
    reproduced or used, except as authorized in writing by Universal Scientific Industrial Co.,Ltd.
    Copyright(c) 2016 Universal Scientific Industrial Co.,Ltd.


Universal Global Scientific Industrial Co., Ltd.                             Doc No.                                           Rev               1.0

Document release by WSS2/WP1/SW                                              Date.            2018/12/04                       Page               3

Description           Lora Tag User Manual



Contents
Contents .............................................................................................................................................. 3
1. Tag Unit Overview ...................................................................................................................... 4
2. How to use the Tag ..................................................................................................................... 5
3. Operation Frequency .................................................................................................................. 6
4. Operation Mode .......................................................................................................................... 7
    4.1 POWER UP Mode ................................................................................................................. 7
    4.2 STORAGE Mode ................................................................................................................... 8
    4.3 UNBOX Mode ........................................................................................................................ 8
    4.4 EVENT Mode ......................................................................................................................... 8
    4.5 STATUS Mode ....................................................................................................................... 9




     The content of this document is to be treaded as strictly confidential and is not to be disclosed,
     reproduced or used, except as authorized in writing by Universal Scientific Industrial Co.,Ltd.
     Copyright(c) 2016 Universal Scientific Industrial Co.,Ltd.


Universal Global Scientific Industrial Co., Ltd.              Doc No.                                Rev    1.0

Document release by WSS2/WP1/SW                               Date.       2018/12/04                 Page   4

Description         LoRa Tag User Manual




1. Tag Unit Overview
                                                                          Product Name: LoRa Tag
                                                                          Model No.: WP-SG-TAG-01
                1                                                         FCC ID: COF-WPSGTAG01



                                                          3




                                                                                4

            7
                                                                           6
        2
                              Imprint Battery                         5




1. Antenna
2. 2D code with serial number
3. S1 Trace
4. S2 Pads
5. Imprint Battery
6. PWR+ Pad (+3.3V)
7. PWR- Pad (GND)




The content of this document is to be treaded as strictly confidential and is not to be disclosed,
reproduced or used, except as authorized in writing by Universal Scientific Industrial Co.,Ltd.
Copyright(c) 2016 Universal Scientific Industrial Co.,Ltd.


Universal Global Scientific Industrial Co., Ltd.             Doc No.                                 Rev      1.0

Document release by WSS2/WP1/SW                              Date.       2018/12/04                  Page      5

Description       LoRa Tag User Manual




2. How to use the Tag
Scan the 2D barcode using mobile phone at first and a web page will pop up, then peel off the label
from the poster, you may get a coupon from the web page




  Lora tag is embeded or hidden in poster

                                                                                                     2D barcode label on tag




   Peel off the label on Lora tag then start to transmit signal to mobile phone to get a coupon or prize




The content of this document is to be treaded as strictly confidential and is not to be disclosed,
reproduced or used, except as authorized in writing by Universal Scientific Industrial Co.,Ltd.
Copyright(c) 2016 Universal Scientific Industrial Co.,Ltd.


Universal Global Scientific Industrial Co., Ltd.             Doc No.                                 Rev    1.0

Document release by WSS2/WP1/SW                              Date.       2018/12/04                  Page   6

Description       LoRa Tag User Manual




3. Operation Frequency
There are 64 channels for tag use, and the channel/frequency are showed as below table
and the bandwidth on each frequency is 125KHz.




64 Channels are provided for Hopping Mode (125kHz Bandwidth):
 Channel Freq. (MHz) Channel Freq. (MHz) Channel Freq. (MHz) Channel Freq. (MHz)
    0        902.3         16       905.5       32       908.7 48       911.9
    1        902.5         17       905.7       33       908.9 49       912.1
    2        902.7         18       905.9       34       909.1 50       912.3
    3        902.9         19       906.1       35       909.3 51       912.5
    4        903.1         20       906.3       36       909.5 52       912.7
    5        903.3         21       906.5       37       909.7 53       912.9
    6        903.5         22       906.7       38       909.9 54       913.1
    7        903.7         23       906.9       39       910.1 55       913.3
    8        903.9         24       907.1       40       910.3 56       913.5
    9        904.1         25       907.3       41       910.5 57       913.7
   10        904.3         26       907.5       42       910.7 58       913.9
   11        904.5         27       907.7       43       910.9 59       914.1
   12        904.7         28       907.9       44       911.1 60       914.3
   13        904.9         29       908.1       45       911.3 61       914.5
   14        905.1         30       908.3       46       911.5 62       914.7
   15        905.3         31       908.5       47       911.7 63       914.9




The content of this document is to be treaded as strictly confidential and is not to be disclosed,
reproduced or used, except as authorized in writing by Universal Scientific Industrial Co.,Ltd.
Copyright(c) 2016 Universal Scientific Industrial Co.,Ltd.


Universal Global Scientific Industrial Co., Ltd.             Doc No.                                 Rev      1.0

Document release by WSS2/WP1/SW                              Date.       2018/12/04                  Page      7

Description       LoRa Tag User Manual




4. Operation Mode
There are 5 operation modes below in the tag life cycle.



       POWER UP                   STORAGE                    UNBOX                   EVENT                  STATUS
         MODE                      MODE                      MODE                    MODE                    MODE




4.1 POWER UP Mode
Started when power on, and will stopped after 5 ALIVE packets sent.

Packet Duty Cycle:
1 packet per 5 seconds

Packet Example:
"datr":"SF7BW125","addr":44012345, "port":59,"data":02000001B318

Payload Format:
 Port: 59
 BYTE 1 (bit7:0): Major Version
 BYTE 2 (bit7:0): Minor Version
 BYTE 3 (bit7:0): Patch Version
 BYTE 4 (bit7:4): S2 State, 0: Low Level, 1: High Level (Triggered)
 BYTE 4 (bit3:0): S1 State, 0: Low Level, 1: High Level (Triggered)
 BYTE 5 (bit7:0): VCC voltage (+150 = Real VCC Voltage)
 BYTE 6 (bit7:0): Temperature




The content of this document is to be treaded as strictly confidential and is not to be disclosed,
reproduced or used, except as authorized in writing by Universal Scientific Industrial Co.,Ltd.
Copyright(c) 2016 Universal Scientific Industrial Co.,Ltd.


Universal Global Scientific Industrial Co., Ltd.             Doc No.                                 Rev    1.0

Document release by WSS2/WP1/SW                              Date.       2018/12/04                  Page   8

Description       LoRa Tag User Manual



4.2 STORAGE Mode
Started after 5 ALIVE packets sent in power up mode, and will stop when S1 or S2 be triggered.
No any TX & RX in the storage mode.



4.3 UNBOX Mode
Started when S1 be triggered and will move to EVENT mode after 1 hour.

Packet Duty Cycle:
1 packet per 20 seconds in the initial hour

Packet Example:
"datr":"SF7BW125",addr":44012345, "port":60,"data":B318

Payload format:
 Port: 60
 BYTE 1 (bit7:0): VCC voltage (+150 = Real VCC Voltage)
 BYTE 2 (bit7:0): Temperature



4.4 EVENT Mode
Started at the end of UNBOX mode until S2 be triggered.

Packet Duty Cycle:
1 packet per hour

Packet Example:
"datr":"SF7BW125",addr":44012345, "port":60,"data":B318

Payload format:
 Port: 60
 BYTE 1 (bit7:0): VCC voltage (+150 = Real VCC Voltage)
 BYTE 2 (bit7:0): Temperature


The content of this document is to be treaded as strictly confidential and is not to be disclosed,
reproduced or used, except as authorized in writing by Universal Scientific Industrial Co.,Ltd.
Copyright(c) 2016 Universal Scientific Industrial Co.,Ltd.


Universal Global Scientific Industrial Co., Ltd.             Doc No.                                 Rev    1.0

Document release by WSS2/WP1/SW                              Date.       2018/12/04                  Page   9

Description       LoRa Tag User Manual




4.5 STATUS Mode
Started when S2 be triggered until no battery.

Packet Duty Cycle:
1 packet per 1 minute

Packet Example:
"datr":"SF7BW125",addr":44012345, "port": 61,"data": 00000000B318

Payload format:
 Port: 61
 BYTE 1 (bit7:0): bit 31:24 of Frame Count
 BYTE 2 (bit7:0): bit 23:24 of Frame Count
 BYTE 3 (bit7:0): bit 15:8 of Frame Count
 BYTE 4 (bit7:0): bit 7:0 of Frame Count
 BYTE 5 (bit7:0):VCC voltage (+150 = Real VCC Voltage)
 BYTE 6 (bit7:0): Temperature




The content of this document is to be treaded as strictly confidential and is not to be disclosed,
reproduced or used, except as authorized in writing by Universal Scientific Industrial Co.,Ltd.
Copyright(c) 2016 Universal Scientific Industrial Co.,Ltd.


              Federal Communication Commission Interference Statement

This device complies with Part 15 of the FCC Rules. Operation is subject to the following
two conditions: (1) This device may not cause harmful interference, and (2) this device must
accept any interference received, including interference that may cause undesired operation.


This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a residential installation. This
equipment generates, uses and can radiate radio frequency energy and, if not installed and
used in accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and on, the user
is encouraged to try to correct the interference by one of the following measures:


- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that
  to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.


FCC Caution: Any changes or modifications not expressly approved by the party responsible
for compliance could void the user's authority to operate this equipment.


This transmitter must not be co-located or operating in conjunction with any other antenna or
transmitter.


Radiation Exposure Statement:
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled
environment. This equipment should be installed and operated with minimum distance 5mm
between the radiator & your body.



Document Created: 2018-12-26 10:43:49
Document Modified: 2018-12-26 10:43:49

© 2019 FCC.report
This site is not affiliated with or endorsed by the FCC