12857633-S1V3 FCC Report_SAR

FCC ID: C3K1873

RF Exposure Info

Download: PDF
FCCID_4463888

  SAR EVALUATION REPORT

      IEEE Std 1528-2013

             For

  Portable Computing Device

      Model Name: 1873

 Report Number: 12857633-S1V3
     Issue Date: 9/24/2019

         Prepared for

    Microsoft Corporation
      One Microsoft Way
   Redmond, WA 98052 USA

         Prepared by

UL VERIFICATION SERVICES INC.
    47173 BENICIA STREET
   FREMONT, CA 94538, USA
      TEL: (510) 319-4000
      FAX: (510) 661-0888




      NVLAP LAB CODE 200065-0


Report No.:12857633 -S1V3                                                                        Issue Date: 9/24/2019

Revision History
 Rev.    Date             Revisions                                                        Revised By
 V1      9/11/2019        Initial Issue                                                    --
 V2      9/23/2019        Updated per TCB Reviewer Feedback                                Christopher Kuwatani
                          Section 9.2: Updated Targets
 V3      9/24/2019                                                                         Coltyce Sanders
                          Appendix B: Added system check plot




                                                    Page 2 of 24
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.:12857633 -S1V3                                                                                                    Issue Date: 9/24/2019

                                                               Table of Contents
1.          Attestation of Test Results ......................................................................................................... 4
2.          Test Specification, Methods and Procedures............................................................................ 5
3.          Facilities and Accreditation ........................................................................................................ 5
4.          SAR Measurement System & Test Equipment .......................................................................... 6
     4.1.      SAR Measurement System ........................................................................................................ 6
     4.2.      SAR Scan Procedures ............................................................................................................... 7
     4.3.      Test Equipment.......................................................................................................................... 9
5.          Measurement Uncertainty ........................................................................................................... 9
6.          Device Under Test (DUT) Information ...................................................................................... 10
     6.1.      DUT Description ...................................................................................................................... 10
     6.2.      Wireless Technologies ............................................................................................................. 10
7.          RF Exposure Conditions (Test Configurations) ...................................................................... 11
8.          Dielectric Property Measurements & System Check .............................................................. 12
     8.1.      Dielectric Property Measurements ........................................................................................... 12
     8.2.      System Check.......................................................................................................................... 14
9.          Conducted Output Power Measurements................................................................................ 15
     9.1.      Wi-Fi 2.4GHz (DTS Band) ....................................................................................................... 15
     9.2.      Wi-Fi 5GHz (U-NII Bands)........................................................................................................ 16
10.         Measured and Reported (Scaled) SAR Results ....................................................................... 19
     10.1.        Wi-Fi (DTS Band) ................................................................................................................. 20
     10.2.        Wi-Fi (U-NII Band) ................................................................................................................ 20
     10.3.        Standalone SAR Test Exclusion Considerations & Estimated SAR ...................................... 21
11.         SAR Measurement Variability ................................................................................................... 22
12.         Simultaneous Transmission SAR Analysis ............................................................................. 23
     12.1.        Sum of the SAR for Wi-Fi & BT ............................................................................................ 23
Appendixes .......................................................................................................................................... 24
     Appendix A: SAR Setup Photos ......................................................................................................... 24
     Appendix B: SAR System Check Plots ............................................................................................... 24
     Appendix C: SAR Highest Test Plots .................................................................................................. 24
     Appendix D: SAR Tissue Ingredients.................................................................................................. 24
     Appendix E: SAR Probe Certificates................................................................................................... 24
     Appendix F: SAR Dipole Certificates .................................................................................................. 24




                                                    Page 3 of 24
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.:12857633 —S1V3                                                                        Issue Date: $24/2019

1. Attestation of Test Results
                                   Microsoft Corporation
                                   C3K1873
                                   1873
                                   General Population/Uncontrolled Exposure
                                   Published RF exposure KDB procedures
                                   IEEE Std 1528—2013




                                   8/21/2019 to 8/23/2019 and 9/23/2019
                                   Pass

UL Verification Services Inc. tested the above equipmentin accordance with the requirements set forth in
the above standards. The test results show that the equipment tested is capable of demonstrating
compliance with the requirements as documented in this report.
The results documented in this report apply only to the tested sample, under the conditions and modes of
operation as described herein. It is the manufacturer‘s responsibility to assure that additional production
units of this model are manufactured with identical electrical and mechanical components. All samples
tested were in good operating condition throughout the entire test program. Measurement Uncertainties
are published for informational purposes only and were not taken into account unless noted otherwise.
This document may not be altered or revised in any way unless done so by UL Verification Services Inc.
and all revisions are duly noted in the revisions section. Any alteration of this document not carried out
by UL Verification Services Inc. will constitute fraud and shall nullify the document. This report must not
be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, any
agency of the Federal Government, or any agency of the U.S. government.
Approved & Released By:                                     Prepared By:


/,}@é@_                                                      Chaistophtit Xuwatani
Dave Weaver                                                 Christopher Kuwatani
Operations Leader                                           Laboratory Technician
UL Verification Services Inc.                               UL Verification Services Inc.




                                                    Page 4 of 24
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.:12857633 -S1V3                                                                        Issue Date: 9/24/2019

2. Test Specification, Methods and Procedures
The tests documented in this report were performed in accordance with FCC 47 CFR § 2.1093, IEEE STD 1528-
2013, the following FCC Published RF exposure KDB procedures:
   • KDB 865664 D01 (Section 3.5): SAR Measurement 100 MHz to 6 GHz v01r04
   • KDB 248227 D01: 802.11 Wi-Fi SAR v02r02
   • KDB 447498 D01: General RF exposure Guidance v06 (see Notice-DRS0001 for exemptions)
   • KDB 616217 D04: SAR for Laptops and Tablets v01r02
In addition to the above, the following information was used:
    o   TCB workshop October 2016; RF Exposure Procedures (DUT Holder Perturbations)
    o   TCB workshop May 2017; RF Exposure Procedures (Broadband Liquid Above 3 GHz)
    o   TCB workshop April 2019; RF Exposure Procedures (Tissue Simulating Liquids (TSL))
    o   TCB workshop October 2016; RF Exposure Procedures (Bluetooth Duty Factor)

3. Facilities and Accreditation
The test sites and measurement facilities used to collect data are located at

             47173 Benicia Street                             47266 Benicia Street
                  SAR Lab A                                        SAR Lab 1
                  SAR Lab B                                        SAR Lab 2
                  SAR Lab C                                        SAR Lab 3
                  SAR Lab D                                        SAR Lab 4
                  SAR Lab E                                        SAR Lab 5
                  SAR Lab F                                        SAR Lab 6
                  SAR Lab G                                        SAR Lab 7
                  SAR Lab H                                        SAR Lab 8
UL Verification Services Inc. is accredited by NVLAP, Laboratory Code 200065-0.




