Test Report 1

FCC ID: CNFSPTM1

Test Report

Download: PDF
FCCID_3905295

Report Number: 68.950.18.0211.01




                                                            FCC/IC - TEST REPORT



Report Number                                    :     68.950.18.0211.01                                Date of Issue:                        June 21, 2018


 Model                                           :     SPTM1

 Product Type                                    :     Camera

 Applicant                                       :     GoPro, Inc.

 Address                                         :     3000 Clearview Way, San Mateo, CA 94402, USA

 Production Facility                             :     GoPro, Inc.

 Address                                         :     3000 Clearview Way, San Mateo, CA 94402, USA


Test Result                                      :      Positive                       Negative



Total pages including
Appendices                                       :     30




TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch is a subcontractor to TÜV SÜD Product Service GmbH according to the principles outlined in
ISO 17025.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch reports apply only to the specific samples tested under stated test conditions. Construction of
the actual test samples has been documented. It is the manufacturer's responsibility to assure that additional production units of this model are manufactured with
identical electrical and mechanical components. The manufacturer/importer is responsible to the Competent Authorities in Europe for any modifications made to the
production units which result in non-compliance to the relevant regulations. TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch shall have no
liability for any deductions, inferences or generalizations drawn by the client or others from TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch
issued reports.

This report is the confidential property of the client. As a mutual protection to our clients, the public and ourselves, extracts from the test report shall not be
reproduced except in full without our written approval.




EMC_SZ_FR_23.02 FCC                                     TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                                Page 1 of 30
                                           Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2017-06-20                                Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.950.18.0211.01



1 Table of Contents
1     Table of Contents ..................................................................................................................................................2
2     Details about the Test Laboratory .........................................................................................................................3
3     Description of the Equipment under Test ..............................................................................................................4
4     Summary of Test Standards .................................................................................................................................5
5     Summary of Test Results ......................................................................................................................................6
6     General Remarks ..................................................................................................................................................7
7     Test Setups ...........................................................................................................................................................8
8     Systems test configuration ....................................................................................................................................9
9     Technical Requirement ...................................................................................................................................... 10
    9.1      Conducted Emission .................................................................................................................................. 10
    9.2      Conducted AV output power ...................................................................................................................... 13
    9.3      6dB bandwidth ............................................................................................................................................ 14
    9.4      99% bandwidth ........................................................................................................................................... 16
    9.5      Power spectral density ............................................................................................................................... 18
    9.6      Spurious RF conducted emissions ............................................................................................................. 20
    9.7      Band edge .................................................................................................................................................. 23
    9.8      Spurious radiated emissions for transmitter ............................................................................................... 25
10        Test Equipment List........................................................................................................................................ 29
11        System Measurement Uncertainty ................................................................................................................. 30




EMC_SZ_FR_23.02 FCC                                   TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                                 Page 2 of 30
                                         Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2017-06-20                              Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.950.18.0211.01



2 Details about the Test Laboratory
Details about the Test Laboratory
Test Site 1

Company name:         TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch
                      Building 12&13, Zhiheng Wisdomland Business Park,
                      Nantou Checkpoint Road 2, Nanshan District,
                      Shenzhen City, 518052,
                      P. R. China

FCC Registration      514049
Number:

IC Registration       10320A-1
Number:

Telephone:            86 755 8828 6998
Fax:                  86 755 8828 5299




EMC_SZ_FR_23.02 FCC                   TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                Page 3 of 30
                         Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2017-06-20              Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.950.18.0211.01



3 Description of the Equipment under Test

Product:                          Camera

Model no.:                        SPTM1

IC:                               10193A-SPTM1

FCC ID:                           CNFSPTM1

Rating:                           3.85Vdc

RF Transmission                   2402MHz-2480MHz
Frequency:
No. of Operated Channel:          40

Modulation:                       GFSK

Antenna Type:                     Integrated Metal Antenna

Antenna Gain:                     0.5dBi max for 2.4GHz

Description of the EUT:           The Equipment Under Test (EUT) is a Camera supports 2.4GHz
                                  Bluetooth/WIFI, 5GHz WIFI functions.




EMC_SZ_FR_23.02 FCC                    TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                Page 4 of 30
                          Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2017-06-20               Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.950.18.0211.01



4 Summary of Test Standards

                                         Test Standards
FCC Part 15 Subpart C       PART 15 - RADIO FREQUENCY DEVICES
10-1-2017 Edition           Subpart C - Intentional Radiators
RSS-Gen Issue 5             RSS-Gen — General Requirements for Compliance of Radio
April 2018                  Apparatus
RSS-247 Issue 2             Digital Transmission Systems (DTS), Frequency Hopping Systems
February 2017               (FHSS) and License-Exempt Local Area Network (LE-LAN) Devices

All the test methods were according to KDB558074 D01 DTS Meas Guidance v04 and ANSI
C63.10 (2013).




EMC_SZ_FR_23.02 FCC                   TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                Page 5 of 30
                         Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2017-06-20              Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.950.18.0211.01



5 Summary of Test Results

                             Technical Requirements
FCC Part 15 Subpart C/RSS-247 Issue 2/RSS-Gen Issue 5
Test Condition                                        Pages                                             Test Result         Test
                                                                                                                             Site
§15.207            RSS-GEN 8.8              Conducted emission AC                          10                Pass           Site 1
                                            power port
§15.247(b)(1)      RSS-247                  Conducted AV output                             --                N/A             --
                   Clause 5.4(b)            power for FHSS
§15.247(b)(3)      RSS-247                  Conducted AV output                            13                Pass           Site 1
                   Clause 5.4(d)            power for DTS
§15.247(e)         RSS-247                  Power spectral density                         18                Pass           Site 1
                   Clause 5.2(b)
§15.247(a)(2)      RSS-247                  6dB bandwidth                                  14                Pass           Site 1
                   Clause 5.2(a)
§15.247(a)(1)      RSS-247                  20dB Occupied                                   --                N/A             --
                   Clause 5.1(a)            bandwidth
--                 RSS-GEN 6.7              99% Occupied                                   16                Pass           Site 1
                                            Bandwidth
§15.247(a)(1)   RSS-247                     Carrier frequency                               --                N/A             --
                Clause 5.1(b)               separation
§15.247(a)(1)(i RSS-247                     Number of hopping                               --                N/A             --
ii)             Clause 5.1(d)               frequencies
§15.247(a)(1)(i RSS-247                     Dwell Time                                      --                N/A             --
ii)             Clause 5.1(d)
§15.247(d)      RSS-247                     Spurious RF conducted                          20                Pass           Site 1
                Clause 5.5                  emissions
§15.247(d)      RSS-247                     Band edge                                      23                Pass           Site 1
                Clause 5.5
§15.247(d) &    RSS-247                     Spurious radiated                              25                Pass           Site 1
§15.209 &       Clause 5.5 &                emissions for transmitter
§15.205         RSS-GEN 6.13
                RSS-GEN 8.9
                RSS-GEN 8.10
§15.203         RSS-GEN 6.8                 Antenna requirement                          See                 Pass             --
                                                                                        note 1

Remark 1: N/A – Not Applicable.
Note 1: The EUT uses an Integrated Metal Antenna 0.5dBi max. According to §15.203, it is considered
sufficiently to comply with the provisions of this section.




EMC_SZ_FR_23.02 FCC                   TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                Page 6 of 30
                         Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2017-06-20              Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.950.18.0211.01



6 General Remarks

Remarks

This submittal(s) (test report) is intended for FCC ID: CNFSPTM1, IC: 10193A-SPTM1, complies with
Section 15.207, 15.209, 15.205, 15.247 of the FCC Part 15, Subpart C and RSS 247 and RSS-Gen
rules.
The Model: SPTM1 supports Bluetooth BR+EDR/Bluetooth Low Energy/WIFI/GPS & Galileo receiving
functions, power by 3.85Vdc, 1220mAh supplied by an internal rechargeable Lithium Ion Battery or
5Vdc supplied by USB type C port.
The TX and RX range is 2402MHz-2480MHz for Bluetooth, 2412MHz – 2462MHz for 2.4GHzWIFI,
5180MHz – 5320MHz, 5500MHz – 5700MHz, 5745MHz – 5825MHz for 5GHzWIFI, 1575.42MHz for
GNSS (only GPS and Galileo) Receiver, also supports two versions (Version W and Version S), the
Version W is identical with the Version S except of the Version S is Dark grey color with GPS & Galileo
receiving function, supported resolutions:4K/30fps, 1440/30fps, 1440/60fps and 960/90fps. The Version
W is Light grey color without GPS & Galileo receiving function; supported resolutions: 1440/30fps and
1440/60fps, therefore Spurious Emissions was tested with the two versions, and the others test items
were only performed on the Version S.

This report is for the Bluetooth Low Energy part.

SUMMARY:

All tests according to the regulations cited on page 5 were

 - Performed

 - Not Performed

The Equipment under Test

 - Fulfills the general approval requirements.

 - Does not fulfill the general approval requirements.

