Test Report

FCC ID: CFS8DL5800PIR-OD2

Test Report

Download: PDF
FCCID_4310355

                                     849 NW STATE ROAD 45
                                     NEWBERRY, FL 32669 USA
                                     PH: 888.472.2424 OR
                                     352.472.5500
                                     EMAIL: INFO@TIMCOENGR.COM
                                     HTTP://WWW.TIMCOENGR.COM




   FCC PART 15.231(a) & RSS-210 (i9) ANNEX 1
     MOMENTARILY OPERATED TRANSMITTER
                      COMBO TEST REPORT
            Applicant                    ADEMCO INC.
                               2 CORPORATE CENTER DRIVE
              Address                SUITE 1009040
                                   MELVILLE NY 11747
Product Model Number                     5800PIR-OD2
  Product Description          Outdoor PIR Motion Detector
                FCC ID               CFS8DL5800PIR-OD2
                      IC               573F-5800PIR-OD2
Date Sample Received                      4/12/2019
         Date Tested                      4/12/2019
            Tested By                     Tim Royer
        Approved By                      Franklin Rose

            Report           Version         Description      Issue Date
           Number            Number
       857UT19TestReport      Rev1           Initial Issue    04/12/2019
                              Rev1         Revised Radiated   05/22/2019
                                              Emissions



 THE ATTACHED REPORT SHALL NOT BE REPRODUCED EXCEPT IN FULL
  WITHOUT THE WRITTEN APPROVAL OF TIMCO ENGINEERING, INC.


                                             TABLE OF CONTENTS

GENERAL REMARKS .................................................................................................. 3

GENERAL INFORMATION ............................................................................................... 4

TEST RESULTS SUMMARY ............................................................................................. 5

TEST SETUP ................................................................................................................ 5

RADIATED SPURIOUS EMISSIONS ................................................................................. 6

RADIATED SPURIOUS EMISSIONS ................................................................................. 7

  Test Data: Emissions from 9 KHz to the 10th harmonic of the Fundamental ....................... 9

OCCUPIED BANDWIDTHF ............................................................................................ 10

  Test Data: Occupied Bandwidth Measurement Table .................................................... 10

  Test Data: 20 dB Occupied Bandwidth Plot................................................................. 11

  Test Data: 99% Occupied Bandwidth Plot .................................................................. 12

TEST EQUIPMENT LIST ............................................................................................... 13

State of the measurement Uncertainty.......................................................................... 14




Applicant:        ADEMCO INC.
FCC ID:           CFS8DL5800PIR-OD2
IC:               573F-5800PIR-OD2
Report:           857UT19TestReport_Rev2                                                               Page 2 of 14


GENERAL REMARKS

The attached report shall not be reproduced except in full without the written
permission of Timco Engineering Inc.


Summary

The device under test does:
      Fulfill the general approval requirements as identified in this test report and
      was selected by the customer.
      Not fulfill the general approval requirements as identified in this test report

Attestations

This equipment has been tested in accordance with the standards identified in this
test report. To the best of my knowledge and belief, these tests were performed using
the measurement procedures described in this report.

All instrumentation and accessories used to test products for compliance to the
indicated standards are calibrated regularly in accordance with ISO 17025
requirements.

I attest that the necessary measurements were made at:

Timco Engineering Inc.
849 NW State Road 45
Newberry, FL 32669



Tested by:
 Name and Title: Tim Royer, Project Manager/Testing Engineer


Date: 4/18/2019




Reviewed and approved by:
Name and Title: Franklin Rose, Project Manager/EMC Specialist

Date: 4/19/2019




Applicant:   ADEMCO INC.
FCC ID:      CFS8DL5800PIR-OD2
IC:          573F-5800PIR-OD2
Report:      857UT19TestReport_Rev2                                       Page 3 of 14


GENERAL INFORMATION

             EUT Description     Outdoor PIR Motion Detector
                      FCC ID     CFS8DL5800PIR-OD2
               Model Number      5800PIR-OD2
              IC Certification   573F-5800PIR-OD2
     Operating Frequency         344.94 MHz
             Test Frequencies    344.94 MHz
                                    110–120Vac/50– 60Hz
        EUT Power Source            DC Power 12V
                                    Battery Operated Exclusively
                                    Prototype
                   Test Item        Pre-Production
                                    Production
                                    Fixed
        Type of Equipment           Mobile
                                    Portable
                                 Temperature: 24-26ºC
              Test Conditions    Relative humidity: 50-65%
                                 Barometric Pressure: 1024mb
                                 Timco Engineering Inc. located at 849 NW State Road 45
                 Test Facility   Newberry, FL 32669 USA. Designation #: US1070, ISED 2056-
                                 A
   Modification to the EUT       NONE
                                 For radiated emissions testing a continuously transmitting
                                 modulated carrier was used, for verification of duty cycle and
                Test Exercise
                                 compliance with periodic operation a normally operating
                                 transmitter was used
    Regulatory Standards         FCC CFR Title 47 Part 15C
                                 ANSI C63.10: 2013
 Measurement Standards           FCC CFR Title 47 Part 15.31, 15.33, 15.35
                                 RSS-GEN (i4)




Applicant:      ADEMCO INC.
FCC ID:         CFS8DL5800PIR-OD2
IC:             573F-5800PIR-OD2
Report:         857UT19TestReport_Rev2                                           Page 4 of 14


TEST RESULTS SUMMARY

                                             IC RSS §       RESULTS
   Requirement          FCC Rules Part No.
                                                          Pass/Fail/NA

                           15.231(b)         210 A1.1.2
Spurious Emissions
                           15.209(a)          GEN 8.9        Pass
  and Harmonics
                          15.205(a)(b)        GEN 8.10


      Occupied              15.231(c)        210 A1.1.3
                                                             Pass
     Bandwidth              15.215(c)         GEN 6.6



TEST SETUP

Supporting Peripheral
                                                 N/A
    Equipment




Applicant:   ADEMCO INC.
FCC ID:      CFS8DL5800PIR-OD2
IC:          573F-5800PIR-OD2
Report:      857UT19TestReport_Rev2                        Page 5 of 14


RADIATED SPURIOUS EMISSIONS

FCC Rules Part No.:           15.231(b), 15.209 (a), 15.205(a) (b)

IC RSS:                       210 § A1.1 Table A, RSS-Gen § 8.9, & 8.10

Requirements:

                 Fundamental and Harmonics not in Restricted Bands
         Fundamental     Field Strength of   Field Strength of Harmonics and
          Frequency        Fundamental              Spurious Emissions
            (MHz)            (dBµV/m)                (dBµV/m @ 3m)
        40.66 to 40.70         67.04                      47.04
          70 to 130            61.94                      41.94
          130 to 174      61.94 to 71.48              41.94 to 51.48
          174 to 260           71.48                      51.48
          260 to 470      71.48 to 81.94              51.48 to 61.94
        470 and above      81.94(12500)                   61.94

                                   Restricted Band Emissions
             Frequency (MHz)                               Limits
               9 – 490 kHz                   2400/F (kHz) μV/m @ 300 meters
             490 – 1705 kHz                  24000/F (kHz) μV/m @ 30 meters
             1705 – 30 MHz                 29.54 dBµV/m measured @ 30 meters
                 30 – 88                    40.0 dBµV/m measured @ 3 meters
                88 – 216                    43.5 dBµV/m measured @ 3 meters
               216 – 960                    46.0 dBµV/m measured @ 3 meters
               Above 960                    54.0 dBµV/m measured @ 3 meters

No fundamental frequency is allowed in the restricted bands.

No harmonic or spurious emissions may exceed the level of the fundamental carrier
frequency.




Applicant:      ADEMCO INC.
FCC ID:         CFS8DL5800PIR-OD2
IC:             573F-5800PIR-OD2
Report:         857UT19TestReport_Rev2                                    Page 6 of 14


RADIATED SPURIOUS EMISSIONS

Fundamental Emission Limit Formula:

   1) For the band 130-174 MHz, uV/m at 3 meters = 56.81818(F)-6136.3636;

   2) For the band 260-470 MHz, uV/m at 3 meters = 41.6667(F)-7083.3333.

       Where F is the fundamental emission frequency in MHz

Example Calculation of limit @ 433.92 MHz:

41.6667 (433.9)-7083.3333 = 10,995.85 uV/m

20log (10,995.85) = 80.82 dBuV/m

Harmonics and Spurious Emissions Limit:

   1) 20 dBc for all emissions outside of restricted bands

   2) General limits of 15.209(a) & RSS-Gen for emissions inside restricted bands


3 Meter Field Strength Limit for this EUT:

             Fund Freq       Fund Limit       Harm & Spur       Restricted
               (MHz)         (dBuV/m)          (dBuV/m)           Bands
              344.94           77.25             57.25        Limit of 15.209




Applicant:   ADEMCO INC.
FCC ID:      CFS8DL5800PIR-OD2
IC:          573F-5800PIR-OD2
Report:      857UT19TestReport_Rev2                                    Page 7 of 14


RADIATED SPURIOUS EMISSIONS

Test Method:          ANSI C63.10 § 6.3 – 6.6 Radiated Emissions Unlicensed Devices

The EUT was placed on a table with dimensions of 1m by 1.5m, 80 cm high below 1
GHz and 150 cm high above 1 GHz. The EUT was placed in the center of the table.
The table used for radiated measurements is capable of continuous rotation. The
spectrum was scanned from 9 KHz or the lowest frequency generated to the 10th
harmonic of the fundamental.

Peak readings were taken in three (3) orthogonal planes when necessary and the
highest readings were converted to average readings based on the duty cycle.

When an emission was found, the table was rotated to produce the maximum signal
strength. At this point, the antenna was raised and lowered from 1m to 4m. The
antenna was placed in both the horizontal and vertical planes.

Formula of Conversion Factors:

The field strength at 3m was established by adding the meter reading of the spectrum
analyzer to the antenna correction factor supplied by the antenna manufacturer plus
the coax loss. The antenna correction factors are stated in terms of dB/m. The gain of
the preselector was accounted for in the spectrum analyzer reading.

       Example:

        Freq.        Meter Reading         ACF      Cable Loss     Field Strength
        MHz              dBμV             dB/m         dB         dBμV/m @ 3 m
         33               20             +10.36       +1.2            = 31.56




Applicant:      ADEMCO INC.
FCC ID:         CFS8DL5800PIR-OD2
IC:             573F-5800PIR-OD2
Report:         857UT19TestReport_Rev2                                 Page 8 of 14


RADIATED SPURIOUS EMISSIONS


Test Data: Emissions from 9 KHz to the 10th harmonic of the Fundamental


  Tuned       Emission        Meter                                   Filter    Correction     Field
                                       Antenna     Coax     Duty
   Freq      Frequency       Reading                                Insertion     Factor     Strength   Margin   Limit
                                       Polarity   Loss Db   Cycle
   MHz           MHz          dBu V                                   Loss        dB/M       dBu V/M
  344.94        689.90        33.34       V        3.07     20.00      3.00        20.89       40.30    16.95    57.25
  344.94        689.90        26.61       H        3.07     20.00      3.00        20.89       33.57    23.68    57.25
  344.94        344.94        67.17       V        2.12     20.00      2.00        14.10       65.39    11.86    77.25
  344.94        344.94        60.48       H        2.12     20.00      2.00        14.10       58.70    18.55    77.25
  344.94       1034.80   *    32.86       V        3.75     20.00      4.00        27.24       47.85     6.15     54
  344.94       1034.80   *    34.17       H        3.75     20.00      4.00        27.24       49.16     4.84     54
  344.94       1379.80   *    19.07       H        4.31     20.00      4.00        29.23       36.61    17.39     54
  344.94       1379.80   *    33.32       V        4.31     20.00      4.00        29.23       50.86     3.14     54
  344.94       1724.70        18.24       V        4.81     20.00      5.00        29.42       37.47    19.78    57.25
  344.94       1724.70        17.07       H        4.81     20.00      5.00        29.42       36.30    20.95    57.25
  344.94       2069.60        28.83       H        5.27     20.00      5.00        31.51       50.61     6.64    57.25
  344.94       2069.60        23.90       V        5.27     20.00      5.00        31.51       45.68    11.57    57.25
  344.94       2414.60        20.29       V        5.62     20.00      6.00        32.11       44.02    13.23    57.25
  344.94       2414.60        13.95       H        5.62     20.00      6.00        32.11       37.68    19.57    57.25
  344.94       2759.50   *    14.54       H        6.10     20.00      6.00        32.45       39.09    14.91     54
  344.94       2759.50   *    14.60       V        6.10     20.00      6.00        32.45       39.15    14.85     54
  344.94       3104.50        14.54       V        6.44     20.00      6.00        33.40       40.38    16.87    57.25
  344.94       3104.50        14.64       H        6.44     20.00      6.00        33.40       40.48    16.77    57.25
  344.94       3449.40        16.63       H        6.84     20.00      7.00        32.93       43.40    13.85    57.25
  344.94       3449.40        19.21       V        6.84     20.00      7.00        32.93       45.98    11.27    57.25


                 * -Denotes restricted bands which must comply with limits 15.209

Note: Emissions that are 20 dB below the limit are not required to be reported.




Applicant:        ADEMCO INC.
FCC ID:           CFS8DL5800PIR-OD2
IC:               573F-5800PIR-OD2
Report:           857UT19TestReport_Rev2                                                          Page 9 of 14


OCCUPIED BANDWIDTH

FCC Rules Part No.:      15.231(C), & 15.215(c)

IC RSS:                  210 § A1.1.3, & GEN § 6.6

Requirements:
                   The bandwidth of the emission shall fall completely inside the
                   band of operation, and be no wider than .25% of the center
                   frequency for devices operating between 70 and 900 MHz.

                   For FCC compliance the Bandwidth is determined at the points 20
                   dB down from the modulated carrier.

                   For IC compliance the Bandwidth is determined as the 99% power
                   bandwidth.

Test Method:       ANSI C63.10 § 6.9.2 Occupied bandwidth Relative procedure
                   ANSI C63.10 § 6.9.3 Occupied bandwidth 99% Power


Test Data:         Occupied Bandwidth Measurement Table


                                                 Measured   Measured 99%
                 Tuned Frequency        Limit
                                                 20 dB BW       BW
                     (MHz)              (KHz)
                                                   (KHz)       (KHz)
                      344.94            862.35    26.41        111.09

                         Margin (KHz)             835.94       751.26



Results Meet Requirement




Applicant:   ADEMCO INC.
FCC ID:      CFS8DL5800PIR-OD2
IC:          573F-5800PIR-OD2
Report:      857UT19TestReport_Rev2                                        Page 10 of 14


OCCUPIED BANDWIDTH


Test Data:                 20 dB Occupied Bandwidth Plot

                                           20 dB BW =26.41kHz


                                                       * RBW   2 kHz     Delta 2 [T1 ]
                                                       * VBW   10 kHz                   0.57 dB
           Ref    0 dBm              Att   25 dB           SWT 125 ms          26.414493007 kHz

           0                                                             Marker 1 [T1 ]
                                                                                     -39.61 dBm
                                                                                                   *
                                                                               344.923685166 MHz    A
           -10

  1 RM *
  VIEW
           -20




           -30


                                                   1   2

           -40      D1 -40.29 dBm



           -50


                                                                                                   3DB
           -60                                                                                     AC




           -70




           -80




           -90



           -100

           Center   344.94 MHz             48.47836364 kHz/             Span    484.7836364 kHz




  Date: 19.APR.2019       14:35:16




Results Meet Requirements




Applicant:          ADEMCO INC.
FCC ID:             CFS8DL5800PIR-OD2
IC:                 573F-5800PIR-OD2
Report:             857UT19TestReport_Rev2                                                         Page 11 of 14


OCCUPIED BANDWIDTH


Test Data:                 99% Occupied Bandwidth Plot

                                           99% BW =111.09kHz


                                                      * RBW   2 kHz     Marker 1 [T1 ]
                                                      * VBW   10 kHz                -20.29 dBm
           Ref    0 dBm              Att   5 dB        SWT 125 ms             344.937669309 MHz

           0                                                            OBW111.096250000 kHz
                                                                        Temp 1 [T1 OBW]
                                                                                    -50.11 dBm     A
           -10
                                                                              344.885617220 MHz
  1 RM *                                                                Temp 2 [T1 OBW]
                                                  1
  VIEW
           -20                                                                      -49.76 dBm
                                                                              344.996713470 MHz


           -30




           -40


                                           T1                   T2
           -50


                                                                                                  3DB
           -60                                                                                    AC




           -70




           -80




           -90



           -100

           Center   344.94 MHz             48.47836364 kHz/            Span    484.7836364 kHz




  Date: 19.APR.2019       14:34:23




Results Meet Requirements




Applicant:          ADEMCO INC.
FCC ID:             CFS8DL5800PIR-OD2
IC:                 573F-5800PIR-OD2
Report:             857UT19TestReport_Rev2                                                        Page 12 of 14


TEST EQUIPMENT LIST

                                                  Serial     Cal/Char
   Device        Manufacturer       Model                                    Due Date
                                                 Number        Date
 Antenna:
  Biconical          Eaton          94455-1        1096      08/01/17        08/01/19
    1096
 Antenna:
Log-Periodic     Electro-Metrics    LPA-25         1122      07/26/17        07/26/19
    1122
 CHAMBER           Panashield         3M           N/A       12/31/17        12/31/19
 Antenna:
  Double-
   Ridged         ETS-Lindgren       3117        00041534    03/01/17        03/01/20
 Horn/ETS
   Horn 2
 Software:
    Field                                        Version
                     Timco            N/A                      N/A              N/A
  Strength                                       4.10.7.0
  Program
 Antenna:
                  ETS-Lindgren       6502        00062529    12/11/17        12/11/19
Active Loop
  EMI Test
Receiver R &        Rohde &
                                    ESU 40        100320     08/28/18        08/28/21
 S ESU 40           Schwarz
 Chamber
                                                KMKM-0244-
Coaxial Cable
                                   Chamber 3     01; KMKM-
- Chamber 3
                   Micro-Coax       cable set     0670-00;   08/09/16        08/09/19
  cable set
                                    (Primary)   KFKF-0198-
  (Primary)
                                                     01
 Bore-sight
  Antenna
                 Sunol Sciences      TLT2          N/A         N/A              N/A
 Positioning
   Tower




*EMI RECEIVER SOFTWARE VERSION

The receiver firmware used was version 4.43 Service Pack 3




Applicant:      ADEMCO INC.
FCC ID:         CFS8DL5800PIR-OD2
IC:             573F-5800PIR-OD2
Report:         857UT19TestReport_Rev2                                  Page 13 of 14


State of the measurement Uncertainty

The data and results referenced in this document are true and accurate. The measurement
uncertainty was calculated for all measurements listed in this test report according To CISPR
16–4 or ENTR 100-028 Specification for radio disturbance and immunity measuring apparatus
and methods – Part 4: “Uncertainty in EMC Measurements” and is documented in the Timco
Engineering, Inc. quality system according to DIN EN ISO/IEC 17025.              Furthermore,
component and process variability of devices similar to that tested may result in additional
deviation. The manufacturer has the sole responsibility of continued compliance of the device.
Hereafter the best measurement capability for Timco Engineering, Inc. is reported:

       Test Items                             Measurement       Notes
                                              Uncertainty
        RF Frequency Accuracy                 ± 49.5 Hz         (1)
        RF Conducted Power                    ±0.93dB           (1)
        Conducted spurious emission of        ±1.86dB
        transmitter valid up to 40GHz
        Occupied Bandwidth                     ±2.65%
        Radiated RF Power                      ±1.4dB
        Maximum frequency deviation:
          Within 300 Hz and 6kHz of audio
        freq.                                  ±1.88%
          Within 6kHz and 25kHz of audio
        Freq.                                  ±2.04%
        Adjacent channel power                 ±1.47dB          (1)
        Transient Frequency Response           ±1.88%
        Temperature                            ±1.0°C           (1)
        Humidity                               ±5.0%
This uncertainty represents an expanded uncertainty expressed   at approximately the 95%
confidence level using a coverage factor of k=1.96.




                                 END OF TEST REPORT




Applicant:    ADEMCO INC.
FCC ID:       CFS8DL5800PIR-OD2
IC:           573F-5800PIR-OD2
Report:       857UT19TestReport_Rev2                                        Page 14 of 14


ADEMCO INC.
FCC ID:  CFS8DL5800PIR-OD2
IC:      573F-5800PIR-OD2

TEST SET UP PHOTOS

Radiated Emissions Above 1 GHz


Radiated Emissions Below1 GHz


    Report Template Revision History

                                                                      Revision
    Document Name                   Description of Change                         Approved By
                                                                       Date
PT 15231a RSS210 Combo TX                Initial Issue                 160415       SS Sanders
            Rpt                Added Document History to Template      160920        G Greene

    \\timco-file\tesys2\TimcoOffice\Templates\TestReports\FCC\UnlicensedDevices\PT 15231a
    RSS210 Combo TX Rpt_160920.docx



Document Created: 2019-06-07 05:57:35
Document Modified: 2019-06-07 05:57:35

© 2025 FCC.report