                                                    Page 5 of 24
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


remute mss ous                                                 inpersoums
4. SAF Measurement System & Test Exuipment
411. SAR Mexsurement System




+.   sn hoh amsmontaneraotwth contles epetanian sls A amasmanr
     nommeciley be in masutenoicoes hE
+.   Annolone t ncbeosimant antcalnalob aguis namumnent
+    Adiincsntanatetones BAS uhh anfom besaralanallalon sautnoteminn 10
     coneat obnemuonani, mastanesotac ooo whrorcopnion an Th uin iley
     omen wiliianan o nctagnic Satatns    Th eova mopintbarmialo h E0
+.   hiErnionteatconsinlEGprsira       n conattn tm anico snctealsevas t e
     Ehncioh 6Ve DXe Ton hitinsopmmaorol ie Goon o ts
     €09 spraln tanwndet s te nemsunnetsonec
+.   Th latanol n neasunnatsant ornho m orialists ucasoIdama cotnf
     bo nbiopntcnin ininowrort nenws
+    The Lo am ioi omowe atgnnent Thnorn n assite)nac t e n muteeo
+.   Acemiie inNt oHa?and b OASISaneare
3.   Ravallcorslannpenan o vatm aitteatomaty t insl uco varin m
4.   Ti sds tm aove iacarandoher monnorms azortng o e lngens remonran




                          rameoine
Wmmsms                                               sxerrs
  Th asalavalostte mt witotm t ecroa t t Yrtcton Sn n


Report No.:12857633 -S1V3                                                                        Issue Date: 9/24/2019

4.2. SAR Scan Procedures
Step 1: Power Reference Measurement
The Power Reference Measurement and Power Drift Measurements are for monitoring the power drift of the device
under test in the batch process. The minimum distance of probe sensors to surface determines the closest
measurement point to phantom surface. The minimum distance of probe sensors to surface is 2.1 mm. This
distance cannot be smaller than the distance of sensor calibration points to probe tip as defined in the probe
properties.

Step 2: Area Scan
The Area Scan is used as a fast scan in two dimensions to find the area of high field values, before doing a fine
measurement around the hot spot. The sophisticated interpolation routines implemented in DASY software can find
the maximum locations even in relatively coarse grids. When an Area Scan has measured all reachable points, it
computes the field maximal found in the scanned area, within a range of the global maximum. The range (in dB) is
specified in the standards for compliance testing. For example, a 2 dB range is required in IEEE Standard 1528
and IEC 62209 standards, whereby 3 dB is a requirement when compliance is assessed in accordance with the
ARIB standard (Japan). If only one Zoom Scan follows the Area Scan, then only the absolute maximum will be
taken as reference. For cases where multiple maximums are detected, the number of Zoom Scans has to be
increased accordingly.
Area Scan Parameters extracted from KDB 865664 D01 SAR Measurement 100 MHz to 6 GHz




                                                    Page 7 of 24
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.:12857633 -S1V3                                                                        Issue Date: 9/24/2019
Step 3: Zoom Scan
Zoom Scans are used to assess the peak spatial SAR values within a cubic averaging volume containing 1 g and
10 g of simulated tissue. The Zoom Scan measures points (refer to table below) within a cube whose base faces
are centered on the maxima found in a preceding area scan job within the same procedure. When the
measurement is done, the Zoom Scan evaluates the averaged SAR for 1 g and 10 g and displays these values
next to the job’s label.
Zoom Scan Parameters extracted from KDB 865664 D01 SAR Measurement 100 MHz to 6 GHz




Step 4: Power drift measurement
The Power Drift Measurement measures the field at the same location as the most recent power reference
measurement within the same procedure, and with the same settings. The Power Drift Measurement gives the field
difference in dB from the reading conducted within the last Power Reference Measurement. This allows a user to
monitor the power drift of the device under test within a batch process. The measurement procedure is the same as
Step 1.




                                                    Page 8 of 24
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.:12857633 -S1V3                                                                           Issue Date: 9/24/2019

4.3. Test Equipment
The measuring equipment used to perform the tests documented in this report has been calibrated in accordance
with the manufacturers’ recommendations and is traceable to recognized national standards.
Dielectric Property Measurements
Name of Equipment                                 Manufacturer      Type/Model         Serial No.        Cal. Due Date
Vector Network Analyzer                          Rhode & Schwarz      ZNLE6            101273-va          4/24/2020
Dielectric Probe kit                                 SPEAG           DAK-3.5             1103             2/12/2020
Shorting Block*                                      SPEAG         DAK-3.5 Short    SM DAK 200 DA         9/11/2019
Shorting Block                                      SPEAG          DAK-3.5 Short    SM DAK 200 DA         11/6/2019
Thermometer                                         Keysight        Traceable         170064398           5/21/2020


Notes:
*Equipment not used past calibration due date.

System Check
Name of Equipment                                  Manufacturer     Type/Model         Serial No.        Cal. Due Date
Signal Generator                                 Rhode & Schwarz     SMB100A           180969-yC           2/13/2020
Power Sensor                                     Rhode & Schwarz     NRP18A            100995-hs           2/15/2020
Signal Generator                                 Rhode & Schwarz     SMB100A           180968-gX           2/14/2020
Power Sensor                                     Rhode & Schwarz     NRP18A            100992-iu           2/15/2020


Lab Equipment
Name of Equipment                                  Manufacturer     Type/Model         Serial No.        Cal. Due Date
E-Field Probe (SAR Lab 1)                            SPEAG           EX3DV4              3885              9/18/2019
E-Field Probe (SAR Lab 3)                            SPEAG           EX3DV4              7500              4/18/2020
Data Acquisition Electronics (SAR Lab 1)             SPEAG             DAE4              1544              3/19/2020
Data Acquisition Electronics (SAR Lab 3)             SPEAG             DAE4              1472              3/21/2020
System Validation Dipole                             SPEAG           D2450V2             899               3/22/2020
System Validation Dipole                             SPEAG           D5GHzV2             1168             11/30/2019
System Validation Dipole                             SPEAG           D5GHzV2             1003              2/19/2020


Other
Name of Equipment                                  Manufacturer     Type/Model         Serial No.        Cal. Due Date
Power Meter                                          Agilent          N1921A          MY55196004           1/30/2020
Power Sensor                                         Agilent          N1921A          MY52270022           2/6/2020
Power Sensor                                         Agilent          N1921A          MY53260010           2/6/2020




5. Measurement Uncertainty
Per KDB 865664 D01 SAR Measurement 100 MHz to 6 GHz, when the highest measured 1-g SAR within a
frequency band is < 1.5 W/kg and the measured 10-g SAR within a frequency band is < 3.75 W/kg. The expanded
SAR measurement uncertainty must be ≤ 30%, for a confidence interval of k = 2. If these conditions are met,
extensive SAR measurement uncertainty analysis described in IEEE Std 1528-2013 is not required in SAR reports
submitted for equipment approval.
Therefore, the measurement uncertainty is not required.




                                                    Page 9 of 24
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.:12857633 -S1V3                                                                                      Issue Date: 9/24/2019

6. Device Under Test (DUT) Information
6.1.       DUT Description
 Device Dimension             See Appendix A

 Battery Options              The battery is not user accessible.

 Accessory                    N/A

                                        S/N                         IMEI                            Notes

 Test sample information            009078492757                    N/A                     WLAN Radiated/Conducted

                                    009055292757                    N/A                     WLAN Radiated/Conducted

 Hardware Version             DV

 Software Version             18362.19h1

6.2.       Wireless Technologies
       Wireless                                                                                         Duty Cycle used for SAR
                           Frequency bands                                 Operating mode
     technologies                                                                                               testing
                                                     802.11b
                                                     802.11g
                      2.4 GHz                                                                        DTS: 99.03% (802.11b) 1
                                                     802.11n (HT20)
                                                     802.11n (HT40)
                                                     802.11a
                                                     802.11n (HT20)
 Wi-Fi                                               802.11n (HT40)                                  UNII-2A: 90.37% (802.11n 40MHz BW) 1
                      5 GHz
                                                     802.11ac (VHT20)                                UNII-3: 82.72% (802.11ac 80MHz BW) 1
                                                     802.11ac (VHT40)
                                                     802.11ac (VHT80)
                      Bluetooth                      BR, EDR, LE                                     N/A2
                      Does this device support bands 5.60 ~ 5.65 GHz? ☒ Yes ☐ No
                      Does this device support Band gap channel(s)? ☒ Yes ☐ No


Notes:
1.    Duty cycle for Wi-Fi is referenced from the DTS and UNII reports.
2.    Measured Duty Cycle is not required due to SAR test exemption.




                                                   Page 10 of 24
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.:12857633 -S1V3                                                                        Issue Date: 9/24/2019

7. RF Exposure Conditions (Test Configurations)
Refer to Appendix A for the specific details of the antenna-to-antenna and antenna-to-edge(s) distances.
     Wireless          RF Exposure         DUT-to-User            Test             Antenna-to-           SAR
   technologies         Conditions          Separation           Position         edge/surface         Required
     WLAN/BT
                        Standalone            0 mm                Rear               N/A                 Yes
      ANT 1
      WLAN
                        Standalone            0 mm                Rear               N/A                 Yes
      ANT 2




                                                   Page 11 of 24
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.:12857633 -S1V3                                                                        Issue Date: 9/24/2019

8. Dielectric Property Measurements & System Check
8.1.    Dielectric Property Measurements
The temperature of the tissue-equivalent medium used during measurement must also be within 18°C to 25°C and
within ± 2°C of the temperature when the tissue parameters are characterized.
The dielectric parameters must be measured before the tissue-equivalent medium is used in a series of SAR
measurements. The parameters should be re-measured after each 3 – 4 days of use; or earlier if the dielectric
parameters can become out of tolerance; for example, when the parameters are marginal at the beginning of the
measurement series.
Tissue dielectric parameters were measured at the low, middle and high frequency of each operating frequency
range of the test device.
The dielectric constant (εr) and conductivity (σ) of typical tissue-equivalent media recipes are expected to
be within ± 5% of the required target values; but for SAR measurement systems that have implemented the SAR
error compensation algorithms documented in IEEE Std 1528-2013, to automatically compensate the measured
SAR results for deviations between the measured and required tissue dielectric parameters, the tolerance for εr and
σ may be relaxed to ± 10%. This is limited to frequencies ≤ 3 GHz.

Tissue Dielectric Parameters
FCC KDB 865664 D01 SAR Measurement 100 MHz to 6 GHz
                                               Head                                      Body
    Target Frequency (MHz)
                                      εr                 σ (S/m)                εr                 σ (S/m)
             150                     52.3                 0.76                 61.9                 0.80
             300                     45.3                 0.87                 58.2                 0.92
             450                     43.5                 0.87                 56.7                 0.94
             835                     41.5                 0.90                 55.2                 0.97
             900                     41.5                 0.97                 55.0                 1.05
             915                     41.5                 0.98                 55.0                 1.06
            1450                     40.5                 1.20                 54.0                 1.30
            1610                     40.3                 1.29                 53.8                 1.40
         1800 – 2000                 40.0                 1.40                 53.3                 1.52
            2450                     39.2                 1.80                 52.7                 1.95
            3000                     38.5                 2.40                 52.0                 2.73
            5000                     36.2                 4.45                 49.3                 5.07
            5100                     36.1                 4.55                 49.1                 5.18
            5200                     36.0                 4.66                 49.0                 5.30
            5300                     35.9                 4.76                 48.9                 5.42
            5400                     35.8                 4.86                 48.7                 5.53
            5500                     35.6                 4.96                 48.6                 5.65
            5600                     35.5                 5.07                 48.5                 5.77
            5700                     35.4                 5.17                 48.3                 5.88
            5800                     35.3                 5.27                 48.2                 6.00


