SiXPanic EXHIBIT 7-2 Manual

FCC ID: CFS8DL6PNC

Users Manual

Download: PDF
FCCID_3852348

SiXPANIC
2-Button Wireless Panic Key
Installation Instructions
This bi-directional wireless panic key is intended                                 The device can be used with a belt clip, lanyard,
for use with Honeywell controls that support                                       or wristband.
SiX™ series devices.
                                                                                   [images of belt clip, wristband, necklace]
To activate, press and hold both buttons briefly
until the LED flashes. To clear the alarm at the                                    LED Indications
control, enter a user code. To clear memory of                                      Green flashing: lights when unit is transmitting
alarm, select Disarm and enter a user code.                                         Red Flashing: indicates low battery (lights
                                                                                                    during key press)

Enroll and Program the SiXPANIC
For the Lyric™ Controller
Follow instructions in the Controller’s programming guide.
1. Set the Lyric Controller in Programming Mode: Security >
   Tools > [installer code] > Program > (scroll down) > SiX
   Programming.
2. Press and hold both buttons briefly until the LED flashes to
   activate the enrollment process.
3. The LED flashes green during enrollment (up to about 20
   seconds).
   NOTE: Enrollment time varies depending on the signal
   strength between the device and the controller.
   • The device sends its unique MAC ID (Serial Number) and
      Services information to the controller.
   • The controller registers the device and displays the
      transmitter data on screen.
4. When done, the LED lights solid green for 3 seconds to
   confirm enrollment.
   If enrollment is not confirmed, press and hold both buttons
   briefly again to restart the enrollment process.
5. Press Edit to set the Alarm Report option on/off (if selected,
   button press sends a report to the central station). Press       IMPORTANT: Once enrolled in a system, the SiXPANIC cannot
   Save. Enter an appropriate Zone Descriptor. Press Save.          be used with another controller until it is removed from the
                                                                    current controller. When removed from a system, the key fob will
The device can also be manually enrolled. See the Controller’s      revert to factory default settings.
Programming Guide for details.                                      Sensor Location Feature: To verify the location of each SiX
                                                                    device in an installation, enter programming mode and select a
For the Lyric™ Gateway                                              SiX device. The device LED lights. Select it again to turn the LED
Enroll and program using AlarmNet 360™.
                                                                    off, or select the next device to locate.
For other Controls                                                  After Enrolling: Verify adequate signal strength by conducting
For other Controls that support SiX Series devices, see the         Go/No Go tests (see controller’s instructions) with the device in
controller’s instructions for enrollment details.                   its intended mounting location. Adjust the device location as
                                                                    necessary.

24-Hour Enrollment Deletion and Default
If the device is enrolled in a panel different than the intended
panel, and you are unable to delete it from the unintended panel,                  Press and hold the left button 15 seconds.
reset the device to factory default setting:
Press and hold the left button for 15 seconds.
The device self-deletes from the panel it was enrolled in.
This procedure is available for 24 hours after enrollment with a
panel and the device remains powered (battery installed).


Battery Replacement
When the battery is low, the LED flashes red during transmission.
To replace the battery:
1. Remove the screws from the back housing and use a
    screwdriver to gently separate the front and back housings.
2. Use a screwdriver to carefully remove the battery.
3. Wait 10 seconds or press a key fob button for 2 seconds to
    ensure full power discharge.
4. Insert a new 3V Coin Cell battery as shown. Recommended
    replacement battery:
    Recommended Batteries: 3V Coin Cell                                                              BATTERY CAUTION: Risk of fire, explosion and burns. Do not recharge,
    Honeywell BL3-0004 (CR2450); Duracell DL2450;                                                    disassemble, heat above 212 F (100 C) or incinerate. Dispose of used
    Panasonic CR2450; Energizer CR2450                                                               batteries properly. Keep away from children.
5. Replace the front housing and secure the housings with the                                        NOTE: Constant exposure to high or low temperature or high humidity
    cover screw.                                                                                     may reduce battery life.

  Specifications                                                                                                     Approval Listings:
  Battery: 1 x 3V Coin Cell, Honeywell BL3-0004 (CR2450); Duracell DL2450;                                           FCC / IC
            Panasonic CR2450; Energizer CR2450                                                                       cETLus Listed
  RF Frequency: 2.4GHz                                                                                                Conforms to UL 1023 & UL 985
  Operating Temperature: 0° to 50° C / 32° to 122° F                                                                  Certified to ULC ORD- C1023
    (Agency compliance 0° to 49° C / 32° to 120° F)                                                                    & ULC-S545
  Relative Humidity: 95% max. (Agency compliance – 93% max.),                                                        Other Standards:
    non-condensing                                                                                                   SIA CP-01; RoHS
  Dimensions: 0.5” H x 1.5” L x 1.5” W / 13 mm H x 38 mm L x 38 mm W
                                                                                                                     Product must be tested at least once each year.

      IMPORTANT! This wireless key is intended as a convenience to the user and should not be considered as a life safety device.

                                                       IMPORTANT SECURITY NOTICE
      Please inform the User about the security importance of their wireless key (key fob), and what to do if it is lost.
      Explain that the key fob is similar to their keys or access card. If lost or stolen, another person can compromise their security
      system. They should immediately notify the Dealer/Installer of a lost or stolen key fob. The Dealer/Installer will then remove the
      key fob programming from the security system.

      FEDERAL COMMUNICATIONS COMMISSION & INDUSTRY CANADA STATEMENTS
      The user shall not make any changes or modifications to the equipment unless authorized by the Installation Instructions or User's Manual. Unauthorized changes
      or modifications could void the user's authority to operate the equipment.

      FCC / IC STATEMENT
      This device complies with Part 15 of the FCC Rules, and Industry Canada’s license-exempt RSSs. Operation is subject to the following two conditions: (1) This
      device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation.
      Cet appareil est conforme à la partie 15 des règles de la FCC et exempt de licence RSS d’Industrie Canada. Son fonctionnement est soumis aux conditions
      suivantes: (1) Cet appareil ne doit pas causer d’interférences nuisibles. (2) Cet appareil doit accepter toute interférence reçue y compris les interférences causant
      une réception indésirable.
                                                                                        RF EXPOSURE
      Warning – The antenna(s) used for this device must not be co-located or operating in conjunction with any other antenna or transmitter except in accordance
      with FCC and ISED multi-transmitter product procedures.
                                                                                        Mise en Garde
      Exposition aux Fréquences Radio : La/les antenne(s) utilisée(s) pour cet émetteur ne pas être située(s) ni fonctionner parallèlement à tout autre transmetteur
      ou antenne, excepté en conformité avec les procédures de produit multi transmetteur FCC et ISED.



             REFER TO THE INSTALLATION INSTRUCTIONS FOR THE CONTROL WITH WHICH THIS DEVICE IS USED, FOR
             DETAILS REGARDING LIMITATIONS OF THE ENTIRE ALARM SYSTEM.

                                                                                  Support and Warranty
       For the latest documentation and online support information, please go to:
         https://mywebtech.honeywell.com/
       For the latest warranty information, please go to:
         www.honeywell.com/security/hsc/resources/wa.
       For patent information, see www.honeywell.com/patents                                                           MyWebTech         Warranty           Patents



 2018 Honeywell International Inc. Honeywell and is a registered trademark of Honeywell International Inc.
All other trademarks are the properties of their respective owners. All rights reserved.

    www.honeywell.com/security                                                     2 Corporate Center Drive, Suite 100                     DOC CODE 128B BAR CODE HERE
                                                                                    P.O. Box 9040, Melville, NY 11747
                                                                                                                                           SiXPANIC    800-24148 4/18 Rev A