Users Manual - Shock

FCC ID: CFS8DL6SHK

Users Manual

Download: PDF
FCCID_3764550

SiXSHOCK
Wireless Shock/Door/Window Sensor
Installation Instructions

The SiXSHOCK is a 3-zone wireless
shock/door/window sensor is intended for use with
Honeywell controls that support SiX™ series
devices.
It provides
• Reed switch/magnet zone
• External wired contact zone
• Built-in shock sensor zone
Typical shock protection area:
10 - 12 sq. ft. / 5 - 6 foot radius (3.05m – 3.66m /
1.52m – 1.83m radius)
The coverage area can vary depending on the
mounting surface.

Open the SiXSHOCK
Firmly slide the top and bottom housings in
opposite directions and pull them apart to open the
device.




Installation Options
The SiXSHOCK can be mounted with several
options:
• Loop 1: Built-in shock sensor alarm status
• Loop 2: Normally closed, built in reed switch,
  used with the included magnet (1)
• Loop 3: Externally wired, closed-circuit contact
  loop connected to the Terminal Block
   NOTE:Wiring limit is 3ft.
Gap specifications:
a. Make gap is at least 0.8" (1)
b. Break gap is at least 0.95" (1)
    (reduced about 30% for steel)


Mounting
TheSiXSHOCKsensor MUST be mounted as
follows:
• On swinging doors: mount on upper corner,
  opposite hinge is ideal
• On sliding windows and doors: on the frame
  (on moving section when magnet is used)
Double sided tape and screws provided for
mounting.
Signal Strength Guide                                                  Icon           Description             Signal Strength
Signal strength: Range of 1-4 bars (green); should be                               Four Green Bars
minimum 1 green bar for the Zone being programmed.
Four red bars indicate poor signal strength; the device                             Three Green Bars
should be relocated.                                                                                               Good
                                                                                    Two Green Bars
See the Control’s instructions for bar indication signal
strength values.                                                                     One Green Bar

                                                                                     Four Red Bars          Relocate the device


Enroll and Set Up
For the Lyric™ Controller
NOTE: The SiXSHOCK can be enrolled and
programmed before or after installation.
1. Set the Lyric Controller in Programming Mode:
   Security > Tools > [installer code] > Program >
   (scroll down) > SiX Programming.
2. Pull the battery tab to activate the SiXSHOCK. (Use
   the magnet if the battery tab is removed.)
3. The LED flashes (up to about 20 seconds*) during
   enrollment.
   • All services (Reed and Terminal Block) are enrolled
      in sequential (or next available) zone numbers.
   • The device sends its unique MAC ID (Serial
      Number); the controller registers the device and
      displays the transmitter data on screen.
   *NOTE: Enrollment time varies depending on the signal
   strength between the device and the controller.
4. When done, the LED is ON for 3 seconds and the
   control beeps to confirm enrollment.
   NOTE: If the device is not successfully enrolled during the
   enrollment period, the LED turns off and the device powers
   down. Activate a tamper, wired service (loop) or the reed
   switch to restart the enrollment process.
5. For each zone being used, press Edit to program it.
   Reed Switch Zone: press the Edit button to assign
   the Zone Descriptors and set the Device Types. Verify
   the Service and Response Types and set other                      NOTE: Once enrolled in a system, the SiXSHOCK cannot
   options as desired. Press Save.                                   be used with another controller until it is removed from the
   Terminal Bock Zone: select to enable and press the                current controller. See the Controller’s instructions for
   Edit button to assign the Zone Descriptors and set the            details.
   Device Types. Verify the Service and Response
   Types and set other options as desired. Press Save.               Sensor Location Feature: To verify the location of each
                                                                     SiX device in an installation, enter programming mode and
                                                                     select a SiX device. The device LED lights. Select it again
                                                                     to turn the LED off or select the next device to locate.


                                                                 2


6. Select SAVE again to complete enrollment.                     For the Lyric™ Gateway
   NOTE: If steps 5 and 6 are not completed, the device
   will automatically be deleted from the system when            Enroll and program using AlarmNet 360™.
   exiting Programming mode.
After enrolling, verify adequate signal strength by              Using AlarmNet 360
conducting Go/No Go tests (see controller’s instructions)        When AlarmNet 360 is ready to enroll, remove the sensor
with the device in its intended mounting location. Adjust        battery tab or use the magnet if the tab is removed. After
the device location and orientation as necessary.                the device is enrolled, the Green LED is on for 3 seconds.

24-Hour Enrollment Deletion and Default
If the device is enrolled in a panel different than the
intended panel, and you are unable to delete it from
the unintended panel, reset the device to factory
default setting:
1. Open the cover and remove the battery.
2. Hold down the tamper switch while reinserting the
    battery.
3. Reattach the cover.
This procedure is available for 24 hours after
enrollment with a panel and the device remains
powered (battery installed).


LED Indications

                          LED                        Status
                            Rapid Flashes for
                          about 20 seconds, then     Power Up – Enrollment
                            ON for 3 seconds
                                                     Power Up – Device enrolled; Wall or Cover Tamper activated. To stop
                                Slow Flashes         flashes, clear the tamper condition by reconnecting to the mounting plate
                                                     and reattaching the cover. It also times out after 10 minutes.
                                     ON              Sensor LED toggles on and off when the sensor is selected. See Sensor
                       (while in Programming Mode)   Location Feature. (Not available with Lyric Gateway.)


Battery Replacement
• Push the bottom latch of the
  mounting bracket back to disengage
  it. Then slide the back housing up
  and out to remove it from the
  mounting bracket.
• Slide the front and back housings in
  opposite directions and pull the
  housings apart.
• Remove the battery, wait 10
  seconds, then insert a new battery.
  Recommended batteries:
   Duracell DL123A
   Honeywell 466
   Huiderui CR123A
   Panasonic CR123A
• Place the front and back housings
  together and slide them together.
 BATTERY CAUTION: Risk of fire, explosion
 and burns. Do not recharge, disassemble, heat
 above 212°F (100°C) or incinerate. Dispose of
 used batteries properly. Keep away from
 children.
 NOTE: Constant exposure to high or low
 temperature or high humidity may reduce
 battery life.
                                                                3


  Specifications:                                                                                               Approval Listings:
  Battery: 1 x 3V Lithium, Honeywell 466, Panasonic CR123A,                                                     FCC / IC
   Duracell DL123A or Huiderui CR123A                                                                           cETLus Listed
  Tamper: Cover and Wall                                                                                          Conforms to UL 634
  RF Frequency: 2.4GHz                                                                                            Certified to ULC/ORD-C634
                                                                                                                Other Standards:
  Operating Temperature: 32° – 122° F / 0° – 50° C
                                                                                                                RoHS
   (Agency Compliance 32° – 120° F / 0° – 49° C)
  Relative Humidity: 95% max. (Agency Compliance - 93% max.),                                                   Product must be tested at
   non-condensing                                                                                               least once each year
  Dimensions: 1” H x 3.13” L x 1.61” W / 25.5 mm H x 79.5 mm L x 41 mm W

FEDERAL COMMUNICATIONS COMMISSION & INDUSTRY CANADA STATEMENTS
The user shall not make any changes or modifications to the equipment unless authorized by the Installation Instructions or User's Manual.
Unauthorized changes or modifications could void the user's authority to operate the equipment.

CLASS B DIGITAL DEVICE STATEMENT
This equipment has been tested to FCC requirements and has been found acceptable for use. The FCC requires the following statement for your
information: This equipment generates and uses radio frequency energy and if not installed and used properly, that is, in strict accordance with the
manufacturer's instructions, may cause interference to radio and television reception. It has been type tested and found to comply with the limits for a
Class B computing device in accordance with the specifications in Part 15 of FCC Rules, which are designed to provide reasonable protection against
such interference in a residential installation. However, there is no guarantee that interference will not occur in a particular installation. If this equipment
does cause interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to
correct the interference by one or more of the following measures:
• If using an indoor antenna, have a quality outdoor antenna installed.
• Reorient the receiving antenna until interference is reduced or eliminated.
• Move the radio or television receiver away from the receiver/control.
• Move the antenna leads away from any wire runs to the receiver/control.
• Plug the receiver/control into a different outlet so that it and the radio or television receiver are on different branch circuits.
• Consult the dealer or an experienced radio/TV technician for help.

INDUSTRY CANADA CLASS B STATEMENT
This Class B digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada.

FCC / IC STATEMENT
This device complies with Part 15 of the FCC Rules, and Industry Canada’s license-exempt RSSs. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause
undesired operation.
Cet appareil est conforme à la partie 15 des règles de la FCC et exempt de licence RSS d’Industrie Canada. Son fonctionnement est soumis aux
conditions suivantes: (1) Cet appareil ne doit pas causer d’interférences nuisibles. (2) Cet appareil doit accepter toute interférence reçue y compris les
interférences causant une réception indésirable.

                                                            RF EXPOSURE
   Warning – The antenna(s) used for this device must be installed to provide a separation distance of at least 7.8 inches (20 cm)
   from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter except in accordance
   with FCC and ISED multi-transmitter product procedures.
                                                             Mise en Garde
   Exposition aux Fréquences Radio : La/les antenne(s) utilisée(s) pour cet émetteur doit/doivent être installée(s) à une distance de
   séparation d'au moins 20 cm (7,8 pouces) de toute personne et ne pas être située(s) ni fonctionner parallèlement à tout autre
   transmetteur ou antenne, excepté en conformité avec les procédures de produit multi transmetteur FCC et ISED.

                                                                 Support and Warranty
     REFER TO THE INSTALLATION INSTRUCTIONS FOR THE CONTROL WITH WHICH THIS DEVICE IS USED, FOR DETAILS
     REGARDING LIMITATIONS OF THE ENTIRE ALARM SYSTEM.
        For the latest documentation and online support information, please go to:
                            https://mywebtech.honeywell.com/
                            For the latest warranty information, please go to:
                            www.honeywell.com/security/hsc/resources/wa.
                      For patent information, see www.honeywell.com/patents                        MyWebTech              Warranty            Patents


 2017 Honeywell International Inc. Honeywell is a
registered trademark of Honeywell International Inc.
                                                               2 Corporate Center Drive, Suite 100
All other trademarks are the properties of their respective     P.O. Box 9040, Melville, NY 11747
owners. All rights reserved.
                                                                   www.honeywell.com/security
                                                                                                                          SiXSHOCK 800-23972 11/17 Rev A