IEEE Std 1528-2013
Refer to Table 3 within the IEEE Std 1528-2013




                                                   Page 12 of 24
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.:12857633 -S1V3                                                                                     Issue Date: 9/24/2019
Dielectric Property Measurements Results:

                                                       Relative Perm ittivity (єr)                   Conductivity (σ)
   SAR                  Band    Tissue   Frequency
             Date                                                              Delta                                    Delta
   Lab                 (MHz)     Type      (MHz)   Measured     Target                    Measured       Target
                                                                                  (%)                                    (%)

                                            2450        50.74       52.70         -3.72     2.01           1.95         3.28
    1      8/21/2019   2450      Body       2400        50.80       52.77         -3.74     1.97           1.90         3.79
                                            2480        50.76       52.66         -3.61     2.03           1.99         1.85
                                                          Relative Perm ittivity (єr)                Conductivity (σ)
   SAR                  Band    Tissue   Frequency
             Date                                                                Delta                                  Delta
   Lab                 (MHz)     Type      (MHz)   Measured        Target                 Measured       Target
                                                                                  (%)                                    (%)

                                            5250        47.91       48.95         -2.13     5.32           5.35         -0.58
    3      8/22/2019   5250      Body       5150        48.12       49.09         -1.97     5.18           5.24         -1.17
                                            5350        47.74       48.82         -2.20     5.45           5.47         -0.32
                                            5600        47.28       48.48         -2.47     5.81           5.76         0.83
    3      8/22/2019   5600      Body       5500        47.46       48.61         -2.37     5.66           5.64         0.33
                                            5725        47.06       48.31         -2.58     5.98           5.91         1.21
                                            5750        46.98       48.27         -2.68     6.01           5.94         1.28
    3      8/22/2019   5750      Body       5700        47.11       48.34         -2.55     5.95           5.88         1.27
                                            5850        46.79       48.20         -2.93     6.16           6.00         2.60
                                            5600        48.17       48.48         -0.63     5.53           5.76         -4.10
    3      9/10/2019   5600      Body       5500        48.33       48.61         -0.58     5.38           5.64         -4.63
                                            5725        47.91       48.31         -0.82     5.71           5.91         -3.28
                                            5250        48.52       48.95         -0.88     5.14           5.35         -4.02
    3      9/10/2019   5250      Body       5150        48.72       49.09         -0.75     5.00           5.24         -4.55
                                            5350        48.35       48.82         -0.96     5.26           5.47         -3.78
                                            5600        47.36       48.48         -2.31     5.81           5.76         0.78
    3      9/23/2019   5600      Body       5500        47.53       48.61         -2.23     5.66           5.64         0.22
                                            5725        47.12       48.31         -2.46     6.00           5.91         1.53




                                                   Page 13 of 24
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.:12857633 -S1V3                                                                                                                           Issue Date: 9/24/2019

8.2.         System Check
SAR system verification is required to confirm measurement accuracy, according to the tissue dielectric media,
probe calibration points and other system operating parameters required for measuring the SAR of a test device.
The system verification must be performed for each frequency band and within the valid range of each probe
calibration point required for testing the device. The same SAR probe(s) and tissue-equivalent media combinations
used with each specific SAR system for system verification must be used for device testing. When multiple probe
calibration points are required to cover substantially large transmission bands, independent system verifications are
required for each probe calibration point. A system verification must be performed before each series of SAR
measurements using the same probe calibration point and tissue-equivalent medium. Additional system verification
should be considered according to the conditions of the tissue-equivalent medium and measured tissue dielectric
parameters, typically every three to four days when the liquid parameters are re-measured or sooner when
marginal liquid parameters are used at the beginning of a series of measurements.

System Performance Check Measurement Conditions:
•        The measurements were performed in the flat section of the TWIN SAM or ELI phantom, shell thickness: 2.0
         ±0.2 mm (bottom plate) filled with Body or Head simulating liquid of the following parameters.
•        The depth of tissue-equivalent liquid in a phantom must be ≥ 15.0 cm for SAR measurements ≤ 3 GHz and ≥
         10.0 cm for measurements > 3 GHz.
•        The DASY system with an E-Field Probe was used for the measurements.
•        The dipole was mounted on the small tripod so that the dipole feed point was positioned below the center
         marking of the flat phantom section and the dipole was oriented parallel to the body axis (the long side of the
         phantom). The standard measuring distance was 10 mm (above 1 GHz) and 15 mm (below 1 GHz) from dipole
         center to the simulating liquid surface.
•        The coarse grid with a grid spacing of 15 mm was aligned with the dipole.
         For 5 GHz band - The coarse grid with a grid spacing of 10 mm was aligned with the dipole.
•        Special 7x7x7 (below 3 GHz) and/or 8x8x7 (above 3 GHz) fine cube was chosen for the cube.
•        Distance between probe sensors and phantom surface was set to 3 mm.
         For 5 GHz band - Distance between probe sensors and phantom surface was set to 2.5 mm
•        The dipole input power (forward power) was 100 mW.
•        The results are normalized to 1 W input power.

System Check Results
The 1-g and 10-g SAR measured with a reference dipole, using the required tissue-equivalent medium at the test
frequency, must be within ±10% of the manufacturer calibrated dipole SAR target. Refer to Appendix B for the SAR
System Check Plots.

                                                                                        Measured Results for 1g SAR                      Measured Results for 10g SAR
    SAR                 Tissue           Dipole Type             Dipole                                                                                                         Plot
              Date
    Lab                  Type             _Serial #           Cal. Due Data   Zoom Scan     Normalize     Target       Delta   Zoom Scan     Normalize     Target       Delta   No.
                                                                              to 100 mW      to 1 W     (Ref. Value)   ±10 %   to 100 mW      to 1 W     (Ref. Value)   ±10 %

     1      8/21/2019   Body          D2450V2 SN:899           3/22/2020        5.450         54.50        50.00       9.00      2.510         25.10        23.50       6.81     1,2

                                                                                        Measured Results for 1g SAR                      Measured Results for 10g SAR
    SAR                 Tissue           Dipole Type             Dipole                                                                                                         Plot
              Date
    Lab                  Type             _Serial #           Cal. Due Data   Zoom Scan     Normalize     Target       Delta   Zoom Scan     Normalize     Target       Delta   No.
                                                                              to 100 mW      to 1 W     (Ref. Value)   ±10 %   to 100 mW      to 1 W     (Ref. Value)   ±10 %

     3      8/22/2019   Body     D5GHzV2 SN:1168 (5.25 GHz)   11/30/2019        7.750         77.50        71.20       8.85      2.180         21.80        19.90       9.55     3,4

     3      8/22/2019   Body     D5GHzV2 SN:1168 (5.60 GHz)   11/30/2019        8.330         83.30        76.20       9.32      2.310         23.10        21.20       8.96     5,6

     3      8/22/2019   Body     D5GHzV2 SN:1168 (5.75 GHz)   11/30/2019        7.590         75.90        70.70       7.36      2.110         21.10        19.70       7.11     7,8

     3      9/10/2019   Body     D5GHzV2 SN:1003 (5.60 GHz)    2/19/2020        8.290         82.90        79.30       4.54      2.330         23.30        22.30       4.48    9,10

     3      9/10/2019   Body     D5GHzV2 SN:1003 (5.25 GHz)    2/19/2020        6.730         67.30        74.40       -9.54     1.890         18.90        20.80       -9.13   11,12

     3      9/23/2019   Body     D5GHzV2 SN:1003 (5.60 GHz)    2/19/2020        8.110         81.10        79.30       2.27      2.300         23.00        22.30       3.14    13,14




                                                   Page 14 of 24
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.:12857633 -S1V3                                                                                  Issue Date: 9/24/2019

9. Conducted Output Power Measurements
9.1.      Wi-Fi 2.4GHz (DTS Band)
Maximum Output Power (Tune-up Limit) for Wi-Fi 2.4 GHz
The maximum output power specified for production units are determined for all applicable 802.11 transmission
modes in each standalone and aggregated frequency band. Maximum output power is measured for the highest
maximum output power configuration(s) in each frequency band according to the default power measurement
procedures.
For “Not required”, SAR Test reduction was applied from KDB 248227 guidance, Sec. 2.1, b), 1) when the same
maximum power is specified for multiple transmission modes in a frequency band, the largest channel bandwidth,
lowest order modulation, lowest data rate and lowest order 802.11b/g/n mode is used for SAR measurement, on
the highest measured output power channel in the initial test configuration, for each frequency band. Additional
output power measurements were not deemed necessary.


Wi-Fi 2.4GHz Measured Results
                                                  ANT1 Average Pow er (dBm )          ANT 2 Average Pow er (dBm )
                                      Freq.
   Band       Mode        Ch #                                         SAR Test                              SAR Test
                                     (MHz)    Meas Pw r      Tune-up              Meas Pw r      Tune-up
                                                                       (Yes/No)                              (Yes/No)
                           1         2412         15.9        16.5                    16.3        16.5
                           2         2417         18.1        18.5                    18.2        18.5
                           6         2437         18.1        18.5                    18.5        18.5
   DSSS                    9         2452         18.1        18.5                    18.4        18.5
             802.11b                                                     Yes                                   Yes
  2.4 GHz                  10        2457     Not Required    18.5                Not Required    18.5
                           11        2462     Not Required    15.0                Not Required    15.0
                           12        2467     Not Required    14.5                Not Required    14.5
                           13        2472     Not Required    13.5                Not Required    13.5
                           1         2412                     16.5                                16.5
                           2         2417                     18.5                                18.5
                           6         2437                     18.5                                18.5
                           9         2452                     18.5                                18.5
             802.11g                                                      No                                    No
                           10        2457                     18.5                                18.5
                           11        2462                     15.0                                15.0
                           12        2467                     14.5                                14.5
                           13        2472                     13.5                                13.5
                           1         2412                     16.5                                16.5
                           2         2417                     18.5                                18.5
   OFDM
                           6         2437                     18.5                                18.5
  2.4 GHz
             802.11n       9         2452                     18.5                                18.5
                                                                          No                                    No
              (HT20)       10        2457                     18.5                                18.5
                           11        2462                     15.0                                15.0
                           12        2467                     14.5                                14.5
                           13        2472                     13.5                                13.5
                           3         2422                     18.5                                18.5
                           6         2437                     18.5                                18.5
             802.11n
                           9         2452                     18.5        No                      18.5          No
              (HT40)
                           10        2457                     18.5                                18.5
                           11        2462                     15.0                                15.0


Note(s):
SAR is not required for channel 12 and 13 because the tune-up limit and the measured output power for these two channels are
not greater than those for the default test channels. Refer to KDB 248227 D01 section 3.1




                                                   Page 15 of 24
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.:12857633 -S1V3                                                                        Issue Date: 9/24/2019

9.2.    Wi-Fi 5GHz (U-NII Bands)
Maximum Output Power (Tune-up Limit) for Wi-Fi 5 GHz
When the same transmission mode configurations have the same maximum output power on the same channel for
the 802.11 a/n/ac modes, the channel in the lower order/sequence 802.11 transmission mode is selected.
The maximum output power specified for production units are determined for all applicable 802.11 transmission
modes in each standalone and aggregated frequency band. Maximum output power is measured for the highest
maximum output power configuration(s) in each frequency band according to the default power measurement
procedures.
For “Not required”, SAR Test reduction was applied from KDB 248227 guidance, Sec. 2.1, b), 1) when the same
maximum power is specified for multiple transmission modes in a frequency band, the largest channel bandwidth,
lowest order modulation, lowest data rate and lowest order 802.11a/g/n/ac/ax mode is used for SAR measurement,
on the highest measured output power channel in the initial test configuration, for each frequency band. Additional
output power measurements were not deemed necessary.
When the specified maximum output power is the same for both UNII 1 and UNII 2A, begin SAR measurements in
UNII 2A with the channel with the highest measured output power. If the reported SAR for UNII 2A is ≤ 1.2 W/kg,
SAR is not required for UNII 1; otherwise treat the remaining bands separately and test them independently for
SAR.




                                                   Page 16 of 24
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.:12857633 -S1V3                                                                        Issue Date: 9/24/2019
Wi-Fi 5 GHz Measured Results
                                                  ANT 1 Average Pow er (dBm )        ANT 2 Average Pow er (dBm )
                                      Freq.
   Band        Mode       Ch #                                         SAR Test                           SAR Test
                                     (MHz)     Meas Pw r    Tune-up               Meas Pw r    Tune-up
                                                                       (Yes/No)                           (Yes/No)
                           36         5180                    9.5                                 9.5
                           40         5200                    9.5                                 9.5
              802.11a                                                     No                                 No
                           44         5220                    9.5                                 9.5
                           48         5240                    9.5                                 9.5
                           36         5180                    10.0                               10.0
              802.11n      40         5200                    10.0                               10.0
                                                                          No                                 No
               (HT20)      44         5220                    10.0                               10.0
                           48         5240                    10.0                               10.0
   UNII-1                  36         5180                    10.0                               10.0
  5.2 GHz                  40         5200                    10.0                               10.0
             802.11ac
                                                                          No                                 No
             (VHT20)       44         5220                    10.0                               10.0
                           48         5240                    10.0                               10.0
              802.11n      38         5190                    11.5                               11.5
                                                                          No                                 No
               (HT40)      46         5230                    11.5                               11.5
             802.11ac      38         5190                    11.5                               11.5
                                                                          No                                 No
             (VHT40)       46         5230                    11.5                               11.5
             802.11ac
                           42         5210                    11.5        No                     11.5        No
             (VHT80)
                                                  ANT 1 Average Pow er (dBm )        ANT 2 Average Pow er (dBm )
                                      Freq.
   Band        Mode       Ch #                                         SAR Test                           SAR Test
                                     (MHz)     Meas Pw r    Tune-up               Meas Pw r    Tune-up
                                                                       (Yes/No)                           (Yes/No)
                           52         5260                    14.0                               14.0
                           56         5280                    14.0                               14.0
              802.11a                                                     No                                 No
                           60         5300                    14.0                               14.0
                           64         5320                    14.0                               14.0
                           52         5260                    14.0                               14.0
              802.11n      56         5280                    14.0                               14.0
                                                                          No                                 No
               (HT20)      60         5300                    14.0                               14.0
                           64         5320                    14.0                               14.0
  UNII-2A                  52         5260                    14.0                               14.0
  5.3 GHz                  56         5280                    14.0                               14.0
             802.11ac
                                                                          No                                 No
             (VHT20)       60         5300                    14.0                               14.0
                           64         5320                    14.0                               14.0
              802.11n      54         5270        16.2        16.5                   16.3        16.5
                                                                         Yes                                 Yes
               (HT40)      62         5310        16.3        16.5                   16.4        16.5
             802.11ac      54         5270                    16.5                               16.5
                                                                          No                                 No
             (VHT40)       62         5310                    16.5                               16.5
             802.11ac
                           58         5290                    14.5        No                     14.5        No
             (VHT80)




                                                   Page 17 of 24
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.:12857633 -S1V3                                                                         Issue Date: 9/24/2019
Wi-Fi 5 GHz Measured Results (continued)
                                                    ANT 1 Average Power (dBm)           ANT 2 Average Power (dBm)
                                       Freq.
   Band        Mode        Ch #                                          SAR Test                            SAR Test
                                      (MHz)     Meas Pwr     Tune-up                Meas Pwr     Tune-up
                                                                         (Yes/No)                            (Yes/No)
                           104        5500                     15.0                                15.0
                           116        5580                     15.0                                15.0
              802.11a                                                       No                                  No
                           140        5700                     15.0                                15.0
                           144        5720                     15.0                                15.0
                           104        5500                     15.0                                15.0
              802.11n      116        5580                     15.0                                15.0
                                                                            No                                  No
              (HT20)       140        5700                     15.0                                15.0
                           144        5720                     15.0                                15.0
                           104        5500                     15.0                                15.0
             802.11ac      116        5580                     15.0                                15.0
                                                                            No                                  No
             (VHT20)       140        5700                     15.0                                15.0
  UNII-2C
                           144        5720                     15.0                                15.0
  5.5 GHz
                           102        5510                     15.5                                15.5
              802.11n      110        5550                     15.5                                15.5
                                                                            No                                  No
              (HT40)       134        5670                     15.5                                15.5
                           142        5710                     16.5                                16.5
                           102        5510                     15.5                                15.5
             802.11ac      110        5550                     15.5                                15.5
                                                                            No                                  No
             (VHT40)       134        5670                     15.5                                15.5
                           142        5710                     16.5                                16.5
                           106        5530                     13.5                                13.5
             802.11ac
                           122        5610                     13.5        Yes                     13.5        Yes
             (VHT80)
                           138        5690        16.5         16.5                   16.5         16.5
                                                    ANT 1 Average Power (dBm)           ANT 2 Average Power (dBm)
                                       Freq.
   Band        Mode        Ch #                                          SAR Test                            SAR Test
                                      (MHz)     Meas Pwr     Tune-up                Meas Pwr     Tune-up
                                                                         (Yes/No)                            (Yes/No)
                           149        5745                     16.5                                16.5
              802.11a      157        5785                     16.5         No                     16.5         No
                           165        5825                     16.5                                16.5
                           149        5745                     16.5                                16.5
              802.11n
                           157        5785                     16.5         No                     16.5         No
              (HT20)
                           165        5825                     16.5                                16.5
                           149        5745                     16.5                                16.5
   UNII-3    802.11ac
  5.8 GHz                  157        5785                     16.5         No                     16.5         No
             (VHT20)
                           165        5825                     16.5                                16.5
              802.11n      151        5755                     16.5                                16.5
                                                                            No                                  No
              (HT40)       159        5795                     16.5                                16.5
             802.11ac      151        5755                     16.5                                16.5
                                                                            No                                  No
             (VHT40)       159        5795                     16.5                                16.5
             802.11ac
                           155        5775        16.4         16.5        Yes        16.4         16.5        Yes
             (VHT80)




