12122303-E3V2 FCCIC MPE Report

FCC ID: C9O-SLMB1

RF Exposure Info

Download: PDF
FCCID_4066120

                FCC Part 1 Subpart I
               FCC Part 2 Subpart J
         INDUSTRY CANADA RSS 102 ISSUE 5

                   MPE REPORT

                        FOR

ELECTRONIC CONTROLLER WITH AIREA AND BLE RADIOS

              MODEL NUMBER: 00220

                FCC ID: C9O-SLMB1
                 IC: 1016A-SLMB1

          REPORT NUMBER: 12122303-E3V2

            ISSUE DATE: October 24, 2018


                    Prepared for
                    SRAM LLC
         1000 W FULTON MARKET 4TH FLOOR
              CHICAGO, IL 60607 U.S.A


                    Prepared by
          UL VERIFICATION SERVICES INC.
              47173 BENICIA STREET
            FREMONT, CA 94538, U.S.A.
                TEL: (510) 771-1000
                FAX: (510) 661-0888




               NVLAP LAB CODE 200065-0


REPORT NO:12122303-E3V2                                                                             DATE: 10/24/2018
FCC ID: C9O-SLMB1                                                                                   IC: 1016A-SLMB1

                                                  Revision History

            Issue
 Rev.       Date               Revisions                                                                Revised By
  V1        10/5/2018          Initial Issue
  V2        10/24/2018         Updated Power and Tolerances                                             Steven Tran




                                      Page 2 of 6
UL VERIFICATION SERVICES INC.                                         FORM NO: CCSUP4701I
47173 BENICIA STREET, FREMONT, CA 94538, USA      TEL: (510) 771-1000    FAX: (510) 661-0888
   This report shall not be reproduced except in full, without the written approval of . UL Verification Services Inc.


REPORT NO:12122303-E3V2                                                                                                DATE: 10/24/2018
FCC ID: C9O-SLMB1                                                                                                      IC: 1016A-SLMB1

                                                TABLE OF CONTENTS
1.     ATTESTATION OF TEST RESULTS ................................................................................. 4

2.     TEST METHODOLOGY ..................................................................................................... 5

3.     REFERENCES ................................................................................................................... 5

4.     FACILITIES AND ACCREDITATION ................................................................................. 5

5.     DEVICE UNDER TEST ....................................................................................................... 5

6.     MAXIMUM OUTPUT POWER ............................................................................................ 5

7.     STANDALONE SAR TEST EXCLUSION CONSIDERATIONS .......................................... 6
     7.1.    FCC ............................................................................................................................. 6




                                      Page 3 of 6
UL VERIFICATION SERVICES INC.                                         FORM NO: CCSUP4701I
47173 BENICIA STREET, FREMONT, CA 94538, USA      TEL: (510) 771-1000    FAX: (510) 661-0888
     This report shall not be reproduced except in full, without the written approval of . UL Verification Services Inc.


REPORT NO:12122303-E3V2                                                                             DATE: 10/24/2018
FCC ID: C9O-SLMB1                                                                                   IC: 1016A-SLMB1


1. ATTESTATION OF TEST RESULTS
COMPANY NAME:                       SRAM LLC
                                    1000 W Fulton Market 4th Floor
                                    Chicago, IL 60607 U.S.A

EUT DESCRIPTION:                    Electronic Controller with AIREA and BLE radios

MODEL:                              00220


                                          APPLICABLE STANDARDS
                               STANDARD                                                 TEST RESULTS
          FCC PART 1 SUBPART I & PART 2 SUBPART J                                            Complies
                        ISED RSS 102 ISSUE 5                                                 Complies


 UL Verification Services Inc. calculated the RF Exposure of the above equipment in
accordance with the requirements set forth in the above standards, using test results reported in
the test report documents referenced below and/or documentation furnished by the applicant.
All indications of Pass/Fail in this report are opinions expressed by UL Verification Services Inc.
based on interpretations of these calculations. The results show that the equipment is capable
of demonstrating compliance with the requirements as documented in this report.

Note: The results documented in this report apply only to the tested sample, under the
conditions and modes of operation as described herein. This document may not be altered or
revised in any way unless done so by UL Verification Services Inc. and all revisions are duly
noted in the revisions section. Any alteration of this document not carried out by UL Verification
Services Inc. will constitute fraud and shall nullify the document. This report must not be used
by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any
agency of the U.S. Government.

Approved & Released For
UL Verification Services Inc. By:                                Reviewed By:




DAN CORONIA                                                      STEVEN TRAN
CONSUMER TECHNOLOGY DIVISION                                     CONSUMER TECHNOLOGY DIVISION
OPERATIONS LEADER                                                PROJECT ENGINEER
UL Verification Services Inc.                                    UL Verification Services Inc




                                      Page 4 of 6
UL VERIFICATION SERVICES INC.                                         FORM NO: CCSUP4701I
47173 BENICIA STREET, FREMONT, CA 94538, USA      TEL: (510) 771-1000    FAX: (510) 661-0888
   This report shall not be reproduced except in full, without the written approval of . UL Verification Services Inc.


REPORT NO:12122303-E3V2                                                                             DATE: 10/24/2018
FCC ID: C9O-SLMB1                                                                                   IC: 1016A-SLMB1


2. TEST METHODOLOGY
All calculations were made in accordance with FCC OET Bulletin 65 Edition 97-01 and ISED
Safety Code 6.


3. REFERENCES
All measurements were made as documented in test report UL Verification Services Inc.
Document 12122303-E1 and 12122303-E2 for operation in the 2.4 GHz band and UL
Verification Services Inc.

Output power, Duty cycle and Antenna gain data is excerpted from the applicable test reports.



4. FACILITIES AND ACCREDITATION
The test sites and measurement facilities used to collect data are located at 47173 and 47266
Benicia Street, Fremont, California, USA.

UL Verification Services Inc. is accredited by NVLAP, Laboratory Code 200065-0. The full
scope of accreditation can be viewed at http://ts.nist.gov/standards/scopes/2000650.htm.


5. DEVICE UNDER TEST
The EUT is an Electronic Controller with radios BLE operating in the frequency range of 2402 to
2480 MHz and AIREA operating in the frequency range of 2405 to 2480. The user to antenna
separation distance is 0mm.


6. MAXIMUM OUTPUT POWER
The maximum output power of the device is declared as the following:

BLE = 0dBm ±3dB; Antenna Gain: 1.3 dBi
AIREA = 0dBm ±2dB; Antenna Gain: 1.3 dBi




                                      Page 5 of 6
UL VERIFICATION SERVICES INC.                                         FORM NO: CCSUP4701I
47173 BENICIA STREET, FREMONT, CA 94538, USA      TEL: (510) 771-1000    FAX: (510) 661-0888
   This report shall not be reproduced except in full, without the written approval of . UL Verification Services Inc.


REPORT NO:12122303-E3V2                                                                                DATE: 10/24/2018
FCC ID: C9O-SLMB1                                                                                      IC: 1016A-SLMB1

7. STANDALONE SAR TEST EXCLUSION CONSIDERATIONS
    7.1.           FCC
SAR test exclusion in accordance with KDB 447498 D01 v06.

The 1-g and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation distances
≤ 50 mm are determined by:
[(max. power of channel, including tune-up tolerance, mW) / (min. test separation distance, mm)]·[√f(GHz)] ≤ 3.0, for
1-g SAR and ≤ 7.5 for 10-g extremity SAR, where
    •     f(GHz) is the RF channel transmit frequency in GHz
    •     Power and distance are rounded to the nearest mW and mm before calculation
    •     The result is rounded to one decimal place for comparison
This test exclusion is applicable only when the minimum test separation distance is ≤ 50 mm and for
transmission frequencies between 100 MHz and 6 GHz. When the minimum test separation distance is <
5 mm, a distance of 5 mm is applied to determine SAR test exclusion.

SAR Exclusion Calculation Table for Portable Devices (Separation distance < 50mm)
             Frequency     Max Output power                          Max Output Power                Separation       Calculated
    Tx                                          Duty Cycle
               (MHz)       dBm        mW                       with Duty factor correction (mW)   distances (mm)   Threshold Value

   BLE         2480         3.0         2         100%                        2                         5                0.6



             Frequency     Max Output power                          Max Output Power                Separation       Calculated
    Tx                                          Duty Cycle
               (MHz)       dBm        mW                       with Duty factor correction (mW)   distances (mm)   Threshold Value

  AIREA        2480         2.0         2         100%                        2                         5                0.6


Conclusion:
The device operates with a maximum Duty Cycle of 100%. The Calculated Threshold with duty cycle
applied is ≤3 for 1-g SAR and ≤7 for 10-g extremity SAR; therefore, this device qualifies for Standalone
SAR test exclusion.

                                              END OF REPORT




                                      Page 6 of 6
UL VERIFICATION SERVICES INC.                                         FORM NO: CCSUP4701I
47173 BENICIA STREET, FREMONT, CA 94538, USA      TEL: (510) 771-1000    FAX: (510) 661-0888
   This report shall not be reproduced except in full, without the written approval of . UL Verification Services Inc.



Document Created: 2019-04-06 02:26:33
Document Modified: 2019-04-06 02:26:33

© 2025 FCC.report
This site is not affiliated with or endorsed by the FCC