11600175-S1V1 SAR_App E Probe Cal. Certificates

FCC ID: C3K1796

RF Exposure Info

Download: PDF
FCCID_3390165

Calibration Laboratory of                                                ul  vph


                                                                                                                S   Schweizerischer Kalibrierdienst




                                                                  /I,/




                                                              )K                    88
Schmid & Partner




                                                                                        wo
                                                                  ty
                                                                                                                    Service suisse d‘étalonnage
   Engineering AG
                                                                                                                C
                                                                                                                    Servizio svizzero di taratura
                                                                                                                S




                                                                                   /"/,,,
                                                                   w
Zeughausstrasse 43, 8004 Zurich, Switzerland                                                                        Swiss Calibration Service
                                                                         ”/"/nlu\“\\\


Accredited by the Swiss Accreditation Service (SAS)                                                             Accreditation No.: SCS 0108
The Swiss Accreditation Service is one of the signatories to the EA
Multilateral Agreement for the recognition of calibration certificates

Client       UL CCS USA                                                                               Certificate No: EX3—3991_May16


CALIBRATION CERTIFICATE
 Object                               EX3DV4 — SN:3991

 Calibration procedure(s)             QA CAL—01.v9, QA CAL—14.v4, QA CAL—23.v5, QA CAL—25.v6
                                      Calibration procedure for dosimetric E—field probes



 Calibration date:                    May 12, 2016

 This calibration certificate documents the traceability to national standards, which realize the physical units of measurements (S1).
 The measurements and the uncertainties with confidence probability are given on the following pages and are part of the certificate.


 All calibrations have been conducted in the closed laboratory facility: environment temperature (22 + 3)°C and humidity < 70%.


 Calibration Equipment used (M&TE critical for calibration)



 Primary Standards                   ID                                      Cal Date (Certificate No.)                Scheduled Calibration
  Power meter NRP                    SN: 104778                              06—Apr—16 (No. 217—02288/02289)           Apr—17
  Power sensor NRP—291               SN: 103244                              06—Apr—16 (No. 217—02288)                 Apr—17
|_Power sensor NRP—291               SN: 103245                              06—Apr—16 (No. 217—02289)                 Apr—17
  Reference 20 dB Attenuator         SN: $5277 (20x%)                        05—Apr—16 (No. 217—02293)                 Apr—17
  Reference Probe ES3DV2             SN: 3013                                31—Dec—15 (No. ES3—3013_Dec15)            Dec—16
  DAE4                               SN: 660                                 23—Dec—15 (No. DAE4—660_Dec15)            Dec—16

  Secondary Standards                ID                                      Check Date (in house)                     Scheduled Check
  Power meter E4419B                 SN: GB41293874                          06—Apr—16 (No. 217—02285/02284)           In house check: Jun—16
  Power sensor E4412A                SN: MY41498087                          06—Apr—16 (No. 217—02285)                 In house check: Jun—16
  Power sensor E4412A                SN: 000110210                           06—Apr—16 (No. 217—02284)                  In house check: Jun—16
  RF generator HP 8648C              SN:; US3642U01700                       04—Aug—99 (in house check Apr—13)        | In house check: Jun—16
  Network Analyzer HP 8753E          SN: US37390585                          18—Oct—01 (in house check Oct—15)        ] In house check: Oct—16

                                          Name                                          Function
 Calibrated by:                           Claudio Leubler                               Laboratory Technician




 Approved by:                             Katja Pokovic                               Technical Manager

                                                                                                                     LEATIssued: May 19, 2016
 This calibration certificate shall not be reproduced except in full without written approval of the laboratory.