Sample Received Date:                         May 09, 2018

Testing Start Date:                           May 09, 2018

Testing End Date:                            June 06, 2018

- TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch -
Reviewed by:                            Prepared by:                                          Tested by:




   _______________________                      _______________________                        _______________________
        Phoebe Hu                                   Aaron Lai                                           Louise Liu
    EMC Project Manager                         EMC Project Engineer                                 EMC Test Engineer


EMC_SZ_FR_23.02 FCC                    TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                Page 7 of 30
                          Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2017-06-20               Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.950.18.0211.01



7 Test Setups

7.1 Radiated test setups

Below 1GHz




Above 1GHz




7.2 Conducted RF test setups

                   Measuring receiver                           EUT



7.3 AC Power Line Conducted Emission test setups




EMC_SZ_FR_23.02 FCC                   TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                Page 8 of 30
                         Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2017-06-20              Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.950.18.0211.01



8 Systems test configuration

Auxiliary Equipment Used during Test:

            DESCRIPTION              MANUFACTURER                        MODEL NO.                               S/N
                Laptop                       Lenovo                          T460S                               ---

           USB Type C cable                  GoPro                     0.55m (Length)                            ---

              AC Adapter                      Apple                          A1401                               ---


Test software information:
           Test Software Version          QRCT (V3.0-00230) from QUALCOMM

                Modulation                           Setting TX Power                                Packet Type
                  GFSK                                          /                                            /


The system was configured to channel 0, 19, and 39 for the test.




EMC_SZ_FR_23.02 FCC                     TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                Page 9 of 30
                           Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2017-06-20                Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.950.18.0211.01



9 Technical Requirement
9.1
9.1 Conducted Emission

Test Method
   1. The EUT was placed on a table, which is 0.8m above ground plane
   2. The power line of the EUT is connected to the AC mains through a Artificial Mains
      Network (A.M.N.).
   3. Maximum procedure was performed to ensure EUT compliance
   4. A EMI test receiver is used to test the emissions from both sides of AC line

Limit

                         Frequency                        QP Limit                        AV Limit
                            MHz                            dBμV                            dBμV
                         0.150-0.500                       66-56*                          56-46*
                           0.500-5                           56                              46
                             5-30                            60                              50
Decreasing linea




EMC_SZ_FR_23.02 FCC                   TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                Page 10 of 30
                         Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2017-06-20              Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.950.18.0211.01



Conducted Emission

Product Type                       :   Camera
M/N                                :   SPTM1
Operating Condition                :   Charging + TX
Test Specification                 :   Power Line, Live
Comment                            :   AC 120V/60Hz (External adapter)



                              80

                              70

                              60
              Level in dBµV




                              50

                              40

                              30

                              20

                              10

                              0
                              150k       3 0 0 4 0 05 0 0    8 0 01 M             2M    3M 4M 5M 6          8 10M           20M 30M
                                                                          F re q u e n c y in H z

                                       Frequency        MaxPeak         Average     Limit     Margin     Line     Corr.
                                          (MHz)          (dBµV)          (dBµV)    (dBµV)      (dB)               (dB)
                                        0.278000          43.98            ---      60.88     16.89        L1     10.2
                                        0.418000          42.51            ---      57.49     14.98        L1     11.4
                                        0.554000          38.77            ---      56.00     17.23        L1     10.2
                                        0.706000          39.33            ---      56.00     16.67        L1     10.2
                                        1.222000          40.16            ---      56.00     15.84        L1     10.2
                                        3.930000          37.58            ---      56.00     18.42        L1     10.3


Remark: “*” Correct factor=cable loss + LISN factor




EMC_SZ_FR_23.02 FCC                                  TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                Page 11 of 30
                                        Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2017-06-20                             Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.950.18.0211.01



Conducted Emission

Product Type                         :   Camera
M/N                                  :   SPTM1
Operating Condition                  :   Charging + TX
Test Specification                   :   Power Line, Neutral
Comment                              :   AC 120V/60Hz (External adapter)



                              80

                              70

                              60
              Level in dBµV




                              50

                              40

                              30

                              20

                              10

                              0
                              150k         3 0 0 4 0 05 0 0   8 0 01 M             2M    3M 4M 5M 6           8 10M            20M 30M
                                                                           F re q u e n c y in H z

                                         Frequency        MaxPeak        Average      Limit     Margin     Line     Corr.
                                            (MHz)          (dBµV)         (dBµV)     (dBµV)      (dB)               (dB)
                                          0.286000          44.27           ---       60.64     16.37        N      10.3
                                          0.426000          42.64           ---       57.33     14.69        N      10.3
                                          0.694000          40.05           ---       56.00     15.95        N      10.4
                                          1.114000          39.51           ---       56.00     16.49        N      10.4
                                          1.626000          38.98           ---       56.00     17.02        N      10.4
                                          2.182000          35.31           ---       56.00     20.69        N      10.4


Remark: “*” Correct factor=cable loss + LISN factor




EMC_SZ_FR_23.02 FCC                                    TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                Page 12 of 30
                                          Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2017-06-20                               Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.950.18.0211.01




9.2 Conducted AV output power

Test Method
   1. Setting the highest output power level of the EUT:
   2. Connect to gated RF power meter.

Test Setup

                             EUT                                          Power Meter

Limits
According to §15.247 (b) (3), conducted AV output power limit as below:

                      Frequency Range                        Limit                          Limit
                            MHz                               W                             dBm
                         2400-2483.5                          ≤1                             ≤30

Test result as below table

                                                        Conducted AV
                      Frequency                         Output Power                              Result
                          MHz                                   dBm
                 Top channel 2402MHz                            3.10                                Pass
                Middle channel 2440MHz                          3.10                                Pass
                Bottom channel 2480MHz                          2.70                                Pass




EMC_SZ_FR_23.02 FCC                   TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                Page 13 of 30
                         Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2017-06-20              Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.950.18.0211.01




9.3 6dB bandwidth
Test Method
   1. Use the following spectrum analyzer settings:
      RBW=100K, VBW≥3RBW, Sweep = auto, Detector function = peak, Trace = max hold
   2. Use the automatic bandwidth measurement capability of an instrument, may be
      employed using the X dB bandwidth mode with X set to 6 dB, care shall be taken so that
      the bandwidth measurement is not influenced by any intermediate power nulls in the
      fundamental emission that might be ≥ 6 dB.
   3. Allow the trace to stabilize, record the X dB Bandwidth value.
Limit

                                                            Limit [kHz]

                                                                ≥500

Test result
           Test Mode           Channel (MHz)                     Result (MHz)                     Limit (KHz)            Verdict
              BLE                       2402                         0.684                            ≥500               PASS
              BLE                       2440                         0.692                            ≥500               PASS
              BLE                       2480                         0.692                            ≥500               PASS


Test Graphs
                                                         BLE_Ant1_2402




                       D ate:30.M A Y .2018 10:20:53




EMC_SZ_FR_23.02 FCC                       TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                Page 14 of 30
                             Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2017-06-20                  Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.950.18.0211.01



                                                        BLE_Ant1_2440




                      D ate:30.M A Y .2018 10:22:23


                                                        BLE_Ant1_2480




                      D ate:30.M A Y .2018 10:23:54




EMC_SZ_FR_23.02 FCC                      TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                Page 15 of 30
                            Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2017-06-20                 Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.950.18.0211.01




9.4 99% bandwidth
Test Method
   4. Use the following spectrum analyzer settings:
      RBW=100K, VBW≥3RBW, Sweep = auto, Detector function = peak, Trace = max hold
   5. Use the automatic bandwidth measurement capability of an instrument, may be
      employed using the OBW bandwidth mode.
   6. Allow the trace to stabilize, record the OBW Bandwidth value.
Limit

                                                            Limit [kHz]

                                                                   --

Test result
           Test Mode            Channel (MHz                     Result (MHz)                         Limit              Verdict
              BLE                       2402                            1.063                          ---               PASS
              BLE                       2440                            1.059                          ---               PASS
              BLE                       2480                            1.059                          ---               PASS


Test Graphs
                                                         BLE_Ant1_2402




                       D ate:30.M A Y .2018 10:21:04




EMC_SZ_FR_23.02 FCC                       TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                Page 16 of 30
                             Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2017-06-20                  Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.950.18.0211.01



                                                        BLE_Ant1_2440




                      D ate:30.M A Y .2018 10:22:34


                                                        BLE_Ant1_2480




                      D ate:30.M A Y .2018 10:24:05




EMC_SZ_FR_23.02 FCC                      TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                Page 17 of 30
                            Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2017-06-20                 Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.950.18.0211.01




9.5 Power spectral density
Test Method
This procedure shall be used if maximum peak conducted output power was used to
demonstrate compliance:
   1. Set analyzer center frequency to DTS channel center frequency.
       RBW=100kHz,VBW≥3RBW,Span=1.5 times DTS bandwidth, Detector=Peak,
       Sweep=auto,
       Trace= max hold.
   2. Allow trace to fully stabilize, use the peak marker function to determine the maximum
       amplitude level within the RBW .
   3. Repeat above procedures until other frequencies measured were completed.
Limit

                                                           Limit [dBm]

                                                                  ≤8


Test result
           Test Mode           Channel (MHz)                     Result (dBm)                         Limit              Verdict
              BLE                       2402                           1.30                             8                PASS
              BLE                       2440                           1.18                             8                PASS
              BLE                       2480                           0.83                             8                PASS

Test Graphs
                                                         BLE_Ant1_2402




                       D ate:30.M A Y .2018 10:21:17




EMC_SZ_FR_23.02 FCC                       TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                Page 18 of 30
                             Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2017-06-20                  Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.950.18.0211.01



                                                        BLE_Ant1_2440




                      D ate:30.M A Y .2018 10:22:47


                                                        BLE_Ant1_2480




                      D ate:30.M A Y .2018 10:24:18




EMC_SZ_FR_23.02 FCC                      TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                Page 19 of 30
                            Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2017-06-20                 Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.950.18.0211.01




9.6 Spurious RF conducted emissions
Test Method
   1. Establish a reference level by using the following procedure:
      a. Set RBW=100 kHz. VBW≥3RBW. Detector =peak, Sweep time = auto couple, Trace
         mode = max hold.
      b. Allow trace to fully stabilize, use the peak marker function to determine the maximum
         PSD level.
   2. Use the maximum PSD level to establish the reference level.
      a. Set the center frequency and span to encompass frequency range to be measured.
      b. Use the peak marker function to determine the maximum amplitude level. Ensure that
         the amplitude of all unwanted emissions outside of the authorized frequency band
         (excluding restricted frequency bands) are attenuated by at least the minimum
         requirements, report the three highest emissions relative to the limit.
   3. Repeat above procedures until other frequencies measured were completed.

Limit

                                    Frequency Range                          Limit (dBc)
                                          MHz
                                        30-25000                                   -20

Test Result
                        Channel         Freq Range                                                   Limit
            Test Mode                                                 Result (dBm)                                Verdict
                         (MHz)             (MHz)                                                    (dBm)
              BLE         2402           30~1000                          -68.81                     -18.7         PASS
              BLE         2402          1000~26500                        -43.28                     -18.7         PASS
              BLE         2440           30~1000                           -68.6                    -18.83         PASS
              BLE         2440          1000~26500                        -43.02                    -18.83         PASS
              BLE         2480           30~1000                          -68.83                    -19.18         PASS
              BLE         2480          1000~26500                        -43.17                    -19.18         PASS




EMC_SZ_FR_23.02 FCC                   TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                Page 20 of 30
                         Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2017-06-20              Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.950.18.0211.01



Test Graphs
                                                       BLE_Ant1_2402_30~1000_1.30




                      D ate:30.M A Y .2018 10:21:42


                                                      BLE_Ant1_2402_1000~26500_1.30




                      D ate:30.M A Y .2018 10:21:51


                                                       BLE_Ant1_2440_30~1000_1.17




                      D ate:30.M A Y .2018 10:23:01




EMC_SZ_FR_23.02 FCC                      TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                Page 21 of 30
                            Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2017-06-20                 Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.950.18.0211.01



                                                      BLE_Ant1_2440_1000~26500_1.17




                      D ate:30.M A Y .2018 10:23:10


                                                       BLE_Ant1_2480_30~1000_0.82




                      D ate:30.M A Y .2018 10:24:41


                                                      BLE_Ant1_2480_1000~26500_0.82




                      D ate:30.M A Y .2018 10:24:50




EMC_SZ_FR_23.02 FCC                      TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                Page 22 of 30
                            Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2017-06-20                 Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.950.18.0211.01




9.7 Band edge
Test Method
   1 Use the following spectrum analyzer settings:
      Span = wide enough to capture the peak level of the in-band emission and all spurious
      RBW = 100 kHz, VBW≥RBW, Sweep = auto, Detector function = peak, Trace = max
      hold.
   2 Allow the trace to stabilize, use the peak and delta measurement to record the result.
   3 The level displayed must comply with the limit specified in this Section.

Limit
                                     Frequency Range                          Limit (dBc)
                                           MHz
                                         30-25000                                    -20

Test result
              Test Mode   Ch Name         Channel (MHz)                 Result (dBm)                 Limit        Verdict
                BLE         Low                 2402                         -55.6                  -18.66        PASS
                BLE         High                2480                        -58.15                  -19.35        PASS




EMC_SZ_FR_23.02 FCC                    TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                  Page 23 of 30
                          Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2017-06-20               Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.950.18.0211.01



Test Graphs
                                                      BLE_Ant1_Low_2402_1.34




                      D ate:30.M A Y .2018 10:21:27


                                                      BLE_Ant1_High_2480_0.65




                      D ate:30.M A Y .2018 10:24:27




EMC_SZ_FR_23.02 FCC                      TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                Page 24 of 30
                            Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2017-06-20                 Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.950.18.0211.01




