                                                     RF Exposure Test Report

                       Report No.: SA190716C36

                             FCC ID: C3K1915

                       Test Model: 1915

                 Received Date: Jul. 3, 2019

                         Test Date: Jul. 9, 2019

                     Issued Date: Jul. 22, 2019


                         Applicant: MICROSOFT CORPORATION

                          Address: ONE MICROSOFT WAY REDMOND, WA 98052-6399


                        Issued By: Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch

                    Lab Address: No. 47-2, 14th Ling, Chia Pau Vil., Lin Kou Dist., New Taipei City, Taiwan,
                                 R.O.C.
         FCC Registration /
       Designation Number: 198487 / TW2021




This report is for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted
only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this
report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product
unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you
provided to us. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence, provided,
however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time
shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Unless specific
mention, the uncertainty of measurement has been explicitly taken into account to declare the compliance or non-compliance to the specification.
The report must not be used by the client to claim product certification, approval, or endorsement by TAF or any government agencies.
Report No.: SA190716C36                                              Page No. 1 / 11                                            Report Format Version: 6.1.1


                                                                   Table of Contents
Release Control Record .................................................................................................................................. 3
1         Certificate of Conformity...................................................................................................................... 4
2         General Information .............................................................................................................................. 5
    2.1      General Description of EUT ................................................................................................................ 5
3         RF Exposure .......................................................................................................................................... 6
    3.1      Description of Support Units ............................................................................................................... 6
    3.1.1    Configuration of System under Test .................................................................................................... 6
    3.2      Test Setup ........................................................................................................................................... 7
    3.3      Test Instruments .................................................................................................................................. 7
    3.4      Limits for Maximum Permissible Exposure (MPE) .............................................................................. 8
    3.5      Test Point Description ......................................................................................................................... 8
4         Calculation Result of Maximum Conducted Power........................................................................... 9
5         Photographs of the Test Configuration ............................................................................................. 11




Report No.: SA190716C36                                              Page No. 2 / 11                                             Report Format Version: 6.1.1


                                          Release Control Record


Issue No.             Description                                         Date Issued
SA190716C36           Original release.                                   Jul. 22, 2019




Report No.: SA190716C36                      Page No. 3 / 11       Report Format Version: 6.1.1


1    Certificate of Conformity


            Product: Wireless charger

              Brand: Microsoft

        Test Model: 1915

    Sample Status: Engineering sample

          Applicant: MICROSOFT CORPORATION

          Test Date: Jul. 9, 2019

         Standards: FCC Part 2 (Section 2.1091)
                          FCC Part 1 (Section 1.1307(c) and (d), Section 1.1310)
                          KDB 680106 D01 RF Exposure Wireless Charging v03



The above equipment has been tested by Bureau Veritas Consumer Products Services (H.K.) Ltd.,
Taoyuan Branch, and found compliance with the requirement of the above standards. The test record, data
evaluation & Equipment Under Test (EUT) configurations represented herein are true and accurate accounts
of the measurements of the sample’s RF characteristics under the conditions specified in this report.




     Prepared by :                                                      , Date:          Jul. 22, 2019
                               Jessica Cheng / Senior Specialist




     Approved by :                                                      , Date:          Jul. 22, 2019
                            Rex Lai / Associate Technical Manager




Report No.: SA190716C36                         Page No. 4 / 11                       Report Format Version: 6.1.1


2     General Information
2.1    General Description of EUT

 Product                              Wireless charger
 Brand                                Microsoft
 Test Model                           1915
 Sample Status                        Engineering sample
 Rating                               5Vdc , 200mA
 Modulation Type                      ASK
 Operating Frequency                  13.56MHz
 Antenna Type                         NFC FPC loop antenna
 Field Strength                       37.69dBuV/m
 Dimensions                           162.9mm*17mm *9.9 mm
 Accessory Device                     N/A
 Data Cable Supplied                  USB to type C shielded cable (0.45m)
 Maximum Power Output from the
                                      300mW
 Charging Coil
Note: The above EUT information is declared by manufacturer and for more detailed features description,
please refer to the manufacturer's specifications or user's manual.




Report No.: SA190716C36                      Page No. 5 / 11                       Report Format Version: 6.1.1


3        RF Exposure
3.1       Description of Support Units
The EUT has been tested as an independent unit together with other necessary accessories or support units.
The following support units or accessories were used to form a representative test configuration during the
tests.
    ID        Product            Brand            Model No.             Serial No.             FCC ID               Remarks
    A.       Notebook            Lenovo             81A4               YD02TWDP                     N/A         Provided by Lab
    B.         Load               N/A               N/A                    N/A                      N/A         Supplied by client
Note: All power cords of the above support units are non-shielded (1.8m).


                                                                        Shielding
    ID        Descriptions                Qty.        Length (m)                     Cores (Qty.)             Remarks
                                                                        (Yes/No)
    1.     USB to Type C cable                1            0.45            Y              0               Supplied by client
Note: The core(s) is(are) originally attached to the cable(s).


3.1.1      Configuration of System under Test
Charging Mode:


                                                                   Load (B)


                                          1
                Notebook (A)                                         EUT




Standby Mode:




                                          1
                Notebook (A)                                         EUT




Report No.: SA190716C36                                       Page No. 6 / 11                             Report Format Version: 6.1.1


3.2     Test Setup




                                                    15 cm




                                                                             EUT

                      Field Probe




Note: Measurements should be made from all sides and the top of the primary/client pair, with the 15 cm
     measured from the center of the probe(s) to the edge of the device.

3.3     Test Instruments

       Description         Brand     Model No.     Frequency Range Calibrated Date Calibrated Until
  Broadband Field
                          NARDA       NBM-550                  -       Mar. 28, 2018     Mar. 27, 2020
       Meter
   Magnetic Field
                          NARDA       ELT-400          1 – 400kHz      Apr. 12, 2018     Apr. 11, 2020
      Meter
  Magnetic Probe          NARDA       HF-3061       300kHz – 30MHz     Apr. 16, 2018     Apr. 15, 2020
  Magnetic Probe          NARDA       HF-0191        27 – 1000MHz      Apr. 17, 2018     Apr. 16, 2020
  Broadband Field
                          NARDA       NBM-550                  -       Mar. 28, 2018     Mar. 27, 2020
       Meter
Electric Field Meter COMBINOVA        EFM 200         5Hz – 400kHz      Dec. 6, 2017     Dec. 5, 2019
      E-Field Probe       NARDA       EF-0391        100kHz – 3GHz     Mar. 28, 2018     Mar. 27, 2020
      E-Field Probe       NARDA       EF-6091      100MHz – 60GHz      Mar. 29, 2018     Mar. 28, 2020

NOTE: 1. The calibration interval of the above test instruments is 12/24 months and the
          calibrations are traceable to NML/ROC and NIST/USA.
      2. The test was performed in Chia Pau RF Chamber
      3. Determining compliance based on the results of the compliance measurement, not taking into
         account measurement instrumentation uncertainty.




Report No.: SA190716C36                      Page No. 7 / 11                        Report Format Version: 6.1.1


3.4    Limits for Maximum Permissible Exposure (MPE)
§ 1.1310 The criteria listed in table 1 shall be used to evaluate the environmental impact of
  human exposure to radiofrequency(RF) radiation as specified in § 1.1307(b), except in the case of portable
  devices which shall be evaluated according to the provisions of § 2.1093 of this chapter.




680106 D01 RF Exposure Wireless Charging App v03
The aggregate H-field strengths at 15 cm surrounding the device and 15 cm above the top surface from all
simultaneous transmitting coils are demonstrated to be less than 50% of the MPE limit.

3.5    Test Point Description



                          Z-axis (Top)
                                         Top




      Left                                        Right




                 Bottom                    Z-axis (Bottom)




Report No.: SA190716C36                        Page No. 8 / 11                      Report Format Version: 6.1.1


4   Calculation Result of Maximum Conducted Power
Charging Mode with 90% Load
                                     E-Field Measurement
      Distance                                                    15cm
                                                                                    Z-axis          Z-axis
     EUT Side               Left       Right              Top            Bottom
                                                                                     Top            Bottom
 Max E-field (V/m)        0.5600      0.2500            0.1500           0.2200     0.2400          0.1900
     Limit (V/m)           60.77      60.77              60.77            60.77      60.77           60.77
   Margin (V/m)           -60.2100   -60.5200          -60.6200          -60.5500   -60.5300       -60.5800
  50 % Limit (V/m)        30.385      30.385            30.385           30.385     30.385          30.385
50 % Margin (V/m)         -29.8250   -30.1350          -30.2350          -30.1650   -30.1450       -30.1950

                                          H-Field Measurement
      Distance                                                    15cm
                                                                                    Z-axis          Z-axis
     EUT Side               Left       Right              Top            Bottom
                                                                                     Top            Bottom
 Max H-field (A/m)        0.0231      0.0201            0.0202           0.0205     0.0229          0.0186
     Limit (A/m)            0.16       0.16              0.16              0.16       0.16            0.16
   Margin (A/m)           -0.1369    -0.1399           -0.1398           -0.1395    -0.1371         -0.1414
  50 % Limit (A/m)          0.08       0.08              0.08              0.08       0.08            0.08
 50 % Margin (A/m)       -0.0569        -0.0599        -0.0598       -0.0595        -0.0571     -0.0614
Measurements were made from all sides and the top of the primary/client pair, with the 15 cm measured from
the center of the probe(s) to the edge of the device. The highest emission level was recorded.