Certificate No: EX3—3991_May16                                             Page 1 of 11


Calibration
      .     Laboratory of                                                                S    Schweizerischer Kalibrierdienst
Schmid & Partner                                                                         _    Service suisse d‘étalonnage
  Engineering AG                                                                         5    Servizio svizzero di taratura
Zeughausstrasse 43, 8004 Zurich, Switzerland                                                  Swiss Calibration Service



Accredited by the Swiss Accreditation Service (SAS)                                        Accreditation No.: SCS 0108
The Swiss Accreditation Service is one of the signatories to the EA
Multilateral Agreement for the recognition of calibration certificates

Glossary:
TSL                          tissue simulating liquid
NORMx,y,z                    sensitivity in free space
Convr                        sensitivity in TSL / NORMx,y,z
DCP                          diode compression point
CF                           crest factor (1/duty_cycle) of the RF signal
A, B, C, D                   modulation dependent linearization parameters
Polarization o               @ rotation around probe axis
Polarization 8               8 rotation around an axis that is in the plane normal to probe axis (at measurement center),
                             ie., 8 = 0 is normal to probe axis
Connector Angle              information used in DASY system to align probe sensor X to the robot coordinate system

Calibration is Performed According to the Following Standards:
         IEEE Std 1528—2013, "IEEE Recommended Practice for Determining the Peak Spatial—Averaged Specific
         Absorption Rate (SAR) in the Human Head from Wireless Communications Devices: Measurement
         Techniques", June 2013
         IEC 62209—1, "Procedure to measure the Specific Absorption Rate (SAR) for hand—held devices used in close
         proximity to the ear (frequency range of 300 MHz to 3 GHz)", February 2005
         IEC 62209—2, "Procedure to determine the Specific Absorption Rate (SAR) for wireless communication devices
         used in close proximity to the human body (frequency range of 30 MHz to 6 GHz)", March 2010
    d)   KDB 865664, "SAR Measurement Requirements for 100 MHz to 6 GHz"

Methods Applied and Interpretation of Parameters:
         NORMx,y,z: Assessed for E—field polarization 8 = 0 (f < 900 MHz in TEM—cell; f > 1800 MHz: R22 waveguide).
         NORMx,y,z are only intermediate values, i.e., the uncertainties of NORMx,y,z does not affect the E"—field
         uncertainty inside TSL (see below ConvF).
         NORM(PM)x,y,z = NORMx,y,z * frequency_response (see Frequency Response Chart). This linearization is
         implemented in DASY4 software versions later than 4.2. The uncertainty of the frequency response is included
         in the stated uncertainty of ConvF.
         DCPx,y,z: DCP are numerical linearization parameters assessed based on the data of power sweep with CW
         signal (no uncertainty required). DCP does not depend on frequency nor media.
         PAR: PAR is the Peak to Average Ratio that is not calibrated but determined based on the signal
         characteristics
         Ax,y.z; Bx,y,z; Cx,.y,z; Dx,y,z; VRx,y,z; A, B, C, D are numerical linearization parameters assessed based on
         the data of power sweep for specific modulation signal. The parameters do not depend on frequency nor
         media. VR is the maximum calibration range expressed in RMS voltage across the diode.
         ConvrF and Boundary Effect Parameters: Assessed in flat phantom using E—field (or Temperature Transfer
         Standard for f < 800 MHz) and inside waveguide using analytical field distributions based on power
         measurements for f > 800 MHz. The same setups are used for assessment of the parameters applied for
         boundary compensation (alpha, depth) of which typical uncertainty values are given. These parameters are
         used in DASY4 software to improve probe accuracy close to the boundary. The sensitivity in TSL corresponds
         to NORMx,y,z * ConvF whereby the uncertainty corresponds to that given for ConvF. A frequency dependent
         ConvF is used in DASY version 4.4 and higher which allows extending the validity from + 50 MHz to + 100
         MHz.
         Spherical isotropy (3D deviation from isotropy): in a field of low gradients realized using a filat phantom
         exposed by a patch antenna.
         Sensor Offset: The sensor offset corresponds to the offset of virtual measurement ceriter from the probe tip
         {on probe axis). No tolerance required.
         Connector Angle: The angle is assessed using the information gained by determining the NORMx (no
         uncertainty required).


Certificate No: EX3—3991_May16                                  Page 2 of 11


EX3DV4 — SN:3991                                                                May 12, 2016




                     Probe EX3DV4

                                         SN:3991

                                  Manufactured:             January 21, 2014
                                  Repaired:                 May 3, 2016
                                  Calibrated:               May 12, 2016



                                 Calibrated for DASY/EASY Systems
                                    (Note: non—compatible with DASY2 system!)




Certificate No: EX3—3991_May16                     Page 3 of 11


EX3DV4— SN:3991                                                                                                                  May 12, 2016



DASY/EASY — Parameters of Probe: EX3DV4 — SN:3991
Basic Calibration Parameters
                                                Sensor X                          Sensor Y                   Sensor Z             Unc (k=2)
 Norm (uV/(V/m)")*                                0.42                             0.44                        0.46               +101 %
 DCP (mVv)"                                       100.2                            100.7                       104.5

Modulation Calibration Parameters
 UID     Communication System Name                                           A           B          C           D         VR           Unc®
                                                                            dB        dBv/‘uV                  dB         mV           (k=2)
 0             CW                                                 xX        0.0         0.0         1.0       0.00       149.9        +3.3 %
                                                                  Y         0.0         0.0         1.0                  132.3
                                                                  Z         0.0         0.0         1.0                  132.7


 The reported uncertainty of measurement is stated as the standard uncertainty of measurement
 multiplied by the coverage factor k=2, which for a normal distribution corresponds to a coverage
 probability of approximately 95%.


* The uncertainties of Norm X,Y,Z do not affect the E*—field uncertainty inside TSL (see Pages 5 and 6).
  Numerical linearization parameter: uncertainty not required.
* Uncertainty is determined using the max. deviation from linear response applying rectangular distribution and is expressed for the square of the
field value.




Certificate No: EX3—3991_May16                                         Page 4 of 11


EX3DV4— SN:3991                                                                                                                 May 12, 2016




DASY/EASY — Parameters of Probe: EX3DV4 — SN:3991


Calibration Parameter Determined in Head Tissue Simulating Media
               $        Relative _       Conductivity                                                            o   Depth ®           Unc          ’
     f (MHz)         Permittivity            (S/m)              ConvF X    ConvF Y        ConvFZ        Alpha          (mm)           (k=2)         |

        750               319                 0.89               10.21       10.21          10.21         0.49         0.80         + 12.0 %        j

        900               41.5                0.97               9.59         9.59          9.59          0.33         1.03         + 12.0 %            |

       1750               40.1                1.37               8.75         8.75          8.75          0.44         0.80         + 12.0 %

       1900               40.0                1.40               8.41         8.41          8.41          0.38         0.80         + 12.0 %

       2300               395                 1.67               7.88         7.88          7.88          0.36         0.80         £+12.0 %

       2450               39.2                1.80               7.58         7.58          7.58          0.37         0.80         + 12.0 %

       2600               39.0                1.96               7.24         7.24          7.24          0.41         0.83         +12.0 %

       5250               35.9                4.71               5.27         5.27           5.27         0.40         1.80         +13.1 %

       5600               2906                5.07               4.52         4.52          4.52          0.45          1.80        + 13.1 %

       5750               35.4                5.22               4.75         4.75           4.75         0.45          1.80        *13.1 %



© Frequency validity above 300 MHz of + 100 MHz only applies for DASY v4.4 and higher (see Page 2), else it is restricted to + 50 MHz. The
uncertainty is the RSS of the ConvF uncertainty at calibration frequency and the uncertainty for the indicated frequency band. Frequency validity
below 300 MHz is + 10, 25, 40, 50 and 70 MHz for ConvF assessments at 30, 64, 128, 150 and 220 MHz respectively. Above 5 GHz frequency
validity can be extended to + 110 MHz.
" At frequencies below 3 GHz, the validity of tissue parameters (e and o) can be relaxed to + 10% if liquid compensation formula is applied to
measured SAR values. At frequencies above 3 GHz, the validity of tissue parameters (s and 0) is restricted to + 5%. The uncertainty is the RSS of
the ConvF uncertainty for indicated target tissue parameters.
© Alpha/Depth are determined during calibration. SPEAG warrants that the remaining deviation due to the boundary effect after compensation is
always less than + 1% for frequencies below 3 GHz and below + 2% for frequencies between 3—6 GHz at any distance larger than half the probe tip
diameter from the boundary.




Certificate No: EX3—3991_May16                                      Page 5 of 11


EX3DV4— SN:3991                                                                                                                  May 12, 2016




DASY/EASY — Parameters of Probe: EX3DV4 — SN:3991


Calibration Parameter Determinged in Body Tissue Simulating Media
   |                    Relative         Conductivity                                                                 Depth °           Unc
       f(MHz)©       Permittivity®           (S/im)"         ConvFX         ConvFY        ConvFZ         Alpha®        (mm)            (k=2)
        750               55.5                0.96             10.04         10.04          10.04          0.42         0.91        +12.0 %
        900               55.0                1.05              9.67          9.67           9.67          0.46         0.87        £12.0 %
        1750              53.4                1.49              8.22          8.22           8.22          0.40         0.80        +12.0 %
        1900              53.3                1.52              7.99          7.99           7.99          0.35         0.80        +12.0 %
        2300              52.9                1.81              7.77          7.77           7.77          0.43         0.81        £12.0 %
        2450              52.7                1.95              7.65          7.65           7.65          0.39         0.80        +12.0 %
        2600              52.5                216               7.22          7.22           7.22          0.30         0.95        +12.0 %
        5250              48.9                5.36         |___4.54           4.54           4.54          0.50         1.90        *13.1 %
        5600              48.5                5.77              3.77          3.77           3.77          0.55         1.90         +131 %
        5750              48.3                5.94              4.03          4.03           4.03          0.55         1.90         +13.1 %


9 Frequency validity above 300 MHz of + 100 MHz only applies for DASY v4.4 and higher (see Page 2), else it is restricted to + 50 MHz. The
uncertainty is the RSS of the ConvF uncertainty at calibration frequency and the uncertainty for the indicated frequency band. Frequency validity
below 300 MHz is + 10, 25, 40, 50 and 70 MHz for ConvF assessments at 30, 64, 128, 150 and 220 MHz respectively. Above 5 GHz frequency
validity can be extended to + 110 MHz.
" At frequencies below 3 GHz, the validity of tissue parameters (s and 0) can be relaxed to + 10% if liquid compensation formula is applied to
measured SAR values. At frequencies above 3 GHz, the validity of tissue parameters (s and 0) is restricted to + 5%. The uncertainty is the RSS of
the ConvF uncertainty for indicated target tissue parameters.
© Alpha/Depth are determined during calibration. SPEAG warrants that the remaining deviation due to the boundary effect after compensation is
always less than + 1% for frequencies below 3 GHz and below + 2% for frequencies between 3—6 GHz at any distance larger than half the probe tip
diameter from the boundary.




Certificate No: EX3—3991_May16                                     Page 6 of 11


EX3DV4— SN:3991                                                                                                                                                                      May 12, 2016


                                              Frequency Response of E—Field
                                                       (TEM—Cell:ifi110 EXX, Waveguide: R22)




                  & —fcccscecervovenresnerencbrreerscenerrnrertrrrsasprenasceras08sr 28g6 i8991 ec9ice 480454 c48288t esb e se savanee Prrinasuarniferseense on e8 o0 00000 60099 0000 00



          ns A Bm{ommmmomansB$smmtmmmacftm§rameneSloe
          C              i                        §                        $                         f                        i                        :                         f
           O             y                        .                                                  &                        H                        1                         1
          .N
          o
                         :—                       ;                                                  f                        |                        E
                  12_L .....................:,...,.,.,........,...................“....,....i ....................... ;,............,.........,;...,.,......,..........,; ......
                                                                                                                                                                                 i

           S                                      :                        :                         :                        f                        s                         é
          g 1M                                        ............ Ponvive bn— qoarrernervesnensalt L,J

           80 0
           §
                         B             Cwps—~—_f
                  1.A epemsmmmosnncnnnnnnnneenbren en en en enc nnc cesEenrredrsererep———@———crerrisssageconnenc
                                                                                                               en nnnd en n
                                                                                                                              f                        f
           Q.            C                        i                                                  :                        $                        }                      ==p
           U             L                        i                                                  1                        1                        i                         1

           ® og_“ .............................................. pemmmmmna i eommmancrret ooo m
           6o 9P—                                 }
                                                                            fi                       |                        |                        ;                         ;
           5 To                                   o=mmseannle. }                                     $z m mm agfoonennensnnnrnnnrnmnnn femnnnnrngnnnnn en nn on d re e
           0             Cc                       ;                        i                         i                        $                        ;                         1
          $
          e
                     _E a         '           f            é            a                      é
                  oFar .foemcromm orrrem anall tcemerenenssfrreeeR ETE encnanrevvevenrenseraradycn en

                  G@Ammn(earmtratesformmmmmfnommmmmfan
                  0.5         0P        _fi    _   c    B    OA        O3



                                                             _@]
                                                             TEM
                                                                                                                                             *
                                                                                                                                             R22

                                             Uncertainty of Frequency Response of E—field: £ 6.3% (k=2)




Certificate No: EX3—3991_May16                                                            Page 7 of 11


ExX3DV4— SN:3991                                                                                                                                                                                                                                                                                                                May 12, 2016




                                                                                     Receiving Pattern (¢), 9 = 0°

                                        f=600 MHz,TEM                                                                                                                                                                     f=1800 MHz,R22

                                                                                                                                                                                                                                       wer"



                          135                                     *                  * N4z                                           45                                                              1350                                    t                      e                                              45
                                                      %                                      a~"t~—                                      *                                                            f                    *           *°                               a           —**                                M


                               »                                             &                                                   %                                                                                                                         ¥                                                   *

                           *                                                134                                                      »                                                               +                             *                   fo%                                [
                                                                                                         L           &                                                                                                                 %                                eA                    &
                                       w7 *               %            x\        i4 4*           &                           *                         1                                             *                »                       .‘    «5o> +                      &                      +
                                                                  * miff se#                                                                                                            i                     ¥                                    + N6o ..
            N4                     (                              " Ti                   Ds, ce                          q6              ‘os               $                        7                             &                         ye4*   . * L"02, 04                                       o6 o8                          *
                                             *~       6x                                     *                   ~                           t         f                                R                                  **~»—*                               |       * ~*                                           1

                  t                               *                          t                               »                                                                                                                     *                       ./                             9                        j


                                             s3                                              af.                     .s"                                                                                              x.                           2                Any             J         _—*

                          225                                     s.                  ye"                                    p3s                                                                     i#                                     rrg                     y           *                      «315


             ks                                               "~~~"yg—"~___                                                                            m                                    5                                          es
             G                                        e                                                  &                                             *                            4                                                  e                                            e                                                e
            Tot                                       X                                                  Y                                             Z                            Tot                                                X                                            Y                                                Z




      a.                                f;                                                                                                                                                                            ;
                                                                                                                                                                                                                                                                                                                           ;
                                                                                                                                                                                                                                                                                                                           ;
       ts                               M                                                                                                                                                                             P                                                                                                7
       C                                1                                                                                                                                                                             i                                                                                                    i
      ui                                5                                                                                                                                                                             |                                                                                                    |
       ks                               1                                                                                                                                                                             «                                                                                                    +




                 R    1         I;                T           M    1             1       E           1           L       T                                 |   T   1   _|   f   T   1           1         N           i’       1           |__4.       L                    1             1       N        T               ,f    |       T

                                   ,1%0                                              —100                                                        —éO                        0                                     50                                            100                                                    150
                                                 c                                                                                                _                     Roll [*]                        s                                                                                      2
                                                 » |                                                                                        * |                                                         # |                                                                                   *# |
                                             100   MHz                                                                                   600 MHz                                                    1800 MHz                                                                              2500 MHz


                                                                       Uncertainty of Axial Isotropy Assessment: £ 0.5% (k=2)




Certificate No: EX3—3991._May16                                                                                                                                Page 8 of 11


EX3DV4— SN:3991                                                                                                    May 12, 2016




                                            Dynamic Range f(SARneadq)
                                                      (TEM cell , fevai= 1990 MHz)




                            10°




                  _ 10‘ s
                  z>
                  &    n
                  g    [
                   C
                  .&                0| d                                                         PE O P l
                  [¥7
                   3—10%=£
                  E




                             10—




                             10!—}=
                                                T                       T    *
                                    103        102          10         10          101          10@           1(
                                                                  SAR {mW/icm3]
                                                      _*
                                              not compensated                       compensated
                       Error [dB]




                                     103        102         101          100      101      102              103
                                                                  SAR {mW/cm3]
                                                      _*]
                                               not compensated                    compensated


                                           Uncertainty of Linearity Assessment: £ 0.6% (k=2)




Certificate No: EX3—3991_May16                                    Page 9 of 11


EX3DV4— SN:3991                                                                                                                                                                                May 12, 2016


                                              Conversion Factor Assessment
                       f= 900 MHz,WGLS R9 (H_convF)                                                                 f = 1750 MHz,WGLS R22 (H_convF)

        s (»"t                                es t i                                                s                                  ben               . F
        354                                                                                               t                                                                                              f
              :"‘Il:                                                                                25— '\                                                                                               {
        s0 [ E\                                                                                                 \


      gel o\
      % 2.0
              >        C

                                   p
                                                                                               5*   zof '\\

                                                                                               Zé;' 15—
                                                                                                                    *        L‘\

      3                            N_                                                          $                                   NS
        15—                                   a                                                                                         *
              f                                   \"\\                                              10                                          C
         1 0{                                             fe ‘\\                                                                                    \\_\

              F                                                    Tr—                               5                                                     \\.\
        as                                                                    Preseg.                                                                                   SReulvs
              +                                                                                                                                                                         1 *rmeclsl _,‘
              I._._J_'_l_‘__;..                           §O2_LOE__TLL_TOSOO                                  L_L        1                      L                   1         fls        L_L4        11   ]
        i              5      10         15          20      25      30       35        40           &g              4                10            15       20          25        30          as        40
                             «;                    2 {mm}            3                                                               "«|                   z {mm}

                           analytcal                               measured                                                        analytical                                 measured



                                          Deviation from Isotropy in Liquid
                                                                       Error ($, 9), f = 900 MHz



                                   &
                                   .0
                                   6>
                                   &A .




                                       —1.0        —0.8      —0.6      —0.4        —0.2      0.0         02              0.4                 0.6         0.8            1.0
                                          Uncertainty of Spherical Isotropy Assessment: £ 2.6% (k=2)




Certificate No: EX3—3991_May16                                                       Page 10 of 11


EX3DV4— SN:3991                                              May 12, 2016




DASY/EASY — Parameters of Probe: EX3DV4 — SN:3991

Other Probe Parameteifs
 Sensor Arrangement                                          Triangular
 Connector Angle (°)                                                2.6
 Mechanical Surface Detection Mode                              enabled
 Optical Surface Detection Mode                                disabled
 Probe Overall Length                                           337 mm
 Probe Body Diameter                                             10 mm
 Tip Length                                                       9 mm
 Tip Diameter                                                   2.5 mm
 Probe Tip to Sensor X Calibration Point                          1 mm
~Probe Tip to Sensor Y Calibration Point                          1 mm
 Probe Tip to Sensor Z Calibration Point                          1 mm
 Recommended Measurement Distance from Surface                   1.4 mm




Certificate No: EX3—3991_May16               Page 11 of 11



Document Created: 2016-05-25 19:06:05
Document Modified: 2016-05-25 19:06:05

© 2024 FCC.report