Test Report

FCC ID: CCKPC0117

Test Report

Download: PDF
FCCID_1771460

NVLAP Lab Code 200087-0



        Class 2 Permissive Change
                               Test Report
                            For Certified Equipment

                                 MODEL: XTL
                             FCC ID: CCKPC0117
                              IC: 5251A-PC0117

                                              FOR


              Digital Monitoring Products, Inc.
                              2500 North Partnership Boulevard

                                Springfield, MO 65802-6310



                                Test Report Number: 120726




Rogers Labs, Inc.             Digital Monitoring Products, Inc.          SN: EUT1
4405 W. 259th Terrace         Model: XTLN-WIFI                           FCC ID#: CCKPC0117
Louisburg, KS 66053           Test #: 120726                             IC: 5251A-PC0117
Phone/Fax: (913) 837-3214     Test to: FCC 15C (15.249), IC RSS-210      Date: August 15, 2012
Revision 1                    File:DMP XTLN WIFI Class 2 Change 120726   Page 1 of 25


NVLAP Lab Code 200087-0

                            ROGERS LABS, INC.
                                         th
                            4405 West 259 Terrace
                            Louisburg, KS 66053
                            Phone / Fax (913) 837-3214



                       Class 2 Permissive Change
                                        Test Report
                                                    For


                    Digital Monitoring Products, Inc.
                                    2500 North Partnership Boulevard
                                      Springfield, MO 65802-6310

                                                Model: XTL

                                         Low Power Transmitter

                                              Frequency Range
                                              903 – 927.1 MHz

                                          FCC ID: CCKPC0117
                                           IC: 5251A-PC0117


Test Date: July 26, 2012


Certifying Engineer:
                        Scot D. Rogers
                        Rogers Labs, Inc.
                        4405 W. 259th Terrace
                        Louisburg, KS 66053
                        Telephone/Facsimile: (913) 837-3214


This report shall not be reproduced except in full, without the written approval of the laboratory.
This report must not be used by the client to claim product endorsement by NVLAP, NIST, or
any agency of the U.S. Government.


Rogers Labs, Inc.                 Digital Monitoring Products, Inc.          SN: EUT1
4405 W. 259th Terrace             Model: XTLN-WIFI                           FCC ID#: CCKPC0117
Louisburg, KS 66053               Test #: 120726                             IC: 5251A-PC0117
Phone/Fax: (913) 837-3214         Test to: FCC 15C (15.249), IC RSS-210      Date: August 15, 2012
Revision 1                        File:DMP XTLN WIFI Class 2 Change 120726   Page 2 of 25


NVLAP Lab Code 200087-0

Table Of Contents

TABLE OF CONTENTS.................................................................................................... 3

REVISIONS....................................................................................................................... 4

EXECUTIVE SUMMARY .................................................................................................. 5

FORWARD ....................................................................................................................... 5

OPINION / INTERPRETATION OF RESULTS ................................................................. 5

ENVIRONMENTAL CONDITIONS.................................................................................... 5

EQUIPMENT TESTED ...................................................................................................... 5

LIST OF TEST EQUIPMENT ............................................................................................ 6

TEST SITE LOCATIONS .................................................................................................. 7

EQUIPMENT CONFIGURATION ...................................................................................... 7

CHANGE TO EQUIPMENT .............................................................................................. 7

EMISSIONS TEST PROCEDURES .................................................................................. 8

   AC Line Conducted Emission Test Procedure ....................................................................................................... 8

   Radiated Emission Test Procedure ......................................................................................................................... 8

RESTRICTED BANDS OF OPERATION ......................................................................... 8

   General Radiated Emissions in Restricted Bands Data (worst-case) ................................................................... 9

   Summary of Results for Radiated Emissions in Restricted Bands ....................................................................... 9

AC LINE CONDUCTED EMISSIONS ............................................................................... 10

   AC Line Conducted Emissions Testing ................................................................................................................... 10

      Figure One AC Line Conducted emissions of EUT line 1 ..................................................................................... 11
      Figure Two AC Line Conducted emissions of EUT line 2 .................................................................................... 11

   Data, AC Line Conducted Emissions ...................................................................................................................... 12

   Summary of Results for AC Line Conducted Emissions ....................................................................................... 12

Rogers Labs, Inc.                              Digital Monitoring Products, Inc.                                        SN: EUT1
4405 W. 259th Terrace                          Model: XTLN-WIFI                                                         FCC ID#: CCKPC0117
Louisburg, KS 66053                            Test #: 120726                                                           IC: 5251A-PC0117
Phone/Fax: (913) 837-3214                      Test to: FCC 15C (15.249), IC RSS-210                                    Date: August 15, 2012
Revision 1                                     File:DMP XTLN WIFI Class 2 Change 120726                                 Page 3 of 25


NVLAP Lab Code 200087-0

RADIATED EMISSIONS TESTING PROCEDURE........................................................... 13

      Figure Three General Radiated Emissions taken at 1 meter in screen room .......................................................... 14
      Figure Four General Radiated Emissions taken at 1 meter in screen room ............................................................ 14
      Figure Five General Radiated Emissions taken at 1 meter in screen room ............................................................ 15
      Figure Six General Radiated Emissions taken at 1 meter in screen room .............................................................. 15

   Data, General Radiated Emissions .......................................................................................................................... 16

   Summary of Results for General Radiated Emissions ........................................................................................... 16

   Operation in the Band 902-928 MHz ...................................................................................................................... 17

   Data Transmitter Radiated Emissions .................................................................................................................... 18

   Summary of Results for Transmitter Radiated Emissions.................................................................................... 19

STATEMENT OF MODIFICATIONS AND DEVIATIONS ................................................. 19

ANNEX .............................................................................................................................. 20

   Annex A Measurement Uncertainty Calculations ................................................................................................. 21

   Annex B Rogers Labs Test Equipment List ........................................................................................................... 22

   Annex C Rogers Qualifications................................................................................................................................ 23

   Annex D FCC Test Site Registration Letter ........................................................................................................... 24

   Annex E Industry Canada Test Site Registration Letter ...................................................................................... 25

Revisions
Revision 1, Original Report Issued




Rogers Labs, Inc.                               Digital Monitoring Products, Inc.                                         SN: EUT1
4405 W. 259th Terrace                           Model: XTLN-WIFI                                                          FCC ID#: CCKPC0117
Louisburg, KS 66053                             Test #: 120726                                                            IC: 5251A-PC0117
Phone/Fax: (913) 837-3214                       Test to: FCC 15C (15.249), IC RSS-210                                     Date: August 15, 2012
Revision 1                                      File:DMP XTLN WIFI Class 2 Change 120726                                  Page 4 of 25


NVLAP Lab Code 200087-0

Executive Summary

In accordance with the Federal Communications Commission, Code of Federal Regulations CFR
47, dated October 1, 2011, Part 2, Subpart J, Paragraphs 2.907, 2.911, 2.913, 2.925, 2.926,
2.1041, 2.1043, applicable parts of paragraph 15, Part 15C paragraph 15.249, and RSS-210 the
following information is submitted in support of Class 2 permissive change of certified
equipment. Test procedures used are the established Methods of Measurement of Radio-Noise
Emissions as described in the ANSI 63.4-2009 Document.


Forward

The originally certified design was modified in accordance with permissible change requirements.
Additional circuitry was incorporated in the design offering ability for cabled network interfacing.


Opinion / Interpretation of Results

                        Test Performed                          Margin (dB)       Results
 Radiated Emissions in Restricted Bands                             -11.0        Complies

 AC Line Conducted Emissions                                        -11.5        Complies

 General Radiated Emissions                                          -7.5        Complies

 Transmitter Harmonic Emissions                                     -11.0        Complies


Environmental Conditions
        Ambient Temperature            24.2° C

        Relative Humidity              49%

        Atmospheric Pressure           1009.2 mb

Equipment Tested

Equipment               Model                  FCC ID                 Serial Number

EUT                     XTLN_WIFI              CCKPC0117              EUT1
AC Adapter              MGT-12500-SPS          N/A                    N/A

Rogers Labs, Inc.               Digital Monitoring Products, Inc.             SN: EUT1
4405 W. 259th Terrace           Model: XTLN-WIFI                              FCC ID#: CCKPC0117
Louisburg, KS 66053             Test #: 120726                                IC: 5251A-PC0117
Phone/Fax: (913) 837-3214       Test to: FCC 15C (15.249), IC RSS-210         Date: August 15, 2012
Revision 1                      File:DMP XTLN WIFI Class 2 Change 120726      Page 5 of 25


NVLAP Lab Code 200087-0

List of Test Equipment
A Rohde and Schwarz ESU40 and/or Hewlett Packard 8591EM Spectrum Analyzer was used as the
measuring device for the emissions testing of frequencies below 1 GHz. A Rohde and Schwarz
ESU40 and/or Hewlett Packard 8562A Spectrum Analyzer was used as the measuring device for
testing the emissions at frequencies above 1 GHz. The analyzer settings used are described in the
following table. Refer to the annex for a complete list of test equipment.


                                      Analyzer Settings
                               AC Line Conducted Emissions:
              RBW                         Video BW                    Detector Function
              9 kHz                         30 kHz                    Peak/Quasi Peak
                              Radiated Emissions 30-1000 MHz
              RBW                         Video BW                    Detector Function
            100 kHz                        100 kHz                           Peak
            120 kHz                        300 kHz                    Peak/Quasi Peak
                            Radiated Emissions Above 1000 MHz
              RBW                         Video BW                    Detector Function
             1 MHz                          1 MHz                      Peak / Average


Equipment       Manufacturer           Model                          Calibration Date       Due
LISN            Comp. Design           FCC-LISN-2-MOD.CD              10/11                  10/12
Antenna         ARA                    BCD-235-B                      10/11                  10/12
Antenna         EMCO                   3147                           10/11                  10/12
Antenna         EMCO                   3147                           10/11                  10/12
Antenna         Com Power              AH-118                         10/11                  10/12
Analyzer        HP                     8591EM                         5/12                   5/13
Analyzer        HP                     8562A                          5/12                   5/13
Analyzer        Rohde & Schwarz        ESU40                          5/12                   5/13




Rogers Labs, Inc.              Digital Monitoring Products, Inc.              SN: EUT1
4405 W. 259th Terrace          Model: XTLN-WIFI                               FCC ID#: CCKPC0117
Louisburg, KS 66053            Test #: 120726                                 IC: 5251A-PC0117
Phone/Fax: (913) 837-3214      Test to: FCC 15C (15.249), IC RSS-210          Date: August 15, 2012
Revision 1                     File:DMP XTLN WIFI Class 2 Change 120726       Page 6 of 25


NVLAP Lab Code 200087-0

Test Site Locations

Conducted EMI           The AC power line conducted emissions tests were performed in a
                        shielded screen room located at Rogers Labs, Inc., 4405 W. 259th Terrace,
                        Louisburg, KS.

Radiated EMI            The radiated emissions tests were performed at the 3 meters, Open Area
                        Test Site (OATS) located at Rogers Labs, Inc., 4405 W. 259th Terrace,
                        Louisburg, KS.

Site Registration       Refer to Annex for FCC Site registration Letter, Reference # 90910, and
                        Industry Canada registration IC3041A-1


Equipment Configuration


     XTLN-WIFI (EUT)                              AC /DC Power
                                                    Adapter

                            Power Cable


                                                   Utility Power



Change to Equipment

The change to the original design included addition of WiFi transceiver module FCC ID: XM5-
SM2144SMT. The circuitry change replaces original cellular module with WiFi module
supporting wireless communications with compliant WiFi network. Testing was performed to
verify the design continues to comply with all applicable rules and requirements of the Code of
Federal regulation 47 and Industry Canada. Testing confirmed the modifications do not degrade
the characteristics allowable and acceptable by the regulations. The transmitter is electrically
identical to the original design and application. The modification provided no change to the
certified operating power or frequency band. The WiFi transceiver module continued to function
in compliance with its authorization.
Rogers Labs, Inc.              Digital Monitoring Products, Inc.           SN: EUT1
4405 W. 259th Terrace          Model: XTLN-WIFI                            FCC ID#: CCKPC0117
Louisburg, KS 66053            Test #: 120726                              IC: 5251A-PC0117
Phone/Fax: (913) 837-3214      Test to: FCC 15C (15.249), IC RSS-210       Date: August 15, 2012
Revision 1                     File:DMP XTLN WIFI Class 2 Change 120726    Page 7 of 25


NVLAP Lab Code 200087-0

Emissions Test Procedures

AC Line Conducted Emission Test Procedure

Testing for the AC line-conducted emissions was performed as defined in sections 7.2.4 and 13
of ANSI C63.4-2009. The test setup, including the EUT, was arranged in the test configurations
as shown above and placed on a 1 x 1.5-meter wooden bench, 0.8 meters high located in a screen
room. The power lines of the system were isolated from the power source using a standard LISN
with a 50-µHy choke. EMI was coupled to the spectrum analyzer through a 0.1 µF capacitor
internal to the LISN. The LISN was positioned on the floor beneath the wooden bench
supporting the EUT. The power lines and cables were draped over the back edge of the table.
Refer to photographs in exhibits for EUT placement used during testing.

Radiated Emission Test Procedure

Testing of radiated emissions was performed as defined in section 8 of ANSI C63.4-2009. The
EUT was placed on a rotating 1 x 1.5-meter wooden platform, 0.8 meters above the ground plane
at a distance of 3 meters from the FSM antenna. EMI energy was maximized by equipment
placement, raising and lowering the FSM antenna, changing the antenna polarization, and by
rotating the turntable. Each emission was maximized before data was taken using a spectrum
analyzer. Refer to photographs in the exhibits for EUT placement.


Restricted Bands of Operation

Spurious emissions falling in the restricted frequency bands of operation were measured at a
distance of three meters at the OATS. The EUT utilizes frequency, determining circuitry, which
generates harmonics falling in the restricted bands. Emissions were investigated at the OATS,
using appropriate antennas or pyramidal horns, amplification stages, and spectrum analyzer.
Peak and average amplitudes of frequencies above 1000 MHz were compared to the required
limits with worst-case data presented below. Test procedures of ANSI 63.4-2003 paragraphs
13.1 and 8.3.1.2 were used during testing. No other significant emission was observed which fell
into the restricted bands of operation. Computed emission values take into account the received
radiated field strength, receive antenna correction factor, amplifier gain stage, and test system
cable losses.
Rogers Labs, Inc.              Digital Monitoring Products, Inc.             SN: EUT1
4405 W. 259th Terrace          Model: XTLN-WIFI                              FCC ID#: CCKPC0117
Louisburg, KS 66053            Test #: 120726                                IC: 5251A-PC0117
Phone/Fax: (913) 837-3214      Test to: FCC 15C (15.249), IC RSS-210         Date: August 15, 2012
Revision 1                     File:DMP XTLN WIFI Class 2 Change 120726      Page 8 of 25


NVLAP Lab Code 200087-0

Sample Calculation:
RFS (dBµV/m @ 3m) = FSM(dBµV) + A.F.(dB) - Gain(dB)

General Radiated Emissions in Restricted Bands Data (worst-case)

   Frequency in   Horizontal   Horizontal   Horizontal    Vertical    Vertical     Vertical   Limit @ 3m
      MHz           Peak       Quasi-Peak    Average       Peak      Quasi-Peak    Average
                  (dBµV/m)     (dBµV/m)     (dBµV/m)     (dBµV/m)    (dBµV/m)     (dBµV/m)     (dBµV/m)

     132.9          36.6         25.6         N/A         34.2         32.3        N/A           43.5
     134.0          32.8         17.7         N/A         34.8         14.3        N/A           43.5
     136.6          35.3         25.2         N/A         33.6         30.1        N/A           43.5
    2709.9          36.6         N/A          26.5        33.9         N/A         22.2          54.0
    2745.0          44.4         N/A          30.9        44.1         N/A         32.0          54.0
    2779.9          44.0         N/A          32.1        43.5         N/A         31.3          54.0
    3613.2          39.3         N/A          29.9        38.3         N/A         28.1          54.0
    3660.0          47.1         N/A          37.2        47.0         N/A         37.7          54.0
    3706.6          46.7         N/A          36.6        47.9         N/A         39.5          54.0
    4516.5          39.9         N/A          28.2        41.0         N/A         30.0          54.0
    4575.0          52.7         N/A          43.0        49.8         N/A         40.7          54.0
    4633.3          50.0         N/A          38.7        50.1         N/A         40.3          54.0
    5419.8          49.1         N/A          38.7        40.8         N/A         29.4          54.0
    5490.0          53.2         N/A          43.0        48.0         N/A         36.0          54.0
    5559.9          55.1         N/A          40.6        49.9         N/A         39.4          54.0
Other emissions present had amplitudes at least 20 dB below the limit. Peak and Quasi-Peak
amplitude emissions are recorded above for frequency range of 30-1000 MHz. Peak and
Average amplitude emissions are recorded above for frequency range above 1000 MHz.

Summary of Results for Radiated Emissions in Restricted Bands

The EUT demonstrated compliance with radiated emissions requirements of FCC Part 15C and
RSS-210 Intentional Radiators. The EUT presented with minimum margin of-11.0 dB below the
limit. Both average and peak amplitudes above 1000 MHz were investigated for compliance
with the regulations. No other emissions where found in the restricted frequency bands. Other
emissions were present with amplitudes at least 20 dB below the Limits.

Rogers Labs, Inc.                 Digital Monitoring Products, Inc.                 SN: EUT1
4405 W. 259th Terrace             Model: XTLN-WIFI                                  FCC ID#: CCKPC0117
Louisburg, KS 66053               Test #: 120726                                    IC: 5251A-PC0117
Phone/Fax: (913) 837-3214         Test to: FCC 15C (15.249), IC RSS-210             Date: August 15, 2012
Revision 1                        File:DMP XTLN WIFI Class 2 Change 120726          Page 9 of 25


NVLAP Lab Code 200087-0

AC Line Conducted Emissions

AC Line Conducted Emissions Testing

The EUT was arranged in typical equipment configurations (AC power adapter). Testing was
performed with the EUT placed on a 1 x 1.5-meter wooden bench 80 cm above the conducting
ground plane, floor of a screen room. The bench was positioned 40 cm away from the wall of
the screen room. The LISN was positioned on the floor of the screen room 80-cm from the rear
of the EUT. Testing for the line-conducted emissions were the procedures of ANSI C63.4-2009
paragraphs 13.1.3 and 7.2.4. The AC adapter for the EUT was connected to the LISN for line-
conducted emissions testing. A second LISN was positioned on the floor of the screen room 80-
cm from the rear of the supporting equipment of the EUT. All power cords except the EUT were
then powered from the second LISN. EMI was coupled to the spectrum analyzer through a 0.1
µF capacitor, internal to the LISN. Power line conducted emissions testing was carried out
individually for each current carrying conductor of the EUT. The excess length of lead between
the system and the LISN receptacle was folded back and forth to form a bundle not exceeding 40
cm in length. The screen room, conducting ground plane, analyzer, and LISN were bonded
together to the protective earth ground. Preliminary testing was performed to identify the
frequencies of each of the emissions, which had the highest amplitudes. The cables were
repositioned to obtain maximum amplitude of measured EMI level. Once the worst-case
configuration was identified, plots were made of the EMI from 0.15 MHz to 30 MHz then data
was recorded with maximum conducted emissions levels. Refer to Figures one and two showing
plots of the worst-case AC Line conducted emissions frequency spectrum taken in the screen
room.




Rogers Labs, Inc.             Digital Monitoring Products, Inc.            SN: EUT1
4405 W. 259th Terrace         Model: XTLN-WIFI                             FCC ID#: CCKPC0117
Louisburg, KS 66053           Test #: 120726                               IC: 5251A-PC0117
Phone/Fax: (913) 837-3214     Test to: FCC 15C (15.249), IC RSS-210        Date: August 15, 2012
Revision 1                    File:DMP XTLN WIFI Class 2 Change 120726     Page 10 of 25


NVLAP Lab Code 200087-0




Figure One AC Line Conducted emissions of EUT line 1




Figure Two AC Line Conducted emissions of EUT line 2


Rogers Labs, Inc.           Digital Monitoring Products, Inc.          SN: EUT1
4405 W. 259th Terrace       Model: XTLN-WIFI                           FCC ID#: CCKPC0117
Louisburg, KS 66053         Test #: 120726                             IC: 5251A-PC0117
Phone/Fax: (913) 837-3214   Test to: FCC 15C (15.249), IC RSS-210      Date: August 15, 2012
Revision 1                  File:DMP XTLN WIFI Class 2 Change 120726   Page 11 of 25


NVLAP Lab Code 200087-0

Data, AC Line Conducted Emissions

Line 1




Line 2




Other emissions present had amplitudes at least 20 dB below the limit.

Summary of Results for AC Line Conducted Emissions

The EUT demonstrated compliance with the conducted emissions requirements of CFR 47 Part
15C and other applicable standards for Intentional Radiators. The EUT worst-case configuration
demonstrated minimum margin of -11.5 dB below the CFR 47 limits. Other emissions were
present with recorded data representing the worst-case amplitudes.


Rogers Labs, Inc.            Digital Monitoring Products, Inc.           SN: EUT1
4405 W. 259th Terrace        Model: XTLN-WIFI                            FCC ID#: CCKPC0117
Louisburg, KS 66053          Test #: 120726                              IC: 5251A-PC0117
Phone/Fax: (913) 837-3214    Test to: FCC 15C (15.249), IC RSS-210       Date: August 15, 2012
Revision 1                   File:DMP XTLN WIFI Class 2 Change 120726    Page 12 of 25


NVLAP Lab Code 200087-0

Radiated Emissions Testing Procedure

The EUT was arranged in a typical equipment configuration and operated through all available
modes with worst-case data recorded. Preliminary testing was performed in a screen room with
the EUT positioned 1 meter from the FSM. Radiated emissions measurements were performed
to identify the frequencies, which produced the highest emissions. Plots were made of the
radiated frequency spectrum from 30 MHz to 25,000 MHz during the preliminary testing. Refer
to figures three through six for plots of the radiated emissions spectrum taken in a screen room.
The highest radiated emission was then re-maximized at the OATS location before final radiated
emissions measurements were performed. Final data was taken with the EUT located at the
OATS at a distance of 3 meters between the EUT and the receiving antenna. The frequency
spectrum from 30 MHz to 12,000 MHz was searched for radiated emissions. Measured emission
levels were maximized by EUT placement on the table, rotating the turntable through 360
degrees, varying the antenna height between 1 and 4 meters above the ground plane and
changing antenna position between horizontal and vertical polarization. Antennas used were
Broadband Biconical from 30 to 200 MHz, Biconilog from 30 to 1000 MHz, Log Periodic from
200 MHz to 1 GHz and or, pyramidal horns and mixers above 1 GHz notch filters and
appropriate amplifiers were utilized.




Rogers Labs, Inc.             Digital Monitoring Products, Inc.             SN: EUT1
4405 W. 259th Terrace         Model: XTLN-WIFI                              FCC ID#: CCKPC0117
Louisburg, KS 66053           Test #: 120726                                IC: 5251A-PC0117
Phone/Fax: (913) 837-3214     Test to: FCC 15C (15.249), IC RSS-210         Date: August 15, 2012
Revision 1                    File:DMP XTLN WIFI Class 2 Change 120726      Page 13 of 25


NVLAP Lab Code 200087-0




Figure Three General Radiated Emissions taken at 1 meter in screen room




Figure Four General Radiated Emissions taken at 1 meter in screen room


Rogers Labs, Inc.           Digital Monitoring Products, Inc.          SN: EUT1
4405 W. 259th Terrace       Model: XTLN-WIFI                           FCC ID#: CCKPC0117
Louisburg, KS 66053         Test #: 120726                             IC: 5251A-PC0117
Phone/Fax: (913) 837-3214   Test to: FCC 15C (15.249), IC RSS-210      Date: August 15, 2012
Revision 1                  File:DMP XTLN WIFI Class 2 Change 120726   Page 14 of 25


NVLAP Lab Code 200087-0




Figure Five General Radiated Emissions taken at 1 meter in screen room




Figure Six General Radiated Emissions taken at 1 meter in screen room


Rogers Labs, Inc.           Digital Monitoring Products, Inc.          SN: EUT1
4405 W. 259th Terrace       Model: XTLN-WIFI                           FCC ID#: CCKPC0117
Louisburg, KS 66053         Test #: 120726                             IC: 5251A-PC0117
Phone/Fax: (913) 837-3214   Test to: FCC 15C (15.249), IC RSS-210      Date: August 15, 2012
Revision 1                  File:DMP XTLN WIFI Class 2 Change 120726   Page 15 of 25


NVLAP Lab Code 200087-0


Data, General Radiated Emissions

   Frequency in   Horizontal   Horizontal   Horizontal    Vertical    Vertical     Vertical    Limit @ 3m
      MHz           Peak       Quasi-Peak    Average       Peak      Quasi-Peak    Average
                  (dBµV/m)     (dBµV/m)     (dBµV/m)     (dBµV/m)    (dBµV/m)     (dBµV/m)      (dBµV/m)

      52.3          39.5         23.2         N/A         40.6         32.5        N/A            40.0

      53.8          41.1         25.8         N/A         37.9         31.1        N/A            40.0

     132.9          36.6         25.6         N/A         34.2         32.3        N/A            43.5

     134.0          32.8         17.7         N/A         34.8         14.3        N/A            43.5

     136.6          35.3         25.2         N/A         33.6         30.1        N/A            43.5

     167.5          36.7         23.1         N/A         29.1         26.6        N/A            43.5

     182.8          33.2         26.5         N/A         33.0         29.9        N/A            43.5

     183.6          36.6         23.4         N/A         32.5         29.9        N/A            43.5

     184.4          38.3         23.4         N/A         32.0         29.5        N/A            43.5

     186.7          29.4         23.5         N/A         32.2         28.9        N/A            43.5

     902.0          51.5         36.8         N/A         49.7         29.8        N/A            46.0

     928.0          50.5         32.2         N/A         49.0         29.6        N/A            46.0
Other emissions present had amplitudes at least 20 dB below the limit. Peak and Quasi-Peak
amplitude emissions are recorded above for frequency range of 30-1000 MHz. Peak and
Average amplitude emissions are recorded above for frequency range above 1000 MHz.

Summary of Results for General Radiated Emissions

The EUT demonstrated compliance with radiated emissions requirements for CFR 47 Part 15C,
and Industry Canada requirements. The EUT presented with -7.5 dB minimum margin below the
limit. Other emissions were present with amplitudes at least 20 dB below the limit.




Rogers Labs, Inc.                 Digital Monitoring Products, Inc.                  SN: EUT1
4405 W. 259th Terrace             Model: XTLN-WIFI                                   FCC ID#: CCKPC0117
Louisburg, KS 66053               Test #: 120726                                     IC: 5251A-PC0117
Phone/Fax: (913) 837-3214         Test to: FCC 15C (15.249), IC RSS-210              Date: August 15, 2012
Revision 1                        File:DMP XTLN WIFI Class 2 Change 120726           Page 16 of 25


NVLAP Lab Code 200087-0

Operation in the Band 902-928 MHz

The power output was measured on an open area test site @ 3 meters. Test procedures of ANSI
63.4-2003 paragraphs 13.1 and 8.3.1.2 were used during testing. The EUT was placed on a wooden
turntable 0.8 meters above the ground plane and at a distance of 3 meters from the FSM antenna.
The peak and quasi-peak amplitude of frequencies below 1000 MHz were measured using a
spectrum analyzer. The peak and average amplitude of frequencies above 1000 MHZ were
measured using a spectrum analyzer. The amplitude of the emission was then recorded from the
analyzer display. Emissions radiated outside of the specified bands, except for harmonics, shall be
attenuated by at least 50 dB below the level of the fundamental or to the general radiated emission
limits in 15.209, whichever is the lesser attenuation. The amplitudes of each radiated spurious
emission were measured at the OATS at a distance of 3 meters from the FSM antenna. The
amplitude of each radiated spurious emission was maximized by varying the FSM antenna height,
polarization, and by rotating the turntable. A Biconilog Antenna was used for measuring emissions
from 30 to 1000 MHz, a Log Periodic Antenna for 200 to 1000 MHz, and Double-ridge horn and/or
Pyramidal Horn Antennas from 1 GHz to 25 GHz. Emissions were measured in dBµV/m @ 3
meters.




Rogers Labs, Inc.             Digital Monitoring Products, Inc.            SN: EUT1
4405 W. 259th Terrace         Model: XTLN-WIFI                             FCC ID#: CCKPC0117
Louisburg, KS 66053           Test #: 120726                               IC: 5251A-PC0117
Phone/Fax: (913) 837-3214     Test to: FCC 15C (15.249), IC RSS-210        Date: August 15, 2012
Revision 1                    File:DMP XTLN WIFI Class 2 Change 120726     Page 17 of 25


NVLAP Lab Code 200087-0

Data Transmitter Radiated Emissions

   Frequency in   Horizontal   Horizontal   Horizontal    Vertical    Vertical     Vertical    Limit @ 3m
      MHz           Peak       Quasi-Peak    Average       Peak      Quasi-Peak    Average
                  (dBµV/m)     (dBµV/m)     (dBµV/m)     (dBµV/m)    (dBµV/m)     (dBµV/m)      (dBµV/m)

     905.6          93.3         N/A          93.0        93.2         N/A         92.5           94.0

    1806.7          40.1         N/A          35.4        43.8         N/A         40.1           54.0

    2709.9          36.6         N/A          26.5        33.9         N/A         22.2           54.0

    3613.2          39.3         N/A          29.9        38.3         N/A         28.1           54.0

    4516.5          39.9         N/A          28.2        41.0         N/A         30.0           54.0

    5419.8          49.1         N/A          38.7        40.8         N/A         29.4           54.0

     915.0          92.8         N/A          92.7        92.7         N/A         92.6           94.0

    1830.0          40.0         N/A          28.1        40.4         N/A         30.9           54.0

    2745.0          44.4         N/A          30.9        44.1         N/A         32.0           54.0

    3660.0          47.1         N/A          37.2        47.0         N/A         37.7           54.0

    4575.0          52.7         N/A          43.0        49.8         N/A         40.7           54.0

    5490.0          53.2         N/A          43.0        48.0         N/A         36.0           54.0

     924.0          92.5         N/A          92.2        90.6         N/A         90.4           94.0

    1853.3          42.3         N/A          33.5        42.4         N/A         34.7           54.0

    2779.9          44.0         N/A          32.1        43.5         N/A         31.3           54.0

    3706.6          46.7         N/A          36.6        47.9         N/A         39.5           54.0

    4633.3          50.0         N/A          38.7        50.1         N/A         40.3           54.0

    5559.9          55.1         N/A          40.6        49.9         N/A         39.4           54.0
Other emissions present had amplitudes at least 20 dB below the limit. Peak and Quasi-Peak
amplitude emissions are recorded above for frequency range of 30-1000 MHz. Peak and
Average amplitude emissions are recorded above for frequency range above 1000 MHz.




Rogers Labs, Inc.                 Digital Monitoring Products, Inc.                  SN: EUT1
4405 W. 259th Terrace             Model: XTLN-WIFI                                   FCC ID#: CCKPC0117
Louisburg, KS 66053               Test #: 120726                                     IC: 5251A-PC0117
Phone/Fax: (913) 837-3214         Test to: FCC 15C (15.249), IC RSS-210              Date: August 15, 2012
Revision 1                        File:DMP XTLN WIFI Class 2 Change 120726           Page 18 of 25


NVLAP Lab Code 200087-0

Summary of Results for Transmitter Radiated Emissions

The EUT demonstrated compliance with the radiated emissions requirements of CFR 47 Part
15.249, RSS-210 and other applicable standards for Intentional Radiators. The EUT
demonstrated compliance for the transmitter fundamental with a margin of -1.0 dB below the
limit. The EUT worst-case configuration demonstrated minimum radiated harmonic emission
margin of -11.0 dB below the limits. No other radiated emissions were found in the restricted
bands less than 20 dB below limits than those recorded in this report. Other emissions were
present with amplitudes at least 20 dB below the Limits.

Note: Some measurements taken during this investigation presented results having margins
below the laboratory calculated measurement uncertainty values.


Statement of Modifications and Deviations

No modifications to the EUT were required for the unit to demonstrate compliance with the
CFR47 Part 15C or RSS-210 requirements. There were no deviations or exceptions to the
specifications.




Rogers Labs, Inc.            Digital Monitoring Products, Inc.            SN: EUT1
4405 W. 259th Terrace        Model: XTLN-WIFI                             FCC ID#: CCKPC0117
Louisburg, KS 66053          Test #: 120726                               IC: 5251A-PC0117
Phone/Fax: (913) 837-3214    Test to: FCC 15C (15.249), IC RSS-210        Date: August 15, 2012
Revision 1                   File:DMP XTLN WIFI Class 2 Change 120726     Page 19 of 25


NVLAP Lab Code 200087-0

Annex



   Annex A Measurement Uncertainty Calculations

   Annex B Rogers Labs Test Equipment List

   Annex C Rogers Qualifications

   Annex D FCC Site Registration Letter

   Annex E Industry Canada Site Registration Letter

   Annex F Photographs of Test Setup

   Annex G Photographs of Equipment Under Test




Rogers Labs, Inc.            Digital Monitoring Products, Inc.          SN: EUT1
4405 W. 259th Terrace        Model: XTLN-WIFI                           FCC ID#: CCKPC0117
Louisburg, KS 66053          Test #: 120726                             IC: 5251A-PC0117
Phone/Fax: (913) 837-3214    Test to: FCC 15C (15.249), IC RSS-210      Date: August 15, 2012
Revision 1                   File:DMP XTLN WIFI Class 2 Change 120726   Page 20 of 25


NVLAP Lab Code 200087-0

Annex A Measurement Uncertainty Calculations

Measurement uncertainty calculations were made for the laboratory. Result of measurement
uncertainty calculations are recorded below for AC line conducted and radiated emission
measurements.


Measurement Uncertainty                                         U(E)              U(lab)

3 Meter Horizontal 30-200 MHz Measurements                      2.08               4.16

3 Meter Vertical 30-200 MHz Measurements                        2.16               4.33

3 Meter Vertical Measurements 200-1000 MHz                      2.99               5.97

10 Meter Horizontal Measurements 30-200 MHz                     2.07               4.15

10 Meter Vertical Measurements 30-200 MHz                       2.06               4.13

10 Meter Horizontal Measurements 200-1000 MHz                   2.32               4.64

10 Meter Vertical Measurements 200-1000 MHz                     2.33               4.66

3 Meter Measurements 1-6 GHz                                    2.57               5.14

3 Meter Measurements 6-18 GHz                                   2.58               5.16

AC Line Conducted                                               1.72               3.43




Rogers Labs, Inc.            Digital Monitoring Products, Inc.           SN: EUT1
4405 W. 259th Terrace        Model: XTLN-WIFI                            FCC ID#: CCKPC0117
Louisburg, KS 66053          Test #: 120726                              IC: 5251A-PC0117
Phone/Fax: (913) 837-3214    Test to: FCC 15C (15.249), IC RSS-210       Date: August 15, 2012
Revision 1                   File:DMP XTLN WIFI Class 2 Change 120726    Page 21 of 25


NVLAP Lab Code 200087-0

Annex B Rogers Labs Test Equipment List
The test equipment is maintained in calibration and good operating condition. Use of this
calibrated equipment ensures measurements are traceable to national standards.
List of Test Equipment                                                    Calibration Date
Spectrum Analyzer: Rohde & Schwarz ESU40                                         5/12
Spectrum Analyzer: HP 8562A, HP Adapters: 11518, 11519, and 11520                5/12
        Mixers: 11517A, 11970A, 11970K, 11970U, 11970V, 11970W
Spectrum Analyzer: HP 8591EM                                                     5/12
Antenna: EMCO Biconilog Model: 3143                                              5/12
Antenna: Sunol Biconilog Model: JB6                                              10/11
Antenna: EMCO Log Periodic Model: 3147                                           10/11
Antenna: Antenna Research Biconical Model: BCD 235                               10/11
LISN: Compliance Design Model: FCC-LISN-2.Mod.cd, 50 μHy/50 ohm/0.1 µf 10/11
R.F. Preamp CPPA-102                                                             10/11
Attenuator: HP Model: HP11509A                                                   10/11
Attenuator: Mini Circuits Model: CAT-3                                           10/11
Attenuator: Mini Circuits Model: CAT-3                                           10/11
Cable: Belden RG-58 (L1)                                                         10/11
Cable: Belden RG-58 (L2)                                                         10/11
Cable: Belden 8268 (L3)                                                          10/11
Cable: Time Microwave: 4M-750HF290-750                                           10/11
Cable: Time Microwave: 10M-750HF290-750                                          10/11
Frequency Counter: Leader LDC825                                                 2/12
Oscilloscope Scope: Tektronix 2230                                               2/12
Wattmeter: Bird 43 with Load Bird 8085                                           2/12
Power Supplies: Sorensen SRL 20-25, SRL 40-25, DCR 150, DCR 140                  2/12
R.F. Generators: HP 606A, HP 8614A, HP 8640B                                     2/12
 R.F. Power Amp 65W Model: 470-A-1010                                            2/12
R.F. Power Amp 50W M185- 10-501                                                  2/12
R.F. Power Amp A.R. Model: 10W 1010M7                                            2/12
R.F. Power Amp EIN Model: A301                                                   2/12
LISN: Compliance Eng. Model 240/20                                               2/12
LISN: Fischer Custom Communications Model: FCC-LISN-50-16-2-08                   2/12
Antenna: EMCO Dipole Set 3121C                                                   2/12
Antenna: C.D. B-101                                                              2/12
Antenna: Solar 9229-1 & 9230-1                                                   2/12
Antenna: EMCO 6509                                                               2/12
Audio Oscillator: H.P. 201CD                                                     2/12
Peavey Power Amp Model: IPS 801                                                  2/12
ELGAR Model: 1751                                                                2/12
ELGAR Model: TG 704A-3D                                                          2/12
ESD Test Set 2010i                                                               2/12
Fast Transient Burst Generator Model: EFT/B-101                                  2/12
Field Intensity Meter: EFM-018                                                   2/12
KEYTEK Ecat Surge Generator                                                      2/12
Shielded Room 5 M x 3 M x 3.0 M
Rogers Labs, Inc.            Digital Monitoring Products, Inc.           SN: EUT1
4405 W. 259th Terrace        Model: XTLN-WIFI                            FCC ID#: CCKPC0117
Louisburg, KS 66053          Test #: 120726                              IC: 5251A-PC0117
Phone/Fax: (913) 837-3214    Test to: FCC 15C (15.249), IC RSS-210       Date: August 15, 2012
Revision 1                   File:DMP XTLN WIFI Class 2 Change 120726    Page 22 of 25


NVLAP Lab Code 200087-0


Annex C Rogers Qualifications

Scot D. Rogers, Engineer

Rogers Labs, Inc.

Mr. Rogers has approximately 17 years’ experience in the field of electronics. Work experience
includes six years working in the automated controls industry and remaining years working with
the design, development and testing of radio communications and electronic equipment.

Positions Held:

        Systems Engineer:      A/C Controls Mfg. Co., Inc. 6 Years

        Electrical Engineer:   Rogers Consulting Labs, Inc. 5 Years

        Electrical Engineer:   Rogers Labs, Inc. Current

Educational Background:

1)      Bachelor of Science Degree in Electrical Engineering from Kansas State University

2)      Bachelor of Science Degree in Business Administration Kansas State University

3)      Several Specialized Training courses and seminars pertaining to Microprocessors and
        Software programming.




Rogers Labs, Inc.              Digital Monitoring Products, Inc.          SN: EUT1
4405 W. 259th Terrace          Model: XTLN-WIFI                           FCC ID#: CCKPC0117
Louisburg, KS 66053            Test #: 120726                             IC: 5251A-PC0117
Phone/Fax: (913) 837-3214      Test to: FCC 15C (15.249), IC RSS-210      Date: August 15, 2012
Revision 1                     File:DMP XTLN WIFI Class 2 Change 120726   Page 23 of 25


                     FEDERAL COMMUNICATIONS COMMISSION
                                               Laboratory Division
                                            7435 Oakland Mills Road
                                              Columbia, MD21046
                                                November 01. 2011

              |                                                                           Registration Number: 90910
Rogers Labs, Inc.
4405 West 259th Terrace,
Louisburg, KS 66053

Attention:        Scot Rogers,

Re:               Measurement facility located at Louisburg _
                  3 & 10 meter site
                  Date of Renewal: November 01, 2011

Dear Sir or Madam:

Your request for renewal of the registration of the subject measurement facility has been received. The information
submitted has been placed in your file and the registration has been renewed. The name of your organization will
remain on the list of facilities whose measurement data will be accepted in conjpunction with applications for
Certification under Parts 15 or 18 of the Commmsmns Rules. Pleasenote that the file must be updated for any
changes made to the facility and the r&glsiratmnmust be renewedat least every three years

  Measurement facilities that have indicated that they are avafiab}e to the public to performmeasurement services ona
  fee basis may be found on the FCC website www.fec.gov under E—Filing, OET Equipment Authonzatwn Electronic
_ Fflmg, Test Firms.



                                                                        Sincerely,


                                                                        Phyilis Pérrish
                                                                        Industry Analyst


  HD ingusty ingustre

‘December 28, 2011                _             Wls              _ OUR FILE: 46405—3041 _
                                  O             o                    _ Submission No: 152685

 Rogers Labs Inc.
 4405 West 259th Terrance
 Louisburg, KS, 66053
 USA



 Attention: Mr. Scot D. Rogers

 DearSir/Madame:
 The Bureau has received your application for the renewal of 3/10m OATS. Be advised that the information
 received was satisfactory to Industry Canada. The following number(s) is now associated to the site(s) for
 which registration / renewal was sought ( Site# 3041A—1 ). Please reference the appropriate site number in
 the body of test reports containing measurements performed on the site. Inaddltlon please keep for your
 records the followmg information;                                   -         :

 — The company address code associated to the sne(s) located at the above addressis: 3041A

 Fm'thennore to obtain or renew a unique site number, the apphcant shall demonstrate that the site has been
 accredited to ANSI C63.4—2003 or later. A scope of accreditationindicating the accreditation by a recognized
 accreditation body to ANSI C63.4—2003 or later shall be accepted. Please indicate in a letter the previous
 assigned site number if applicable and the type of site (example: 3 metre OATS or 3 metre chamber). Ifthe test
 facility is not accredited to ANSI C63.4—2003 or later, the test facility shall submit test data demonstrating full
 compliancewith the ANSI standard. The Bureau will evaluate the filing to determine if recognltmn shall be
 granted

The frequency for re—validation ofthe test site and the information that is required to be filed or retained bythe |
 testing party shall comply withthe requirements established by the accrediting organization. However, in all _
 cases, test site re—validation shall occur on an interval not to exceed three years. There is no fee or form
 associated with an OATS filing. OATS submlsswns are encouraged to be submitted electronically to the
 Bureau using the following URL;
 http://strategis.ic.go.ca/epic/internet/inceb—bhstnsf/en/h:t100052e.html.

 If you have any questions, you may contact the Bureau by e—mail at certlficatlonbureau@ic.ge.ca Please
 reference our file and submission number above for all correspundence                          |

 Yours sincerely,




_ Dalwinder Gill                      |
 For: Wireless Laboratory Manager _ _
 Certification and Engineering Bureau
 3701 Carling Ave., Building 94  —_ _
 P.O. Box 11490, Station "H" _ _
 Ottawa, Ontario K2H 852
 Email: dalwinder.gill@ic. ge.ca
 Tel. No. (613) 998—8363 _ _
 Fax. No. (613) 990—4752



Document Created: 2012-08-15 10:16:28
Document Modified: 2012-08-15 10:16:28