RF Exposure Info Rev 2

FCC ID: CCKPC0209

RF Exposure Info

Download: PDF
FCCID_4360803

                                          MPE Evaluation


                                                 FCC

Maximum exposure limits from CFR 47, FCC Part 1.1310:

                      Table 1—Limits for Maximum Permissible Exposure (MPE)

Frequency range Electric field strength Magnetic field strength Power density Averaging time
      (MHz)              (V/m)                  (A/m)             (mW/cm2)       (minutes)
                      (A) Limits for Occupational/Controlled Exposure
0.3-3.0                              614                    1.63           *100             6
3.0-30                            1842/f                   4.89/f      *900/f  2            6
30-300                              61.4                   0.163             1.0            6
300-1,500                                                                 f/300             6
1,500-100,000                                                                  5            6
                 (B) Limits for General Population/Uncontrolled Exposure
0.3-1.34                             614                    1.63           *100            30
1.34-30                            824/f                   2.19/f      *180/f2             30
30-300                              27.5                   0.073             0.2           30
300-1,500                                                               f/1500             30
1,500-100,000                                                                1.0           30




                                               Page 1 of 2


                                          Table 2 – Power Density Calculations, FCC

                                                      Output
                                                      power +10%        Minimum
                          Antenna    Output           for               Seperation Power
            Frequency     Gain*      power            tolerance         Distance   Density     Limit

            MHz           dBi        mW               mW                cm           mW/cm^2   mW/cm^2
                  905.6          0            1.76              1.94           20.00   0.00039    0.604
                    915          0            1.37              1.51           20.00   0.00030    0.610
                  924.4          0            0.91              1.00           20.00   0.00020    0.616


Note: The user’s manual will stipulate that a 20cm distance from the user is to be maintained.

*Antenna gain was set to 0 because power is reported as EIRP and already has antenna gain taken into account

The power density is calculated as shown below:

       S = (P x G)/(4 x π x d^2) – used to calculate exposure at 20 cm

       d = √(S/(P x G) x 4 X π) – used to calculate minimum distance to meet limits

S= power density
P = transmitter conducted power (in mW)
G = antenna numeric gain
D = distance to radiation center (20 cm)




                                                        Page 2 of 2



Document Created: 2019-07-10 11:34:35
Document Modified: 2019-07-10 11:34:35

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC