User Manual_20180410_v1 - SiXC2W EXHIBIT 7-1 Install Guide

FCC ID: CFS8DL6C2W

Users Manual

Download: PDF
FCCID_3822314

SiXC2W Convert to Wireless / Convert to Wireless
Quick Installation Guide                                                                    Guide d'installation rapide
The Honeywell SiXC2W is an eight zone hardwire to wireless converter used with              The Honeywell SiXC2W is an eight zone hardwire to wireless converter used with
controllers that support Honeywell’s SiX™ series devices. It is useful in retrofit 12-      controllers that support Honeywell’s SiX™ series devices. It is useful in retrofit 12-volt
volt security system applications where existing contact wiring was used. It uses           security system applications where existing contact wiring was used. It uses those
those existing wired contacts and converts them to wireless.                                existing wired contacts and converts them to wireless

FEATURES                                                                                    CARACTÉRISTIQUES
 •     Provides 12-volts for devices such as motion detectors, glass breaks, etc.               •     Provides 12-volts for devices such as motion detectors, glass breaks, etc.
       NOTE: Only two devices may be powered using the auxiliary output on the                        NOTE: Only two devices may be powered using the auxiliary output on the SiXC2W.
               SiXC2W.                                                                          •     Provides 24-hour battery backup. (4-hour if external devices are connected). NOTE:
 •     Provides 24-hour battery backup (4-hour if external devices are connected).                    It immediately sends a power loss signal to the controller in the event the power is
       NOTE: It immediately sends a power loss signal to the controller in the event                  lost.
       the power is lost.                                                                       •     When no battery is connected, low battery      message will send to control panel.
 •     When no battery is connected, low battery message will send to control                         When battery is connected, and if battery voltage drops below 3.6VDC, a low battery
       panel.                                                                                         message sends to the control panel.
       When battery is connected, and if battery voltage drops below 3.6VDC, a low
                                                                                                      When only the battery is connected, and if the battery voltage 3.4 V, system will shut
       battery message sends to the control panel.
                                                                                                      down.
       When only the battery is connected, and if the battery voltage 3.4 V, system             •     Support one button calibration
       will shut down.                                                                          •     Automatic zone configuration
 •     Support one button calibration                                                           •     Easy setup in three steps
 •     Automatic zone configuration                                                             •     Cover tamper protection
 •     Easy setup in three steps
 •     Cover tamper protection
                                                                                                    IMPORTANT!
                                                                                                    Not to be used for fire, heat, or carbon monoxide detectors.
     IMPORTANT!
     Not to be used for fire, heat, or carbon monoxide detectors.


CALIBRATING                                                                                                                           CALIBRATING
The calibration process enables the SiXC2W to learn                                                                                   The calibration process enables the SiXC2W to learn
what zones are to be active and what value EOL resistors                                                                              what zones are to be active and what value EOL
are used.                                                                                                                             resistors are used.

     IMPORTANT!                                                                                                                        IMPORTANT!
     Unused zones that are open ARE NOT                                                                                                Unused zones that are open ARE NOT
     recognized and reported.                                                                                                          recognized and reported
                                                                                                                                       1.   Ensure all zones are connected and not faulted.
1.   Ensure all zones are connected and not faulted.                                                                                   2.   On the SiXC2W, press and release the top middle
2.   On the SiXC2W, press and release the top middle                                                                                        button.
     button.                                                                                                                           3.   Indicator LED #2 will flash Red for 1/2 second;
3.   Indicator LED #2 will flash Red for 1/2 second; then                                                                                   then LED #3 turns steady Green.
     LED #3 turns steady Green.                                                                                                        4.   Calibration is in process
4.   Calibration is in process                                                                                                         5.   DONE. The SiXC2W is calibrated and ready to
5.   DONE. The SiXC2W is calibrated and ready to enroll                                                                                     enroll in the control panel.
     in the control panel.                                                                                                            NOTES:
NOTES:                                                                                                                                 • If the SiXC2W loses both AC and battery backup
 • If the SiXC2W loses both AC and battery backup                                                                                        power, the zone calibration data is retained.
   power, the zone calibration data is retained.                                                                                       • If there is an existing resistor, it MUST have a value
 • If there is an existing resistor, it MUST have a value                                                                                between 1K and 10K.The unit comes with eight (8)
   between 1K and 10K.The unit comes with eight (8)                                                                                      2.2K resistors for zones that don’t have one.
   2.2K resistors for zones that don’t have one.

     IMPORTANT!                                                                                                                        IMPORTANT!
     Once the SiXC2W is calibrate, any change in                                                                                       Once the SiXC2W is calibrate, any change in the
     the zone resistance the module must be                                                                                            zone resistance the module must be
     re-calibrated.                                                                                                                    re-calibrated.


ENROLLING / ENROLLING
Lyric Control                                                                                        Lyric Control
Lyric Controller Enrollment Process, See Controller’s installation instructions for its              Lyric Controller Enrollment Process, See Controller’s installation instructions for it’s
proper programming process.                                                                          proper programming process.
For Lyric Gateway                                                                                    For Lyric Gateway
Use AlarmNet 360™ to enroll and program this sensor.                                                 Use AlarmNet 360™ to enroll and program this sensor.
For Other Controls                                                                                   For Other Controls
For other controls that support SiX series devices, see the controller’s installation app for        For other controls that support SiX series devices, see the controller’s installation app for
details                                                                                              details
NOTE: Once enrolled in a system, the SiXC2W cannot be used with another controller NOTE: Once enrolled in a system, the SiXC2W cannot be used with another controller
      until it is removed from the current controller. See the Controller’s instructions until it is removed from the current controller. See the Controller’s instructions
      for details.                                                                       for details.


MOUNTING / MONTAGE                                                                                               Signal strength:
                                                                                                                  • Rang of 1-4 bars (green), should be a minimum 1 green bar for
                                                                                                                    the zone being programmed.
                                                                                                                  • Four Red Bards indicate poor signal strength; the device should
                                                                                                                    be relocated.
                                                                                                                  • See the controller’s instruction for bar indication signal
                                                                                                                    strength values.
                                                                                                                      Icon      Description                   Signal Strength
                                                                                                                                4 Green Bars

                                                                                                                                3 Green Bars
                                                                                                                                                              Good
                                                                                                                                2 Green Bars

                                                                                                                                1 Green Bar

                                                                                                                                4 Red Bars                    Relocate




TAMPER/LOW BATTERY REPORTING                                                                           TAMPER/LOW BATTERY REPORTING
The SiXC2W reports this condition to the control. If a low battery or tamper condition The SiXC2W reports this condition to the control. If a low battery or tamper condition
exists all zones used on the module shows a trouble on the control.                    exists all zones used on the module shows a trouble on the control.


    IMPORTANT:                                                                                           IMPORTANT:
    The first battery test occurs 1 hour after power up. To quickly verify a good                        The first battery test occurs 1 hour after power up. To quickly verify a good
    backup battery, unplug and then plug back in the power supply; the system                            backup battery, unplug and then plug back in the power supply; the system will
    will perform a battery test within 1 minute.                                                         perform a battery test within 1 minute.


LED INDICATIONS                                                                                          BATTERY REMOVAL AND INSTALLATION
LED # / LED #               Functions / Functions
1 (Green / Green)           Blinks once upon RF signal transmission (HW zone
                            trigger/tamper and/or a fault message), slow blink for a cover
                            tamper, quick blinks for enrollment or deletion / Blinks once
                            upon RF signal transmission (HW zone trigger/tamper and/or a
                            fault message), slow blink for a cover tamper, quick blinks for
                            enrollment or deletion
2 (Red / Red)               Blinks 1s / 1s off when module needs calibrating / Blinks 1s /
                            1s off when module needs calibrating
3 (Green / Green)           Steady on when the module has been calibrated. / Steady on
                            when the module has been calibrated.
4 (Green and Red /          Green: 5VDC Power from the plug-in transformer is present
Green and Red)              Red (blinking 1sec on / 1 sec off): Running on battery, DC
                            power not present. / Green: 5VDC Power from the plug-in
                            transformer is present Red (blinking 1sec on / 1 sec off):
                            Running on battery, DC power not present.
Approval Listings / Approbations Homologations:
FCC / IC - ETL Listed to UL268 & 521
cETL Listed to ULC S530 & S531
Other Standards / Autres normes: RoHS                                                                     Caution: The batteries used in this device may present a fire or chemical burn
 FEDERAL COMMUNICATIONS COMMISSION & INDUSTRY CANADA                                                      hazard if mistreated. Do not recharge, disassemble, heat above 212°F
 STATEMENTS                                                                                               (100°C) or dispose of in fire. Use Panasonic CR123A or DURACELL DL123,
 The user shall not make any changes or modifications to the equipment unless                             DL 123A Lithium batteries. Use of other batteries may present a risk of fire or
 authorized by the Installation Instructions or User's Manual. Unauthorized changes                       explosion. Keep used batteries away from children. Dispose of used batteries
 or modifications could void the user's authority to operate the equipment.                               properly.
                                                                                                          Remove old batteries. Wait 10 seconds and then replace with four new
 FCC / IC STATEMENT This device complies with Part 15 of the FCC Rules, and
                                                                                                          batteries. To avoid a low battery indication when installing new batteries, both
 Industry Canada’s license-exempt RSSs. Operation is subject to the following two
                                                                                                          batteries must be installed within 15 seconds of installing the first one. Any
 conditions: (1) This device may not cause harmful interference, and (2) This device
                                                                                                          low battery condition that may have occurred should clear when the back
 must accept any interference received, including interference that may cause
                                                                                                          plate is installed.
 undesired operation.
                                                                                                          Mise en garde : Les piles utilisées dans ce dispositif peuvent présenter des
 Cet appareil est conforme à la partie 15 des règles de la FCC et exempt de licence                       risques d'incendie ou de brûlure chimique si elles sont mal traitées. Ne
 RSS d’Industrie Canada. Son fonctionnement est soumis aux conditions suivantes:                          rechargez pas, ne désassemblez pas, ne faites pas chauffer et ne jetez pas au
 (1) Cet appareil ne doit pas causer d’interférences nuisibles. (2) Cet appareil doit                     feu les piles à plus de 100 °C (212 °F). Utilisez des piles au lithium
 accepter toute interférence reçue y compris les interférences causant une                                Panasonic CR123A ou DURACELL DL123, DL 123A. L'utilisation d'autres
 réception indésirable.                                                                                   types de piles peut présenter des risques de feu ou d'explosion. Gardez les
                                                                                                          vieilles piles hors de la portée des enfants. Débarrassez-vous des batteries
SPECIFICATIONS / SPÉCIFICATIONS:
                                                                                                          utilisées de façon appropriée.
                                                                                                          Retirez les vieilles piles. Attendez 10 secondes et remplacer-les par quatre
 Voltage
 Transformer Part # ................................... 300-10259                                         nouvelles piles. Pour éviter une indication de piles faibles lorsque vous
 Input Voltage ............................................... 100 ~ 240VAC, 50 ~60 Hz                    installez de nouvelles piles, les dos (2) piles doivent être installées en deçà de
 Operating Voltage ..................................... 5VDC                                             15 secondes après l'installation de la première. Toute condition de pilles
 Maximum Transformer Distance ...... 9.8ft. (3m)                                                          faibles qui aurait pu se produire devrait être rétablie une fois la plaque arrière
 Voltage Output ........................................... 12VDC @ 100mA (Up to three sets of 20–24      installée.
                                                                 gauge wiring)                            REFER TO THE INSTALLATION INSTRUCTIONS FOR THE CONTROL WITH
 Battery/ Pile ................................................. P/N 300-10342                            WHICH THIS DEVICE IS USED, FOR DETAILS REGARDING LIMITATIONS OF
                                                                                                          THE ENTIRE ALARM SYSTEM.
 Environmental                                                                                            POUR LES LIMITES DU SYSTÈME D’ALARME AU COMPLET, REPORTEZ-
 Operating Temp ......................................... 14 F (-10C) to 140F (60C)                   VOUS AU GUIDE D’INSTALLATION DU PANNEAU DE COMMANDE
                                                          NOTE: Charging the lithium battery stops
                                                                 when temperature is below 32F          See Honeywell Installation Guide P/N           Voir les instructions d'installation
                                                                 (0C)                                   800-24139–                                     complètes 800-24139-
 Relative Humidity ...................................... 95%, Non-condensing / 95% max. sans            https://mywebtech.honeywell.com/.              https://mywebtech.honeywell.com/.
                                                          condensation
                                                                                                         Support / Pour de l’assistance en ligne, visitez :
 Physical                                                                                                https://mywebtech.honeywell.com/
 Dimensions .................................................. Length 7.0 in (178 mm) x                  U.S. warranty / U.S. garantie: www.honeywell.com/security/hsc/resources/wa
                                                                Width 4.5 in (114 mm) x                  For patent info, see: / Pour des informations sur les brevets, voir :
                                                                Depth 1.5 in (38mm)                      www.honeywell.com/patents
 Mounting Hardware ................................. Double stick tape and screws
 Zone Resistance......................................... 1K to 10K Ohm EOL Resistors
 Zone Wiring .................................................. 1,000ft (Each Zone)
 Radio Frequency
 Transmission Range ................................ 300ft (91.5m)                                                 MyWebTech                 Warranty / Garantie                 Patents / brevets



                                                                                                                                       2018 Honeywell International Inc. Honeywell and is a registered
                                                                                                                                      trademark of Honeywell International Inc.
                                                                                                                                      All other trademarks are the properties of their respective owners. All
                                                                                                                                      rights reserved.



Document Created: 2018-03-20 10:26:07
Document Modified: 2018-03-20 10:26:07

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC