                                                           RF Exposure Report

                       Report No.: SA171006C01

                             FCC ID: CFS8DLRCHS5200W

                       Test Model: RCHS5200W

                 Received Date: Oct. 06, 2017

                         Test Date: Oct. 20 ~ Nov. 02, 2017

                     Issued Date: Nov. 09, 2017


                         Applicant: Honeywell International Inc.

                          Address: 2 Corporate Center Drive Melville NY 11747 United States Of America


                        Issued By: Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch

                    Lab Address: No. 47-2, 14th Ling, Chia Pau Vil., Lin Kou Dist., New Taipei City, Taiwan,
                                 R.O.C.
                  Test Location: No. 19, Hwa Ya 2nd Rd., Wen Hwa Vil., Kwei Shan Dist., Taoyuan City
                                 33383, TAIWAN (R.O.C.)




This report is for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted
only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this
report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product
unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you
provided to us. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence, provided,
however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time
shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Unless specific
mention, the uncertainty of measurement has been explicitly taken into account to declare the compliance or non-compliance to the specification. The report
must not be used by the client to claim product certification, approval, or endorsement by TAF or any government agencies.




Report No.: SA171006C01                                              Page No. 1 / 6                                             Report Format Version: 6.1.1


                                                                   Table of Contents
Release Control Record .................................................................................................................................. 3
1         Certificate of Conformity...................................................................................................................... 4
2         RF Exposure .......................................................................................................................................... 5
    2.1      Limits for Maximum Permissible Exposure (MPE) .............................................................................. 5
    2.2      MPE Calculation Formula ................................................................................................................... 5
    2.3      Classification ....................................................................................................................................... 5
3         Calculation Result of Maximum Conducted Power........................................................................... 6




Report No.: SA171006C01                                              Page No. 2 / 6                                              Report Format Version: 6.1.1


                                          Release Control Record


Issue No.             Description                                         Date Issued
SA171006C01           Original release.                                   Nov. 09, 2017




Report No.: SA171006C01                      Page No. 3 / 6        Report Format Version: 6.1.1


1    Certificate of Conformity


            Product: Smart Home Security Base Station

              Brand: Honeywell

        Test Model: RCHS5200W

    Sample Status: Engineering sample

          Applicant: Honeywell International Inc.

          Test Date: Oct. 20 ~ Nov. 02, 2017

         Standards: FCC Part 2 (Section 2.1091)
                          KDB 447498 D03 (January 17, 2014)
                          IEEE C95.1



The above equipment has been tested by Bureau Veritas Consumer Products Services (H.K.) Ltd.,
Taoyuan Branch, and found compliance with the requirement of the above standards. The test record, data
evaluation & Equipment Under Test (EUT) configurations represented herein are true and accurate accounts
of the measurements of the sample’s EMC characteristics under the conditions specified in this report.




      Prepared by :                                              , Date:        Nov. 09, 2017
                             Pettie Chen / Senior Specialist




     Approved by :                                               , Date:        Nov. 09, 2017
                               Ken Liu / Senior Manager




Report No.: SA171006C01                         Page No. 4 / 6                       Report Format Version: 6.1.1


2     RF Exposure
2.1     Limits for Maximum Permissible Exposure (MPE)

    Frequency Range          Electric Field     Magnetic Field       Power Density         Average Time
         (MHz)              Strength (V/m)      Strength (A/m)         (mW/cm2)              (minutes)
                             Limits For General Population / Uncontrolled Exposure
       300-1500                   …                    …                  F/1500                  30
      1500-100,000                …                    …                   1.0                    30
F = Frequency in MHz


2.2     MPE Calculation Formula
Pd = (Pout*G) / (4*pi*r2)
where
Pd = power density in mW/cm2
Pout = output power to antenna in mW
G = gain of antenna in linear scale
Pi = 3.1416
R = distance between observation point and center of the radiator in cm


2.3     Classification
The antenna of this product, under normal use condition, is at least 20cm away from the body of the user. So,
this device is classified as Mobile Device.




Report No.: SA171006C01                        Page No. 5 / 6                        Report Format Version: 6.1.1


3     Calculation Result of Maximum Conducted Power
Frequency Band            Max Power         Antenna Gain            Distance   Power Density            Limit
    (MHz)                   (dBm)               (dBi)                 (cm)       (mW/cm2)             (mW/cm2)
WLAN
     2412-2462              19.64                2.1                  20           0.030                   1
     5180-5240              20.08                2.4                  20           0.035                   1
     5260-5320              20.34                2.4                  20           0.037                   1
     5500-5700              20.71                2.4                  20           0.041                   1
     5745-5825              20.46                2.4                  20           0.038                   1
BT LE
     2402-2480              3.53                 1.3                  20           0.001                   1
Wise Link
    904.5~926.1             19.99                1.7                  20           0.029                   1



                       Electric field Electric field            Max Power      Power Density           Limit
       Mode
                     (dBuV/m) @3m (dBuV/m) @0.2m                  (dBm)          (mW/cm2)            (mW/cm2)
      Z wave                92.3               115.82                -2.93        0.0001                0.601
902MHz= 92.3+20log(3/0.2) = 115.82dBuV/m

                                            Max. Power (dBm)                     Total Power          Power Limit
    Frequency Band
                                    WLAN                        BT LE              (dBm)                (dBm)
       2.4GHz                       19.64                        3.53               19.75                 30

CONCULSION:
The WLAN & Wise Link can transmit simultaneously, the formula of calculated the MPE is:
CPD1 / LPD1 + CPD2 / LPD2 + ……etc. < 1
CPD = Calculation power density
LPD = Limit of power density

WLAN + Wise Link = 0.041 + 0.029 = 0.07

* WLAN & BT cannot transmit simultaneously.
Therefore, the maximum calculation of this situation is 0.07, which is less than the “1” limit.