LRM2 Radio Module – Host Interface Specification                                              LRM2 Configuration Concept
Document p/n: 9S02-8969-A001 Rev.A




5.              LRM2 Configuration Concept

All LRM2 configuration and status parameters are accessible through addressable registers.
-     All parameters can be read and written only in CONFIG mode.
The definition of the configuration registers is given in reference [3]. This section addresses the basic description of
all these three methods.

5.1          Console Interface
    The serial interface configuration port is enabled by asserting !CONFIG signal; the serial interface is automatically
    reconfigured in asynchronous mode, running at 38400bps, 8N1. All ASCII strings received are interpreted as
    configuration commands. This mode is particularly useful for stand-alone testing, when the unit can be controlled
    from a PC or by an operator/tester using a terminal emulation program.

    5.1.1 “Write” command
    wrCmd register value , where:
     wrCmd = write command. “w” or “wr” can be used and are equivalent
     register = register identification. Can use the register name or register address
     value    = value to be written, in decimal or hexadecimal format. Hexadecimal values are preceded by ‘0x’


    Examples:
    wr txf 915000000             :Write 915000000 to register txf (Tx frequency)
    wr 0x80 18                   :Write 18 to register address 0x80
    wr txf 915000000 0x80 18 :Concatenate the two writes above in a single instruction


    Here is the command to set the transmit output power level in range 0dBm to 20dBm
    wr txp 20           :the radio transmit power is 20+/-1.0dBm (maximum)
    wr txp 10           : the radio transmit power is 10+/-1.0dBm (mid power level)
    wr txp 0            : the radio transmit power is 0+/-1.0dBm (minimum)



    5.1.2 “Read” command
    rdCmd reg where:
    rdCmd= read command. r or rd can be used and are equivalent
    reg      = register identification. Can use the register name or register address


    Examples:
    rd txf            : Reads register txf (Tx frequency)
    rd 0x80           : Reads register address 0x80
    rd txf 0x80       : Reads registers txf and 0x80 in a single instruction