Charging Mode with 50% Load
                                          E-Field Measurement
      Distance                                                    15cm
                                                                                    Z-axis          Z-axis
     EUT Side               Left       Right              Top            Bottom
                                                                                     Top            Bottom
 Max E-field (V/m)        0.4900      0.2000            0.1300           0.1900     0.1900          0.1500
     Limit (V/m)           60.77      60.77              60.77            60.77      60.77           60.77
   Margin (V/m)           -60.2800   -60.5700          -60.6400          -60.5800   -60.5800       -60.6200
  50 % Limit (V/m)        30.385      30.385            30.385           30.385     30.385          30.3850
50 % Margin (V/m)         -29.8950   -30.1850          -30.2550          -30.1950   -30.1950       -30.2350

                                          H-Field Measurement
      Distance                                                    15cm
                                                                                    Z-axis          Z-axis
     EUT Side               Left       Right              Top            Bottom
                                                                                     Top            Bottom
 Max H-field (A/m)        0.0201      0.0189            0.0194           0.0193     0.0227          0.0187
     Limit (A/m)            0.16       0.16              0.16              0.16       0.16            0.16
   Margin (A/m)           -0.1399     -0.1411          -0.1406           -0.1407    -0.1373         -0.1413
  50 % Limit (A/m)          0.08       0.08              0.08              0.08       0.08            0.08
 50 % Margin (A/m)       -0.0599        -0.0611        -0.0606       -0.0607        -0.0573     -0.0613
Measurements were made from all sides and the top of the primary/client pair, with the 15 cm measured from
the center of the probe(s) to the edge of the device. The highest emission level was recorded.



Report No.: SA190716C36                        Page No. 9 / 11                        Report Format Version: 6.1.1


Charging Mode with 10% Load
                                          E-Field Measurement
      Distance                                                    15cm
                                                                                    Z-axis          Z-axis
     EUT Side               Left       Right              Top            Bottom
                                                                                     Top            Bottom
 Max E-field (V/m)        0.4100      0.1800            0.1100           0.1600     0.1600          0.1200
     Limit (V/m)           60.77      60.77              60.77            60.77      60.77           60.77
   Margin (V/m)           -60.3600   -60.5900          -60.6600          -60.6100   -60.6100       -60.6500
  50 % Limit (V/m)        30.385      30.385            30.385           30.385     30.385          30.385
50 % Margin (V/m)         -29.9750   -30.2050          -30.2750          -30.2250   -30.2250       -30.2650

                                          H-Field Measurement
      Distance                                                    15cm
                                                                                    Z-axis          Z-axis
     EUT Side               Left       Right              Top            Bottom
                                                                                     Top            Bottom
 Max H-field (A/m)        0.0194      0.0181            0.0188           0.0186     0.0215          0.0174
     Limit (A/m)            0.16       0.16              0.16              0.16       0.16            0.16
   Margin (A/m)           -0.1406    -0.1419           -0.1412           -0.1414    -0.1385         -0.1426
  50 % Limit (A/m)          0.08       0.08              0.08              0.08       0.08            0.08
 50 % Margin (A/m)       -0.0606        -0.0619        -0.0612       -0.0614        -0.0585     -0.0626
Measurements were made from all sides and the top of the primary/client pair, with the 15 cm measured from
the center of the probe(s) to the edge of the device. The highest emission level was recorded.


Standby Mode
                                          E-Field Measurement
      Distance                                                    15cm
                                                                                    Z-axis          Z-axis
     EUT Side               Left       Right              Top            Bottom
                                                                                     Top            Bottom
 Max E-field (V/m)        0.2900      0.4400            0.1900           0.2200     0.0280          0.2400
     Limit (V/m)           60.77      60.77              60.77            60.77      60.77           60.77
   Margin (V/m)           -60.4800   -60.3300          -60.5800          -60.5500   -60.7420       -60.5300
  50 % Limit (V/m)        30.385      30.385            30.385           30.385     30.385          30.385
50 % Margin (V/m)         -30.0950   -29.9450          -30.1950          -30.1650   -30.3570       -30.1450

                                          H-Field Measurement
      Distance                                                    15cm
                                                                                    Z-axis          Z-axis
     EUT Side               Left       Right              Top            Bottom
                                                                                     Top            Bottom
 Max H-field (A/m)        0.0282      0.0183            0.0200           0.0195     0.0196          0.0153
     Limit (A/m)            0.16       0.16              0.16              0.16       0.16            0.16
   Margin (A/m)           -0.1318    -0.1417           -0.1400           -0.1405    -0.1404         -0.1447
  50 % Limit (A/m)          0.08       0.08              0.08              0.08       0.08            0.08
 50 % Margin (A/m)       -0.0518        -0.0617        -0.0600       -0.0605        -0.0604     -0.0647
Measurements were made from all sides and the top of the primary/client pair, with the 15 cm measured from
the center of the probe(s) to the edge of the device. The highest emission level was recorded.




Report No.: SA190716C36                        Page No. 10 / 11                       Report Format Version: 6.1.1


5    Photographs of the Test Configuration

Please refer to the attached file (Test Setup Photo).