9.8 Spurious radiated emissions for transmitter

Test Method
   1: The EUT was place on a turn table which is 1.5m above ground plane for above 1GHz
   and 0.8m above ground for below 1GHz at 3 meter chamber room for test. The table was
   rotated 360 degrees to determine the position of the highest radiation.
   2: The EUT was set 3 meters away from the interference – receiving antenna, which was
   mounted on the top of a variable – height antenna tower.
   3: The height of antenna is varied from one meter to four meters above the ground to
   determine the maximum value of the field strength. Both horizontal and vertical polarizations
   of the antenna are set to make the measurement.
   4: For each suspected emission, the EUT was arranged to its worst case and then the
   antenna was tuned to heights from 1 meter to 4 meters and the rotatable table was turned
   from 0 degrees to 360 degrees to find the maximum reading.
   5: Use the following spectrum analyzer settings According to C63.10:
   For Above 1GHz
       Span = wide enough to capture the peak level of the in-band emission and all spurious
       RBW = 1MHz, VBW≥RBW for peak measurement and VBW = 10Hz for average
       measurement, Sweep = auto, Detector function = peak, Trace = max hold.
   For Below 1GHz
   Use the following spectrum analyzer settings:
       Span = wide enough to capture the peak level of the in-band emission and all spurious
       RBW = 100 KHz, VBW≥RBW for peak measurement, Sweep = auto, Detector function =
       peak, Trace = max hold.
Note:
       1: The resolution bandwidth and video bandwidth of test receiver/spectrum analyzer is
       120 KHz for Quasi-peak detection (QP) at frequency below 1GHz.
       2: The resolution bandwidth of test receiver/spectrum analyzer is 1MHz and the video
       bandwidth is 3MHz for peak detection (PK) at frequency above 1GHz.
       3: The resolution bandwidth of test receiver/spectrum analyzer is 1MHz and the video
       bandwidth is 3MHz for RMS Average ((duty cycle ˂ 98%) for Average detection (AV) at
       frequency above 1GHz, then the measurement results was added to a correction factor
       (20log(1/duty cycle)).
       4: The resolution bandwidth of test receiver/spectrum analyzer is 1MHz and the video
       bandwidth is 10Hz (duty cycle ˃ 98%) for Average detection (AV) at frequency above
       1GHz.




EMC_SZ_FR_23.02 FCC                   TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                Page 25 of 30
                         Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2017-06-20              Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.950.18.0211.01




Limit

The radio emission outside the operating frequency band shall be at least 20 dB below that in
the 100 kHz bandwidth within the band that contains the highest level of the desired power.
Radiated emissions which fall in the restricted bands, as defined in section15.205, must comply
with the radiated emission limits specified in section 15.209.

              Frequency                 Field Strength                 Field Strength                       Detector
                  MHz                        uV/m                         dBμV/m
                  30-88                       100                            40                                 QP
                 88-216                       150                           43.5                                QP
                216-960                       200                            46                                 QP
               960-1000                       500                            54                                 QP
              Above 1000                      500                            54                                 AV
              Above 1000                     5000                            74                                 PK




EMC_SZ_FR_23.02 FCC                     TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                Page 26 of 30
                           Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2017-06-20                Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.950.18.0211.01



Spurious radiated emissions for transmitter

According to C63.10, if the peak (or quasi-peak) measured value complies with the average limit,
it is unnecessary to perform an average measurement, so AV emission value did not show in
below table if the peak value complies with average limit.

Transmitting spurious emission test result as below:
SPTM1 (Version S)
2402MHz (30MHz – 1GHz)
                     Emission
       Frequency                      Polarization           Limit           Margin         Detector         Corr.       Result
                       Level
          MHz         dBuV/m                               dBμV/m              dB                             dB
         231.16        33.35           Horizontal           46.00             12.65             QP           -28.1        Pass
         232.99        33.75            Vertical            46.00             12.25             QP           -26.8        Pass

2402MHz (Above 1GHz)
                      Emission
        Frequency                     Polarization            Limit          Margin        Detector         Corr.        Result
                        Level
          MHz          dBuV/m                               dBμV/m             dB                           dB/m
         4851.56        36.76           Horizontal           74.00            37.24            PK            2.5         Pass
         4822.96        37.09            Vertical            74.00            36.91            PK            2.7         Pass

2440MHz (30MHz – 1GHz)
                     Emission
       Frequency                      Polarization           Limit           Margin         Detector         Corr.       Result
                       Level
          MHz         dBuV/m                               dBμV/m               dB                            dB
           --            --            Horizontal            --                  --             QP             --         Pass
           --            --             Vertical             --                  --             QP             --         Pass

2440MHz (Above 1GHz)
                      Emission
        Frequency                     Polarization            Limit          Margin        Detector         Corr.        Result
                        Level
          MHz          dBuV/m                               dBμV/m             dB                           dB/m
         4905.93        37.22           Horizontal           74.00            36.78            PK            2.5         Pass
         4237.96        35.77            Vertical            74.00            38.23            PK            0.7         Pass

2480MHz (30MHz – 1GHz)
                     Emission
       Frequency                      Polarization           Limit           Margin         Detector         Corr.       Result
                       Level
          MHz         dBuV/m                               dBμV/m               dB                            dB
           --            --            Horizontal            --                  --             QP             --         Pass
           --            --             Vertical             --                  --             QP             --         Pass

2480MHz (Above 1GHz)
                      Emission
        Frequency                     Polarization            Limit          Margin        Detector         Corr.        Result
                        Level
          MHz          dBuV/m                               dBμV/m             dB                           dB/m
         4502.81        36.27           Horizontal           74.00            37.73            PK            1.5         Pass
         4823.90        36.73            Vertical            74.00            37.27            PK            2.6         Pass




EMC_SZ_FR_23.02 FCC                   TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                 Page 27 of 30
                         Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2017-06-20              Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.950.18.0211.01



SPTM1 (Version W)
2402MHz (30MHz – 1GHz)
                       Emission
        Frequency                       Polarization           Limit           Margin         Detector         Corr.       Result
                         Level
           MHz          dBuV/m                               dBμV/m              dB                             dB
          103.23         30.13           Horizontal           43.50             13.37             QP           -28.0        Pass
          32.10          24.14            Vertical            40.00             15.86             QP           -25.4        Pass

2402MHz (Above 1GHz)
                        Emission
        Frequency                       Polarization            Limit          Margin        Detector         Corr.        Result
                          Level
           MHz           dBuV/m                               dBμV/m             dB                           dB/m
          7491.09         40.48           Horizontal           74.00            33.52            PK            6.6         Pass
          7027.03         39.24            Vertical            74.00            34.76            PK            6.0         Pass

2440MHz (30MHz – 1GHz)
                       Emission
        Frequency                       Polarization           Limit           Margin         Detector         Corr.       Result
                         Level
           MHz          dBuV/m                               dBμV/m               dB                            dB
            --             --            Horizontal            --                  --             QP             --         Pass
            --             --             Vertical             --                  --             QP             --         Pass

2440MHz (Above 1GHz)
                        Emission
        Frequency                       Polarization            Limit          Margin        Detector         Corr.        Result
                          Level
           MHz           dBuV/m                               dBμV/m             dB                           dB/m
          7590.93         40.76           Horizontal           74.00            33.24            PK            6.4         Pass
          7029.37         40.01            Vertical            74.00            33.99            PK            6.1         Pass

2480MHz (30MHz – 1GHz)
                       Emission
        Frequency                       Polarization           Limit           Margin         Detector         Corr.       Result
                         Level
           MHz          dBuV/m                               dBμV/m               dB                            dB
            --             --            Horizontal            --                  --             QP             --         Pass
            --             --             Vertical             --                  --             QP             --         Pass

2480MHz (Above 1GHz)
                        Emission
        Frequency                       Polarization            Limit          Margin        Detector         Corr.        Result
                          Level
           MHz           dBuV/m                               dBμV/m             dB                           dB/m
          7069.68         38.32           Horizontal           74.00            35.68            PK            2.5         Pass
          7038.75         40.18            Vertical            74.00            33.82            PK            0.7         Pass

Remark:
      (1) “*” means the emission(s) appear within the restrict bands shall follow the requirement of section
          15.205.
      (2) Data of measurement within this frequency range shown “--” in the table above means the reading of
          emissions are the noise floor or attenuated more than 10dB below the permissible limits or the field
          strength is too small to be measured.
      (3) Above 1GHz: Corrector factor = Antenna Factor + Cable Loss- Amplifier Gain.
      (4) Below 1GHz: Corrector factor = Antenna Factor + Cable Loss.




EMC_SZ_FR_23.02 FCC                     TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                 Page 28 of 30
                           Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2017-06-20                Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.950.18.0211.01



10 Test Equipment List
Radiated Emission Test
         DESCRIPTION                 MANUFACTURER                    MODEL NO.               SERIAL NO.             CAL. DUE DATE
        EMI Test Receiver            Rohde & Schwarz                  ESR 26                   101269                 2018-7-14
  Trilog Super Broadband Test
                                         Schwarzbeck                 VULB 9163                     707                   2018-7-14
            Antenna
          Horn Antenna                Rohde & Schwarz                    HF907                  102294                   2018-7-14
         Pre-amplifier                Rohde & Schwarz                   SCU 18                 102230                    2018-7-14
       Signal Generator               Rohde & Schwarz                   SMY01               839369/005                    2018-7-7
          Attenuator                      Agilent                       8491A               MY39264334                    2018-7-7
   3m Semi-anechoic chamber                TDK                          9X6X6                    ----                     2020-7-7
         Test software                Rohde & Schwarz                   EMC32              Version 9.15.00                  N/A

Conducted Emission Test
      DESCRIPTION                  MANUFACTURER                     MODEL NO.               SERIAL NO.              CAL. DUE DATE
     EMI Test Receiver             Rohde & Schwarz                     ESR 3                  101782                  2018-7-14
           LISN                    Rohde & Schwarz                    ENV4200                 100249                  2018-7-14
           LISN                    Rohde & Schwarz                    ENV432                  101318                  2018-7-14
           LISN                    Rohde & Schwarz                    ENV216                  100326                  2018-7-14
           ISN                     Rohde & Schwarz                     ENY81                  100177                  2018-7-14
           ISN                     Rohde & Schwarz                   ENY81-CA6                101664                  2018-7-14
                                                                    TK9420(VT94
     High Voltage Probe             Rohde & Schwarz                                           9420-584                   2018-7-14
                                                                        20)
      RF Current Probe              Rohde & Schwarz                    EZ-17                  100816                     2018-7-14
         Attenuator                Shanghai Huaxiang                  TS2-26-3              080928189                     2018-7-7
       Test software                Rohde & Schwarz                    EMC32               Version9.15.00                   N/A

TS8997 Test System
       DESCRIPTION              MANUFACTURER                       MODEL NO.                   SERIAL NO.            CAL. DUE DATE
      Signal Generator          Rohde & Schwarz                     SMB100A                      108272                 2018-7-7
   Vector Signal Generator      Rohde & Schwarz                    SMBV100A                      262825                2018-7-23
       Communication            Rohde & Schwarz
      Synthetical Test                                               CMW 270                      101251                     2019-2-15
         Instrument
       Signal Analyzer           Rohde & Schwarz                  FSV40                          101030                       2018-7-7
   Vector Signal Generator       Rohde & Schwarz                 SMU 200A                        105324                       2018-7-7
     RF Switch Module            Rohde & Schwarz              OSP120/OSP-B157                101226/100851                    2018-7-7
        Power Splitter              Weinschel                      1580                          SC319                        2018-7-7
      10dB Attenuator               Weinschel                      56-10                         58764                       2018-7-14
      10dB Attenuator                 R&S                          DNF                          DNF-001                      2018-7-14
      10dB Attenuator                 R&S                          DNF                          DNF-002                      2018-7-14
      10dB Attenuator                 R&S                          DNF                          DNF-003                      2018-7-14
      10dB Attenuator                 R&S                          DNF                          DNF-004                      2018-7-14
                                                                                                Version                         N/A
        Test software            Rohde & Schwarz                      EMC32
                                                                                                10.38.00
        Test software                  Tonscend               System for BT/WIFI                Version 2.6                    N/A




EMC_SZ_FR_23.02 FCC                       TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                  Page 29 of 30
                             Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2017-06-20                  Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.950.18.0211.01



11 System Measurement Uncertainty

For a 95% confidence level, the measurement expanded uncertainties for defined systems, in
accordance with the recommendations of ISO 17025 were:

                                        System Measurement Uncertainty
                                Items                                                          Extended Uncertainty
 Uncertainty for Radiated Spurious Emission 25MHz-3000MHz                             Horizontal: 4.80dB;
                                                                                      Vertical: 4.87dB;
 Uncertainty for Radiated Spurious Emission 3000MHz-18000MHz                          Horizontal: 4.59dB;
                                                                                      Vertical: 4.58dB;
 Uncertainty for Radiated Spurious Emission 18000MHz-40000MHz                         Horizontal: 5.05dB;
                                                                                      Vertical: 5.04dB;
 Uncertainty for Conducted RF test with TS 8997                                       Power level test involved: 2.13dB
                                                                                      Frequency test involved:
                                                                                      0.6×10-7
 Uncertainty for Conducted Emission 150kHz-30MHz (for test using                      3.21dB
 AMN ENV432 or ENV4200)




EMC_SZ_FR_23.02 FCC                    TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                Page 30 of 30
                          Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2017-06-20               Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299



Document Created: 2018-06-26 17:48:40
Document Modified: 2018-06-26 17:48:40

© 2024 FCC.report