                                                   Page 18 of 24
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.:12857633 -S1V3                                                                                     Issue Date: 9/24/2019

10.      Measured and Reported (Scaled) SAR Results
SAR Test Reduction criteria are as follows:
•   Reported SAR(W/kg) for Wi-Fi = Measured SAR * Tune-up scaling factor * Duty Cycle scaling factor
•   Duty Cycle scaling factor = 1 / Duty cycle (%)

KDB 447498 D01 General RF Exposure Guidance:
Testing of other required channels within the operating mode of a frequency band is not required when the reported 1-g or 10-g
SAR for the mid-band or highest output power channel is:
•   ≤ 0.8 W/kg or 2.0 W/kg, for 1-g or 10-g respectively, when the transmission band is ≤ 100 MHz
•   ≤ 0.6 W/kg or 1.5 W/kg, for 1-g or 10-g respectively, when the transmission band is between 100 MHz and 200 MHz
•   ≤ 0.4 W/kg or 1.0 W/kg, for 1-g or 10-g respectively, when the transmission band is ≥ 200 MHz

KDB 248227 D01 SAR meas for 802.11:
SAR test reduction for 802.11 Wi-Fi transmission mode configurations are considered separately for DSSS and OFDM. An initial
test position is determined to reduce the number of tests required for certain exposure configurations with multiple test positions.
An initial test configuration is determined for each frequency band and aggregated band according to maximum output power,
channel bandwidth, wireless mode configurations and other operating parameters to streamline the measurement requirements.
For 2.4 GHz DSSS, either the initial test position or DSSS procedure is applied to reduce the number of SAR tests; these are
mutually exclusive. For OFDM, an initial test position is only applicable to next to the ear, UMPC mini-tablet and hotspot mode
configurations, which is tested using the initial test configuration to facilitate test reduction. For other exposure conditions with a
fixed test position, SAR test reduction is determined using only the initial test configuration.
     The multiple test positions require SAR measurements in head, hotspot mode or UMPC mini-tablet configurations may be
reduced according to the highest reported SAR determined using the initial test position(s) by applying the DSSS or OFDM SAR
measurement procedures in the required wireless mode test configuration(s). The initial test position(s) is measured using the
highest measured maximum output power channel in the required wireless mode test configuration(s). When the reported SAR
for the initial test position is:

    •    ≤ 0.4 W/kg, further SAR measurement is not required for the other test positions in that exposure configuration and
         wireless mode combination within the frequency band or aggregated band. DSSS and OFDM configurations are
         considered separately according to the required SAR procedures.
    •    > 0.4 W/kg, SAR is repeated using the same wireless mode test configuration tested in the initial test position to
         measure the subsequent next closet/smallest test separation distance and maximum coupling test position, on the
         highest maximum output power channel, until the reported SAR is ≤ 0.8 W/kg or all required test positions are tested.
         o For subsequent test positions with equivalent test separation distance or when exposure is dominated by coupling
              conditions, the position for maximum coupling condition should be tested.
         o When it is unclear, all equivalent conditions must be tested.
    •    For all positions/configurations tested using the initial test position and subsequent test positions, when the reported
         SAR is > 0.8 W/kg, measure the SAR for these positions/configurations on the subsequent next highest measured
         output power channel(s) until the reported SAR is ≤ 1.2 W/kg or all required test channels are considered.
         o The additional power measurements required for this step should be limited to those necessary for identifying
              subsequent highest output power channels to apply the test reduction.
    •    When the specified maximum output power is the same for both UNII 1 and UNII 2A, begin SAR measurements in UNII
         2A with the channel with the highest measured output power. If the reported SAR for UNII 2A is ≤ 1.2 W/kg, SAR is not
         required for UNII 1; otherwise treat the remaining bands separately and test them independently for SAR.
    •    When the specified maximum output power is different between UNII 1 and UNII 2A, begin SAR with the band that has
         the higher specified maximum output. If the highest reported SAR for the band with the highest specified power is ≤
         1.2 W/kg, testing for the band with the lower specified output power is not required; otherwise test the remaining bands
         independently for SAR.




                                                   Page 19 of 24
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.:12857633 -S1V3                                                                                  Issue Date: 9/24/2019

10.1. Wi-Fi (DTS Band)
                                                                                        Pow er (dBm)      1-g SAR (W/kg)
RF Exposure               Dist.    Test               Freq.                                                                 Plot
               Mode                          Ch #.            Duty Cycle   Antenna   Tune-up
 Conditions              (mm)     Position           (MHz)                                       Meas.   Meas.     Scaled   No.
                                                                                       Limit
                                                                            ANT 1     18.5       18.1    0.367     0.411
              802.11b
 Standalone                0       Rear       6      2437      99.03%                                                        1
              1 Mbps
                                                                            ANT 2     18.5       18.5    0.336     0.342




10.2. Wi-Fi (U-NII Band)
                                                                                        Pow er (dBm)      1-g SAR (W/kg)
RF Exposure               Dist.    Test               Freq.                                                                 Plot
               Mode                          Ch #.            Duty Cycle   Antenna   Tune-up
 Conditions              (mm)     Position           (MHz)                                       Meas.   Meas.     Scaled   No.
                                                                                       Limit
                                                                            ANT 1     16.5       16.3    0.536     0.627
              802.11n
 Standalone                0       Rear      62      5310      90.37%                                                        2
               HT40
                                                                            ANT 2     16.5       16.4    0.394     0.448



                                                                                        Pow er (dBm)      1-g SAR (W/kg)
RF Exposure               Dist.    Test               Freq.                                                                 Plot
               Mode                          Ch #.            Duty Cycle   Antenna   Tune-up
 Conditions              (mm)     Position           (MHz)                                       Meas.   Meas.     Scaled   No.
                                                                                       Limit

                                                                            ANT 1     16.5       16.5    0.440     0.532
              802.11ac
 Standalone                0       Rear      138     5690      82.72%                                                        3
               VHT80
                                                                            ANT 2     16.5       16.5    0.367     0.444



                                                                                        Pow er (dBm)      1-g SAR (W/kg)
RF Exposure               Dist.    Test               Freq.                                                                 Plot
               Mode                          Ch #.            Duty Cycle   Antenna   Tune-up
 Conditions              (mm)     Position           (MHz)                                       Meas.   Meas.     Scaled   No.
                                                                                       Limit

                                                                            ANT 1     16.5       16.4    0.272     0.339
              802.11ac
 Standalone                0       Rear      155     5775      82.72%                                                        4
               VHT80
                                                                            ANT 2     16.5       16.4    0.197     0.245




                                                   Page 20 of 24
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.:12857633 -S1V3                                                                                    Issue Date: 9/24/2019

10.3. Standalone SAR Test Exclusion Considerations & Estimated SAR
The 1-g and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation distances
≤ 50 mm are determined by:
[(max. power of channel, including tune-up tolerance, mW) / (min. test separation distance, mm)]·[√f(GHz)] ≤ 3.0, for 1-g SAR
and ≤ 7.5 for 10-g extremity SAR, where
    •    f(GHz) is the RF channel transmit frequency in GHz
    •    Power and distance are rounded to the nearest mW and mm before calculation
    •    The result is rounded to one decimal place for comparison
The test exclusions are applicable only when the minimum test separation distance is ≤ 50 mm and for
transmission frequencies between 100 MHz and 6 GHz. When the minimum test separation distance is < 5 mm, a
distance of 5 mm is applied to determine SAR test exclusion.

When the standalone SAR test exclusion is applied to an antenna that transmits simultaneously with other
antennas, the standalone SAR must be estimated according to following to determine simultaneous transmission
SAR test exclusion:
    •    (max. power of channel, including tune-up tolerance, mW) / (min. test separation distance, mm)]·[√f(GHz)/x] W/kg for test
         separation distances ≤ 50 mm;
                  where x = 7.5 for 1-g SAR, and x = 18.75 for 10-g SAR.
    •    0.4 W/kg for 1-g SAR and 1.0 W/kg for 10-g SAR, when the test separation distances is > 50 mm.


                                                    Max. tune-up tolerance          Min. test       SAR test        Estimated
     RF Air      RF Exposure      Frequency                 Pow er                 separation       exclusion       1-g SAR
   interface      Conditions        (GHz)
                                                     (dBm)           (mW)        distance (mm)       Result*         (W/kg)
   Bluetooth      Standalone         2.480            6.0              4                5              1.3            0.168

Conclusion:
*: The computed value is ≤ 3; therefore, this qualifies for Standalone SAR test exclusion.




                                                   Page 21 of 24
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.:12857633 -S1V3                                                                          Issue Date: 9/24/2019

11.     SAR Measurement Variability
In accordance with published RF Exposure KDB 865664 D01 SAR measurement 100 MHz to 6 GHz. These
additional measurements are repeated after the completion of all measurements requiring the same head or body
tissue-equivalent medium in a frequency band. The test device should be returned to ambient conditions (normal
room temperature) with the battery fully charged before it is re-mounted on the device holder for the repeated
measurement(s) to minimize any unexpected variations in the repeated results.

1) Repeated measurement is not required when the original highest measured SAR is <0.8 or 2 W/kg (1-g or 10-g
   respectively); steps 2) through 4) do not apply.
2) When the original highest measured SAR is ≥ 0.8 or 2 W/kg (1-g or 10-g respectively), repeat that
   measurement once.
3) Perform a second repeated measurement only if the ratio of largest to smallest SAR for the original and first
   repeated measurements is > 1.20 or when the original or repeated measurement is ≥ 1.45 or 3.6 W/kg (~ 10%
   from the 1-g or 10-g respective SAR limit).
4) Perform a third repeated measurement only if the original, first, or second repeated measurement is ≥ 1.5 or
   3.75 W/kg (1-g or 10-g respectively) and the ratio of largest to smallest SAR for the original, first and second
   repeated measurements is > 1.20.

Note(s):
Repeated measurement is not required since the original highest measured SAR is <0.8 W/kg (1-g).




                                                   Page 22 of 24
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.:12857633 -S1V3                                                                                            Issue Date: 9/24/2019

12.      Simultaneous Transmission SAR Analysis
Simultaneous Transmission Condition
                                                 Capable Transmit Configurations
  RF Exposure Condition      Item
                                                ANT 1                             ANT 2
                              1                 DTS                 +             DTS
         Standalone           2                 U-NII               +             U-NII
                              3             BT & U-NII              +             U-NII
Notes:
    1. Bluetooth Radio is only supported on ANT 1.
    2.  DTS Radio cannot transmit simultaneously w ith Bluetooth Radio on ANT1.
    3.  U-NII Radio can transmit simultaneously w ith Bluetooth Radio.



12.1. Sum of the SAR for Wi-Fi & BT
                                        Standalone SAR (W/kg)                                     ∑ 1-g SAR (W/kg)
    RF
               Test               DTS                     U-NII
 Exposure                                                                  BT        DTS + DTS      U-NII + U-NII    U-NII + BT
              Position
 Conditions               ANT 1         ANT 2     ANT 1           ANT 2   ANT 1
                                                                                      ① +②            ③ +④          ③ +④ +⑤
                           ①             ②         ③               ④       ⑤
 Standalone    Rear       0.411         0.342     0.627           0.448   0.168           0.753        1.075           1.243




                                                   Page 23 of 24
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.


Report No.:12857633 -S1V3                                                                        Issue Date: 9/24/2019
                                                     Figure (1)

Appendixes
Refer to separated files for the following appendixes.

Appendix A: SAR Setup Photos

Appendix B: SAR System Check Plots

Appendix C: SAR Highest Test Plots

Appendix D: SAR Tissue Ingredients

Appendix E: SAR Probe Certificates

Appendix F: SAR Dipole Certificates



                                                END OF REPORT




                                                   Page 24 of 24
UL Verification Services Inc.                                                                             Doc. No.: 1.0
           This report shall not be reproduced without the written approval of UL Verification Services Inc.



Document Created: 2019-10-03 01:53:59
Document Modified: 2019-10-03 01:53:59

© 2024 FCC.report