RF test report of BLE

FCC ID: CNFSPCC1

Test Report

Download: PDF
FCCID_4313045

Report Number: 68.950.19.0508.01




                                                               FCC - TEST REPORT



Report Number                                    :     68.950.19.0508.01                                 Date of Issue:                        May 13, 2019


 Model                                           :     SPCC1

 Product Type                                    :     Camera

 Applicant                                       :     GoPro, Inc.

 Address                                         :     3000 Clearview Way, San Mateo, CA 94402, USA

 Production Facility                             :     GoPro, Inc.

 Address                                         :     3000 Clearview Way, San Mateo, CA 94402, USA


Test Result                                      :     n Positive                      o Negative



Total pages including
Appendices                                       :     32




TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch is a subcontractor to TÜV SÜD Product Service GmbH according to the principles outlined in
ISO 17025.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch reports apply only to the specific samples tested under stated test conditions. Construction of
the actual test samples has been documented. It is the manufacturer's responsibility to assure that additional production units of this model are manufactured with
identical electrical and mechanical components. The manufacturer/importer is responsible to the Competent Authorities in Europe for any modifications made to the
production units which result in non-compliance to the relevant regulations. TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch shall have no
liability for any deductions, inferences or generalizations drawn by the client or others from TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch
issued reports.

This report is the confidential property of the client. As a mutual protection to our clients, the public and ourselves, extracts from the test report shall not be
reproduced except in full without our written approval.




EMC_SZ_FR_23.02 FCC                                    TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                                 Page 1 of 32
                                          Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2017-06-20                               Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.950.19.0508.01



1 Table of Contents
1     Table of Contents......................................................................................................................................................... 2
2     Details about the Test Laboratory .............................................................................................................................. 3
3     Description of the Equipment under Test ................................................................................................................... 4
4     Summary of Test Standards ....................................................................................................................................... 5
5     Summary of Test Results ............................................................................................................................................ 6
6     General Remarks ......................................................................................................................................................... 7
7     Test Setups .................................................................................................................................................................. 8
8     Systems test configuration .......................................................................................................................................... 9
9     Technical Requirement.............................................................................................................................................. 10
    9.1      Conducted Emission ......................................................................................................................................... 10
    9.2      Conducted peak output power ............................................................................................................................... 13
    9.3      6dB bandwidth ................................................................................................................................................... 14
    9.4      99% bandwidth .................................................................................................................................................. 16
    9.5      Power spectral density ...................................................................................................................................... 18
    9.6      Spurious RF conducted emissions ................................................................................................................... 20
    9.7      Band edge .......................................................................................................................................................... 25
    9.8      Spurious radiated emissions for transmitter .................................................................................................... 27
10        Test Equipment List ............................................................................................................................................... 31
11        System Measurement Uncertainty ....................................................................................................................... 32




EMC_SZ_FR_23.02 FCC                                     TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                                      Page 2 of 32
                                           Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2017-06-20                                Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.950.19.0508.01



2 Details about the Test Laboratory
Details about the Test Laboratory
Test Site 1

Company name:         TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch
                      Building 12&13, Zhiheng Wisdomland Business Park,
                      Nantou Checkpoint Road 2, Nanshan District,
                      Shenzhen City, 518052,
                      P. R. China

FCC Designation       CN5009
Number:

FCC Registration      514049
No.:

Telephone:            86 755 8828 6998
Fax:                  86 755 8828 5299




EMC_SZ_FR_23.02 FCC                   TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                Page 3 of 32
                         Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2017-06-20              Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.950.19.0508.01



3 Description of the Equipment under Test

Product:                          Camera

Model no.:                        SPCC1

FCC ID:                           CNFSPCC1

Rating:                           3.85VDC

RF Transmission                   2402MHz-2480MHz
Frequency:
No. of Operated Channel:          40

Modulation:                       GFSK

Antenna Type:                     Internal Integrated Metal Antenna

Antenna Gain:                     0.1dBi max for 2.4GHz

Description of the EUT:           The Equipment Under Test (EUT) is a Camera supports 2.4GHz
                                  Bluetooth/WIFI, 5GHz WIFI functions.




EMC_SZ_FR_23.02 FCC                    TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                Page 4 of 32
                          Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2017-06-20               Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.950.19.0508.01



4 Summary of Test Standards

                                         Test Standards
FCC Part 15 Subpart C       PART 15 - RADIO FREQUENCY DEVICES
10-1-2018 Edition           Subpart C - Intentional Radiators

All the test methods were according to KDB 558074 D01 15.247 Meas Guidance v05r02 and
ANSI C63.10 (2013).




EMC_SZ_FR_23.02 FCC                   TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                Page 5 of 32
                         Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2017-06-20              Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.950.19.0508.01



5 Summary of Test Results

                              Technical Requirements
FCC Part 15 Subpart C
Test Condition                                                                           Pages          Test Result Test Site
§15.207        Conducted emission AC power port                                           10               Pass      Site 1

§15.247(b)(1)      Conducted AV output power for FHSS                                        --               N/A             --

§15.247(b)(3)      Conducted peak output power & EIRP                                       13               Pass          Site 1

§15.247(e)         Power spectral density                                                   18               Pass          Site 1

§15.247(a)(2)      6dB bandwidth                                                            14               Pass          Site 1

§15.247(a)(1)      20dB Occupied bandwidth                                                   --               N/A             --

--                 99% Occupied Bandwidth                                                   16               Pass          Site 1

§15.247(a)(1)      Carrier frequency separation                                              --               N/A             --

§15.247(a)(1)(i Number of hopping frequencies                                                --               N/A             --
ii)
§15.247(a)(1)(i Dwell Time                                                                   --               N/A             --
ii)
§15.247(d)      Spurious RF conducted emissions                                             20               Pass          Site 1

§15.247(d)         Band edge                                                                25               Pass          Site 1

§15.247(d) &       Spurious radiated emissions for transmitter                              27               Pass          Site 1
§15.209 &
§15.205
§15.203            Antenna requirement                                                    See                Pass             --
                                                                                         note 1

Remark 1: N/A – Not Applicable.
Note 1: The EUT uses a Integrated antenna, which gain is 0.1dBi. In accordance to §15.203, it is
considered sufficiently to comply with the provisions of this section.




EMC_SZ_FR_23.02 FCC                   TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                Page 6 of 32
                         Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2017-06-20              Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.950.19.0508.01



6 General Remarks

Remarks

This submittal(s) (test report) is intended for FCC ID: CNFSPCC1, complies with Section 15.207,
15.209, 15.205, 15.247 of the FCC Part 15, Subpart C
The Model: SPCC1 supports Bluetooth Low Energy/WIFI/GPS & Galileo receiving functions, power by
3.85Vdc, 1600mAh supplied by a rechargeable Lithium Ion Battery or 5Vdc supplied by USB type C
port.
The TX and RX range is 2402MHz-2480MHz for Bluetooth, 2412MHz – 2462MHz for 2.4GHzWIFI,
5180MHz – 5320MHz, 5500MHz – 5700MHz, 5745MHz – 5825MHz for 5GHzWIFI, 1575.42MHz for
GNSS (only GPS and Galileo) Receiver supported highest resolutions: 5.6K.
This report is for the Bluetooth Low Energy part.

SUMMARY:

All tests according to the regulations cited on page 5 were

n - Performed

o - Not Performed

The Equipment under Test

n - Fulfills the general approval requirements.

o - Does not fulfill the general approval requirements.

Sample Received Date:                       April 30, 2019

Testing Start Date:                         April 30, 2019

Testing End Date:                            May 10, 2019

- TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch -
Reviewed by:                           Prepared by:                                          Tested by:




   _______________________                     _______________________                        _______________________
         John Zhi                                    Joe Gu                                                 Tree Zhan
    EMC Project Manager                        EMC Project Engineer                                 EMC Test Engineer




EMC_SZ_FR_23.02 FCC                   TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                Page 7 of 32
                         Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2017-06-20              Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.950.19.0508.01



7 Test Setups

7.1 Radiated test setups

Below 1GHz




Above 1GHz




7.2 Conducted RF test setups

                   Measuring receiver                           EUT



7.3 AC Power Line Conducted Emission test setups




EMC_SZ_FR_23.02 FCC                   TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                Page 8 of 32
                         Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2017-06-20              Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.950.19.0508.01



8 Systems test configuration

Auxiliary Equipment Used during Test:

            DESCRIPTION              MANUFACTURER                        MODEL NO.                               S/N
                Laptop                       Lenovo                          T460S                               ---

           USB Type C cable                  GoPro                     0.55m (Length)                            ---

              AC Adapter                      Apple                        A1401                                 ---


Test software information:

           Test Software Version          QRCT (V3.0-00230) from QUALCOMM

                Modulation                           Setting TX Power                                Packet Type
                  GFSK                                          /                                            /


The system was configured to channel 0, 19, and 39 for the test.




EMC_SZ_FR_23.02 FCC                     TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                Page 9 of 32
                           Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2017-06-20                Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.950.19.0508.01



9 Technical Requirement
9.1
9.1 Conducted Emission

Test Method
   1. The EUT was placed 0.4 meter from the conducting wall of the shielding room was kept
      at least 80 centimeters from any other grounded conducting surface.
   2. Connect EUT to the power mains through a line impedance stabilization network (LISN).
   3. All the support units are connecting to the other LISN.
   4. The LISN provides 50 ohm coupling impedance for the measuring instrument.
   5. Both sides of AC line were checked for maximum conducted interference.
   6. The frequency range from 150 kHz to 30 MHz was searched.
   7. Set the test-receiver system to Peak Detect Function and specified bandwidth (IF
      Bandwidth = 9kHz) with Maximum Hold Mode. Then measurement is also conducted by
      Average Detector and Quasi-Peak Detector Function respectively.

Limit
According to §15.207, conducted emissions limit as below:

                         Frequency                        QP Limit                        AV Limit
                            MHz                            dBμV                            dBμV
                         0.150-0.500                       66-56*                          56-46*
                           0.500-5                           56                              46
                            5-30                             60                              50
                  *Decreasing linearly with logarithm of the frequency




EMC_SZ_FR_23.02 FCC                   TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                Page 10 of 32
                         Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2017-06-20              Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.950.19.0508.01



Conducted Emission

Product Type               :   Camera
M/N                        :   SPCC1
Operating Condition        :   Charging + TX
Test Specification         :   Power Line, Live
Comment                    :   AC 120V/60Hz (External adapter)

           80

                   Level in dBµV
           70

           60

           50

           40

           30

           20

           10

            0
            150k          300 400 500          800 1M            2M       3M    4M 5M 6       8 10M            20M     30M
                                                            Frequency in Hz

                               Frequency          MaxPeak*      Average         Limit    Margin     Line    Corr.*
                                 (MHz)             (dBµV)        (dBµV)        (dBµV)     (dB)                 *
                                  0.282000            46.21           ---        60.76     14.55    L1       (dB)
                                                                                                              10.2
                                  0.434000            41.57           ---        57.18     15.60    L1        10.3
                                  0.574000            38.46           ---        56.00     17.54    L1        10.3
                                  0.862000            40.03           ---        56.00     15.97    L1        10.3
                                  1.114000            37.66           ---        56.00     18.34    L1        10.3
                                  3.974000            36.99           ---        56.00     19.01    L1        10.4


Remark:
*Level=Reading Level + Correction Factor
**Correction Factor=Cable Loss + LISN Factor
(The Reading Level is recorded by software which is not shown in the sheet)




EMC_SZ_FR_23.02 FCC                             TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                Page 11 of 32
                                   Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2017-06-20                        Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.950.19.0508.01



Conducted Emission

Product Type              :   Camera
M/N                       :   SPCC1
Operating Condition       :   Charging + TX
Test Specification        :   Power Line, Neutral
Comment                   :   AC 120V/60Hz (External adapter)



                  80

                  70      Level in dBµV


                  60

                  50

                  40

                  30

                  20

                  10

                   0
                   150k         300 400 500        800 1M               2M    3M    4M 5M 6         8 10M           20M        30M
                                                                Frequency in Hz

                              Frequency       MaxPeak*      Average       Limit      Margin     Line    Corr.*
                                (MHz)          (dBµV)        (dBµV)      (dBµV)       (dB)                 *
                                 0.282000         46.66           ---      60.76       14.10    N        (dB)
                                                                                                          10.2
                                 0.422000         42.54           ---      57.41       14.87    N         10.3
                                 0.590000         37.31           ---      56.00       18.69    N         10.3
                                 0.734000         38.06           ---      56.00       17.94    N         10.3
                                 0.882000         39.02           ---      56.00       16.98    N         10.3
                                 1.470000         36.38           ---      56.00       19.62    N         10.3



Remark:
*Level=Reading Level + Correction Factor
**Correction Factor=Cable Loss + LISN Factor
(The Reading Level is recorded by software which is not shown in the sheet)




EMC_SZ_FR_23.02 FCC                         TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                  Page 12 of 32
                               Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2017-06-20                    Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.950.19.0508.01




9.2 Conducted peak output power

Test Method
   1. The RF output of EUT was connected to the test receiver by RF cable. The path loss was
      compensated to the results for each measurement.
   2. Set to the maximum power setting and enable the EUT transmit continuously
   3. Use the following test receiver settings:
      Span = approximately 5 times the 20dB bandwidth, centered on a hopping channel
      RBW > the 20dB bandwidth of the emission being measured, VBW≥RBW,
      Sweep = auto, Detector function = peak, Trace = max hold
   4. Allow the trace to stabilize. Use the marker-to-peak function to set the marker to the
      peak of the emission. The indicated level is the peak output power and record the results
      in the test report.
   5. Repeat above procedures until all frequencies measured were complete.

Limits
According to §15.247 (b) (1), conducted peak output power limit as below:

                      Frequency Range                        Limit                          Limit
                            MHz                               W                             dBm
                         2400-2483.5                          ≤1                             ≤30

Test result as below table


                                                   Conducted Peak
                       Frequency                    Output Power
                                                                                            Result
                         (MHz)                         (dBm)

                       Low channel
                                                           0.60                              Pass
                        2402MHz
                      Middle channel
                                                           1.23                              Pass
                        2440MHz
                       High channel
                                                           1.54                              Pass
                        2480MHz




EMC_SZ_FR_23.02 FCC                   TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                Page 13 of 32
                         Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2017-06-20              Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.950.19.0508.01




9.3 6dB bandwidth
Test Method
   1. Use the following spectrum analyzer settings:
      RBW=100K, VBW≥3RBW, Sweep = auto, Detector function = peak, Trace = max hold
   2. Use the automatic bandwidth measurement capability of an instrument, may be
      employed using the X dB bandwidth mode with X set to 6 dB, care shall be taken so that
      the bandwidth measurement is not influenced by any intermediate power nulls in the
      fundamental emission that might be ≥ 6 dB.
   3. Allow the trace to stabilize, record the X dB Bandwidth value.
Limit

                                                            Limit [kHz]

                                                               ≥500

Test result
           Test Mode       Channel (MHz)                       Result (MHz)                   Limit (KHz)            Verdict
              BLE                     2402                        0.688                           ≥500               PASS
              BLE                     2440                        0.776                           ≥500               PASS
              BLE                     2480                        0.692                           ≥500               PASS


Test Graphs

                                                        BLE_BT4.0_Ant1_2402




                         D ate:6.M A Y .2019 16:29:49




EMC_SZ_FR_23.02 FCC                   TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                Page 14 of 32
                         Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2017-06-20              Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.950.19.0508.01


                                                        BLE_BT4.0_Ant1_2440




                         D ate:6.M A Y .2019 16:32:31


                                                        BLE_BT4.0_Ant1_2480




                         D ate:6.M A Y .2019 16:34:31




EMC_SZ_FR_23.02 FCC                   TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                Page 15 of 32
                         Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2017-06-20              Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.950.19.0508.01




9.4 99% bandwidth
Test Method
      1. Use the following spectrum analyzer settings:
      RBW=1% to 5% of the actual occupied, VBW≥3RBW, Sweep = auto,
      Detector function = peak, Trace = max hold
      2. Use the automatic bandwidth measurement capability of an instrument, care shall be
      taken so that the bandwidth measurement is not influenced by any intermediate power
      nulls in the fundamental emission that might be ≥ 6 dB.
      3. Allow the trace to stabilize, record the X dB Bandwidth value.
Limit

                                                            Limit [kHz]

                                                                --


Test result
           Test Mode        Channel (MHz                       Result (MHz)                       Limit              Verdict
              BLE                     2402                           1.067                         ---               PASS
              BLE                     2440                           1.063                         ---               PASS
              BLE                     2480                           1.063                         ---               PASS

Test Graphs
                                                        BLE_BT4.0_Ant1_2402




                         D ate:6.M A Y .2019 16:30:00




EMC_SZ_FR_23.02 FCC                   TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                Page 16 of 32
                         Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2017-06-20              Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.950.19.0508.01


                                                        BLE_BT4.0_Ant1_2440




                         D ate:6.M A Y .2019 16:32:43


                                                        BLE_BT4.0_Ant1_2480




                         D ate:6.M A Y .2019 16:34:42




EMC_SZ_FR_23.02 FCC                   TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                Page 17 of 32
                         Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2017-06-20              Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.950.19.0508.01




9.5 Power spectral density
Test Method
This procedure shall be used if maximum peak conducted output power was used to
demonstrate compliance:
   1. The RF output of EUT was connected to the test receiver by RF cable. The path loss was
       compensated to the results for each measurement.
   2. Set analyzer center frequency to DTS channel center frequency. RBW=3kHz,
       VBW≥3RBW, Span=1.5 times DTS bandwidth, Detector=Peak, Sweep=auto,
       Trace= max hold.
   3. Allow trace to fully stabilize, use the peak marker function to determine the maximum
       amplitude level within the RBW .
   4. Repeat above procedures until other frequencies measured were completed.

Limit

                                                         Limit [dBm/3KHz]

                                                                ≤8

Test result
          Test Mode      Channel (MHz)                     Result (dBm/3KHz)              Limit(dBm/3KHz)            Verdict
              BLE                   2402                         -14.42                            8                     PASS
              BLE                   2440                         -13.77                            8                     PASS
              BLE                   2480                         -13.52                            8                     PASS

Test Graphs
                                                        BLE_BT4.0_Ant1_2402




                         D ate:6.M A Y .2019 16:30:13




EMC_SZ_FR_23.02 FCC                   TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                  Page 18 of 32
                         Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2017-06-20              Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.950.19.0508.01


                                                        BLE_BT4.0_Ant1_2440




                         D ate:6.M A Y .2019 16:32:56


                                                        BLE_BT4.0_Ant1_2480




                         D ate:6.M A Y .2019 16:34:55




EMC_SZ_FR_23.02 FCC                   TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                Page 19 of 32
                         Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2017-06-20              Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.950.19.0508.01




9.6 Spurious RF conducted emissions
Test Method
   1. The RF output of EUT was connected to the spectrum analyzer by RF cable. The path
      loss was compensated to the results for each measurement.
   2. Use the following spectrum analyzer settings:
      Span = wide enough to capture the peak level of the in-band emission and all spurious
      emissions (e.g., harmonics) from the lowest frequency generated in the EUT up through
      the 10th harmonic. Typically, several plots are required to cover this entire span.
      RBW = 100 kHz, VBW≥RBW, Sweep = auto, Detector function = peak, Trace = max hold
   3. Allow the trace to stabilize. Set the marker on the peak of any spurious emission
      recorded.
   4. The level displayed must comply with the limit specified in this Section. Submit these
      plots.
   5. Repeat above procedures until all frequencies measured were complete.

Limit

                                    Frequency Range                          Limit (dBc)
                                          MHz
                                        30-25000                                   -20




EMC_SZ_FR_23.02 FCC                   TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                Page 20 of 32
                         Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2017-06-20              Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.950.19.0508.01



Test Result
                                                        BLE_BT4.0_Ant1_2402_0~Reference




                         D ate:6.M A Y .2019 16:31:22


                                                         BLE_BT4.0_Ant1_2402_30~1000




                         D ate:6.M A Y .2019 16:31:30




EMC_SZ_FR_23.02 FCC                   TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                Page 21 of 32
                         Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2017-06-20              Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.950.19.0508.01


                                                        BLE_BT4.0_Ant1_2402_1000~26500




                         D ate:6.M A Y .2019 16:31:42


                                                        BLE_BT4.0_Ant1_2440_0~Reference




                         D ate:6.M A Y .2019 16:33:02


                                                         BLE_BT4.0_Ant1_2440_30~1000




                         D ate:6.M A Y .2019 16:33:11




EMC_SZ_FR_23.02 FCC                   TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                Page 22 of 32
                         Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2017-06-20              Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.950.19.0508.01


                                                        BLE_BT4.0_Ant1_2440_1000~26500




                         D ate:6.M A Y .2019 16:33:23


                                                        BLE_BT4.0_Ant1_2480_0~Reference




                         D ate:6.M A Y .2019 16:36:03


                                                         BLE_BT4.0_Ant1_2480_30~1000




                         D ate:6.M A Y .2019 16:36:12




EMC_SZ_FR_23.02 FCC                   TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                Page 23 of 32
                         Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2017-06-20              Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.950.19.0508.01


                                                        BLE_BT4.0_Ant1_2480_1000~26500




                         D ate:6.M A Y .2019 16:36:24




EMC_SZ_FR_23.02 FCC                   TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                Page 24 of 32
                         Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2017-06-20              Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.950.19.0508.01




9.7 Band edge
Test Method
   1. The RF output of EUT was connected to the spectrum analyzer by RF cable. The path
      loss was compensated to the results for each measurement.
   2. Use the following spectrum analyzer settings:
      Span = wide enough to capture the peak level of the in-band emission and all spurious
      RBW = 100 kHz, VBW≥RBW, Sweep = auto, Detector function = peak, Trace = max
      hold
   3. Allow the trace to stabilize, use the peak and delta measurement to record the result.
   4. The level displayed must comply with the limit specified in this Section.
   5. Repeat the test at the hopping off and hopping on mode, submit all the plots.


Limit:
According to §15.247(d), in any 100 kHz bandwidth outside the frequency bands in which the
spread spectrum intentional radiator in operating, the radio frequency power that is produced by
the intentional radiator shall be at least 20 dB below that in the 100 kHz bandwidth within the
band that contains the highest level of the desired power, based on either an RF conducted or a
radiated measurement, provided the transmitter demonstrates compliance with the peak
conducted power limits. In addition, radiated emissions which fall in the restricted bands, as
defined in §15.205(a), must also comply with the radiated emission limits specified in 15.209(a)
(see Section 15.205(c)).

                                    Frequency Range                          Limit (dBc)
                                          MHz
                                        30-25000                                   -20




EMC_SZ_FR_23.02 FCC                   TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                Page 25 of 32
                         Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2017-06-20              Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.950.19.0508.01


Test result
                                                        BLE_BT4.0_Ant1_Low_2402




                         D ate:6.M A Y .2019 16:30:23


                                                        BLE_BT4.0_Ant1_High_2480




                         D ate:6.M A Y .2019 16:35:05




EMC_SZ_FR_23.02 FCC                   TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                Page 26 of 32
                         Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2017-06-20              Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.950.19.0508.01




9.8 Spurious radiated emissions for transmitter

Test Method
   1. The EUT was place on a turn table which is 1.5m above ground plane for above 1GHz
      and 0.8m above ground for below 1GHz at 3meter chamber room for test. The table was
      rotated 360 degrees to determine the position of the highest radiation.
   2. Set to the maximum power setting and enable the EUT transmit continuously
   3. The EUT was set 3 meters away from the interference – receiving antenna, which was
      mounted on the top of a variable – height antenna tower.
   4. The height of antenna is varied from one meter to four meters above the ground to
      determine the maximum value of the field strength. Both horizontal and vertical
      polarizations of the antenna are set to make the measurement.
   5. For each suspected emission, the EUT was arranged to its worst case and then the
      antenna was tuned to heights from 1 meter to 4 meters and the rotatable table was
      turned
   6. Use the following spectrum analyzer settings According to C63.10:
      For Above 1GHz
      Span = wide enough to capture the peak level of the in-band emission and all spurious
      RBW = 1MHz, VBW≥RBW for peak measurement and VBW = 10Hz for average
      measurement, Sweep = auto, Detector function = peak, Trace = max hold.
      For Below 1GHz
      Use the following spectrum analyzer settings:
      Span = wide enough to capture the peak level of the in-band emission and all spurious
      RBW = 100 KHz, VBW≥RBW for peak measurement, Sweep = auto, Detector function =
      peak, Trace = max hold.
   7. Repeat above procedures until all frequencies measured were complete.


Note:
        1. The resolution bandwidth and video bandwidth of test receiver/spectrum analyzer is
        120 KHz for Quasi-peak detection (QP) at frequency below 1GHz.
        2. The resolution bandwidth of test receiver/spectrum analyzer is 1MHz and the video
        bandwidth is 3MHz for peak detection (PK) at frequency above 1GHz.
        3. The resolution bandwidth of test receiver/spectrum analyzer is 1MHz and the video
        bandwidth is 3MHz for RMS Average ((duty cycle ˂ 98%) for Average detection (AV) at
        frequency above 1GHz, then the measurement results was added to a correction factor
        (20log(1/duty cycle)).
        4. The resolution bandwidth of test receiver/spectrum analyzer is 1MHz and the video
        bandwidth is 10Hz (duty cycle ˃ 98%) for Average detection (AV) at frequency above
        1GHz.




EMC_SZ_FR_23.02 FCC                   TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                Page 27 of 32
                         Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2017-06-20              Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.950.19.0508.01




Limit

The radio emission outside the operating frequency band shall be at least 20 dB below that in
the 100 kHz bandwidth within the band that contains the highest level of the desired power.
Radiated emissions which fall in the restricted bands, as defined in section15.205, must comply
with the radiated emission limits specified in section 15.209.

              Frequency                 Field Strength                 Field Strength                       Detector
                 MHz                         uV/m                         dBμV/m
                 30-88                        100                            40                                 QP
                88-216                        150                           43.5                                QP
                216-960                       200                            46                                 QP
               960-1000                       500                            54                                 QP
              Above 1000                      500                            54                                 AV
              Above 1000                     5000                            74                                 PK




EMC_SZ_FR_23.02 FCC                     TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                Page 28 of 32
                           Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2017-06-20                Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.950.19.0508.01



Spurious radiated emissions for transmitter

According to C63.10, if the peak (or quasi-peak) measured value complies with the average limit,
it is unnecessary to perform an average measurement, so AV emission value did not show in
below table if the peak value complies with average limit.

Transmitting spurious emission test result as below:
2402MHz (30MHz – 1GHz)
Frequency      Read          Emission           Polarization            Limit          Margin        Detector            Corr.   Result
               level          Level
   MHz        dBuV/m         dBuV/m                                  dBμV/m              dB                               dB
  889.85       50.74          35.04              Horizontal           46.00            10.96            QP               -15.7    Pass
  36.25        60.19          33.39               Vertical            40.00             6.61            QP               -26.8    Pass

2402MHz (Above 1GHz)
Frequency      Read          Emission           Polarization           Limit           Margin        Detector            Corr.    Result
               level          Level
   MHz        dBuV/m         dBuV/m                                  dBμV/m             dB                               dB/m
*17774.53      28.77          50.07              Horizontal           74.00            23.93             PK              21.3     Pass
17513.44       28.80          49.80               Vertical            74.00            24.20             PK              21.0     Pass

2440MHz (30MHz – 1GHz)
Frequency      Read          Emission           Polarization            Limit          Margin        Detector            Corr.   Result
               level          Level
   MHz        dBuV/m         dBuV/m                                  dBμV/m              dB                               dB
    --                          --               Horizontal            --                --             QP                 --     Pass
    --                          --                Vertical             --                --             QP                 --     Pass

2440MHz (Above 1GHz)
Frequency      Read          Emission           Polarization            Limit         Margin         Detector        Corr.       Result
               level          Level
   MHz        dBuV/m         dBuV/m                                  dBμV/m             dB                           dB/m
17606.72       28.56          49.76              Horizontal           74.00            24.24            PK           21.2         Pass
*17914.69      28.63          50.13               Vertical            74.00            23.87            PK           21.5         Pass

2480MHz (30MHz – 1GHz)
Frequency      Read          Emission           Polarization            Limit          Margin        Detector            Corr.   Result
               level          Level
   MHz        dBuV/m         dBuV/m                                  dBμV/m              dB                               dB
    --                          --               Horizontal            --                --             QP                 --     Pass
    --                          --                Vertical             --                --             QP                 --     Pass

2480MHz (Above 1GHz)
Frequency      Read          Emission           Polarization            Limit         Margin         Detector        Corr.       Result
               level          Level
   MHz        dBuV/m         dBuV/m                                  dBμV/m             dB                           dB/m
17665.31       28.75          49.95              Horizontal           74.00            24.05            PK           21.2         Pass
*17819.06      28.12          49.52               Vertical            74.00            24.48            PK           21.4         Pass




EMC_SZ_FR_23.02 FCC                   TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                   Page 29 of 32
                         Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2017-06-20              Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.950.19.0508.01




Remark:
      (1) “*” means the emission(s) appear within the restrict bands shall follow the requirement of section
          15.205.
      (2) Data of measurement within this frequency range shown “--” in the table above means the reading of
          emissions are the noise floor or attenuated more than 20dB below the permissible limits or the field
          strength is too small to be measured.
      (3) Level= Reading Level + Correction Factor
      (4) Correction factor = Antenna Factor + Cable Loss- Amplifier Gain.
          (The Reading Level is recorded by software which is not shown in the sheet)




EMC_SZ_FR_23.02 FCC                     TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                Page 30 of 32
                           Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2017-06-20                Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.950.19.0508.01



10 Test Equipment List
Conducted Emission Test
      Description         Manufacturer                   Model no.                    Serial no.                   cal. due date
   EMI Test Receiver    Rohde & Schwarz                   ESR 3                        101782                        2019-7-6
         LISN           Rohde & Schwarz                  ENV4200                       100249                        2019-7-6
      Attenuator       Shanghai Huaxiang                 TS2-26-3                    080928189                       2019-7-6
     Test software      Rohde & Schwarz                   EMC32                     Version9.15.00                      N/A

Radiated Emission Test
         DESCRIPTION             MANUFACTURER                    MODEL NO.               SERIAL NO.             CAL. DUE DATE
        EMI Test Receiver        Rohde & Schwarz                  ESR 26                   101269                  2019-7-6
  Trilog Super Broadband Test
                                     Schwarzbeck                 VULB 9163                     707                   2019-6-28
            Antenna
          Horn Antenna             Rohde & Schwarz                   HF907                  102295                   2019-6-28
                                                                QWH-SL-18-
    Wideband Horn Antenna                Q-PAR                                               12827                   2019-7-12
                                                                 40-K-SG
        Loop Antenna               Rohde & Schwarz               HFH2-Z2                   100398                        2019-7-6
         Pre-amplifier             Rohde & Schwarz               SCU 18                    102230                        2019-7-6
       Signal Generator            Rohde & Schwarz                SMY01                 839369/005                       2019-7-6
          Attenuator                   Agilent                    8491A                 MY39264334                       2019-7-6
   3m Semi-anechoic chamber             TDK                       9X6X6                      ----                        2020-7-7
        Test software              Rohde & Schwarz                EMC32                Version 9.15.00                     N/A

RF conducted test
    DESCRIPTION        MANUFACTURER                 MODEL NO.                       SERIAL NO.                  CAL. DUE DATE
    Signal Analyzer    Rohde & Schwarz                FSV40                           101030                       2019-7-6
   RF Switch Module    Rohde & Schwarz            OSP120/OSP-B157                  101226/100851                   2019-7-6
     Power Splitter       Weinschel                    1580                            SC319                       2019-7-5
     Test software          Tonscend               System for BT/WIFI                 Version 2.6                          N/A




EMC_SZ_FR_23.02 FCC                   TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                  Page 31 of 32
                         Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2017-06-20              Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.950.19.0508.01



11 System Measurement Uncertainty

For a 95% confidence level, the measurement expanded uncertainties for defined systems, in
accordance with the recommendations of ISO 17025 were:

                                   System Measurement Uncertainty
                        Test Items                                 Extended Uncertainty
  Uncertainty for Conducted Emission 150kHz-30MHz      3.21dB
  (for test using AMN ENV432 or ENV4200)
  Uncertainty for Radiated Spurious Emission 25MHz-    Horizontal: 4.91dB;
  3000MHz                                              Vertical: 4.89dB;
  Uncertainty for Radiated Spurious Emission 3000MHz- Horizontal: 4.80dB;
  18000MHz                                             Vertical: 4.79dB;
  Uncertainty for Radiated Spurious Emission           Horizontal: 5.05dB;
  18000MHz-40000MHz                                    Vertical: 5.04dB;
                                                       RF Power Conducted: 1.16dB
  Uncertainty for Conducted RF test with TS 8997
                                                       Frequency test involved: 0.6×10-7 or 1%




EMC_SZ_FR_23.02 FCC                   TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                Page 32 of 32
                         Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2017-06-20              Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299



Document Created: 2019-06-11 10:42:21
Document Modified: 2019-06-11 10:42:21

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC