1115 WIRELESS TEMPERATURE




                                                 Y
SENSOR AND FLOOD DETECTOR
Installation Guide




                                                R
                                        1
                                             PROGRAM THE PANEL
                                               The 1115 Wireless Temperature Sensor and Flood Detector can
                                               be programmed with up to four zones. When programming
                                               the 1115 in the panel, refer to the panel programming guide as
                                        needed.




                                               A
                                        Note: When a wireless receiver is installed, powered down and
                                        powered up, the panel is reset, or programming is complete, the
                                        supervision time is reset. If the receiver has been powered down for
                                        more than one hour, the 1115 may take up to an additional hour to
        Figure 1: 1115 Wireless         send a supervision message unless tripped, tampered, or powered
       Temperature Sensor and           up. This operation extends battery life. A missing message may
           Flood Detector               display on the keypad until the supervision message is sent.




                                             IN
                                            1. In ZONE INFORMATION, enter the ZONE number and press
                                                CMD.
         DESCRIPTION                            Note: Zones must be entered sequentially. For example, if you
                                                begin by programming zone 80, you would need to program
     The 1115 Wireless Temperature              zone 81 as the next contact.
     Sensor and Flood Detector is           2. Enter the ZONE NAME and press CMD.
   designed to be used in a variety
    of applications. The 1115 has an        3. Select SV (Supervisory) as the Zone Type and press CMD.
   internal temperature sensor that
                                            4. At the NEXT ZONE prompt, select NO. If you see the
   can be set to detect cold, hot, or
      warm temperature ranges.                  WIRELESS ZONE prompt, select YES.
                                        M
     When combined with the                 5. Enter the eight-digit SERIAL NUMBER and press CMD.
    remote T280R temperature                6. Enter the CONTACT number being used.
    probe, the 1115 can be set to
   monitor refrigerated or freezing
                                                Note: Contacts can be entered in any order. Refer to Table 1
            temperatures.                       to select the correct contact.
   The 1115 can also be paired with         7. Enter the SUPRVSN TIME and press CMD.
   the remote 470PB water sensor            8. At the NEXT ZONE prompt, select YES and continue to
  and used in situations where flood
                                                program up to three more zones.
          LI


        detection is necessary.
  Depending on a customer’s needs,
   the 1115 can be programmed with




                                        2
    up to four zones and serve as a
  temperature sensor, flood detector,
                or both.                        INSTALL THE BATTERIES
                                                  After the transmitter has been programmed into the panel,
                                                  install the batteries. Use only 3.0V lithium batteries, DMP
                                                  Model CR123A, or the equivalent battery from a local retail
         E




         Compatibility                  outlet. Keep in mind, when setting up a wireless system, program
     All DMP 1100 Series Wireless
        Receivers and burglary
                                        zones and connect the receiver before installing batteries in the
     panels. See the last page for      transmitters.
         compatibility details.             1. Remove the cover by pushing the button on the end of the
                                               cover and gently pulling upwards.
R




                                            2. Observing polarity, place the battery in the holder and press
                                               into place.
     What is Included?
  ƒƒ One 1115 PCB mounted in a
     two‑part housing
  ƒƒ One 3V lithium CR123A battery
  ƒƒ One 2M EOL resistor
P




  ƒƒ Mounting screws
                                                                                  LT-1547 © 2016 Digital Monitoring Products, Inc.
                                                                                                                            16462


3
                                                                                                      Tamper
        SELECT A LOCATION                                                                                              Survey




                                                       Y
                                                                                                      Switch
                                                                                                                       LED
        The 1115 provides a survey capability to allow one person
        to confirm communication with the wireless receiver or
        panel while the cover is removed. This allows you to easily
determine the best location for the 1115. Be sure to choose a location
                                                                                              T   C   F
on a flat wall or single-gang box away from large metal objects.




                                                      R
   1. Hold the 1115 in the exact desired location.
   2. Press the tamper switch to send data to the receiver and
      determine if communication is confirmed or faulty. See Figure
      2 for tamper switch and LED locations.
              Confirmed: If communication is confirmed, the survey
              LED turns on when data is sent to the receiver and off




                                                     A
              when acknowledgement is received.
              Faulty: If communication is faulty, the LED remains on
              for about 8 seconds or flashes multiple times in quick
              succession.
   3. Relocate the 1115 or receiver until the LED confirms clear
      communication. Proper communication between the 1115




                                                   IN
      and receiver is verified when for each press or release of
      the tamper switch, the LED blinks immediately on and
      immediately off.
                                                                                         Figure 2: Tamper Switch and
                                                                                                  Survey LED




4
            SET THE DIP SWITCHES
            The 1115 has four DIP switches (labeled 1 through 4) located on the PCB. Cold and flood settings can
            be turned on or off. Hot/warm and freeze/refrigerate are either-or settings. Refer to Table 1 for DIP
                                   M
            switch setting options and operations:


                  DIP SWITCH                       ALARM OCCURS                     ZONE RESTORES
 OPERATION                      CONTACT                                                                           SENSOR
                   POSITION                           WHEN:                            WHEN:

                                           Temperature drops below 45ºF for    Temperature rises above 48ºF
    Cold            1 = ON         1                                                                               Internal
                                                     >10 minutes                     for > 4 minutes
              LI


                                           Temperature rises above 95ºF for     Temperature drops below
     Hot            2 = OFF        2                                                                               Internal
                                                    > 10 minutes                  92ºF for > 4 minutes

                                           Temperature rises above 75ºF for     Temperature drops below
    Warm            2 = ON         2                                                                               Internal
                                                    > 10 minutes                  72ºF for > 4 minutes

                                            Temperature rises above 10°F for   Temperature drops below 7°F
   Freezer          3 = OFF        3                                                                           External (T280R)
                                                    > 30 minutes                     for > 4 minutes
             E




                                           Temperature rises above 42°F for     Temperature drops below
 Refrigerator       3 = ON         3                                                                           External (T280R)
                                                    > 30 minutes                  39°F for > 4 minutes

                                             Probe tips are in contact with     Probe tips have not been in
    Flood           4 = ON         4                                                                           External (470PB)
                                                 water for > 3 minutes             water for > 3 minutes
R




                                       Table 1: DIP Switch Settings and Operation
P




                                1115 INSTALLATION GUIDE     |   DIGITAL MONITORING PRODUCTS 		                                2


5
         WIRE THE SENSOR PROBES (Optional)                                            SENSOR PROBES




                                                    Y
         If freezer or refrigerator sensing functionality is required,
         connect a T280R temperature sensor probe. If flood
                                                                                                             2M EOL Resistor
         sensing functionality is required, connect a 470PB water
sensor probe. When connecting a remote probe to the terminal
                                                                                     Connect to               Connect to
block, DMP recommends using 18 or 22-gauge unshielded wire. Do                                                Terminal F
                                                                                     Terminal C




                                                   R
not use twisted pair or shielded wire.
Connect the 470PB Water Sensor Probe
To use the 470PB, place the probe inside the area and run 18 or
22-gauge unshielded wire to the 1115. Follow these steps to connect
the wire to the 1115 terminals:
   1. Connect a wire from the top of one of the sensor’s probes to                     Figure 3: 470PB Water




                                                  A
      the F terminal on the 1115 PCB by running it through the wiring                       Sensor Probe
      opening in the housing. See Figures 3 and 5.
   2. Connect a wire from the top of the other probe to the C
      terminal on the 1115 PCB by running it through the wire                                   Connect to
                                                                                                Terminal C
      opening in the housing.
   3. Connect a 2M EOL resistor (included with the 1115) between                Connect to




                                                IN
      the two probes.                                                           Terminal T

Connect the T280R Temperature Sensor Probe
To use the T280R, place the probe inside the refrigerator or freezer
environment and run 18 or 22-gauge unshielded wire to the 1115.
Follow these steps to connect the wire to the 1115 terminals:                        Figure 4: T280R Temperature
                                                                                             Sensor Probe
   1. Connect the grey wire to the T terminal on the 1115 PCB
      by running it through the wire opening in the housing. See
      Figures 4 and 5.
   2. Connect the black wire to the C terminal on the 1115 PCB by
                                                                                                      Wire Opening
      running it through the wire opening in the housing.
                                  M
                                                                                                             Optional
                                                                    Terminal Block                           Mounting Hole




6
         MOUNT THE 1115
         It is recommended the sensor be mounted on a flat wall                         T   C     F
         away from large metal objects. Do not mount the 1115 inside
         of freezers or walk-in refrigerators. In those situations, use
            LI


the optional remote T280R temperature probe.
   1. Hold the transmitter base on the wall and place one screw into
      the mounting hole location shown in Figure 5 and secure the
      housing to the surface.
           Note: You can place an additional screw in the optional
           mounting hole if needed.
   2. Snap the transmitter housing cover back on the base.
           E
R




                                                                          Mounting
                                                                             Hole
                                                                                 Figure 5: Mounting Holes
                                                                                    and Terminal Block
P




                              1115 INSTALLATION GUIDE   |   DIGITAL MONITORING PRODUCTS                                    3


REPLACE THE BATTERY




                                                                  Y
    1.    Remove the cover by pushing the button on the end of the cover and gently pulling upwards.
    2.    Remove the old battery and dispose of it properly.
    3.    Observing polarity, place the new battery in the holder and press into place.
    4.    Snap the transmitter housing cover back on the base.
         Caution: Properly dispose of used batteries. Do not recharge, disassemble, heat above 212°F (100°C), or incinerate. Risk of fire,
         explosion, and burns.




                                                                 R
Sensor Reset to Clear LOBAT
When the battery needs to be replaced, a LOBAT message will display on the keypad. Once the battery is replaced, a sensor reset is
required at the system keypad to clear the LOBAT message.
    1. On a Thinline keypad, press and hold “2” for two seconds. On a touchscreen keypad press RESET.
    2. Enter your user code if required.
    3. The keypad displays SENSORS OFF followed by SENSORS ON.




                                                                A
FCC INFORMATION
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
     1. This device may not cause harmful interference, and
     2. this device must accept any interference received, including interference that may cause undesired operation.
The antenna used for this transmitter must be installed to provide a separation distance of at least 20 cm (7.874 in.) from all persons. It
must not be located or operated in conjunction with any other antenna or transmitter.
Changes or modifications made by the user and not expressly approved by the party responsible for compliance could void the user’s
authority to operate the equipment.




                                                              IN
      Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the
      FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
      This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the
      instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not
      occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be
      determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the
      following measures:
             ƒƒ Reorient or relocate the receiving antenna.
             ƒƒ Increase the separation between the equipment and receiver.
             ƒƒ Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
             ƒƒ Consult the dealer or an experienced radio/TV technician for help.
                                                M
Industry Canada Information
This device complies with Industry Canada Licence-exempt RSS standard(s). Operation is subject to the following two conditions:
     1. this device may not cause interference, and
     2. this device must accept any interference, including interference that may cause undesired operation of the device.
Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts de licence. L’exploitation est
autorisée aux deux conditions suivantes : (1) l’appareil ne doit pas produire de brouillage, et (2) l’utilisateur de l’appareil doit accepter
tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en compromettre le fonctionnement.
This system has been evaluated for RF Exposure per RSS-102 and is in compliance with the limits specified by Health Canada Safety
Code 6. The system must be installed at a minimum separation distance from the antenna to a general bystander of 7.87 inches (20 cm)
                  LI


to maintain compliance with the General Population limits.
L’exposition aux radiofréquences de ce système a été évaluée selon la norme RSS-102 et est jugée conforme aux limites établies par le
Code de sécurité 6 de Santé Canada. Le système doit être installé à une distance minimale de 7.87 pouces (20 cm) séparant l’antenne
d’une personne présente en conformité avec les limites permises d’exposition du grand public.



    Specifications                                                Certifications
         Battery                                                       ƒƒ   FCC Part 15 Registration ID CCKPC0192 (pending)
             Life Expectancy    3 Years (normal operation)             ƒƒ   Industry Canada Registration ID 5251A-PC0192 (pending)
                 E




             Type               3.0V Lithium CR123A
         Frequency Range        905-924 MHz
                                                                  Compatibility
                                                                       ƒƒ   1100X Wireless Receiver version 104 or higher
         Dimensions             3.3” L x 1.6” W x 1.2” H               ƒƒ   1100XH Wireless Receiver version 105 or higher
         Color                  White                                  ƒƒ   1100D Wireless Receiver version 104 or higher
                                                                       ƒƒ   1100DI Wireless Receiver Version 105 or higher
         Housing Material       Flame retardant ABS                    ƒƒ   1100DH Wireless Receiver Version 105 or higher
                                                                       ƒƒ   XT50 Series panels with integrated wireless receiver version 101 or higher
    Accessories                                                        ƒƒ   XTL Series panels with integrated wireless receiver version 104 or higher
R




         470PB                  Water Sensor Probe                     ƒƒ   XTLplus Series Panels

         T280R                  Temperature Sensor Probe          Patents
    Replacements                                                       ƒƒ U. S. Patent No. 7,239,236

          ƒƒ CR123A             3.0V Lithium Battery

                                                                     INTRUSION • FIRE • ACCESS • NETWORKS
                                     Designed, engineered,                   2500 North Partnership Boulevard
                                     and manufactured in
P




                                                                              Springfield, Missouri 65803-8877
                                      Springfield, Missouri
                                                                                800-641-4282 | dmp.com



Document Created: 2016-11-16 11:38:45
Document Modified: 2016-11-16 11:38:45

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC