User Manual_20190313_v1 - SiXOCC EXHIBIT 7-2 Install Guide

FCC ID: CFS8DL6OCC1

Users Manual

Download: PDF
FCCID_4206660

SiXOCC
Wireless Occupancy Sensor
INSTALLATION INSTRUCTIONS
 The Honeywell Home SiXOCC Occupancy Sensor is a wireless device used with controllers that support Honeywell Home’s SiX™ series
 devices.
 The SiXOCC combines security motion detection and automation in one unit. Using automation, or occupancy mode allows the device to
 signal the control to turn a light on or off and/or a thermostat to a pre-programmed temperature.
 NOTE: Lights controlled via Z-Wave devices have not been evaluated by ETL.

SECURITY SENSOR                                                      MOUNTING LOCATION
 The security sensor reacts to movement and tells the panel          • The optimal range is obtained at a mounting height of 7’ 6”
 to react based on the control’s programming.                          (2.3m).
 1. Typically, it’s programmed as an interior follower.              • Allow a clear line-of-sight to all areas to protect.
 2. LED walk test mode indication, one for the intrusion             • Do not directly face windows.
    detection and the other for the occupancy detection. (See
    testing for more information.)                                    • Avoid close-proximity to moving machinery, fluorescent lights, and
                                                                        heating/cooling sources.
 3. Up to 40 pounds’ pet immunity.
                                                                     For use in applications with pets up to 40 pounds (36 kilograms).
    If the system is Armed, the control goes into alarm.
                                                                     In Applications with Animals:
    If the system is disarmed it turns the light on (or adjusts
    the thermostat) based on the explanation below.                   • Mount with the center of the device at 7.5 feet (2.3m)
                                                                      • Mount where pet cannot come within 6 feet (1.8m) of the sensor
OCCUPANCY SENSOR                                                        by climbing on furniture, stairs, boxes or other objects.
 When the control is disarmed (deactivated), the occupancy           Test each installation to determine exact level of animal immunity;
 sensor switches to occupancy mode and reacts to the user’s          levels vary based on environmental differences and the amount of
 programming in the control. Logic is as follows:                    heat radiated by an animal.
 General Operation
 1. First detection activates turns on the lights and/or
    adjusts the temperature.
      Any small movement, such as the turning a page of a
      book or swiping a tablet will continue to keep the light on
      and temperature at the programmed levels.
 2. When it stops detecting movement for a pre-defined
    time-period defined by the user/ installer, it will turn off
    the light and increase or lower the temperature until
    movement is detected again.
 Daylight Savings
 Daylight Savings sensor detects the lighting level in the
 room.
 1. Turns on lights only if the daylight is below a certain
     level and tries to keep the same amount of light in the
     room.
 2.   Once the daylight has been evaluated, the SiXOCC
      decides when to turn on the light. Depending on the
      level the light turns on to 25%, 50%, 75%, and 100%.
      Example: If the natural room light level is at 100%, then
                  the light does not turn on; at 0% natural light,
                  the light turns on to 100%.
 3.   The level the light turns on can be set to a certain % (vs.
      slowly increasing the light level). For example, any
      natural light level decrease turns on the light to 100%.
 Programmable to turn the feature on (described above), or
 off (when it detects any movement).




                                                                      1


MOUNTING OPTIONS
After enrolling, verify adequate signal strength
by conducting Go/No Go tests (see the
controller’s instructions) with the device in its
intended mounting location. Adjust the device
location and orientation as necessary.
The SIXOCC can be mounted on the wall or in
corners:
• [A] = Wall mounting holes.
• [B] = Corner mounting holes.
• The rear tamper plate MUST be mounted
   to a stud, solid wood, or with a robust wall
   anchor.




ENROLL THE SIXOCC
   NOTE: Once enrolled in a system, the sensor cannot be             4. Enrollment is confirmed when the LED is ON for 3 seconds.
         used with another controller until it is removed               NOTE: If the sensor is not successfully enrolled during
         from the current controller. See the Controller’s                    the enrollment period, the LED turns off and the
         instructions for details.                                            device enters a sleep mode. Activate a tamper or
Press down on the top latch and separate the front and back                   remove and reinsert the batteries to restart the
covers.                                                                       enrollment process.
1. Put the controller in Programming Mode and when prompted:            NOTE: Pet Immunity is selectable: Off or Up to
2. Remove the battery tab to activate and begin the enrollment                40 lbs (36 kg).
   process. Or, if powered, press the tamper.                        Sensor Location Feature: To verify the location of each SiX
3. The green LED beneath the batteries flashes (up to about 20       device in an installation, enter programming mode and select a
   seconds*) during enrollment. The device sends its unique          SiX device. The device LED lights. Select it again to turn the
   MAC ID (Serial Number) and Services information to the            LED off or select the next device to locate.
   controller.
   NOTE: Enrollment time varies depending on the signal
         strength between the device and the controller.




Signal Strength:
Range of 1-4 bars (green); should be                 Icon               Description                          Signal Strength
minimum 1 green bar for the Zone being
                                                                        Four Green Bars
programmed. Four red bars indicate poor
signal strength; the device should be
relocated. See the Controller’s instructions                            Three Green Bars
for bar indication signal strength values.                                                                         Good
                                                                        Two Green Bars

                                                                        One Green Bar

                                                                        Four Red Bars                       Relocate the device

                                                                 2


24-HOUR ENROLLMENT DELETION AND DEFAULT
If the device is enrolled in a panel different than the intended panel, and you are unable to delete it from the unintended panel, reset
default the device to factory default setting:
1. Open the cover and remove the batteries.
2. Insert the batteries while holding the tamper switch down for 10 seconds.
This procedure is available for 24 hours after enrollment with a panel and the device remains powered (batteries installed).

WALK TEST THE SIXOCC                                                      To restart a 10-minute Test period, activate the Test mode with
                                                                          the controller (see the Controller’s instructions), or use the
After power up and enrollment, the sensor automatically enters            flashlight feature (see the following section).
Walk Test mode.
                                                                          NOTE: the system must be disarmed to enter Test Mode.
Walk through the detection area and observe the LED.
                                                                          When in walk test the LED shows red for intrusion and
After 10 minutes, the sensor automatically exits Test mode,               green for occupancy.
disables the LED and enters normal operation mode.




FLASHLIGHT FEATURE
The flashlight feature is only available for the first 24 hours after the first power up, or
until the system is first armed. This feature is no longer available after the first
system arming.
Each time the flashlight features is used, and the system is disarmed, the walk test
timer restarts for 10 minutes.
When in walk test the LED shows red for intrusion and green for occupancy.
1. Use a flashlight with a bright light beam, and stand within 4ft (1.2 m) of the
   sensor.
2. Swing the light beam past the sensor Lens 3-5 times, holding the beam on the
   window for 0.5 second each pass.
NOTE: The flashlight feature only imitates or restarts the Test Mode and does not change
      any other sensor settings.




                                                                      3


DETECTION PATTERNS




BATTERY REPLACEMENT
• Press the latch at the top of the device and slide the front       • Place the front and back covers together and slide the front
  cover down to remove it.                                             cover upward as shown.
• Remove the batteries and wait 10 seconds, then insert the
                                                                     NOTE: Constant exposure to high or low temperature or
  new batteries. Recommended batteries: Panasonic
  CR123A, Honeywell 466, Huiderui CR123A, Duracell                         high humidity may reduce battery life.
  DL123A                                                             BATTERY CAUTION!
                                                                     Risk of fire, explosion and burns. Do not recharge, disassemble,
                                                                     heat above 212°F or incinerate. Dispose of used batteries
                                                                     properly. Keep away from children.




                                                                 4


 LED INDICATORS
                                                                        TIME
                                         PATTERN                                             OCCASION
                                                                        DURATION

FRONT RED LED (INTRUSION)
 Warm Up                                 Steady Blink (1s/1s)           6-45 seconds         Power On
                                         ON when zone
                                                                        Time of              When the user selects the zone in
 Sensor Location Feature                 selected; OFF when
                                                                        selection            question in controller programming
                                         not selected
 Enter/Exit walk test mode               Quick Flash                    2 seconds            Enter or Exit Walk Test mode
                                         Slow then long                 Flash if the
 Trouble                                                                                     Self-Test Error
                                         blinks                         error exists
 Movement Detected with no
                                                                                             Movement detected in walk test
 Pet Immunity / Panel                    Slow Blink                     3 seconds
                                                                                             mode
 programmable
 Movement Detected with
                                                                                             Movement detected in walk test
 Pet Immunity / Panel                    3s ON                          3 seconds
                                                                                             mode
 programmable
FRONT GREEN LED (OCCUPANCY)
                                                                                             Normal operation when no activity
 Off                                     N/A                            N/A
                                                                                             detected
                                                                                             Movement detected in walk test
 Occupant Detection                      3s Slow Blink                  3 seconds
                                                                                             mode
REAR GREEN LED
                                                                                             Powered on, seeking enrollment to
 Not enrolled in a network               Fast Blink                     0-60 seconds
                                                                                             the controller
                                                                                             Process is complete and
 Enrollment Confirmation                 3s ON                          3 seconds
                                                                                             enrollment confirmed
 Enrolled and programmed
                                         3 seconds ON                   3 seconds            Upon power up
 into the controller’s network
 Delete                                  Fast Blink                     2 seconds            During deletion from the panel
                                                                                             Tamper triggered, while the tamper
 Tamper (already enrolled)               Short Flash every 3s           10 minutes
                                                                                             is faulted


 SPECIFICATIONS
   Batteries .......................................................... Two 3-volt lithium; Duracell DL123A, Panasonic CR123A, or HUIDERUI CR123A.,
                                                                   Honeywell 466
   Full Range ....................................................... Security: 30ft x 42ft (9m x 12.8m) / Occupancy: 23ft x 32ft (7m x 9.8m)
   Angle of Detection ........................................... 90 Degrees
   Default Sensitivity Setting................................ Lowest Sensitivity, Pet Immunity Enabled
   Wall Mounting Height ...................................... 7’ – 9’ (2.1 m – 2.7 m); Optimal 7’6” (2.3 m).
   RF Frequency.................................................. 2.4 GHz
   Tamper ............................................................ Cover
   Dimensions ..................................................... 4.5 in. (11.4 cm) diameter, 2.5” (6.3 cm) deep
   Relative Humidity ............................................ 95% (Agency Compliance – 93%), Non-condensing
   Operating Temperature ................................... 32° – 122°F / 0° – 50°C
   Weight ............................................................. 4.34 oz. (123.04g)


 REFER TO THE INSTALLATION INSTRUCTIONS FOR THE CONTROL WITH WHICH THIS DEVICE IS USED, FOR DETAILS
 REGARDING LIMITATIONS OF THE ENTIRE ALARM SYSTEM.

RF EXPOSURE
Warning – The antenna(s) used for this device must be installed to provide a separation distance of at least 7.8 inches (20 cm) from all persons and
must not be co-located or operating in conjunction with any other antenna or transmitter except in accordance with FCC and ISED multi-transmitter
product procedures.
Mise en Garde
Exposition aux Fréquences Radio: La/les antenne(s) utilisée(s) pour cet émetteur doit/doivent être installée(s) à une distance de séparation d'au
moins 20 cm (7,8 pouces) de toute personne et ne pas être située(s) ni fonctionner parallèlement à tout autre transmetteur ou antenne, excepté en
conformité avec les procédures de produit multi transmetteur FCC et ISED.


                                                                                        5


 FEDERAL COMMUNICATIONS COMMISSION (FCC) & INDUSTRY CANADA (IC) STATEMENTS
 The user shall not make any changes or modifications to the equipment unless authorized by the Installation Instructions or User's Manual.
 Unauthorized changes or modifications could void the user's authority to operate the equipment.
 CLASS B DIGITAL DEVICE STATEMENT
 This equipment has been tested to FCC requirements and has been found acceptable for use. The FCC requires the following statement for
 your information:
 This equipment generates and uses radio frequency energy and if not installed and used properly, that is, in strict accordance with the
 manufacturer's instructions, may cause interference to radio and television reception. It has been type tested and found to comply with the limits
 for a Class B computing device in accordance with the specifications in Part 15 of FCC Rules, which are designed to provide reasonable
 protection against such interference in a residential installation. However, there is no guarantee that interference will not occur in a particular
 installation. If this equipment does cause interference to radio or television reception, which can be determined by turning the equipment off and
 on, the user is encouraged to try to correct the interference by one or more of the following measures:
 • If using an indoor antenna, replace it with a quality outdoor antenna.
 • Reorient the receiving antenna until interference is reduced or eliminated.
 • Move the radio or television receiver away from the receiver/control.
 • Move the antenna leads away from any wire runs to the receiver/control.
 • Plug the receiver/control into a different outlet so that it and the radio or television receiver are on different branch circuits.
 • Consult the dealer or an experienced radio/TV technician for help.
 INDUSTRY CANADA CLASS B STATEMENT
 This Class B digital apparatus complies with Canadian ICES-003.
 Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada.
 FCC / IC STATEMENT
 This device complies with Part 15 of the FCC Rules, and Industry Canada’s license-exempt RSSs. Operation is subject to the following two
 conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including
 interference that may cause undesired operation.
 Cet appareil est conforme à la partie 15 des règles de la FCC et exempt de licence RSS d’Industrie Canada. Son fonctionnement est soumis
 aux conditions suivantes: (1) Cet appareil ne doit pas causer d’interférences nuisibles. (2) Cet appareil doit accepter toute interférence reçue y
 compris les interférences causant une réception indésirable.

Responsible Party / Issuer of Supplier’s Declaration of Conformity: Ademco Inc., a subsidiary of Resideo Technologies, Inc., 2 Corporate Center
Drive., Melville, NY 11747, Ph: 516-577-2000

APPROVAL LISTINGS / APPROBATIONS HOMOLOGATIONS                                                         OTHER STANDARDS
FCC / IC                                                                                               SIA-PIR-01
cETLus Listed                                                                                          RoHS
 Conforms to UL 639
 Certified to ULC-S306-03


                SUPPORT, WARRANTY, & PATENT INFORMATION
For online support information, please go to:
https://mywebtech.honeywellhome.com/

For the latest warranty information, go to:
https://www.security.honeywellhome.com/hsc/resources/wa/index.html
                                                                                                     MyWebTech                  Warranty                Patents
For patent information, see https://www.resideo.com/patent




                                                       2 Corporate Center Drive, Suite 100
                                                        P.O. Box 9040, Melville, NY 11747
                                                         2018 Resideo Technologies, Inc.
                                                                www.resideo.com



                                                                  The Honeywell Home Trademark is used under license from Honeywell International Inc.
Ê800-23973cŠ                                                      All other trademarks are the properties of their respective owners. All rights reserved.

800-23973 2/18 Rev A



Document Created: 2019-01-03 10:03:18
Document Modified: 2019-01-03 10:03:18

© 2025 FCC.report
This site is not affiliated with or endorsed by the FCC