TEST REPORT

FCC ID: CCKPC0152

Test Report

Download: PDF
FCCID_1964130

NVLAP Lab Code 200087-0




                    Application For
                  Grant of Certification
                                                FOR
                                                  FOR


                      Models:
      1127C Wireless PIR, 1127W Wireless PIR
                   902-928 MHz
             Low Power Transmitter
              FCC ID: CCKPC0152
                IC: 5251A-PC0152
                                                  FOR



  Digital Monitoring Products, Inc.
                            2500 North Partnership Boulevard
                              Springfield, MO 65802-6310

                               Test Report Number: 130415

Authorized Signatory:
                            Scot D. Rogers




Rogers Labs, Inc.                 Digital Monitoring Products, Inc.              SN: ENG1
4405 W. 259th Terrace             Models: 1127C Wireless PIR, 1127W Wireless PIR FCC ID#: CCKPC0152
Louisburg, KS 66053               Test #: 130415                                 IC: 5251A-PC0152
Phone/Fax: (913) 837-3214         Test to: CFR47 (15.249), RSS-210               Date: May 10, 2013
Revision 1                        File: DMP 1127CPIR TstRpt 130415               Page 1 of 27


NVLAP Lab Code 200087-0


                             ROGERS LABS, INC.
                             4405 West 259th Terrace
                             Louisburg, KS 66053
                             Phone / Fax (913) 837-3214



                  Engineering Test Report For
                Grant of Certification Application
                                                  FOR
                  CFR 47, PART 15C - Intentional Radiators
             CFR 47 Paragraph 15.249 and Industry Canada RSS-210
                     License Exempt Intentional Radiator
                                                   For


              Digital Monitoring Products, Inc.
                                    2500 North Partnership Boulevard
                                      Springfield, MO 65802-6310

          Models: 1127C Wireless PIR, 1127W Wireless PIR

                                   Low Power Transmitter
                                     Frequency Range 902-928 MHz
                                         FCC ID#: CCKPC0152
                                           IC: 5251A-PC0152

Test Date:       April 15, 2013

Certifying Engineer:
                            Scot D. Rogers
                            Rogers Labs, Inc.
                            4405 West 259th Terrace
                            Louisburg, KS 66053
                            Telephone/Facsimile: (913) 837-3214

This report shall not be reproduced except in full, without the written approval of the laboratory.
This report must not be used by the client to claim product certification, approval, or
endorsement by NVLAP, NIST, or any agency of the Federal Government.
Rogers Labs, Inc.                 Digital Monitoring Products, Inc.              SN: ENG1
4405 W. 259th Terrace             Models: 1127C Wireless PIR, 1127W Wireless PIR FCC ID#: CCKPC0152
Louisburg, KS 66053               Test #: 130415                                 IC: 5251A-PC0152
Phone/Fax: (913) 837-3214         Test to: CFR47 (15.249), RSS-210               Date: May 10, 2013
Revision 1                        File: DMP 1127CPIR TstRpt 130415               Page 2 of 27


NVLAP Lab Code 200087-0

Table Of Contents
TABLE OF CONTENTS ............................................................................................................. 3

REVISIONS ................................................................................................................................... 4

FORWARD.................................................................................................................................... 5

OPINION / INTERPRETATION OF RESULTS ....................................................................... 5

EQUIPMENT TESTED ................................................................................................................ 5

EQUIPMENT FUNCTION AND CONFIGURATION .............................................................. 6

     Equi pment Configuration ................................................................................................................................................... 6

APPLICATION FOR CERTIFICATION .................................................................................... 7

STATEMENT OF MODIFICATIONS AND DEVIATIONS ..................................................... 8

APPLICABLE STANDARDS & TEST PROCEDURES ........................................................ 8

EQUIPMENT TESTING PROCEDURES ................................................................................. 8

     AC Li ne Conducted Emission Test Procedure .............................................................................................................. 8
       Diagram 1 Test arrangement for Conducted emissions ................................................................................................. 9

     Radi ated Emission Test Procedure.................................................................................................................................10
       Diagram 2 Test arrangement for radiated emissions of tabletop equipment ............................................................ 10
       Diagram 3 Test arrangement for radiated emissions tested on Open Area Test Site (OATS) .............................. 11

TEST SITE LOCATIONS.......................................................................................................... 12

UNITS OF MEASUREMENTS................................................................................................. 12

ENVIRONMENTAL CONDITIONS ......................................................................................... 12

LIST OF TEST EQUIPMENT ................................................................................................... 13

INTENTIONAL RADIATORS ................................................................................................... 14

     Antenna Requirements ......................................................................................................................................................14

     Restricted Bands of Operation ........................................................................................................................................14
       Table 1 Radiated Emissions in Restricted Bands Data ................................................................................................ 15

     Summary of Results for Radiated Emissions in Restricted B ands ........................................................................15

     General Radiated Emissions Procedure ........................................................................................................................16
Rogers Labs, Inc.                                    Digital Monitoring Products, Inc.              SN: ENG1
4405 W. 259th Terrace                                Models: 1127C Wireless PIR, 1127W Wireless PIR FCC ID#: CCKPC0152
Louisburg, KS 66053                                  Test #: 130415                                 IC: 5251A-PC0152
Phone/Fax: (913) 837-3214                            Test to: CFR47 (15.249), RSS-210               Date: May 10, 2013
Revision 1                                           File: DMP 1127CPIR TstRpt 130415               Page 3 of 27


NVLAP Lab Code 200087-0

       Table 2 General Radiated Emissions from EUT Data (Highest Emissions) ............................................................ 16

     Summary of Results for General Radi ated Emissions ..............................................................................................16

     Operation in the B and 902-928 MHz .............................................................................................................................17
       Figure 1 Plot of Occupied Bandwidth............................................................................................................................. 18
       Figure 2 Plot of Operation across frequency band........................................................................................................ 18
       Figure 3 Plot of Lo wer Band Edge .................................................................................................................................. 19
       Figure 4 Plot of Upper Band Edge .................................................................................................................................. 19
       Table 3 Transmitter Radiated Emissions........................................................................................................................ 20

     Summary of Results for Radiated Emissions of 902-928 MHz Trans mitter .......................................................21

ANNEX......................................................................................................................................... 22

     Annex A Measurement Uncertainty Calculations ......................................................................................................23

     Annex B Rogers Labs Test Equi pment List.................................................................................................................24

     Annex C Rogers Qualifications .......................................................................................................................................25

     Annex D FCC Site Registration Letter ..........................................................................................................................26

     Annex E Industry Canada Site Registration Letter ..................................................................................................27




 Revisions
Revision 1 Issued May 10, 2013




Rogers Labs, Inc.                                  Digital Monitoring Products, Inc.              SN: ENG1
4405 W. 259th Terrace                              Models: 1127C Wireless PIR, 1127W Wireless PIR FCC ID#: CCKPC0152
Louisburg, KS 66053                                Test #: 130415                                 IC: 5251A-PC0152
Phone/Fax: (913) 837-3214                          Test to: CFR47 (15.249), RSS-210               Date: May 10, 2013
Revision 1                                         File: DMP 1127CPIR TstRpt 130415               Page 4 of 27


NVLAP Lab Code 200087-0


Forward
The following information is submitted for consideration in obtaining Grant of Certification for
low power intentional radiator per CFR 47 Paragraph 15.249, and Industry Canada RSS-210,
operation in the 902-928 MHz band.

        Name of Applicant:   Digital Monitoring Products, Inc.
                             2500 North Partnership Boulevard
                             Springfield, MO 65802-6310
        Models: 1127C Wireless PIR, 1127W Wireless PIR
        FCC I.D.: CCKPC0152                 Industry Canada ID: 5251A-PC0152
        Frequency Range: 903- 927 MHz
        Operating power: maximum average power 48.6 dBµV/m @ 3 meters (and peak 103.1
                         dBµV/m @ 3 meters), 6-dB occupied bandwidth 148.0 kHz
Opinion / Interpretation of Results
                        Tests Performed                           Margin (dB)         Results

 Emissions as per CFR 47 paragraphs 2 and 15.205                      -55.6          Complies

 Emissions as per CFR 47 paragraphs 2 and 15.207                       N/A           Complies

 Emissions as per CFR 47 paragraphs 2 and 15.209                       -7.3          Complies

 Harmonic Emissions per CFR 47 15.249                                 -45.1          Complies



Equipment Tested
Equipment                   Model / PN                          Serial Number

EUT                         1127C Wireless PIR                  ENG1

Test results in this report relate only to the items tested.




Rogers Labs, Inc.                 Digital Monitoring Products, Inc.              SN: ENG1
4405 W. 259th Terrace             Models: 1127C Wireless PIR, 1127W Wireless PIR FCC ID#: CCKPC0152
Louisburg, KS 66053               Test #: 130415                                 IC: 5251A-PC0152
Phone/Fax: (913) 837-3214         Test to: CFR47 (15.249), RSS-210               Date: May 10, 2013
Revision 1                        File: DMP 1127CPIR TstRpt 130415               Page 5 of 27


NVLAP Lab Code 200087-0

Equipment Function and Configuration
The EUT is a 902-928 MHz low power radio transmitter providing wireless interface with alarm
panel installation for control and function. The equipment performs Pass Infra-Red (PIR)
detection and transmits alarm code wirelessly for use in fire/premises alarm system. The unit is
marketed for use to incorporate a wireless link in the alarm system solution. The design operates
from direct current power only and offers no provision for connection to utility power systems.
New 3-volt lithium batteries were used to power the EUT during testing. As requested by the
manufacturer and required by regulations, the equipment was tested for emissions compliance
using the available configurations with the worst-case data presented. Test results in this report
relate only to the products described in this report.

Equipment Configuration




                    EUT




Rogers Labs, Inc.              Digital Monitoring Products, Inc.              SN: ENG1
4405 W. 259th Terrace          Models: 1127C Wireless PIR, 1127W Wireless PIR FCC ID#: CCKPC0152
Louisburg, KS 66053            Test #: 130415                                 IC: 5251A-PC0152
Phone/Fax: (913) 837-3214      Test to: CFR47 (15.249), RSS-210               Date: May 10, 2013
Revision 1                     File: DMP 1127CPIR TstRpt 130415               Page 6 of 27


NVLAP Lab Code 200087-0

Application for Certification
(1)     Manufacturer:          Digital Monitoring Products, Inc.
                               2500 North Partnership Boulevard
                               Springfield, MO 65802-6310

(2)     Identification:        Models: 1127C Wireless PIR, 1127W Wireless PIR

        FCC I.D.: CCKPC0152                    IC ID: 5251A-PC0152

(3)     Instruction Book:

        Refer to Exhibit for Instruction Manual.

(4)     Description of Circuit Functions:

        Refer to Exhibit of Operational Description.

(5)     Block Diagram with Frequencies:

        Refer to Exhibit of Operational Description.

(6)     Report of Measurements:

        Report of measurements follows in this Report.

(7)     Photographs: Construction, Component Placement, etc.:

        Refer to Exhibit for photographs of equipment.

(8)     List of Peripheral Equipment Necessary for operation. The equipment operates from DC
        power supplied from internal battery only as documented in this report. The EUT offers no
        other connection ports than those presented.

(9)     Transition Provisions of CFR47 15.37 are not requested.

(10)    Not Applicable. The unit is not a scanning receiver.

(11)    Not Applicable. The EUT does not operate in the 59 – 64 GHz frequency band.

(12)    The equipment is not software defined and this section is not applicable.




Rogers Labs, Inc.              Digital Monitoring Products, Inc.              SN: ENG1
4405 W. 259th Terrace          Models: 1127C Wireless PIR, 1127W Wireless PIR FCC ID#: CCKPC0152
Louisburg, KS 66053            Test #: 130415                                 IC: 5251A-PC0152
Phone/Fax: (913) 837-3214      Test to: CFR47 (15.249), RSS-210               Date: May 10, 2013
Revision 1                     File: DMP 1127CPIR TstRpt 130415               Page 7 of 27


NVLAP Lab Code 200087-0

Statement of Modifications and Deviations
No modifications to the EUT were required for the unit to demonstrate compliance with the
CFR47 Part 15C and RSS-210 requirements. There were no modifications or deviations to the
specifications.


Applicable Standards & Test Procedures
In accordance with the Federal Communications Commission and Code of Federal Regulations
CFR 47, dated October 1, 2012, Part 2, Subpart J, Paragraphs 2.907, 2.911, 2.913, 2.925, 2.926,
2.1031 through 2.1057, applicable parts of paragraph 15, Part 15C paragraphs 15.225, 15.249,
and Industry Canada RSS-210, the following information is submitted. Test procedures used are
the established Methods of Measurement of Radio-Noise Emissions as described in the ANSI
C63.4-2009 Document.


Equipment Testing Procedures
AC Line Conducted Emission Test Procedure

The EUT operates solely from direct current power and offers no provision for connection to utility
AC power systems. Therefore, no AC power line conducted emissions test was required or
performed. If required, the manufacturer supplied AC connection would be used to power the EUT.
Testing for the AC line-conducted emissions testing would be performed as defined in sections 7 and
13.1.3 of ANSI C63.4-2009. The test setup including the EUT would be arranged in typical
equipment configurations and placed on a 1 x 1.5-meter wooden bench, 0.8 meters high located in a
screen room. The power lines of the system would be isolated from the power source using a
standard LISN with a 50-µHy choke. EMI was coupled to the spectrum analyzer through a 0.1 µF
capacitor internal to the LISN. The LISN would be positioned on the floor beneath the wooden
bench supporting the EUT. The power lines and cables would be draped over the back edge of the
table. Refer to diagram 1 showing typical test arrangement and photographs in the test setup
exhibits for specific EUT placement during testing.




Rogers Labs, Inc.             Digital Monitoring Products, Inc.              SN: ENG1
4405 W. 259th Terrace         Models: 1127C Wireless PIR, 1127W Wireless PIR FCC ID#: CCKPC0152
Louisburg, KS 66053           Test #: 130415                                 IC: 5251A-PC0152
Phone/Fax: (913) 837-3214     Test to: CFR47 (15.249), RSS-210               Date: May 10, 2013
Revision 1                    File: DMP 1127CPIR TstRpt 130415               Page 8 of 27


NVLAP Lab Code 200087-0




Diagram 1 Test arrangement for Conducted emissions
1. Interconnecting cables that hang closer than 40 cm to the ground plane were folded back and
   forth in the center forming a bundle 30 cm to 40 cm long.
2. Input/output (I/O) cables that are not connected to a peripheral shall be bundled in the center.
   The end of the cable may be terminated, if required, using the correct terminating impedance.
   The overall length shall not exceed 1 m.
3. EUT connected to one LISN. Unused LISN measuring port connectors are terminated into 50
   Ω loads. LISN is placed on top of and bonded to reference ground plane.
3.1 All other equipment powered from additional LISN(s).
3.2 Multiple outlet strips can be used for multiple power cords of non-EUT equipment.
3.3 LISN is positioned at least 80 cm from nearest part of EUT chassis.
4. Cables of hand-operated devices, such as keyboards, mice, and so on, shall be placed as for
   normal use.
5. Non-EUT components of EUT system being tested.
6. Rear of EUT, including peripherals, shall all be aligned and flush with rear of tabletop.
7. Rear of tabletop shall be 40 cm removed from a vertical conducting plane that is bonded to the
   ground plane (see 5.2.2 for options).

Rogers Labs, Inc.             Digital Monitoring Products, Inc.              SN: ENG1
4405 W. 259th Terrace         Models: 1127C Wireless PIR, 1127W Wireless PIR FCC ID#: CCKPC0152
Louisburg, KS 66053           Test #: 130415                                 IC: 5251A-PC0152
Phone/Fax: (913) 837-3214     Test to: CFR47 (15.249), RSS-210               Date: May 10, 2013
Revision 1                    File: DMP 1127CPIR TstRpt 130415               Page 9 of 27


NVLAP Lab Code 200087-0

Radiated Emission Test Procedure

The EUT was placed on a rotating 1 x 1.5-meter wooden platform, 0.8 meters above the ground
plane at a distance of 3 meters from the FSM antenna. Radiated emissions testing was
performed as required in CFR47 15, RSS-210 and specified in sections 8 and 13.1.4 of ANSI
C63.4-2009. EMI energy was maximized by equipment placement, raising and lowering the
FSM antenna, changing the antenna polarization, and by rotating the turntable. Each emission
was maximized before data was taken using a spectrum analyzer. The frequency spectrum from
9 kHz to 25,000 MHz was searched for during preliminary investigation. Refer to diagrams 2
and 3 showing typical test arrangement and photographs in the test setup exhibits for specific
EUT placement during testing.




Diagram 2 Test arrangement for radiated emissions of tabletop equipment

Rogers Labs, Inc.             Digital Monitoring Products, Inc.              SN: ENG1
4405 W. 259th Terrace         Models: 1127C Wireless PIR, 1127W Wireless PIR FCC ID#: CCKPC0152
Louisburg, KS 66053           Test #: 130415                                 IC: 5251A-PC0152
Phone/Fax: (913) 837-3214     Test to: CFR47 (15.249), RSS-210               Date: May 10, 2013
Revision 1                    File: DMP 1127CPIR TstRpt 130415               Page 10 of 27


NVLAP Lab Code 200087-0

1. Interconnecting cables that hang closer than 40 cm to the ground plane shall be folded back
   and forth in the center, forming a bundle 30 cm to 40 cm long.
2. I/O cables that are not connected to a peripheral shall be bundled in the center. The end of the
   cable may be terminated if required using the correct terminating impedance. The total length
   shall not exceed 1 m.
3. If LISNs are kept in the test setup for radiated emissions, it is preferred that they be installed
   under the ground plane with the receptacle flush with the ground plane.
4. Cables of hand-operated devices, such as keyboards, mice, and so on, shall be placed as for
   normal use.
5. Non-EUT components of EUT system being tested.
6. Rear of EUT, including peripherals, shall all be aligned and flush with rear of tabletop
   (possibly center of table for transmitter equipment).
7. No vertical conducting plane used.
8. Power cords drape to the floor and are routed over to receptacle.




Diagram 3 Test arrangement for radiated emissions tested on Open Area Test Site (OATS)

Rogers Labs, Inc.              Digital Monitoring Products, Inc.              SN: ENG1
4405 W. 259th Terrace          Models: 1127C Wireless PIR, 1127W Wireless PIR FCC ID#: CCKPC0152
Louisburg, KS 66053            Test #: 130415                                 IC: 5251A-PC0152
Phone/Fax: (913) 837-3214      Test to: CFR47 (15.249), RSS-210               Date: May 10, 2013
Revision 1                     File: DMP 1127CPIR TstRpt 130415               Page 11 of 27


NVLAP Lab Code 200087-0

Test Site Locations
Conducted EMI               The AC power line conducted emissions testing performed in a shielded
                            screen room located at Rogers Labs, Inc., 4405 W. 259 th Terrace,
                            Louisburg, KS

Radiated EMI                The radiated emissions tests were performed at the 3 meters, Open Area
                            Test Site (OATS) located at Rogers Labs, Inc., 4405 W. 259 th Terrace,
                            Louisburg, KS

Site Registration           Refer to Annex for Site Registration Letters

NVLAP Accreditation                Lab code 200087-0


Units of Measurements
Conducted EMI               Data is in dBµV; dB referenced to one microvolt

Radiated EMI                Data is in dBµV/m; dB/m referenced to one microvolt per meter

Sample Calculation:
                RFS = Radiated Field Strength, FSM = Field Strength Measured
                A.F. = Receive antenna factor, Gain = amplification gains and/or cable losses
                RFS (dBµV/m @ 3m) = FSM (dBµV) + A.F. (dB) - Gain (dB)


Environmental Conditions
        Ambient Temperature                 21.3° C

        Relative Humidity                   32%

        Atmospheric Pressure                1015.8 mb




Rogers Labs, Inc.                  Digital Monitoring Products, Inc.              SN: ENG1
4405 W. 259th Terrace              Models: 1127C Wireless PIR, 1127W Wireless PIR FCC ID#: CCKPC0152
Louisburg, KS 66053                Test #: 130415                                 IC: 5251A-PC0152
Phone/Fax: (913) 837-3214          Test to: CFR47 (15.249), RSS-210               Date: May 10, 2013
Revision 1                         File: DMP 1127CPIR TstRpt 130415               Page 12 of 27


NVLAP Lab Code 200087-0

List of Test Equipment
A Rohde and Schwarz ESU40 and/or Hewlett Packard 8591EM was used as the measuring device
for the emissions testing of frequencies below 1 GHz. A Rohde and Schwarz ESU40 and/or
Hewlett Packard 8562A Spectrum Analyzer was used as the measuring device for testing the
emissions at frequencies above 1 GHz. The analyzer settings used are described in the following
table. Refer to the appendix for a complete list of test equipment.



                        AC Line Conducted Emissions (0.150 -30 MHz)
               RBW                         AVG. BW                    Detector Function
               9 kHz                         30 kHz                   Peak / Quasi Peak
                                  Emissions (30-1000 MHz)
               RBW                         AVG. BW                    Detector Function
             120 kHz                        300 kHz                   Peak / Quasi Peak
                                 Emissions (Above 1000 MHz)
               RBW                         Video BW                   Detector Function
             100 kHz                        100 kHz                         Peak
              1 MHz                          1 MHz                     Peak / Average

Equipment       Manufacturer     Model                         Band        Cal Date         Due
   LISN         Comp. Design FCC-LISN-2-MOD.CD                 .15-30MHz 10/12             10/13
   Antenna      ARA              BCD-235-B                     20-350MHz 10/12             10/13
   Antenna      EMCO             3147                          200-1000MHz 10/12           10/13
   Antenna      Com Power        AH-118                        1-18 GHz    10/12           10/13
   Antenna      Com Power        AH-840                        18-40 GHz   10/12           10/13
   Antenna      Sunol            JB-6                          30-1000 MHz 10/12           10/13
   Antenna      EMCO             6509                          .001-30 MHz 10/12           10/13
   Amplifier    Com-Power        PA-010                        100Hz-30MHz 10/12           10/13
   Amplifier    Com-Power        CPPA-102                      1-1000 MHz 10/12            10/13
   Amplifier    Com-Power        PA-22                         0.5-22 GHz 10/12            10/13
   Antenna      Standard         FXRY638A                      10-18 GHz   3/12            5/13
   Antenna      EMCO             3143                          20-1200 MHz 5/12            5/13
   Analyzer     HP               8591EM                        9kHz-1.8GHz 5/12            5/13
   Analyzer     HP               8562A                         9kHz-110GHz 5/12            5/13
   Analyzer     Rohde & Schwarz  ESU40                         20Hz-40GHz 5/12             5/13
Rogers Labs, Inc.              Digital Monitoring Products, Inc.              SN: ENG1
4405 W. 259th Terrace          Models: 1127C Wireless PIR, 1127W Wireless PIR FCC ID#: CCKPC0152
Louisburg, KS 66053            Test #: 130415                                 IC: 5251A-PC0152
Phone/Fax: (913) 837-3214      Test to: CFR47 (15.249), RSS-210               Date: May 10, 2013
Revision 1                     File: DMP 1127CPIR TstRpt 130415               Page 13 of 27


NVLAP Lab Code 200087-0

Intentional Radiators
As per CFR47, Subpart C, paragraph 15.249 and RSS-210 the following information is submitted.

Antenna Requirements

The EUT incorporates integral antenna system and offers no provision for connection to alternate
system. The antenna connection point complies with the unique antenna connection requirements.
The unique antenna connection requirements are fulfilled. There are no deviations or exceptions to
the specification.

Restricted Bands of Operation
Spurious emissions falling in the restricted frequency bands of operation were measured at the
OATS. The EUT utilizes frequency, determining circuitry, which generates harmonics falling in
the restricted bands. Emissions were investigated at the OATS, using appropriate antennas or
pyramidal horns, amplification stages, and a spectrum analyzer. Peak and average amplitudes of
frequencies above 1000 MHz were compared to the required limits with worst-case data
presented below. Test procedures of ANSI C63.4-2009 paragraphs 13.1 and 8.3.1.2 were used
during testing. No other significant emission was observed which fell into the restricted bands of
operation. Computed emission values take into account the received radiated field strength,
receive antenna correction factor, amplifier gain stage, and test system cable losses.




Rogers Labs, Inc.             Digital Monitoring Products, Inc.              SN: ENG1
4405 W. 259th Terrace         Models: 1127C Wireless PIR, 1127W Wireless PIR FCC ID#: CCKPC0152
Louisburg, KS 66053           Test #: 130415                                 IC: 5251A-PC0152
Phone/Fax: (913) 837-3214     Test to: CFR47 (15.249), RSS-210               Date: May 10, 2013
Revision 1                    File: DMP 1127CPIR TstRpt 130415               Page 14 of 27


NVLAP Lab Code 200087-0

Table 1 Radiated Emissions in Restricted Bands Data
   Frequency in   Horizontal   Horizontal   Horizontal    Vertical    Vertical     Vertical   Limit @ 3m
      M Hz          Peak       Quasi-Peak    Average       Peak      Quasi-Peak    Average     (dBµV/m)
                  (dBµV/m)     (dBµV/m)     (dBµV/m)     (dBµV/m)    (dBµV/m)     (dBµV/m)

     150.0          24.5         19.3         N/A          20.3        15.2         N/A         43.5

     2710.0         40.0         N/A         -23.3         45.2        N/A         -16.6        54.0

     2746.4         39.6         N/A         -23.8         42.5        N/A         -19.9        54.0

     2780.0         34.9         N/A         -30.1         41.8        N/A         -20.9        54.0

     3613.3         42.8         N/A         -19.3         40.4        N/A         -22.9        54.0

     3661.8         44.5         N/A         -18.0         42.2        N/A         -20.7        54.0

     3706.7         41.0         N/A         -21.6         41.6        N/A         -21.2        54.0

     4516.6         47.0         N/A         -15.0         46.3        N/A         -15.7        54.0

     4577.3         45.9         N/A         -16.4         43.6        N/A         -19.3        54.0

     4633.4         44.7         N/A         -17.5         42.7        N/A         -20.3        54.0

     5419.9         59.4         N/A          -1.6         44.5        N/A         -19.3        54.0

     7323.6         50.2         N/A         -11.9         45.7        N/A         -17.1        54.0

     7413.4         52.5         N/A          -9.1         50.0        N/A         -11.9        54.0
Other emissions present had amplitudes at least 20 dB below the limit. Peak and Quasi-Peak
amplitude emissions recorded for frequency range below 1000 MHz. Peak and Average
amplitude emissions recorded for frequency range above 1000 MHz.

Summary of Results for Radiated Emissions in Restricted Bands

The EUT demonstrated compliance with the radiated emissions requirements of CFR 47 Part
15C and RSS-210 Intentional Radiators. The EUT demonstrated a worst-case minimum margin
of -24.2 dB below the radiated emissions requirements in restricted frequency bands. Peak,
Quasi-peak, and average amplitudes were checked for compliance with the regulations. Worst-
case emissions are reported with other emissions found in the restricted frequency bands at least
20 dB below the requirements.



Rogers Labs, Inc.                  Digital Monitoring Products, Inc.              SN: ENG1
4405 W. 259th Terrace              Models: 1127C Wireless PIR, 1127W Wireless PIR FCC ID#: CCKPC0152
Louisburg, KS 66053                Test #: 130415                                 IC: 5251A-PC0152
Phone/Fax: (913) 837-3214          Test to: CFR47 (15.249), RSS-210               Date: May 10, 2013
Revision 1                         File: DMP 1127CPIR TstRpt 130415               Page 15 of 27


NVLAP Lab Code 200087-0

General Radiated Emissions Procedure

The EUT was arranged in a typical equipment configuration and operated through all available
modes with worst-case data recorded. Preliminary testing was performed in a screen room with
the EUT positioned 1 meter from the FSM. Radiated emissions measurements were performed
to identify frequencies, which produced the highest emissions. Each radiated emission was then
maximized at the OATS location before final radiated emissions measurements were performed.
Final data was taken with the EUT located at the OATS at a distance of 3 meters between the
EUT and the receiving antenna. The frequency spectrum from 9 kHz to 10,000 MHz was
searched for general radiated emissions. Measured emission levels were maximized by EUT
placement on the table, rotating the turntable through 360 degrees, varying the antenna height
between 1 and 4 meters above the ground plane and changing antenna position between
horizontal and vertical polarization. Antennas used were Loop from 9 kHz to 30 MHz,
Broadband Biconical from 30 to 200 MHz, Biconilog from 30 to 1000 MHz, Log Periodic from
200 MHz to 1 GHz and or double Ridge or pyramidal horns and mixers from 1 GHz to 40 GHz,
notch filters and appropriate amplifiers and external mixers were utilized.

Table 2 General Radiated Emissions from EUT Data (Highest Emissions)
  Frequency     Horizontal   Horizontal   Horizontal    Vertical    Vertical     Vertical   Limit @ 3m
    in MHz        Peak       Quasi-Peak    Average       Peak      Quasi-Peak    Average    (dBµV/m)
                (dBµV/m)     (dBµV/m)     (dBµV/m)     (dBµV/m)    (dBµV/m)     (dBµV/m)

    150.0         24.5         19.3         N/A          20.3        15.2         N/A         43.5

    759.0         34.1         32.4         N/A          37.6        36.3         N/A         46.0

    811.0         30.9         28.3         N/A          40.4        38.7         N/A         46.0

    863.4         29.3         25.8         N/A          43.0        41.6         N/A         46.0
Other emissions present had amplitudes at least 20 dB below the limit. Peak and Quasi-Peak
amplitude emissions recorded for frequency range below 1000 MHz. Peak and Average
amplitude emissions recorded for frequency range above 1000 MHz.
Summary of Results for General Radiated Emissions
The EUT demonstrated compliance with the radiated emissions requirements of CFR47 Part 15C
paragraph 15.209 and RSS-210 Intentional Radiators. The EUT demonstrated a minimum
margin of -7.3 dB below the requirements. Other emissions were present with amplitudes at
least 20 dB below the Limits.
Rogers Labs, Inc.                Digital Monitoring Products, Inc.              SN: ENG1
4405 W. 259th Terrace            Models: 1127C Wireless PIR, 1127W Wireless PIR FCC ID#: CCKPC0152
Louisburg, KS 66053              Test #: 130415                                 IC: 5251A-PC0152
Phone/Fax: (913) 837-3214        Test to: CFR47 (15.249), RSS-210               Date: May 10, 2013
Revision 1                       File: DMP 1127CPIR TstRpt 130415               Page 16 of 27


NVLAP Lab Code 200087-0

Operation in the Band 902-928 MHz

The transmitter output power; harmonic and general emissions were measured on an open area
test site @ 3 meters. Test procedures of ANSI C63.4-2009 paragraphs 13.1 and 8.3.1.2 were
used during testing. The EUT was placed on a wooden turntable 0.8 meters above the ground
plane and at a distance of 3 meters from the FSM antenna. The peak and quasi-peak amplitude
of frequencies below 1000 MHz were measured using a spectrum analyzer. The peak and
average amplitude of frequencies above 1000 MHZ were measured using a spectrum analyzer.
The amplitude of each emission was then recorded from the analyzer display. Emissions
radiated outside of the specified bands, except for harmonics, shall be attenuated by at least 50
dB below the level of the fundamental or to the general radiated emission limits in 15.209,
whichever is the lesser attenuation. Plots were taken of transmitter performance for reference in
this and other documentation. Refer to figures one through four showing the frequency and
amplitude of worst-case emissions as displayed on the spectrum analyzer. The amplitude of each
radiated emission was measured on the OATS at a distance of 3 meters from the FSM antenna
(testing was performed on sample 1 representative of production with integral antenna). The
amplitude of each radiated emission was maximized by varying the FSM antenna height,
polarization, and by rotating the turntable. A Loop antenna was used for measuring emissions
from 0.009 to 30 MHz, Biconilog Antenna for 30 to 1000 MHz, Double-Ridge, and/or Pyramidal
Horn Antennas from 1 GHz to 25 GHz. Emissions were measured in dBµV/m @ 3 meters.

The transmitter operates at a duty cycle of 0.19 mS operation in a 100 mS frame. This duty
cycle operation provides for duty cycle reduction of measured average emission levels. The
average emission levels measured and recorded were corrected by reducing the measured level
by -54.4 dB for comparison to average limits. Note: Peak amplitudes are not reduced or
corrected, as duty cycle does not reduce peak amplitude.

Duty Cycle correction = 20*log (0.19/100) = -54.4 dB




Rogers Labs, Inc.             Digital Monitoring Products, Inc.              SN: ENG1
4405 W. 259th Terrace         Models: 1127C Wireless PIR, 1127W Wireless PIR FCC ID#: CCKPC0152
Louisburg, KS 66053           Test #: 130415                                 IC: 5251A-PC0152
Phone/Fax: (913) 837-3214     Test to: CFR47 (15.249), RSS-210               Date: May 10, 2013
Revision 1                    File: DMP 1127CPIR TstRpt 130415               Page 17 of 27


NVLAP Lab Code 200087-0




Figure 1 Plot of Occupied Bandwidth




Figure 2 Plot of Operation across frequency band


Rogers Labs, Inc.           Digital Monitoring Products, Inc.              SN: ENG1
4405 W. 259th Terrace       Models: 1127C Wireless PIR, 1127W Wireless PIR FCC ID#: CCKPC0152
Louisburg, KS 66053         Test #: 130415                                 IC: 5251A-PC0152
Phone/Fax: (913) 837-3214   Test to: CFR47 (15.249), RSS-210               Date: May 10, 2013
Revision 1                  File: DMP 1127CPIR TstRpt 130415               Page 18 of 27


NVLAP Lab Code 200087-0




Figure 3 Plot of Lower Band Edge




Figure 4 Plot of Upper Band Edge


Rogers Labs, Inc.           Digital Monitoring Products, Inc.              SN: ENG1
4405 W. 259th Terrace       Models: 1127C Wireless PIR, 1127W Wireless PIR FCC ID#: CCKPC0152
Louisburg, KS 66053         Test #: 130415                                 IC: 5251A-PC0152
Phone/Fax: (913) 837-3214   Test to: CFR47 (15.249), RSS-210               Date: May 10, 2013
Revision 1                  File: DMP 1127CPIR TstRpt 130415               Page 19 of 27


NVLAP Lab Code 200087-0

Table 3 Transmitter Radiated Emissions
   Frequency in   Horizontal   Horizontal   Horizontal    Vertical    Vertical     Vertical   Limit @ 3m
      M Hz          Peak       Quasi-Peak    Average       Peak      Quasi-Peak    Average     (dBµV/m)
                  (dBµV/m)     (dBµV/m)     (dBµV/m)     (dBµV/m)    (dBµV/m)     (dBµV/m)

     903.3          93.5         38.9         N/A         103.1        48.6         N/A         94.0

     1806.6         60.7         N/A           0.9         67.6        N/A          8.9         54.0

     2710.0         40.0         N/A         -23.3         45.2        N/A         -16.6        54.0

     3613.3         42.8         N/A         -19.3         40.4        N/A         -22.9        54.0

     4516.6         47.0         N/A         -15.0         46.3        N/A         -15.7        54.0

     5419.9         59.4         N/A          -1.6         44.5        N/A         -19.3        54.0

     915.5          90.0         35.4         N/A         103.1        48.6         N/A         94.0

     1830.9         58.5         N/A          -0.2         64.7        N/A          6.1         54.0

     2746.4         39.6         N/A         -23.8         42.5        N/A         -19.9        54.0

     3661.8         44.5         N/A         -18.0         42.2        N/A         -20.7        54.0

     4577.3         45.9         N/A         -16.4         43.6        N/A         -19.3        54.0

     5492.7         60.7         N/A           0.3         50.3        N/A         -11.2        54.0

     926.7          89.9         34.7         N/A         101.1        46.6         N/A         94.0

     1853.4         57.1         N/A          -1.8         62.8        N/A          4.1         54.0

     2780.0         34.9         N/A         -30.1         41.8        N/A         -20.9        54.0

     3706.7         41.0         N/A         -21.6         41.6        N/A         -21.2        54.0

     4633.4         44.7         N/A         -17.5         42.7        N/A         -20.3        54.0

     5560.1         61.0         N/A           0.2         53.0        N/A          -8.2        54.0
Other emissions present had amplitudes at least 20 dB below the limit. Peak and Quasi-Peak
amplitude emissions recorded for frequency range below 1000 MHz. Peak and Average
amplitude emissions recorded for frequency range above 1000 MHz.




Rogers Labs, Inc.                  Digital Monitoring Products, Inc.              SN: ENG1
4405 W. 259th Terrace              Models: 1127C Wireless PIR, 1127W Wireless PIR FCC ID#: CCKPC0152
Louisburg, KS 66053                Test #: 130415                                 IC: 5251A-PC0152
Phone/Fax: (913) 837-3214          Test to: CFR47 (15.249), RSS-210               Date: May 10, 2013
Revision 1                         File: DMP 1127CPIR TstRpt 130415               Page 20 of 27


NVLAP Lab Code 200087-0

Summary of Results for Radiated Emissions of 902-928 MHz Transmitter

The EUT demonstrated compliance with the radiated emissions requirements of FCC CFR 47
Part 15.249, RSS-210 and other applicable standards for Intentional Radiators. The EUT worst-
case configuration demonstrated average emission minimum margin of -45.4 dB below the
average emission limit. The EUT worst-case configuration demonstrated minimum radiated
harmonic emission margin of -45.1 dB below the limits. Other emissions were present with
amplitudes at least 20 dB below the limits.




Rogers Labs, Inc.             Digital Monitoring Products, Inc.              SN: ENG1
4405 W. 259th Terrace         Models: 1127C Wireless PIR, 1127W Wireless PIR FCC ID#: CCKPC0152
Louisburg, KS 66053           Test #: 130415                                 IC: 5251A-PC0152
Phone/Fax: (913) 837-3214     Test to: CFR47 (15.249), RSS-210               Date: May 10, 2013
Revision 1                    File: DMP 1127CPIR TstRpt 130415               Page 21 of 27


NVLAP Lab Code 200087-0

Annex
   Annex A Measurement Uncertainty Calculations

   Annex B Rogers Labs Test Equipment List

   Annex C Rogers Qualifications

   Annex D FCC Site Registration Letter

   Annex E Industry Canada Site Registration Letter




Rogers Labs, Inc.            Digital Monitoring Products, Inc.              SN: ENG1
4405 W. 259th Terrace        Models: 1127C Wireless PIR, 1127W Wireless PIR FCC ID#: CCKPC0152
Louisburg, KS 66053          Test #: 130415                                 IC: 5251A-PC0152
Phone/Fax: (913) 837-3214    Test to: CFR47 (15.249), RSS-210               Date: May 10, 2013
Revision 1                   File: DMP 1127CPIR TstRpt 130415               Page 22 of 27


NVLAP Lab Code 200087-0

Annex A Measurement Uncertainty Calculations

Measurement uncertainty calculations were made for the laboratory. Result of measurement
uncertainty calculations are recorded below for AC line conducted and radiated emission
measurements.

Measurement Uncertainty                                         U(E)               U(lab)

3 Meter Horizontal 30-200 MHz Measurements                      2.08                4.16

3 Meter Vertical 30-200 MHz Measurements                        2.16                4.33

3 Meter Vertical Measurements 200-1000 MHz                      2.99                5.97

10 Meter Horizontal Measurements 30-200 MHz                     2.07                4.15

10 Meter Vertical Measurements 30-200 MHz                       2.06                4.13

10 Meter Horizontal Measurements 200-1000 MHz                   2.32                4.64

10 Meter Vertical Measurements 200-1000 MHz                     2.33                4.66

3 Meter Measurements 1-6 GHz                                    2.57                5.14

3 Meter Measurements 6-18 GHz                                   2.58                5.16

AC Line Conducted                                               1.72                3.43




Rogers Labs, Inc.            Digital Monitoring Products, Inc.              SN: ENG1
4405 W. 259th Terrace        Models: 1127C Wireless PIR, 1127W Wireless PIR FCC ID#: CCKPC0152
Louisburg, KS 66053          Test #: 130415                                 IC: 5251A-PC0152
Phone/Fax: (913) 837-3214    Test to: CFR47 (15.249), RSS-210               Date: May 10, 2013
Revision 1                   File: DMP 1127CPIR TstRpt 130415               Page 23 of 27


NVLAP Lab Code 200087-0


Annex B Rogers Labs Test Equipment List
List of Test Equipment                                            Calibration Date
Spectrum Analyzer: Rohde & Schwarz ESU40                                  5/12
Spectrum Analyzer: HP 8562A, HP Adapters: 11518, 11519, and 11520         5/12
        Mixers: 11517A, 11970A, 11970K, 11970U, 11970V, 11970W
Spectrum Analyzer: HP 8591EM                                              5/12
Antenna: EMCO Biconilog Model: 3143                                       5/12
Antenna: Sunol Biconilog Model: JB6                                       10/12
Antenna: EMCO Log Periodic Model: 3147                                    10/12
Antenna: Com Power Model: AH-118                                          10/12
Antenna: Com Power Model: AH-840                                          10/12
Antenna: Antenna Research Biconical Model: BCD 235                        10/12
LISN: Compliance Design Model: FCC-LISN-2.Mod.cd, 50 μHy/50 ohm/0.1 µf 10/12
R.F. Preamp CPPA-102                                                      10/12
Attenuator: HP Model: HP11509A                                            10/12
Attenuator: Mini Circuits Model: CAT-3                                    10/12
Attenuator: Mini Circuits Model: CAT-3                                    10/12
Cable: Belden RG-58 (L1)                                                  10/12
Cable: Belden RG-58 (L2)                                                  10/12
Cable: Belden 8268 (L3)                                                   10/12
Cable: Time Microwave: 4M-750HF290-750                                    10/12
Cable: Time Microwave: 10M-750HF290-750                                   10/12
Antenna: EMCO 6509                                                        10/12
Frequency Counter: Leader LDC825                                          2/13
Oscilloscope Scope: Tektronix 2230                                        2/13
Wattmeter: Bird 43 with Load Bird 8085                                    2/13
Power Supplies: Sorensen SRL 20-25, SRL 40-25, DCR 150, DCR 140           2/13
R.F. Generators: HP 606A, HP 8614A, HP 8640B                              2/13
R.F. Power Amp 65W Model: 470-A-1010                                      2/13
R.F. Power Amp 50W M185- 10-501                                           2/13
R.F. Power Amp A.R. Model: 10W 1010M7                                     2/13
R.F. Power Amp EIN Model: A301                                            2/13
LISN: Compliance Eng. Model 240/20                                        2/13
LISN: Fischer Custom Communications Model: FCC-LISN-50-16-2-08            2/13
Antenna: EMCO Dipole Set 3121C                                            2/13
Antenna: C.D. B-101                                                       2/13
Antenna: Solar 9229-1 & 9230-1                                            2/13
Audio Oscillator: H.P. 201CD                                              2/13
ELGAR Model: 1751                                                         2/13
ELGAR Model: TG 704A-3D                                                   2/13
ESD Test Set 2010i                                                        2/13
Fast Transient Burst Generator Model: EFT/B-101                           2/13
Field Intensity Meter: EFM-018                                            2/13
KEYTEK Ecat Surge Generator                                               2/13
Shielded Room 5 M x 3 M x 3.0 M

Rogers Labs, Inc.           Digital Monitoring Products, Inc.              SN: ENG1
4405 W. 259th Terrace       Models: 1127C Wireless PIR, 1127W Wireless PIR FCC ID#: CCKPC0152
Louisburg, KS 66053         Test #: 130415                                 IC: 5251A-PC0152
Phone/Fax: (913) 837-3214   Test to: CFR47 (15.249), RSS-210               Date: May 10, 2013
Revision 1                  File: DMP 1127CPIR TstRpt 130415               Page 24 of 27


NVLAP Lab Code 200087-0


Annex C Rogers Qualifications

Scot D. Rogers, Engineer

Rogers Labs, Inc.

Mr. Rogers has approximately 17 years’ experience in the field of electronics. Engineering
experience includes six years in the automated controls industry and remaining years working
with the design, development and testing of radio communications and electronic equipment.

Positions Held

        Systems Engineer:      A/C Controls Mfg. Co., Inc. 6 Years

        Electrical Engineer:   Rogers Consulting Labs, Inc. 5 Years

        Electrical Engineer:   Rogers Labs, Inc. Current

Educational Background

1)      Bachelor of Science Degree in Electrical Engineering from Kansas State University.

2)      Bachelor of Science Degree in Business Administration Kansas State University.

3)      Several Specialized Training courses and seminars pertaining to Microprocessors and
        Software programming.



Scot D. Rogers




Rogers Labs, Inc.              Digital Monitoring Products, Inc.              SN: ENG1
4405 W. 259th Terrace          Models: 1127C Wireless PIR, 1127W Wireless PIR FCC ID#: CCKPC0152
Louisburg, KS 66053            Test #: 130415                                 IC: 5251A-PC0152
Phone/Fax: (913) 837-3214      Test to: CFR47 (15.249), RSS-210               Date: May 10, 2013
Revision 1                     File: DMP 1127CPIR TstRpt 130415               Page 25 of 27


                                                             FEDERAL COMMUNICATIONS COMMISSION
                                                                                                             Laboratory Division
                                                                                                        7435 Oakland Mills Road
                                                                                                             Columbia, MD21046

                                                                                                                   November O1, 2011

                                            |                                                                                                                                                                          Registration Number: 90910
    Rogers Labs, Inc.
    4405 West 259th Terrace,
    Louisburg, KS66053

    Attention:                                          Scot Rogers,

    Re:                                                 Measurement facilitylocated at Louisburg _
                                                        3 & 10 meter site
                                                        Date of Renewal: November 01, 201 1

    Dear Sir or Madam:

    Your request for renewal of the registration of the subject measurement facility has been received. The information
    submitted has been placed in your file and the registration has been renewed. The name of your organization will
    remain on the list of facilities whose measurement data will be accepted in conjunction with applications for
    Certification under Parts 15 or 18 of the Cormmssmns Rutes. Pleasenote that the file must be updated for any
    changes made to the facility and the teglstranmnmust be renewedat least every three years

    Measurement facilities that have indicated that they are avaliable to the public to performmeasurement services ona
    fee basis may be found on the FCC website www.fec.gov under E—Filing, OET Equipment Authorlz:atwn Electronic
    Filing, Test Firms.


                                                                                                                                                                                   Sincerely,



                                                                                                                                                                                   Phyillis Pérrish
                                                                                                                                                                                   Industry Analyst




a w es oyey e s     eceee ns w q          en w ie                              aacn en m s wen      k r w w aa ie w e e yey           e   e Ns   um er w e s q        n n w ie                                              ma   y e     azea   y   w




      wa_     ror     v     es o     sk         ns   w a i ue w e              alv s w wr w ns      e   ol ns e p    ow       ror   aaowe aw a2 k2    oal   acal us     aas ns m   r   on   ror   aawe e w w   ol   aslel   n   w wl      aale      ri   e       ow w ks      ow i2 i e e




a_gxs s® &k2 £2 NB L fay 40A mR                 xz xz xz as az                 uow kz w    broe     x 2 &z    ob   a ez                                                                                                     c wse      e adwes xob       m       m   N2\   a es is




s   aoa / aa wg   m       wa d me   y n   es j        zesd       &7 d ns   a   anowekz a   e rz e       No   i w     d    Y    aoar en     n n   gg    an wR Ks         ds nAz                                              zn sa c w e    alr w aa          y    xo ie    dz n is


NVLAP Lab Code 200087-0


Annex E Industry Canada Site Registration Letter




Rogers Labs, Inc.           Digital Monitoring Products, Inc.              SN: ENG1
4405 W. 259th Terrace       Models: 1127C Wireless PIR, 1127W Wireless PIR FCC ID#: CCKPC0152
Louisburg, KS 66053         Test #: 130415                                 IC: 5251A-PC0152
Phone/Fax: (913) 837-3214   Test to: CFR47 (15.249), RSS-210               Date: May 10, 2013
Revision 1                  File: DMP 1127CPIR TstRpt 130415               Page 27 of 27



Document Created: 2013-05-10 12:55:44
Document Modified: 2013-05-10 12:55:44

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC