User Manual_20180228_v1 - SiXCO EXHIBIT 9-1 Install Guide

FCC ID: CFS8DL6CO

Users Manual

Download: PDF
FCCID_3768996

SiXCO Carbon Monoxide (CO) Detector / Monoxyde de carbone (CO)
Quick Installation Guide                                                                             Guide d'installation rapide
This device is intended for use with Honeywell controls that support SiX series devices              This device is intended for use with Honeywell controls that support SiX series devices
including the SiXCO. Check the control for compatibility with this device. This device               including the SiXCO. Check the control for compatibility with this device. This device
occupies one control panel zone.                                                                     occupies one control panel zone.
See Honeywell Installation Guide (P/N 800-23974–                                                                                  Voir les instructions d'installation complètes (800-23974 -
https://mywebtech.honeywell.com/) and the Limitations of                                                                          https://mywebtech.honeywell.com/) et les limites de cet
Carbon Monoxide Alarm Systems Insert (P/N 800-15144                                                                               insert de système d'alarme au monoxyde de carbone (800-
12/15) and Limitation of Carbon Monoxide Detectors (P/N                                                                           15144FC 12/15)
K14670V1 4/08 Rev. A).
                                                                                                                                  CARACTÉRISTIQUES
FEATURES                                                                                                                          Signalement de la fin de vie du détecteur de CO (détecteur
•   10-year life Carbon Monoxide (CO) sensor                                                                                         devant être remplacé)
•   CO Detector End-of-Life reporting (detector needs replacing)                                                                  • 10-year life Carbon Monoxide (CO) sensor
•   CO Maintenance Reporting                                                                                                      • CO Maintenance Reporting
•   Low Battery Detection                                                                                                         • Détection de pile faible
•   One Go / All Go: all CO detectors in the system programmed                                                                    • Une seule fois pour tout : Tous les détecteurs de fumée du
    as one-go-all-go will sound on alarm.                                                                                            système programmés comme « Une seule fois pour tout »
                                                                                                                                     retentiront.


POWER UP                                                                                                                          POWER UP
•    Remove battery pull tab. Be sure batteries are seated                                                                        •   Remove battery pull tabs. Be sure batteries are seated
     properly to avoid a low battery condition after 15 seconds.                                                                      properly to avoid a low battery condition after 15 seconds.
•    Upon power up, Green LED Blinks every 2 secs / Sounder is                                                                    •   Upon power up, Green LED Blinks every 2 secs / Sounder is
     Silent.                                                                                                                          Silent.




ENROLLMENT                                                                                                                                                      ENRÔLEMENT
IMPORTANT NOTES:                                                                                                                                                IMPORTANT NOTES:
• The Carbon Monoxide (CO) has a                                                                                                                                • The Carbon Monoxide (CO) has a
  unique MAC ID number (serial                                                                                                                                    unique MAC ID number (serial
  number) and is used for                                                                                                                                         number) and is used for
  enrollment.                                                                                                                                                     enrollment.
• Once enrolled, the device cannot                                                                                                                              • Once enrolled, the device cannot
  be used with another system                                                                                                                                     be used with another system until
  until it is removed from the                                                                                                                                    it is removed from the current
  current controller. See the 24-                                                                                                                                 controller. See the 24-hour
  hour Enrollment Deletion section                                                                                                                                Enrollment Deletion section below
  below or the controller’s                                                                                                                                       or the controller’s instructions.
  instructions.
                                                                                                                                                                Enroll the Device Services (CO)
Enroll the Device Services (CO)
                                                                                                                                                                1. Remove the detector from the
1. Remove the detector from the                                                                                                                                    base plate (tamper switch must
   base plate (tamper switch must                                                                                                                                  be faulted when enrolling).
   be faulted when enrolling).
                                                                                                                                                                2. Put the control panel in Zone
2. Put the control panel in Zone                                                                                                                                   Programming mode.
   Programming mode.
                                                                                                                                                                   For Lyric Controller: Security >
    For Lyric Controller: Security >                                                                                                                               installer code > Program >
    installer code > Program >                                                                                                                                     (scroll down) > SiX
    (scroll down) > SiX                                                                                                                                            Programming
    Programming
3. Pull the battery tab to activate                                                                                                                             3. Pull the battery tab to activate
   enrollment process (be sure                                                                                                                                     enrollment process (be sure
   batteries are seated properly to                                                                                                                                batteries are seated properly to
   avoid a false low battery                                                                                                                                       avoid a false low battery
   condition). If the battery tab has                                                                                                                              condition). If the battery tab has
   already been removed and the                                                                                                                                    already been removed and the
   unit is powered up, press the                                                                                                                                   unit is powered up, press Test
   Test switch for less than 3                                                                                                                                     switch for less than 3 seconds to
   seconds to activate the                                                                                                                                         activate the enrollment process.
   enrollment process.
4. The device attempts enrollment (green LED flashes about 8 seconds). If successful, the            4. The device attempts enrollment (green LED flashes about 8 seconds). If successful, the
   green LED lights steady for 3 seconds and the detector chirps indicating a successful                green LED lights steady for 3 seconds and the detector chirps indicating a successful
   enrollment.                                                                                          enrollment.
    If the LED does not light steady, enrollment failed. Retry by pressing Test switch for less        If the LED does not light steady, enrollment failed. Retry by pressing Test switch for less
    than 3 seconds.Supervision: Detector supervision is factory set for 1 minute and is not            than 3 seconds.Supervision: Detector supervision is factory set for 1 minute and is not
    programmable.                                                                                      programmable.
5. To assign zone descriptors for each of the zones and/or change device type or zone                5. To assign zone descriptors for each of the zones and/or change device type or zone
   response type, select the zone then select Edit and make the desired changes. Press                  response type, select the zone then select Edit and make the desired changes. Press
   Save when done.                                                                                      Save when done.



24-Hour Enrollment Deletion                                                                          24-Hour Enrollment Deletion
Use this procedure within 24 hours of initial enrollment to delete this device from the              Use this procedure within 24 hours of initial enrollment to delete this device from the
controller. This allows reenrollment in a specific controller in case enrollment in that             controller. This allows reenrollment in a specific controller in case enrollment in that
controller failed (i.e., the device inadvertently enrolled in a different controller). This resets   controller failed (i.e., the device inadvertently enrolled in a different controller). This resets
the device to factory default settings and removes the communication link data in the                the device to factory default settings and removes the communication link data in the
controller in which it is enrolled, allowing the device to be reenrolled in the desired              controller in which it is enrolled, allowing the device to be reenrolled in the desired
controller.                                                                                          controller.

NOTE: Pressing and holding the test button (while powering the detector) will arm the                NOTE: Pressing and holding test button (while powering the detector) will arm the
      detector to perform a reset to factory defaults.                                                     detector to perform a reset to factory defaults.


TO SILENCE THE DETECTOR                                                                              POUR FAIRE TAIRE LE DÉTECTEUR
Press the test switch. The detector sounds again after 5 minutes if the alarm condition              Appuyez sur le bouton de test. Le détecteur sonne de nouveau après 5 minutes si la
continues.                                                                                           condition d'alarme est toujours présente.
NOTE: The detector can only be silenced once per event.                                              NOTE: The detector can only be silenced once per event.


MOUNTING                                   CEILING / PLAFOND                                           WALL / MUR                                            MONTAGE
If the device is not in its final mounting                                                                                                                   Si l’appareil n’est pas dans son
location when enrolled, conduct Go/No                                                                                                                        emplacement de montage final lorsqu’il
Go tests (see controller’s instructions)                                                                                                                     est enrôlé, effectuez des tests Tout ou
to verify adequate signal strength.                                                                                                                          rien (voir les instructions du panneau de
Adjust the device location and                                                                                                                               commande) pour vérifier que la
orientation as necessary.                                                                                                                                    puissance dusignal est adéquate. Au
                                                                                                                                                             besoin, modifiez l'emplacement ou
                                                                                                                                                             l'orientation du dispositif.




FUNCTIONAL TEST                                                                                                                                                      REPLACE BATTERIES /
Product must be                                                                                                                                                    REMPLACEMENT DES PILES
tested at least once
each year
TEST FONCTIONNEL
Le fonctionnement du
produit doit être vérifié
au moins une fois par
année




PERIODIC CLEANING                                                                                                                                            NETTOYAGE PÉRIODIQUE
NOTE                                                                                                                                                         NOTE :
Notify the proper                                                                                                                                            Avisez les personnes compétentes
authorities that the                                                                                                                                         qu'un détecteur de CO est hors service
CO detector is                                                                                                                                               pour cause d'entretien et que, par
undergoing                                                                                                                                                   conséquent, le système sera
maintenance and the                                                                                                                                          temporairement hors service.
system will
temporarily be out of
service.


LED Indication & Sounder during Test and Trouble /
Confirmation par DEL et sonore durant le test et la maintenance
                                                                                                       SPECIFICATIONS / SPÉCIFICATIONS:
                                                                                                       Battery / Pile:
                                        Status LED (Top) / Estado
MODE/ MODO                                                          Sounder / Sonador                  2 x 3V, CR123A Lithium; Panasonic CR123A or DURACELL DL123, DL123A
                                        del LED
                                        Blink Red once every sec /                                     Sensitivity / Sensibilité :
                                                                     Temp-4                            Meets UL2034/UL2075 CO sensitivity requirements
CO Test 1ab / Test CO                   Clignotement rouge une fois
                                                                     Tempo. -4
                                        par seconde                                                    Audible Signal: 85dBA / Signal audible: 85 dBA
RealTest™ Functional CO Test      1ab
                                                                                                       Dimensions: Thick 1.65 in (4.19 cm); Diameter 5.30in (13.462cm)
                                        Blink Green once a sec /
– Waiting for gas entry / Test                                              Silent /
                                        clignotement en vert par                                       Weight: 7.7 oz; 218.3 g / Poids : 7,7 oz; 218.3 g
fonctionnel de CO RealTest™ 2ab                                             Silencieux
                                        seconde
– En attente d'une entrée de gaz                                                                       Tamper / Interrupteurs antisabotage: Wall Tamper/Wall Tamper

RealTest™ Functional CO Test -                                                                         Operating Temperature / Température de fonctionnement : 32°– 122° F / (0°– 50° C)
Successful gas entry /                  Blink Red every 10 secs /                                      Storage Temperature / Plage de température de stockage : 14-158°F
                                                                            Temp-4
Test fonctionnel de CO                  clignotement en rouge à                                                                                                     (-10°-70°C)
                                                                            Tempo. -4
RealTest™ 2ab – Entrée de gaz           toutes les 10 secs
effectuée avec succès                                                                                  Relative Humidity / Humidité de fonctionnement :
                                                                                                        20-95% RH (Agency Compliance – 93% max.), non-condensing
                                                                            Chirp every 45 seconds
                                        Blink Amber once every                                         NOTE: Batteries available at your local retailer or distribution center.
                                                                            after
                                        45 sec /
Low Battery / Pile faible                                                   7 days / Émet des          NOTE : Batteries disponibles chez votre revendeur ou votre centre de distribution
                                        Clignotement ambre à toutes
                                                                            épiements toutes les             local.
                                        les 45 secs
                                                                            45 secs après 7 jours
                                        Double Blink Amber every 5                                     Caution!
CO Trouble/                                                                 Silent /
                                        secs / Clignotement ambre à                                    The batteries used in this device may present a fire or chemical burn hazard if mistreated.
Défectuosité du dét. de CO                                                  Silencieux                 Do not recharge, disassemble, heat above 212°F (100°C) or dispose of in fire. Use two
                                        toutes les 3 secs
CO End of Life2- First 29 days /        Double Blink Amber every 3                                     Panasonic CR123A or DURACELL DL123, DL 123A Lithium batteries. Use of other batteries
                                                                            Silent /                   may present a risk of fire or explosion. Keep used batteries away from children. Dispose of
Fin de vie du dét. de CO4-              secs / Clignotement ambre à
                                                                            Silencieux                 used batteries properly.
Premier 29 jours                        toutes les 3 secs
                                                                                                       Remove old batteries. Wait 10 seconds and then replace with two new batteries. To avoid a
CO End of Life2- After 30 days /        Double Blink Amber every 3          Chirp every 45 secs/
                                                                                                       low battery indication when installing new batteries, both batteries must be installed within
Fin de vie du dét. de CO4- après        secs / Clignotement ambre à         Émet des épiements         15 seconds of installing the first one. Any low battery condition that may have occurred
30 jours                                toutes les 3 secs                   toutes les 45 secs         should clear when the back plate is installed.
 1a Test activated by pressing and releasing the test switch; Detector is functioning
                                                                                                       Mise en garde!
     properly (within proper sensitivity). See Functional Test section for Functional Test
                                                                                                       Les piles utilisées dans ce dispositif peuvent présenter des risques d'incendie ou de brûlure
     activation and procedure. / Test activé par le bouton de test; Le détecteur                       chimique si elles sont mal traitées. Ne rechargez pas, ne désassemblez pas, ne faites pas
     fonctionne adéquatement (avec la sensibilité appropriée).                                         chauffer et ne jetez pas au feu les piles à plus de 100 °C (212 °F). Utilisez des dos piles au
 1b If Test mode is activated and the LED and Sounder do not function, check for                       lithium Panasonic CR123A ou DURACELL DL123, DL 123A. L'utilisation d'autres types de
     maintenance or trouble conditions. / Si le mode de test est activé et que la DEL et               piles peut présenter des risques de feu ou d'explosion. Gardez les vieilles piles hors de la
     l'avertisseur sonore ne fonctionnement pas, vérifiez s'il y a des conditions de                   portée des enfants. Débarrassez-vous des batteries utilisées de façon appropriée.
     maintenance ou de défectuosité.
                                                                                                       Retirez les vieilles piles. Attendez 10 secondes et remplacer-les par dos nouvelles piles.
 2   Starts chirping after 30 days, continues until the batteries are replaced or die / Le
                                                                                                       Pour éviter une indication de piles faibles lorsque vous installez de nouvelles piles, les dos
     détecteur commence à émettre des pépiements 30 jours après sur une base
                                                                                                       (2) piles doivent être installées en deçà de 15 secondes après l'installation de la première.
     continue jusqu'à ce que la pile soit remplacée ou morte.                                          Toute condition de pilles faibles qui aurait pu se produire devrait être rétablie une fois la
NOTE: For programming, see the Controller’s instructions.                                              plaque arrière installée.
NOTE: Pour la programmation des alarmes de fumée ou de CO et Tamper, consultez les
       instructions du contrôleur.                                                                     REFER TO THE INSTALLATION INSTRUCTIONS FOR THE CONTROL WITH WHICH THIS
                                                                                                       DEVICE IS USED, FOR DETAILS REGARDING LIMITATIONS OF THE ENTIRE ALARM SYSTEM.
Approval Listings / Approbations Homologations:
FCC/IC                                                                                                 POUR LES LIMITES DU SYSTÈME D’ALARME AU COMPLET, REPORTEZ-VOUS AU
Listed to UL 2075, and CSA 6.19 MAR2001 (R2016) / Conforme aux normes UL 2075, ou                      GUIDE D’INSTALLATION DU PANNEAU DE COMMANDE.
CSA 6.19 MAR2001 (R2016).
Other Standards / Autres normes: RoHS
                                                                                                       Support / Pour de l’assistance en ligne, visitez : https://mywebtech.honeywell.com/
 FEDERAL COMMUNICATIONS COMMISSION & INDUSTRY CANADA STATEMENTS
                                                                                                       U.S. warranty / U.S. garantie: www.honeywell.com/security/hsc/resources/wa
 The user shall not make any changes or modifications to the equipment unless authorized by the
                                                                                                       For patent info, see: / Pour des informations sur les brevets, voir :
 Installation Instructions or User's Manual. Unauthorized changes or modifications could void the
 user's authority to operate the equipment.                                                            www.honeywell.com/patents
 FCC / IC STATEMENT This device complies with Part 15 of the FCC Rules, and Industry Canada’s
 license-exempt RSSs. Operation is subject to the following two conditions: (1) This device may not
 cause harmful interference, and (2) This device must accept any interference received, including
 interference that may cause undesired operation.
 Cet appareil est conforme à la partie 15 des règles de la FCC et exempt de licence RSS d’Industrie
 Canada. Son fonctionnement est soumis aux conditions suivantes: (1) Cet appareil ne doit pas                       MyWebTech                   Warranty / Garantie                  Patents / brevets
 causer d’interférences nuisibles. (2) Cet appareil doit accepter toute interférence reçue y compris
 les interférences causant une réception indésirable.
Agile Reference #800-23974 1/18 Rev A

                                                                                                                                         2018 Honeywell International Inc. Honeywell and is a registered
I56-0620-000                                                                                                                            trademark of Honeywell International Inc.
                                                                                                                                        All other trademarks are the properties of their respective owners. All
                                                                                                                                        rights reserved.