Z-wave report revised

FCC ID: CFS8DLWFZW

Test Report

Download: PDF
FCCID_3922423

FCC / ISED Test Report

                For

         ADTZWM
          Report #: 50346-M2

       FCC ID: CFS8DLWFZW
         IC ID: 573F-WFZW



 Report Completion Date: 2018-07-09

          Prepared by and for:
      Honeywell International Inc.
        2 Corporate Center Dr.
        Suite 100 PO Box 9040
          Melville, NY 11747




       Testing
       NVLAP Lab Code: 600110


Report #: 50346-M2                                                                                Date: 2018-07-09
FCC ID: CFS8DLWFZW                                                                             IC ID: 573F-WFZW



                                             Document Introduction



Honeywell tested the above equipment in accordance with the requirements set forth in the listed
standards. All indications of Pass/Fail in the report are opinions expressed by Honeywell based
on interpretations and/or observations of test results. Measurement Uncertainties were not taken
into account and are published for informational purposes only. The test results show that the
equipment tested is capable of demonstrating compliance with the requirements as documented
in this report.

This document is a record of the FCC/ISED Test Report for Honeywell products. It demonstrates
the data required to be analyzed to certify a product according to the requirements of the FCC &
ISED.

The results in the report reflect only the model of the items under test unless noted otherwise.
This document may not be altered or revised in any way unless done so my Honeywell and all
revisions are duly noted in the revisions section. Any alterations of this document not carried out
by Honeywell will constitute fraud and shall nullify the document. This report must not be used
by the client to claim product certification, approval or endorsement by NVLAP, NIST, any
agency of the Federal Government, or any agency of any government.



                                        Test Report Revision History
 Revision          Prepared By          Reviewed By          Revision Detail                         Release Date
       ---         M. Antola            A. Roussin           Original Release                        2018-06-29

       A           M. Antola            A. Roussin           Updated 20dB BW section;                2018-07-09
                                                             updated equipment lists




                                                        Page 2 of 23
Honeywell International                                                                  Document #: 800-23065, Revision A
2 Corporate Center Dr., Melville, NY 11747                                                              TEL: (516) 577-2000
        This report shall not be reproduced except in full, without the written approval of Honeywell International


Report #: 50346-M2                                                                                Date: 2018-07-09
FCC ID: CFS8DLWFZW                                                                             IC ID: 573F-WFZW




                                            Report Authorization


 Report Prepared By:                                                                 Reviewed & Approved By:




 Michael Antola                                                                                 Andrew Roussin
 Hardware Engineer                                                                        Hardware Engineer II
 HBT RF & EMC Design                                                                    HBT RF & EMC Design
 Honeywell International Inc.                                                        Honeywell International Inc.




                                                        Page 3 of 23
Honeywell International                                                                  Document #: 800-23065, Revision A
2 Corporate Center Dr., Melville, NY 11747                                                              TEL: (516) 577-2000
        This report shall not be reproduced except in full, without the written approval of Honeywell International


Report #: 50346-M2                                                                                                                       Date: 2018-07-09
FCC ID: CFS8DLWFZW                                                                                                                    IC ID: 573F-WFZW




Contents
Applicable Test Standards/Limits..................................................................................................................................5
Deviations from Test Methods ......................................................................................................................................5
Facilities and Accreditation ...........................................................................................................................................5
Test Item Description ....................................................................................................................................................5
Worse-Case Configuration / Mode & Block Diagram...................................................................................................6
Calibration & Measurement Uncertainty .......................................................................................................................7
Opinions / Interpretations ..............................................................................................................................................7
Test Summary ................................................................................................................................................................8
  20dB Emission Bandwidth ........................................................................................................................................9
  99% Occupied Bandwidth ....................................................................................................................................... 11
  Radiated Emissions (Intentional) ............................................................................................................................ 13
  Conducted Emissions (Mains)................................................................................................................................. 21
END OF REPORT....................................................................................................................................................... 23




                                                        Page 4 of 23
Honeywell International                                                                  Document #: 800-23065, Revision A
2 Corporate Center Dr., Melville, NY 11747                                                              TEL: (516) 577-2000
        This report shall not be reproduced except in full, without the written approval of Honeywell International


Report #: 50346-M2                                                                                Date: 2018-07-09
FCC ID: CFS8DLWFZW                                                                             IC ID: 573F-WFZW



                                   Applicable Test Standards/Limits
            Test Standards/Limits                                 Result                    Dates Tested
 ANSI C63.10: 2013                                               Compliant               04/25/18 – 06/29/18
 RSS-210, Issue 9, Annex B.10                                    Compliant               04/25/18 – 06/29/18
 RSS-GEN, Issue 4                                                Compliant               04/25/18 – 06/29/18
 CFR 47 Pt 15 Subpart C, Section 15.207/209                      Compliant               04/25/18 – 06/29/18
 CFR 47 Pt 15 Subpart C, Section 15.249                          Compliant               04/25/18 – 06/29/18

                                     Deviations from Test Methods
   #     Deviation Description
 0       None

                                       Facilities and Accreditation
 The test site and measurement facility used to collect data are located at 2 Corporate Center
 Dr., Melville, NY 11747, USA. Honeywell International is accredited by NVLAP, Laboratory
 Code 600110-0. The full scope of accreditation can be viewed at the NVLAP website.



                                            Test Item Description
 The ADTZWM communication module is intended to provide compatible control panels with
 a Wi-Fi connection as well as connection with the and the ability to control Z-Wave device.
 The module connects directly to the control panel and is powered via the control panel’s
 connection. Thus, this module will be certified for full modular approval.

 The module utilizes discrete off-the-shelf Wi-Fi and Z-Wave chips incorporated onto the host
 board. The Z-Wave contains a single integral trace antenna, with a gain of 2.46dBi. This
 report covers the testing required for Z-Wave only, Wi-Fi testing will be cover as part of a
 separate report.




                                                        Page 5 of 23
Honeywell International                                                                  Document #: 800-23065, Revision A
2 Corporate Center Dr., Melville, NY 11747                                                              TEL: (516) 577-2000
        This report shall not be reproduced except in full, without the written approval of Honeywell International


Report #: 50346-M2                                                                                Date: 2018-07-09
FCC ID: CFS8DLWFZW                                                                             IC ID: 573F-WFZW



                    Worse-Case Configuration / Mode & Block Diagram
 Radiated emissions was performed with the EUT set to transmit at the low/high channels with
 the highest output power as worst-case scenario. The EUT was investigated in all three
 orthogonal planes to determine the worst-case emissions. It was determined that the Y axis
 (lying flat) orientation was the worst-case orientation. Therefore, all final radiated test was
 performed with the EUT in the Y axis orientation. See setup photos for details.



                                                                                         Power
                                  EUT                 Host Board
                                                                                        Adapter




                                                        Cable
                                                        Serial
                                                        USB/



                                                         Laptop




                                                     120Vac/60Hz




                                        Test Sample Identification
       Sample ID Number                        Sample Serial Number                               Date Received
           MEL-461                           Non-serialized production unit                        04/02/2018
           MEL-462                           Non-serialized production unit                        04/02/2018
           MEL-469                           Non-serialized production unit                        04/02/2018




                                                        Page 6 of 23
Honeywell International                                                                  Document #: 800-23065, Revision A
2 Corporate Center Dr., Melville, NY 11747                                                              TEL: (516) 577-2000
        This report shall not be reproduced except in full, without the written approval of Honeywell International


Report #: 50346-M2                                                                                Date: 2018-07-09
FCC ID: CFS8DLWFZW                                                                             IC ID: 573F-WFZW

Calibration & Measurement Uncertainty

          •    Measuring Instrument Calibration – The measuring equipment utilized to perform
               the tests documented in this report have been calibrated in accordance with the
               manufacturer’s recommendations and is traceable to recognized national standards.

          •    Sample Calculation – Where relevant, the following sample calculation is provided:

               Field Strength (dBuV/m) = Measured Voltage (dBuV) + Antenna Factor (dB/m) +
               Cable Loss (dB) – Preamp Gain (dB)

               [i.e.] 37 dBuV/m = 30 dBuV + 18.5 dB/m + 0.5 dB – 12 dB

          •    Uncertainty - Figures are valid to a confidence level of 95%.

                              Test                                                Standard Uncertainty
       Radiated Emissions (30-200MHz Horizontal)                                       +/- 5.05 dB
       Radiated Emissions (30-200MHz Vertical)                                         +/- 5.28 dB
       Radiated Emissions (200-1000MHz Horizontal)                                    +/- 10.21 dB
       Radiated Emissions (200-1000MHz Vertical)                                      +/- 10.36 dB
       Radiated Emissions (Above 1GHz)                                                 +/- 9.70 dB
       Conducted Emissions (150KHz-30MHz)                                              +/- 4.36 dB


Opinions / Interpretations

 None




                                                        Page 7 of 23
Honeywell International                                                                  Document #: 800-23065, Revision A
2 Corporate Center Dr., Melville, NY 11747                                                              TEL: (516) 577-2000
        This report shall not be reproduced except in full, without the written approval of Honeywell International


Report #: 50346-M2                                                                                Date: 2018-07-09
FCC ID: CFS8DLWFZW                                                                             IC ID: 573F-WFZW




                                                 Test Summary
 All tests described below are required, unless otherwise noted. Notes should be described in detail in the
 “Additional notes” section.
    #                                       Test Description                                           Status
    1       99% Occupied Bandwidth                                                                      PASS
    2       20 dB Emission Bandwidth                                                                    PASS
    3       Radiated Emissions (Intentional)                                                            PASS
    4       Conducted Emissions (Mains)                                                                 PASS




                                                        Page 8 of 23
Honeywell International                                                                  Document #: 800-23065, Revision A
2 Corporate Center Dr., Melville, NY 11747                                                              TEL: (516) 577-2000
        This report shall not be reproduced except in full, without the written approval of Honeywell International


Report #: 50346-M2                                                                                 Date: 2018-07-09
FCC ID: CFS8DLWFZW                                                                              IC ID: 573F-WFZW


20dB Emission Bandwidth

Test Description
Measure the maximum width of the emission that is constrained by the frequencies associated with the two
outermost amplitude points (upper and lower frequencies) that are attenuated by 20 dB relative to the maximum
level measured in the fundamental emission.

Test Criteria

                                 Reference                                  Limit
                           CFR 47 Subpart C 15.249                  None- For reporting only

Test Information

                                                     Temperature       Humidity      Pressure
          Tester    Test Location         Date                                                    Results (P/F)
                                                        (ºC)            (%RH)         (mbar)
           MA           RF Lab        06/25/2018        22.6             37.2          1014             P

Equipment List

   Instrument Type           ID #      Serial #           Manufacturer         Model        Cal Date        Cal Due Date
   Spectrum Analyzer        11549     MY46187211             Agilent           E4440A       06/06/17          06/06/19
       Attenuator              -        1624                Pasternack        PE7087-6        NA                 NA
  Environmental Meter       11533      A070144               Extech            SD700        08/21/17          08/21/20
                                                           Instruments


Test Results
                         Frequency           20dB Bandwidth             Limit (kHz)           Margin (MHz)
         Channel
                           (MHz)                (in kHz)
           Low             908.42                105.89                     2271                    -2.17
           High             916                   85.55                     2290                    -2.20




                                                        Page 9 of 23
Honeywell International                                                                  Document #: 800-23065, Revision A
2 Corporate Center Dr., Melville, NY 11747                                                              TEL: (516) 577-2000
        This report shall not be reproduced except in full, without the written approval of Honeywell International


Report #: 50346-M2                                                                                Date: 2018-07-09
FCC ID: CFS8DLWFZW                                                                             IC ID: 573F-WFZW

20dB Bandwidth




                                                   Low Channel - Plot




                                                  High Channel - Plot




                                                       Page 10 of 23
Honeywell International                                                                  Document #: 800-23065, Revision A
2 Corporate Center Dr., Melville, NY 11747                                                              TEL: (516) 577-2000
        This report shall not be reproduced except in full, without the written approval of Honeywell International


Report #: 50346-M2                                                                                 Date: 2018-07-09
FCC ID: CFS8DLWFZW                                                                              IC ID: 573F-WFZW


99% Occupied Bandwidth

Test Description
The emission bandwidth (x dB) is defined as the frequency range between two points, one above and one below the
carrier frequency, at which the spectral density of the emission is attenuated x dB below the maximum in-band
spectral density of the modulated signal. Spectral density (power per unit bandwidth) is to be measured with a
detector of resolution bandwidth in the range of 1% to 5% of the anticipated emission bandwidth, and a video
bandwidth at least 3x the resolution bandwidth.
When the occupied bandwidth limit is not stated in the applicable RSS or reference measurement method, the
transmitted signal bandwidth shall be reported as the 99% emission bandwidth, as calculated or measured.

Test Criteria

                                        Reference                            Limit
                                    RSS-GEN, Section 6.6                      N/A

Test Information

                                                     Temperature       Humidity      Pressure
          Tester    Test Location         Date                                                    Results (P/F)
                                                        (ºC)            (%RH)         (mbar)
           MA           RF Lab        06/25/2018        22.6             37.2          1014             P

Equipment List

    Instrument Type          ID #      Serial #         Manufacturer            Model       Cal Date    Cal Due Date
    Spectrum Analyzer       11549     MY46187211            Agilent            E4440A       06/06/17      06/06/19
        Attenuator             -        1624               Pasternack         PE7087-6        NA             NA
   Environmental Meter      11533      A070144         Extech Instruments      SD700        08/21/17      08/21/20


Test Results
                             Channel      Frequency (MHz)       99% Bandwidth (in kHz)
                               Low               908.42                   82.6679
                               High               916                     90.3657




                                                       Page 11 of 23
Honeywell International                                                                  Document #: 800-23065, Revision A
2 Corporate Center Dr., Melville, NY 11747                                                              TEL: (516) 577-2000
        This report shall not be reproduced except in full, without the written approval of Honeywell International


Report #: 50346-M2                                                                                Date: 2018-07-09
FCC ID: CFS8DLWFZW                                                                             IC ID: 573F-WFZW

99% Occupied Bandwidth




                                                   Low Channel - Plot




                                                  High Channel - Plot




                                                       Page 12 of 23
Honeywell International                                                                  Document #: 800-23065, Revision A
2 Corporate Center Dr., Melville, NY 11747                                                              TEL: (516) 577-2000
        This report shall not be reproduced except in full, without the written approval of Honeywell International


Report #: 50346-M2                                                                                Date: 2018-07-09
FCC ID: CFS8DLWFZW                                                                             IC ID: 573F-WFZW


Radiated Emissions (Intentional)

Test Description
Intentional Radiator Radiated Emissions are a test of the emissions, and harmonics on the EUT. The EUT is
positioned to get the maximum emissions after a series of prescan measurements.
The EUT is placed on a non-conducting table 80 cm above the ground plane for below 1 GHz measurements and 1.5
m above the ground plane for above 1 GHz measurements. The antenna to EUT distance is 3 meters.
For measurements below 1 GHz the resolution bandwidth is set to 120 kHz for peak detection measurements or 120
kHz for quasi-peak detection measurements. Peak detection is used unless otherwise noted as quasi-peak.
For measurements above 1 GHz the resolution bandwidth is set to 1 MHz; the video bandwidth is set to 1 MHz for
peak measurements and as applicable for average measurements.
The spectrum from 30 MHz to 10 GHz is investigated with the transmitter set to the lowest, middle, and highest
channels in each applicable band.
The EUT is rotated through 360 degrees to maximize emissions received. The antenna is scanned from 1 to 4 meters
above the ground plane to further maximize the emission. Measurements are made with the antenna polarized in
both the vertical and the horizontal positions.

Test Criteria

          Reference                                                       Limit
                                                                Field strength of                Field strength of
                                     Fundamental
                                                                  fundamental                       harmonics
                                      Frequency
 CFR 47 Subpart C, 15.249                                            (uV/m)                           (uV/m)
   RSS-210, Annex B                  902-928MHz                         50                              500
                                   2400-2483.5MHz                       50                              500
                                    5725-5875MHz                        50                              500
                                    24.0-24.25GHz                      250                             2500

Test Information

                                                            Temperature       Humidity      Pressure
   Tester       Test Location               Date                                                        Results (P/F)
                                                               (ºC)            (%RH)         (mbar)
   CL/JB     RF Chamber/OATS         05/15/18-06/28/18         28.3              54           1002             P



NOTE: Below 30MHz, pretesting showed that no emissions as a product of the EUT were detected within 20dB of
the regulatory limit. Prescans performed in an anechoic chamber, final measurements performed on an OATS.

Since both Wi-Fi and Z-Wave radio can transmit simultaneously, additional spurious scans are provided with both
radios on and transmitting in their worse-case state.




                                                       Page 13 of 23
Honeywell International                                                                  Document #: 800-23065, Revision A
2 Corporate Center Dr., Melville, NY 11747                                                              TEL: (516) 577-2000
        This report shall not be reproduced except in full, without the written approval of Honeywell International


Report #: 50346-M2                                                                                Date: 2018-07-09
FCC ID: CFS8DLWFZW                                                                             IC ID: 573F-WFZW

Equipment List

    Instrument Type          ID #      Serial #        Manufacturer                Model             Cal       Cal Due
                                                                                                     Date       Date
 RF Chamber
       Spectrum             11496       100303       Rohde & Schwarz              FSU26            04/11/18    04/11/19
        Analyzer
     Loop Antenna           11535       121080           Com-Power               AL-130R           10/17/18    10/17/19
    (9kHz-30MHz)
     Bilog Antenna          11311      A022406              Sunol                   JB5            02/01/18    02/01/19
   (30MHz-5GHz)
     Horn Antenna            2319        2317              EMCO                    3115            01/10/18    01/10/19
      (1-18GHz)
         Preamp             11537      1603006          Mini Circuits          TVA-11-422            N/A          N/A
    (10-4200MHz)
         Preamp             11557     18040034           Com-Power              PAM-118A             N/A          N/A
      (1-18GHz)
      Band Reject           11553        G041           Micro-tronics         BRM50702-01            N/A          N/A
          Filter
     Measurement            11543      Version               UL                  UL EMC              N/A          N/A
        Software                         9.5
       RF Cable               -           -             Mini-Circuits             RDE#2              N/A         N/A
       RF Cable               -           -            Insulated Wire             SMA#8              N/A         N/A
    Environmental           11533      A070144       Extech Instruments           SD700            08/21/17    08/21/20
          Meter
 OATS
       Spectrum             11545       103125       Rohde & Schwarz              FSW26            02/21/18    02/21/19
        Analyzer
     Bilog Antenna          11534      A012816              Sunol                   JB6            03/27/18    03/27/19
   (30MHz-6GHz)
     Horn Antenna            2973        3127              EMCO                   RGA-60           01/22/18    01/22/19
      (1-18GHz)
         Preamp             11538     233701631         Mini Circuits          ZVA-213-S+            N/A          N/A
  (800MHz-21GHz)
   High Pass Filter         11552       G018            Micro-tronics         HPM50111-01            N/A          N/A
     Measurement            11543      Version              UL                  UL EMC               N/A          N/A
        Software                         9.5
       RF Cable               -           -              Pasternack             RDE#1                N/A         N/A
       RF Cable               -           -             MegaPhase            EMC2-S1S1-360           N/A         N/A
    Environmental           11533      A070144       Extech Instruments         SD700              08/21/17    08/21/20
          Meter




                                                       Page 14 of 23
Honeywell International                                                                  Document #: 800-23065, Revision A
2 Corporate Center Dr., Melville, NY 11747                                                              TEL: (516) 577-2000
        This report shall not be reproduced except in full, without the written approval of Honeywell International


Report #: 50346-M2                                                                                      Date: 2018-07-09
FCC ID: CFS8DLWFZW                                                                                   IC ID: 573F-WFZW

Test Results

Spurious Emissions

Below 1GHz




                                                     Low Channel - Plot


  Frequency     Meter    Det   AF_JB6 [dB/m]   Cable 1 [dB]   Corrected   Limit (dBuV/m)   Margin   Azimuth   Height   Polarity
    (MHz)      Reading                                         Reading                      (dB)     (Degs)    (cm)
               (dBuV)                                         (dBuV/m)
   30.3296     10.85     Qp        24.6            .9          36.35           40           -3.65    169       293        H
    55.536     14.89     Qp         12             1.1         27.99           40          -12.01    227       364        H
   30.2018     11.03     Qp        24.7            .9          36.63           40           -3.37    218       351        V
   54.8694     19.14     Qp        12.1            1.1         32.34           40           -7.66     37       196        V
 * 281.1903    4.55      Qp        17.6             3          25.15          46.02        -20.87     62       310        H
 * 282.0764    4.94      Qp        17.6             3          25.54          46.02        -20.48     50       321        V
  908.1465     35.88     Pk        27.3            8.3         71.48           94          -22.52    296       102        H
  908.1415     30.12     Pk        27.3            8.3         65.72           94          -28.28    159       105        V

* - indicates frequency in CFR47 Pt 15 / IC RSS-Restricted Band
Pk - Peak detector
Qp - Quasi-Peak detector

                                                     Low Channel - Data




                                                       Page 15 of 23
Honeywell International                                                                  Document #: 800-23065, Revision A
2 Corporate Center Dr., Melville, NY 11747                                                              TEL: (516) 577-2000
        This report shall not be reproduced except in full, without the written approval of Honeywell International


Report #: 50346-M2                                                                                     Date: 2018-07-09
FCC ID: CFS8DLWFZW                                                                                  IC ID: 573F-WFZW




                                                    High Channel - Plot


  Frequency    Meter    Det   AF_JB6 [dB/m]   Cable 1 [dB]   Corrected   Limit (dBuV/m)   Margin   Azimuth   Height   Polarity
    (MHz)     Reading                                         Reading                      (dB)     (Degs)    (cm)
              (dBuV)                                         (dBuV/m)
   30.8771     10.9     Qp        24.2            .9            36            40             -4     146       280        H
   55.5194     14.91    Qp         12             1.1         28.01           40          -11.99     64       390        H
   30.2427     10.97    Qp        24.7            .9          36.57           40           -3.43    265       309        V
   55.0252     19.2     Qp        12.1            1.1          32.4           40            -7.6     41       204        V
 * 283.7238     4.3     Qp        17.6            3.1           25           46.02        -21.02    206       275        H
 * 279.7007    6.69     Qp        17.6             3          27.29          46.02        -18.73     38       182        V
   915.785     37.3     Pk        27.4            8.3           73            94            -21     290       103        H
    915.75     29.27    Pk        27.4            8.3         64.97           94          -29.03    157       167        V

* - indicates frequency in CFR47 Pt 15 / IC RSS-Restricted Band
Pk - Peak detector
Qp - Quasi-Peak detector

                                                   High Channel - Data




                                                       Page 16 of 23
Honeywell International                                                                  Document #: 800-23065, Revision A
2 Corporate Center Dr., Melville, NY 11747                                                              TEL: (516) 577-2000
        This report shall not be reproduced except in full, without the written approval of Honeywell International


Report #: 50346-M2                                                                                                       Date: 2018-07-09
FCC ID: CFS8DLWFZW                                                                                                    IC ID: 573F-WFZW


1-10GHz




                                                                Low Channel - Plot


 Frequency    Meter     Det     AF     SWBOX1   SMA7    SMA5     HPF    Corrected   Avg Limit   Margin   Peak Limit     PK     Azimuth   Height   Polarity
   (GHz)     Reading          [dB/m]     [dB]    [dB]    [dB]    [dB]    Reading    (dBuV/m)     (dB)    (dBuV/m)     Margin    (Degs)    (cm)
             (dBuV)                                                     (dBuV/m)                                       (dB)
  * 1.021    41.06     PK2    24.4      -40.2    1.7     1.6      -      28.56          -          -        74        -45.44    242       107        H
  * 1.021    31.87     MAv1   24.4      -40.2    1.7     1.6      -      19.37         54       -34.63       -           -      242       107        H
  * 9.04     38.62     PK2    37.7      -39.4    5.4      5      .1      47.42          -          -        74        -26.58    33        322        H
  * 9.044    27.12     MAv1   37.7      -39.4    5.4      5      .1      35.92         54       -18.08       -           -      33        322        H
   1.859     73.11     PK2    27.4      -42.4    2.3     2.2     .4      63.01          -          -        74        -10.99    132       315        V
   1.861     37.68     MAv1   27.5      -42.4    2.3     2.2     .4      27.68         54       -26.32       -           -      132       315        V
    2.5      52.26     PK2    28.7      -43.3    2.7     2.6     .3      43.26          -          -        74        -30.74    338       128        V
    2.5      49.09     MAv1   28.7      -43.3    2.7     2.6     .3      40.09         54       -13.91       -           -      338       128        V
  * 2.724    45.08     PK2     29       -43.6    2.8     2.7     .2      36.18          -          -        74        -37.82    15        155        V
  * 2.722    33.56     MAv1    29       -43.6    2.8     2.7     .2      24.66         54       -29.34       -           -      15        155        V
   6.361     40.76     PK2    34.8      -39.8    4.2     4.2     1.1     45.26          -          -        74        -28.74    180       205        V
    6.36     28.96     MAv1   34.8      -39.8    4.2     4.2     1.1     33.46         54       -20.54       -           -      180       205        V


* - indicates frequency in CFR47 Pt 15 / IC RSS-Restricted Band
PK2 - KDB558074 Method: Maximum Peak
MAv1 - KDB558074 Option 1 Maximum RMS Average

                                                                Low Channel - Data




                                                       Page 17 of 23
Honeywell International                                                                  Document #: 800-23065, Revision A
2 Corporate Center Dr., Melville, NY 11747                                                              TEL: (516) 577-2000
        This report shall not be reproduced except in full, without the written approval of Honeywell International


Report #: 50346-M2                                                                                                        Date: 2018-07-09
FCC ID: CFS8DLWFZW                                                                                                     IC ID: 573F-WFZW




                                                                High Channel - Plot


 Frequency    Meter     Det     AF     SWBOX1   SMA7    SMA5      HPF    Corrected   Avg Limit   Margin   Peak Limit     PK     Azimuth   Height   Polarity
   (GHz)     Reading          [dB/m]     [dB]    [dB]    [dB]     [dB]    Reading    (dBuV/m)     (dB)    (dBuV/m)     Margin    (Degs)    (cm)
             (dBuV)                                                      (dBuV/m)                                       (dB)
  * 1.019     46.1     PK2    24.4      -40.2    1.7     1.6       -      33.6           -          -        74         -40.4    343       367        H
  * 1.019    33.15     MAv1   24.4      -40.2    1.7     1.6       -      20.65         54       -33.35       -           -      343       367        H
    2.5      53.97     PK2    28.7      -43.3    2.7     2.6      .3      44.97          -          -        74        -29.03     0        118        H
    2.5      51.14     MAv1   28.7      -43.3    2.7     2.6      .3      42.14         54       -11.86       -           -       0        118        H
   1.857     76.53     PK2    27.4      -42.4    2.3     2.2      .5      66.53          -          -        74         -7.47    357       358        V
   1.859     47.36     MAv1   27.5      -42.4    2.3     2.2      .4      37.36         54       -16.64       -           -      357       358        V
    2.5      50.22     PK2    28.7      -43.3    2.7     2.6      .3      41.22          -          -        74        -32.78    28        277        V
    2.5      46.23     MAv1   28.7      -43.3    2.7     2.6      .3      37.23         54       -16.77       -           -      28        277        V
   6.415     40.57     PK2    34.7      -39.8    4.3     4.2      1.2     45.17          -          -        74        -28.83    29        301        V
   6.416     29.25     MAv1   34.7      -39.8    4.3     4.2      1.2     33.85         54       -20.15       -           -      29        301        V
    *5       47.94     PK2    33.3      -41.1    3.8     3.7      .2      47.84          -          -        74        -26.16    359       105        V
    *5       42.51     MAv1   33.3      -41.1    3.8     3.7      .2      42.41         54       -11.59       -           -      359       105        V

* - indicates frequency in CFR47 Pt 15 / IC RSS-Restricted Band
PK2 - KDB558074 Method: Maximum Peak
MAv1 - KDB558074 Option 1 Maximum RMS Average

                                                                High Channel – Data




                                                       Page 18 of 23
Honeywell International                                                                  Document #: 800-23065, Revision A
2 Corporate Center Dr., Melville, NY 11747                                                              TEL: (516) 577-2000
        This report shall not be reproduced except in full, without the written approval of Honeywell International


Report #: 50346-M2                                                                                Date: 2018-07-09
FCC ID: CFS8DLWFZW                                                                             IC ID: 573F-WFZW

Simultaneous Transmission

Configuration (Worse-case):


Wi-Fi – Antenna 2, 802.11b Mode, High Channel
Z-Wave – High Channel




                                                  30-1000MHz – Plot


Note: No additional emissions generated by simultaneous transmission




                                                       Page 19 of 23
Honeywell International                                                                  Document #: 800-23065, Revision A
2 Corporate Center Dr., Melville, NY 11747                                                              TEL: (516) 577-2000
        This report shall not be reproduced except in full, without the written approval of Honeywell International


Report #: 50346-M2                                                                                Date: 2018-07-09
FCC ID: CFS8DLWFZW                                                                             IC ID: 573F-WFZW




                                                     1-18GHz – Plot


Note: No additional emissions generated by simultaneous transmission




                                                       Page 20 of 23
Honeywell International                                                                  Document #: 800-23065, Revision A
2 Corporate Center Dr., Melville, NY 11747                                                              TEL: (516) 577-2000
        This report shall not be reproduced except in full, without the written approval of Honeywell International


Report #: 50346-M2                                                                                 Date: 2018-07-09
FCC ID: CFS8DLWFZW                                                                              IC ID: 573F-WFZW


Conducted Emissions (Mains)
Test Description
The EUT is placed on a non-conducting table 40 cm from the vertical ground plane and 80 cm above the horizontal
ground plane. The EUT is configured in accordance with ANSI C63.10 / C63.4.

The receiver is set to a resolution bandwidth of 9 kHz. Peak detection is used unless otherwise noted as quasi-peak
or average.

Line conducted data is recorder for both NEUTRAL and HOT lines.

Test Criteria

                           Reference                              Limit (dBuV)
                                                  Frequency Range (MHz) Quasi-Peak            Average
                   CFR 47 Subpart C, 15.207              0.15-0.5           66 to 56          56 to 46
                         RSS-GEN
                   CFR 47 Subpart B, 15.107                 0.5-5                   56           46
                          ICES-003                                                  60           50
                                                             5-30

Test Information

                                                     Temperature        Humidity     Pressure
          Tester    Test Location         Date                                                    Results (P/F)
                                                        (ºC)             (%RH)        (mbar)
           MA           RF Lab        06/27/2018        20.7              54.3         1005              P

Equipment List

 Instrument Type        ID #        Serial #         Manufacturer              Model            Cal Date      Cal Due
                                                                                                                Date
     Spectrum          11556     MY49430802             Keysight          N9030A (PXA)        12/19/2017     12/19/2018
     Analyzer
       LISN            11527       241259              Com-Power             LIN-120A         01/10/2018     01/10/2019
   Measurement         11543      Version 9.5             UL                 UL EMC              N/A            N/A
     Software
     RF Cable            -             -               Pasternack              CDE#1             N/A            N/A
   Environmental       11533        A078144        Extech Instruments          SD700          08/21/2017     08/21/2020
       Meter




                                                       Page 21 of 23
Honeywell International                                                                  Document #: 800-23065, Revision A
2 Corporate Center Dr., Melville, NY 11747                                                              TEL: (516) 577-2000
        This report shall not be reproduced except in full, without the written approval of Honeywell International


Report #: 50346-M2                                                                                  Date: 2018-07-09
FCC ID: CFS8DLWFZW                                                                               IC ID: 573F-WFZW

Test Results (Worse-case)




Line: L1
 Frequency    Meter    Det    LISN1 L1 [dB]   CDE Cable     Corrected     FCC Part 15   Margin    FCC Part 15   Margin
   (MHz)     Reading                            [dB]         Reading         QP          (dB)        AV          (dB)
             (dBuV)                                        (dB(uVolts))
  .15426      42.41     Pk        10.6           -.1          52.91         65.77       -12.86      55.77        -2.86
  .43904      32.16     Pk         10             .1          42.26         57.08       -14.82      47.08        -4.82
  .49549      35.91     Pk         10              0          45.91         56.08       -10.17      46.08         -.17
   .4942      26.02     Av         10              0          36.02         56.1        -20.08      46.1        -10.08
   .7595      24.89     Pk        9.9              0          34.79          56         -21.21       46         -11.21
  1.22475     26.63     Pk        9.9              0          36.53          56         -19.47       46          -9.47
  9.99725     38.83     Pk         10             .2          49.03          60         -10.97       50           -.97

Line: Neutral
 Frequency    Meter    Det    LISN1 L2 [dB]   CDE Cable     Corrected     FCC Part 15   Margin    FCC Part 15   Margin
   (MHz)     Reading                            [dB]         Reading         QP          (dB)        AV          (dB)
             (dBuV)                                        (dB(uVolts))
  .15181      43.68     Pk        10.6             0          54.28         65.9        -11.62      55.9         -1.62
  .43712      32.39     Pk         10              0          42.39         57.12       -14.73      47.12        -4.73
  .49613      36.07     Pk         10              0          46.07         56.06        -9.99      46.06          .01
  .49773      24.3      Av         10              0           34.3         56.04       -21.74      46.04       -11.74
  1.37338     27.72     Pk        9.9              0          37.62          56         -18.38       46          -8.38
  1.74675     26.66     Pk        9.9              0          36.56          56         -19.44       46          -9.44
  9.99725     39.25     Pk         10             .2          49.45          60         -10.55       50           -.55

Pk - Peak detector
Av - Average detector




                                                       Page 22 of 23
Honeywell International                                                                  Document #: 800-23065, Revision A
2 Corporate Center Dr., Melville, NY 11747                                                              TEL: (516) 577-2000
        This report shall not be reproduced except in full, without the written approval of Honeywell International


Report #: 50346-M2                                                                                Date: 2018-07-09
FCC ID: CFS8DLWFZW                                                                             IC ID: 573F-WFZW

                                                   END OF REPORT




                                                       Page 23 of 23
Honeywell International                                                                  Document #: 800-23065, Revision A
2 Corporate Center Dr., Melville, NY 11747                                                              TEL: (516) 577-2000
        This report shall not be reproduced except in full, without the written approval of Honeywell International



Document Created: 2018-07-09 15:09:46
Document Modified: 2018-07-09 15:09:46

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC