S-156-FCCISED-MPE-2

FCC ID: C3K1843

RF Exposure Info

Download: PDF
FCCID_4278987

         MPE TEST REPORT
                       For

             MODEL NO.: 1843
             FCC ID: C3K1843
             IC ID: 3048A-1843

     Test Report No. S-156-FCCISED-MPE-2
            Issue Date: May 6, 2019

   FCC 47CFR Parts 1.1307, 1.1310, 2.1091
Innovation, Science and Economic Development
            Canada RSS-102 Issue 5


                 Prepared by
           Microsoft EMC Laboratory
              17760 NE 67th Ct,
          Redmond WA, 98052, U.S.A.
                425-421-9799
            sajose@microsoft.com




              TESTING CERT #3472.01




                                               Rev 2.0


                                                                            FCC ID: C3K1843
                                                                           IC ID: 3048A-1843

1 Record of Revisions
 Revision   Date         Section Page(s)    Summary of Changes             Author/Revised
                                                                           By:
 1.0        04/30/2019   All     All         Version 1.0                   Z. Gray
 2.0        05/06/2019   4       6          Added 160 MHz BW to radio      Z. Gray
                                            description, extended WLAN
                                            frequency range to 2472 MHz.




Report#: S-156-FCCISED-MPE-2      Issued: May 6, 2019                           Page 2 of 13
                                 Microsoft EMC Laboratory


                                                                                                                    FCC ID: C3K1843
                                                                                                                   IC ID: 3048A-1843




Table of Contents
1     Record of Revisions ............................................................................................................ 2
2     Deviations from Standards .................................................................................................. 5
3     Facilities and Accreditations ................................................................................................ 5
    3.1     Test Facility.................................................................................................................. 5
    3.2     Accreditations .............................................................................................................. 5
4     Product Description............................................................................................................. 6
5     MPE Requirements ............................................................................................................. 7
    5.1     FCC MPE Requirements.............................................................................................. 7
                  FCC RF Exposure Exemption Criteria .................................................................. 7
    5.2     ISED MPE Requirements............................................................................................. 9
                  ISED MPE Exemption Requirements from RSS-102 Section 2.5.2 ....................... 9
6     Maximum Device EIRP and ERP .......................................................................................10
7     Evaluation Against Exemption Criteria for RF Exposure Evaluation ...................................11
8     MPE Calculations and Evaluation ......................................................................................12




Report#: S-156-FCCISED-MPE-2                         Issued: May 6, 2019                                                   Page 3 of 13
                                                  Microsoft EMC Laboratory


                                                                                           FCC ID: C3K1843
                                                                                          IC ID: 3048A-1843


                      Test Report Attestation
                                          Microsoft Corporation
                                               Model: 1843
                                            FCC ID: C3K1843
                                          ISED ID: 3048A-1843


Applicable Standards
         Specification                                                                 Test Result
 FCC CFR47 Rule Parts 1.1307, 1.1310, 2.1091                                                Pass

 ISED RSS-102 Issue 5                                                                       Pass



Microsoft EMC Laboratory attests that the product model identified in this report has been tested to and
meets the requirements identified in the above standards. The test results in this report solely pertains to
the specific sample tested, under the conditions and operating modes as provided by the customer.

This test report replaces the previously issued report #S-156-FCCISED-MPE-1 issued by Microsoft EMC
Labs.
This report shall not be used to claim product certification, approval, or endorsement by A2LA or any
agency of any Government. Reproduction, duplication or publication of extracts from this test report is
prohibited and requires prior written approval of Microsoft EMC Laboratory.




 Written By: Zack Gray                                Reviewed/ Issued By: Daniel Salinas
 SAR Test Lead                                        Radio Test Lead




Report#: S-156-FCCISED-MPE-2             Issued: May 6, 2019                                    Page 4 of 13
                                       Microsoft EMC Laboratory


                                                                            FCC ID: C3K1843
                                                                           IC ID: 3048A-1843

2 Deviations from Standards
 None.
3 Facilities and Accreditations
3.1 Test Facility
 All test facilities used to collect the test data are located at
 Microsoft EMC Laboratory,
 17760 NE 67th Ct,
 Redmond WA, 98052, USA

3.2 Accreditations
 The lab is established and follows procedures as outlined in IEC/ISO 17025 and A2LA
 accreditation requirements.
 A2LA Accredited Testing Certificate Number: 3472.01
 FCC Registration Number: US1141
 IC Site Registration Numbers: 3048A-3, 3048A-4




Report#: S-156-FCCISED-MPE-2           Issued: May 6, 2019                      Page 5 of 13
                                     Microsoft EMC Laboratory


                                                                           FCC ID: C3K1843
                                                                          IC ID: 3048A-1843

4 Product Description
 Company Name:            Microsoft Corporation

 Address:                 One Microsoft Way

 City, State, Zip:        Redmond, WA 98052-6399

 Customer Contact:        Choon Ooi

 Functional Description of
 the EUT:                  Smart Display

 RF Exposure Conditions: Mobile Exposure Conditions (Separation distance of ≥ 20 cm)

 Model:                   1843

 FCC ID:                  C3K1843

 IC ID:                   3048A-1843
                          WLAN Main 2.4 GHz: 802.11 b/g/n - 20/40 MHz BW’s
                          WLAN Main 5 GHz: 802.11 a/n/ac - 20, 40, 80, 160 MHz
 Radio Descriptions:      Bluetooth™ (Basic and Enhanced Data Rates) / Bluetooth LE
                          Doppler Radar

                                                  2412 – 2472 MHz
                          WLAN:
                                                  5180 – 5825 MHz
 Frequency Range of
 Operation:               BT / BTLE:              2402 – 2480 MHz
                          Doppler:                24.15 – 24.25 GHz
                          WLAN: CCK, BPSK, QPSK, 16-QAM, 64-QAM, 256-QAM
 Modulations:                              𝝅
                          Bluetooth: GFSK, πŸ’ DQPSK, and 8 DPSK
                          Radio                   Band                Chain 1    Chain 2
                          WLAN                    2412 – 2472 MHz     7 dBi      5.3 dBi
                                                  5180 – 5240 MHz     4.7 dBi    4.2 dBi
                                                  5260 – 5320 MHz     5 dBi      4.7 dBi
 Antenna Peak Gains:                              5500 – 5700 MHz     4.9 dBi    4.5 dBi
                                                  5745 – 5825 MHz     4.3 dBi    3.6 dBi
                          BT / BTLE:              2402 – 2480 MHz     3.6 dBi
                          Doppler Radar:          24.15 – 24.25 GHz   4 dBi

 EUT Classification:      UNII, DTS, FHSS

 Equipment Design State: Prototype/Production Equivalent

 Equipment Condition:     Good




Report#: S-156-FCCISED-MPE-2       Issued: May 6, 2019                          Page 6 of 13
                                  Microsoft EMC Laboratory


                                                                                FCC ID: C3K1843
                                                                               IC ID: 3048A-1843

5 MPE Requirements
5.1 FCC MPE Requirements
The FCC MPE limits from CFR 47 Part 1.1310 are shown in the table below.

   Frequency          Electric field          Magnetic field         Power         Averaging
     range              strength                strength            density          time
     (MHz)                (V/m)                   (A/m)            (mW/cm2)        (minutes)
                      (A) Limits for Occupational/Controlled Exposure
0.3-3.0                    614                     1.63               *100              6
3.0-30                    1842/f                   4.89/f            *900/f2            6
30-300                     61.4                    0.163               1.0              6
300-1,500                                                             f/300             6
1,500-100,000                                                           5               6
                  (B) Limits for General Population/Uncontrolled Exposure
0.3-1.34                   614                     1.63               *100             30
1.34-30                    824/f                   2.19/f            *180/f2           30
30-300                     27.5                    0.073               0.2             30
300-1,500                                                            f/1500            30
1,500-100,000                                                          1.0             30

          FCC RF Exposure Exemption Criteria
The exemption criteria for RF exposure evaluation from CFR 47 Part 2.1091(c) are as follows:

(c)(1) Mobile devices that operate in the Commercial Mobile Radio Services pursuant to part 20
of this chapter; the Cellular Radiotelephone Service pursuant to part 22 of this chapter; the
Personal Communications Services pursuant to part 24 of this chapter; the Satellite
Communications Services pursuant to part 25 of this chapter; the Miscellaneous Wireless
Communications Services pursuant to part 27 of this chapter; the Maritime Services (ship earth
station devices only) pursuant to part 80 of this chapter; the Specialized Mobile Radio Service,
and the 3650 MHz Wireless Broadband Service pursuant to part 90 of this chapter; and the
Citizens Broadband Radio Service pursuant to part 96 of this chapter are subject to routine
environmental evaluation for RF exposure prior to equipment authorization or use if:

(i) They operate at frequencies of 1.5 GHz or below and their effective radiated power (ERP) is
1.5 watts or more, or

(ii) They operate at frequencies above 1.5 GHz and their ERP is 3 watts or more.




Report#: S-156-FCCISED-MPE-2           Issued: May 6, 2019                           Page 7 of 13
                                   Microsoft EMC Laboratory


                                                                                 FCC ID: C3K1843
                                                                                IC ID: 3048A-1843

(2) Unlicensed personal communications service devices, unlicensed millimeter wave devices
and unlicensed NII devices authorized under §§15.253(f), 15.255(g), 15.257(g), 15.319(i), and
15.407(f) of this chapter are also subject to routine environmental evaluation for RF exposure
prior to equipment authorization or use if their ERP is 3 watts or more or if they meet the
definition of a portable device as specified in §2.1093(b) requiring evaluation under the
provisions of that section.

(3) All other mobile and unlicensed transmitting devices are categorically excluded from routine
environmental evaluation for RF exposure prior to equipment authorization or use, except as
specified in §§1.1307(c) and 1.1307(d) of this chapter.




Report#: S-156-FCCISED-MPE-2         Issued: May 6, 2019                             Page 8 of 13
                                   Microsoft EMC Laboratory


                                                                                  FCC ID: C3K1843
                                                                                 IC ID: 3048A-1843

5.2 ISED MPE Requirements
The ISED MPE limits from RSS-102 Issue 5 are shown in the table below.

              RF Field Strength Limits for Devices Used by the General Public
                                  (Uncontrolled Environment)

   Frequency           Electric Field        Magnetic             Power          Reference
  Range (MHz)            (V/m rms)             Field             Density           Period
                                             (A/m rms)                   2       (minutes)
                                                                  (W/m )
0.003-1021                    83                   90                   -         Instantaneous*
0.1-10                         -                   0.73/ ƒ              -              6**
1.1-10                        87/ ƒ 0.5             -                   -              6**
10-20                       27.46                  0.0728              2                6
20-48                      58.07/ ƒ 0.25      0.1540/ ƒ 0.25        8.944/ ƒ 0.5
                                                                                        6
48-300                      22.06                 0.05852            1.291              6
300-6000                  3.142 ƒ 0.3417      0.008335 ƒ         0.02619ƒ0.6834         6
                                                  0.3417
6000-15000                   61.4               0.163                  10               6
15000-150000                 61.4               0.163                  10           616000/ ƒ 1.2
150000-300000               0.158 ƒ 0.5      4.21 x 10-4 ƒ 0.5     6.67 x 10-5 ƒ    616000/ ƒ 1.2
   Note: ƒ is frequency in MHz.
   *Based on nerve stimulation (NS).
   ** Based on specific absorption rate (SAR).


       ISED MPE Exemption Requirements from RSS-102 Section 2.5.2
RF exposure evaluation is required if the separation distance between the user and/or
bystander and the device’s radiating element is greater than 20 cm, except when the device
operates as follows:

   •   below 20 MHz and the source-based, time-averaged maximum e.i.r.p. of the device is
       equal to or less than 1 W (adjusted for tune-up tolerance);
   •   at or above 20 MHz and below 48 MHz and the source-based, time-averaged maximum
       e.i.r.p. of the device is equal to or less than 22.48/ƒ0.5 W (adjusted for tune-up
       tolerance), where ƒ is in MHz;
   •   at or above 48 MHz and below 300 MHz and the source-based, time-averaged
       maximum e.i.r.p. of the device is equal to or less than 0.6 W (adjusted for tune-up
       tolerance);
   •   at or above 300 MHz and below 6 GHz and the source-based, time-averaged maximum
       e.i.r.p. of the device is equal to or less than 1.31 x 10-2 ƒ0.6834 W (adjusted for tune-up
       tolerance), where ƒ is in MHz;
   •   at or above 6 GHz and the source-based, time-averaged maximum e.i.r.p. of the device
       is equal to or less than 5 W (adjusted for tune-up tolerance).




Report#: S-156-FCCISED-MPE-2           Issued: May 6, 2019                            Page 9 of 13
                                     Microsoft EMC Laboratory


                                                                                 FCC ID: C3K1843
                                                                                IC ID: 3048A-1843

6 Maximum Device EIRP and ERP
The declared maximum output powers including tune-up tolerances are used in conjunction with
the maximum antenna gains to find the maximum EIRP and ERP values.

For transmitters with multiple transmit chains, total EIRP and total ERP are calculated as:

𝐸𝐼𝑅𝑃𝑇𝑂𝑇 = 𝐸𝐼𝑅𝑃1 + 𝐸𝐼𝑅𝑃2 + β‹― 𝐸𝐼𝑅𝑃𝑛

𝐸𝑅𝑃𝑇𝑂𝑇 (π‘‘π΅π‘š) = 𝐸𝐼𝑅𝑃𝑇𝑂𝑇 (π‘‘π΅π‘š) − 2.15 𝑑𝐡

                       Maximum EIRP and ERP of all Device Radios
 Radio          Band    Chain     Chain   Chain     Chain    Chain    Chain   Max        Max
                (GHz)   A         A       A         B        B        B       Total      Total
                        Max       Max     Max       Max      Max      Max     EIRP       ERP
                        Power     Gain    EIRP      Power    Gain     EIRP    (dBm)      (dBm)
                        (dBm)     (dBi)   (dBm)     (dBm)    (dBi)    (dBm)
 WLAN            2.4     17.5        7     24.5      17.5      5.3     22.8     26.74     24.59
 WLAN            5.2     17.5       4.7    22.2      17.5      4.2     21.7     24.97     22.82
                 5.3     17.5        5     22.5      17.5      4.7     22.2     25.36     23.21
                 5.6     17.5       4.9    22.4      17.5      4.5      22      25.21     23.06
                 5.8     17.5       4.3    21.8      17.5      3.6     21.1     24.47     22.32
 BT / BLE        2.4       5        3.6     8.6                                  8.6      6.45
 Doppler
                24.25      6        4       10                                  10.0      7.85
 Radar




Report#: S-156-FCCISED-MPE-2         Issued: May 6, 2019                             Page 10 of 13
                                   Microsoft EMC Laboratory


                                                                             FCC ID: C3K1843
                                                                            IC ID: 3048A-1843

7 Evaluation Against Exemption Criteria for RF Exposure Evaluation

      Evaluation of Device Radios Against FCC and ISED Exemption Criteria
 Radio /        Band    Max      FCC       FCC     Max Total        ISED          ISED
 Rulepart       (GHz)   Total    Exemption Exempt? EIRP             Exemption     Exempt?
                        ERP      ERP               (mW)             EIRP
                        (mW)     Limits                             Limits
                                 (mW)                               (mW)
 WLAN 15.247      2.4   287.94       NA      Yes1   472.38            2702.91        Yes
 WLAN 15.407      5.2   191.32      3000     Yes    313.87            4560.23        Yes
                  5.3   209.55      3000     Yes    343.79            4608.31        Yes
                  5.6   202.53      3000     Yes    332.27            4751.18        Yes
                  5.8   170.78      3000     Yes    280.18            4895.01        Yes
  BT / BLE        2.4    4.42        NA      Yes1    7.24             4560.23        Yes
  15.247
  Doppler        24.25     6.10       NA         Yes1       10.00      2702.91        Yes
  Radar 15.249
1
 Since 2.1091(c) does not reference Part 15.247 or 15.249, Bluetooth, WLAN 2.4 GHz and
Doppler radios are categorically exempted from routine RF exposure evaluation by Part
1.1091(c)(3).

All Radios are exempt from routine RF Exposure Evaluation for both FCC and ISED.




Report#: S-156-FCCISED-MPE-2       Issued: May 6, 2019                          Page 11 of 13
                                  Microsoft EMC Laboratory


                                                                                     FCC ID: C3K1843
                                                                                    IC ID: 3048A-1843

8 MPE Calculations and Evaluation
Power densities are calculated for all radios, and the sum totals are compared to the FCC and
ISED limits to support the 20 cm minimum device-user separation distance.

Power density is calculated as:

                                                   𝐸𝐼𝑅𝑃
                                           𝑆=
                                                   πœ‹π‘… 2
For FCC, the power densities of all radios are calculated and summed to show that the worst
case is less than the corresponding power density limits.

                                 MPE Power Density Evaluation at 20cm
 Antenna       Band     Max       Max    S       FCC      FCC      S          ISED            𝑆     ISED
               (GHz)    EIRP      EIRP    π‘šπ‘Š     Limit    Result    π‘Š         Limit         πΏπ‘–π‘šπ‘–π‘‘   Result
                                         ( 2)     π‘šπ‘Š               ( 2)           π‘Š
                        (dBm)     (mW)    π‘π‘š                        π‘š
                                                 ( 2)                         (        )
                                                        π‘π‘š                        π‘š2
 WLAN          2.4       26.74    472.38    0.38        1.0   Pass    3.76        5.37      0.70     Pass
 WLAN          5.2       24.97    313.87    0.25        1.0   Pass    2.50        9.05      0.28     Pass
               5.3       25.36    343.79    0.27        1.0   Pass    2.74        9.14      0.30     Pass
               5.6       25.21    332.27    0.26        1.0   Pass    2.64        9.43      0.28     Pass
               5.8       24.47    280.18    0.22        1.0   Pass    2.23        9.71      0.23     Pass
 BT / BLE      2.4       8.60      7.24     0.01        1.0   Pass    0.06        5.37      0.01     Pass
 Doppler
               24.25     10.00     10.00    0.01        1.0   Pass    0.08        10        0.01     Pass
 Radar

 Total                            489.62    0.40        1.0   Pass                          0.72     Pass


   •     Since all FCC Bands have the same limit, Max EIRP and power densities are summed
         and the sum is compared to the FCC MPE limit.
   •     For FCC evaluation, the WLAN band with the highest EIRP is chosen for the worst-case
         total since the device can only transmit in one WLAN band at a time.

   •     ISED limits for 300 – 6000 MHz are calculated as (from table in section 5.2):
                                                   π‘Š
                𝐼𝑆𝐸𝐷 πΏπ‘–π‘šπ‘–π‘‘ = 0.02619 ∗ 𝑓 0.6834
                                                   π‘š2


   •     For ISED in accordance with RSS-102 Section 3.2, the fractions of the applicable limits
         are summed and the sum shown to be below 1 since the limits differ by band.
   •     For ISED evaluation, The WLAN band with the highest fraction of the applicable limit is
         chosen for the worst-case total since the device can only transmit in one WLAN band at
         a time.




Report#: S-156-FCCISED-MPE-2           Issued: May 6, 2019                                 Page 12 of 13
                                      Microsoft EMC Laboratory


                                                           FCC ID: C3K1843
                                                          IC ID: 3048A-1843




                         End of Report




Report#: S-156-FCCISED-MPE-2    Issued: May 6, 2019           Page 13 of 13
                               Microsoft EMC Laboratory



Document Created: 2019-05-15 18:33:23
Document Modified: 2019-05-15 18:33:23

Β© 2024 FCC.report