RF Exposure

FCC ID: CNFKWST1

RF Exposure Info

Download: PDF
FCCID_3145717

GoPro, Inc.                                                               FCC ID: CNFKWST1, IC: 10193A-KWST1


5     FCC §2.1091 & §15.247(i) & ISED RSS-102 - RF Exposure

5.1    Applicable Standards
According to FCC §15.247(i) and §1.1307(b)(1), systems operating under the provisions of this section shall be
operated in a manner that ensures that the public is not exposed to radio frequency energy level in excess of the
Commission’s guidelines.

                              Limits for General Population/Uncontrolled Exposure

         Frequency          Electric Field        Magnetic Field
                                                                       Power Density        Averaging Time
           Range              Strength              Strength
                                                                         (mW/cm2)             (minutes)
           (MHz)                (V/m)                (A/m)
                                 Limits for General Population/Uncontrolled Exposure
          0.3-1.34               614                   1.63                * (100)                 30
                                                                                   2
              1.34-30           824/f                 2.19/f              * (180/f )               30
              30-300             27.5                 0.073                  0.2                   30
          300-1500                 /                    /                  f/1500                  30
        1500-100,000               /                    /                    1.0                   30

        f = frequency in MHz
        * = Plane-wave equivalent power density
Before equipment certification is granted, the procedure of IC RSS-102 must be followed concerning the
exposure of humans to RF field


According to ISED RSS-102 Issue 5 §2.5.2

RF exposure evaluation is required if the separation distance between the user and/or bystander and the
device’s radiating element is greater than 20 cm, except when the device operates as follows:

• below 20 MHz6 and the source-based, time-averaged maximum e.i.r.p. of the device is equal to or less
  than 1 W (adjusted for tune-up tolerance);

• at or above 20 MHz and below 48 MHz and the source-based, time-averaged maximum e.i.r.p. of the
   device is equal to or less than 4.49/ƒ0.5 W (adjusted for tune-up tolerance), where ƒ is in MHz;

• at or above 48 MHz and below 300 MHz and the source-based, time-averaged maximum e.i.r.p. of the
   device is equal to or less than 0.6 W (adjusted for tune-up tolerance);

• at or above 300 MHz and below 6 GHz and the source-based, time-averaged maximum e.i.r.p. of the
   device is equal to or less than 1.31 x 10-2 ƒ0.6834 W (adjusted for tune-up tolerance), where ƒ is in MHz;

• at or above 6 GHz and the source-based, time-averaged maximum e.i.r.p. of the device is equal to or
   less than 5 W (adjusted for tune-up tolerance).

In these cases, the information contained in the RF exposure technical brief may be limited to information that
demonstrates how the e.i.r.p. was derived.




Report Number: R1605031-247                  Page 14 of 79                  FCC Part 15C/ISED RSS-247 Test Report


GoPro, Inc.                                                                      FCC ID: CNFKWST1, IC: 10193A-KWST1

5.2    MPE Prediction
Predication of MPE limit at a given distance, Equation from OET Bulletin 65, Edition 97-01

                                                        S = PG/4R²
Where: S = power density
       P = power input to antenna
       G = power gain of the antenna in the direction of interest relative to an isotropic radiator
       R = distance to the center of radiation of the antenna


5.3    MPE Results

                                     Maximum output power at antenna input terminal (dBm):            22.87
                                      Maximum output power at antenna input terminal (mW):            193.6
                                                                      Prediction distance (cm):       20
                                                                 Prediction frequency (MHz):          2412
                                                      Maximum Antenna Gain, typical (dBi):            4
                                                          Maximum Antenna Gain (numeric):             2.512
                                 Power density of prediction frequency at 20.0 cm (mW/cm2):           0.097
                   FCC MPE limit for uncontrolled exposure at prediction frequency (mW/cm2):          1.0


The device is compliant with the requirement MPE limit for uncontrolled exposure. The maximum power
density at the distance of 20 cm is 0.097mW/cm2, limit is 1.0mW/cm2.


5.4    ISED Routine RF Exposure Exemption
The max tune-up peak conducted output power is 22.87 dBm at 2412 MHz and the antenna gain is 4 dBi, so the
e.i.r.p is 26.87 dBm (0.486 W).

Exemption from Routine Evaluation Limit is:
          -2   0.6834             -2        0.6834
1.31 x 10 ƒ             = 1.31 x 10 x 2412           = 2.68 > 0.486

So the device is compliance exemption from Routine Evaluation Limits –RF exposure Evaluation.